Messages and Recovery Procedures


This chapter lists the switch system messages by facility. Within each facility, the messages are listed by severity levels 0 to 7. The highest severity level is 0, and the lowest severity level is 7. Each message is followed by an explanation and a recommended action.


Note The messages listed in this chapter do not include the date/time stamp designation; the date/time stamp designation is displayed only if the software is configured for system log messaging.


For Cisco IOS system messages not contained in this publication, refer to this document:

http://www.cisco.com/en/US/docs/ios/system/messages/guide/consol_smg.html

ACE Messages

This section contains Allegro Crypto Engine (ACE) messages.

ACE-3

Error Message    %ACE-3-NOENGINESLOT: Interface [chars] has no crypto engine slot

Explanation    This message appears when an IKE SA was requested for a given interface, but no crypto engine slot was assigned to that interface. [chars] is the name of the interface that is missing the crypto engine slot command.

Recommended Action    Configure the interface in question with the crypto engine [sub]slot command.

Error Message    %ACE-3-OUTOFID_RL: Too may [chars] IDs in the system. Cannot allocate 
a new one

Explanation    All the IDs of the specified type are in use.

Recommended Action    Reduce the traffic load, the number of IPsec tunnels, or the frequency of changing the value of a cryptographic key. If this message appeared under light traffic conditions, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

ACE-6

Error Message    %ACE-6-SWITCHOVER: VPN-SM switchover: [dec]/[dec] has been [chars] 
[dec]/[dec] 

Explanation    A module-to-module switchover has occurred. System performance is not affected.

Recommended Action    No action is required.

Error Message    %ACE-6-UNEXP_INBOUND_IPSEC: [chars]: received unexpected IPsec packet: 
src IP: [IP_address]; dst IP: [IP_address]; (count=[dec]) 

Explanation    An IPsec packet was unexpectedly forwarded to the RP.

Recommended Action    If this message appears when booting the router and enabling the hardware crypto accelerator, then this message is normal and can be safely ignored. Otherwise, copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.

Error Message    %ACE-6-UNEXP_OUTBOUND_IPSEC: [chars]: received unexpected IPsec 
packet: src IP: [IP_address]; dst IP: [IP_address]; firsthop/lasthop = 
[chars]/[chars] (count=[dec])

Explanation    An IPsec packet was unexpectedly forwarded to the RP.

Recommended Action    If this message appears when booting the router and enabling the hardware crypto accelerator, then this message is normal and can be safely ignored. Otherwise, copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.

AFLSEC Messages

This section contains Accelerated Flow Logging Security (AFLSEC) messages.

AFLSEC-6

Error Message    %AFLSEC-6-OALDP: [chars] icmp [IP_address] -> [IP_address] 
([dec]/[dec]), [dec] packet[chars]

Explanation    Packets matching the Optimized ACL Logging (OAL) criteria were detected.

Recommended Action    No action is required.

Error Message    %AFLSEC-6-OALNP: [chars] ip protocol=[dec]  [IP_address] -> 
[IP_address], [dec] packet[chars]

Recommended Action    Packets matching the OAL criteria were detected.

Recommended Action    No action is required.

Error Message    %AFLSEC-6-OALP: [chars] [chars] [IP_address]([dec]) -> 
[IP_address]([dec]), [dec] packet[chars]

Explanation    Packets matching the OAL criteria were detected.

Recommended Action    No action is required.

Error Message    %AFLSEC-6-OALRL: Oal logging rate-limited or missed [dec] 
packet[chars] 

Explanation    Some packet-matching logs were missed because the log messages were rate-limited, the cache table was full, or no log buffers were available.

Recommended Action    No action is required.

Error Message    %AFLSEC-6-OALRP: [chars] igmp [IP_address] -> [IP_address] ([dec]), 
[dec] packet[chars] 

Explanation    Packets matching the OAL criteria were detected.

Recommended Action    No action is required.

AP Messages

This section contains Authentication Proxy (AP) messages.

AP-1

Error Message    %AP-1-POSTURE_POLICY_ERROR: POLICY=[chars]| POLICYNAME=[chars]| 
IP=[IP_address]| ERROR=<[chars][chars]> 

Explanation    The specified policy was not applied for the given host IP due to the reason specified as Error.

Recommended Action    When the "POLICY" character string is "HOST ACL," verify that an input access control list (ACL) is defined and configured on the interface. A "URL REDIRECT ACL" policy needs a URL-redirect vendor-specific attribute (VSA) to have an associated access control list URL-redirect-ACL VSA that can be used to determine HTTP redirect criteria. HTTP packets that match the ACL are subject to redirection. When a URL-redirect-ACL access control list is not specified or is not configured, the host will not be set up for HTTP redirection.

AP-4

Error Message    %AP-4-AUTH_PROXY_NOMEM: Sufficient memory was not available to [chars] 

Explanation    There was not enough memory to perform the specified operation.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message    %AP-4-POSTURE_EXCEED_MAX_INIT: Exceeded maximum limit ([dec]) on 
entires in authentication proxy posture cache in initializing state 

Explanation    The number of entries that are in the Authentication Proxy posture cache and in an initializing state has exceeded the maximum limit.

Recommended Action    This condition might indicate a denial of service (DoS) attack. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

AP-6

Error Message    %AP-6-POSTURE_DOWNLOAD_ACL: Send AAA request to download ([chars]) 
named access control list 

Explanation    The system has sent a request to AAA to retrieve the contents of the specified downloadable ACL.

Recommended Action    This message is informational. No action is required.

Error Message    %AP-6-POSTURE_POLICY: [chars] [chars] ([chars]) policy for host 
([IP_address]) 

Explanation    This message specifies the policy that was enforced for or removed from the specified host. The policy can be either an ACL or a URL to which any intercepted HTTP traffic is redirected.

Recommended Action    This message is informational. No action is required.

Error Message    %AP-6-POSTURE_START_VALIDATION: IP=[IP_address]| Interface=[chars] 

Explanation    The system has created an entry for the host in the Authentication Proxy posture cache and has initiated the posture validation process.

Recommended Action    This message is informational. No action is required.

Error Message    %AP-6-POSTURE_STATE_CHANGE: IP=[IP_address]| STATE=[chars] 

Explanation    The state of posture validation changed for the specified host in the Authentication Proxy posture validation cache.

Recommended Action    This message is informational. No action is required.

ATMSPA Messages

This section contains ATM Shared Port Adapter (ATMSPA) messages.

ATMSPA-2

Error Message    %ATMSPA-2-INITFAIL: [chars] - Init Failed return code: [int] 

Explanation    The SPA failed to complete hardware initialization. One of the devices in the SPA failed to initialize successfully. Information about the failed device is specified in the message text on the console or in the system log.

Recommended Action    Power down and reseat the indicated SPA card. If the condition persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

ATMSPA-3

Error Message    %ATMSPA-3-DATA_ERROR: [chars] Error [hex] [chars] 

Explanation    A data path protocol violation or sequence error has been detected. The message text on the console or in the system log provides more information about the specific nature of the error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %ATMSPA-3-FATAL_ERROR: occurred on [chars]. Resetting SPA 

Explanation    The SPA has been reset because of a critical error in one of its devices. The error could be either a single occurrence of an event or multiple occurrences within a period of time. The message text on the console or in the system log provides more information about the specific nature of the error.

Recommended Action    If the SPA is reset more than once, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %ATMSPA-3-FPD_VER_DEPENDENCY_NOTE: Cannot perform the requested FPD 
update operation because [chars] in subslot [int]/[int] has incompatible HW 
version [int].[int] with FPD image version [dec].[dec] for FPD ID [dec]. Only image 
version greater than [int].[int] can be used in the update operation of [chars] 
with HW version greater than [int].[int]. 

Explanation    The version of the field-programmable device (FPD) image from the FPD image bundle or package is not compatible with the hardware version of the target card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %ATMSPA-3-GEN_ERROR: [chars] Error [hex] [chars] 

Explanation    The error that is specified in the message has been detected.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %ATMSPA-3-HW_ERROR: [chars] Error [hex] [chars] 

Explanation    A hardware error has been detected. The message text on the console or in the system log provides more information about the specific nature of the error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %ATMSPA-3-QOS_ALLOC_FAILED: [chars] [chars] [chars]: [dec] 

Explanation    Traffic-shaping parameters could not be configured because the number of unique shaping parameters that are configured on the PVCs or PVPs in this specified ATM SPA is over the maximum limit. The maximum number of unique shaping parameters that can be configured on the PVCs or PVPs is 4096.

Recommended Action    Ensure that the total number of unique shaping parameters that are configured on both PVCs and PVPs does not exceed the maximum limit of 4096.

Error Message    %ATMSPA-3-SW_ERROR: [chars] Error [hex] [chars] 

Explanation    A software error has been detected. The message text on the console or in the system log provides more information about the specific nature of the error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %ATMSPA-3-VCQ_ERROR: [chars]: VC queue configuration failed due to 
un-initialized queue table(global identifier [dec]) 

Explanation    The software configuration of a VC queue failed because of an uninitialized queue table.

Recommended Action    Attempt to perform a soft OIR operation by entering the command that is described in the software configuration guide for the shared port adapter. If the condition persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

ATMSPA-4

Error Message    %ATMSPA-4-VCSETUP: [chars]: VC setup command received on the LC for an 
existing VC (VCD [dec]) 

Explanation    A command to set up a VC has been received for a VC that has already been set up and configured by a previous setup VC command from the route processor (RP). A duplicate setup command may indicate that the RP did not receive a response from the line card for the previous setup command.

Recommended Action    No action is required.

Error Message    %ATMSPA-4-VCTEARDOWN: [chars]: VC tear down command received on the LC 
for a non-existing VC (VCD [dec]) 

Explanation    The VC does not exist on the line card. The VC may have been torn down by a previous teardown command from the RP. A duplicate teardown command may indicate that the RP did not receive a response from the line card for the previous teardown command.

Recommended Action    No action is required.

BGP Messages

This section contains Border Gateway Protocol (BGP) messages.

BGP-3

Error Message    %BGP-3-ADDPATH: Number of paths for [chars] exceeded allowed maximum 
of [dec] 

Explanation    BGP is receiving the same prefix from too many neighbors.

Recommended Action    Restrict the number of neighbors advertising the same prefix by implementing inbound filters.

Error Message    %BGP-3-MAXPFXEXCEED: No. of prefix received from [chars][chars][chars] 
(afi [dec]): [dec] exceed limit [dec] 

Explanation    The number of prefixes received from a neighbor has exceeded a configured limit.

Recommended Action    Check the number of prefixes received from the neighbor and determine whether the limit should be increased.

Error Message    %BGP-3-PER_VRF_AGGR: pervrfaggr label: [chars]

Explanation    This message might appear when a prefix changes to a connected or BGP aggregate type. The Tag Forwarding Information Base (TFIB) asks for a label for a prefix in the VRF routing table. The per-VRF aggregate label will be assigned to the connected or BGP aggregate prefix when BGP runs a best-path calculation.

Recommended Action    No action is required. If this message recurs, contact your Cisco technical support representative.

BGP-4

Error Message    %BGP-4-MAXPFX: No. of prefix received from [chars][chars][chars] (afi 
[dec]) reaches [dec], max [dec] 

Explanation    The number of prefixes received from a neighbor has reached a warning limit.

Recommended Action    Check the number of prefixes received from the neighbor and determine whether the limit should be increased.

C6K_MPLS_COMMON Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router LAN and WAN Multiprotocol Label Switching (C6K_MPLS_COMMON) messages.

C6K_MPLS_COMMON-3

Error Message    %C6K_MPLS_COMMON-3-L2_CONFIG_NOT_RECOMMENDED: xconnect is configured 
on interface vlans and WAN interfaces are facing the MPLS Core. Do not configure 
LAN interfaces facing the MPLS Core. 

Explanation    An attempt was made to configure a LAN interface to face the MPLS core. The current network configuration has cross-connection services configured on interface VLANs and has WAN interfaces facing the MPLS core.

Recommended Action    Do not configure MPLS on LAN interfaces facing the MPLS core if the network has cross-connect services configured on an interface VLAN and WAN interfaces that face the MPLS core.

Error Message    %C6K_MPLS_COMMON-3-L3_CONFIG_NOT_RECOMMENDED: LAN interfaces are 
facing the MPLS Core. Do not configure xconnect on interface vlans. 

Explanation    An attempt was made to configure a cross-connection service on an interface VLAN. The current network configuration has MPLS configured on a LAN interface that is facing the MPLS core.

Recommended Action    Do not configure cross-connection services on an interface VLAN if the network has MPLS configured on a LAN interface.

Error Message    %C6K_MPLS_COMMON-3-OSM_BB1_CONFIG_UNSUPPORTED: The maximum label 
range configured for this system exceeds the [int] limit supported by the module 
in slot [int]. For proper MPLS functionality on any of the interfaces on this 
module the maximum label range should be set to [int]. 

Explanation    The OSM cannot support the MPLS label range configured for this system.

Recommended Action    Change the maximum MPLS label range by using the mpls label range command.

Error Message    %C6K_MPLS_COMMON-3-VPLS_CONFIG_EXCEEDED: The number of EoMPLS/VPLS VCs 
exceeded the maximum supported on [IP_address]/[int]. 

Explanation    The number of destination routers or the global number of virtual circuits exceeded the maximum limit supported by the device.

Recommended Action    Refer to network configuration guidelines for the maximum limits.

C6K_MPLS_LC Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router Multiprotocol Label Switching (MPLS) switch processor or module (C6K_MPLS_LC) messages.

C6K_MPLS_LC-3

Error Message    %C6K_MPLS_LC-3-MALLOCFAIL: failed to create [chars] 

Explanation    The system failed to allocate memory for an MPLS entry for the incoming label. Some MPLS packets might be forwarded by the software.

Recommended Action    Reduce other system activity to ease memory demands. If necessary, increase system memory. When more memory is available, wait for a few minutes and enter the clear ip route command. If sufficient memory has not been made available, this message will be displayed again. If this problem persists, contact your Cisco technical support representative.

Error Message    %C6K_MPLS_LC-3-REWRITEFAIL: null adj for incoming label [dec] 

Explanation    The specified incoming label has a NULL adjacency entry. The hardware adjacency entry might not be programmed because the incoming label has the NULL adjacency entry. This condition is an internal software error.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Contact your Cisco technical support representative with the output of the show mpls forwarding-table labels command.

Error Message    %C6K_MPLS_LC-3-TCAMFAIL: failed to insert label [dec] to TCAM

Explanation    The system failed to allocate TCAM entry for an MPLS entry for the specified label. The TCAM might be full. Some MPLS packets might be forwarded by the software.

Recommended Action    Reduce the number of routes in the system to free up TCAM space. When enough free TCAM space is available, the software starts the TCAM recovery mechanism automatically. The TCAM recovery mechanism reinstalls the MPLS label entries that previously failed.

C6K_MPLS_RP Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router LAN Multiprotocol Label Switching (C6K_MPLS_RP) messages.

C6K_MPLS_RP-2

Error Message    %C6K_MPLS_RP-2-NO_IP_ACL_RSVD_VLAN: IP ACL features will not be 
applied to MPLS->IP packets due to a lack of internal VLAN resources 

Explanation    The total number of VLANs in use might have exceeded 4096. The VLAN resources are shared by VLANs used for SVI, VLANS used for subinterfaces, hidden VLANs used for routed ports, and internal VLANs used for some VRFs. An internal VLAN is needed when an IP ACL feature is applied to a VRF interface. If the total number of VLANs in use exceeds 4096, no more internal VLANs can be allocated, so IP ACL features will not be applied to MPLS-to-IP packets.

Recommended Action    Reduce the total number of VLANs in use by removing SVI interfaces, subinterfaces, and/or VRF interfaces.

Error Message    %C6K_MPLS_RP-2-NO_IP_QOS_RSVD_VLAN: IP QoS features will not be 
applied to MPLS->IP packets due to a lack of internal VLAN resources 

Explanation    The total number of VLANs in use might have exceeded 4096. The VLAN resources are shared by VLANs used for SVI, VLANS used for subinterfaces, hidden VLANs used for routed ports, and internal VLANs used for some VRFs. An internal VLAN is needed when an IP QoS feature is applied to a VRF interface. If the total number of VLANs in use exceeds 4096, no more internal VLANs can be allocated, so IP QoS features will not be applied to MPLS-to-IP packets.

Recommended Action    Reduce the total number of VLANs in use by removing SVI interfaces, subinterfaces, and/or VRF interfaces.

C6K_MPLS_RP-3

Error Message    %C6K_MPLS_RP-3-L2_CONFIG_NOT_RECOMMENDED: xconnect is configured on 
interface vlans and WAN interfaces are facing the MPLS Core. Do not configure LAN 
interfaces facing the MPLS Core.

Explanation    An attempt was made to configure a LAN interface to face the MPLS core. The current network configuration has cross-connection services configured on interface VLANs and has WAN interfaces facing the MPLS core.

Recommended Action    Do not configure MPLS on LAN interfaces facing the MPLS core if the network has cross-connection services configured on an interface VLAN and WAN interfaces that face the MPLS core.

Error Message    %C6K_MPLS_RP-3-L3_CONFIG_NOT_RECOMMENDED: LAN interfaces are facing 
the MPLS Core. Do not configure xconnect on interface vlans. 

Explanation    An attempt was made to configure a cross-connection service on an interface VLAN. The current network configuration has MPLS configured on a LAN interface that is facing the MPLS core.

Recommended Action    Do not configure cross-connection services on an interface VLAN if the network has MPLS configured on a LAN interface.

C6K_PLATFORM Messages

This section contains general Catalyst 6500 series switch and Cisco 7600 series router platform (C6K_PLATFORM) messages.

C6K_PLATFORM-0

Error Message    %C6K_PLATFORM-0-UNKNOWN_CHASSIS: The chassis type is not known.([hex]) 

Explanation    The Cisco IOS software installed on the system does not recognize the chassis type specified in the error message.

Recommended Action    Ensure that your Cisco IOS software release train supports the chassis type. Upgrade your system to the latest Cisco IOS software release in your release train.

C6K_PLATFORM-2

Error Message    %C6K_PLATFORM-2-PEER_RESET: [chars] is being reset by the [chars] 

Explanation    The local CPU is being reset by the peer CPU when the peer CPU reloads because of exceptions.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C6K_PLATFORM-3

Error Message    %C6K_PLATFORM-3-INFO1: [chars]=[hex] [chars]=[hex] 

Explanation    This message provides information regarding the internal state of the SiByte processor.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C6K_PLATFORM-4

Error Message    %C6K_PLATFORM-4-CONFREG_BREAK_ENABLED : The default factory setting 
for config register is 0x2102.It is advisable to retain 1 in 0x2102 as it prevents 
returning to ROMMON when break is issued.

Explanation    The SP configuration register has been changed from the default factory setting of 0x2102 to another hexadecimal value.

Recommended Action    No action is required.

Error Message    %C6K_PLATFORM-4-ENVMON: System shutdown due to temperature alarms is 
[chars]. 

Explanation    The system has a configuration to shut down a module if its operating temperature exceeds a temperature threshold. This configuration has been bypassed, and a module will still operate in an over-temperature condition. Operating at an over-temperature condition can damage the hardware.

Recommended Action    Do not override the sensor alarms that act on an over-temperature condition. Enter the environment-monitor shutdown temperature command to bring the system back to standard temperature detection.

Error Message    %C6K_PLATFORM-4-RTC_OSCILLATOR: The oscillator in the Real Time Clock 
is [chars]. Calendar [chars] be maintained during the powered down state of the 
switch. 

Explanation    A command has been entered that will cause the system calendar not to be maintained during a power down of the switch. The system date and time will require manual setting when the system is powered up during the next boot time. This command is useful to conserve the battery power of the CMOS, which is used to keep the real-time clock active while the switch is powered down. This condition is useful only if the switch is powered down for a long period of time.

Recommended Action    If the switch need not be powered down for a long period of time, remove the configuration by entering the no hw-module rtc-oscillator shutdown command.

C6K_PLATFORM-5

Error Message    %C6K_PLATFORM-5-LESS_SPACE : May not have enough space to save the 
crash info. on flash of [chars] on module: [dec]

Explanation    The flash memory device does not have enough memory to save the crash information. It is possible that crash information could not be saved on the flash memory device.

Recommended Action    Remove files from the flash memory device that may not be needed, and enter the squeeze command for the flash memory device.

Error Message    %C6K_PLATFORM-5-MISMATCH : '[chars]' device programming algorithm 
mismatch detected on [chars] (module: [dec]), formatting is recommended.

Explanation    The flash memory device programming algorithm that was written to the device when the flash memory was formatted is different from what the current running software has detected.

Recommended Action    Reformat the flash memory device. Otherwise, no action is required.

C6K_POWER Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router power (C6K_POWER) messages. For more power messages, see the "C6KPWR Messages" section of this chapter.

C6K_POWER-3

Error Message    %C6K_POWER-3-NOTIFY_FAIL: Failed to notify RP of change in operator 
status for [chars] number [dec] from '[chars]' to '[chars]' 

Explanation    The SP is unable to acquire the resources needed to notify the RP of the event specified in the error message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C6K_POWER-4

Error Message    %C6K_POWER-4-PD_NOLINKUP: The device connected to [dec]/[dec] is 
powered up but its link is not up in [dec] seconds. Therefore, power is withdrawn 
from the port. 

Explanation    The system withdrew the power that was allocated to the specified port because the port link was not operational in the specified number of seconds.

Recommended Action    Try to connect the device to a different port or connect a different device to the port specified in the message.

C6K_POWER-6

Error Message    %C6K_POWER-6-NOLPP: Because of lack of system power, devices that 
require the system to power them on may not come up within one second. 

Explanation    The local power pools have been deallocated. The module firmware cannot power up the device until it has received authorization for power allocation from the software running on the supervisor engine.

Recommended Action    No action is required.

C6K_PROCMIB Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router Process MIB SP CPU (C6K_PROCMIB) messages.

C6K_PROCMIB-3

Error Message    %C6K_PROCMIB-3-IPC_PORTOPEN_FAIL: Failed to open port while connecting 
to process statistics: error code = [chars] 

Explanation    An error occurred during an attempt to open a port for an IPC message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C6K_PROCMIB-3-IPC_TRANSMIT_FAIL: Failed to send process statistics 
update : error code = [chars] 

Explanation    An error occurred during an attempt to send an IPC message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C6K_PROCMIB-3-MALLOC_FAILURE_IPC: Failed to allocate IPC message to 
contact process 

Explanation    A memory allocation failure occurred during the processing of an IPC message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C6K_WAN_C2W Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN C2Wire (C6K_WAN_C2W) messages.

C6K_WAN_C2W-4

Error Message    %C6K_WAN_C2W-4-READERROR: C2Wire read failed reg [hex] on device 
[chars] 

Explanation    The SMbus driver failed to read from the specified C2W device.

Recommended Action    No action is required if this warning message appears occasionally. If the message appears often in a short period of time, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C6K_WAN_C2W-4-WRITEERROR: C2Wire write failed reg [hex] on device 
[chars] 

Explanation    The SMbus driver failed to write to the specified C2W device.

Recommended Action    No action is required if this warning message appears occasionally. If the message appears often in a short period of time, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C6KENV Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router environmental (C6KENV) messages.

C6KENV-2

Error Message    %C6KENV-2-BADFLOWCTRL: Module [dec] not at an appropriate hardware 
revision level to support DFC. Power denied 

Explanation    The fabric-capable module in the specified slot is not at an appropriate hardware revision level and cannot support a DFC. If a DFC is present, the module will not be activated and remains powered down.

Recommended Action    Remove the DFC to enable the module to operate at its current hardware revision level. To enable DFC operation, ensure that the module is at an appropriate hardware revision level.

Error Message    %C6KENV-2-BADFLOWCTRL_WARN: WARNING: Module [dec] not at an 
appropriate hardware revision level to support DFC3 

Explanation    The fabric-capable module in the specified slot is not at an appropriate hardware revision level to support a DFC3 or higher.

Recommended Action    When you upgrade the DFC daughter card, also upgrade the module to an appropriate hardware revision level.

Error Message    %C6KENV-2-BADPINN1: Module [dec] not at an appropriate hardware 
revision level to coexist with PFC3 system. Power denied 

Explanation    The module specified in the error message has a revision of 2.x or below. Modules with this revision will experience problems when they are used with a supervisor engine with a PFC3 installed and they should not be used.

Recommended Action    Upgrade the module to an appropriate hardware revision level.

Error Message    %C6KENV-2-BADTRANSCEIVER: Module [dec] will be power disabled because 
an inappropriate transceiver is inserted at [chars].

Explanation    An incompatible transceiver is inserted at the interface specified in the error message. This transceiver should not be used in this system.

Recommended Action    Remove the specified transceiver and restore power to the module. If this transceiver was purchased from Cisco, contact your Cisco technical support representative to get the transceiver replaced.

Error Message    %C6KENV-2-C2PLUSWITHNODB: The constellation 2 plus module in slot 
[dec] has no forwarding daughter board. Power denied 

Explanation    The module in the slot specified has no forwarding daughter card and is expected to have either a distributed, accelerated, or centralized forwarding card. This module will not be activated and will remain powered down.

Recommended Action    Enter the show module command to view error message details.

Error Message    %C6KENV-2-DFCMISMATCH: Module [dec] DFC incompatible with Supervisor 
DFC. Power denied 

Explanation    The DFC in the specified module is different from the DFC in the supervisor engine. The module will not be activated and remains powered down.

Recommended Action    Enter the show module command to view the difference between the DFC in the module and the DFC in the supervisor engine.

Error Message    %C6KENV-2-DFCMISMATCHMINOR: Module [dec] DFC installed is incompatible 
with system operating mode. Power denied. To enable Module [dec] DFC, the system 
must be reset.
WARNING: Any system reset will change the system operating mode which can result in degradation of system performance. To eliminate this from occurring, remove Module [dec] DFC or replace with a system compatible DFC.

Explanation    The DFC in the specified slot does not have the same software operating mode as the rest of the system. The DFC will remain powered down and cannot be activated.

Recommended Action    Enter the show module and show platform earl-mode commands to view the difference between the DFC in the specified slot and the operating mode of the rest of the system.

Error Message    %C6KENV-2-FANUPGREQ: Module [dec] not supported without fan upgrade 

Explanation    The supervisor engine and the DFC in the specified slot require a fan tray upgrade. A system shutdown is scheduled.

Recommended Action    Upgrade the system fan tray.

Error Message    %C6KENV-2-SHUTDOWN_NOT_SCHEDULED: Major sensor alarm for [chars] is 
ignored, [chars] will not be shutdown. 

Explanation    The system detected that the specified module should be shut down because it exceeded major sensor thresholds. However, the command that shuts down the module in the event of a major sensor alarm has been overridden, so the specified module will not be shut down. The command used to override the shutdown is no environment-monitor shutdown.

Recommended Action    Remove the configuration that bypasses the module shutdown due to sensor thresholds being exceeded. Shut down the module after removing the configuration.

C6KENV-4

Error Message    %C6KENV-4-ALARMCLR: [chars] alarm cleared 

Explanation    The specified alarm condition has been cleared. The shutdown has been cancelled.

Recommended Action    No action is required.

Error Message    %C6KENV-4-FANCOUNTFAILED: Required number of fan trays is not present 

Explanation    The system is missing the number of required fan trays to operate properly. Although this is a minor alarm, system components could overheat and be shut down.

Recommended Action    Insert the required fan tray as soon as possible.

Error Message    %C6KENV-4-FANCOUNTOK: Required number of fan trays is present 

Explanation    The number of required fan trays has been restored.

Recommended Action    No action is required.

Error Message    %C6KENV-4-FANHIOUTPUT: Version [dec] high-output fan-tray is in effect 

Explanation    The system has detected that the fan tray is a high-output (version 2) fan tray. The system has updated the cooling capacity for the fan tray.

Recommended Action    No action is required.

Error Message    %C6KENV-4-FANLOOUTPUT: Version [dec] low-output fan-tray is in effect 

Explanation    The system has detected that the fan tray is a low-output (version 1) fan tray. The system has updated the cooling capacity for the fan tray.

Recommended Action    No action is required.

Error Message    %C6KENV-4-FANPSINCOMPAT: Fan tray and power supply [dec] are 
incompatible 

Explanation    An upgrade of the power supply is required to sufficiently operate this fan tray. Although this is a minor alarm, overcurrent protection on the power supply could start without further warning.

Recommended Action    Upgrade the power supply.

Error Message    %C6KENV-4-FANVERCHK: Power-supply [dec] inserted is only compatible 
with Version [dec] fan-tray. Please make sure fan is low-output fan-tray 

Explanation    The system has detected that the fan tray is a low-output (version 1) fan tray. If the fan tray is a low-output tray, no action is required. If the fan tray is actually a high-output (version 2) fan tray, the specified power supply is not able to support the high-output fan tray.

Recommended Action    If the fan tray is a high-output (version 2) fan tray, enter the hw-module fan-tray version 2 command to update the system with the upgrade information. Replace the 1000 W or 1300 W power supply, as these two power supplies are not compatible in this chassis with the version 2 fan tray.

Error Message    %C6KENV-4-INSUFFCOOL: Module [dec] cannot be adequately cooled 

Explanation    The fan tray cannot adequately cool the specified module. Although this is a minor alarm, system components could overheat and be shut down.

Recommended Action    Upgrade the system fan tray.

Error Message    %C6KENV-4-MINORTEMPOKALARM: [chars] all temperature sensor have 
failed. If the module temperature sensor does not recover by itself, please power 
cycle the module when it is feasible 

Explanation    All module temperature sensors have failed.

Recommended Action    If the module temperature sensors do not recover, power cycle the module when possible.

Error Message    %C6KENV-4-MINORTEMPOKALARMRECOVER: [chars]. It has returned to normal 
operating status. 

Explanation    All module temperature sensors have returned to normal operating status.

Recommended Action    No action is required.

Error Message    %C6KENV-4-MINORTEMPSUPOKALARM: All temperature sensors of Supervisor 
in slot [dec] have failed. If the temperature sensor does not recover by itself, 
please power cycle the chassis when it is feasible 

Explanation    All temperature sensors have failed in the supervisor engine.

Recommended Action    If the temperature sensors do not recover, power cycle the chassis when possible.

Error Message    %C6KENV-4-MINORTEMPSUPOKALARMRECOVER: Supervisor in slot [dec] has 
returned to normal operating status. 

