System Environmental Specifications

This chapter describes the environmental specifications for Cisco NCS 1010.

System Environmental Specifications

The Cisco NCS 1010 has the following environmental specifications:

Table 1. Environmental Specifications for Cisco NCS 1010

Environmental Conditions

Operating Duration

Operating Temperature

Operating Altitude

Operating at high or low temperature

Short term1

–5–55° Celsius

1800 m

Normal Operation

Long term (365 days)

5–40° Celsius

1800 m

Fan failure2

Short term

5–40° Celsius

1800 m

1 As per NEBS GR-63-CORE, short term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in one year (This refers to a total of 360 hours in any given year, but not more than 15 occurrences during that one year)
2 A fan failure means that one of the fans on both fan trays stopped working (5 out of 6 fans are working). Replace a failed fan tray as per the replacement procedure within the OIR time limits.