- Device Manager Help
- Configuring Cisco DCNM-SAN Server
- Configuring Authentication in Cisco DCNM-SAN
- Configuring Cisco DCNM-SAN Client
- Device Manager
- Configuring Performance Manager
- Configuring High Availability
- Configuring Trunking
- Configuring PortChannels
- Configuring N Port Virtualization
- Configuring Interfaces
- Configuration of Fibre Channel Interfaces
- Using the CFS Infrastructure
- Configuring SNMP
- Configuring Domain Parameters
- Configuring and Managing Zones
- Configuring FCoE
- Configuring Dense Wavelength Division Multiplexing
- Configuring and Managing VSANs
- Discovering SCSI Targets
- Configuring SAN Device Virtualization
- Configuring Fibre Channel Routing Services and Protocols
- Managing FLOGI, Name Server, FDMI, and RSCN Databases
- Configuring FICON
- Creating Dynamic VSANs
- Distributing Device Alias Services
- Configuring Advanced Fabric Features
- Configuring Users and Common Role
- Configuring Security Features on an External AAA Server
- Configuring Certificate Authorities and Digital Certificates
- Configuring FC-SP and DHCHAP
- Configuring Cisco TrustSec Fibre Channel Link Encryption
- Configuring FIPS
- Configuring IPv4 and IPv6 Access Control Lists
- Configuring IPsec Network Security
- Configuring Port Security
- Configuring Fabric Binding
- Configuring FCIP
- Configuring the SAN Extension Tuner
- Configuring iSCSI
- Configuring IP Services
- Configuring IP Storage
- Configuring IPv4 for Gigabit Ethernet Interfaces
- Configuring IPv6 for Gigabit Ethernet Interfaces
- Configuring SCSI Flow Services
- Configuring SCSI Flow Statistics
- Configuring Fibre Channel Write Acceleration
- Monitoring the Network
- Monitoring Performance
- Configuring Call Home
- Configuring System Message Logging
- Scheduling Maintenance Jobs
- Configuring RMON
- Configuring Fabric Configuration Server
- Monitoring Network Traffic Using SPAN
- Monitoring System Processes and Logs
- Configuring QoS
- Configuring Port Tracking
- Configuring FlexAttach Virtual pWWN
- Configuring Interface Buffers
- Verifying Ethernet Interfaces
- Information About RMON
- Default Settings
- Configuring RMON
- Configuring the RMON Traps in SNMP
- Configuring the RMON Alarm
- Configuring the RMON Event
- Enabling RMON Alarms by Port
- Enabling 32-Bit and 64-Bit Alarms
- Creating RMON Alarms
- Enabling 32-Bit RMON Alarms for VSANs
- Enabling 32-Bit and 64-Bit RMON Alarms for Physical Components
- Creating a New RMON from Device Manager Threshold Manager
- Managing RMON Events
- Managing RMON Alarms
- Viewing the RMON Log
- Verifying the RMON Configuration
- Field Descriptions for RMON
- Additional References
- Feature History for RMON
Configuring RMON
RMON is an Internet Engineering Task Force (IETF) standard monitoring specification that allows various network agents and console systems to exchange network monitoring data. You can use the RMON alarms and events to monitor Cisco MDS 9000 Family switches running the Cisco SAN-OS Release 2.0(1b) or later or Cisco NX-OS Release 4.1(3) or later software.
Information About RMON
RMON is disabled by default, and no events or alarms are configured in the switch.
All switches in the Cisco MDS 9000 Family support the following RMON functions (defined in RFC 2819):
- Alarm—Each alarm monitors a specific management information base (MIB) object for a specified interval. When the MIB object value exceeds a specified value (rising threshold), the alarm condition is set and only one event is triggered regardless of how long the condition exists. When the MIB object value falls below a certain value (falling threshold), the alarm condition is cleared. This allows the alarm to trigger again when the rising threshold is crossed again.
- Event—Determines the action to take when an event is triggered by an alarm. The action can be to generate a log entry, an SNMP trap, or both.
For agent and management information, see the Cisco MDS 9000 Family MIB Quick Reference.
For information on an SNMP-compatible network management station, see the “Configuring SNMP” section .
For SNMP security-related CLI configurations, see the “Information About SNMP Security” section.This section includes the following topics:
- RMON Configuration Information
- RMON Configuration Using Threshold Manager
- RMON Alarm Configuration Information
RMON Configuration Information
RMON is disabled by default and no events or alarms are configured in the switch. You can configure your RMON alarms and events by using the CLI or an SNMP-compatible network management station.
Tip We recommend an additional, generic RMON console application on the network management station (NMS) to take advantage of RMON's network management capabilities.
RMON Configuration Using Threshold Manager
RMON is disabled by default and no events or alarms are configured in the switch. You can configure your RMON alarms and events by using the CLI or by using Threshold Manager in Device Manager.
The Threshold Monitor allows you to trigger an SNMP event or log a message when the selected statistic goes over a configured threshold value. RMON calls this a rising alarm threshold. The configurable settings are as follows:
- Variable—The statistic you want to set the threshold value on.