Explanation    The supervisor engine temperature sensors have returned to normal operating status.

Recommended Action    No action is required.

Error Message    %C6KENV-4-MINORVTTOKALARM: All the backplane vtt temperature sensor 
have failed. If the backplane vtt temperature sensor does not recover by itself, 
please power cycle the chasis when it is feasible 

Explanation    All backplane VTT temperature sensors have failed.

Recommended Action    If the backplane VTT temperature sensors do not recover, power cycle the chassis when possible.

Error Message    %C6KENV-4-MINORVTTOKALARMRECOVER: Backplane VTT has returned to normal 
operating status. 

Explanation    The backplane VTT has returned to normal operating status.

Recommended Action    No action is required.

C6KPWR Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router power (C6KPWR) messages.

C6KPWR-2

Error Message    %C6KPWR-2-INSUFFICIENTPOWER: Powering down all linecards as there is 
not enough power to operateall critical cards 

Explanation    The switch was operating with two power supplies in combined mode. One of the power supplies has failed. Available power is insufficient to support all critical service modules. Critical service modules include modules that support VPNs or IP security. If these critical modules fail, security issues could arise; therefore, all modules have been powered down.

Recommended Action    Replace the failed power supply.

Error Message    %C6KPWR-2-MAJORPOWERALARM: In the absence of power supply 1, system 
power usage exceeds allowed range of [chars]W. Power total will be reduced in [dec] 
seconds 

Explanation    The power supply in slot 2 has exceeded its allowed range, causing a major power alarm. The range is specified in the error message.

Recommended Action    Enter the show power command to determine the actual power usage. Insert a power supply in power supply slot 1, or power down some modules to reduce system power usage. If downtime can be scheduled, move the power supply from slot 2 to slot 1. If this condition persists, the environmental monitor will shut down some modules to prevent a complete power failure.

Error Message    %C6KPWR-2-MAJORPOWERALARMRECOVER: System power usage has returned to 
allowed operating range 

Explanation    System power usage has returned to the permitted operating range. The scheduled shutdown is cancelled, and the system will continue operating.

Recommended Action    No action is required.

Error Message    %C6KPWR-2-MINORPOWERALARM: In the absence of power supply 1, system 
power usage exceeds the recommended range of [chars]W 

Explanation    The power supply in slot 2 has exceeded its allowed range, causing a minor power alarm. The range is specified in the error message. Selected modules will be shut down to prevent a complete power failure.

Recommended Action    Enter the show power command to determine the actual power usage. Insert a power supply in power supply slot 1, or power down some modules to reduce system power usage. If downtime can be scheduled, move the power supply from slot 2 to slot 1.

C6KPWR-3

Error Message    %C6KPWR-3-PSUNKNOWN: Unknown power supply in slot [dec] (idprom read 
failed). 

Explanation    The IDPROM of the power supply in the specified slot cannot be read.

Recommended Action    Remove and reinsert the power supply. Fasten the screw, and attempt to operate the power supply again. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C6KPWR-4

Error Message    %C6KPWR-4-INPUTCHANGE: Power supply [dec] input has changed. Power 
capacity adjusted to [chars]W 

Explanation    The power supply in the specified slot has detected a change in its input supply. The power capacity for the power supply has been adjusted accordingly.

Recommended Action    Enter the show power command to see the current power status. Otherwise, no action is required.

Error Message    %C6KPWR-4-MAJORPOWERALARMRECOVER: System power usage has returned to 
allowed operating range 

Explanation    System power usage has returned to the allowed operating range, so the scheduled shutdown was cancelled. The system will continue operating.

Recommended Action    No action is required.

Error Message    %C6KPWR-4-MINORPOWERALARM: In the absence of power supply 1, system 
power usage exceeds the recommended range of [chars]W 

Explanation    The power supply in slot 2 has exceeded its allowed range, causing a minor power alarm. The range is specified in the error message. Selected modules will be shut down to prevent a complete power failure.

Recommended Action    Enter the show power command to determine the actual power usage. Insert a power supply in power supply slot 1, or power down some modules to reduce system power usage. If downtime can be scheduled, move the power supply from slot 2 to slot 1.

Error Message    %C6KPWR-4-MINORPOWERALARMRECOVER: System power usage has returned to 
normal operating range 

Explanation    System power usage has returned to the normal operating range.

Recommended Action    No action is required.

Error Message    %C6KPWR-4-PS1FAILALERT: Do not remove power supply 1 without inserting 
another supply. In the absence of power supply 1, system power capacity will be 
reduced to [chars]W after a [dec] second grace period. 

Explanation    The system is experiencing heavy traffic. In this condition, the single power supply should be used in slot 1 rather than in slot 2.

Recommended Action    Insert a power supply in slot 1, or move the power supply from slot 2 to slot 1.

Error Message    %C6KPWR-4-PS2ONLY: Single power supply system should utilize power 
supply slot 1 

Explanation    The system is experiencing heavy traffic. In this condition, the single power supply should be used in slot 1 rather than in slot 2.

Recommended Action    Move the power supply from slot 2 to slot 1.

Error Message    %C6KPWR-4-PSINPUTDROP: Power supply [dec] input has dropped 

Explanation    The power supply in the specified slot has detected a drop in its input supply. The power capacity for the power supply has been adjusted accordingly.

Recommended Action    Enter the show power command to see the current power status. Otherwise, no action is required.

Error Message    %C6KPWR-4-PSMISMATCH: power supplies rated outputs do not match. 

Explanation    The two power supplies in the system have different output ratings.

Recommended Action    For more efficient load sharing, use power supplies with the same output rating.

Error Message    %C6KPWR-4-PSNOREDUNDANCY: Power supplies are not in full redundancy, 
power usage exceeds lower capacity supply 

Explanation    The two power supplies in the system have different output ratings. Current power usage exceeds the capacity of the lower-rated power supply. If the higher-rated power supply fails, the lower-rated power supply will not be able to support all modules that are currently powered up.

Recommended Action    To ensure that the system power supplies are optimally redundant, use power supplies with identical output ratings or reduce system power consumption.

C7600_SIP200 Messages

This section contains SPA Interface Processor 200 (C7600_SIP200) messages.

C7600_SIP200-3

Error Message    %C7600_SIP200-3-BADIFCTRL: Corrupted sip-200 information for interface 
[chars] [[hex]] 

Explanation    The interface SIP 200 information is not valid. An internal software error has occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, collect the output of the show memory command on the line card, and contact your technical support representative with the gathered information.

Error Message    %C7600_SIP200-3-SONET_CLOCK_FAILED: SPA Sonet clock has failed (status 
= [hex]) 

Explanation    The SPA SONET clock has failed. SPAs that rely on the SPA SONET clock for proper operation, such as PoS and ATM, will be affected.

Recommended Action    If the SPA SONET clock does not recover, perform an OIR.

Error Message    %C7600_SIP200-3-SONET_CLOCK_RECOVERED: SPA Sonet clock has recovered 
(status = [hex]) 

Explanation    SPA SONET clock has recovered.

Recommended Action    No action is required.

C7600_SIP200-4

Error Message    %C7600_SIP200-4-MEM_MODULE_MISMATCH: Memory modules are not identical 

Explanation    The memory modules do not have identical parameters. This condition might impact performance.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, collect the output of show memory command on the line card, and contact your technical support representative with the gathered information.

C7600_SIP200_MP Messages

This section contains SIP 200 Multiprocessing (C7600_SIP200_MP) messages.

C7600_SIP200_MP-1

Error Message    %C7600_SIP200_MP-1-UNSAFE: Multiprocessor error on [chars] 

Explanation    The line-card CPU contains two CPU cores, one of which is the master CPU. The CPU specified in the error message attempted to perform an operation that is illegal for multiprocessor operation between the two CPU cores.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C7600_SIP200_MP-3

Error Message    %C7600_SIP200_MP-3-INIT_FAILURE: Second CPU initialization failed 

Explanation    The line-card CPU unit has two CPU cores in it. The second CPU core is not initialized successfully, so the line card is operating with one CPU core only. You may also see a SYS-2-MALLOCFAIL warning message.

Recommended Action    If this message appears when a line card boots up, reload the line card by entering the hw-module module slot reset command. Also, check the amount of memory on the line card by entering the show controller cwan command.

C7600_SIP200_MP-4

Error Message    %C7600_SIP200_MP-4-PAUSE: Non-master CPU is suspended for too long, 
from [hex]([int]) to [hex] for [int] CPU cycles. [chars] 

Explanation    The line-card CPU contains two CPU cores, one of which is the master CPU. The master CPU caused the second non-master CPU to be suspended for too long a time. This condition could cause the non-master CPU to drop packets. This warning indicates a transient software problem, and the line card should continue to operate normally.

Recommended Action    If the problem recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SIP200_MP-4-TIMEOUT: Master CPU request timed out [chars] 

Explanation    The line-card CPU contains two CPU cores, one of which is the master CPU. The non-master CPU is not responding in time to the request from the master CPU. This warning indicates a transient software problem. The line card should continue to operate normally.

Recommended Action    If the problem recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C7600_SIP200_SPIRX Messages

This section contains SIP 200 SPI4.2 bus ingress interface (C7600_SIP200_SPIRX) messages.

C7600_SIP200_SPIRX-3

Error Message    %C7600_SIP200_SPIRX-3-INITFAIL: Failed to configure the ingress SPI4.2 
device. Error = [hex] 

Explanation    The system cannot program or configure the ingress SPI4.2 device on the line card. This condition indicates an internal hardware error.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPIRX-3-SPA_INTERRUPT: SPA [int] - [chars], SPA Int 
status = [hex] 

Explanation    A SPA interrupt from the ingress SPI4.2 device has occurred.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPIRX-3-SPI4_LINKERROR: SPA Bay [int], [int] SPI4 Link 
Failures 

Explanation    Link errors from the ingress SPI4.2 device have occurred.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPIRX-3-SRAM_ERROR_DATA: SRAM[dec] Address = [hex][hex] 
Data = [hex][hex][hex]_[hex][hex][hex]_[hex][hex][hex]_[hex][hex] [hex] 

Explanation    An SRAM address and data dump has occurred.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPIRX-3-SRAM_INTERRUPT: [chars], Sram Int status = [hex] 

Explanation    An SRAM interrupt has occurred from the ingress SPI4.2 device.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPIRX-3-STATUS_INTERRUPT: [chars], Global Int status = 
[hex] 

Explanation    A status interrupt has occurred from the ingress SPI4.2 device.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

C7600_SIP200_SPITX Messages

This section contains SIP 200 SPI4.2 bus egress interface (C7600_SIP200_SPIRX) messages.

C7600_SIP200_SPITX-3

Error Message    %C7600_SIP200_SPITX-3-BADDESC: descriptor [hex], tag [hex], global 
channel [int] 

Explanation    The egress SPI4.2 device on the line card returns a descriptor entry that is corrupted.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-BADPAK: corrupted packet to [chars] 

Explanation    The egress SPI4.2 device on the line card is handling a packet that is corrupted. This condition indicates that an internal software error has occurred. The corrupted packet has been dropped.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-CHANNEL_ENABLE_FAIL: SPI4 Channel [int] for Bay 
[int], [chars] Failed 

Explanation    The specified SPI4 channel could not be enabled or disabled.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-DESCR_ERR_SPA0: SPAstatus=[hex], 
syndrome=[hex], RdRspOvf=[int], RdRspTo=[int], OvfVal=[int], OvfCh=[int], 
OvfDescHi=[hex], OvfDescLo=[hex], DisChk=[int], SeqErrVal=[int], SeqErrCh=[int] 

Explanation    The egress SPI4.2 device on the line card detected a sequence or FIFO overflow error while processing a TX descriptor. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-DESCR_ERR_SPA1: SPAstatus=[hex], 
syndrome=[hex], RdRspOvf=[int], RdRspTo=[int], OvfVal=[int], OvfCh=[int], 
OvfDescHi=[hex], OvfDescLo=[hex], DisChk=[int], SeqErrVal=[int], SeqErrCh=[int] 

Explanation    The egress SPI4.2 device on the line card detected a sequence or FIFO overflow error while processing a TX descriptor. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-DESCR_ERR_SPA2: SPAstatus=[hex], 
syndrome=[hex], RdRspOvf=[int], RdRspTo=[int], OvfVal=[int], OvfCh=[int], 
OvfDescHi=[hex], OvfDescLo=[hex], DisChk=[int], SeqErrVal=[int], SeqErrCh=[int] 

Explanation    The egress SPI4.2 device on the line card detected a sequence or FIFO overflow error while processing a TX descriptor. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-DESCR_ERR_SPA3: SPAstatus=[hex], 
syndrome=[hex], RdRspOvf=[int], RdRspTo=[int], OvfVal=[int], OvfCh=[int], 
OvfDescHi=[hex], OvfDescLo=[hex], DisChk=[int], SeqErrVal=[int], SeqErrCh=[int] 

Explanation    The egress SPI4.2 device on the line card detected a sequence or FIFO overflow error while processing a TX descriptor. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-DMA_SQERR: Syndrome=[hex], SPA=[int], Ch=[int], 
RdSz=[int], RdOff=[int][chars] 

Explanation    The egress SPI4.2 device on the line card detected a sequence error while processing a DMA operation. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFC_ERR_SPA0: SPAstatus=[hex][chars] 

Explanation    The egress data path device on the line card detected an error condition with the extended flow control bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFC_ERR_SPA1: SPAstatus=[hex][chars] 

Explanation    The egress data path device on the line card detected an error condition with the extended flow control bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFC_ERR_SPA2: SPAstatus=[hex][chars] 

Explanation    The egress data path device on the line card detected an error condition with the extended flow control bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFC_ERR_SPA3: SPAstatus=[hex][chars] 

Explanation    The egress data path device on the line card detected an error condition with the extended flow control bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFCEVNT_ERR: [chars] 

Explanation    The egress data path device on the line card detected an error while processing internal extended flow-control events. This condition could cause a reduced packet rate.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFC_QUEUE_STUCK: [chars] 

Explanation    The egress data path device on the line card detected an error condition with the extended flow control bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFCSTAT_FAIL_SPA0: [chars] 

Explanation    The egress SPI4.2 device on the line card detected an EFC status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFCSTAT_FAIL_SPA1: [chars] 

Explanation    The egress SPI4.2 device on the line card detected an EFC status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFCSTAT_FAIL_SPA2: [chars] 

Explanation    The egress SPI4.2 device on the line card detected an EFC status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-EFCSTAT_FAIL_SPA3: [chars] 

Explanation    The egress SPI4.2 device on the line card detected an EFC status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-FCSTAT_FAIL_SPA0: [chars] 

Explanation    The egress SPI4.2 device on the line card detected a SPI4.2 status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-FCSTAT_FAIL_SPA1: [chars] 

Explanation    The egress SPI4.2 device on the line card detected a SPI4.2 status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-FCSTAT_FAIL_SPA2: [chars] 

Explanation    The egress SPI4.2 device on the line card detected a SPI4.2 status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-FCSTAT_FAIL_SPA3: [chars] 

Explanation    The egress SPI4.2 device on the line card detected a SPI4.2 status clock or synchronization failure. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-INITFAIL: Failed to configure the egress SPI4.2 
device. Error = [hex] 

Explanation    The egress SPI4.2 device on the line card could not be programmed or configured. This indicates an internal hardware error.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-INT_PERR_SPA0: IntMemPerr=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an internal memory parity error. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-INT_PERR_SPA1: IntMemPerr=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an internal memory parity error. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-INT_PERR_SPA2: IntMemPerr=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an internal memory parity error. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-INT_PERR_SPA3: IntMemPerr=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an internal memory parity error. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-MISMATCH: Descriptor ring mismatch: expects 
[int] got [int] 

Explanation    The egress SPI4.2 device on the line card returned a descriptor entry that did not match what the line card CPU expected. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-OVERRUN_DROP: SPI4 overrun drops packet for SPA 
[int], queue [int], count [int] 

Explanation    While the egress SPI4.2 device on the line card sends an packet on the extended flow controlled channel, it overruns the SPI4 channel but cannot queue it to the internal hold queue. This indicates an internal software error.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-SPI4_ERR_SPA0: SPAstatus=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an error condition with the SPI4.2 bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-SPI4_ERR_SPA1: SPAstatus=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an error condition with the SPI4.2 bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-SPI4_ERR_SPA2: SPAstatus=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an error condition with the SPI4.2 bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-SPI4_ERR_SPA3: SPAstatus=[hex][chars] 

Explanation    The egress SPI4.2 device on the line card detected an error condition with the SPI4.2 bus interface. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

Error Message    %C7600_SIP200_SPITX-3-SRAM_ECCERR: EccSynd=[hex], Err1bit=[int], 
ErrMbit=[int], SecHalf=[int], SPA=[int], Ch=[int], Addr=[hex], DataHi=[hex], 
DataLo=[hex], DataEcc=[hex] 

Explanation    The egress SPI4.2 device on the line card detected a parity error in the egress packet memory. This condition could cause packets to drop.

Recommended Action    If this problem recurs, search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ under Product cat6000. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create or contact your Cisco technical support representative and provide the representative with the output of the show tech-support command for the line card and the show platform hardware spi4 spa-id efc channel [channel-id] command for the SPA.

C7600_SSC400 Messages

This section contains Services SPA Carrier Card (C7600_SSC400) messages.

C7600_SSC400-3

Error Message    %C7600_SSC400-3-DCM_FAIL: [chars] FPGA module DCM Lock Failure, 
status:[hex] 

Explanation    One or more of the Digital Clock Managers (DCM) for the data path field-programmable gate arrays (FPGAs) failed to lock. This indicates a hardware failure.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %C7600_SSC400-3-DP_COUNTERS: Failed to create DP counter process. 

Explanation    The system was unable to launch a process on bootup to monitor the counters of the data path field-programmable gate arrays (FPGAs).

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %C7600_SSC400-3-DP_ERROR: Bus Error initializing [chars] FPGA, addr: 
[hex]. 

Explanation    This field-programmable gate array (FPGA) could not be initialized due to a bus error. This condition indicates a hardware failure, possibly due to a failed field-programmable device (FPD) upgrade.

Recommended Action    Enter the show hw-module slot fpd command. If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %C7600_SSC400-3-DP_PROGRAMMING: [chars] FPGA failed to program. 

Explanation    This field-programmable gate array (FPGA) failed to program. This condition indicates a hardware failure, possibly due to a failed field-programmable device (FPD) upgrade.

Recommended Action    Enter show hw-module slot fpd.If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %C7600_SSC400-3-DPRX_ERR: [chars]. 

Explanation    An error occurred while receiving data from the SPA, possibly due to data corruption.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %C7600_SSC400-3-DPTX_ERR: [chars]. 

Explanation    An error occurred while sending data to the SPA, possibly due to data corruption.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %C7600_SSC400-3-DPTX_QDR: Error clearing QDR queue [dec]. 

Explanation    A quad data rate (QDR) queue did not flush completely.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %C7600_SSC400-3-SINGLE_SPA_MODE: Module will use only bay [dec]. Bay 
[dec] is shut. 

Explanation    The 7600-SSC-400 is in single-SPA mode.

Recommended Action    This message is informational only. No action is required.

Error Message    %C7600_SSC400-3-SSC_BAY_SHUT: Bay [dec] is shutdown because 
7600-SSC-400 is in single-spa-mode 

Explanation    The specified bay is shut down. In single-SPA mode, only one bay is active.

Recommended Action    Refer to the IPsec SPA documentation for information about single-SPA mode.

Error Message    %C7600_SSC400-3-SW_ERROR: NULL 

Explanation    A software error occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

C7600_SSC400-7

Error Message    %C7600_SSC400-7-DP_DISABLE: [chars] FPGA is forced disabled. 

Explanation    This field-programmable gate array (FPGA) has been forced into a disabled state. This is a debugging feature.

Recommended Action    No action is required.

C7600_SSC600 Messages

This section contains Services SPA Carrier Card (C7600_SSC600) messages.

C7600_SSC600-3

Error Message    %C7600_SSC600-3-DCM_FAIL: [chars] FPGA module DCM Lock Failure, 
status:[hex] 

Explanation    One or more of the Digital Clock Managers (DCM) for the data path FPGAs failed to lock. This condition indicates a hardware failure.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SSC600-3-DP_COUNTERS: Failed to create DP counter process. 

Explanation    A process is initialized at bootup to monitor the counters of the data path FPGAs. There was an error in creating this process.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SSC600-3-DP_ERROR: Bus Error initializing [chars] FPGA, addr: 
[hex]. 

Explanation    This FPGA could not be initialized because of a bus error. This condition indicates a hardware failure, possibly due to a failed FPD upgrade.

Recommended Action    Enter the show hw-module slot fpd command to gather more information about the specific nature of the condition. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SSC600-3-DP_PROGRAMMING: [chars] FPGA failed to program.

Explanation    This FPGA failed to program. This condition indicates a hardware failure, possibly due to a failed FPD upgrade.

Recommended Action    Enter the show hw-module slot fpd command to gather more information about the specific nature of the condition. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SSC600-3-DPRX_ERR: [chars]. 

Explanation    There was an error receiving data from the SPA, possibly due to data corruption.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SSC600-3-DPTX_ERR: [chars]. 

Explanation    There was an error sending data to the SPA, possibly due to data corruption.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SSC600-3-DPTX_QDR: Error clearing QDR queue [dec]. 

Explanation    One of the QDR queues did not clear completely.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %C7600_SSC600-3-SINGLE_SPA_MODE: Module will use only bay [dec]. Bay 
[dec] is shut. 

Explanation    The 7600-SSC-400 is in single-SPA mode.

Recommended Action    This message is informational. No action is required.

Error Message    %C7600_SSC600-3-SSC_BAY_SHUT: Bay [dec] is shutdown because 
7600-SSC-400 is in single-spa-mode 

Explanation    Specified bay is shut down. In single-SPA mode, only one bay is active.

Recommended Action    Refer to IPSEC SPA documentation for information about single-SPA mode.

Error Message    %C7600_SSC600-3-SW_ERROR: NULL 

Explanation    This condition arises when there is a problem in internal software coding; it should not arise under normal operation.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

C7600_SSC600-7

Error Message    %C7600_SSC600-7-DP_DISABLE: [chars] FPGA is forced disabled. 

Explanation    This FPGA has been disabled. Forced disabling is a debugging feature.

Recommended Action    No action is required.

CAMP Messages

This section contains Cooperative Asymmetric Multiprocessing (CAMP) messages.

CAMP-3

Error Message    %CAMP-3-MP_INIT_FAILURE: Second CPU initialization failed 

Explanation    The module CPU unit has two CPU cores in it. The second CPU core did not initialize successfully, so the module is operating with only one CPU core.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CAPI Messages

This section contains card application program interface (CAPI) messages.

CAPI-2

Error Message    %CAPI-2-INVALID_SLOT_NUM: Invalid slot number [dec], Expected value is 
between [dec] and [dec] 

Explanation    The system detected an internal software inconsistency that might affect the operation of one or more modules.

Recommended Action    Use the hw-module command to reload or power cycle any modules that are not operating correctly. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CAPI-2-INVALID_SPA_BAYNUM: SPA subslot number [dec] is invalid for 
slot [dec] 

Explanation    The system detected an internal software inconsistency that might affect the operation of the SPA in the slot and subslot specified in the error message.

Recommended Action    If the configuration for the SPA in the slot and subslot specified in the error message has not been loaded from the startup-configuration, use the copy nvram:startup-config system:running-config command after the SPA carrier has loaded to apply the configuration. Note that the interfaces will be configured as shutdown; enter the no shutdown command to restart the affected interfaces. If the operation of the given SPA is affected in other ways, use the hw-module command to reload or power cycle the module. If this message recurs, copy the message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    %CAPI-2-NOT_ENOUGH_MEMORY_FOR_XL: Not enough memory ([dec]K) for 
Feature Card [chars] ([dec]), which has minimum memory requirement of [dec]K 

Explanation    The XL EARL daughter card requires a minimum amount of memory. If memory size is less than the minimum requirement, system operations might be affected.

Recommended Action    Upgrade the memory to reach the minimum size requirement.

CAPI-3

Error Message    %CAPI-3-INVALID_SUBMODULE: The submodule type for slot [dec] is 
invalid 

Explanation    The system detected an internal software inconsistency that might affect the operation of one of the submodules (for example, an inline power supply or SPA) in the specified slot.

Recommended Action    Use the hw-module command to reload or power cycle the modules in the slot specified in the error message. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CAPI_EC Messages

This section contains Card/EtherChannel limitation (CAPI_EC) messages.

CAPI_EC-4

Error Message    %CAPI_EC-4-GROUP_RATE_LIMITED: Adding interfaces of the same 
port-group ([dec]-[dec]) on [chars] to an etherchannel will not increase the 
channel throughput! 

Explanation    Because ports on the specified slot use oversubscription, the total throughput of the port channel is limited by the port group.

Recommended Action    If more throughput is required, either use ports from a line card that does not use oversubscription, or use ports from different line cards or port groupings on oversubscribed line cards. For example, if the line card has 48 ports in groups of 8, you can select ports 1, 9, 17, 25, 33, and 41 for the same port channel.

Error Message    %CAPI_EC-4-RATE_LIMITED: Adding [chars] interfaces to an etherchannel 
will limit channel throughput to 1 Gbps! 

Explanation    Because ports on the indicated card type use oversubscription, throughput of the port channel is limited.

Recommended Action    If more throughput is required, either use ports from a line card that does not use oversubscription, or use ports from different line cards or port groupings on oversubscribed line cards. For example, if the line card has 48 ports in groups of eight, you can select ports 1, 9, 17, 25, 33, and 41 for the same port channel.

Error Message    %CAPI_EC-4-SLOT_RATE_LIMITED: Adding interfaces on slot [dec] to an 
etherchannel will limit channel throughput to 1 Gbps! 

Explanation    Because ports on the indicated slot use oversubscription, the total throughput of the port channel is limited.

Recommended Action    If more throughput is required, either use ports from a line card that does not use oversubscription, or use ports from different line cards or port groupings on oversubscribed line cards. For example, if the line card has 48 ports in groups of eight, you can select ports 1, 9, 17, 25, 33, and 41 for the same port channel.

CARDMGR Messages

This section contains SIP 400 Card Manager (data plane) (CARDMGR) messages.

CARDMGR-2

Error Message    %CARDMGR-2-ESF_DEV_ERROR: An error has occurred on [chars]: [chars] 

Explanation    The Express Services Forwarding (ESF) encountered an error during normal operation. Steps must be taken to resolve the problem and allow traffic through the SIP 400 line card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CARDMGR-2-ESF_LOAD_FAIL: [chars] failed to load: [chars] 

Explanation    The ESF could not be loaded because one of the steps in the startup sequence failed. This ESF is now not operational, which stops the traffic through the SIP-400 line card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CARDMGR-2-SPABUS_ERROR: A [chars] FSM SPA bus error has occurred in 
subslot [dec] 

Explanation    An FSM SPA bus error occurred during normal operation.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CARDMGR-4

Error Message    %CARDMGR-4-ESF_DEV_RELOADED: The ESF microcode has automatically 
recovered from an internal inconsistency. 

Explanation    An ESF internal inconsistency was detected during normal operation. The ESF microcode was reloaded to resolve the inconsistency.

Recommended Action    No action is required unless this message appears multiple times. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CARDMGR-4-ESF_LOAD_WARN: [chars] microcode load: [chars]

Explanation    The ESF was loaded even though a potential problem exists.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CARDMGR-4-ESF_LOOPBACK_FAIL: ESF loopback packet test failed: tried 
[dec] sent [dec] received [dec] 

Explanation    The ESF loopback packets sent after a microcode reload experienced excessive packet loss. This condition is usually an indication that data traffic through this line card is impacted as well.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CARDMGR-5

Error Message    %CARDMGR-5-ESF_DEV_INFO: ESF internal inconsistency corrected on 
[chars]: [chars] 

Explanation    An ESF internal inconsistency was detected and corrected during normal operation.

Recommended Action    No action is required unless this message appears multiple times. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CARDMGR-5-ESF_UCODE_DONE: Microcode download complete for [chars], 
time elapsed [time-stamp] 

Explanation    The ESF microcode was successfully downloaded and started. The forwarding engine is now configured and operational. The time elapsed is measured from the ESF_UCODE_START message.

Recommended Action    This is a normal activity at Cisco IOS boot time or after a fatal ESF error occurs. No action is necessary.

Error Message    %CARDMGR-5-ESF_UCODE_START: Downloading microcode [chars] for [chars], 
version=[chars], [chars] 

Explanation    The platform code was starting to download a particular ESF microcode image.

Recommended Action    This is a normal activity at Cisco IOS boot time or after a fatal ESF error occurs. No action is necessary.

CBUS Messages

This section contains Cisco Bus Controller (CBUS) messages.

CBUS-3

Error Message    %CBUS-3-CCBCMDFAIL3: Controller [dec], cmd ([dec] [hex], [hex], [hex]) 
failed ([hex]) 

Explanation    A command sent from the system to an interface processor failed to complete successfully.

Recommended Action    The system recovered by generating an error code for the requester. No action is necessary.

CHARLOTTE Messages

This section contains Dual OC-3 PoS port adapter (CHARLOTTE) messages.

CHARLOTTE-1

Error Message    %CHARLOTTE-1-INITFAIL: Failed to initialize port [dec]. 

Explanation    The Dual OC-3 PoS port adapter failed to complete IDB initialization.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CHARLOTTE-1-PCIINITFAIL: PCI initialization failed. 

Explanation    The Dual OC-3 PoS port adapter failed to complete hardware initialization.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CHARLOTTE-3

Error Message    %CHARLOTTE-3-INVALIDPCI: Device reported [hex] 

Explanation    The Dual OC-3 PoS port adapter hardware failed. The PCI device has an invalid ID.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CHARLOTTE-3-UNSUPPORTED: [chars] 

Explanation    The Dual OC-3 PoS port adapter hardware is not supported on the specified platform.

Recommended Action    Upgrade your system so that it supports the Dual OC-3 PoS port adapter.

CHKPT Messages

This section contains checkpointing (CHKPT) messages.

CHKPT-3

Error Message    %CHKPT-3-ILLEGAL: ILLEGAL call to CF API on ([chars]) by ([chars]). 

Explanation    A severe software error occurred with the Checkpoint Facility (CF) application program interface (API).

Recommended Action    Verify that the system is running released software. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message    %CHKPT-3-IPCPORT: Unable to create IPC port on ([chars]). 

