Configuring Interfaces

This chapter describes the basic interface configuration to get your switch up and running.

This chapter includes the following topics:

Information About Interfaces

The main function of a switch is to relay frames from one data link to another. To relay the frames, the characteristics of the interfaces through which the frames are received and sent must be defined. The configured interfaces can be Fibre Channel interfaces, Gigabit Ethernet interfaces, the management interface (mgmt0), or VSAN interfaces.

This section includes the following topics:

Interface Description

For the Fibre Channel interfaces, you can configure the description parameter to provide a recognizable name for the interface. Using a unique name for each interface allows you to quickly identify the interface when you are looking at a listing of multiple interfaces. You can also use the description to identify the traffic or the use for that interface.

Interface Modes

Each physical Fibre Channel interface in a switch may operate in one of several port modes: E port, F port, FL port, TL port, TE port, SD port, ST port, and B port (see Figure 11-1). Besides these modes, each interface may be configured in auto or Fx port modes. These two modes determine the port type during interface initialization.

Figure 11-1 Cisco MDS 9000 Family Switch Port Modes

 


Note Interfaces are created in VSAN 1 by default. See the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide.


Each interface has an associated administrative configuration and an operational status:

  • The administrative configuration does not change unless you modify it. This configuration has various attributes that you can configure in administrative mode.
  • The operational status represents the current status of a specified attribute like the interface speed. This status cannot be changed and is read-only. Some values may not be valid when the interface is down (for example, the operational speed).

Note When a module is removed and replaced with the same type of module, the configuration is retained. If a different type of module is inserted, then the original configuration is no longer retained.


Each interface is briefly described in the sections that follow.

E Port

In expansion port (E port) mode, an interface functions as a fabric expansion port. This port may be connected to another E port to create an Inter-Switch Link (ISL) between two switches. E ports carry frames between switches for configuration and fabric management. They serve as a conduit between switches for frames destined to remote N ports and NL ports. E ports support class 2, class 3, and class F service.

An E port connected to another switch may also be configured to form a PortChannel (see Chapter 9, “Configuring PortChannels”).


Note We recommend that you configure E ports on 16-port modules. If you must configure an E port on a 32-port oversubscribed module, then you can only use the first port in a group of four ports (for example, ports 1 through 4, 5 through 8, and so forth). The other three ports cannot be used.


F Port

In fabric port (F port) mode, an interface functions as a fabric port. This port may be connected to a peripheral device (host or disk) operating as an N port. An F port can be attached to only one N port. F ports support class 2 and class 3 service.

FL Port

In fabric loop port (FL port) mode, an interface functions as a fabric loop port. This port may be connected to one or more NL ports (including FL ports in other switches) to form a public arbitrated loop. If more than one FL port is detected on the arbitrated loop during initialization, only one FL port becomes operational and the other FL ports enter nonparticipating mode. FL ports support class 2 and class 3 service.


Note FL port mode is not supported on 4-port 10-Gbps switching module interfaces.


NP Ports

An NP port is a port on a device that is in NPV mode and connected to the core switch via an F port. NP ports function like N ports except that in addition to providing N port operations, they also function as proxies for multiple, physical N ports.


Note A Cisco Nexus 5000 Series switch in NPV mode that runs Cisco NX-OS Release 4.2(1) or later releases supports trunking F port mode on NP ports. You can enable either, or both, VSAN trunking and an F port on an NP port.


For more details about NP ports and NPV, see Chapter10, “Configuring N Port Virtualization”

TL Port

In translative loop port (TL port) mode, an interface functions as a translative loop port. It may be connected to one or more private loop devices (NL ports). TL ports are specific to Cisco MDS 9000 Family switches and have similar properties as FL ports. TL ports enable communication between a private loop device and one of the following devices:

  • A device attached to any switch on the fabric
  • A device on a public loop anywhere in the fabric
  • A device on a different private loop anywhere in the fabric
  • A device on the same private loop

TL ports support class 2 and class 3 services.

Private loop devices refer to legacy devices that reside on arbitrated loops. These devices are not aware of a switch fabric because they only communicate with devices on the same physical loop (see the “TL Port ALPA Caches” section).


Tip We recommend configuring devices attached to TL ports in zones that have up to 64 zone members.



Note TL port mode is not supported on Generation 2 switching module interfaces.


TE Port

In trunking E port (TE port) mode, an interface functions as a trunking expansion port. It may be connected to another TE port to create an extended ISL (EISL) between two switches. TE ports are specific to Cisco MDS 9000 Family switches. They expand the functionality of E ports to support the following:

  • VSAN trunking
  • Transport quality of service (QoS) parameters
  • Fibre Channel trace (fctrace) feature

In TE port mode, all frames are transmitted in EISL frame format, which contains VSAN information. Interconnected switches use the VSAN ID to multiplex traffic from one or more VSANs across the same physical link. This feature is referred to as trunking in the Cisco MDS 9000 Family switches (see Chapter 8, “Configuring Trunking”). TE ports support class 2, class 3, and class F service.

TF Port

In trunking F port (TF port) mode, an interface functions as a trunking expansion port. It may be connected to another trunked N port (TN port) or trunked NP port (TNP port) to create a link between a core switch and an NPV switch or an HBA to carry tagged frames. TF ports are specific to Cisco MDS 9000 Family switches. They expand the functionality of F ports to support VSAN trunking.

In TF port mode, all frames are transmitted in EISL frame format, which contains VSAN information. Interconnected switches use the VSAN ID to multiplex traffic from one or more VSANs across the same physical link. This feature is referred to as trunking in the Cisco MDS 9000 Family (see Chapter 8, “Configuring Trunking”). TF ports support class 2, class 3, and class F service.

TNP Port

In trunking NP port (TNP port) mode, an interface functions as a trunking expansion port. It may be connected to a trunked F port (TF port) to create a link to a core NPIV switch from an NPV switch to carry tagged frames.

SD Port

In SPAN destination port (SD port) mode, an interface functions as a switched port analyzer (SPAN). The SPAN feature is specific to switches in the Cisco MDS 9000 Family. It monitors network traffic that passes though a Fibre Channel interface. This monitoring is done using a standard Fibre Channel analyzer (or a similar switch probe) that is attached to an SD port. SD ports do not receive frames, they only transmit a copy of the source traffic. The SPAN feature is nonintrusive and does not affect switching of network traffic for any SPAN source ports (see the Cisco MDS 9000 Family NX-OS System Management Configuration Guide ).

ST Port

In the SPAN tunnel port (ST port) mode, an interface functions as an entry point port in the source switch for the RSPAN Fibre Channel tunnel. The ST port mode and the remote SPAN (RSPAN) feature are specific to switches in the Cisco MDS 9000 Family. When configured in ST port mode, the interface cannot be attached to any device, and thus cannot be used for normal Fibre Channel traffic (see the Cisco MDS 9000 Family NX-OS System Management Configuration Guide ).


Note ST port mode is not supported on the Cisco MDS 9124 Fabric Switch, the Cisco Fabric Switch for HP c-Class BladeSystem, and the Cisco Fabric Switch for IBM BladeCenter.


Fx Port

Interfaces configured as Fx ports can operate in either F port or FL port mode. The Fx port mode is determined during interface initialization depending on the attached N port or NL port. This administrative configuration disallows interfaces to operate in any other mode—for example, preventing an interface to connect to another switch.