- Value—The value of the variable that you want the alarm to trigger at. This value is the difference (delta) between two consecutive polls of the variable by Device Manager.
- Sample—The sample period (in seconds) between two consecutive polls of the variable. Select your sample period such that the variable does not cross the threshold value you set under normal operating conditions.
- Warning—The warning level used by Device Manager to indicate the severity of the triggered alarm. This is a DCNM-SAN and Device Manager enhancement to RMON.
Note To configure any type of RMON alarm (absolute or delta, rising or falling threshold) click More on the Threshold Manager dialog box. You should be familiar with how RMON defines these concepts before configuring these advanced alarm types. Refer to the RMON-MIB (RFC 2819) for information on how to configure RMON alarms.
Note You must also configure SNMP on the switch to access RMON MIB objects.
RMON Alarm Configuration Information
Threshold Manager provides a list of common MIB objects to set an RMON threshold and alarm on. The alarm feature monitors a specific MIB object for a specified interval, triggers an alarm at a specified value (rising threshold), and resets the alarm at another value (falling threshold).
You can also set an alarm on any MIB object. The specified MIB must be an existing SNMP MIB object in standard dot notation (1.3.6.1.2.1.2.2.1.14.16777216 16 16777216 for ifInOctets.167772161616777216).
Use one of the following options to specify the interval to monitor the MIB variable (ranges from 1 to 4294967295 seconds):
- Use the delta option to test the change between samples of a MIB variable.
- Use the absolute option to test each MIB variable directly.
- Use the delta option to test any MIB objects that are counters.
The range for the rising threshold and falling threshold values is -2147483647 to 2147483647.
Default Settings
Table 53-1 lists the default settings for all RMON features in any switch.
Configuring RMON
RMON is disabled by default, and no events or alarms are configured in the switch.
This section includes the following topics:
- Configuring the RMON Traps in SNMP
- Configuring the RMON Alarm
- Configuring the RMON Event
- Enabling RMON Alarms by Port
- Enabling 32-Bit and 64-Bit Alarms
- Creating RMON Alarms
- Enabling 32-Bit RMON Alarms for VSANs
- Enabling 32-Bit and 64-Bit RMON Alarms for Physical Components
- Creating a New RMON from Device Manager Threshold Manager
- Managing RMON Events
- Managing RMON Alarms
- Viewing the RMON Log
Prerequisites
You must enable the RMON traps in the SNMP configuration for the RMON configuration to function correctly.
To enable RMON traps in the SNMP configuration, follow these steps:
Note You must also configure SNMP on the switch to access RMON MIB objects.
Configuring the RMON Alarm
To enable RMON alarms, follow these steps:
Configuring the RMON Event
To enable RMON events, follow these steps:
Enabling RMON Alarms by Port
To configure an RMON alarm for one or more ports, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click the FC Interfaces tab.
You see the Threshold Manager dialog box.
Step 2 Choose the Select radio button to select individual ports for this threshold alarm.
a. Click the ... button to the right of the Selected field to display all ports.
b. Select the ports you want to monitor.
c. Click OK to accept the selection.
Alternatively, click the appropriate radio button to choose ports by type: All ports, xE ports, or Fx ports.
Step 3 Check the check box for each variable to be monitored.
Step 4 Enter the threshold value in the Value column.
Step 5 Enter the sampling period in seconds. This is the time between each snapshot of the variable.
Step 6 Choose one of the following severity levels to assign to the alarm: Fatal , Warning , Critical , Error , Information.
Step 8 Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event. If you do not confirm the operation, the system only defines a log event.
Step 9 Click More and then click the Alarms tab from the Threshold Manager dialog box to verify the alarm you created.
Step 10 Close both dialog box pop-up windows.
Enabling 32-Bit and 64-Bit Alarms
To configure an RMON alarm for one or more ports, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click the FC Interfaces > Create tab.
You see the create 32-bit and 64-bit alarm dialog box.
Step 2 Click the Select radio button to select individual ports for this threshold alarm.
a. Click the ... button to the right of the Selected field to display all ports.
b. Select the ports you want to monitor.
c. Click OK to accept the selection.
Alternatively, click the appropriate radio button to choose ports by type: All ports, xE ports, or Fx ports.
Step 3 Check the check box for each variable to be monitored.
Step 4 Enter the threshold value in the Value column.
Step 5 Enter the sampling period in seconds. This is the time between each snapshot of the variable.
Step 6 Choose one of the following severity levels to assign to the alarm: Fatal , Warning , Critical , Error , Information.
Step 8 Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event. If you do not confirm the operation, the system only defines a log event.
Step 9 Click More and then click the Alarms tab from the Threshold Manager dialog box to verify the alarm you created. The 32-bit and 64-bit alarm Interval columns show second as the unit.
Step 10 Close both dialog box pop-up windows.
Creating RMON Alarms
To create 64-bit RMON alarms, follow these steps:
Step 1 Expand Events and choose RMON from the Physical Attributes pane.
You see the 64-bit alarm dialog box.
Step 2 Click the 64-bit alarms tab.
Step 3 Click the Create Row tab. You see the Create Row window.
Step 4 From the drop-down menu in the Variable field, choose from the list of MIB variables provided by the Threshold Manager.