Explanation    A severe checkpoint error occurred. The system was unable to allocate the resources needed to create a communications port for the Interprocess Communications (IPC) channel needed to transmit messages.

Recommended Action    Verify that the system is running released software. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message    %CHKPT-3-IPCSESSION: Unable to open an IPC session for communicating 
with ([chars]). rc= [dec] 

Explanation    A severe checkpoint error occurred. The system was unable to establish an Interprocess Communications (IPC) session between interfaces, which is needed to transmit messages.

Recommended Action    Verify that the system is running released software. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message    %CHKPT-3-NOMEM: Unable allocate resource for CF on ([chars]). 

Explanation    A severe checkpoint error occurred. The system was unable to allocate the necessary resources (typically memory) on the indicated interface to create an Interprocess Communications (IPC) channel for transmitting messages.

Recommended Action    Verify that the system is running released software. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message    %CHKPT-3-RFREG: Unable to register checkpoint as client of RF. 

Explanation    A severe checkpoint error occurred. The system was unable to register with the redundancy facility (RF) so that it could begin the transmission of IPC messages between interfaces.

Recommended Action    Verify that the system is running released software. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.

Error Message    %CHKPT-3-UNKNOWNMSG: Unknown message received from peer on standby for 
client ([dec]). 

Explanation    A severe software error occurred with the Checkpoint Facility (CF) subsystem. This might indicate a Cisco IOS software mismatch between the active and standby interfaces.

Recommended Action    Verify that the system is running released software. If the problem persists, copy the error message exactly as it appears, and report it to your technical support representative.

CHKPT-4

Error Message    %CHKPT-4-DUPID: Duplicate checkpoint client ID ([dec]). 

Explanation    A checkpoint client is using a client ID that is already assigned to another client. This could be due to a synchronization delay, which typically will resolve itself.

Recommended Action    No action is required.

Error Message    %CHKPT-4-INVALID: Invalid checkpoint client ID ([dec]). 

Explanation    A checkpoint client is using an old or stale client ID. This could be due to a synchronization delay, which typically will resolve itself.

Recommended Action    No action is required.

CONST_DIAG Messages

This section contains Online Diagnostics (CONST_DIAG) messages.

CONST_DIAG-2

Error Message    %CONST_DIAG-2-HM_FAB_SWOVER: Fabric card switchover due to 
unrecoverable errors, Reason: Failed [chars] 

Explanation    The fabric module has switched over because of unrecoverable error. The failure is specified in the message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-2-HM_LC_CRSH: Module [dec] crashed due to unrecoverable 
errors, Reason: Failed [chars] 

Explanation    The system detected an unrecoverable error that caused the specified module to fail.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-2-HM_MOD_RESET: Resetting Module [dec] for software 
recovery, Reason: Failed [chars] 

Explanation    The system detected an unrecoverable error that caused the specified module to reset.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-2-HM_SUP_CRSH: Standby supervisor crashed due to 
unrecoverable errors, Reason: Failed [chars] 

Explanation    The system detected an unrecoverable error that caused the redundant supervisor engine to fail.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-2-HM_SUP_CRSH: Supervisor crashed due to unrecoverable 
errors, Reason: Failed [chars] 

Explanation    The system detected an unrecoverable error that caused the supervisor engine to fail.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-2-HM_SUP_SWOVER: Supervisor card switchover due to 
unrecoverable errors, Reason: Failed [chars] 

Explanation    The system detected an unrecoverable error that caused this supervisor engine switchover.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-2-HM_TEST_FAIL: Module [dec] [chars] consecutive failure 
count:[dec] 

Explanation    The system detected an unrecoverable error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-2-HM_TEST_WARNING: Sup switchover will occur after [dec] 
consecutive failures 

Explanation    The system detected an unrecoverable error. A supervisor engine switchover will occur after the specified number of consecutive failures.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CONST_DIAG-3

Error Message    %CONST_DIAG-3-BOOTUP_TEST_FAIL: [chars]: [chars] failed [chars] 

Recommended Action    The indicated test failed during bootup diagnostics.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-DIAG_FIB_TCAM_TEST: Fib Tcam test: Missed at address 
[hex], device #[dec], HRR = [hex], lookup value = [hex]-[hex] 

Explanation    The FIB TCAM device might not be functional because the test failed to get a response at the reported address and look-up value.

Recommended Action    Rerun the test with the NO RESET option after resetting the module. If the test fails again at the same address, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-DIAG_FW_TEST_CARD_DOWN: Failed to disable module [dec] 

Explanation    The module could not be powered down after firmware diagnostics failed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-DIAG_FW_TEST_CARD_RESET: Failed to reset module [dec] 

Explanation    The module could not be reset after firmware diagnostics failed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-DIAG_TEST_PORT_SKIP: Module [dec] [chars] skipped 
multiple ports due to high traffic (Traffic=[dec]%)

Explanation    Online diagnostics did not take place on multiple ports in the specified module because of high traffic volume.

Recommended Action    No action is required.

Error Message    %CONST_DIAG-3-DIAG_TEST_SKIP: Module [dec] [chars] skipped due to high 
traffic (Traffic=[dec]%)

Explanation    Online diagnostics were skipped on the specified module because of high traffic volume.

Recommended Action    No action is required.

Error Message    %CONST_DIAG-3-HM_ALL_PORT_ERR: All ports on module [dec] failed 
[chars]. 

Explanation    The data paths that correspond to all ports of the module have failed.

Recommended Action    Check your network configuration for spanning tree loops, excessive flooding, and other related conditions. Reset the line card to see if the problem resolves itself. If the conditions persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-HM_CHAN_ERR: All ports in channel [dec] on module [dec] 
failed [chars]. Disabled the channel. 

Explanation    The data path that corresponds to the channel has failed. All ports that are part of the channel are put into errdisable state.

Recommended Action    Check your network configuration for spanning tree loops, excessive flooding, and other related conditions. Reset the line card to see if the problem resolves itself. If the condition persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-HM_FCI_0_STUCK: Flow control stuck at 0 error on module 
[dec]! 

Explanation    The signal LDBUS_FCI_L0 is stuck on active-low. The line card is powered down.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-HM_PORT_ERR: Port [dec] on module [dec] failed [dec] 
consecutive times. Disabling the port. 

Explanation    The data path that corresponds to the port has failed. The port is put into errdisable state.

Recommended Action    Reset the line card to see if the problem resolves itself. If the condition persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CONST_DIAG-3-SUP_FAILURE: [chars] supervisor has [chars] online 
diagnostic failure [hex]: [chars] 

Explanation    The specified supervisor engine has experienced an online diagnostic failure.

Recommended Action    Depending on whether failure is minor, major, or critical, the supervisor engine will display a warning message during the boot process, or the supervisor engine will fail and go into ROM monitor mode.

CONST_DIAG-4

Error Message    %CONST_DIAG-4-DIAG_DETECT_FABRIC_CHAN_LOW_RATE: Module [dec] fabric 
channel [dec] [chars] is low ([hex] instead of [hex]). 

Explanation    The diagnostic test has detected a fabric low buffer rate for the fabric channel.

Recommended Action    Flow control is occurring in the system. Analyze the system traffic, and remove the traffic source that causes flow control. Enter the show fabric utilization command to determine the overall traffic pattern.

Error Message    %CONST_DIAG-4-DIAG_SUGGEST_ACTION_DUE_TO_FABRIC_CHAN_FLOW_CONTROL: 
Flow control is occurring in the system. Analyze the system traffic and remove the 
traffic source that causes flow control. 

Explanation    This message appears when a diagnostic test has detected a low buffer rate in the switch fabric.

Recommended Action    Flow control is occurring in the system. Analyze the system traffic and remove the traffic source that causes flow control. Enter the show fabric utilization command to check the overall traffic pattern.

Error Message    %CONST_DIAG-4-DIAG_SUGGEST_ACTION_DUE_TO_FABRIC_CHAN_LOW_RATE: Flow 
control is occurring in the system. Analyze the system traffic and remove the 
traffic source that causes flow control. 

Explanation    The diagnostic test has detected a low buffer rate for the fabric channel. Flow control is occurring in the system.

Recommended Action    Analyze the system traffic and remove the traffic source that is causing flow control. Enter the show fabric utilization command to determine the overall traffic pattern.

Error Message    %CONST_DIAG-4-HM_TEST_WARNING: [chars] will occur after [dec] 
consecutive failures 

Explanation    The system has detected an unrecoverable error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CONST_DIAG-6

Error Message    %CONST_DIAG-6-DIAG_ONDEMAND_NOT_SUPPORTED: [chars] is not supported 
on-demand for module [dec]

Explanation    The specified on-demand online diagnostics are not supported on the specified module.

Recommended Action    This message is informational. No action is required.

Error Message    %CONST_DIAG-6-DIAG_RERUN_RESET: Resetting Module [dec] to re-run 
[chars] diagnostic 

Explanation    The system is resetting the module to rerun diagnostics.

Recommended Action    This message is informational. The system is working properly.

Error Message    %CONST_DIAG-6-HM_MESSAGE: High traffic/CPU util seen on Module [dec] 
[SP=[dec]%,RP=[dec]%,Traffic=[dec]%] 

Explanation    The system bypassed the health-monitoring test on the specified module because of high utilization of system resources.

Recommended Action    This message is informational. No action is required.

Error Message    %CONST_DIAG-6-HM_TEST_INFO: CPU util(5sec): SP=[dec]% RP=[dec]% 
Traffic=[dec]% netint_thr_active[[dec]], Tx_Rate[[dec]], Rx_Rate[[dec]] 

Explanation    This message provides system resource information during an event.

Recommended Action    This message is informational. No action is required.

Error Message    %CONST_DIAG-6-HM_TEST_SP_INFO: [chars][[dec]]: 
last_busy_percent[[dec]%], Tx_Rate[[dec]], Rx_Rate[[dec]]

Explanation    This message displays system resource information during the event

Recommended Action    This message is informational only. No action is required.

Error Message    %CONST_DIAG-6-HM_TEST_RECOVERED: Module [dec] [chars] recovered after 
[dec] consecutive failure(s) 

Explanation    The health-monitoring test recovered from transient failure on the specified module.

Recommended Action    This message is informational. No action is required.

CONST_V6 Messages

This section contains IP version 6 (CONST_V6) messages.

CONST_V6-5

Error Message    %CONST_V6-5-FIB_EXCEP_OFF: Protocol IPv6 recovered from FIB exception 

Explanation    The IPv6 CEF table successfully reloaded to the hardware FIB TCAM. All IPv6 packets will be switched by the hardware.

Recommended Action    No action is required.

Error Message    %CONST_V6-5-FIB_EXCEP_ON: Failed to insert an IPv6 prefix in hardware 
FIB TCAM 

Explanation    The switch failed to insert an IPv6 entry into the hardware FIB TCAM because the total number of software forwarding entries exceeded the hardware FIB TCAM limit. Some IPv6 packets might be switched by the software.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CPU_MONITOR Messages

This section contains CPU monitor (CPU_MONITOR) messages.

CPU_MONITOR-2

Error Message    %CPU_MONITOR-2-NOT_RUNNING: CPU_MONITOR messages have not been sent 
for [dec] seconds [[chars] [dec]%/[dec]% ([time-stamp] [dec]%/[dec]%)] [[chars] 
[time-stamp]] [[chars] [time-stamp]] [[chars] [time-stamp]]

Explanation    CPU monitor messages have not been heard for a significant amount of time. A timeout is likely to occur soon, which will reset the system.

Recommended Action    No action is required.

Error Message    %CPU_MONITOR-2-NOT_RUNNING_TB: CPU_MONITOR traceback: [hex] [hex] 
[hex] [hex] [hex] [hex] [hex] [hex] 

Explanation    This message provides additional debugging information for the NOT_RUNNING message. The message displays the traceback of the interrupted functions.

Recommended Action    No action is required.

CPU_MONITOR-3

Error Message    %CPU_MONITOR-3-PEER_EXCEPTION: CPU_MONITOR peer has failed due to 
exception , resetting [[dec]/[dec]] 

Explanation    The CPU monitor messages failed on the peer processor. The system is no longer operational.

Recommended Action    No action is required.

CSG Messages

This section contains Content Services Gateway (CSG) messages.

CSG-6

Error Message    %CSG-6-LIRELOADOK: CSG LI reload on module [dec] successful

Explanation    The CSG LI configuration was reloaded because of the power cycling of a CSG module.

Recommended Action    No action is required.

CWAN_ATM Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN ATM port (CWAN_ATM) messages.

CWAN_ATM-3

Error Message    %CWAN_ATM-3-LOWMEM: Could not allocate memory for RFC 1483 packet 
cloning.

Explanation    Memory is running low.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

Error Message    %CWAN_ATM-3-PORT_ERR: Invalid PORT [dec] 

Explanation    The specified port does not exist.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_ATM-3-VCD_ERR: Invalid PortVCD [hex] 

Explanation    The specified port VCD does not exist.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_ATM-3-VC_ERR: Invalid VC [hex] 

Explanation    The specified VC does not exist on the port.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_ATM-3-VC_OR_PORT_ERR: Invalid VCD [hex] or Port: [dec] 

Explanation    Either the port or the VCD is invalid.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_ATM-5

Error Message    %CWAN_ATM-5-UNKNOWN_VCD: Unknown port vcd [hex] in egress packet 

Explanation    An unknown VCD has been received in the egress path of the module. This condition is most likely a transient condition, and it is usually caused by VCs that are being disassembled and reassembled while traffic is being passed.

Recommended Action    No action is required.

CWAN_CHOC_DSX Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN CHOC DSX LC Common (CWAN_CHOC_DSX) messages.

CWAN_CHOC_DSX-3

Error Message    %CWAN_CHOC_DSX-3-NODESTROYSUBBLOCK: The [chars] subblock named [chars] 
was not removed 

Explanation    A software error occurred. This message displays when interface description block (IDB) subblocks cannot be removed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_HA Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN module high availability (CWAN_HA) messages.

CWAN_HA-2

Error Message    %CWAN_HA-2-CCB_PLAYBACK_ERROR: CCB playback failed for slot [dec]. 

Explanation    The high availability component for WAN modules failed to synchronize new state information for the specified slot.

Recommended Action    Reload the redundant supervisor engine to force a fresh bulk synchronization. If this error recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs. Examine both the active supervisor engine and the redundant supervisor engine for messages.

Error Message    %CWAN_HA-2-CCB_RECORD_ERROR: CCB record failed for slot [dec]. 

Explanation    The high availability component for WAN modules failed to record new state information for the specified slot. The system is falling back to RPR mode for high availability.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs. Examine both the active supervisor engine and the redundant supervisor engine for messages.

Error Message    %CWAN_HA-2-IFCFG_PLAYBACK_ERROR: Interface Configuration command 
[int] playback failed for slot [int]/[int]. 

Explanation    The high availability component for WAN modules failed to synchronize new state information for the specified slot. The redundant system is no longer synchronized with the active system. The redundant supervisor engine was reloaded shortly after this error was encountered.

Recommended Action    If this error recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_HA-2-IFCFG_RECORD_ERROR: Interface Configuration command [int] 
record failed for slot [int]/[int]. 

Explanation    The high availability component for WAN modules failed to record some new state information for the specified slot. The system is falling back to RPR mode for high availability.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_HA-3

Error Message    %CWAN_HA-3-CCB_INIT_ERROR: Failed to initialize CCB list for slot 
[dec]. 

Explanation    The high availability component for WAN modules failed to properly initialize state information for the specified slot. The system is falling back to RPR mode for high availability.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs. Examine both the active supervisor engine and the redundant supervisor engine for messages.

Error Message    %CWAN_HA-3-IFCFG_INIT_ERROR: Failed to initialize Interface 
Configuration list for slot [int]/[int]. 

Explanation    The high availability component for WAN modules failed to properly initialize state information for the specified slot. The system is falling back to RPR mode for high availability.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs. Examine both the active supervisor engine and the redundant supervisor engine for messages.

Error Message    %CWAN_HA-3-IFCFG_NO_UNIQUE_KEY: No unique-key generator registered for 
interface configuration command [int]. 

Explanation    The high availability component for WAN modules is unable to properly synchronize state information for the current configuration. The system is falling back to RPR mode for high availability.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs. Examine both the active supervisor engine and the redundant supervisor engine for messages.

CWAN_HA-4

Error Message    %CWAN_HA-4-NOSRPBULKSYNC: Failed to [chars] srp bulk data (slot=[dec], 
intf=[dec], type=[dec]), ret code [dec]

Explanation    The synchronization of RP bulk data and SRP bulk data failed from the active supervisor engine to the redundant supervisor engine.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_HA-4-NOSRPSYNC: Failed to sync srp packet 
(slot=[dec],intf=[dec]) to standby, HA_SYNC_STATUS=[dec]

Explanation    The RP dynamic synchronization of SRP packets failed from the active supervisor engine to the redundant supervisor engine.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_HA-4-SRPSYNC: Slot [dec]: [chars] 

Explanation    The specified error occurred while synchronizing the SRP states from the active supervisor engine RP to the redundant supervisor engine RP.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWANLC Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN module (CWANLC) messages.

CWANLC-3

Error Message    %CWANLC-3-FPD_INCOMPATIBLE: FPD ID=[int] image in this FPD package is 
for revision [int].x boards. It is incompatible with current board revision of 
[int].[int] 

Explanation    This FPD package does not contain images that are compatible with the current line card revision.

Recommended Action    Perform the FPD upgrade operation with a newer version of an FPD image package that is compatible with the Cisco IOS software that is operating on the switch. Consult with the FPD image package section of the Cisco IOS software release note to confirm that your line card revision is supported for a particular release.

Error Message    %CWANLC-3-CWANLC_EARL_VERSION_NOTICE: CWAN receives mismatch Earl 
version notification. New Earl[int] vs Earl[int] 

Explanation    The RP determined through an SCP find operation that the version of the EARL switching engine on the module has changed. This message occurs during a switchover operation. The version of the EARL switching engine is specified in the message text.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWANLC-3-FATAL: [chars] 

Explanation    The OSM encountered a fatal error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWANLC-3-TVPN_NOMEM: Failed to start vpn, not enough memory 

Explanation    The OSM could not start VPN due to insufficient memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWANLC_ATM Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN ATM module (CWANLC_ATM) messages.

CWANLC_ATM-3

Error Message    %CWANLC_ATM-3-VCCLOSEFAIL: [chars]: Failed to remove VC [dec]/[dec] 
cause [int] 

Explanation    An attempt to remove a virtual circuit on the module failed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_QINQ Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN QinQ (CWAN_QINQ) messages.

CWAN_QINQ-3

Error Message    %CWAN_QINQ-3-CWAN_QINQ_TRUNK_DATAINCONSISTENCY: QinQ data integrity 
check failed for bridge-vlan [int] dot1q [int] using trunk encapsulation dot1q 
[int], existing record shows mapping with encapsulation dot1q [int]. 

Explanation    A data integrity error related to QinQ was detected while a trunk was being configured for the bridge VLAN that is indicated in the message text. The error will be ignored, and the QinQ update will proceed normally.

Recommended Action    Enter the show cwan qinq command on the module. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_RP Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN route processor driver (CWAN_RP) messages.

CWAN_RP-0

Error Message    %CWAN_RP-0-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-0-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_RP-1

Error Message    %CWAN_RP-1-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-1-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_RP-1-OVERRIDE_MAC_INVALID: [chars] has invalid 
override-mac-address.

Explanation    The user issued an override MAC address that does not match the MAC address of the MSFC. This condition can occur if the configuration was moved to new hardware or the MAC address command was used on another interface. While the system automatically corrects this condition, the configuration needs to be adjusted.

Recommended Action    Modify the override MAC address command in the configuration.

CWAN_RP-2

Error Message    %CWAN_RP-2-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-2-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_RP-3

Error Message    %CWAN_RP-3-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-3-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_RP-3-MODULE_TYPE: cannot find FCI for module type [int] in slot 
[int] 

Explanation    An internal software error occurred while the system was detecting the module type in the specified slot. The module operation will be affected.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_RP-3-PROCMSG: Process msg send failed for process[dec] 

Explanation    An attempt to send a process message failed for the specified process.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_RP-3-UPGRADE_ERROR: Slot [int]: The ROMMON upgrade failed to 
complete. 

Explanation    An error occurred during the upgrade process.

Recommended Action    If the module reloads successfully, examine the file and try the upgrade process. If this message recurs, contact your Cisco technical support representative.

Error Message    %CWAN_RP-3-WAN_BRIDGING_CONFIG_EXCEEDED: The number of 
VPLS/EoMPLS/Bridging/QinQ VCs exceeded the maximum supported by the platform 

Explanation    The user attempted to configure more VPLS, EoMPLS, and bridging VCs than the number that is supported by the platform.

Recommended Action    Review the configuration guidelines for the features that are being configured, and reduce the number of VPLS, EoMPLS, and bridging VCs to the number that is supported by the platform.

CWAN_RP-4

Error Message    %CWAN_RP-4-CONFIG_MISMATCH: Irreconcilable Configuration difference 
between Active & Standby Supervisors due to OIR/Config Event -> Reloading Standby 
Supervisor to synchronize the configuration.

Explanation    An unexpected configuration difference exists between the active and standby supervisor engines.

Recommended Action    This condition is expected behavior. No action is required.

Error Message    %CWAN_RP-4-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-4-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_RP-4-MODULE_CONFIG_MISSING: configuration missing for slot [int] 

Explanation    Some information is missing regarding the configuration of the module in the specified slot. Any startup configuration for the interfaces will not be applied. If the module in the specified slot is a FlexWAN, details about the port adapters in the FlexWAN are missing from the configuration information. This information is missing from the SLOTCACHE ROMMON variable.

Recommended Action    If the module in the slot specified in the error message has not previously been inserted, it has no previous configuration; therefore, no action is required. If the configuration for the specified slot in the startup configuration is suitable for the module in that slot, after the module has loaded, manually apply the configuration by using one of the following two methods. The second method requires a system reload.

–Enter the copy nvram:startup-config system:running-config command to reapply your saved configuration, then enter the no shutdown command on all interfaces whose configuration was rejected, and then enter the copy system:running-config nvram:startup-config command to save your configuration and the WAN module slot configuration.

–Enter the copy command to copy your startup configuration to a temporary location (for example, copy nvram:startup-config bootflash:tmp-config), then enter the copy system:running-config nvram:startup-config command to update the WAN module slot configuration, then enter the copy command to restore the temporary copy of the startup-config (for example, copy bootflash:tmp-config nvram:startup-config), and then enter the reload command to reload the system.

After using the second method, you may want to use the delete command to remove the temporary copy of the startup-config. To prevent this condition from recurring, ensure that the SLOTCACHE variable is updated whenever modules that require it (FlexWANs, but not OSMs) are moved between slots in the chassis. The SLOTCACHE variable is updated when the running-config is written to the startup-config using the copy system:running-config nvram:startup-config command (or the deprecated write memory equivalent). The two methods of restoring the configuration for the module shown above ensure that the SLOTCACHE variable is updated.

CWAN_RP-5

Error Message    %CWAN_RP-5-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-5-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_RP-6

Error Message    %CWAN_RP-6-ADF_FILE: Slot [int]: Using VPN-SM Upgrade File: "[chars]" 

Explanation    The system is booting the specified upgrade image for VPN Services Module.

Recommended Action    No action is required.

Error Message    %CWAN_RP-6-AUX_FILE: Slot [int]: Found VPN-SM Firmware in File: 
"[chars]" 

Explanation    The file specified in the message was found and will be loaded instead of the bundled image by the VPN Services Module.

Recommended Action    No action is required.

Error Message    %CWAN_RP-6-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-6-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWAN_RP-6-OVERRIDE: Slot [int]: ...Overriding Intrinsic VPN-SM 
Firmware. 

Explanation    The specified image will be used instead of the bundled image.

Recommended Action    No action is required.

Error Message    %CWAN_RP-6-UPGRADE_COMPLETE: Slot [int]: ROMMON upgrade complete. 
Reset the card for the changes to take effect. 

Explanation    The ROMMON upgrade has completed successfully. The module must be reloaded for the changes to take effect.

Recommended Action    No action is required.

CWAN_RP-7

Error Message    %CWAN_RP-7-LCLOG_MSG : slot [dec]/[dec]: [chars]

Explanation    An error has occurred on a module. The slot and CPU number are indicated after the CWAN_RP-7-LCLOG_MSG text. The error message that appears after the slot number is the original message from the module.

Recommended Action    Follow any instructions provided in the error message text. If no instructions are provided, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWAN_SP Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router WAN switch processor (CWAN_SP) messages.

CWAN_SP-3

Error Message    %CWAN_SP-3-INIT_FAIL: Failed to allocate [dec] bytes memory needed for 
CWAN SP module initialization 

Explanation    A memory allocation failure has occurred during initialization of WAN SP module.

Recommended Action    Upgrade to a higher memory size on the switch processor (SP).

CWAN_SP-4

Error Message    %CWAN_SP-4-UNKNOWN_PW: Unknown CWAN pseudo wire on vlan [dec], port 
[dec]/[dec] 

Explanation    An unknown WAN pseudowire is being used.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWPA Messages

This section contains Catalyst 6500 series switch and Cisco 7600 series router port adapter module (CWPA) messages.

CWPA-2

Error Message    %CWPA-2-BAD_HWVERS: Unable to determine board hardware version 

Explanation    The module software cannot read the module hardware version. This condition indicates a hardware error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWPA-2-PAOIR: Port adapter OIR not supported, reloading 

Explanation    An OIR operation occurred on the port adapters of the specified module, but OIR is not supported on the port adapter. This error has caused the module to fail and reload.

Recommended Action    Do not attempt OIR on the port adapters of the specified module.

Error Message    %CWPA-2-PA_VOLFAIL: Port adapter [dec]V failed, Reloading flexwan 

Explanation    The module encountered an error involving power delivery to the module. Probable causes for this error are an environmental condition, an overtemperature condition, or inconsistent voltage to the module.

Recommended Action    Verify that the input voltage and the temperature of the module are within acceptable ranges.

Error Message    %CWPA-2-WHICH_INT: Unexpected [chars] interrupt, INT status = [hex] 

Explanation    The module specified in the error message has encountered an unexpected interrupt.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWPA-3

Error Message    %CWPA-3-DIAGFAIL: Failed to handle diag [chars] [dec] 

Explanation    The module failed to execute a diagnostics command.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWPA-3-PROCCREATEFAIL: Failed to create [chars] process 

Explanation    A module failed to create a process that is necessary for proper functioning of the module.

Recommended Action    Copy the error message as it appears, and report it to your technical support representative. If a statistics export process was not created, check the I/O rate and the bytes that are getting incremented in the show interface command output for the non-channelized interfaces on the FlexWAN/Enhanced FlexWAN modules. You can also get the statistics from the show interface acc command output or the show interface stats command output.

CWRPSPA Messages

This section contains messages for Shared Port Adapters on the Catalyst 6500 Series Switch and Cisco 7600 Series Router WAN Route Processor (CWRPSPA).

CWRPSPA-3

Error Message    %CWRPSPA-3-MAX_SPA: Power to IPSEC-SPA-2G in [chars] is denied because 
it has exceeded the number allowed([dec]) 

Explanation    The number of IPSEC-SPA-2G port adapters in a chassis is limited. This message displays when the number of IPSEC-SPA-2G port adapters in the chassis has exceeded the limit.

Recommended Action    Use only the number of supported IPSEC-SPA-2G port adapters.

CWRPSPA-4

Error Message    %CWRPSPA-4-SPA_CMD_NO_RESP: [chars]: No response for interface 
configuration command [int] 

Explanation    A timeout occurred while the RP was waiting for a response from the line card. This condition may occur when the line card CPU is too busy to respond to the configuration command.

Recommended Action    Retry the configuration command.

CWRPSPA-6

Error Message    %CWRPSPA-6-CARDRELOAD: Module [int] reload due to SPA insert in 
[int]/[int]. 

Explanation    When inserting a SPA on the specified module, the module resets.

Recommended Action    This message is informational. No action is required.

CWSLC Messages

This section contains WAN SiByte Module (CWSLC) messages.

CWSLC-3

Error Message    %CWSLC-3-DIAGFAIL: Failed to handle diag [chars] [dec] 

Explanation    The module failed to execute a diagnostics command.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWSLC-3-DIAGWARNING: Backplane DIP switches settings incorrect 

Explanation    The backplane DIP switches need to be set properly.

Recommended Action    Refer to the 7600 SIP and SPA Hardware Installation Guide for information about how DIP switches must be set.

Error Message    %CWSLC-3-IPCALLOCFAIL: Failed to allocate IPC buffer [chars] 

Explanation    An Enhanced FlexWAN module failed to allocate a buffer for communication with the route processor (MSFC).

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWSLC-3-IPCSENDFAIL: Failed to send IPC message [chars] 

Explanation    An Enhanced FlexWAN module failed to send a message to the route processor (MSFC).

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC Messages

This section contains WAN Optical Services Module (CWTLC) messages.

CWTLC-0

Error Message    %CWTLC-0-FATAL_EXCEPTION: [chars] 

Explanation    The OSM encountered a fatal exception.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC-2

Error Message    %CWTLC-2-FATAL_ATM: [chars] 

Explanation    The OSM encountered a fatal line management interrupt. This error is not recoverable and will cause the system to fail.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-2-PCITIMEOUT: Fatal Local I-O Bus [dec] Timeout Addr = [hex] 

Explanation    The OSM encountered a PCI timeout.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-2-PLIM_RX: [chars] 

Explanation    The OSM encountered an FPGA error that caused a sequence error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-2-SLAVEPCI: [chars] 

Explanation    The OSM encountered a PCI error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-2-TESTCRASH: [chars] 

Explanation    The user entered a command that caused the module to fail.

Recommended Action    No action is required.

CWTLC-3

Error Message    %CWTLC-3-ATMTXFIFO: [chars] 

Explanation    The OSM encountered an error with the FPGA that has caused the FIFO queue to exceed the maximum limit. This condition will cause the system to fail.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-EXCEPTION_ERR: [chars] 

Explanation    The OSM encountered an error exception.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-FR_INTLEVEL: unexpected interrupt level invocation of 
frame-relay handler:[chars] if_number([dec]) dlci([dec]) 

Explanation    Some feature code mistakenly invoked the module Frame Relay handler, which is designed to run at process level. This condition may lead to data corruption and a module failure.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-LTL_ERR: Inconsistent port selection [hex] assigment for 
PXF([dec]) Vlan([dec]) on PXF([int]) 

Explanation    The port selection information stored in the database is not valid.

