Technical Specifications

This chapter contains the following sections:

Overview of Technical Specifications for IR1800 Series Routers

This chapter provides specifications for the IR1800.

Complete specifications for the IR1800 can be found in the marketing data sheet.

Router Specifications

The following table lists the specifications of the Cisco IR1800.

Description

Design Specification

Dimensions

11.00”W x 7.16” x 2.02”

Weight

2.4 kg (5.3 lb) (without any modules)

3.1 kg (6.8 lb) (fully configured)

Ingress Protection Rating

IP 40, IP54 with external kit attached.

Humidity

Noncondensing Relative Humidity: 5% to 95%

Standard Safety Certifications

UL/CSA 60950-1

UL/CSA/EN/IEC 62368-1

CB report and certificate to IEC 60950-1 with all country deviations

NOM to NOM-019-SCFI (through UL certificate of conformity)

ANSI/ISA 12.12.01 (Class l, Div 2, groups A-D)

CSA 22.2 No. 213-17

UL/CSA 60079-0, -7 (Class l, Zone 2, Gc/IIC)

IEC 60079-0, -7 IECEx test report (Class l, Zone 2, Gc/IIC)

EN 60079-0, -7 ATEX certifícate (Class l, Zone 2, Gc/IIC)

Operating Temperature and Altitude

-40C to +70C (40 lfm Vented Enclosure)

-40C to +60C (Sealed Enclosure)

-34C to +74C (Min. 200 lfm Fan or Blower Equipped Enclosure)

Altitude: up to 15,000 feet

Storage Temperature and Altitude

Temperature: -40 to +85 degrees C

Altitude: up to 15,000 feet

Input Voltage

Nominal voltage: 12V/24V (+/-20%)

Min/Max voltage: +9.6V to +36V DC input

Typical Current

5.5A

Typical/Maximum Power Consumption

65W

Thermal Mitigation

The following tables provide a description of thermal mitigation levels and throughput performance across all IoT industrial routers.

This applies to both the 4G LTE and 5G NR FR1 operation of the P-5GS6-GL.

Table 1. Thermal Mitigation Levels

Level

Description

Level 0

Normal mode, no thermal throttling.

Level 1

Uplink throttling, via reduced UL TX duty cycle.

Level 2

May include the following:

  • DL throughput capability reduction, such as 4 RX > 2 RX paths.

  • Drop Secondary Cells (SCells) all, or one by one.

  • 5G NR > 4G LTE fall back.

  • MTPL backoff or reduced TX power.

  • Reduced UL communication range.

Level 3

Limited service.

Note

 
Limited service typically means emergency calls only. The P-5GS6-GL does not support emergency call mode, therefore limited service means “no service” for the P-5GS6-GL .

Thermal Shutdown

This occurs after Level 3.


Note


Cisco does not recommend operation deep into level 2 as this may affect communication range via MTPL backoff.
Table 2. Thermal Mitigation Table - IR1835

Hardware

Maximum Ambient Temperature (C/F)

Airflow (LFM)

Throughput Performance

IR1835 plus WP-WIFI6 Dual P-5GS6-GL

60°/140°

0

Normal, Level 0

65°/149°

40

Normal, Level 0

70°/158°

40

Throttled, Level 1

70°/158°

200

Normal, Level 0

75°/167°

200

Throttled, Level 1