B Port

While E ports typically interconnect Fibre Channel switches, some SAN extender devices, such as the Cisco PA-FC-1G Fibre Channel port adapter, implement a bridge port (B port) model to connect geographically dispersed fabrics. This model uses B ports as described in the T11 Standard FC-BB-2.

If an FCIP peer is a SAN extender device that only supports Fibre Channel B ports, you need to enable the B port mode for the FCIP link. When a B port is enabled, the E port functionality is also enabled and they coexist. If the B port is disabled, the E port functionality remains enabled (see the Cisco MDS 9000 Family NX-OS IP Services Configuration Guide ).

Auto Mode

Interfaces configured in auto mode can operate in one of the following modes: F port, FL port, E port, TE port, or TF port. The port mode is determined during interface initialization. For example, if the interface is connected to a node (host or disk), it operates in F port or FL port mode depending on the N port or NL port mode. If the interface is attached to a third-party switch, it operates in E port mode. If the interface is attached to another switch in the Cisco MDS 9000 Family, it may become operational in TE port mode (see Chapter 8, “Configuring Trunking”).

TL ports and SD ports are not determined during initialization and are administratively configured.


Note Fibre Channel interfaces on Storage Services Modules (SSMs) cannot be configured in auto mode.


Interface States

The interface state depends on the administrative configuration of the interface and the dynamic state of the physical link.

Administrative States

The administrative state refers to the administrative configuration of the interface as described in Table 11-1 .

 

Table 11-1 Administrative States

Administrative State
Description

Up

Interface is enabled.

Down

Interface is disabled. If you administratively disable an interface by shutting down that interface, the physical link layer state change is ignored.

Operational States

The operational state indicates the current operational state of the interface as described in Table 11-2 .

 

Table 11-2 Operational States

Operational State
Description

Up

Interface is transmitting or receiving traffic as desired. To be in this state, an interface must be administratively up, the interface link layer state must be up, and the interface initialization must be completed.

Down

Interface cannot transmit or receive (data) traffic.

Trunking

Interface is operational in TE or TF mode.

Reason Codes

Reason codes are dependent on the operational state of the interface as described in Table 11-3 .

 

Table 11-3 Reason Codes for Interface States

Administrative Configuration
Operational Status
Reason Code

Up

Up

None.

Down

Down

Administratively down—If you administratively configure an interface as down, you disable the interface. No traffic is received or transmitted.

Up

Down

See Table 11-4 .


Note Only some of the reason codes are listed in Table 11-4.


If the administrative state is up and the operational state is down, the reason code differs based on the nonoperational reason code as described in Table 11-4 .

 

Table 11-4 Reason Codes for Nonoperational States

Reason Code (long version)
Description
Applicable Modes

Link failure or not connected

The physical layer link is not operational.

All

SFP not present

The small form-factor pluggable (SFP) hardware is not plugged in.

Initializing

The physical layer link is operational and the protocol initialization is in progress.

Reconfigure fabric in progress

The fabric is currently being reconfigured.

Offline

The Cisco NX-OS software waits for the specified R_A_TOV time before retrying initialization.

Inactive

The interface VSAN is deleted or is in a suspended state.

To make the interface operational, assign that port to a configured and active VSAN.

Hardware failure

A hardware failure is detected.

Error disabled

Error conditions require administrative attention. Interfaces may be error-disabled for various reasons. For example:

  • Configuration failure.
  • Incompatible buffer-to-buffer credit configuration.

To make the interface operational, you must first fix the error conditions causing this state; and next, administratively shut down or enable the interface.

FC redirect failure

A port is isolated because a Fibre Channel redirect is unable to program routes.

No port activation license available

A port is not active because it does not have a port license.

SDM failure

A port is isolated because SDM is unable to program routes.

Isolation due to ELP failure

The port negotiation failed.

Only E ports and TE ports

Isolation due to ESC failure

The port negotiation failed.

Isolation due to domain overlap

The Fibre Channel domains (fcdomain) overlap.

Isolation due to domain ID assignment failure

The assigned domain ID is not valid.

Isolation due to the other side of the link E port isolated

The E port at the other end of the link is isolated.

Isolation due to invalid fabric reconfiguration

The port is isolated due to fabric reconfiguration.

Isolation due to domain manager disabled

The fcdomain feature is disabled.

Isolation due to zone merge failure

The zone merge operation failed.

Isolation due to VSAN mismatch

The VSANs at both ends of an ISL are different.

Nonparticipating

FL ports cannot participate in loop operations. It may happen if more than one FL port exists in the same loop, in which case all but one FL port in that loop automatically enters nonparticipating mode.

Only FL ports and TL ports

PortChannel administratively down

The interfaces belonging to the PortChannel are down.

Only PortChannel interfaces

Suspended due to incompatible speed

The interfaces belonging to the PortChannel have incompatible speeds.

Suspended due to incompatible mode

The interfaces belonging to the PortChannel have incompatible modes.

Suspended due to incompatible remote switch WWN

An improper connection is detected. All interfaces in a PortChannel must be connected to the same pair of switches.

Graceful Shutdown

Interfaces on a port are shut down by default (unless you modified the initial configuration).

The Cisco NX-OS software implicitly performs a graceful shutdown in response to either of the following actions for interfaces operating in the E port mode:

  • If you shut down an interface.
  • If a Cisco NX-OS software application executes a port shutdown as part of its function.

A graceful shutdown ensures that no frames are lost when the interface is shutting down. When a shutdown is triggered either by you or the Cisco NX-OS software, the switches connected to the shutdown link coordinate with each other to ensure that all frames in the ports are safely sent through the link before shutting down. This enhancement reduces the chance of frame loss.

A graceful shutdown is not possible in the following situations:

  • If you physically remove the port from the switch.
  • If in-order delivery (IOD) is enabled (for information about IOD, refer to the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide ).
  • If the Min_LS_interval interval is higher than 10 seconds. For information about FSPF global configuration, refer to the Cisco MDS 9000 Family NX-OS Fabric Configuration Guide .

Note This feature is only triggered if both switches at either end of this E port interface are MDS switches and are running Cisco SAN-OS Release 2.0(1b) or later, or MDS NX-OS Release 4.1(1a) or later.


Port Administrative Speeds

By default, the port administrative speed for an interface is automatically calculated by the switch.

For internal ports on the Cisco Fabric Switch for HP c_Class BladeSystem and Cisco Fabric Switch for IBM BladeCenter, a port speed of 1 Gbps is not supported. Auto-negotiation is supported between 2 Gbps and 4 Gbps only. Also, if the BladeCenter is a T chassis, then port speeds are fixed at 2 Gbps and auto-negotiation is not enabled.

Autosensing

Autosensing speed is enabled on all 4-Gbps and 8-Gbps switching module interfaces by default. This configuration enables the interfaces to operate at speeds of 1 Gbps, 2 Gbps, or 4 Gbps on the 4-Gbps switching modules, and 8 Gbps on the 8-Gbps switching modules. When autosensing is enabled for an interface operating in dedicated rate mode, 4 Gbps of bandwidth is reserved, even if the port negotiates at an operating speed of 1 Gbps or 2 Gbps.