Recommended Action    Shut down the interface VLAN and restart the interface VLAN.

Error Message    %CWTLC-3-MEDUSA_FATAL: OSM Medusa ASIC Fatal Error. ERROR CODE: 
[chars] 

Explanation    The OSM Medusa ASIC received the specified fatal error.

Recommended Action    No action is required if traffic recovers. If traffic does not recover, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-MEDUSAPXF: CWAN PXF Client [[dec]] Not Running 

Explanation    An ASIC device on the OSM has detected that the specified PXF client is not running.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-NOMEM: [chars] 

Explanation    The OSM could not obtain statistics due to depleted memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-NO_STATID: PXF([dec]): no stat_id is available for statistics 
collection 

Explanation    The OSM has used up all resources for statistics collection. No additional resources are available for further statistics collection.

Recommended Action    Reduce the number of features configured on the specified PXF. If conditions warrant, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-OLDIOFPGA: Upgrade your I/O FPGA 

Explanation    The OSM has an older release of the I/O FPGA software.

Recommended Action    Contact your Cisco technical support representative to upgrade the I/O FPGA software.

Error Message    %CWTLC-3-PLIM_TX: [chars] 

Explanation    The OSM encountered an FPGA error that caused a sequence error. The module will attempt to recover from the error.

Recommended Action    If the system recovers, no action is required. If the system does not recover, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-SECPAIRINT: Unexpected VA/Toaster interrupt from second pair 

Explanation    The OSM experienced an unexpected interrupt.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-TITANFATAL: Titan Fatal Error. Resetting ASIC. 

Explanation    The OSM Titan ASIC received a fatal error.

Recommended Action    No action is required if traffic recovers. If traffic does not recover, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-TMC_STATID_INCONSISTENCY: PXF([dec]):Inconsistent stats 
id([hex]) [int] packets dropped. 

Explanation    The WAN module received inconsistent statistics from the PXF. The PXF reported that a packet was dropped, but the PXF did not report the correct packet count.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-TMTRIE_ALLOC_FAILED: Failed to allocate toaster mtrie nodes. 

Explanation    The system encountered an error while it was attempting to allocate memory from a WAN OSM component.

Recommended Action    Reduce the number of routes associated with a VRF identifier or upgrade the WAN OSM to a higher version.

Error Message    %CWTLC-3-UNSUPPORTED_LABEL_RANGE: The maximum label range configured 
for this system exceeds
the [int] limit supported by the OSM module.

Explanation    The MPLS label range configured for this system is not supported. The maximum label range limit is specified in the message.

Recommended Action    Change the maximum MPLS label range by entering the mpls label range command.

Error Message    %CWTLC-3-VTMS: [chars] 

Explanation    The OSM could not schedule the wheel entry. The reason for the error is specified in the error message text.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-3-VTMSQ_NOTIDLE: Queue not idle when modifying Q([hex]) 

Explanation    The VTMS queue was in the process of being modified for a change in QoS configuration, but packets were still going through the queue. There is generally no traffic in the queue when the queue is being modified.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC-4

Error Message    %CWTLC-4-ASIC_RESET: Reset asics - [chars] 

Explanation    The ASICs on the OSM are resetting. System traffic should recover and continue normally after the module resets.

Recommended Action    No action is required.

Error Message    %CWTLC-4-MEDUSAERROR: Medusa Error. [chars] 

Explanation    The CWTLC Medusa ASIC received a recoverable error.

Recommended Action    No action is required if traffic recovers. If traffic does not recover, contact your Cisco technical support representative.

Error Message    %CWTLC-4-PINNACLE_OLDIOFPGA: Link negotiation maybe be affected, 
upgrade I/O FPGA 

Explanation    The system detected an older release of the I/O FPGA software. The I/O FPGA software needs to be upgraded to the latest release.

Recommended Action    Upgrade the I/O FPGA software to the newest release. If you require assistance, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-4-TMC_INVALID_STATID: PXF:Invalid-Statid ([dec]) for vc [int] 
under interface [int] 

Explanation    The OSM has encountered an internal error while setting up the statistics system.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC-5

Error Message    %CWTLC-5-BUS_SEQ_ERR: Constellation bus Sequence Error. Resetting port 
ASICS. 

Explanation    The SP detected a sequence error on the backplane bus of the OSM. The system called a reset sequence from the EARL to recover from this error. System traffic should recover and continue normally.

Recommended Action    If traffic recovers, no action is required. If traffic does not recover, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-5-DATAPATH_RECOVERY_PATCH: EARL reset patch invoked.

Explanation    The ASICs on the OSM were reset so that the module could recover from a bus sequence error. This condition usually occurs under heavy traffic with HA-related switchover or a module OIR operation. System traffic should recover and continue normally.

Recommended Action    If traffic recovers, no action is required. If traffic does not recover, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC-5-MEDUSA_RE_INIT: Medusa Re-initialize. 

Explanation    The OSM Medusa ASIC is being reinitialized because of a system backplane bus sequence error or a fatal ASIC error on the module itself.

Recommended Action    If traffic recovers, no action is required. If traffic does not recover, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC_ATOM Messages

This section contains Any Transport over MPLS (AToM) messages for WAN Optical Services Modules (CWTLC_ATOM).

CWTLC_ATOM-3

Error Message    %CWTLC_ATOM-3-OSM_BB1_CONFIG_UNSUPPORTED: Attempt to configure Frame 
Relay over MPLS or Frame Relay localswitching on a non-enhanced OSM 

Explanation    Frame Relay over MPLS and Frame Relay local switching features are supported only on enhanced Optical Services Modules. Nonenhanced OSMs do not support these features.

Recommended Action    Remove the configuration of the unsupported features, or upgrade this module to an enhanced OSM.

CWTLC_CHOC Messages

This section contains Cyclops Channelized OC48/OC12 (CWTLC_CHOC) messages.

CWTLC_CHOC-3

Error Message    %CWTLC_CHOC-3-HWERROR: [chars] 

Explanation    The module hardware has experienced the specified error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC_CHOCX Messages

This section contains Optical Services Module (OSM) Channelized OC12/OC3 module (CWTLC_CHOCX) messages.

CWTLC_CHOCX-3

Error Message    %CWTLC_CHOCX-3-HWERROR: [chars] 

Explanation    The module hardware has experienced the specified error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC_GEWAN Messages

This section contains Gigabit Ethernet WAN module (CWTLC_GEWAN) messages.

CWTLC_GEWAN-3

Error Message    %CWTLC_GEWAN-3-GEMAC_9K_MODE_FIX_FAILED: Fix for 9k buffer mode failed 
for GEMAC[[dec]] 

Explanation    An error has occurred while the system was setting the GEMAC component of the Gigabit Ethernet WAN module in 9,000-buffer mode (a buffer mode that supports jumbo frames). This condition occurred on the port specified in the error message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC_GEWAN-3-GEMAC_INIT_FAILED: Device initialization failed for 
GEMAC[[dec]] 

Explanation    An error occurred during initialization of the GEMAC device.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC_GEWAN-3-ZICO_INIT_FAILED: Device initialization failed for Zico 
FPGA[[dec]] 

Explanation    An error occurred during initialization of the protocol converter FPGA.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC_GEWAN-4

Error Message    %CWTLC_GEWAN-4-LINKFPGA_INTR: Index[[dec]] Cause[[hex]]: [chars] 

Explanation    The Link FPGA component on the Gigabit Ethernet WAN module has caused an error interrupt.

Recommended Action    Reload the module. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC_GEWAN-5

Error Message    %CWTLC_GEWAN-5-GEMAC_INTR: [chars]: [chars] 

Explanation    The GEMAC component of the Gigabit Ethernet WAN module caused an error interruption.

Recommended Action    Reload the module. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %CWTLC_GEWAN-5-LINKFPGA_INTR: Index[[dec]] Cause[[hex]]: [chars] 

Explanation    The link FPGA component of the Gigabit Ethernet WAN module caused an error interruption to occur.

Recommended Action    Reload the module. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

CWTLC_RP Messages

This section contains WAN Toaster-based module route processor (CWTLC_RP) messages.

CWTLC_RP-3

Error Message    %CWTLC_RP-3-TMEM_IMPROPER_SEL: Improperly nested PXF [int] memory 
select/deselect at nested level [int]. Value stored with select ([hex]) does not 
match the value passed with deselect ([hex]) 

Explanation    The last Parallel Express Forwarding (PXF) select operation was not followed by a deselect operation.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

DATACORRUPTION Messages

This section contains data corruption (DATACORRUPTION) messages.

DATACORRUPTION-1

Error Message    %DATACORRUPTION-1-DATAINCONSISTENCY: [chars], -PC= [hex] 

Explanation    The system has detected that some internal data structures may be corrupt. This condition can lead to unpredictable device operation, including, but not limited to, unexpected reloads or spurious memory accesses. This detection is a proactive check for operating system consistency.

Recommended Action    Note any other error messages or error symptoms that accompany this message. Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

DHCP_SNOOPING Messages

This section contains Dynamic Host Configuration Protocol Snooping (DHCP_SNOOPING) messages.

DHCP_SNOOPING-3

Error Message    %DHCP_SNOOPING-3-DHCP_SNOOPING_INTERNAL_ERROR: DHCP Snooping internal 
error, [chars] 

Explanation    A software verification test failed in the DHCP snooping process.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

DHCP_SNOOPING-4

Error Message    %DHCP_SNOOPING-4-DHCP_SNOOPING_RATE_LIMIT_EXCEEDED: The interface 
[chars] is receiving more than the threshold set 

Explanation    DHCP packets are coming into the RP at a much higher rate than the specified threshold.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %DHCP_SNOOPING-4-INVALID_RELEASE_OR_DECLINE_PKT: The interface 
[chars] has received a DHCP Release/Decline packet 
with no existing binding entry for it

Explanation    A DHCP release/decline packet was received with no corresponding binding entry.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %DHCP_SNOOPING-4-OPTION82_INSERTION_FAIL: The interface [chars] is not 
able to insert opt82 into the packet because of insufficient space in the packet 

Explanation    A DHCP packet was not inserted with opt82 data due to insufficient space in the packet.

Recommended Action    No action is required. This message is for informational purposes only.

DHCP_SNOOPING-5

Error Message    %DHCP_SNOOPING-5-DHCP_SNOOPING_MATCH_MAC_FAIL: [chars] drop message 
because the chaddr doesn't match source mac, message type: [chars], chaddr: 
[enet], MAC sa: [enet] 

Explanation    DHCP snooping enables match-source-mac validation and the check has failed. There maybe a malicious host trying to carry out a DOS attack on the DHCP server.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %DHCP_SNOOPING-5-DHCP_SNOOPING_NONZERO_GIADDR: [chars] drop message 
with non-zero giaddr or option82 value on untrusted port, message type: [chars], 
MAC sa: [enet] 

Explanation    DHCP snooping discovers a DHCP packet with an option value that is not allowed on an untrusted port. A malicious host may be trying to act as a DHCP relay or server.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %DHCP_SNOOPING-5-DHCP_SNOOPING_UNTRUSTED_PORT: [chars] drop message 
on untrusted port, message type: [chars], MAC sa: [enet] 

Explanation    DHCP snooping discovers a DHCP packet with an option value that is not allowed on an untrusted port. A malicious host may be trying to act as a DHCP relay or server.

Recommended Action    No action is required. This message is for informational purposes only.

DIAG Messages

This section contains Online Diagnostics (DIAG) messages.

DIAG-3

Error Message    %DIAG-3-ALWAYS_ENABLE_TEST: [chars]: The users are not allow to 
disable monitoring for Test #[dec] 

Explanation    The specified health monitoring test cannot be disabled.

Recommended Action    No action is required. The system is working properly.

Error Message    %DIAG-3-FIXED_INTERVAL_TEST: [chars]: The users are not allow to 
change monitoring interval of Test #[dec] 

Explanation    The specified health monitoring test interval cannot be changed.

Recommended Action    No action is required. The system is working properly.

Error Message    %DIAG-3-INVALID_DEVICE: Invalid device number : [chars]

Explanation    The system made a diagnostics request on a device that does not exist.

Recommended Action    Ensure that the specified device number exists and is valid.

Error Message    %DIAG-3-INVALID_MONITORING_INTERVAL: [chars]: The [chars][ID=[dec]] 
monitoring interval must be at least [dec] millisec 

Explanation    The specified test monitoring interval is too small.

Recommended Action    No action is required. The system is working properly.

Error Message    %DIAG-3-INVALID_TEST: Invalid test: [chars] 

Explanation    A test that does not exist was requested. [chars] describes the test.

Recommended Action    Ensure the specified test is supported by the switching module. The list of available tests and their associated test IDs can be retrieved using the show diagnostic content command.

Error Message    %DIAG-3-MONITOR_DISABLE: [chars]: The monitoring test:[dec] is disable 
since default interval is Zero 

Explanation    The specified test is no longer a health monitoring test.

Recommended Action    No action is required. The system is working properly.

Error Message    %DIAG-3-MONITOR_INTERVAL_ZERO: [chars]: Monitoring interval is 0. 
Cannot enable monitoring for Test #[dec] 

Explanation    The system cannot enable health monitoring for the specified test because the interval is set to zero.

Recommended Action    Reset the health monitoring interval for the test, and reenable health monitoring.

Error Message    %DIAG-3-NOT_MONITORING_TEST: [chars]: The test:[dec] cannot be used as 
health monitoring test 

Explanation    The specified test is not a health monitoring test.

Recommended Action    No action is required. The system is working properly.

Error Message    %DIAG-3-TEST_SKIPPED: [chars]: [chars]{ID=[dec]} is skipped 

Explanation    The diagnostic test cannot be run.

Recommended Action    No action is required. The system is working properly.

DIAG-4

Error Message    %DIAG-4-CONFIG_REAPPLY: Please reapply config command [chars] after 
the card is online. 

Explanation    This message appears when the specified configuration command cannot be applied. [chars] is the configuration command that you must reapply.

Recommended Action    The system is working properly and the specified command cannot be applied. Reapply the configuration command after the module is online.

DIAG-6

Error Message    %DIAG-6-SCHEDULE_IS_REMOVED: [chars]: Schedule Diagnostic for [[chars] 
[chars] [dec]:[dec].] is removed 

Explanation    The scheduled online diagnostics test was removed because the test is no longer applicable.

Recommended Action    No action is required. The system is working properly.

Error Message    %DIAG-6-SIMULATED_TEST_RESULT: [chars]: [chars] test result is 
simulated. 

Explanation    The result of the specified test is simulated. The message does not indicate a software or hardware fault. The first [chars] is the message notification and the second [chars] is the test name.

Recommended Action    No action is required. The test failure is simulated as specified by the user.

Error Message    %DIAG-6-SKIP_ONDEMAND_ACTIVE_TO_STANDBY_TEST: [chars]: [chars] cannot 
be executed. 

Explanation    The diagnostics test is bypassing the specified redundant test because the redundant test cannot be executed.

Recommended Action    No action is required. The system is working properly.

Error Message    %DIAG-6-TEST_SKIPPED_FROM_ACTIVE: [chars]: [chars] cannot be executed 
from active supervisor. 

Explanation    The specified test cannot be run from the active supervisor engine.

Recommended Action    No action is required. The test cannot be run, but the system is working properly.

DOT1X Messages

This section contains IEEE 802.1X (DOT1X) messages.

DOT1X-5

Error Message    %DOT1X-5-ERR_PVLAN: Dot1x cannot be enabled on private vlan port 
[chars] 

Explanation    802.1X could not be enabled on the specified private VLAN port. This condition was caused by trying to set 802.1X port control to auto mode on a PVLAN port.

Recommended Action    Change the port to access or routed mode, and retry enabling 802.1X on the port.

Error Message    %DOT1X-5-ERR_PVLAN_EQ_VVLAN: Dot1x can not be enabled on a port with 
Access VLAN equal to Voice VLAN. 

Explanation    A port could not enable 802.1X because the access VLAN is equal to a voice VLAN. This condition was caused by trying to set 802.1X port control to auto or force-unauthorized mode on a voice VLAN that is equal to an access VLAN port.

Recommended Action    Change the voice VLAN or the access VLAN on the interface, and retry the 802.1X operation.

Error Message    %DOT1X-5-ERR_RADIUSVLAN_EQ_VVLAN: RADIUS attempted to assign a VLAN to 
Dot1x port [chars] whose Voice VLAN is same as AccessVlan 

Explanation    The RADIUS server attempted to assign a VLAN to a supplicant on a port with a voice VLAN that is equal to an access VLAN.

Recommended Action    Either update the RADIUS configuration so that an access VLAN is not equal to voice VLAN or change the voice VLAN on the specified port.

Error Message    %DOT1X-5-ERR_STATIC_MAC: Dot1x can not be enabled on a port configured 
with Static MAC addresses. 

Explanation    A port could not enable 802.1X because the port is configured with static MAC addresses. This condition was caused by trying to set 802.1X port control to auto or force-unauthorized mode on a port that is configured with static MAC addresses.

Recommended Action    Remove the static MAC addresses on the port, and retry the 802.1X operation.

EAP Messages

This section contains Extensible Authentication Protocol (EAP) messages.

EAP-2

Error Message    %EAP-2-PROCESS_ERR: [chars] 

Explanation    A critical condition prevents the system from performing an operation related to an EAP process.

Recommended Action    Reload the system.

EAP-4

Error Message    %EAP-4-BADPKT: IP=[IP_address]| HOST=[chars] 

Explanation    The system received an invalid or malformed EAP packet from the specified host.

Recommended Action    Check the specified host for the EAP operation.

EAP-6

Error Message    %EAP-6-MPPE_KEY: IP=[chars]| MPPE_RECV_KEY_LENGTH=[dec] 

Explanation    The system received an MPPE key for the specified host.

Recommended Action    No action is required.

EARL Messages

This section contains Enhanced Address Recognition Logic (EARL) messages.

EARL-0

Error Message    %EARL-0-TASK_SPAWN_FAIL: Failed to initialize task "[chars]"

Explanation    The EARL component failed to start a task required by the system to work properly. The task name is specified in the error message. Most errors will cause a system reload. However, in some cases, only the feature that failed to start will be affected.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL-2

Error Message    %EARL-2-PATCH_INVOCATION_LIMIT: [dec] Recovery patch invocations in 
the last 30 secs have been attempted. Max limit reached 

Explanation    The system attempted the EARL recovery for the maximum number of times that are permitted in the last 30 seconds.

Recommended Action    The module has been automatically reset instead of attempting recovery.

Error Message    %EARL-2-SWITCH_BUS_IDLE: Switching bus is idle for [dec] seconds 

Explanation    The EARL did not switch any packets on the EARL bus. A recovery mechanism will attempt to fix the problem. The system reloads if the problem cannot be corrected.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL-2-SWITCH_BUS_STALL: Switching bus stall detected. Backplane bus 
stall status: [dec] 

Explanation    The EARL did not switch any packets on the EARL bus. A recovery mechanism will attempt to fix the problem. The system reloads if the problem cannot be corrected.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL-3

Error Message    %EARL-3-FABRIC_CONNECTION : Recovering from sequence error detected on 
fabric connection.

Explanation    A sequence error was detected by the crossbar and bus fabric interface. This error can be fatal. Recovery is being attempted.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL-3-RESET_LC: Resetting module in slot [dec]. (Errorcode [dec]) 

Explanation    The specified module did not respond to a critical message. This condition indicates a hardware error and might be a transient error only. The system has reset the module to fix the error.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL-4

Error Message    %EARL-4-BUS_CONNECTION : Interrupt [chars] occurring in EARL bus 
connection.

Explanation    An error interrupt is occurring for the switching bus interface.

Recommended Action    Enter the show earl status command on the consoles of the switch supervisor engine and any DFC-enabled modules. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL-4-EBUS_SEQ_ERROR: Out of Sync error. 

Explanation    The EARL has detected an out of synchronization condition on the bus. A recovery mechanism will attempt to fix the problem.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL-4-NF_USAGE: Current Netflow Table Utilization is [dec]% 

Explanation    NetFlow table utilization exceeds a preset threshold percentage.

Recommended Action    No action is required.

EARL_ACL_FPGA Messages

This section contains Enhanced Address Recognition Logic ACL field-programmable gate array (EARL_ACL_FPGA) messages.

EARL_ACL_FPGA-2

Error Message    %EARL_ACL_FPGA-2-INTR_FATAL: EARL ACL FPGA : Non-fatal interrupt 
[chars] 

Explanation    The EARL ACL FPGA detected the specified unexpected fatal condition. This message indicates a hardware failure or malfunction. The system will reload to attempt to fix the problem.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_ACL_FPGA-3

Error Message    %EARL_ACL_FPGA-3-INTR_WARN: EARL ACL FPGA : Non-fatal interrupt 
[chars] 

Explanation    The EARL ACL FPGA detected the specified unexpected nonfatal condition.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_ACL_FPGA-4

Error Message    %EARL_ACL_FPGA-4-CPU_PAR_ERR: EARL ACL FPGA : CPU Parity error [chars] 

Explanation    The EARL ACL FPGA detected a CPU parity error.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_ACL_FPGA-4-MEM_PAR_ERR: EARL ACL FPGA: Counter Memory Parity 
error. Error address [hex] 

Explanation    The EARL ACL FPGA detected a memory parity error.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_DRV_API Messages

This section contains Enhanced Address Recognition Logic Driver API (EARL_DRV_API) messages.

EARL_DRV_API -0

Error Message    %EARL_DRV_API-0-TASK_SPAWN_FAIL: Failed to spawn task "[chars]" 

Explanation    The system failed to launch the specified task.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_DRV_API-2

Error Message    %EARL_DRV_API-2-SIG_INST_FAIL: [chars]: Failed to install signal 
handler 

Explanation    The system failed to install the process signal handler.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_DRV_API-4

Error Message    %EARL_DRV_API-4-NOMEM: Malloc failed: [chars] [dec] 

Explanation    The system is running out of memory.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_L2_ASIC Messages

This section contains Enhanced Address Recognition Logic Layer 2 ASIC (EARL_L2_ASIC) messages.

EARL_L2_ASIC-0

Error Message    %EARL_L2_ASIC-0-EXCESSIVE_FT_TBL_ECC_ERR: EARL L2 ASIC [dec]: Too many 
bad entries in L2 Forwarding Table 

Explanation    The EARL Layer 2 ASIC detected too many errors in the forwarding table. This condition indicates hardware malfunction and causes the system to reload.

Recommended Action    If this problem is seen more than once, it could be a case of faulty hardware. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-0-FATAL_INTR: L2 Forwarding Engine: fatal interrupt: 
interrupt status [hex], interrupt mask [hex] 

Explanation    Critical interrupts might have caused system forwarding to cease.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_L2_ASIC-2

Error Message    %EARL_L2_ASIC-2-PARITY_ERR: L2 Forwarding Engine: parity interrupt 
#[dec]: address [hex], Data: [hex], [hex], [hex], [hex] 

Explanation    A parity error was detected while accessing the Layer 2 forwarding table.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_L2_ASIC-3

Error Message    %EARL_L2_ASIC-3-INTR_FATAL: EARL L2 ASIC [dec]: fatal interrupt 
[chars] 

Explanation    The EARL Layer 2 ASIC detected an unexpected fatal condition. This message indicates a hardware failure or malfunction. The system will reload to fix the problem.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-3-INTR_WARN: EARL L2 ASIC [dec]: Non-fatal interrupt 
[chars] 

Explanation    The EARL Layer 2 ASIC detected an unexpected nonfatal condition.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_L2_ASIC-4

Error Message    %EARL_L2_ASIC-4-DBUS_HDR_ERR: EARL L2 ASIC #[dec]: Dbus Hdr. Error 
occurred. Ctrl1 [hex] 

Explanation    The EARL Layer 2 ASIC detected an invalid header in the DBUS. This error is caused by hardware that has failed, a misconfiguration of the module software, or invalid packets that were dropped because of an OIR operation.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-4-DBUS_SEQ_ERR: EARL L2 ASIC #[dec]: Dbus Seq. Error 
occurred (Ctrl1 [hex]) 

Explanation    The EARL Layer 2 ASIC detected a DBUS sequence mismatch error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-4-FT_ERR: EARL L2 ASIC [dec]: Forwarding table bank 
[dec] encountered [chars] ecc error at address [hex] 

Explanation    The EARL Layer 2 ASIC detected a nonfatal condition in one of the banks of the forwarding table. The bank and address of the forwarding table is specified in the error message.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-4-FT_INVLD_ADDR: Forwarding table bank [dec] encountered 
invalid address [hex] 

Explanation    The EARL Layer 2 ASIC attempted to access an invalid address in the forwarding table. Because there are only 12 pages (0-11) per line, access to page 12-15 will be invalid.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-4-INTR_THROTTLE: Throttling "[chars]" interrupt 
exceeded permitted [int]/[dec] interrupts/msec 

Explanation    Excessive interrupts were generated by the EARL ASIC.

Recommended Action    Interrupt throttling has been performed to protect the supervisor engine. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-4-INV_REG: EARL L2 ASIC: Attempt to [chars] invalid 
register 

Explanation    An attempt was made to read or write to an invalid register of the EARL Layer 2 ASIC.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-4-L2L3_SEQ_ERR: EARL L2 ASIC #[dec]: L2L3 Mismatch seq 
#[hex] 

Explanation    The EARL Layer 2 ASIC detected a Layer 2 to Layer 3 sequence mismatch error. A recovery mechanism will attempt to fix the problem.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L2_ASIC-4-SRCH_ENG_FAIL: EARL L2 ASIC Search Engine has failed 

Explanation    The EARL Layer 2 ASIC Search Engine failed to terminate a search. A recovery mechanism fixes the unexpected condition.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_L3_ASIC Messages

This section contains Enhanced Address Recognition Logic Layer 3 ASIC (EARL_L3_ASIC) messages.

EARL_L3_ASIC-3

Error Message    %EARL_L3_ASIC-3-INTR_FATAL: EARL L3 ASIC: fatal interrupt [chars]

Explanation    The EARL Layer 3 ASIC detected an unexpected fatal condition. This message indicates a hardware failure or malfunction. The system will reload to attempt to fix the problem.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L3_ASIC-3-INTR_WARN: EARL L3 ASIC: Non-fatal interrupt [chars] 

Explanation    The EARL Layer 3 ASIC detected an unexpected nonfatal condition.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_L3_ASIC-4

Error Message    %EARL_L3_ASIC-4-CPU_PAR_ERR: EARL L3 ASIC: CPU Parity error. Error 
data [hex]. Error address [hex] 

Explanation    The EARL Layer 3 ASIC detected a CPU parity error. This condition is caused by an interprocess communication error between the CPU and the Layer 3 ASIC.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_L3_ASIC-4-INTR_THROTTLE: Throttling "[chars]" interrupt 
exceeded permitted [int]/[dec] interrupts/msec 

Explanation    Excessive interrupts were generated by the EARL ASIC.

Recommended Action    Interrupt throttling has been performed to protect the supervisor engine. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_NETFLOW Messages

This section contains Enhanced Address Recognition Logic NetFlow (EARL_NETFLOW) messages.

EARL_NETFLOW-0

Error Message    %EARL_NETFLOW-0-NF_ECC_MAX: Netflow ECC Error Threshold Reached, Total 
Ecc Errors [[dec]] 

Explanation    The total number of NetFlow ECC errors has crossed the maximum threshold. The maximum allowable of NetFlow ECC errors is 2000. The system will perform a crash dump and will be inoperable. The output of the show tech-support command will also be displayed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_NETFLOW-3

Error Message    %EARL_NETFLOW-3-NF_ECC_RSRV: Netflow ECC Error Occured, Reserved NF 
location [[hex]] 

Explanation    The number of ECC errors per NetFlow TCAM entry has reached the maximum threshold (three or more ECC errors). The NetFlow TCAM location will now be marked as reserved and can no longer be used.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_NETFLOW-3-NF_ECC_SOFT_MAX: Too many Netflow ECC errors have 
occurred, Total Ecc Errors [[dec]] 

Explanation    The total number of NetFlow ECC errors has exceeded the soft limit number. The soft limit of Netflow ECC errors is 2500. The hard limit is 5000. When the hard limit is reached, the line card will reboot.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_NETFLOW-4

Error Message    %EARL_NETFLOW-4-ICAM_THRLD: Netflow ICAM threshold exceeded, ICAM 
Utilization [[dec]%] 

Explanation    The NetFlow ICAM is almost full. Aggressive aging is temporarily enabled.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_NETFLOW-4-NF_AGG_CACHE_THR: Netflow [chars] aggregation cache is 
almost full. 

Explanation    The aggregation cache for NetFlow is almost full. This condition might cause a high CPU load.

Recommended Action    Consider increasing the size of the aggregation cache, or remove the aggregation cache configuration specified in the error message.

Error Message    %EARL_NETFLOW-4-NF_FULL: Netflow Table Full, ICAM occupancy [[dec]%], 
TCAM occupancy [[dec]%], Entry creation failures [[dec]] 

Explanation    The NetFlow table is full, possibly because of faulty hashing behavior.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EARL_NETFLOW-4-NF_TIME_SAMPLING: Time-based sampling requests could 
not be processed in time. 

Explanation    Time-based sampling requests could not be processed in a timely fashion. As a result, the sampling result might not be accurate.

Recommended Action    Consider using packet-based sampling. Packet-based sampling uses an algorithm that ensures the sampling results will be accurate, even if they are not processed in the allotted time.

Error Message    %EARL_NETFLOW-4-TCAM_THRLD: Netflow TCAM threshold exceeded, TCAM 
Utilization [[dec]%] 

Explanation    The NetFlow TCAM is almost full. Aggressive aging is temporarily enabled.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EARL_NETFLOW-5

Error Message    %EARL_NETFLOW-5-NF_ECC_REMOVE: Netflow ECC Error Occured, Deleted NF 
entry [[hex]] 

Explanation    A NetFlow ECC error occurred. The affected NetFlow entry has been deleted at the address specified so that a new entry will be created.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EC Messages

This section contains Port Aggregation Protocol, Link Aggregation Control Protocol shim, and EtherChannel (EC) messages.

EC-5

Error Message    %EC-5-MINLINKS_MET: Port-channel [chars] is up as its bundled ports 
([dec]) meets min-links 

Explanation    The administrative configuration of minimum links is equal to or less than the number of bundled ports. As a result, this port channel is operational.

Recommended Action    No action is required.