Note You need to supply the interface details along with variables selected from the drop-down list to complete the Variable field, for example, ifHCInOctets.
Step 5 Click the 32-bit alarms tab.
Step 6 Click the Create Row tab.
Step 7 From the drop-down menu in the Variable field, choose from the list of MIB variables provided by the Threshold Manager.
Step 8 Click the radio button to choose the RMON alarm to be created (32-bit or 64-bit HC Alarm).
Enabling 32-Bit RMON Alarms for VSANs
To enable an RMON alarm for one or more VSANs, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click the Services tab.
You see the Threshold Manager dialog box.
Step 2 Click the Services tab.
You see the Threshold Manager dialog box with the Services tab for 32-bit alarm selected.
Step 3 Click the 32-bit radio button.
Step 4 Enter one or more VSANs (multiple VSANs separated by commas) to monitor in the VSAN ID(s) field. Use the down arrow to see a list of available VSANs to choose from.
Step 5 Check the check box in the Select column for each variable to monitor.
Step 6 Enter the threshold value in the Value column.
Step 7 Enter the sampling period in seconds.
Step 8 Choose a severity level to assign to the alarm: Fatal , Critical , Error , Warning , Information .
Step 10 Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event.
If you do not confirm the operation, the system only defines a log event.
Step 11 Click More, and then click the Alarms tab in the Threshold Manager dialog box to verify the alarm you created.
Enabling 32-Bit and 64-Bit RMON Alarms for Physical Components
To configure an RMON alarm for a physical component for a 64-bit alarm, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click the Physical tab.
You see the Threshold Manager dialog box with the Physical tab for the 64-bit alarm selected.
Step 2 Check the check box in the Select column for each variable to monitor.
Step 3 Enter the threshold value in the Value column.
Step 4 Enter the sampling period in seconds.
Step 5 Choose one of the following severity levels to assign to the alarm: Fatal(1), Warning(2), Critical(3), Error(4), Information(5).
Step 7 Confirm the operation to define an alarm and a log event when the system prompts you to define a severity event.
If you do not confirm the operation, the system only defines a log event.
Step 8 Click More, and then click the 64-bit Alarms tab in the Threshold Manager dialog box to verify the alarm you created.
Note The MaxAlarm option is noneditable because of backend support. The max RMON alarms cannot be set using the CLI.
Restrictions
RMON does not check the RMON alarm configuration before configuring the switch.
To configure an RMON alarm from Device Manager Threshold Manager, follow these steps:
Step 1 Expand Events, choose RMON, and click the Control tab.
You see the create RMON alarm Threshold Manager dialog box.
A user error is prompted if adding the new alarm exceeds the maximum alarm.
Note This feature is applicable when managing switches Release 4.1(1b) and later. Device Manager can only treat the existing alarm number as 0 for the checking.
Managing RMON Events
To define customized RMON events, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click More in the Threshold Manager dialog box.
Step 2 Click the Events tab in the RMON Thresholds dialog box.
You see the RMON Thresholds Events tab.
Step 3 Click Create to create an event entry.
You see the Create RMON Thresholds Events dialog box.
Step 4 Configure the RMON threshold event attributes by choosing the type of event ( log , snmptrap , or logandtrap ).
Step 5 Increment the index. If you try to create an event with the existing index, you see a duplicate entry error message.
Step 6 (Optional) Provide a description and a community.
Step 7 Click Create, then close this dialog box.
Step 8 Verify that your event is listed in the remaining RMON Thresholds dialog box.
Step 9 Click Close to close the RMON Thresholds dialog box.
Managing RMON Alarms
To view the alarms that have already been enabled, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click More in the Threshold Manager dialog box.
You see the RMON Thresholds dialog box.
Step 3 Delete any alarm by selecting it, and then click Delete .
Viewing the RMON Log
To view the RMON log, follow these steps:
Step 1 Choose Admin > Events > Threshold Manager and click More on the Threshold Manager dialog box.
Step 2 Click the Log tab in the RMON Thresholds dialog box.
You see the RMON Thresholds Log tab. This is the log of RMON events that have been triggered by the Threshold Manager.
Verifying the RMON Configuration
To display the RMON configuration information, perform one of the following tasks:
For detailed information about the fields in the output from these commands, refer to the Cisco MDS 9000 Family Command Reference .
Use the show rmon and show snmp commands to display configured RMON and SNMP information (see Example 53-1 and 53-3 ).
Example 53-1 Displays Configured RMON Alarms
Example 53-2 Displays Configured RMON High Capacity Alarms
Note High capacity RMON alarms can be configured using the CISCO-HC-ALARM-MIB. See the Cisco MDS 9000 Family MIB Quick Reference.
Field Descriptions for RMON
This section describes the field descriptions for RMON.
RMON Thresholds Controls
RMON Thresholds 64bit Alarms
RMON Thresholds 32bit Alarms
RMON Thresholds Events
Additional References
For additional information related to implementing RMON, see the following section:
Feature History for RMON
Table 53-2 lists the release history for this feature. Only features that were introduced or modified in Release 3.x or a later release appear in the table.