Troubleshooting Transient Faults


Transient faults can occur during initial set up and discovery or when a server or virtual machine starts up. You can typically ignore these transient faults, as Cisco UCS Manager clears them automatically.

This chapter includes the following sections:

Initial Setup and Discovery Faults

Virtual Machine Startup Faults

Initial Setup and Discovery Faults

Table 5-1 describes the transient faults that you may see during the initial setup and discovery process. The Cisco UCS Manager clears these faults. If you see them during the initial setup or discovery process, you can safely ignore these faults.

Table 5-1 Transient Faults that Occur during Initial Setup and Discovery Process

Fault Code
Fault Text
Description 

F16581

[FSM:STAGE:RETRY:]: user configuration 
to secondary(FSM-STAGE:sam:dme: 
AaaUserEpUpdateUserEp:SetUserPeer)

The FSM could not send the user configuration to the subordinate fabric interconnect during the initial cluster configuration or the setup.

F16745

[FSM:STAGE:RETRY:]: QoS Classification 
Definition classification configuration 
on 
secondary(FSM-STAGE:sam:dme:QosclassDef
initionConfigGlobalQoS:SetPeer)

The FSM could not send the quality of the service configuration to the subordinate fabric interconnect during the initial cluster configuration or the setup.

F16725

[FSM:STAGE:RETRY:]: VM profile 
configuration on external VM 
manager(FSM-STAGE:sam:dme:VnicProfileSe
tConfigVmm:SetLocal)

The FSM could not send the VM profile configuration to the the subordinate fabric interconnect during the initial cluster configuration or the setup.

F16580

[FSM:STAGE:RETRY:]: realm configuration 
to secondary(FSM-STAGE:sam:dme: 
AaaRealmUpdateRealm:SetRealmPeer)

The FSM could not send the security configuration to the subordinate fabric interconnect during the initial cluster configuration or the setup.

F16724

[FSM:STAGE:RETRY:]: external VM manager 
configuration on local 
fabric(FSM-STAGE:sam:dme:ExtvmmEpConfig
:SetLocal)

The FSM could not send the VM manager configuration to the primary fabric interconnect during the initial cluster configuration or the setup.

F16579

[FSM:STAGE:RETRY:]: external aaa server 
configuration to secondary(FSM-STAGE: 
sam:dme:AaaEpUpdateEp:SetEpPeer)

The FSM could not send the security configuration to the subordinate fabric interconnect during the initial cluster configuration or the setup.

F16749

[FSM:STAGE:RETRY:]: Uplink eth port 
configuration on B(FSM-STAGE: 
sam:dme:SwEthLanBorderDeploy: 
UpdateConnectivity)

The FSM could not send the eth-uplink configuration to the fabric interconnects during the initial cluster configuration or the setup.

F16749

[FSM:STAGE:RETRY:]: internal network 
configuration on B(FSM-STAGE: 
sam:dme:SwAccessDomainDeploy: 
UpdateConnectivity)

The FSM could not send the internal network configuration to the fabric interconnects during the initial cluster configuration or the setup.

F16749

[FSM:STAGE:RETRY:]: Uplink fc port 
configuration on B(FSM-STAGE:sam: 
dme:SwFcSanBorderDeploy: 
UpdateConnectivity)

The FSM could not send the fibre channel uplink configuration to the fabric interconnects during the initial cluster configuration or the setup.

F16680

[FSM:STAGE:RETRY:]: Enable virtual 
interface on local fabric interconnect 
(FSM-STAGE:sam:dme:MgmtIfEnableVip: 
Local)

The FSM could not send the virtual interface configuration to the fabric interconnects during the initial cluster configuration or the setup.

F16579

[FSM:STAGE:RETRY:]: keyring 
configuration on secondary(FSM-STAGE: 
sam:dme:PkiEpUpdateEp:SetKeyRingPeer)

The FSM could not send the security configuration to the subordinate fabric interconnect during the initial cluster configuration or the setup.

F16539

[FSM:STAGE:RETRY:]: Fabric interconnect 
mode configuration to 
primary(FSM-STAGE: 
sam:dme:FabricLanCloudSwitchMode: 
SwConfigPeer)

The FSM could not send the end-host mode configuration on to the primary fabric interconnect during the initial cluster configuration or the setup.

F0429

Fabric Interconnect A, HA functionality 
not ready

The cluster configuration cannot be completed until the chassis discovery is completed.