Error Message    %EC-5-MINLINKS_NOTMET: Port-channel [chars] is down bundled ports 
([dec]) doesn't meet min-links 

Explanation    The administrative configuration of minimum links is greater than the number of bundled ports. As a result, this port channel is not longer operational.

Recommended Action    Reduce the number of minimum links for the specified group, or add more ports to this port channel so that they bundle.

EM Messages

This section contains Event Manager (EM) messages.

EM-3

Error Message    %EM-3-EXCEED: EM exceed maximum open events ([dec]).

Explanation    The total number of open events exceeded the maximum number of possible open events. The maximum number that the EM server permits is specified in the error message. EM clients are either opening too many events or not closing events within the permitted time period.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show em state | inc em_type command to obtain data. Contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %EM-3-FAIL: The specified EM Function failed ([chars]). 

Explanation    The specified EM function failed. This condition might be caused by incorrect logic or a memory corruption.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show em state command and the show em status command to gather data that may help Cisco technical support to identify the nature of the error. Contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %EM-3-NOMEM: The EM failed to allocate memory resources for the 
specified EM function ([chars]). 

Explanation    The EM failed to allocate memory resources for the specified function because memory is running low.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show memory summary command to gather data that may help Cisco technical support to identify the nature of the error. Contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %EM-3-NULLPTR: The pointer in a specified EM function ([chars]) is 
incorrectly NULL. 

Explanation    The pointer in the specified EM function is incorrectly NULL. This condition might be caused by incorrect logic or a memory corruption.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show em state command and the show em status command to gather data that may help Cisco technical support to identify the nature of the error. Contact your Cisco technical support representative and provide the representative with the gathered information.

EM-4

Error Message    %EM-4-AGED: The specified EM client (type=[dec], id=[dec]) did not 
close the EM event within the permitted amount of time ([dec] msec). 

Explanation    A timeout occurred. This condition is minor and should not affect the functionality of the switch.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show em state command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show em state output, contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %EM-4-INVALID: The specified EM function ([chars]) received Invalid 
operands <[dec]>.

Explanation    The EM client used invalid API parameters.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show em state command and the show em status command to gather data that may help Cisco technical support to identify the nature of the error. Contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %EM-4-LIMIT: EM exceed open events limit ([dec]).

Explanation    The EM has exceeded the permitted number of open events. The open event limit is 5000.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EM-4-NOTUP: The EM is not available ([chars]).

Explanation    The EM is not available because some basic initialization failed. This condition might be caused by failure of a basic infrastructure functionality or a memory corruption.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show em state command and the show em status command to gather data that may help Cisco technical support to identify the nature of the error. Contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %EM-4-SEARCH: The EM function ([chars]) searched for the specified open 
event ([dec]), but the search failed. 

Explanation    The specified EM function could not find the specified open event. This condition might be caused by a memory corruption.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show em state command or the show em status command to gather data that may help Cisco technical support to identify the nature of the error. Contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %EM-4-SENDFAILED: The specified EM client (type=[dec]) failed to send 
messages to standby. 

Explanation    The redundant supervisor engine is not updated because the specified EM client failed to send messages to the redundant supervisor engine. Do not attempt to failover to redundant supervisor engine.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Enter the show checkpoint clients command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show checkpoint clients output, contact your Cisco technical support representative and provide the representative with the gathered information.

ENT_API Messages

This section contains Entity MIB API (ENT_MIB) messages.

ENT_API-4

Error Message    %ENT_API-4-NOALIAS: Physical entity not found when adding an alias with 
physical index = [dec] and logical index = [dec] to the Entity MIB

Explanation    This message indicates a timing issue when the system or the module is brought up. This issue has no impact on system performance or management functionality.

Recommended Action    No action is required.

ENVM Messages

This section contains environmental monitoring (ENVM) messages.

ENVM-2

Error Message    %ENVM-2-TEMP_SENSOR_READFAIL: Failed to access the Temperature sensor 
on the linecard. Resetting the linecard.

Explanation    The local CPU on the Enhanced FlexWAN module was unable to access the temperature sensor on the module. The module will attempt to recover by resetting itself.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

ENVM-3

Error Message    %ENVM-3-TEMP_SENSOR_DISABLED: Access to Temperature sensor on module 
in slot [dec] is disabled 

Explanation    During previous reloads, this module experienced a timeout while accessing the temperature sensor. All further access to the temperature sensor will be disabled. This condition indicates a possible problem with the temperature sensor.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EOBC Messages

This section contains Ethernet out-of-band channel (EOBC) messages.

EOBC-0

Error Message    %EOBC-0-EOBC_JAM_FATAL: [chars] in slot [dec] is jamming the EOBC 
channel.  It has been disabled.  

Explanation    The primary supervisor engine EOBC hardware is faulty. There is no redundant supervisor engine to take over, so the switch has been shut down.

Recommended Action    Immediately replace the supervisor engine in the slot specified in the error message.

EOBC-2

Error Message    %EOBC-2-EOBC_JAM: EOBC channel is jammed.  Attempting to diagnose the 
source of the problem and recover if possible. 

Explanation    The SP is unable to communicate with other processors in the system because of a problem with the EOBC channel. The problem could be due to faulty EOBC hardware on the supervisor engine or due to a module with a faulty connector to the EOBC channel. The SP will attempt to recover automatically. The success of this automatic recovery will be communicated through more messages.

Recommended Action    No action is required.

Error Message    %EOBC-2-EOBC_JAM_RECOVERED: [chars] in slot [dec] is jamming the EOBC 
channel.  It has been disabled. [chars] 

Explanation    The specified module has faulty hardware and is adversely affecting the operation of the switch. The remaining modules will be power cycled and brought online.

Recommended Action    Immediately replace the module in the slot specified in the error message.

EOBC-3

Error Message    %EOBC-3-NOEOBCBUF: No EOBC buffer available.  Dropping the packet. 

Explanation    The EOBC receive buffer pool has been exhausted. No further input packets can be processed until some buffers are returned to the pool.

Recommended Action    After buffers are returned to the pool, if processing continues normally, no action is required. Otherwise, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EOS Messages

This section contains Eos ASIC (EOS) messages.

EOS-2

Error Message    %EOS-2-EOS_INIT_FAILURE : The EOS FPGA initialization failed due to 
[chars]

Explanation    The Eos FPGA initialization was not successful because of a hardware problem with the board. This condition will cause packets to drop.

Recommended Action    Contact your Cisco technical support representative to obtain a replacement board.

Error Message    %EOS-2-EOS_INT : [chars]

Explanation    A fatal interrupt has occurred. As a result, the device has been reinitialized.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EOS-2-INT : [chars]

Explanation    A fatal interrupt has occurred. As a result, the device has been reinitialized.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EOS-2-NULL_EOS_OBJECT : The EOS device object pointer is set to NULL

Explanation    The memory location of the Eos device object is invalid. The Eos FPGA operation is disabled and the device interrupt is now masked.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EOS-3

Error Message    %EOS-3-EOS_PAUSE_FAIL: [chars] 

Explanation    An attempt to pause the forwarding of traffic from an Eos ASIC interface FPGA to another ASIC has timed out. Depending on the status register value of the ASIC interface FPGA, traffic disruption might occur.

Recommended Action    If normal traffic processing does not resume, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EOS-3-EOS_UNPAUSE_FAIL : EOS status register is 0x[hex]

Explanation    An attempt to unpause traffic from the Eos FPGA to the Hyperion ASIC timed out. This condition may lead to traffic disruption.

Recommended Action    If normal traffic processing does not resume, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EOS-3-QUEUE_ALLOC_FAILED: Failed to allocate queue in the EOS FPGA 
for SPA in bay ([dec]) 

Explanation    The system failed to allocate the Eos ASIC queue for the SPA in the specified bay. This condition might lead to traffic disruption.

Recommended Action    If normal traffic processing does not resume, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EOS-4

Error Message    %EOS-4-EOS_WARN_INT: [chars] 

Explanation    The Eos ASIC interface FPGA received a nonfatal interrupt. This interrupt should not affect normal operation.

Recommended Action    No action is required.

EOS-5

Error Message    %EOS-5-PAUSE_FAIL: [chars] 

Explanation    An attempt to pause the forwarding of traffic from an Eos ASIC interface FPGA to another ASIC has timed out. Depending on the status register value of the ASIC interface FPGA, traffic disruption might occur.

Recommended Action    If normal traffic processing does not resume, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EOU Messages

This section contains Extensible Authentication Protocol over UDP (EOU) messages.

EOU-2

Error Message    %EOU-2-PROCESS_ERR: Router could not create a EAPoUDP process 

Explanation    The system could not create an Extensible Authentication Protocol over UDP (EOU) process.

Recommended Action    Reload the system.

EOU-4

Error Message    %EOU-4-BAD_PKT: IP=[IP_address]| Bad Packet=[chars] 

Explanation    The system received an invalid or malformed EAP packet from the specified host.

Recommended Action    Check the specified host for the EAP operation.

Error Message    %EOU-4-MSG_ERR: Unknown message event reveived 

Explanation    The EOU authentication process received an unknown message event.

Recommended Action    If this message recurs, reload the system.

Error Message    %EOU-4-PROCESS_STOP: PROCESS=[chars]| ACTION=[chars]. 

Explanation    The specified process has stopped.

Recommended Action    Reload the system.

Error Message    %EOU-4-SOCKET: EAPoUDP socket binding fails for PORT=[hex]. Check if 
the interface has valid IP address. 

Explanation    The EOU socket could not bind its port to an valid interface address.

Recommended Action    This condition is probably caused by a missing IP address on the interface. Configure a valid IP address for the interface.

Error Message    %EOU-4-UNKN_EVENT_ERR: UNKNOWN Event for HOST=[IP_address]| 
Event=[dec]. 

Explanation    This message indicates an unknown event for the EOU process.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EOU-4-UNKN_PROCESS_ERR: An unknown operational error occurred. 

Explanation    The EOU process cannot function due to an internal system error.

Recommended Action    Reload the system.

Error Message    %EOU-4-UNKN_TIMER_ERR: An unknown Timer operational error occurred 

Explanation    The EOU process cannot function because of an internal system error.

Recommended Action    Reload the system.

Error Message    %EOU-4-VALIDATION: Unable to initiate validation for 
HOST=[IP_address]| INTERFACE=[chars]. 

Explanation    The EOU could not start posture validation for the specified host. This condition is probably caused by a failure to bind the EOU port.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EOU-4-VERSION_MISMATCH: HOST=[IP_address]| Version=[dec] 

Explanation    The specified host detected a mismatch in EOU versions.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

EOU-5

Error Message    %EOU-5-RESPONSE_FAILS: Received an EAP failure response from AAA for 
host=[IP_address] 

Explanation    The system received an EAP failure response from AAA, which indicates the unsuccessful validation of host credentials.

Recommended Action    No action is required.

EOU-6

Error Message    %EOU-6-AUTHSTATUS: [chars]|[IP_address] 

Explanation    This message displays the authentication status (Success, Failure) for the specified host.

Recommended Action    This message is informational. No action is required.

Error Message    %EOU-6-AUTHTYPE: IP=[IP_address]| AuthType=[chars] 

Explanation    This message displays the authentication type for the specified host.

Recommended Action    This message is informational. No action is required.

Error Message    %EOU-6-CTA: IP=[IP_address]| CiscoTrustAgent=[chars] 

Explanation    This message indicates whether or not Cisco Trust Agent was detected on the specified host.

Recommended Action    Install Cisco Trust Agent on the host if it was not detected.

Error Message    %EOU-6-IDENTITY_MATCH: IP=[IP_address]| PROFILE=EAPoUDP| 
POLICYNAME=[chars] 

Explanation    The system found the specifed host in the EOU identity profile, which means that there will be no EOU association with the host and the local policy.

Recommended Action    If you do not want the specified host to be exempted from authentication, remove its entry from EOU identity profile.

Error Message    %EOU-6-POLICY: IP=[IP_address]| [chars]=[chars] 

Explanation    The system received policy attributes from AAA for the specified host.

Recommended Action    This message is informational. No action is required.

Error Message    %EOU-6-POSTURE: IP=[IP_address]| HOST=[chars]| Interface=[chars] 

Explanation    This message displays the posture validation status for the specified host.

Recommended Action    This message is informational. No action is required.

Error Message    %EOU-6-SESSION: IP=[IP_address]| HOST=[chars]| Interface=[chars] 

Explanation    An entry was created or deleted for the host on the specified interface.

Recommended Action    This message is informational. No action is required.

Error Message    %EOU-6-SQ: IP=[IP_address]| STATUSQUERY|[chars] 

Explanation    The status query result for the specified host either failed or was invalid.

Recommended Action    This message is informational. No action is required.

EPLD_STATUS_OPEN Messages

This section contains EPLD programming status file data processing (EPLD_STATUS_OPEN) messages.

EPLD_STATUS_OPEN-4

Error Message    %EPLD_STATUS_OPEN-4-ERROR_ALLOC: %Error: Can't allocate [dec] bytes 
for epld status data 

Explanation    The system is unable to allocate required memory to access the file.

Recommended Action    Determine the memory usage of the system, and retry the operation.

Error Message    %EPLD_STATUS_OPEN-4-ERROR_OPEN: %Error: Can't open [chars] 

Explanation    The system is unable to open the specified file.

Recommended Action    Ensure that the filename is correct. Enter the dir command to verify the filename.

Error Message    %EPLD_STATUS_OPEN-4-ERROR_READ: %Error: status file [chars] read 
failed 

Explanation    An unknown error occurred while the system was reading the status program file to a local buffer.

Recommended Action    Delete and recopy the file. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EPLD_STATUS_OPEN-4-ERROR_REMOVE: %Error: status file [chars] remove 
failed 

Explanation    An unknown error occurred while the system was removing the status program file from nonvolatile memory.

Recommended Action    Delete the file manually. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %EPLD_STATUS_OPEN-4-ERROR_SIZE: %Error: Bad file size [chars] 

Explanation    The file is too small or too large for a programming status file.

Recommended Action    Enter the dir command, and determine the size of the file. Retry the operation.

Error Message    %EPLD_STATUS_OPEN-4-ERROR_WRITE: %Error: status file [chars] write 
failed 

Explanation    An unknown error occurred while the system was writing the status program file to nonvolatile memory.

Recommended Action    Delete and recopy the file. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

FABRIC Messages

This section contains fabric (FABRIC) messages.

FABRIC-3

Error Message    %FABRIC-3-LOST_SYNC: [chars] endpoint of fpoe:[dec] lost Sync. to 
[chars] fabric,#[dec] times recovered success, trying to recover now! 

Explanation    A fabric channel is reported to be out of synchronization. The system will attempt to synchronize the channel now.

Recommended Action    This message is informational only. No action is required.

FIB Messages

This section contains Forwarding Information Base (FIB) messages.

FIB-2

Error Message    %FIB-2-FIBRETRY_EXCEEDED: CEF table download to slot [dec] not 
performed as IPC port did not come up 

Explanation    The FIB could not be fully downloaded. As a result of this condition, hardware switching might not be functional on the module.

Recommended Action    Reset the module to overcome this condition.

FIB-4

Error Message    %FIB-4-FIBRETRY_WARNING: IPC port for slot [dec] to become available 
for CEF table download (retried [dec] times) 

Explanation    The FIB table failed to download for the number of times specified in the message.

Recommended Action    If the FIB table is successfully downloaded in a subsequent retry, no action is required. If the operation is not successful, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

FILESYS Messages

This section contains file system (FILESYS) messages.

FILESYS-3

Error Message    %FILESYS-3-RUNNING_SYNC_FAILED: The active is unable to synchronize 
the running configuration to standby, so standby will be reloaded 

Explanation    The active supervisor engine cannot access its running configuration to synchronize the configuration to the standby supervisor engine. This can be caused by temporary resource issues such as high CPU.

Recommended Action    No action is required. This message is for informational purposes only.

FM Messages

This section contains Feature Manager (FM) messages.

FM-2

Error Message    %FM-2-ACL_MERGE_EXCEPTION: ACL merge internal error due to features 
configured on interface [chars] in [chars] direction, traffic may be switched in 
software 

Explanation    The configured features for this interface caused the merge to abort because of an internal error. The traffic on this interface and the interfaces sharing TCAM label with this interface will be sent to the software.

Recommended Action    Redefine and reapply or unconfigure one or more features on the interface.

Error Message    %FM-2-ACL_MERGE_NUM_ACES: ACL merge aborted due to number of ACEs 
threshold for features on interface [chars] in [chars] direction, traffic may be 
switched in software 

Explanation    The configured features for this interface may have caused the merge to abort because of hitting the 64000 ACE merge threshold. The traffic on this interface and the interfaces sharing the TCAM label with this interface will be sent to the software.

Recommended Action    Redefine and reapply or unconfigure one or more features on the interface.

Error Message    %FM-2-FIE_EXCEPTION: Feature interaction internal error due to 
features configured on interface [chars] in [chars] direction, traffic may be 
switched in software 

Explanation    The configured features for this interface caused an internal error in the feature interaction. The traffic on this interface and the interfaces sharing the TCAM label with this interface will be sent to the software.

Recommended Action    Redefine and reapply or unconfigure one or more features on the interface.

Error Message    %FM-2-FLOWMASK_CONFLICT: Features configured on interface [chars] have 
conflicting flowmask requirements, traffic may be switched in software 

Explanation    The configured features for this interface have a flow mask conflict. The traffic on this interface and the interfaces sharing the TCAM label with this interface may not comply with the features under this condition. The traffic on these interfaces will be sent to the software.

Recommended Action    Redefine and reapply or unconfigure one or more features to avoid the conflict.

Error Message    %FM-2-TCP_FLAG_HW_EXCEPTION: No VLOUs available for TCP FLAGs for 
interface [chars] in [chars] direction: all features on the interface for the 
specified direction will be NOT effective 

Explanation    No VLOUs are available for TCP flags. This condition cannot be handled in the software for all the features configured on the interface. A message is printed on the console to notify the user of this error condition. Because there are no features that the software can handle, the system will program an entry to permit all traffic.

Recommended Action    The hardware TCAM can handle up to 9 logical operations per interface and up to 64 logical operations in total. To recover from this error, recompute the ACLs for the features that cannot be handled in the software (for example, VACLs) to move entries using TCP flags before others entries are moved and to minimize the usage of TCP flags.

Error Message    %FM-2-TCP_FLAG_SW_EXCEPTION: No VLOUs available for TCP FLAGs on 
interface [chars] in [chars] direction: traffic will be software switched, 
features which are NOT processable in software will be NOT effective 

Explanation    No VLOUs are available for TCP flags. This condition cannot be handled in the software for some features configured on the interface. A message is printed on the console to notify the user of this error condition. Because there are some features that can be handled in the software (for example, VACLs and RACLs), an exception entry and traffic on this interface will be sent to the software.

Recommended Action    The hardware TCAM can handle up to 9 logical operations per interface and up to 64 logical operations in total. To recover from this error, recompute the ACLs for the features that cannot be handled in the software (for example, VACLs) to move entries using TCP flags before others entries are moved and to minimize the usage of TCP flags.

FM-4

Error Message    %FM-4-FLOWMASK_REDUCED: Features configured on interface [chars] have 
conflicting flowmask requirements, some features may work in software 

Explanation    The configured features for this interface have a flow mask conflict. The traffic on this interface and the interfaces sharing the TCAM label with this interface will be sent to the software.

Recommended Action    Redefine and reapply or unconfigure one or more features to avoid the conflict.

Error Message    %FM-4-L2_DYN_TCAM_EXCEPTION: Failed to install Dynamic TCAM entry to 
filter Layer 2 traffic, error status: [dec], host IP address: [IP_address], 
interface: [chars] 

Explanation    There is an error in installing the per-user policies in the Dynamic TCAM region to filter Layer 2 traffic. The TCAM might be full. As a result, host ingress traffic will be subjected to the default interface ACL.

Recommended Action    Attempt to free up TCAM resources.

Error Message    %FM-4-L2EOU_INSP: INSPECTION & L2EOU conflict on i/f [chars] 

Explanation    The inspection feature and the L2EOU feature are not supported on the same VLAN. The inspection feature will be inactive. To activate the inspection feature, reconfigure it after removing the L2EOU feature.

Recommended Action    Remove either the L2EOU feature or the inspection feature from the interface.

Error Message    %FM-4-L2EOU_VACL: VACL Capture & L2EOU conflict on i/f [chars] 

Explanation    VACL capture and the L2EOU feature are not supported on the same VLAN port. VACL capture will be inactive. To activate VACL capture, reconfigure the feature after removing the L2EOU feature.

Recommended Action    Remove either the L2EOU feature or VACL capture on this interface.

Error Message    %FM-4-PISA-INSP: INSPECION & FPM/NBAR conflict on i/f [chars]

Explanation    The inspection feature and FPM/NBAR are not supported on the same interface. The inspection feature remains inactive. To activate the inspection feature, reconfigure it after removing FPM/NBAR from the interface.

Recommended Action    Remove either FPM/NBAR or the inspection feature from this interface.

Error Message    %FM-4-TCAM_ADJ: Hardware ACL adjacency capacity exceeded 

Explanation    The hardware does not have the capacity to handle all of the configured adjacencies.

Recommended Action    The configured policies have too many adjacencies to fit in the hardware. Use the mls tcam priority command to prioritize interfaces for hardware switching. Reduce the number of adjacencies in the policies.

Error Message    %FM-4-TCAM_DYN_ENTRY_EXCEPTION: Failed to install Dynamic TCAM entry 
in TCAM for Interface:[chars] 

Explanation    Dynamic installation of an ACE failed because of TCAM resource exhaustion. Layer 3 traffic will be handled by the software.

Recommended Action    Attempt to free up TCAM resources.

FMCORE Messages

This section contains Core Feature Manager (FMCORE) messages.

FMCORE-2

Error Message    %FMCORE-2-ACL_FAILURE: Interface [chars] traffic will not comply with 
ACLs in [chars] direction(s) 

Explanation    ACLs will not be applied on traffic for the specified interface because of a TCAM resource contention.

Recommended Action    The configured ACLs are too large for all of them to fit in the hardware TCAM. Use the mls tcam priority command to prioritize interfaces for hardware switching. Try to share the same ACLs across multiple interfaces to reduce TCAM resource contention.

Error Message    %FMCORE-2-VACL_FAILURE: Interface [chars] traffic will not comply with 
VACLs in [chars] direction(s) 

Explanation    VACLs will not be applied on traffic for this interface because of a TCAM resource contention.

Recommended Action    The configured ACLs are too large for all of them to fit in the hardware TCAM. Use the mls tcam priority command to prioritize interfaces for hardware switching. Try to share the same ACLs across multiple interfaces to reduce TCAM resource contention.

FMCORE-4

Error Message    %FMCORE-4-RACL_REDUCED: Interface [chars] routed traffic will be 
software switched in [chars] direction 

Explanation    A TCAM resource contention prevents ACLs from being applied in the TCAM for the specified interface. The traffic on the interface will be sent to software so that the ACLs can be applied.

Recommended Action    The configured ACLs are too large for all of them to fit in the hardware TCAM. Use the mls tcam priority command to prioritize interfaces for hardware switching. Try to share the same ACLs across multiple interfaces to reduce TCAM resource contention.

FM_EARL6 Messages

This section contains Enhanced Address Recognition Logic 6 Feature Manager (FM_EARL6) messages.

FM_EARL6-4

Error Message    %FM_EARL6-4-RACL_REDUCED_MCAST_RATELIM_WARN: Enabling acl [chars] 
rate-limiter will cause Multicast traffic to be dropped in hardware on interface 
[chars] in [chars] direction 

Explanation    A TCAM resource contention prevents routed ACLs from being programmed in the TCAM for the specified interface in the specified direction. All Layer 3 traffic will be sent to CPU to have RACLs enforced in software. Due to a lack of resources, multicast special VMRs cannot be programmed. In this condition, rate limiting for traffic bridged to the CPU by the ACL is incompatible with the status of the multicast interface and will cause multicast traffic to be dropped in the hardware.

Recommended Action    Do not configure the mls unicast acl {input | output} command.

Error Message    %FM_EARL6-4-VACL_PVLAN: Vacl config is NOT supported on secondary 
Vlan: [chars] and will be removed 

Explanation    Current implementation of the FM does not support the configuration of VACLs on secondary VLANs. The VACL configuration is removed from the VLAN interface once it becomes a secondary private VLAN. Both the hardware and the software will be updated accordingly.

Recommended Action    Make the VLAN a primary VLAN or a regular (nonprivate) VLAN. Reapply the VLAN filter.

FM_EARL7 Messages

This section contains Enhanced Address Recognition Logic 7 Feature Manager (FM_EARL7) messages.

FM_EARL7-2

Error Message    %FM_EARL7-2-IPV6_PORT_QOS_MCAST_FLOWMASK_CONFLICT: QoS configuration 
on port [chars] conflicts for flowmask with IPv6 multicast forwarding on SVI 
interface [chars] 

Explanation    The port-based QoS microflow policing configuration for this interface has a flow mask conflict with IPv6 multicast forwarding. The traffic on the SVI interface will be sent to the software under this condition.

Recommended Action    Unconfigure the latest configuration change, modify the conflicting QoS configuration, and reapply.

Error Message    %FM_EARL7-2-IPV6_QOS_MCAST_FLOWMASK_CONFLICT: QoS configuration on 
interface [chars] conflicts for flowmask with IPv6 multicast forwarding, traffic 
may be switched in software 

Explanation    The QoS microflow policing configuration for this interface has a flow mask conflict with IPv6 multicast forwarding. The traffic on this interface will be sent to the software under this condition.

Recommended Action    Unconfigure the latest configuration change, modify the conflicting QoS configuration, and reapply.

Error Message    %FM_EARL7-2-SWITCH_PORT_QOS_FLOWMASK_CONFLICT: QoS configuration on 
switch port [chars] conflicts for flowmask with feature configuration on SVI 
interface [chars] 

Explanation    The QoS configuration on the specified port has a conflict with a feature configuration on an SVI interface. QoS or other features might not function correctly under these circumstances.

Recommended Action    Unconfigure the latest configuration change, modify the conflicting configuration, and reapply the features.

FM_EARL7-4

Error Message    %FM_EARL7-4-FEAT_FLOWMASK_REQ_CONFLICT: Feature [chars] requested 
flowmask [chars] conflicts with other features on interface [chars], flowmask 
request Unsuccessful for the feature 

Explanation    The flow mask requested by the specified feature conflicts with other features. The requested flow mask cannot be programmed for the feature.

Recommended Action    Redefine and reapply the feature, or unconfigure one or more features and reapply the specified feature to avoid the conflict.

Error Message    %FM_EARL7-4-FEAT_FLOWMASK_REQ_CONFLICT_ON_SP: Flowmask requested on 
interface [chars] conflicts with other features on interface for Protocol [chars], 
flowmask request Unsuccessful for the feature 

Explanation    The flow mask requested by the feature conflicts with other features. The requested flow mask cannot be programmed for the feature.

Recommended Action    Redefine and reapply the feature, or reconfigure one or more features and reapply the feature to avoid the conflict.

Error Message    %FM_EARL7-4-FEAT_QOS_FLOWMASK_CONFLICT:Features configured on 
interface [chars] conflict for flowmask with QoS configuration on switch port 
[chars], traffic may be switched in software 

Explanation    The configured features for the specified interface have flow mask conflicts with the QoS configuration on the switch port. The traffic on this interface will be sent to software.

Recommended Action    Back out of the latest configuration change, modify the conflicting QoS configuration on the switch port, and reapply the features.

Error Message    %FM_EARL7-4-FLOW_FEAT_FLOWMASK_REQ_FAIL: Flowmask request for the flow 
based feature [chars] for protocol [chars] is unsuccessful, hardware acceleration 
may be disabled for the feature 

Explanation    The flow mask request for the flow-based feature is unsuccessful. This condition might occur because of a TCAM resource exception, a flow mask registers resource exception, or an unresolvable flow mask conflict with other NetFlow-based features. The NetFlow shortcut installation and hardware acceleration for the feature might be disabled under this condition, and the feature might be applied in the software.

Recommended Action    Determine the NetFlow shortcut installation enable or disable status for the feature by entering the show fm fie flowmask command. If the NetFlow shortcut installation and hardware acceleration is disabled for the feature, reconfigure or unconfigure some of the other features to remove the TCAM resource exception or the flow mask conflict/flow mask resource exception condition. Reapply the feature for the flow mask request to succeed, and reenable the NetFlow shortcut installation for the feature.

Error Message    %FM_EARL7-4-MLS_FLOWMASK_CONFLICT: mls flowmask may not be honored on 
interface [chars] due to flowmask conflict 

Explanation    The configured MLS flow mask conflicts with other features or with the QoS configuration. The traffic on the specified interface will be sent to the software. NDE might not function correctly for the specified interface under this condition.

Recommended Action    Remove the conflicting configuration, and reconfigure the MLS flow mask.

Error Message    %FM_EARL7-4-MLS_FLOWMASK_NO_TCAM_RESOURCES: mls flowmask may not be 
honored on interface [chars] due to TCAM resource shortage 

Explanation    The requirements for the configured features exceed the TCAM resources. The flow mask may not be programmed in the hardware. Under this condition, the traffic on the specified interface is sent to the software. NDE may not function correctly for this interface.

Recommended Action    Redefine and reapply some of the features, or unconfigure one or more features.

Error Message    %FM_EARL7-4-MLS_IPV6_FORCED_COMPRESS_MODE: Use IPv6 mask values of 88 
or lower in forced compress mode for consistent processing of incompressible IPv6 
addresses in both hardware and software.

Explanation    IPv6 compress mode is a hardware feature. If compress mode is force-enabled and IPv6 ACLs are built with mask values 89 or greater, inconsistent behavior in IPv6 ACL processing could result with incompressible addresses. Using IPv6 mask values of 88 and lower while forcing compress mode ensures proper hardware processing of IPv6 ACL entries.

Recommended Action    Use IPv6 mask values of 88 or lower in forced compress mode for consistent processing of incompressible IPv6 addresses in both hardware and software.

Error Message    %FM_EARL7-4-NO_FLOWMASK_REGISTERS: Feature configuration on interface 
[chars] could not allocate required flowmask registers, traffic may be switched 
in software 

Explanation    The flow mask requirements for configured features on the specified interface cannot be met because there are no available flow mask registers. The traffic on this interface will be sent to software.