To avoid wasting unused bandwidth on 48-port and 24-port 4-Gbps and 8-Gbps Fibre Channel switching modules, you can specify that only 2 Gbps of required bandwidth be reserved, not the default of 4 Gbps or 8 Gbps. This feature shares the unused bandwidth within the port group provided that it does not exceed the rate limit configuration for the port. You can also use this feature for shared rate ports that are configured for autosensing.


Tip When migrating a host that supports up to 2-Gbps traffic (that is, not 4 Gbps with autosensing capabilities) to the 4-Gbps switching modules, use autosensing with a maximum bandwidth of 2 Gbps. When migrating a host that supports up to 4-Gbps traffic (that is, not 8 Gbps with autosensing capabilities) to the 8-Gbps switching modules, use autosensing with a maximum bandwidth of 4 Gbps.


Frame Encapsulation

The switchport encap eisl command only applies to SD port interfaces. This command determines the frame format for all frames transmitted by the interface in SD port mode. If the encapsulation is set to EISL, all outgoing frames are transmitted in the EISL frame format, regardless of the SPAN sources.

The switchport encap eisl command is disabled by default. If you enable encapsulation, all outgoing frames are encapsulated, and you will see a new line (Encapsulation is eisl) in the show interface SD_port_interface command output. See the Cisco MDS 9000 Family NX-OS System Management Configuration Guide .

You can set the frame format to EISL for all frames transmitted by the interface in SD port mode. If you sent the frame encapsulation to EISL, all outgoing frames are transmitted in the EISL frame format, regardless of the SPAN sources. See the Cisco MDS 9000 Family NX-OS System Management Configuration Guide .

Refer to the Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide to configure frame encapsulation on an interface.

Beacon LEDs

Figure 11-2 displays the status, link, and speed LEDs in a 16-port switching module.

Figure 11-2 Cisco MDS 9000 Family Switch Interface Modes

1

Status LED1

3

Link LEDs 1 and speed LEDs2

2

1/2-Gbps Fibre Channel port group3

4

Asset tag4

1.See the Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide.

4.Refer to the Cisco MDS 9000 Family hardware installation guide for your platform.

Speed LEDs

Each port has one link LED on the left and one speed LED on the right.

The speed LED displays the speed of the port interface:

  • Off—The interface attached to that port is functioning at 1000 Mbps.
  • On (solid green)—The interface attached to that port is functioning at 2000 Mbps (for 2 Gbps interfaces).

The speed LED also displays if the beacon mode is enabled or disabled:

  • Off or solid green—Beacon mode is disabled.
  • Flashing green—The beacon mode is enabled. The LED flashes at one-second intervals.

Note Generation 2, Generation 3, and Generation 4 modules and fabric switches do not have speed LEDs.


Bit Error Thresholds

The bit error rate threshold is used by the switch to detect an increased error rate before performance degradation seriously affects traffic.

The bit errors can occur for the following reasons:

  • Faulty or bad cable.
  • Faulty or bad GBIC or SFP.
  • GBIC or SFP is specified to operate at 1 Gbps but is used at 2 Gbps.
  • GBIC or SFP is specified to operate at 2 Gbps but is used at 4 Gbps.
  • Short haul cable is used for long haul or long haul cable is used for short haul.
  • Momentary sync loss.
  • Loose cable connection at one or both ends.
  • Improper GBIC or SFP connection at one or both ends.

A bit error rate threshold is detected when 15 error bursts occur in a 5-minute period. By default, the switch disables the interface when the threshold is reached. You can enter a shutdown and no shutdown command sequence to re-enable the interface.

You can configure the switch to not disable an interface when the threshold is crossed. By default, the threshold disables the interface.

SFP Transmitter Types

The small form-factor pluggable (SFP) hardware transmitters are identified by their acronyms when displayed. Table 11-5 defines the acronyms used for SFPs.

The small form-factor pluggable (SFP) hardware transmitters are identified by their acronyms when displayed in the show interface brief command. If the related SFP has a Cisco-assigned extended ID, then the show interface and show interface brief commands display the ID instead of the transmitter type. The show interface transceiver command and the show interface fc slot / port transceiver command display both values for Cisco-supported SFPs. Table 11-5 defines the acronyms used in the command output (see the “Displaying Interface Information” section).

 

Table 11-5 SFP Transmitter Acronym Definitions

Definition
Acronym
Standard transmitters defined in the GBIC specifications

short wave laser

swl

long wave laser

lwl

long wave laser cost reduced

lwcr

electrical

elec

Extended transmitters assigned to Cisco-supported SFPs

CWDM-1470

c1470

CWDM-1490

c1490

CWDM-1510

c1510

CWDM-1530

c1530

CWDM-1550

c1550

CWDM-1570

c1570

CWDM-1590

c1590

CWDM-1610

c1610

See the “Displaying SFP Transmitter Types” section.

TL Ports

Private loop devices refer to legacy devices that reside on arbitrated loops. These devices are not aware of a switch fabric because they only communicate with devices on the same physical loop. The legacy devices are used in Fibre Channel networks, and devices outside the loop may need to communicate with them. The communication functionality is provided through TL ports. See the “Interface Modes” section.

TL port mode is not supported on the following hardware:

  • Generation 2 switching module interfaces
  • Cisco MDS 9124 Fabric Switch
  • Cisco Fabric Switch for HP c-Class BladeSystem
  • Cisco Fabric Switch for IBM BladeCenter

Table 11-6 lists the TL port translations supported in Cisco MDS 9000 Family switches.

 

Table 11-6 Supported TL Port Translations

Translation from
Translation to
Example

Private initiator

Private target

From I1 to T1 or vice versa

Private initiator

Public target — N port

From I1 to T2 or vice versa

Private initiator

Public target — NL port

From I4 to T3 or vice versa

Public initiator — N port

Private target

From I2 to T1 or vice versa

Public initiator — NL port

Private target

From I3 to T1 or vice versa

Figure 11-3 shows examples of TL port translation support.

Figure 11-3 TL Port Translation Support Examples

 

TL Port ALPA Caches

Although TL ports cannot be automatically configured, you can manually configure entries in arbitrated loop physical address (ALPA) caches. Generally, ALPA cache entries are automatically populated when an ALPA is assigned to a device. Each device is identified by its port world wide name (pWWN). When a device is allocated an ALPA, an entry for that device is automatically created in the ALPA cache.

A cache contains entries for recently allocated ALPA values. These caches are maintained on various TL ports. If a device already has an ALPA, the Cisco NX-OS software attempts to allocate the same ALPA to the device each time. The ALPA cache is maintained in persistent storage and saves information across switch reboots. The maximum cache size is 1000 entries. If the cache is full, and a new ALPA is allocated, the Cisco NX-OS software discards an inactive cache entry (if available) to make space for the new entry. See the “TL Port” section for more information on TL ports.

Refer to the Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide to manage the TL Port ALPA cache.

Port Guard

The port guard feature is intended for use in environments where the system and application environment does not adapt quickly and efficiently to a port going down and back up, or to a port rapidly cycling up and down, which can happen in some failure modes. For example, if a system takes five seconds to stabilize after a port goes down, but the port is going up and down once a second, a more severe failure in the fabric might occur.

The port guard feature gives the SAN administrator the ability to prevent this issue from occurring in environments that are vulnerable to these problems. The port can be configured to stay down after the first failure or after a specified number of failures in a specified time period. This allows the SAN administrator to intervene and control the recovery, avoiding any problems caused by the cycling.

