Requirements for Orchestrator
Note |
This section describes additional requirements and guidelines if you plan to enable the Orchestrator service. Ensure that you have already satisfied the platform-level requirements described in the Prerequisites and Guidelines section. |
-
Starting with Nexus Dashboard release 3.1.1, Cisco DC App Center connectivity has been removed from Nexus Dashboard because downloading the services separately is no longer required.
To deploy Orchestrator, download the unified installation image from the Software Download page; individual services’ installation images are no longer available from the Cisco DC App Center.
-
If you are deploying Nexus Dashboard Orchestrator to manage Cisco ACI fabrics, you can establish connectivity from either the data interface or the management interface to either the in-band or out-of-band (OOB) interface of each site's APIC or both.
Note that if the fabric connectivity is from the Nexus Dashboard's management interface, you must configure specific static routes or ensure that the management interface is part of the same IP subnet of the APIC interfaces.
-
If you are deploying Nexus Dashboard Orchestrator to manage Cisco NDFC fabrics, the data network must have in-band reachability for Cisco NDFC sites.
-
Connectivity between the nodes is required on both networks with the following additional round trip time (RTT) requirements:
Table 1. Orchestrator RTT Requirements Connectivity
Maximum RTT
To any managed APIC sites
500 ms
To any managed NDFC sites
150 ms