Recommended Action    Remove one or more NetFlow-based features or QoS Micro-flow policing from the configuration, and reapply the features.

Error Message    %FM_EARL7-4-RACL_REDUCED_MCAST_RATELIM_WARN: Enabling acl [chars] 
rate-limiter will cause Multicast traffic to be dropped in hardware on interface 
[chars] in [chars] direction 

Explanation    A TCAM resource contention prevents routed ACLs from being programmed in TCAM for the specified interface in the specified direction. All Layer 3 traffic will be sent to the CPU to have RACLs enforced in software. Due to a lack of resources, multicast special VMRs cannot be programmed. In this condition, rate limiting for traffic bridged to the CPU by the ACL is incompatible with the status of the multicast interface and will cause multicast traffic to be dropped in hardware.

Recommended Action    Do not configure the mls unicast acl {input | output} command.

Error Message    %FM_EARL7-4-VACL_PVLAN: Vacl config is NOT supported on secondary 
Vlan: [chars] and will be removed 

Explanation    The current implementation of the Feature Manager does not support the configuration of VACLs on secondary VLANs. The VACL configuration is removed from the VLAN interface once it becomes a secondary private VLAN. Both the hardware and the software will be than updated accordingly.

Recommended Action    Change the VLAN to be a primary VLAN or a regular (nonprivate) VLAN and reapply the VLAN filter.

FPM Messages

This section contains Flexible Packet Matching (FPM) messages.

FPM-4

Error Message    %FPM-4-FILEACCERR: Error opening the file [chars] 

Explanation    The specified file was not found.

Recommended Action    Ensure that the file with this name exists. If necessary, copy the file from the active supervisor engine.

FTTM Messages

This section contains Full Ternary TCAM Manager (FTTM) messages.

FTTM-3

Error Message    %FTTM-3-ERROR: [chars] 

Explanation    This message indicates a Full Ternary TCAM Manager error. The nature of the error is given in the message itself.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

HA_EM Messages

This section contains Embedded Event Manager (HA_EM) messages.

HA_EM-3

Error Message    %HA_EM-3-FMPD_CLI_NOTTY: Error attempting to access an unopened CLI 
session: [chars] 

Explanation    An error occurred while the system attempted to access the specified unopened CLI session.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

HYPERION Messages

This section contains Hyperion ASIC (HYPERION) messages.

HYPERION-3

Error Message    %HYPERION-3-FAILURE_INTR_CFG: Failure to setup the Hyperion device 
interrupts. 

Explanation    The internal ASIC on a line card could not be initialized. The device is not operational and has been disabled. The data path is not operational.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

HYPERION-4

Error Message    %HYPERION-4-HYP_RESET: Hyperion Error Interrupt. Resetting ASIC. 

Explanation    The Hyperion ASIC in the SPA or Enhanced FlexWAN module has received a fatal error. The ASIC is automatically reset, and the SPA or Enhanced FlexWAN module attempts to continue normal operation.

Recommended Action    No action is required if traffic recovers. If traffic does not recover, copy the error message exactly as it appears on the console or in the system log. Enter the show platform hardware hyperion all command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show platform hardware hyperion all output, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    %HYPERION-4-HYP_RESET: Hyperion ASIC reset, interrupt [chars] 

Explanation    The Hyperion ASIC in the SPA or Enhanced FlexWAN module has received a fatal error. The ASIC is automatically reset, and the SPA or Enhanced FlexWAN module attempts to continue normal operation.

Recommended Action    No action is required if traffic recovers. If traffic does not recover, copy the error message exactly as it appears on the console or in the system log. Enter the show platform hardware hyperion all command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show platform hardware hyperion all output, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    %HYPERION-4-UNEXPECTED_VERSION: Unexpected Hyperion version. 

Explanation    The line card is unable to recognize the version of the Hyperion ASIC.

Recommended Action    No action is required if traffic passes through the line card. If traffic does not pass through the line card, check the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/ to determine in which version this problem is fixed and upgrade accordingly. If traffic does not pass after the upgrade, contact your Cisco technical support representative.

HYPERION-5

Error Message    %HYPERION-5-BUS_MODE_CHANGE: The System Switching Bus Mode changed to 
[chars] mode 

Explanation    The system switching bus interface device mode changed switching bus modes. The mode is specified in the system message.

Recommended Action    The supervisor engine instructed the module to change the mode on the switching bus. No action is required.

Error Message    %HYPERION-5-BUS_SEQ_ERR: Constellation bus Sequence Error. Resetting 
Hyperion ASIC. 

Explanation    The switch processor has detected a sequence error on the backplane bus. A reset sequence from the EARL has been called to recover from this error. System traffic should recover and continue normally.

Recommended Action    If traffic recovers, no action is required. If traffic does not recover, copy the error message exactly as it appears on the console or in the system log. Enter the show platform hardware hyperion all command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show platform hardware hyperion all output, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    %HYPERION-5-HYP_INIT_FAILURE: The Hyperion ASIC initialization failed 

Explanation    The Hyperion ASIC initialization was not successful.

Recommended Action    The Hyperion ASIC is not operational and is disabled.

Error Message    %HYPERION-5-NULL_HYP_OBJECT: The Hyperion device object pointer is set 
to NULL 

Explanation    The memory location of the Hyperion ASIC device object is invalid.

Recommended Action    The Hyperion ASIC operation is disabled, and the device interrupt is now masked.

IDBMAN Messages

This section contains Interface Descriptor Block Manager (IDBMAN) messages.

IDBMAN-4

Error Message    %IDBMAN-4-CONFIG_WRITE_FAIL: FFailed to generate confgiruation for 
interface [chars] 

Explanation    The system failed to generate a configuration for the specified interface because of a problem with the file system. The active and standby supervisor engines will have configurations that do not match.

Recommended Action    The standby supervisor engine is reloaded automatically to recover from the problem. If the standby supervisor engine does not recover, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

IP_DEVICE_TRACKING Messages

This section contains Switch IP Host Tracking HA (IP_DEVICE_TRACKING) messages.

IP_DEVICE_TRACKING-4

Error Message    %IP_DEVICE_TRACKING_HA-4-ENTRY_OUT_OF_SYNC: Host mac-address [enet] 
ip-address [IP_address] interface [chars] 

Explanation    An inconsistency has been detected between the active supervisor engine IP device tracking table and the standby supervisor engine IP device tracking table for this host.

Recommended Action    No action is required.

Error Message    %IP_DEVICE_TRACKING-4-TABLE_LOCK_FAILED: Table already locked by 
process-id [dec]([chars]) 

Explanation    The IP device tracking table could not be updated because of another process holds a lock on the table.

Recommended Action    No action is required.

IPC Messages

This section contains InterProcessor Communication (IPC) messages.

IPC-2

Error Message    %IPC-2-INVALIDZONE: The IPC Zone is invalid. zone=[hex] 

Explanation    The zone ID entry is not in the zone table.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

IPC-5

Error Message    %IPC-5-WATERMARK:[dec] messages pending in [hex] for the port [chars] 
[hex].[hex]

Explanation    A particular IPC port is overused. An application is not draining packets quickly, which suggests that the CPU might be busy. [dec] is the number of messages pending in the IPC to be processed by the application. [chars] is the IPC port name. The first [hex] is the IPC port number, the second [hex] is the IPC seat number, and the third [hex] is the IPC index.

Recommended Action    No action is required.

IPFAST Messages

This section contains IP fast-switching (IPFAST) messages.

IPFAST-2

Error Message    %IPFAST-2-FASTPORTCREATEERR: Attempt to create [chars] failed after 
[dec] retries (last error:[chars]) 

Explanation    The line card attempted to create a port to the route processor but has failed after a few retries. This condition might result in the CEF becoming disabled on the line card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %IPFAST-2-FASTPORTOPEN: Requested to open [chars], id [int] when 
already open. Attempting to re-open. 

Explanation    The line card is attempting to open a port to the route processor when one is already open. This behavior could be transient but might result in multiple ports opened for the same purpose.

Recommended Action    The router should be able to recover from this situation. If CEF problems develop for this line card, copy the error message exactly as it appears on the console or in the system log, and contact your Cisco technical support representative.

Error Message    %IPFAST-2-FASTPORTOPENERR: Attempt to open [chars] failed after [dec] 
retries (last error:[chars]) 

Explanation    The line card attempted to open a port to the route processor but has failed after a few retries. This condition might result in the CEF becoming disabled on the line card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %IPFAST-2-FASTPORTREGISTERERR: Attempt to register [chars] failed 
after [dec] retries (last error:[chars]) 

Explanation    The line card attempted to register a port to the route processor but has failed after a few retries. This condition might result in the CEF becoming disabled on the line card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

IPFAST-4

Error Message    %IPFAST-4-FASTPORTCREATEWARN: Attempt to create [chars] failed. Will 
be retried [dec] times (last error:[chars]) 

Explanation    The line card is attempting to create a port to the route processor but has failed. This behavior could be transient. The system will reattempt to create the port.

Recommended Action    The system should be able to recover from this condition. If CEF becomes disabled on this line card, copy the error message exactly as it appears on the console or in the system log, and contact your Cisco technical support representative.

Error Message    %IPFAST-4-FASTPORTOPENWARN: Attempt to open [chars] failed. Will be 
retried [dec] times (last error:[chars]) 

Explanation    The line card is attempting to open a port to the route processor
but has failed. This behavior could be transient. The system will reattempt to create the port.

Recommended Action    The system should be able to recover from this condition. If CEF becomes disabled on this line card, copy the error message exactly as it appears on the console or in the system log, and contact your Cisco technical support representative.

IPNAT Messages

This section contains IP Network Address Translation (IPNAT) messages.

IPNAT-4

Error Message    %IPNAT-4-ADDR_ALLOC_FAILURE: Address allocation failed for 
[IP_address], pool [chars] might be exhausted 

Explanation    An address could not be allocated from the IP NAT pool. This condition can cause a translation failure and might result in packets being dropped. The counter for missed packets will be incremented.

Recommended Action    Determine if the NAT pool has been exhausted. To reuse any existing addresses in the NAT pool for new packet flows, clear the current NAT entries using the clear ip nat translation command.

IPV6 Messages

Error Message    %IPV6-3-UNFRAGMENTABLE: Cannot fragment packet: unfragmentable part 
length [dec], MTU of [dec] 

Explanation    An internal software error occurred. A single packet originated by this system could not be fragmented and has been dropped. Normal system operation continues.

Recommended Action    This is a transient error. However, this condition indicates other errors in the software that will require further examination by your Cisco technical support representative. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

IP_VRF Messages

This section contains IP VPN routing/forwarding instance common error (IP_VRF) messages.

IP_VRF-3

Error Message    %IP_VRF-3-VRF_CHKPT_TX_FAIL: [chars] 

Explanation    This message indicates a failed attempt to send a VRF table ID checkpoint message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %IP_VRF-3-VRF_CREATE_FAIL: [chars] 

Explanation    This message indicates a failure to create an IP VRF.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %IP_VRF-3-VRF_TABLEID_INCONSISTENT: [chars] 

Explanation    The VRF table ID is inconsistent between two RPs.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

IP_VRF-4

Error Message    %IP_VRF-4-VRF_DELETE_WAIT: The VRF [chars] is getting deleted after a 
wait 

Explanation    There are still routes in the deleted VRF routing table. To ensure reusablity of the same VRF, the system forcibly clears the routes in the VRF routing table, which causes the VRF to be deleted.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

IXP_MAP Messages

This section contains ESF Network Processor Client Mapper (IXP_MAP) messages.

IXP_MAP-3

Error Message    %IXP_MAP-3-QOS_CONFIG: [chars] error detected: [chars] [chars] [hex] 
[hex] 

Explanation    A configuration error for the QoS ESF Network Processor Client Mapper was detected. This configuration error is not considered fatal to the operation of the ESF Network Processors. The software is designed to detect and report the error condition.

Recommended Action    Change the configuration to correct the QoS ACL configuration problem. If the condition persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs

KEYMAN Messages

This section contains key string encryption (KEYMAN) messages.

KEYMAN-4

Error Message    %KEYMAN-4-KEYSTR_BAD_CRYPTO: Bad encrypted keystring for key id [dec]. 

Explanation    The system could not successfully decrypt an encrypted key string. The key string may have been corrupted during system configuration.

Recommended Action    Reenter the key string command, and reconfigure the key string.

Error Message    %KEYMAN-4-KEYSTR_CRYPTO_TYPE: Type [dec] encryption unknown. 
Interpreting keystring as literal 

Explanation    The system does not recognize the format type. A key string format type value of 0 (unencrypted key string) or 7 (hidden key string), followed by a space, can precede the actual key string to indicate its format. An unknown type value will be accepted, but the system will consider the key string as being unencrypted.

Recommended Action    Use the correct format for the value type or remove the space following the value type.

L2 Messages

This section contains Layer 2 (L2) messages

Error Message    %L2-3-DUP_REG: L2 Forwarding Engine: [chars] Attempt to program 
duplicate MAC address 

Explanation    There was an attempt to program a duplicate MAC address in the match registers. [chars] indicates the source of the attempt.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

L2_AGING Messages

This section contains Layer 2 aging (L2_AGING) messages.

L2_AGING-2

Error Message    %L2_AGING-2-DEC_EN_FAIL: Failed to initialize Distributed EtherChannel 

Explanation    One or more resources that are required for the Distributed EtherChannel operation are in use.

Recommended Action    Remove the monitor session reserved for service modules by entering the no monitor session service module command, and then try to reinitialize the operation.

Error Message    %L2_AGING-2-SIG_INST_FAIL: [chars]: Failed to install signal handler 

Explanation    A signal handler could not be installed for a process that involves Layer 2 aging.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

L2_APPL Messages

This section contains Layer 2 application (L2_APPL) messages.

L2_APPL-0

Error Message    %L2_APPL-0-TASK_SPAWN_FAIL: Failed to spawn task "[chars]"

Explanation    The specified initializing task failed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

L2_APPL-4

Error Message    %L2_APPL-4-MAC_MOVE: Host [enet] is flapping between port [chars] and 
port [chars] 

Explanation    A host is going up and down between ports.

Recommended Action    Examine the network for possible loops.

Error Message    %L2_APPL-4-MAC_USAGE: MAC usage is currently [dec]% 

Explanation    MAC usage is exceeded for the Layer 2 monitoring feature.

Recommended Action    No action is required.

Error Message    %L2_APPL-4-UNKMESG: Unknown received message [dec] 

Explanation    An internal error occurred. There might be a mismatch between image versions.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

L3MM Messages

This section contains Layer 3 Mobility Manager (L3MM) messages.

L3MM-4

Error Message    %L3MM-4-AP_DB_ADD: Failed to add AP to DB { AP: [enet], [IP_address]} 

Explanation    The L3MM failed to add the entry for the specified AP into the AP database.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %L3MM-4-AP_DB_DEL: Failed to delete AP from DB { AP: [enet], 
[IP_address]} 

Explanation    The L3MM failed to delete the entry for the specified AP from the AP database.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %L3MM-4-DUP_AP_IPADDR: AP [enet] is requesting ip [IP_address] which 
is being used by another AP 

Explanation    The L3MM detected that an AP requested an IP address that is being used by another AP in the network.

Recommended Action    Change the IP address of one of the two APs.

Error Message    %L3MM-4-DUP_IPADDR: MN [enet] is requesting ip [IP_address] which is 
being used by MN [enet] 

Explanation    The L3MM detected that a MN requested an IP address that is being used by another MN in the network.

Recommended Action    Change the IP address of one of the two MNs.

Error Message    %L3MM-4-INIT_FAIL: Initialization failure; reason: [chars] 

Explanation    The L3MM failed to initialize due to the specified reason.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %L3MM-4-MALLOC_FAIL: Memory allocation failure [chars] 

Explanation    The L3MM failed to allocate memory that was needed to perform an operation or to respond to an event.

Recommended Action    Increase the memory on the RP of the supervisor engine.

Error Message    %L3MM-4-MN_IPDB_ADD: Failed to add MN to MN DB { MN: [enet], 
[IP_address]} 

Explanation    The L3MM failed to add the entry for the specified MN into the MN IP database.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %L3MM-4-MN_IPDB_DEL: Failed to delete MN from IP DB { MN: [enet], 
[IP_address]} 

Explanation    The L3MM failed to delete the entry for the specified MN from the MN IP database.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %L3MM-4-MN_MACDB_ADD: Failed to add MN to MAC DB { MN: [enet], AP: 
[IP_address] } 

Explanation    The L3MM failed to add the entry for the specified MN into the MN MAC database.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %L3MM-4-MN_MACDB_DEL: Failed to delete MN from MAC DB { MN: [enet], 
[IP_address], AP: [IP_address], WNID: [dec] } 

Explanation    The L3MM failed to delete the entry for the specified MN from the MN MAC database.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

L3MM-5

Error Message    %L3MM-5-WLAN: Wireless LAN Module in slot [dec] is [chars] 

Explanation    The L3MM detected a change in the state of the Wireless LAN module in the specified slot. If the module is now on line, the L3MM starts accepting access-point and mobile-node registrations from the WDS on the module. If the module is now off line, the L3MM purges all APs and MNs received from the module.

Recommended Action    No action is required.

Error Message    %L3MM-5-WLAN_COMM_ABORT: Communication with Wireless LAN Module in 
slot [dec] aborted ([chars]) 

Explanation    The L3MM detected a communication failure with the wireless LAN module specified in the error message above. The L3MM will respond by purging its AP and MN databases as if the module went offline. However, the module will not be reset by the L3MM.

Recommended Action    No action is required.

Error Message    %L3MM-5-WLAN_PWR_DN: Wireless LAN Module in slot [dec] will be powered 
down, another module is already active 

Explanation    The L3MM detected a Wireless LAN module trying to come online, while another module was already functional as the active Wireless LAN module. The L3MM does not support more than one Wireless LAN module on line in the chassis at a given time, which is why this module will be powered down.

Recommended Action    No action is required.

LINK Messages

This section contains data link (LINK) messages.

LINK-6

Error Message    %LINK-6-BERTMSGS: [chars] 

Explanation    This message displays bit error-rate (BERT) information messages.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

MAC_LIMIT Messages

This section contains MAC limit feature (MAC_LIMIT) messages.

MAC_LIMIT-4

Error Message    %MAC_LIMIT-4-DROP: Vlan [dec] with Configured limit = [dec] has 
currently [dec] Entries 

Explanation    The number of entries for a VLAN has gone below or is equal to the allowed number.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MAC_LIMIT-4-ENFORCE: Enforcing limit on Vlan [dec] with Configured 
limit = [dec] 

Explanation    The number of entries for a VLAN has exceeded the allowed number. The action that enforces the limit is configured.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MAC_LIMIT-4-EXCEED: Vlan [dec] with Configured limit = [dec] has 
currently [dec] Entries 

Explanation    The number of entries for a VLAN has exceeded the allowed number.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MAC_LIMIT-4-PORT_DROP: [chars] with Configured limit [dec] has 
currently [dec] entries 

Explanation    The number of entries for the specified port has gone below or is equal to the permitted number.

Recommended Action    This message is for reporting purposes only.

Error Message    %MAC_LIMIT-4-PORT_ENFORCE: Enforcing limit on [chars] with Configured 
limit [dec] 

Explanation    The number of entries for the specified port has exceeded the permitted number. The action to enforce the limit is configured.

Recommended Action    This message is for reporting purposes only.

Error Message    %MAC_LIMIT-4-PORT_EXCEED: [chars] with configured limit [dec] has 
currently [dec] entries 

Explanation    The number of entries for the specified port has exceeded the permitted number.

Recommended Action    This message is for reporting purposes only.

Error Message    %MAC_LIMIT-4-VLAN_DROP: Vlan [dec] with configured limit [dec] has 
currently [dec] entries 

Explanation    The number of entries for the specified VLAN has gone below or is equal to the permitted number.

Recommended Action    This message is for reporting purposes only.

Error Message    %MAC_LIMIT-4-VLAN_ENFORCE: Enforcing limit on Vlan [dec] with 
configured limit [dec] 

Explanation    The number of entries for the specified VLAN has exceeded the permitted number. The action to enforce the limit is configured.

Recommended Action    This message is for reporting purposes only.

Error Message    %MAC_LIMIT-4-VLAN_EXCEED: Vlan [dec] with configured limit [dec] has 
currently [dec] entries 

Explanation    The number of entries for the specified VLAN has exceeded the permitted number.

Recommended Action    This message is for reporting purposes only.

MAC_MOVE

This section contains MAC move notification feature (MAC_MOVE) messages.

MAC_MOVE-4

Error Message    %MAC_MOVE-4-NOTIF: Host [enet] in vlan [dec] is flapping between port 
[chars] and port [chars] 

Explanation    The system found the specified host moving between the specified ports.

Recommended Action    Examine the network for possible loops.

MCAST Messages

This section contains Layer 2 Multicast log (MCAST) messages.

MCAST-6

Error Message    %MCAST-6-ETRACK_LIMIT_EXCEEDED: [chars] snooping was trying to 
allocate more explicit-tracking entries than what allowed ([dec]

Explanation    The allocation of explicit-tracking entries is limited so that IGMP and MLD snooping are prevented from consuming too many system resources.

Recommended Action    Reduce the number of (s,g) channels or the number of receivers. When the explicit-tracking database has gone beyond its limit, new membership for any channels will not be tracked. This condition might cause high-leave latency when those members leave a channel. Another alternative is to increase the limit from configuration mode by entering the ip igmp snooping limit track max-entries command. It is important to note that increasing the value of max-entries could cause the system to fail because of high use of system resources.

Error Message    %MCAST-6-GC_LIMIT_EXCEEDED: IGMP snooping was trying to allocate more 
Layer 2 entries than what allowed ([dec])

Explanation    IGMP snooping attempted to allocate more Layer 2 entries than the permitted amount specified in the message.

Recommended Action    No action is required.

Error Message    %MCAST-6-IGMP_CGMP_MODE: IGMP snooping now is running in IGMP_CGMP 
mode on vlan [dec]

Explanation    The specified VLAN is running in IGMP/CGMP mode.

Recommended Action    No action is required.

Error Message    %MCAST-6-IGMP_ONLY_MODE: IGMP snooping now is running in IGMP_ONLY 
mode on vlan [dec]

Explanation    The specified VLAN is running in IGMP mode.

Recommended Action    No action is required.

Error Message    %MCAST-6-IGMP_PKT_DROPPED: IGMP: IGMP Queue full (high packet rate/CPU 
busy), dropped [dec] packet(s) in last 5 minutes

Explanation    The IGMP packet queue is not able to accommodate additional packets. Any additional packets will be dropped without processing.

Recommended Action    Reduce the IGMP packet rate to prevent packets from being dropped.

Error Message    %MCAST-6-IGMP_RATE_LIMIT_DISABLE: IGMP: enabling Snooping on 
Vlan([dec]), IGMP messages will not be rate limited 

Explanation    After throttling the IGMP messages on the VLAN for a certain period, snooping is reenabled after the user manually fixes the rate on the offending VLAN and reduces the CPU load.

Recommended Action    No action is required.

Error Message    %MCAST-6-IGMP_RATE_LIMIT_ENABLE: IGMP: Incoming IGMP message rate 
exceeded max threshold([dec] pps), disabling Snooping on Vlan([dec]) with 
Rate([dec] pps) 

Explanation    The incoming rate of IGMP messages exceeded the maximum configured threshold. Snooping will be disabled on all high-rate VLANs to lower the aggregate rate below the threshold on all remaining VLANs.

Recommended Action    Ease the CPU load by reducing the rate of IGMP messages on all high-rate VLANs.

Error Message    %MCAST-6-L2_HASH_BUCKET_COLLISION: Failure installing (G,C)->index: 
([enet],[dec])->[hex] Protocol :[dec] Error:[dec] 

Explanation    A Layer 2 entry could not be installed in the hardware because there is not enough space in the hash bucket. Multicast packets will be flooded on the incoming VLAN because the Layer 2 entry installation failed.

Recommended Action    No action is required.

MCAST_MQC Messages

This section contains Multicast Modular Quality of Service (MCAST_MQC) command-line interface messages.

Error Message    %MCAST_MQC-3-CMAP_SDB_REGISTER: Error initialising class-map of type 
multicast-flows. 

Explanation    The system could not register the component related to the class map of type \n multicast flows to the string database.

Recommended Action    No action is necessary. This message is for informational purposes only.

MDT Messages

This section contains Multicast Distribution Tree (MDT) messages.

MDT-4

Error Message    %MDT-4-NO_GROUP_LINK: MDT entry [chars]:([IP_address],[IP_address]) 
linked by source but not linked by group

Explanation    The entry for the affected MDT group was not properly linked into the MDT database. The inconsistency has been repaired. [chars] is the MDT entry and the [IP_address],[IP_address] are the linked IP addresses.

Recommended Action    No action is required.

Error Message    %MDT-4-RD_CONFLICT: MDT entry [chars]:([IP_address],[IP_address]) 
received an update for RD [chars]

Explanation    A previously existing MDT entry should have been withdrawn by BGP before sending this conflicting update. [chars] is the MDT entry, the [IP_address],[IP_address] are the linked IP addresses, and the second [chars] is the redirect name.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter at https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

MFIB_CONST_RP Messages

This section contains Multicast Forwarding Information Base route processor (MFIB_CONST_RP) messages.

MFIB_CONST_RP-6

Error Message    %MFIB_CONST_RP-6-REPLICATION_MODE_CHANGE: Replication Mode Change 
Detected. Current system replication mode is [chars] 

Explanation    When automatic detection of the replication mode is enabled, the system will transition to ingress mode when an egress-incapable line card is inserted. The system will transition back to egress mode when the last egress-incapable line card is removed. The transition between ingress and egress modes will cause temporary loss of traffic,

Recommended Action    To prevent traffic loss, enter the ipv6 mfib hardware-switching replication-mode ingress command.

MISTRAL Messages

This section contains Mistral ASIC (MISTRAL) messages.

MISTRAL-3

Error Message    %MISTRAL-3-BAD_PAK: Possibly un-encapsulated packet passed to Mistral: 
int [chars] type [int] stat [hex] flags [hex] size [dec] encsize [dec] offset [dec] 
requeue_token [int] r1 [int] r2 [int] total detected [int] 

Explanation    A badly encapsulated packet from the process level was passed to the Mistral ASIC.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MISTRAL-3-NOEOBCBUF: No EOBC buffer available. Dropping the packet. 

Explanation    The Ethernet out-of-band channel pool of receive buffers for the Mistral ASIC has been exhausted. No additional input packets can be handled until some buffers are returned to the pool.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

MLS_ACL_COMMON

This section contains Multilayer Switching ACL (MLS_ACL_COMMON) messages.

MLS_ACL_COMMON-3

Error Message    %MLS_ACL_COMMON-3-MLS_ACL_CONSIST_FIX: ACL TCAM inconsistency seen at 
index [dec] and could not be fixed 

Explanation    The ACL TCAM inconsistency checker found an inconsistency between software and hardware TCAM entries and could not fix it . [dec] is the index where the inconsistency was found.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

MLS_ACL_COMMON-4

Error Message    %MLS_ACL_COMMON-4-LOG_UPDATE_NO_RL: ACL TCAM update ([chars] 
direction) occured on interface [chars]; [chars] action taken [chars] msec 

Explanation    An update of the ACL TCAM occurred on the specified interface. When the ACL TCAM is updated, the specified security action is taken for the specified time interval.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MLS_ACL_COMMON-4-LOG_UPDATE_RL: ACL TCAM update ([chars] direction) 
occured on interface [chars]; [chars] action taken [chars] msec 

Explanation    An update of the ACL TCAM occurred on the specified interface. When the ACL TCAM is updated, the specified security action is taken for the specified time interval.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MLS_ACL_COMMON-4-MLS_ACL_CONSIST: ACL TCAM inconsistency seen at 
index [dec]

Explanation    The ACL TCAM inconsistency checker found an inconsistency between software and hardware TCAM entries and has fixed it . [dec] is the index where the inconsistency was found.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

MLSCEF Messages

This section contains Multilayer Switching Cisco Express Forwarding (MLSCEF) messages.

MLSCEF-2

Error Message    %MLSCEF-2-EXCESSIVE_FIB_SSRAM_ERRORS: Too many fib ecc error 
interrupts. 

Explanation    The number of error interruptions exceeded the threshold. As a result of this condition, the system will fail.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MLSCEF-2-FIB_SSRAM_WRITE_INCONSISTENCY: FIB SSRAM Mismatch for Index: 
[dec] Expected: [hex], Hardware: [hex]

Explanation    A problem occurred when the system attempted to write the FIB SSRAM.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MLSCEF-2-FIB_TCAM_WRITE_INCONSISTENCY: FIB TCAM Mismatch for [chars]: 
Index: [dec]
Expected: Entry: [hex]-[hex]-[hex]
Hardware: Entry: [hex]-[hex]-[hex]

Explanation    A problem occurred when the system attempted to write the specified FIB TCAM entry. The specific entry could be bad.

Recommended Action    Collect the output of the show mls cef hardware and show mls cef log and show ver commands. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MLSCEF-2-RELOAD: maximum routes config mismatch. Reloading with 
correct config

Explanation    The system detected a mismatch between the user configuration route allocation and the current route allocation. A system reload is required to correct this condition.

Recommended Action    If this message appears continuously on the same module and the mls cef maximum-routes command has not been entered, copy the error message exactly as it appears on the console or in the system log. Enter the show tech-support command. Contact your Cisco technical support representative, and provide the representative with the gathered information. If the message does not appear continuously and the mls cef maximum-routes command has been entered, no action is required.

Error Message    %MLSCEF-2-SANITY_FAIL: Sanity Check of MLS FIB s/w structures failed 

Explanation    The verification process encountered inconsistent MLS FIB data structures.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MLSCEF-2-UNCORRECTABLE_SSRAM_ERROR: Bank [dec] Index: [dec], 
Expected: [hex], Hardware: [hex]. Affected TCAM [hex]-[hex]-[hex]

Explanation    This message indicates a faulty FIB SSRAM location.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

MLSCEF-7

Error Message    %MLSCEF-7-FIB_MASK_MISMATCH: Attempt to delete an entry not matching 
block mask - class = [dec], [dec]/[dec], mask [dec]/[dec]

Explanation    The passed mask does not match the stored block mask.

Recommended Action    This is a debug message only. No action is required.

MLSM Messages

This section contains Multicast Distributed Shortcut Switching (MDSS)/multilayer switching for multicast (MLSM) messages.