Using the port guard feature, you can restrict the number of error reports and bring a malfunctioning port to down state dynamically. A port can be configured to go into error-disabled state for specific types of failures.

A general link failure caused by link-down is the superset of all other causes. The sum of the number of all other causes equals to the number of link-down link failures. This means a port is brought to down state when it reaches the maximum number of allowed link failures or the number of specific causes.

The causes of link failure can be any of the following:

  • ESP trustsec-violation
  • Bit-errors
  • Signal loss
  • Sync loss
  • Link reset
  • Credit loss
  • Additional causes might be the following:

– Not operational (NOS).

– Too many interrupts.

– Cable is disconnected.

– Hardware recoverable errors.

– The connected device rebooted (F ports only).

– The connected linecard rebooted (ISL only).

Port Monitor

Port monitor helps to monitor the performance and the status of ports and generate alerts when problems occur. You can configure the thresholds for various counters and trigger an event when the values cross the threshold settings.

The default port monitor policy has the following threshold values:

 

Counter
Threshold Type
Interval (Seconds)
% Rising Threshold
Event
% Falling Threshold
Event

Link Loss

Delta

60

5

4

1

4

Sync Loss

Delta

60

5

4

1

4

Protocol Error

Delta

60

1

4

0

4

Signal Loss

Delta

60

5

4

1

4

Invalid Words

Delta

60

1

4

0

4

Invalid CRCs

Delta

60

5

4

1

4

RX Performance

Delta

60

2147483648

4

524288000

4

TX Performance

Delta

60

2147483648

4

524288000

4

Port Monitor Port Guard

Port monitor port guard is a feature that disables or shuts down a port when an event occurs. Depending on the configuration, when an event occurs the port is either error-disabled or flapped.

Port monitor port guard is a different or separate feature that functions based on the configuration of the errordisable command.

Port Group Monitor

Each line card or module has a predefined set of ports which share the same backplane bandwidth called port groups. While oversubscription is a feature, the port group monitor feature helps to monitor the spine bandwidth utilization. An alarm syslog is generated so that you can provision the ports across port groups evenly to manage the oversubscription better.

When the port group monitor feature is enabled and a policy consisting of polling interval in seconds, and the raising and falling thresholds in percentage are specified, port group monitor generates a syslog if a port group traffic goes above the specified percentage of the maximum supported bandwidth for that port group (for rx and for tx) and another syslog if the value falls below the specified threshold.

The default port group policy has the following threshold values:

 

Counter
Threshold Type
Interval (Seconds)
% Rising Threshold
% Falling Threshold

RX Performance

Delta

60

80

20

TX Performance

Delta

60

80

20

Local Switching

Local switching can be enabled in Generation 4 modules, which allows traffic to be switched directly with a local crossbar when the traffic is directed from one port to another on the same line card. By using local switching, an extra switching step is avoided, which decreases the latency.

When using local switching, note the following guidelines:

  • All ports need to be in shared mode, which usually is the default state. To place a port in shared mode, enter the switchport ratemode shared command.
  • E ports are not allowed in the module because they must be in dedicated mode.

Slow Drain Device Detection and Congestion Avoidance

All data traffic between end devices in a SAN fabric is carried by Fibre Channel Class 3. In some cases, the traffic is carried by Class 2 services that use link-level, per-hop-based, and buffer-to-buffer flow control. These classes of service do not support end-to-end flow control. When there are slow devices attached to the fabric, the end devices do not accept the frames at the configured or negotiated rate. The slow devices lead to ISL credit shortage in the traffic destined for these devices and they congest the links. The credit shortage affects the unrelated flows in the fabric that use the same ISL link even though destination devices do not experience slow drain.

This feature provides various enhancements to detect slow drain devices that are causing congestion in the network and also provides a congestion avoidance function.

This feature is focused mainly on the edge ports that are connected to slow drain devices. The goal is to avoid or minimize the frames being stuck in the edge ports due to slow drain devices that are causing ISL blockage. To avoid or minimize the stuck condition, configure lesser frame timeout for the ports. No-credit timeout drops all packets once the slow drain is detected using the configured thresholds. The lesser frame timeout value helps to alleviate the slow drain condition that affects the fabric by dropping the packets on the edge ports sooner than the time they actually get timed out (500 ms). This function frees the buffer space in ISL, which can be used by other unrelated flows that do not experience slow drain condition.


Note This feature is used mainly for edge ports that are connected to slow edge devices. Even though this feature can be applied to ISLs as well, we recommend that you apply this feature only for edge F ports and retain the default configuration for ISLs as E and TE ports. This feature is not supported on Generation 1 modules.


Management Interfaces

You can remotely configure the switch through the management interface (mgmt0). To configure a connection on the mgmt0 interface, you must configure either the IP version 4 (IPv4) parameters (IP address, subnet mask, and default gateway) or the IP version 6 (IPv6) parameters so that the switch is reachable.

Before you begin to configure the management interface manually, obtain the switch’s IPv4 address and subnet mask, or the IPv6 address.

The management port (mgmt0) is autosensing and operates in full-duplex mode at a speed of 10/100/1000 Mbps. Autosensing supports both the speed and the duplex mode. On a Supervisor-1 module, the default speed is 100 Mbps and the default duplex mode is auto. On a Supervisor-2 module, the default speed is auto and the default duplex mode is auto.


Note You need to explicitly configure a default gateway to connect to the switch and send IP packets or add a route for each subnet.


VSAN Interfaces

VSANs apply to Fibre Channel fabrics and enable you to configure multiple isolated SAN topologies within the same physical infrastructure. You can create an IP interface on top of a VSAN and then use this interface to send frames to this VSAN. To use this feature, you must configure the IP address for this VSAN. VSAN interfaces cannot be created for nonexisting VSANs.

Prerequisites for Interfaces

Before you begin configuring the interfaces, ensure that the modules in the chassis are functioning as designed. To verify the status of a module at any time, enter the show module command in EXEC mode. For information about verifying the module status, refer to the Cisco NX-OS Fundamentals Configuration Guide .

Guidelines and Limitations

This section includes the following topics:

Generation 1 Interface Configuration Guidelines

The Generation 1 interfaces configuration guidelines apply to the following hardware:

  • The 32-port, 2-Gbps or 1-Gbps switching module interfaces
  • The Cisco MDS 9140 and 9120 switch interfaces

Note Due to the hardware design of the MDS 9134 switch, we do not support interface out-of-service action on either of its two 10-Gigabit ports. This is because no internal port hardware resource is released when an out-of-service action is performed on these 10-Gigabit ports.


When configuring these host-optimized ports, the following port mode guidelines apply:

  • You can configure only the first port in each 4-port group (for example, the first port in ports 1-4, the fifth port in ports 5-8, and so on) as an E port. If the first port in the group is configured as an E port, the other three ports in each group (ports 2-4, 6-8, and so on) are not usable and remain shutdown.
  • If you execute the write erase command on a 32-port switching module, and then copy a saved configuration to the switch from a text file that contains the no system default switchport shutdown command, you need to copy the text file to the switch again for the E ports to come up without manual configuration.
  • If any of the other three ports are enabled, you cannot configure the first port as an E port. The other three ports continue to remain enabled.
  • The auto mode is not allowed in a 32-port switching module or the host-optimized ports in the Cisco 9100 Series (16 host-optimized ports in the Cisco MDS 9120 switch and 32 host-optimized ports in the Cisco MDS 9140 switch).
  • The default port mode is Fx (Fx negotiates to F or FL) for 32-port switching modules.
  • The 32-port switching module does not support FICON.

