Technical Specifications

Environmental and Physical Specifications

This table describes the environmental specifications.

Table 1. Environmental Specifications for the Switch

Environmental Ranges

Operating temperature

1
  • 23 to 104°F (–5 to 40°C): C9200CX-8UXG-2X and C9200CX-8UXG-2XH

  • 23 to 113°F (–5 to 45°C): All other switch models.

Note

 
  • Always measure the operating temperature within 1 inches from the sides of the switch.

  • Note that the maximum operating temperature can be limited by the type of SFP used. Refer to the Datasheet for information about specific restrictions.

Storage temperature

–40 to 158°F (–40 to 70°C)

Relative humidity

5 to 90% (non-condensing)

Operating altitude

Up to 5000 ft (1500 m)

Storage altitude

Up to 15,000 ft (4500 m)

1 Minimum ambient temperature for cold start is 32°F (0°C)
Table 2. Physical Specifications of the Switch

C9200CX-8P-2X2G

1.73 x 10.6 x 9.6 in. (4.4 x 26.9 x 24.4 cm)

C9200CX-12P-2X2G

1.73 x 10.6 x 9.6 in. (4.4 x 26.9 x 24.4 cm)

C9200CX-8P-2XGH

1.73x 10.6 x 9.6 in. (4.4x 26.9 x 24.4 cm)

C9200CX-12P-2XGH

1.73x 10.6 x 9.6 in. (4.4x 26.9 x 24.4 cm)

C9200CX-12T-2X2G

1.73 x 10.6 x 6.5 in. (4.4 x 26.9 x 16.5 cm)

C9200CX-8UXG-2X

1.73x 10.6 x 9.6 in. (4.4x 26.9 x 24.4 cm)

C9200CX-8UXG-2XH

1.73x 10.6 x 9.6 in. (4.4x 26.9 x 24.4 cm)

Table 3. Weight Measurements

Switch Model

Weight

C9200CX-8P-2X2G

6.6 lb (2.99 kg)

C9200CX-12P-2X2G

6.6 lb (2.99 kg)

C9200CX-8P-2XGH

6.6 lb (2.99 kg)

C9200CX-12P-2XGH

6.6 lb (2.99 kg)

C9200CX-12T-2X2G

4.1 lb (1.86 kg)

C9200CX-8UXG-2X

7.0 lb (3.18 kg)

C9200CX-8UXG-2XH

7.0 lb (3.18 kg)

High-Voltage AC Power Supply

The following table lists specifications for the high-voltage alternating current input power supply:

Table 4. HVAC Power Supply Specification

Specification

Description

AC-input voltage

  • 100 VAC to 277 VAC nominal.

  • 90 VAC to 305 VAC full range

AC-input current

3.55 to 1.37A

AC-input frequency

50/60Hz nominal (47 to 63Hz full range)

Power supply output

  • -55VDC/4.5A (min)

  • 5VDC/14A (max)

Output holdup time

20ms (min)

Temperature

-5C to 55C

Humidity

5% to 90%

Altitude

5000 meters

High-Voltage DC Power Supply

The following table lists the high-voltage direct current (HVDC) input power supply:

Table 5. HVDC Power Supply Specification

Specification

Description

DC-input voltage

120 VDC (min) to 418 VDC (max)

DC-input current

3.17-0.89A

Power supply output

  • -55VDC/4.5A (min)

  • 5VDC/14A (max)

Output holdup time

20ms (min)

Temperature

-5C to 55C

Humidity

5% to 90%

Altitude

5000 meters