MLSM-6

Error Message    %MLSM-6-MLSM_PMS: MMLS: MLSM is suspending the caller process [chars] 

Explanation    MLSM is suspending the caller process. This message appears when the MLSM routines are called from the PIM/Mwheel context and MLSM routines suspend a process. When MLSM suspends the caller process, data corruption might occur for the data that is handled by the caller process.

Recommended Action    This message is informational.

Error Message    %MLSM-6-MMLS_EGRESS_INFO: MMLS: Please make sure no multicast traffic 
is going through egress incapable line cards when system is operating in egress 
mode 

Explanation    There should be no multicast traffic going through egress-incapable line cards while the system is operating in egress replication mode.

Recommended Action    Determine if there are any egress-incapable line cards in the system. If there are egress-incapable line cards, verify that there is no multicast traffic going through them.

Error Message    %MLSM-6-MMLS_LEGACY_INSERTED: MMLS: Legacy Linecard Inserted, Egress 
Replication Mode will be disabled 

Explanation    Egress replication is not supported with legacy modules. The system will transition to ingress mode and will cause a temporary loss of traffic.

Recommended Action    If the system is required to operate in egress replication mode, remove the legacy module.

Error Message    %MLSM-6-MMLS_MODE_CHANGE: MMLS: Replication Mode Change Detected 

Explanation    When automatic detection of the replication mode is enabled, the system will transition to ingress mode when an egress-incapable module is inserted. The system will transition back to egress mode when the last egress-incapable module is removed.

Recommended Action    Transitioning between ingress and egress mode causes a temporary loss of traffic. To prevent this temporary loss of traffic, enter the mls ip replication-mode ingress command.

Error Message    %MLSM-6-MMLS_NO_EGRESS_LOCAL_IN_INGRESS: MMLS: Egress Local feature is 
NOT applicable in Ingress mode 

Explanation    When the system transitions from egress replication mode to ingress mode, the egress local feature will not be applied, even if the egress local feature is enabled.

Recommended Action    If the egress local feature is required, restore the system replication mode to egress.

MLS_RATE Messages

This section contains Multilayer Switching Rate Limit (MLS_RATE) messages.

MLS_RATE-4

Error Message    %MLS_RATE-4-CPP_DISABLED_IN_HW: Control Plane Policing NOT performed 
in hardware, due to the presence of egress QoS. 

Explanation    CPP cannot be performed in the hardware when the system is running in PFC3A mode and egress QoS is configured on any other interface. Under these circumstances, CPP is performed only in the software until egress QoS is removed from the running configuration.

Recommended Action    Remove any egress QoS from the running configuration, or upgrade to a PFC3B or PFC3-BXL. We strongly recommend the upgrade.

Error Message    %MLS_RATE-4-CPP_RE_ENABLED_IN_HW: Control Plane Policing will now be 
performed in hardware. 

Explanation    CPP cannot be performed in the hardware when the system is running in PFC3A mode and egress QoS is configured on any other interface. Egress QoS has been removed from the running configuration.

Recommended Action    Because egress QoS has been removed, no action is required. To prevent this condition from occurring again, we strongly recommend that you upgrade to a PFC3B or PFC3BXL.

Error Message    %MLS_RATE-4-DISABLING: The Layer2 Rate Limiters have been disabled.

Explanation    This feature is turned off with the current hardware configuration. The Layer 2 rate limiters are not supported with this combination of modules.

Recommended Action    Refer to the feature usage guidelines for more details.

Error Message    %MLS_RATE-4-LIMITING_DOWN: MLS HARDWARE RATE-LIMITING functionality is 
not active 

Explanation    There are not enough memory resources to support the rate limiting functionality.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MLS_RATE-4-NO_RESOURCE: The hardware Rate Limiters are fully used 

Explanation    There are no more hardware rate limiters available.

Recommended Action    EARL supports a limited number of hardware rate limiters. All may be used. To display the features that use these hardware rate limiters, enter the show mls rate-limit usage command. To program a rate limiter for the new feature, unconfigure one of the configured rate limiters.

Error Message    %MLS_RATE-4-NOT_SUPPORTED: This functionality is not configurable. 

Explanation    The rate limit functionality is not active with the current hardware configuration.

Recommended Action    Refer to the feature usage guidelines for more details.

Error Message    %MLS_RATE-4-OVERWRITING_VALUE: Overwriting the rate value for: [chars] 
case 

Explanation    Some rate limiters share the same hardware register. This message is printed if programming a new rate limiter causes a previously configured one to be overwritten.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

MLS_STAT Messages

This section contains Multilayer Switching Statistics (MLS_STAT) messages.

MLS_STAT-4

Error Message    %MLS_STAT-4-IP_CSUM_ERR: IP checksum errors

Explanation    Packets with IP checksum errors have been received.

Recommended Action    No action is necessary. This message is for informational purposes only.

Error Message    %MLS_STAT-4-IP_LEN_ERR: MAC/IP length inconsistencies

Explanation    Packets with an IP length that does not match their physical length have been received.

Recommended Action    No action is necessary. This message is for informational purposes only.

Error Message    %MLS_STAT-4-IP_TOO_SHRT: Too short IP packets received

Explanation    Packets with IP minimum length check errors have been received.

Recommended Action    No action is necessary. This message is for informational purposes only.

Error Message    %MLS_STAT-4-IPX_LEN_ERR: MAC/IPX length inconsistencies

Explanation    Packets with an IPX length that does not match their physical length have been received.

Recommended Action    No action is necessary. This message is for informational purposes only.

Error Message    %MLS_STAT-4-IPX_TOO_SHRT: Too short IPX packets received

Explanation    Packets with IPX minimum length check errors have been received.

Recommended Action    No action is necessary. This message is for informational purposes only.

MMLS Messages

This section Multicast Multilayer Switching (MMLS) messages.

MMLS-6

Error Message    %MMLS-6-ADJ_ALLOC_FAILURE: Failed to allocate Adjacency for the 
multicast flow ([IP_address], [IP_address])

Explanation    The system is unable to allocate an adjacency for the specified flow. The system will attempt the specified flow again. The flow is software switched until it is successfully installed in the hardware. The adjacency table utilization could be very high and might need to be brought down.

Recommended Action    Determine adjacency table utilization. Try removing some hardware-switched flows.

Error Message    %MMLS-6-BIDIR_ADJ_LIMIT_EXCEEDED: Failed to allocate Adjacency for 
Bidir Multicast shortcuts, exceeded limit of ([dec]), subsequent flows will be 
software switched.

Explanation    The system limit of maximum adjacencies for bidirectional shortcuts is exceeded. As a result, any new multicast flows will be switched by the software.

Recommended Action    The number of bidirectional multicast flows is too large to fit in the hardware. There is no workaround.

Error Message    %MMLS-6-FIB_LIMIT_EXCEEDED: Failed to allocate FIB entry, exceeded 
system limit of ([dec]) entries. 

Explanation    The maximum FIB entry limit has been exceeded. FIB entries cannot be allocated by MMLS.

Recommended Action    The total number of multicast shortcuts is too large to fit in the FIB table. Subsequent shortcuts will be switched by the software. There is no workaround.

Error Message    %MMLS-6-MET_LIMIT_EXCEEDED: Failed to allocate MET entry, exceeded 
system limit of ([dec]) entries. Number of times MET limit is exceeded in the last 
1 min : [dec] 

Explanation    The maximum MET entry limit has been exceeded. MET entries cannot be allocated by MMLS.

Recommended Action    The total number of OIFs is too large to fit in the MET table. Subsequent shortcuts or OIFs will be switched by the software. There is no workaround.

Error Message    %MMLS-6-MMLS_EGRESS_INCAPABLE_LC_INSERTED: MMLS: Egress incapable 
line card ([dec]) inserted in forced egress replication mode 

Explanation    An egress-incapable line card was inserted while the system is operating in forced egress replication mode. No multicast traffic can be sourced from this egress-incapable line card.

Recommended Action    Verify that there is no multicast traffic going through this egress-incapable line card.

Error Message    %MMLS-6-MMLS_EGRESS_INCAPABLE_LC_PRESENT: MMLS: Egress incapable line 
card present while forcing replication mode to egress 

Explanation    There is at least one line card that is egress incapable in the system, but forced egress replication mode is configured on the system. Multicast traffic must not be sourced on the egress-incapable line card.

Recommended Action    Verify that there is no multicast traffic going through this egress-incapable line card.

Error Message    %MMLS-6-MMLS_LEGACY_LC_PRESENT: MMLS: Legacy line card present, system 
cannot operate in egress replication mode 

Explanation    There is at least one legacy line card in the system. Because this legacy line card is present, the system cannot operate in egress replication mode if egress replication mode is configured.

Recommended Action    Remove the legacy line card if you want the system to operate in forced egress replication mode.

Error Message    %MMLS-6-RPF_ADJ_LIMIT_EXCEEDED: Failed to allocate Adjacency for 
multicast shortcuts with RPF-vlan: ([dec]), exceeded limit of ([dec]), subsequent 
flows will be software switched 

Explanation    The maximum number of adjacencies for multicast shortcuts with the same RPF has exceeded the system limit. Any new multicast flows will be switched by the software.

Recommended Action    The number of multicast flows with the same RPF interface is too large to fit in the hardware. There is no workaround.

Error Message    %MMLS-6-RP_LIMIT_EXCEEDED: Failed to allocate DF index for Bidir-RP, 
exceeded limit of ([dec]) RPs for VPN: ([dec]). Shortcuts for RP: ([IP_address]) 
will be software switched.

Explanation    The system limit of four route processors per VPN has been exceeded. Multicast flows for the groups served by this RP will be switched by the software.

Recommended Action    The configured RPs are too large to fit in the DF table for one VPN. Attempt to configure the groups among existing RPs in the hardware, or configure the RP in another VPN.

Error Message    %MMLS-6-VLAN_ADD_FAILURE_ON_MET_FULL: Error adding vlan [dec] to the 
MET table of some shortcuts 

Explanation    The MET is full. The system is unable to add the specified VLAN to some shortcuts. The affected shortcuts will not switch traffic for that VLAN.

Recommended Action    The MET utilization is very high and needs to be brought down by removing some VLANs or switching to ingress replication mode.

MMLS_RATE Messages

This section contains Multicast Multilayer Switching Rate Limiting (MMLS_RATE) messages.

MMLS_RATE-3

Error Message    %MMLS_RATE-3-MMLS_PARTIAL_SC_ERROR: Error installing Multicast 
Partial-sc rate-limiter.Operation failed. 

Explanation    The multicast partial-sc rate limiter could not be configured because of an error that was returned from the switch processor.

Recommended Action    The LTL index for the partial-sc rate limiter might not have initialized yet. Wait several minutes, and try to configure the rate limiter again.

MRIB_PROXY Messages

This section contains Multicast Routing Information Base proxy (MRIB_PROXY) messages.

MRIB_PROXY-2

Error Message    %MRIB_PROXY-2-MRIB_LC_CREPRC_FAILED: LC in slot [dec] failed to create 
a required process. 

Explanation    The line card could not create a process to perform delayed IPC initialization. The MFIB will not be started on this line card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %MRIB_PROXY-2-MRIB_LC_FETCH_FAIL: LC in slot [dec] failed to send an 
RPC fetch request to the RP: [chars] 

Explanation    The line card attempted to read multicast route updates from the route processor, but the RPC request failed. The line card MFIB state might now be inconsistent or frozen.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

MROUTE Messages

This section contains MROUTE messages.

MROUTE-3

Error Message    %MROUTE-3-IGMP_NOT_FOUND: IGMP group [IP address] to delete from 
interface [chars] not found in VRF [chars] 

Explanation    The group to be deleted from the interface could not be found in the IGMP cache for the VRF. [IP address] is the IP address in the IGMP group, the first [chars] is the interface, and the second [chars] is the VRF.

Recommended Action    An inconsistency in maintaining the IGMP cache occurred. Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

MSFC2 Messages

This section contains Multilayer Switch Feature Card 2 (MSFC2) messages.

MSFC2-3

Error Message    %MSFC2-3-IDB_INCORRECT_UNTHROTTLE_VECTOR: attempting to throttle idb 
[hex] ([chars]) with enable vector [hex] 

Explanation    This message indicates the presence of an invalid interface enable vector.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

NBAR Messages

This section contains network-based application recognition (NBAR) messages.

NBAR-4

Error Message    %NBAR-4-COMPILE_FAILED: Compile failed on pattern number [dec] - 
states [dec] - [chars] 

Explanation    Space for the specified regular expression cannot be allocated due to memory limitations.

Recommended Action    Perform one or more of the following actions to remedy the problem:
· Disable some features.
· Apply filtering to decrease the size of system data structures (the routing table, for example).
· In general, reduce other system activities to ease memory demands.
· If conditions warrant, upgrade to a larger memory configuration.

NETFLOW_AGGREGATION Messages

This section contains NetFlow Aggregation (NETFLOW_AGGREGATION) messages.

NETFLOW_AGGREGATION-3

Error Message    %NETFLOW_AGGREGATION-3-FLOWMASK_CONFLICT: Netflow [chars] cannot set 
the required flowmask 

Explanation    The NetFlow aggregation flow mask conflicts with other features.

Recommended Action    If NetFlow Data Export is configured, increase the size of the NDE flow mask to VLAN full flow by entering the mls flow ip interface-full command, and then reconfigure the NetFlow aggregation scheme. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

NETFLOW_AGGREGATION-4

Error Message    %NETFLOW_AGGREGATION-4-NO_TOS_AGGR: Disable hardware switching to 
enable [chars] 

Explanation    NetFlow does not currently support ToS-based aggregation schemes for hardware-switched flows.

Recommended Action    If ToS-based aggregation is required, disable hardware switching.

NETWORK_RF_API Messages

This section contains network redundancy feature API (NETWORK_RF_API) messages.

NETWORK_RF_API-3

Error Message    %NETWORK_RF_API-3-FAILDECODEDATADESCINSTDBY: Cannot decode data 
descriptor in Standby for [chars], descriptor type=[dec] 

Explanation    An internal data descriptor could not be decoded by the standby device. This message identifies the interface or controller that caused the decoding failure in the standby device. This interface was encoded in the active device but could not be decoded in the standby device. This failure probably occurred because of a software error.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %NETWORK_RF_API-3-IPC: [chars] [chars] 

Explanation    An IPC error occurred. Additional details on the nature of the error are specified in the message text on the console or in the system log.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

OIR Messages

This section contains online insertion and removal (OIR) messages.

OIR-3

Error Message    %OIR-3-SOFT_RESET: Module [dec] is being soft reset as a part of 
swichover error recovery 

Explanation    The module specified in the error message is being soft reset as a part of switchover error recovery.

Recommended Action    No action is required.

Error Message    %OIR-3-STDBY_PWRCYCLE: Standby was notified, Card in module [dec] is 
being power-cycled [chars] 

Explanation    The OIR facility on the redundant supervisor engine was notified that a module on the active supervisor engine is unresponsive. The module is being power-cycled.

Recommended Action    No action is required.

Error Message    %OIR-3-STDBY_UNKNOWN: Standby was notified, Unknown card in slot [dec] 

Explanation    The OIR facility on the redundant supervisor engine was notified that an undetermined module was detected on the active supervisor engine.

Recommended Action    Reseat the module in the specified slot.

OIR-4

Error Message    %OIR-4-WARN: [chars] 

Explanation    The OIR facility detected the specified condition.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

OIR-6

Error Message    %OIR-6-DIAG_OFFLINE: Card inserted in slot [dec], is now ready for 
offline diagnostics 

Explanation    The OIR facility detected a newly inserted module. The user configured the module to be in offline-diagnostic state. This state can be entered only after module is in online-diagnostic state.

Recommended Action    No action is required.

Error Message    %OIR-6-DIAG_ONLINE: Card inserted in slot [dec], is now ready for 
online diagnostics 

Explanation    The OIR facility detected a newly inserted module. The user configured the module to be in online-diagnostic state. The module is ready for online diagnostics if a diagnostic failure is detected during startup.

Recommended Action    No action is required.

Error Message    %OIR-6-DOWNGRADE: Fabric capable module [dec] not at an appropriate 
hardware revision level, and can only run in flowthrough mode 

Explanation    The specified fabric-capable module is not at an appropriate hardware revision level and can only run in flow through (bus) mode.

Recommended Action    Upgrade the module hardware.

Error Message    %OIR-6-DOWNGRADE_EARL: Module [dec] DFC installed is not identical to 
system DFC and will perform at current system operating mode.

Explanation    The DFC module is at a higher hardware version than the level of the system DFC. The DFC module will operate at the same level as that of the system DFC.

Recommended Action    No action is required.

Error Message    %OIR-6-INSFAN: Fan [dec] inserted 

Explanation    The OIR facility detected a newly inserted fan tray.

Recommended Action    No action is required. The system is working properly.

Error Message    %OIR-6-INSPS: Power supply inserted in slot [dec] 

Explanation    The OIR facility detected the insertion of a power supply. When powered up, the total power will be adjusted.

Recommended Action    No action is required. The system is working properly.

Error Message    %OIR-6-PWRFAILURE: Module [dec] is being disabled due to power 
convertor failure [hex] 

Explanation    The DC-DC power convertor failed on the specified module. Replace the failed hardware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OIR-6-REMFAN: Fan [dec] removed 

Explanation    The OIR facility detected the removal of a fan tray.

Recommended Action    No action is required.

Error Message    %OIR-6-SEQ_MISMATCH: SCP seq mismatch for card in slot [dec] : [chars] 

Explanation    The OIR facility detected an SCP sequence mismatch for the module in the specified slot.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OIR-6-STDBY_INSCARD: Standby was notified, card online in slot [dec] 

Explanation    The OIR facility on the redundant supervisor engine was notified by the active supervisor engine that a processor was inserted in the specified slot. All interfaces are usable now.

Recommended Action    No action is required.

Error Message    %OIR-6-STDBY_REMCARD: Standby was notified, card removed from slot 
[dec] 

Explanation    The OIR facility on the redundant supervisor engine was notified by the active supervisor engine that a processor in the specified slot was removed.

Recommended Action    No action is required.

ONLINE Messages

This section contains download processor (ONLINE) messages.

ONLINE-6

Error Message    %ONLINE-6-INVALID_DNLD_REQ: Received an unexpected image download 
request from Linecard Module [dec], Proc [dec]. Linecard image download request 
reason was [chars] 

Explanation    The system received an image download request from the module and processor complex specified in the message text, but the complex has already downloaded the image and should be initialized and operating normally.

Recommended Action    No action is required.

Error Message    %ONLINE-6-LCP_DNLD: Error while downloading image to Module [dec], 
Proc. [dec].: [chars]  

Explanation    An error was encountered while downloading an image to a switching module. The first [dec] is the module number, the second [dec] is the process number, and [chars] is the message explanation.

Recommended Action    No action is necessary. This message is provided for informational purposes only.

OSM_MULTILINK Messages

This section contains Optical Services Module distributed multilink (OSM_MULTILINK) messages.

OSM_MULTILINK-3

Error Message    %OSM_MULTILINK-3-PROCESS_FAIL: Process creation failed for [chars] 

Explanation    The system failed to create a process. The probable cause of this condition is that the system has low memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

OSM_MULTILINK-4

Error Message    %OSM_MULTILINK-4-BUNDLEERROR: Bundle([chars]) is not disributed 

Explanation    The bundle specified in the error message is not associated with the OSM.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OSM_MULTILINK-4-BUNDLENULL: Unexpected bundle missing in [chars] 
searching for [chars] 

Explanation    A software error occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OSM_MULTILINK-4-BUNDLEVC: [chars] for vc [dec] and if_index [dec] 

Explanation    A software error occurred while a bundle was being provisioned.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OSM_MULTILINK-4-IDBNULL: Unexpected hwidb missing in [chars] 

Explanation    A software error occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OSM_MULTILINK-4-IPCNOTREADY: Bundle process on the line card is not 
ready to handle message of type [dec] 

Explanation    A bundle is being deleted on the module because the ip cef disable command was entered. The module is not ready to process other messages. The probable cause of this condition is that CEF was disabled and enabled in quick succession.

Recommended Action    Reset the module.

Error Message    %OSM_MULTILINK-4-MLPSBNULL: Unexpected subblock missing for [chars] 

Explanation    A software error occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OSM_MULTILINK-4-NUMLINKS: The bundle had an unexpected number of 
links([dec]) in [chars] 

Explanation    A software error occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %OSM_MULTILINK-4-QUEUE_BUNDLE: Not able to queue the bundle ([chars]), 
Num. of bundles [dec] 

Explanation    A software error occurred while a bundle was being inserted in queue.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

OSM_MULTILINK-5

Error Message    %OSM_MULTILINK-5-BUNDLEEXCEEDED: Bundle([chars]) cannot be associated 
with link([chars]), max [dec] 

Explanation    The number of bundles has exceeded the limit for the group belonging to the link. The bundle specified in the error message will not work in distributed mode. If the module is CT3 (OSM-CT3 module), then ports 1 through 12 belong to one group. If the module is a CHOC-3 module (OSM-CHOC-DS0 module), then ports 1 through 4 belong to one group. If the module is a CHOC-12 module (OSM-CHOC-DS0 module), then port 1 belongs to one group, and port 2 belongs to the second group. Only 168 bundles can be supported per group. The new bundle created will cause an extra load on the RP CPU.

Recommended Action    Remove the multilink interface that is causing this condition.

Error Message    %OSM_MULTILINK-5-CFGERROR: Cannot set up this bundle link-- [chars] to 
bundle [chars] reason:[chars] 

Explanation    The system could not set up the bundle link. A resource limit has been reached. The bundle may be forced to become inactive. If the module is a CT3 module (OSM-CT3 module), then ports 1 through 12 belong to one group. If the module is a CHOC-3 module (OSM-CHOC-DS0 module), then ports 1 through 4 belong to one group. If the module is a CHOC-12 module (OSM-CHOC-DS0 module), then port 1 belongs to one group, and port 2 belongs to the second group. Only 168 bundles can be supported per group, and each bundle can have a maximum of 12 links.

Recommended Action    Ensure that all links belong to the same group and slot. Determine the number of links in the bundle and the number of bundles in the group. After the configuration has been corrected, enter the shutdown and no shutdown commands on the multilink interface to shut down, and restart the interface.

OSPF Messages

This section contains Open Shortest Path First (OSPF) messages.

OSPF-4

Error Message    %OSPF-4-FLOOD_WAR: Process [dec] [chars] LSA ID [IP_address] 
type-[dec] adv-rtr [IP_address] in area [chars] 

Explanation    The system is re-originating or flushing the link-state advertisement (LSA) reported by this error message.

Recommended Action    If this router is flushing the network LSA, then the router received a network LSA whose LSA ID conflicts with the IP address of one of the router's interfaces, and the router has flushed the LSA out of the network. For OSPF to function correctly, the IP addresses of transit networks must be unique. There is a conflict between this router and the router with the OSPF router ID reported as adv-rtr in this message. If this router is reoriginating an LSA, another router is probably flushing this LSA from the network. Locate that router and resolve the conflict. Conflict for type-2 LSA may be due to duplicate LSA ID; for type-5 LSA, there may be a duplicate router-id on this router and on the routers connected to the different area.

PBI_OPEN Messages

This section contains programmable binary file data processing (PBI_OPEN) messages.

PBI_OPEN-4

Error Message    %PBI_OPEN-4-ERROR_ALLOC: %Error: Can't allocate [dec] bytes for pbi 
data 

Explanation    The system is unable to allocate the memory required to access the file.

Recommended Action    Determine system memory usage, and retry the operation.

Error Message    %PBI_OPEN-4-ERROR_OPEN: %Error: Can't open [chars] 

Explanation    The system is unable to open the file specified.

Recommended Action    Ensure that the filename is correct. Enter the dir command to verify the filename.

Error Message    %PBI_OPEN-4-ERROR_READ: %Error: pbi file [chars] read failed 

Explanation    An unknown error occurred while the system was copying the PBI program file to a local buffer.

Recommended Action    Enter the del [chars] command to remove the file. Use the copy command to recopy the file from a known good source to its desired destination [chars]. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %PBI_OPEN-4-ERROR_SIZE: %Error: Bad file size [chars] 

Explanation    The file is too small or too large for a PBI program file.

Recommended Action    Enter the dir command and verify the size of the file. Retry the operation.

PF_ASIC Messages

This section contains protocol filtering (PF_ASIC) messages.

PF_ASIC-1

Error Message    %PF_ASIC-3-ASIC_DUMP: [[dec]:[hex]] [chars] = [hex] 

Explanation    This message displays relevant ASIC counters that might help in diagnosing a problem with the switching bus.

Recommended Action    Copy this message and the SWITCHING_BUS_IDLE message exactly as they appear on the console or in the system log. Contact your Cisco technical support representative with the output. Include this output along with the SWITCHING_BUS_IDLE error message.

PFINIT Messages

This section contains platform initialization (PFINIT) messages.

PFINIT-1

Error Message    %PFINIT-1-CONFIG_SYNC_FAIL: Sync'ing the [chars] configuration to the 
standby Router FAILED 

Explanation    The active router could not synchronize its configuration with the redundant router. This condition might be a transient one that was caused by the configuration file being temporarily used by another process.

Recommended Action    Retry the synchronization operation.

PFINIT-5

Error Message    %PFINIT-5-CONFIG_SYNC_NOT_SUPPORTED: Sync'ing the [chars] 
configuration to the standby Router is not supported.  

Explanation    The configuration has not been successfully synchronized with the standby router. [chars] is the configuration name.

Recommended Action    This is an informational message. No action is required.

PFREDUN Messages

This section contains platform redundancy (PFREDUN) messages.

PFREDUN-1

Error Message    %PFREDUN-1-VTP_CONFIG_DISLOCATE: VTP config file must be in default 
location for standby supervisor to come online 

Explanation    The redundant supervisor engine failed to come online because the VTP configuration file is not in the default location.

Recommended Action    Reset the redundant supervisor engine, and then configure the VTP configuration file so that it is in the default location.

PFREDUN-3

Error Message    %PFREDUN-3-ACTIVE_FORCED_TO_RELOAD: Active not able to operate 
properly. Standby is ready to take over and forced active to reload. 

Explanation    The active supervisor engine is not operating properly. It is failing to respond. The standby supervisor engine is ready to take over and forces the active supervisor engine to reload.

Recommended Action    If the active supervisor engine does not reload successfully, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %PFREDUN-3-SUP: [chars] 

Explanation    The supervisor engine failed to boot because it detected that the system might contain an invalid combination of supervisor engines.

Recommended Action    Examine all modules in the system, and look for an invalid combination of supervisor engines.

PFREDUN-4

Error Message    %PFREDUN-4-AUTOBOOT: [chars] 

Explanation    The RP experienced a hardware failure or another type of failure. When the redundant system initializes, the redundant supervisor engine will wait for the RP to initialize. Because the RP cannot initialize due to the failure, the redundant supervisor engine might never initialize. The default wait time for the RP to initialize (three minutes) has now expired, and the autoboot feature for the supervisor engine has been disabled.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %PFREDUN-4-BOOTSTRING_INVALID: The bootfile [chars] is not present in 
standby

Explanation    The bootfile that is configured is not present on the redundant supervisor engine. If the redundant supervisor engine resets, it will not come up because it will not find the image specified in the bootstring.

Recommended Action    No action is required.

Error Message    %PFREDUN-4-PFC_MISMATCH: My PFC [chars] and Other's PCF [chars] 
mismatch

Explanation    The active supervisor engine and the redundant supervisor engine have different versions of the PFC daughter card.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %PFREDUN-4-PHYSMEM_MISMATCH: Asymmetrical redundant configuration: 
Active [chars] has ([int]/[int]K) memory, Standby has ([int]/[int]K). 

Explanation    To support the high availability feature, we recommend that your redundant supervisor engines have symmetrical memory configurations.

Recommended Action    Upgrade the memory on the supervisor engine with less memory to match the amount of memory on the other supervisor engine.

Error Message    %PFREDUN-4-SUP_FORCE_TO_ROMMON: Supervisor forced to rommon with 
reason: [chars] 

Explanation    An application forced the supervisor to stay in ROMMON mode. The message displays the reason.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %PFREDUN-4-SUP_OS: The peer supervisor is running a different 
operating system. 

Explanation    Either the two supervisor engines are running different operating systems, or the active supervisor engine is in user-configured mode (for example, DFC-only mode). Incompatible software prevents the active supervisor engine from bringing the standby supervisor engine on line. The active supervisor engine keeps the standby supervisor engine in ROMMON mode.

Recommended Action    If the two supervisor engines are running different operating systems, insert a supervisor that runs the same operating system as that of the peer supervisor. If the active supervisor engine is in user-configured mode, remove the user-configured mode on the active supervisor engine.

Error Message    %PFREDUN-4-VERSION_MISMATCH: Defaulting to RPR mode ([chars]) 

Explanation    There is a mismatch of image versions running on the active supervisor engine and on the redundant supervisor engine.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

PFREDUN-7

Error Message    %PFREDUN-7-KPA_WARN: RF KPA messages have not been heard for [dec] 
seconds 

Explanation    The RF KPA messages have not been sent from the peer for the specified numbers of seconds. This message is printed after every third KPA timer expiry.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

PIMSN Messages

This section contains PIM (Protocol Independent Multicast) Snooping (PIMSN) messages.

PIMSN-6

Error Message    %PIMSN-6-IGMPSN_GLOBAL: PIM Snooping global runtime mode [chars] due 
to IGMP Snooping [chars] 

Explanation    PIM snooping requires that IGMP snooping be enabled. When IGMP snooping is disabled, PIM snooping also becomes disabled. PIM snooping is reenabled when IGMP snooping is reenabled.

Recommended Action    No action is required. The system is working properly. We recommend that you leave IGMP snooping enabled.

Error Message    %PIMSN-6-IGMPSN_VLAN: PIM Snooping runtime mode on vlan [dec] [chars] 
due to IGMP Snooping [chars] 

Explanation    PIM snooping requires that IGMP snooping be enabled. When IGMP snooping is disabled, PIM snooping also becomes disabled. PIM snooping is reenabled when IGMP snooping is reenabled.

Recommended Action    No action is required. The system is working properly. We recommend that you leave IGMP snooping enabled.

PISA Messages

This section contains Programmable Intelligent Services Accelerator (PISA) messages.