Note We recommend that you configure your E ports on a 16-port switching module. If you must configure an E port on a 32-port host-optimized switching module, the other three ports in that 4-port group cannot be used.



Note In the Cisco MDS 9100 Series, the groups of ports that are located on the left and outlined in white are full line rate. The other ports are host-optimized. Each group of 4 host-optimized ports have the same features as for the 32-port switching module.


Private Loop Configuration Guidelines

Follow these guidelines when configuring private loops:

  • A maximum of 64 fabric devices can be proxy to a private loop.
  • Fabric devices must be in the same zone as private loop devices to be proxy to the private loop.
  • Each private device on a TL port may be included in a different zone.
  • All devices on the loop are treated as private loops. You cannot mix private and public devices on the loop if the configured port mode is TL.
  • The only FC4-type supported by TL ports is SCSI (FCP).
  • Communication between a private initiator to a private target on the same private loop does not invoke TL port services.

VSAN Interface Configuration Guidelines

Follow these guidelines when creating or deleting VSAN interfaces:

  • Create a VSAN before creating the interface for that VSAN. If a VSAN does not exist, the interface cannot be created.
  • Create the interface VSAN—it is not created automatically.
  • If you delete the VSAN, the attached interface is automatically deleted.
  • Configure each interface only in one VSAN.

Tip After configuring the VSAN interface, you can configure an IP address or Virtual Router Redundancy Protocol (VRRP) feature. See the Cisco MDS 9000 Family NX-OS IP Services Configuration Guide.


Default Settings

 

Table 11-7 lists the default settings for interface parameters.

 

Table 11-7 Default Interface Parameters

Parameters
Default

Interface mode

Auto

Interface speed

Auto

Administrative state

Shutdown (unless changed during initial setup)

Trunk mode

On (unless changed during initial setup) on non-NPV and NPIV core switches. Off on NPV switches.

Trunk-allowed VSANs or VF-IDs

1 to 4093

Interface VSAN

Default VSAN (1)

Beacon mode

Off (disabled)

EISL encapsulation

Disabled

Data field size

2112 bytes

Configuring Interfaces

This section includes the following topics:

For more information on configuring mgmt0 interfaces, refer to the Cisco MDS 9000 Family NX-OS Fundamentals Configuration Guide and Cisco MDS 9000 Family NX-OS IP Services Configuration Guide .

For more information on configuring Gigabit Ethernet interfaces, see the Cisco MDS 9000 Family NX-OS IP Services Configuration Guide .

Common Interface Configuration

Some configuration settings are similar for Fibre Channel, management, and VSAN interfaces. You can configure interfaces from DCNM-SAN by expanding Switches > FC Interfaces and selecting either the Physical or Logical interface type from the Physical Attributes pane.

Configuring Fibre Channel Interfaces

To configure a Fibre Channel interface, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

switch(config-if)#

Selects a Fibre Channel interface and enters interface configuration submode.

Note When a Fibre Channel interface is configured, it is automatically assigned a unique world wide name (WWN). If the interface’s operational state is up, it is also assigned a Fibre Channel ID (FC ID).

To configure a range of interfaces, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1 - 4 , fc2/1 - 3

switch(config-if)#

Selects the range of Fibre Channel interfaces and enters interface configuration submode3.

Note In this command, provide a space before and after the comma.

For the Cisco Fabric Switch for HP c-Class BladeSystem and the Cisco Fabric Switch for IBM BladeCenter, you can configure a range of interfaces among internal ports or external ports, but you cannot mix both interface types within the same range. For example, “bay 1-10, bay 12” or “ext 0, ext 15-18” are valid ranges, but “bay 1-5, ext 15-17” is not.

Setting the Interface Administrative State

To gracefully shut down an interface, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

Selects a Fibre Channel interface and enters interface configuration submode.

Step 3

switch(config-if)# shutdown

Gracefully shuts down the interface and administratively disables traffic flow (default).

To enable traffic flow, follow these steps

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

Selects a Fibre Channel interface and enters interface configuration submode.

Step 3

switch(config-if)# no shutdown

Enables traffic flow to administratively allow traffic when the no prefix is used (provided the operational state is up).

 

To disable or enable an interface using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical. You see the interface configuration in the Information pane.

Step 2 Click the General tab.

Step 3 Click Mode admin.

You see the drop-down box.

Step 4 Set the status or mode to the required status.

Step 5 (Optional) Set other configuration parameters using the other tabs.

Step 6 Click Apply Changes.


 

Configuring Interface Modes

To configure the interface mode, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

switch(config-if)#

Selects a Fibre Channel interface and enters interface configuration submode.

Step 3

switch(config-if)# switchport mode F

switch(config-if)#

Configures the administrative mode of the port. You can set the operational state to auto, E, F, FL, Fx, TL, NP, or SD port mode.

Note Fx ports refers to an F port or an FL port (host connection only), but not E ports.

switch(config-if)# switchport mode auto

switch(config-if)#

Configures the interface mode to auto-negotiate an E, F, FL, or TE port mode (not TL or SD port modes) of operation.

Note TL ports and SD ports cannot be configured automatically. They must be administratively configured.

Note You cannot configure Fibre Channel interfaces on SSMs in auto mode.

 

To configure the interface mode using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical.

You see the interface configuration in the Information pane.

Step 2 Click the General tab.

Step 3 Click Mode Admin. Set the desired interface mode from the Admin drop-down menu.

Step 4 (Optional) Set other configuration parameters using the other tabs.

Step 5 Click Apply Changes icon.


 

Configuring 10-Gbps FC Mode

The 48-port 8-Gbps Advanced Fibre Channel module (DS-X9248-256K9) and the 32-port 8-Gbps Advanced Fibre Channel module (DS-X9232-256K9)can switch between two speed modes—the 1-, 2-, 4-, 8-Gbps or 10-Gbps. By default, the modules are online in the 1-, 2-, 4-, and 8-Gbps modes when they are loaded for the first time. There are two ways to change the ports to the 10-Gbps speed mode:

  • Using the 10G-speed mode command, which is the recommended method.
  • Using the generic speed configuration switchport speed command which has certain constraints.

The following conditions apply when the ports in the module can be configured to 10-Gbps speed mode:

  • The ports in the module can be configured to 10-Gbps speed only when the DS-13SLT-FAB3 module bandwidth is 256-G. Any other combination of fabric modules will not let the ports come up in 10-Gbps.
  • When in 10-Gbps mode, the ports in the module that are not 10-Gbps capable are disabled and will be in out-of-service state.
  • The ports function only in full rate mode. They cannot be moved to shared rate mode.
  • The ports cannot be configured in any other speed.
  • Ports that are capable of 10-Gbps that are disabled or out-of-service cannot be put back in service using the no out-of-service command. To put these ports back in service, all ports in the module first have to be moved to the out-of-service state. Then they can be brought back to the in service state.
  • Local switching must be disabled, otherwise, ports cannot be configured in dedicated mode.

