Enabling BIOS Parameters
Before you begin
-
You must have a BIOS policy that is already created with the following options enabled:
-
For Intel based servers, Intel VT for directed IO under Intel Directed IO tab.
-
For AMD based servers, IOMMU and SVM Mode under Processor tab.
To update BIOS options, see, Cisco UCS Manager Server Management Guide.
-
-
You must have a service profile already created for SR-IOV configuration. To create a Service Profile see Cisco UCS Manager Server Management Guide. Once the Service Profile is created, follow the steps in this procedure to enable the BIOS policy.
Procedure
Step 1 |
In the Navigation pane, click Servers. |
Step 2 |
Expand . |
Step 3 |
Expand the node for the organization that includes the service profile for which you want to enable SR-IOV BIOS parameters. If the system does not include multi-tenancy, expand the root node. |
Step 4 |
Click the service profile for which you want to enable SR-IOV BIOS parameters. |
Step 5 |
In the Work pane, click the Policies tab. |
Step 6 |
On the Policies tab, expand BIOS Policy. |
Step 7 |
From the BIOS Policy drop-down list, select the BIOS policy that you have created for SR-IOV configuration. Ensure that the BIOS policy selected satisfies the pre-requisites for this procedure. |
Step 8 |
Save changes and click Yes to reboot the server. |