F0400

Chassis 1 connectivity configuration: 
un-acknowledged

The Cisco UCS Manager discovered the chassis with only one link in the first attempt although the chassis discovery policy is configured for four links. THe Cisco UCS Manager reacknowledges the chassis to activate the other links.

F0401

IOM 1/2 (B) current connectivity does 
not match discovery policy: 
unsupported-connectivity

The Cisco UCS Manager discovered the chassis with only one link in the first attempt although the chassis discovery policy is configured for four links.

The Cisco UCS Manager can clear this fault when the communication is established between the chassis and the fabric interconnect with that link.

F0440

Chassis discovery policy conflict: Link 
IOM 1/2/2 to fabric interconnect B:1/1 
not configured

The Cisco UCS Manager discovered the chassis with only one link in the first attempt although the chassis discovery policy is configured for four links. Until the discovery is successful with that link, the remaining links cannot be marked as active.

The Cisco UCS Manager can clear this fault when the communication is established between the chassis and the fabric interconnect with that link.

F0332

AssociatePnuOSLocalDiskConfig fails 
with Service-Unavailable 

During discovery, the server association failed due to an error when configuring the local disk controller.

The associated remote invocation error code is 4106.

F0277

ether port 1 on fabric interconnect B 
oper state: link-up, reason: FEX not 
configured

The Cisco UCS Manager discovered the chassis with only one link in the first attempt although the chassis discovery policy is configured for four links. Until the discovery is successful with that link, the remaining links cannot be marked as active.

F0276

ether port 4 on fabric interconnect B 
oper state: link-down, reason: Link 
failure or not-connected

One or more of the links on the chassis flapped during the initial discovery. This fault is generated when the link is down during the flapping.

F0206

Adapter 1/2/1 is unreachable

During discovery, the adapter information cannot be accessed from the server. This fault clears as soon as the information is available.

F0283

VIF 1 / 2 B-42/44 down, reason: Bound 
Physical Interface Down

The internal VIF that the Cisco UCS Manager uses during discovery failed.

F0367

No link between IOM port 1/1/2 and 
fabric interconnect A:1/2

The ethernet server ports flapped on the fabric interconnect during the initial discovery, because the discovery policy was configured for more than one link.

The Cisco UCS Manager clears this fault when the initial discovery succeeds with one link and the other links can be marked as active.

F0399

Current connectivity for chassis 1 does 
not match discovery policy: 
unsupported-connectivity

The Cisco UCS Manager discovered the chassis with only one link in the first attempt although the chassis discovery policy is configured for four links. Until the discovery is successful with that link, the remaining links cannot be marked as active.

F16520

[FSM:STAGE:RETRY:]: Identify pre-boot 
environment agent on server 1/2 
(FSM-STAGE:sam:dme:ComputeBlade 
Discover:PnuOSIdent)

The FSM failed to identify the pre-boot environment on the server during discovery.

F77960

[FSM:STAGE:REMOTE-ERROR]: Result: 
end-point-unavailable Code: unspecified 
Message: Waiting for BIOS POST 
Completion information from 
IBMC(sam:dme:ComputeBladeDiscover: 
BiosPostCompletion)

The FSM did not receive a response from the server during discovery and is waiting for the BIOS POST completion information.

F0320

Server 1/1 (service profile: ) has an 
invalid FRU: 
mismatch-identity-unestablishable

The Cisco UCS Manager could not identify the FRUs from the servers during initial discovery.

F77959

[FSM:STAGE:REMOTE-ERROR]: Result: 
unidentified-fail Code: 
ERR-0505-IBMC-fru-retrieval-error 
Message: Could not get Fru from 
7f060101, 
dn=fabric/server/chassis-1/slot-1 
(sam:dme:FabricComputeSlotEpIdentify:Ex
ecuteLocal)

The Cisco UCS Manager could not identify the FRUs from the servers during initial discovery.

F16406

[FSM:STAGE:RETRY:]: triggering chassis 
discovery via IOM 
1/2(right)(FSM-STAGE:sam:dme:EquipmentI
OCardFeConn:DiscoverChassis)

In a cluster configuration, after the Cisco UCS Manager discovers the chassis through the I/O module connected to the primary fabric interconnect, it raises discovery through the I/O module connected to the secondary fabric interconnect.


Virtual Machine Startup Faults

When you power on a virtual machine on a server that has network adaptors connected to a distributed virtual wwitch through a port profile, the Events tab of the VMware vCenter may display the following event:

Virtual machine powered On with vNICs connected to dvPorts that have a port level 
configuration, which might be different from the dvPort group configuration. 

If you see this event, you can safely ignore it.