Only certain ports on the 48-port and 32-port 8-Gbps Advanced Fibre Channel modules are 10-Gbps capable. When running in 10-Gbps mode, the non-10-Gbps ports cannot be operational. They have to be either in shut state or out-of-service state.

 

To configure the interface mode, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1-12

switch(config-if)#

Selects a Fibre Channel interface and enters interface configuration submode.

Note Ensure that one full ASIC range of ports are selected before executing this command. For example, /1-12 for a 48-port module or fcY/1-8 for a 32-port module.

The first ASIC on the 48-port module has ports fc1/1-12.

Step 3

switch(config-if)# 10G-speed-mode

Configures all the ports (fc1 to 12) to out-of-service state.

Moves the ports that are capable of a10-Gbps configuration (fc1/4-8 and fc1/10) to in-service state.

Sets the speed on ports fc1/4-8 and fc1/10 to 10-Gbps.

Sets port modes on these ports to dedicated.

Performs a no shut on these ports.

switch(config-if)# no 10G-speed-mode

Reverts the settings and puts all the ports (fc1 to 12) in out-of-service state and moves them to in-service state.

To configure the interface mode using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical.

You see the interface configuration in the Information pane.

Step 2 Click the General tab.

Step 3 Click Mode Admin. Set the desired interface mode from the Admin drop-down menu.

Step 4 (Optional) Set other configuration parameters using the other tabs.

Step 5 Click Apply Changes icon.


 

Configuring Port Administrative Speeds

Restrictions

  • Changing the port administrative speed is a disruptive operation.

 

To configure the port speed of the interface, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc 1/1

Selects the mgmt0 interface and enters interface configuration mode.

Step 3

switch(config-if)# switchport speed 1000

Configures the port speed of the interface to 1000 Mbps.

The number indicates the speed in megabits per second (Mbps). You can set the speed to 1000 (for 1-Gbps interfaces), 2000 (for 2-Gbps interfaces), 4000 (for 4-Gbps interfaces), 8000 (for 8-Gbps interfaces), or auto (default).

switch(config-if)# switchport speed 10000

Configures the port speed of the interface to 10000 Mbps (for 10-Gbps).

Note All the 10-Gbps capable interfaces, except the interface that is being configured, must be in the out-of-service state. At least one other 10-Gbps capable interface must be in the in-service state.

switch(config-if)# no switchport speed

Reverts the factory default (auto) administrative speed of the interface.

 

To configure the administrative speed of the interface using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical.

You see the interface configuration in the Information pane.

Step 2 Click the General tab.

Step 3 Click Speed Admin. Set the desired speed from the drop-down menu.

The number indicates the speed in megabits per second (Mbps). You can set the speed to 1-Gbps, 2-Gbps, 4-Gbps, 8-Gbps, autoMax2G, autoMax4G, or auto (default).


Note On a Cisco Nexus 5000 Series switch that runs Cisco NX-OS Release 4.2(2), you can configure the 8-Gbps administrative speed only on a M1060 switch module. You can configure the speed to 1-Gbps, 2-Gbps, or 4-Gbps on all switch modules on a Cisco Nexus 5000 Series switch that runs Cisco NX-OS Release 4.2(2) or earlier releases.


Step 4 Click Apply Changes.


 

Configuring Port Speed Group

To configure the port speed group of the interface, follow these steps:

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc 1/1

Selects the mgmt0 interface and enters interface configuration mode.

Step 3

switch(config-if)# speed group 10000

Configures the port speed group to 10 Gbps.

The number indicates the speed in Gbps (Gbps). You can set the speed to 1000 (for 1-Gbps interfaces), 2000 (for 2-Gbps interfaces), 4000 (for 4-Gbps interfaces), 8000 (for 8-Gbps interfaces), 10000 (for 10-Gbps interfaces), or auto (default).

switch(config-if)# no speed group speed

Unsets the port speed group and reverts to the factory default (auto) administrative speed group of the interface.

 

To configure the administrative speed of the interface using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical.

You see the interface configuration in the Information pane.

Step 2 Click the General tab.

Step 3 Click SpeedGroup. Set the desired speed group from the drop-down menu.

You can select any of the speed groups from the menu list—notApplicable, tenG, oneTwoFourEightG, or twoFourEightSixteenG.


Note For a DS-X9248-256K9 or DS-X9232-256K9 line card, the speed group must be set to tenG.


Step 4 Click Apply Changes.


 

Configuring the Interface Description

The interface description can be any alphanumeric string.

To configure a description for an interface, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

switch(config-if)#

Selects a Fibre Channel interface and enters interface configuration submode.

Step 3

switch(config-if)# switchport description cisco-HBA2

Configures the description of the interface. The string can be up to 80 characters long.

switch(config-if)# no switchport description

Clears the description of the interface.

Specifying a Port Owner

Using the port owner feature, you can specify the owner of a port and the purpose for which a port is used so that the other administrators are informed.


Note The port guard and port owner features are available for all ports regardless of the operational mode.


To specify or remove the port owner, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

Selects the port interface.

Step 3

switch(config)# switchport owner description

Specifies the owner of the switch port. The description can include name of the owner and the purpose for which the port is used. The description can be up to 80 characters long.

switch(config)# no switchport owner

Removes (default) the port owner description.

To display the owner description specified for a port, use the following commands:

switch# show running interface fc module-number/interface-number
switch# show port internal info interface fc module-number/interface-number
 

To specify or remove the port owner using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical.

You see the interface configuration in the Information pane.

Step 2 Click the General tab and then select the switch/port.

Step 3 In the Owner text box, enter a port owner and the purpose for which port is used.


 

To specify or remove the port owner using Device Manager, follow these steps:


Step 1 Double-click the interface in the modules panel.

Step 2 Click the General tab.

Step 3 In the Owner text box, enter a port owner and the purpose for which the port is used.

Step 4 Click Apply .


 

Configuring Beacon Mode

By default, the beacon mode is disabled on all switches. The beacon mode is indicated by a flashing green light that helps you identify the physical location of the specified interface. Configuring the beacon mode has no effect on the operation of the interface.

 

To enable beacon mode for a specified interface or range of interfaces, follow these steps:

 
Command
Purpose

Step 1

switch# config t

switch(config)#

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

switch(config-if)#

Selects a Fibre Channel interface and enters interface configuration submode.

Step 3

switch(config-if)# switchport beacon

Enables the beacon mode for the interface.

switch(config-if)# no switchport beacon

Disables the beacon mode for the interface.

To enable beacon mode for a specified interface or range of interfaces using DCNM-SAN, follow these steps:


Step 1 Expand Switches > Ethernet Interfaces > Physical > IPS (the Gigabit Ethernet Interfaces).

You see the interface configuration in the Information pane.

Step 2 Click the Beacon Mode and enable this option for the selected switch.

Step 3 Click Apply Changes .


 

Troubleshooting Tips

  • The flashing green light turns on automatically when an external loopback is detected that causes the interfaces to be isolated. The flashing green light overrides the beacon mode configuration. The state of the LED is restored to reflect the beacon mode configuration after the external loopback is removed.

Disabling Bit Error Threshold

To disable the bit error threshold for an interface, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

switch(config-if)#

Selects a Fibre Channel interface and enters interface configuration submode.

Step 3

switch(config-if)# switchport ignore bit-errors

Prevents the detection of bit error threshold events from disabling the interface.

switch(config-if)# no switchport ignore bit-errors

Prevents the detection of bit error threshold events from enabling the interface.

Troubleshooting Tips

  • Regardless of the setting of the switchport ignore bit-errors command, the switch generates a syslog message when bit-error threshold events are detected.

Note Even if you disable the switch port ignore bit-error threshold for an interface, the switch generates a syslog message when bit-error threshold events are detected.


Configuring Switch Port Attribute Default Values

You can configure attribute default values for various switch port attributes. These attributes will be applied globally to all future switch port configurations, even if you do not individually specify them at that time.

To configure switch port attributes, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# no system default switchport shutdown

switch(config)#

Configures the default setting for administrative state of an interface as Up. (The factory default setting is Down).

Tip This command is applicable only to interfaces for which no user configuration exists for the administrative state.

switch(config)# system default switchport shutdown

switch(config)#

Configures the default setting for administrative state of an interface as Down. This is the factory default setting.

Tip This command is applicable only to interfaces for which no user configuration exists for the administrative state.

switch(config)# system default switchport trunk mode auto

switch(config)#

Configures the default setting for administrative trunk mode state of an interface as Auto.

Note The default setting is trunk mode on.

Configuring TL Ports

Private loops require setting the interface mode to TL.

Use the switchport mode command to configure a TL port. See the “Configuring Interface Modes” section.

To configure the TL interface mode using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical. You see the interface configuration in the Information pane.

Step 2 Click the General tab and click Mode Admin.

Step 3 Set the Mode Admin drop-down menu to the required status.

Step 4 (Optional) Set other configuration parameters using the other tabs.

Step 5 Click Apply Changes.


 

Manually Inserting Entries into the ALPA Cache

To manually insert entries into the ALPA cache, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# tlport alpa-cache interface fc1/2 pwwn 22:00:00:20:37:46:09:bd alpa 0x02

Configures manual entries into the ALPA cache.

Step 3

switch(config)# tlport alpa-cache interface fc1/3 pwwn 22:00:00:20:37:46:09:bd

Removes this entry from the ALPA cache.

Clearing the ALPA Cache

The clear tlport alpa-cache command clears the entire content of the ALPA cache.

Configuring Port Guard

To enable or disable the port guard for a port, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# interface fc1/1

Selects the port interface.

Step 3

switch(config)# errdisable detect cause link-down

Brings the port to down state if the link flaps once.

switch(config)# errdisable detect cause link-down [ num-times number duration seconds ]

Enables the port guard configuration for the interface. Brings the port to down state if the link flaps for the number of instances within the specified seconds .

switch(config)# no errdisable detect cause link-down

Removes (default) the port guard configuration for the interface. The link resumes flapping and sending error reports normally.

Step 4

switch(config)# errdisable detect cause { trustsec-violation | bit-errors | credit-loss | link-reset | signal-loss | sync-loss }

Brings the port to down state if the specified error occurs even once.

switch(config)# errdisable detect cause { trustsec-violation | bit-errors | credit-loss | link-reset | signal-loss | sync-loss } [ num-times number duration seconds ]

Brings the port to down state if the specified error occurs for the number of instances within the specified seconds .

switch(config)# no errdisable detect cause { trustsec-violation | bit-errors | credit-loss | link-reset | signal-loss | sync-loss }

Removes (default) the port guard configuration for the interface. The link resumes flapping and sending error reports normally.

 

To enable port guard using DCNM-SAN, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical > Port Guard from the Physical Attributes pane.

You see the interfaces listed in the Information pane.

Step 2 Click the Link Down tab and then select a switch or port.

Step 3 Check the check box in the Enable column.

Step 4 (Optional) Enter the Duration in seconds and the number of flaps. If the values are 0, the port is brought to down state if the link flaps even once. Otherwise, the link is brought to down state if the link flaps for the number of flaps within the duration.

Step 5 Click Apply Changes to activate the configuration.

Step 6 Click the TrustSec Violation tab, and then select a switch or port.

Step 7 Check the check box in the Enable column.

Step 8 (Optional) Enter the duration in seconds and the number of flaps. If the values are 0, the port is brought to down state if a trustsec violation occurs even once. Otherwise, the link is brought to down state if there is trustsec violation for the number of flaps within the duration.

Step 9 Click the Bit Errors , Signal Loss , Sync Loss , Link-reset , and Credit Loss tabs and complete the port guard configuration.

Step 10 Click Apply Changes to activate the configuration.


 

 

To enable port guard for single or multiple interfaces using Device Manager, follow these steps:


Step 1 Expand Switches > FC Interfaces > Physical > Port Guard from the Physical Attributes pane.

You see the FC Interfaces listed.

Step 2 Click the Link Down tab, and then select the switch or port.

Step 3 Check the check box in the Enable column.

Step 4 (Optional) Enter the duration in seconds and the number of flaps. If the values are 0, the port goes into a down state even if the link flaps once. Otherwise, the link goes into a down state if the link flaps for the number of flaps within the duration.

Step 5 Click Apply Changes to activate the configuration.

Step 6 Click the TrustSec Violation tab, and then select the switch or port.

Step 7 Check the check box in the Enable column.

Step 8 (Optional) Enter the Duration in seconds and the number of flaps. If the values are 0, the port is brought to down state if a trustsec violation occurs even once. Otherwise, the link is brought to down state if a trustsec violation occurs for the number of flaps within the duration.

Step 9 Click Apply Changes to activate the configuration.


 

Examples

This example shows how to configure port guard to bring a port to down state if the link flaps 5 times within 120 seconds based on multiple causes:

Switch# config t
Switch (config)# interface fc1/1
Switch (config-if)# errdisable detect cause link-down num-times 5 duration 120
Switch (config-if)# errdisable detect cause bit-errors num-times 5 duration 120
Switch (config-if)# errdisable detect cause credit-loss num-times 5 duration 120
 

The above example sets the configuration to the following status:

  • The port will be error-disabled due to bit errors if the port suffers link failure due to bit errors 5 times in 120 seconds.
  • The port will be error-disabled due to credit loss if the port suffers link failure due to credit loss 5 times in 120 seconds.
  • The port will be error-disabled due to link down if the port suffers link failure due to bit errors 2 times and link-failure due to credit loss 3 times in 120 seconds.

This example shows the internal information about a port in down state because of TrustSec violation:

Switch# show port internal info interface fc8/3
fc8/3 is down (Error disabled - port down due to trustsec violation)
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 21:c3:00:0d:ec:10:57:80
Admin port mode is E, trunk mode is on
snmp link state traps are enabled
Port vsan is 1
Receive data field Size is 2112
Beacon is turned off
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
11274 frames input, 1050732 bytes
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
11242 frames output, 971900 bytes
0 discards, 0 errors
11 input OLS, 34 LRR, 10 NOS, 0 loop inits
72 output OLS, 37 LRR, 2 NOS, 0 loop inits
Interface last changed at Sun Nov 27 07:34:05 1988
 
admin port-down trustsec-violation(3) num_times 0, duration = 0
state reason (Error disabled - port down due to trustsec violation)
Port guard trustsec violation is Enabled
errdisabled on trustsec violation TRUE, oper cnt = 1
port guard first trustsec violation Sun Nov 27 07:34:05 1988
 

Troubleshooting Tips

  • Link down is the superset of all other causes. A port is brought to down state if the total number of other causes equals to the number of allowed link-down failures.
  • Even if the link does not flap due to failure of the link, and port guard is not enabled, the port goes into a down state if too many invalid FLOGI requests are received from the same host. Use the shut and the no shut commands consecutively to bring up the link.

Configuring Port Monitor

This section includes the following topics:

Enabling Port Monitor

To enable port monitor, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# port-monitor enable

Enables (default) port monitoring.

switch(config)# no port-monitor enable

Disables port monitoring.

Configuring a Port Monitor Policy

To configure a port monitor policy, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# port-monitor name policyname

Specifies the policy name and enters the port monitoring policy configuration mode.

switch(config)# no port-monitor name policyname

Removes the policy.

switch# config t

Enters configuration mode.

Step 3

switch(config-port-monitor)# port-type access-port

Applies the policy to the access ports.

switch(config-port-monitor)# port-type trunks

Applies the policy to the trunk ports.

switch(config-port-monitor)# port-type all

Applies the policy to all ports.

Step 4

switch(config-port-monitor)# counter credit-loss-reco poll-interval seconds percentage1 event event-id delta rising-threshold percentage1 event event-id

Specifies the delta credit loss recovery counter, poll interval in seconds, the thresholds in percentage, and the event IDs of events.

Step 5

switch(config-port-monitor)# monitor counter err-pkt-from-port5

 

switch(config-port-monitor)# counter err-pkt-from-port 1 poll-interval seconds delta rising-threshold eventcount1 event event-id falling-threshold6 eventcount2 event event-id

Activates the err-pkt-from-port counter.

Specifies the delta err-pkt-from-port counter, poll interval in seconds, the thresholds in percentage, and the event IDs of events.

Step 6

switch(config-port-monitor)# monitor counter err-pkt-from-xbar 1

 

switch(config-port-monitor)# counter err-pkt-from-xbar 1 poll-interval seconds delta rising-threshold eventcount1 event event-id

Activates the err-pkt-from-xbar counter.

Specifies the delta err-pkt-from-xbar counter, poll interval in seconds, the thresholds in the count of error frame events, and the event IDs of events.

Step 7

switch(config-port-monitor)# monitor counter err-pkt-to-xbar 1

 

switch(config-port-monitor)# counter err-pkt-to-xbar 1 poll-interval seconds delta rising-threshold eventcount1 event event-id falling-threshold 2 eventcount2 event event-id

Activates the err-pkt-to-xbar counter.

Specifies the delta err-pkt-to-xbar counter, poll interval in seconds, the thresholds in the count of error frame events, and the event IDs of events.

Step 8

switch(config-port-monitor)# counter invalid-crc poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta invalid CRC, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.

Step 9

switch(config-port-monitor)# counter invalid-words poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta invalid words, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.

Step 10

switch(config-port-monitor)# counter link-loss poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta link failure counter, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.

Step 11

switch(config-port-monitor)# counter protocol-error poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta protocol error poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.

Step 12

switch(config-port-monitor)# counter rx-performance poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta Rx counter poll interval in seconds and thresholds in percentage.

Step 13

switch(config-port-monitor)# counter signal-loss poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta signal loss poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.

Step 14

switch(config-port-monitor)# counter state-change poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta state change poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.

Step 15

switch(config-port-monitor)# counter sync-loss poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta sync loss poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered.

Step 16

switch(config-port-monitor)# counter tx-performance poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold 2 percentage2 event event-id

Specifies the delta Tx counter poll interval in seconds and thresholds in percentage.

Step 17

switch(config-port-monitor)# no counter sync-loss

Reverts to the default policy for sync loss performance counter values.

Step 18

switch(config-port-monitor)# no counter tx-performance

Reverts to the default policy for Tx performance counter values.

Step 19

switch(config-port-monitor)# monitor counter rx-datarate

Turns on Rx performance counter.

switch(config-port-monitor)# monitor counter tx-datarate

Turns on Tx performance counter.

switch(config-port-monitor)# no monitor counter tx-datarate

Turns off Tx performance counter.

switch(config-port-monitor)# no monitor counter sync-loss

Turns off monitoring sync loss.

switch(config-port-monitor)# no monitor counter state-change

Turns off monitoring state change.

5.The error-pkt-port counter, the err-pkt-from xbar counter, and the err-pkt-to-xbar counter are all ASIC counters. All ASIC counters are turned off by default. The Asic counters are queried every 10 seconds. If the ASIC corresponding to a specific ASIC counter sends or receives any error packets during a 10-second interval, an error frame event occurs during the interval for that counter.

6.Falling-threshold value should be less than the rising-threshold value.

Activating a Port Monitor Policy

To activate a port monitor policy, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# port-monitor activate policyname

Activates the specified port monitor policy.

switch(config)# port-monitor activate

Activates the default port monitor policy.

switch(config)# no port-monitor activate policyname

Deactivates the specified port monitoring policy.

Configuring a Port Monitor Port Guard

To configure a port monitor policy, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# port-monitor name policyname

Specifies the policy name and enters the port monitoring policy configuration mode.

switch(config)# no port-monitor name policyname

Removes the policy.

Step 3

switch(config-port-monitor)# counter link-loss poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold percentage2 event event-id

portguard flap

Specifies the delta link loss, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered. It also specifies that the port is flappped (is up or down) when the event occurs.

Step 4

switch(config-port-monitor)# counter link-loss poll-interval seconds delta rising-threshold percentage1 event event-id falling-threshold percentage2 event event-id

portguard errordisable

Specifies the delta link loss, poll interval in seconds, the thresholds in percentage, and the event IDs of events to be triggered. It also specifies that the interface is down (error disabled) when the event occurs.


Note By default, the port monitor port guard is disabled. To enable this feature, you must explicitly configure the port monitor port guard feature on a particular counter by performing Step 3 or Step 4.


Enabling Port Group Monitor

To enable port group monitor, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# port-group-monitor enable

Enables (default) port group monitoring.

switch(config)# no port-group-monitor enable

Disables port group monitoring.

Configuring a Port Group Monitor Policy

To configure port group monitor policy, follow these steps:

 

 
Command
Purpose

Step 1

switch# config t

Enters configuration mode.

Step 2

switch(config)# port-group-monitor name policyname

Specifies the policy name and enters the port group monitoring policy configuration mode.

switch(config)# no port-group-monitor name policyname

Removes the policy.

Step 3

switch(config-port-group-monitor)# counter rx-performance poll-interval seconds delta rising-threshold percentage1 falling-threshold percentage2

Specifies the delta Rx counter poll interval in seconds and thresholds in percentage.

switch(config-port-group-monitor)# counter tx-performance poll-interval seconds delta rising-threshold percentage1 falling-threshold percentage2

Specifies the delta Tx counter poll interval in seconds and thresholds in percentage.

switch(config-port-group-monitor)# no counter tx-performance

7Reverts to the 8default policy.

Step 4

switch(config-port-group-monitor)# monitor counter rx-performance

Turns on Rx performance monitoring.

switch(config-port-group-monitor)# monitor counter tx-performance

Turns on Tx performance monitoring.

switch(config-port-group-monitor)# no monitor counter tx-performance

9Turns off Tx performance monitoring.