PISA-3

Error Message    %PISA-3-GENERIC_ME_ERROR: microengine [dec] thread [dec] param1 [hex] 
param2 [hex] param3 [hex] param4 [hex] param5 [hex] param6 [hex] param7 [hex] 

Explanation    This message is for testing the debug mechanism of the PISA generic microengine error definition.

Recommended Action    No action is required.

Error Message    %PISA-3-MQC_ATTACH_POLICY: Failed to attach policy-map [chars] to 
interface [chars] on [chars] direction. [chars] 

Explanation    PISA MQC policy-map attachment failed because of one of the following policies: convert ixp-policy, add ixp-policy to vlan, write ixp-policy, or attach acls in ixp-policy.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %%PISA-3-MQC_MODIFY_POLICY: Failed to modify policy-map [chars] from 
interface [chars] on [chars] direction. [chars] 

Explanation    Failed to modify the PISA MQC policy map because the ixp-policy was not found, or the parameters are invalid, or the user failed to remove or attach the policy.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %%PISA-3-MQC_REMOVE_POLICY: Failed to remove policy-map [chars] from 
interface [chars] on [chars] direction. [chars] 

Explanation    Removal of the PISA MQC policy map failed because the ixp-policy was not found, or the parameters are invalid, or data structures are corrupted.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %PISA-3-NBAR_PD_ERROR: Protocol Discovery error on [chars] for vlan 
[dec] 

Explanation    An error exists in the Network Based Application Recognition (NBAR) protocol discovery configuration.

Recommended Action    Recheck the NBAR configurations. Contact TAC if needed.

Error Message    %PISA-3-SYSLOG_FPM: microengine [dec] thread [dec] param1 [hex] param2 
[hex] param3 [hex] param4 [hex] param5 [hex] param6 [hex] param7 [hex] 

Explanation    This message is for testing the debug mechanism of the PISA FPM syslog definition.

Recommended Action    No action is required.

Error Message    %PISA-3-SYSLOG_TEST: microengine [dec], thread [dec] 

Explanation    This message is for testing the debug mechanism of the PISA syslog test.

Recommended Action    No action is required.

PISA-4

Error Message    %PISA-4-PISA_CHANNEL_ADD: Uplink port g[dec]/[dec] will be used for 
internal PISA channel. 

Explanation    The uplink port is shared with the internal PISA channel port.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA-4-PISA_CHANNEL_CFG: Configuration commands must not be applied 
on PISA-channel port(s). 

Explanation    Configuration commands that are executed on PISA channel ports may disrupt the channel.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA-4-PISA_CHANNEL_REM: Uplink port g[dec]/[dec] will revert to 
default configuration. 

Explanation    Any nondefault uplink port configuration must be reapplied.

Recommended Action    Reapply any nondefault uplink port configuration.

Error Message    %PISA-4-PISA_INTERNAL_VLAN_ALLOC: Internal vlan not available. Packets 
on [chars] will be software switched by RP 

Explanation    The internal VLAN allocation for split VLAN failed.

Recommended Action    Make some VLANs available for use by the internal VLANs, and then reapply the configuration.

Error Message    %PISA-4-PISA_INTF_EXCEPTION: INTF exception occurred in [chars] 
direction for vlan [dec]. Packets will be punted to RP 

Explanation    Either a TCAM exception occurred or an exception due to incompatible interface configurations occurred.

Recommended Action    Remove any incompatible interface configurations and reconfigure the ACL features.

PISA_FM Messages

This section contains Programmable Intelligent Services Accelerator (PISA) Feature Manager (FM) messages.

PISA_FM-5

Error Message    %PISA_FM-5-ACL_DISABLED: [chars] [chars] is removed from [chars] in 
[chars] direction. 

Explanation    The specified ACL or reverse ACL has been disabled on the specified interface in the input or output direction. Packets selected by the ACL will no longer be routed to the Programmable Intelligent Services Accelerator (PISA) for modification.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA_FM-5-ACL_ENABLED: [chars] [chars] is applied on [chars] in 
[chars] direction. 

Explanation    The specified ACL or reverse ACL has been enabled on the specified interface in the input or output direction. Packets selected by the ACL will be routed to the Programmable Intelligent Services Accelerator (PISA) for modification.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA_FM-5-FEATURE_DISABLED: PISA Feature is disabled on [chars] in 
[chars] direction. 

Explanation    The Programmable Intelligent Services Accelerator (PISA) feature has been disabled on the specified interface in the input or output direction.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA_FM-5-FEATURE_ENABLED: PISA Feature is enabled on [chars] in 
[chars] direction. 

Explanation    The Programmable Intelligent Services Accelerator (PISA) feature has been enabled on the specified interface in the input or output direction.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA_FM-5-INSPECT_ACL_DISABLED: [chars] [chars] is removed from 
[chars] in [chars] direction. 

Explanation    The specified inspect ACL or reverse inspect ACL has been disabled on the specified interface in the input or output direction. Packets selected by the ACL will no longer be routed to the Programmable Intelligent Services Accelerator (PISA) for inspection.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA_FM-5-INSPECT_ACL_ENABLED: [chars] [chars] is applied on [chars] 
in [chars] direction. 

Explanation    The specified inspect ACL or reverse inspect ACL has been enabled on the specified interface in the input or output direction. Packets selected by the ACL will be routed to the Programmable Intelligent Services Accelerator (PISA) for inspection.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA_FM-5-INSPECT_ALL_DISABLED: [chars] [chars] is removed from 
[chars] in [chars] direction. 

Explanation    The inspect all feature has been disabled on the specified interface in the input or output direction. Packets in the specified direction will no longer be routed to the Programmable Intelligent Services Accelerator (PISA) for inspection.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %PISA_FM-5-INSPECT_ALL_ENABLED: [chars] [chars] is applied on [chars] 
in [chars] direction. 

Explanation    The inspect all feature has been enabled on the specified interface in the input or output direction. All packets in the specified direction will be routed to the Programmable Intelligent Services Accelerator (PISA) for inspection.

Recommended Action    No action is required. This message is for informational purposes only.

PISAL2M Messages

This section contains Programmable Intelligent Services Accelerator (PISA) Layer 2 Module (L2M) messages.

PISAL2M-2

Error Message    %PISAL2M-2-ERROR: [chars] [chars]:[dec] 

Explanation    A software error occurred. The message provides information that might be useful in troubleshooting.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

PISAL2M-3

Error Message    %PISAL2M-3-ERROR_STAT: [chars] stat:[dec] in [chars]:[dec] 

Explanation    A software error occurred. The message provides information that might be useful in troubleshooting.

Recommended Action    Copy the error message exactly as it appears, and report it to your technical support representative.

PISAL2M-4

Error Message    %PISAL2M-4-PISA_L2_SVI_INCONSISTENCY: Config Inconsistency : Feature 
acc at [chars] with [chars] not ADMINDOWN 

Explanation    Feature acceleration should be configured on an interface only while its switch virtual interface (SVI) is in the administratively down state.

Recommended Action    Remove the feature acceleration or shut down the SVI and reconfigure.

Error Message    %PISAL2M-4-WARNING: [chars] [chars]:[dec] 

Explanation    A software error occurred. The message provides information that might be useful in troubleshooting.

Recommended Action    Copy the warning message exactly as it appears, and report it to your technical support representative.

PISAL2M-6

Error Message    %PISAL2M-6-FPM_ACCEL_DISABLED: feature disabled on [chars] direction 
of: [chars] 

Explanation    Flexible Packet Matching (FPM) acceleration is disabled. This traffic will not be sent to PISA.

Recommended Action    No action is required.

Error Message    %PISAL2M-6-FPM_ACCEL_ENABLED: feature accelerated on [chars] direction 
of: [chars] 

Explanation    Flexible Packet Matching (FPM) acceleration is enabled. This traffic is sent to PISA.

Recommended Action    No action is required.

Error Message    %PISAL2M-6-NBAR_ACCEL_DISABLED: feature disabled on [chars] direction 
of: [chars] 

Explanation    Network Based Application Recognition (NBAR) acceleration is disabled. This traffic is not sent to PISA.

Recommended Action    No action is required.

Error Message    %PISAL2M-6-NBAR_ACCEL_ENABLED: feature accelerated on [chars] 
direction of: [chars] 

Explanation    Network Based Application Recognition (NBAR) acceleration is enabled. This traffic is sent to PISA.

Recommended Action    No action is required.

Error Message    %PISAL2M-6-NBAR_PD_ACCEL_DISABLED: Protocol Discovery disabled on 
[chars] direction of: [chars] 

Explanation    NBAR protocol discovery acceleration is disabled. This traffic is not sent to PISA.

Recommended Action    No action is required.

Error Message    %PISAL2M-6-NBAR_PD_ACCEL_ENABLED: Protocol Discovery accelerated on 
[chars] direction of: [chars] 

Explanation    NBAR protocol discovery acceleration is enabled. This traffic will be sent to PISA.

Recommended Action    No action is required.

Error Message    %PISAL2M-6-NBAR_TAGGING_DISABLED: NBAR protocol Tagging disabled on 
[chars] direction of: [chars] 

Explanation    NBAR protocol tagging is disabled. This traffic will not be sent to PISA.

Recommended Action    No action is required.

Error Message    %PISAL2M-6-NBAR_TAGGING_ENABLED: NBAR protocol Tagging enabled on 
[chars] direction of: [chars] 

Explanation    NBAR protocol tagging is enabled. This traffic will be sent to PISA.

Recommended Action    No action is required.

PM Messages

This section contains port manager (PM) messages.

PM-1

Error Message    %PM-1-INCONSISTENT_PORT_STATE: Inconsistent HW/SW port state for 
[chars]. Please shut/no shut the interface 

Explanation    The hardware and software port state has become inconsistent. [chars] is the interface.

Recommended Action    No action is necessary. This message is for informational purposes only.

PM-4

Error Message    %PM-4-MPLS_MTU_EC_CFG: MPLS MTU size [dec] is not supported by one or 
more ports in channel [chars]. 

Explanation    The MPLS MTU size that was configured on the Ethernet channel is larger than the maximum MTU size that can be supported by one or more ports in this channel. Large packets might be dropped.

Recommended Action    Reduce the MPLS MTU size, or remove these ports from the channel before increasing the MPLS MTU size.

Error Message    %PM-4-MPLS_MTU_PORT_CFG: MPLS MTU size [dec] is not supported by port 
[chars]. 

Explanation    The MPLS MTU size that was configured on the port is larger than the maximum MTU size that can be supported by this port. Large packets might be dropped.

Recommended Action    Reduce the MPLS MTU size.

Error Message    %PM-4-PORT_BOUNCED: Port [chars] was bounced by [chars].

Explanation    During a switchover, the PM needed to perform a reactivation of a port that was in the link-down state. A port is only reactivated when the port data structures lack consistency between the active and redundant supervisor engines. Active ports in the link-down state were returned to the link-up state by the reactivation event.

Recommended Action    No action is required.

PM_SCP Messages

This section contains port manager Switch-Module Configuration Protocol (PM_SCP) messages.

PM_SCP-1

Error Message    %PM_SCP-1-LCP_FW_ERR_POWERDOWN: Module [dec] will be powered down due 
to firmware error: [chars] 

Explanation    A nonrecoverable error was detected by the switching module firmware and the switching module will be powered down to keep the system functioning. [dec] is the module number and [chars] explains that the system will be powered down.

Recommended Action    No action is required.

PM_SCP-2

Error Message    %PM_SCP-2-TRANSCEIVER_INCOMPATIBLE: Transceiver inserted in [chars] 
port [dec]/[dec] is not compatible with its interface (transceiver speed is 
[chars], interface speed is [chars]) 

Explanation    An incompatible transceiver was inserted in the specified module. This transceiver should not be used with this module.

Recommended Action    Replace the specified transceiver with another transceiver that is compatible with this module.

PM_SCP-4

Error Message    %PM_SCP-4-FPOE_INFO: An unsupported distributed fabric card has been 
detected 

Explanation    Fabric-capable modules are not supported in this system.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %PM_SCP-4-UNSUPPORTED: Interface [chars] does not support receive-only 
transceivers 

Explanation    A receive-only transceiver has been inserted into a slot that does not support it.

Recommended Action    Use the receive-only transceiver with a supported module.

POSLC Messages

This section contains Packet over SONET module (POSLC) messages.

POSLC-3

Error Message    %POSLC-3-PROCESS_CREATEFAIL: [chars] 

Explanation    The PoS module could not create a process required for its operation. This condition might occur because a resource is unavailable.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %POSLC-3-PROCESS_TIMEREVENT: [chars] 

Explanation    An unexpected process timer event occurred on the OSM.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %POSLC-3-UNEXPECTED_PROCESSEVENT: [chars] 

Explanation    An unexpected process event occurred on the OSM.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

QM Messages

This section contains Quality of Service Management (QM) messages.

QM-2

Error Message    %QM-2-PLC_ATTACH_REJECT_2_PLCRS: Command rejected: (policy [chars] 
interface [chars] dir [chars]) police and police aggregate commands present in 
same traffic class 

Explanation    This message indicates one of two conditions: either a policy map that contains a traffic class with both police and police aggregate commands is attached to an unsupported interface or a policy attached to an interface is being modified in an unsupported manner.

Recommended Action    Remove the unsupported command combination from the same traffic class. In the case of a modification to a policy that is already attached to unsupported interfaces, no action is required because the command is automatically rejected.

Error Message    %QM-2-PLC_ATTACH_REJECT_SET: Command rejected: (policy [chars] 
interface [chars] dir [chars]) police/trust and set commands present in same 
traffic class 

Explanation    This message indicates one of two conditions: either a policy map that contains a traffic class with both set and police/trust commands is attached to an unsupported interface or a policy attached to an interface is being modified in an unsupported manner.

Recommended Action    Remove the unsupported command combination from the same traffic class. In the case of a modification to a policy that is already attached to unsupported interfaces, no action is required because the command is automatically rejected.

QM-4

Error Message    %QM-4-AGG_POL_EXCEEDED: QoS Hardware Resources Exceeded : Out of 
Aggregate policers 

Explanation    Only a limited number of aggregate policers can be supported. On EARL7-based switches, this limit is 1023.

Recommended Action    Attempt to aggregate policers if possible.

Error Message    %QM-4-MFLOW_POL_EXCEEDED: QoS Hardware Resources Exceeded : Out of 
Micro flow policers 

Explanation    Only a limited number of microflow policers can be supported. On EARL7-based switches, this limit is 63.

Recommended Action    No action is required.

QM-6

Error Message    %QM-6-EOM_FORCE_TRUSTED: EoMPLS on [chars] caused install of 'trust 
cos' state 

Explanation    If EoMPLS is configured on the interface or any of its subinterfaces, the "no trust" state is automatically replaced by the "trust CoS" state.

Recommended Action    Remove all EoMPLS configurations from the interface to restore the "no trust" state.

Error Message    %QM-6-EOM_RESTORE_UNTRUSTED: The 'no trust' state is restored on 
EoMPLS removal from [chars] 

Explanation    If EoMPLS is unconfigured on the interface and all its subinterfaces, the "no trust" state is restored.

Recommended Action    No action is required.

Error Message    %QM-6-EOM_TRUST_NOT_INSTALLED: 'no trust' command is not installed on 
[chars] in presence of EoMPLS 

Explanation    If EoMPLS is configured on the interface or any of its subinterfaces, the no trust command is not installed.

Recommended Action    Remove all EoMPLS configurations from the interface.

R4K_MP Messages

This section contains central processing unit (R4K_MP) messages.

R4K_MP-3

Error Message    %R4K_MP-3-CRASHED: CPU [dec] has now crashed a total of [dec] times. 

Explanation    The specified CPU failed the specified number of times and has been restarted.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

R4K_MP-5

Error Message    %R4K_MP-5-DELEGATE_GETBUF: Delegated call to [hex] failed, out of 
buffers 

Explanation    An RPC to the specified function failed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

REGISTRY Messages

This section contains registry-related (REGISTRY) messages.

REGISTRY-2

Error Message    %REGISTRY-2-REG_FLAG_DEADLOCK: Registry call to [chars] timed out due 
to deadlock 

Explanation    When a remote registry is not serviced within 25 seconds, the remote process (and presumably the entire system) is deadlocked. This message is printed when the deadlock is broken by a timeout.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %REGISTRY-2-REG_PARSE_ERROR: [chars]: Could not parse notification 
[chars] : error/no. of items = [dec] 

Explanation    The registry library is unable to parse a notification that was received from a name server. This condition might exist for several reasons:

–There is a bug in the sscanf function.

–The notification block is corrupted.

–The pathname published to the name server is invalid.

This issue is serious and affects IPC.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

RF Messages

This sections contains redundancy feature (RF) messages.

RF-3

Error Message    %RF-3-FAILED_SET_RED_MODE: ACTIVE failed to set redundancy mode. 
STANDBY has selected mode but unable to get confirmation from ACTIVE. 

Explanation    Under normal conditions, the standby route processor (RP) has selected the redundancy mode and sends its decision to active RP. The active RP uses it to determine the system mode and sends the final decision on the mode back to standby RP. This system message indicates that the exchange has failed, and the standby RP does not have the right redundancy mode to proceed.

Recommended Action    Allow the standby RP to reset once. If the problem persists, verify that all modules are working properly.

Error Message    %RF-3-NON_HA_SWITCHOVER: The SP switchover was NOT stateful. To 
support SSO on the RP, the SP must be configured with HA enabled. 

Explanation    The switch processor switchover that occurred was not stateful. Stateful switchover mode on the route processor requires the switch processor to run with high availability (HA) enabled to ensure that appropriate state is synchronized between the switch processors and that there is sufficient state information on the new active switch processor to support the switchover of the route processor while in stateful switchover mode. The recovery is to reset and reboot the route processor, because there is insufficient state information to support a route processor switchover in stateful switchover mode.

Recommended Action    Configure the SP to enable HA. If HA is enabled, it is possible that resource exhaustion (such as memory) might have caused this non-HA switchover. If the problem persists, contact Cisco technical support representative for further analysis.

Error Message    %RF-3-PEER_RP_RELOAD: The peer Route Processor (RP) is being reset 
because [chars] 

Explanation    This message provides the reason that the peer RP was reset. The peer RP resets in an attempt to recover from an indeterminate state.

Recommended Action    If the condition persists after the reset, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %RF-3-WAKEUP_STANDBY_NOT_SEEN: Active-Standby RP Handshake Error.  The 
Standby RP did not receive a WAKEUP_STANDBY message from the Active RP during the 
early initialization phase on the Standby RP.

Explanation    As part of the early initialization phase, the standby route processor (RP) asks the active RP to awaken it when the active RP is ready to support the standby RP. The active RP has failed to awaken the standby RP. The active RP may have failed during the standby RP's early initialization phase or some other error has prevented the active RP from completing this handshake.

Recommended Action    The standby RP will be restarted. If the problem persists, restart the system.

RF-6

Error Message    %RF-6-STANDBY_READY: The Standby RP has reached HOT-STANDBY state and 
is now ready for stateful switchover. 

Explanation    The standby route processor (RP) has reached the hot-standby state and is now ready to take over operation in the event that the active RP should fail.

Recommended Action    No action is required.

RPC Messages

This section contains Remote Procedure Call (RPC) messages.

RPC-2

Error Message    %RPC-2-FAILED: Failed to send RPC request [chars] (fatal) 

Explanation    A fatal communication error occurred during an RPC request.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %RPC-2-FAILED_RETRY: Failed to send RPC request [chars] (will try 
again) 

Explanation    A communication error occurred during an RPC request. The system will attempt the RPC request again.

Recommended Action    If the attempt to send the RPC request fails again, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %RPC-2-FAILED_USERHANDLE: Failed to send RPC request [chars] 

Explanation    A communication error occurred during an RPC request.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

RPF Messages

This section contains Reverse Path Forwarding (RPF) messages.

RPF-3

Error Message    %RPF-3-RTAVLDELETE: Error deleting an rpf entry from the multicast rpf 
tree 

Explanation    An internal software error occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter at https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center using the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

Error Message    %RPF-3-RTAVLINSERT: Error inserting a new rpf entry into the multicast 
rpf tree

Explanation    An internal software error occurred.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter at https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

RP_MLP Messages

This section contains Route Processor Multilink Point-to-Point Protocol (RP_MLP) messages.

RP_MLP-4

Error Message    %RP_MLP-4-DLFIONELINKSUPPORT: Only ONE link should be configured for 
dLFI bundle!! 

Explanation    The system attempted to configure more than one link for the Distributed Link Fragmentation and Interleaving (dLFI) bundle interface. The dLFIoFR and the dLFIoATM do not support configuring more than one link.

Recommended Action    No action is required.

RUNCFGSYNC Messages

This section contains Auto-Running Configuration Synchronization (RUNCFGSYNC) messages.

RUNCFGSYNC-6

Error Message    %RUNCFGSYNC-6-HASRMSTATE: [chars] 

Explanation    The high availability (HA) single router mode has changed state. Additional details are provided in the error message text.

Recommended Action    No action is required.

SBFIFO Messages

This section contains MAC FIFO controller (SBFIFO) messages.

SBFIFO-1

Error Message    %SBFIFO-1-BAD_IDB: Invalid Interface Descriptor Block 

Explanation    The driver failed to get the interface IDB.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-BAD_PARTICLE: Problem getting particle size 

Explanation    The driver was unable to obtain the particle size for this interface.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-BAD_POOL: Could not init buffer pools 

Explanation    The driver failed to obtain a pool of buffers from the Cisco IOS software.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-BAD_SB_NOMEM: [chars] - Cannot create IDB subblock due to 
insufficient memory 

Explanation    There was insufficient system memory to create the IDB subblock.

Recommended Action    The router requires more memory. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-BAD_STRUCT: Could not initialize structure 

Explanation    The driver failed to initialize a structure.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-BAD_SUBBLOCK: [chars] - Could not install or use IDB subblock 

Explanation    An internal Cisco IOS error prevented the IDB subblock from being installed or used.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-IDBTYPE_UNK: Unknown IDBTYPE while starting driver 

Explanation    The IDBTYPE in the instance structure of the interface is undefined for this driver.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-INITFAIL_NOMEM: [chars], initialization failed, no buffer 
memory 

Explanation    The Ethernet port initialization failed due to insufficient memory. The router requires more packet memory.

Recommended Action    Consider a system upgrade. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-MODE_INVALID: Unknown or invalid chip mode (MII/TBI) 

Explanation    The driver subblock contains an invalid or undefined chip operating mode (MII or TBI mode).

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-1-RESET: MAC-FIFO Still in Reset 

Explanation    The system attempted to access the MAC-FIFO while it was still being reset.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SBFIFO-3

Error Message    %SBFIFO-3-ERRINT: [chars], error interrupt, mac_status = [hex] 

Explanation    The MAC-FIFO controller signalled an error condition.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SBFIFO-3-TOOBIG: [chars], packet too big ([dec]), from [enet] 

Explanation    The interface detects a packet larger than the value that is defined by MTU.

Recommended Action    Determine the MTU setting of the other station. No action is required.

SCP Messages

This section contains Switch Module Configuration Protocol (SCP) messages.

SCP-3

Error Message    %SCP-3-SCP_HA_FAIL: SCP HA Seq Set - Module: [dec] failed [dec] times 

Explanation    The system did not receive the SCP HA sequence set acknowledgment.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SCP-5

Error Message    %SCP-5-ASYNC_WATERMARK: [dec] messages pending in [chars] 

Explanation    The specified number of SCP messages are waiting in the specified local queue. This condition might indicate that the SP is generating many messages, that the SP is to busy too send them, or that the module cannot process them at a faster pace. In most cases, this condition occurs when there is heavy control plane activity, such as the formation of Layer 2 trunks, the addition of new VLANs, or the toggling of links.

Recommended Action    Determine if the SP is busy or if there is interface link toggling. If this condition persists for more than five minutes, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SCP-5-ENABLE: Module enabled [chars] 

Explanation    The supervisor engine sent a message to the router to indicate that a module has been enabled.

Recommended Action    No action is required.

SFF8472 Messages

This section contains Optical Transceiver Diagnostic Monitoring (SFF8472) messages.

SFF8472-2

Error Message    %SFF8472-2-NOMEM: Not enough memory available for [chars]

Explanation    The SFF8472 subsystem could not obtain the memory it needed.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SFF8472-3

Error Message    %SFF8472-3-INTERNAL_ERROR: [chars]

Explanation    The SFF8472 subsystem encountered an internal software error. The error message contains text that can be used to help identify the nature of the problem.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SFF8472-3-READ_ERROR: [chars] 

Explanation    An error occurred when the system was reading the digital optical monitoring information from the transceiver at the specified interface.

Recommended Action    Remove and reinsert the transceiver. If the transceiver still does not work, replace it.

Error Message    %SFF8472-3-THRESHOLD_VIOLATION: [chars]: [chars]; Operating value: 
[chars], Threshold value: [chars].

Explanation    There has been a threshold violation. The violation is specified in the message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SFF8472-3-UNEXPECTEDEVENT: Process received unknown event (maj [hex], 
min [hex]).

Explanation    A process can register to be notified when various events occur. A process received an event that it did not know how to handle.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SIBYTE_ION

This section contains Sibyte Ion messages.

SIBYTE_ION-3

Error Message    %SIBYTE_ION-3-SB_THREAD_CTL_ERR: Call to ThreadCTL() failed: function 
= [chars], line number = [dec], return_code = [dec], errno = [dec]  

Explanation    A QNX call to ThreadCTL() failed. [chars] is the function, the first [dec] is the line number, the second [dec] is the return code, and the third [dec] is the error number.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

SIP400 Messages

This section contains SPA Interface Processor 400 (SIP400) messages.

SIP400-2

Error Message    %SIP400-2-IOBUS_ERROR: IO bus error occurred: [chars] last addr [hex] 
data [hex] tran [hex] 

Explanation    A device on the I/O bus had a communication problem.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP400-2-PCI_BUS_ERROR: A PCI Bus Error occurred while trying to 
access a device (status reg = [hex], addstatus reg = [hex]) 

Recommended Action    A PCI bus error occurred while trying to access a device.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP400-2-PCI_ERROR_INT: A PCI Error interrupt occurred while trying 
to access a device (status reg = [hex], addstatus reg = [hex]) 

Explanation    A PCI error interrupt occurred while trying to access a device.

Recommended Action    If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SIP600 Messages

This section contains SPA Interface Processor 600 (SIP600) messages.

SIP600-2

Error Message    %SIP600-2-DEVMGR_ASIC_INIT_FAILED: SIP-600 ASIC Initialization failed 
at stage-asic_init[dec] 

Explanation    The SIP 600 received an error when attempting to initialize the ASICs that make up the forwarding hardware. A hardware problem has prevented the SIP 600 from fully initializing on the line card. Packets will not be forwarded.

Recommended Action    Reload the line card. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-2-DEVMGR_PROC_CREATE_FAILED: SIP-600 Initialization failed to 
create a required IOS process[dec] 

Explanation    The SIP 600 received an error during initialization when attempting to create the ASIC "stage2 init" process. A memory problem or another software resource problem has prevented the SIP 600 from fully initializing on the line card. Packets will not be forwarded.

Recommended Action    Reload the line card. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-2-INITFAIL: SIP-600 Initialization Failed - [chars]: [chars] 
[dec] [dec] 

Explanation    The SIP 600 could not initialize the memory that is needed for the feature that is specified in the message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-2-NULL_OBJECT: Missing device object ([chars]) for pending 
interrupt 

Explanation    A hardware device asserted an interrupt to report an event, but there is no device object for this device.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-2-NULL_SPA_BAY_OBJECT: SPA Bay [dec] is missing 

Explanation    A SPA bay object is missing.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-2-PE_BUS_UNRECOVERABLE_INT: Packet Engine Unrecoverable Bus 
Interrupt: [chars] = [hex] 

Explanation    A packet engine unrecoverable bus interrupt has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-2-QUPDATE: SIP-600 Update Queue Hardware Failed - [chars]: 
[chars] [dec] Cause: [hex] 

Explanation    The SIP 600 received an error on the specified hardware queue when attempting the specified action. A hardware problem has prevented system queues from being updated on the line card. Packets might no be forwarded.

Recommended Action    Reload the line card. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-2-UNRECOVERABLE_FAILURE: SIP-600 Unrecoverable Failure 

Explanation    An unexpected fatal condition has occurred on the SIP 600. This message indicates a hardware failure or malfunction. The system will reload to attempt to fix the problem. See the previous error on the console or in the system log for specific details about the condition.

Recommended Action    If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SIP600-3

Error Message    %SIP600-3-IO_BUS_ERR_INT: IO Bus Error Interrupt: [hex] - Deadman 
Timer = [hex] Trans Status = [hex] Last Address = [hex] Last Data = [hex] 

Explanation    An I/O bus error interrupt has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-NMI: NMI Reset Status = [hex] 

Explanation    A nonmaskable interrupt occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-NOMEM: [chars] 

Explanation    The OSM could not obtain statistics because of insufficient memory.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-NO_STATID: PXF([dec]): no stat_id is available for 
statistics collection 

Explanation    The OSM has used up all statistics-collection resources. No resources are available for further statistics collection.

Recommended Action    Reduce the number of features configured on the specified PXF. If conditions warrant, copy the error message exactly as it appears on the console or in the system log, and contact your Cisco technical support representative.

Error Message    %SIP600-3-NO_STAT_PROCESS: Failed to create stat process 

Explanation    The SIP 600 failed to create a statistics process. All statistics counters will be zero.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-PE_BUS_ERR_INT: Packet Engine Bus Error Interrupt: [chars] 

Explanation    A packet engine bus error interrupt has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-PE_SPA_BUS_ERR_INT: SPA Bus Error Interrupt: SPA Bus Error 
Status ([hex]) = [hex], SPA Bus Trans Status ([hex]) = [hex], SPA Bus Last Data 
([hex]) = [hex] 

Explanation    A SPA bus error interrupt has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-PE_UNEXPECTED_INT: Unexpected Packet Engine Interrupt: 
[chars] 

Explanation    An unexpected packet engine interrupt has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-SIP10G_GEN_DEV_ERR: [chars] unexpected error: [chars] 

Explanation    The software driver for the specified SIP-600 device has detected an unexpected condition. The condition is specified in the message.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-STATID_INCONSISTENCY: PXF([dec]):Inconsistent stats 
id([hex]) [int] packets dropped. 

Explanation    A WAN line card has received inconsistent statistics from PXF. PXF reported that one or more packets have been dropped, but no corresponding packet count has been reported.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-UNEXPECTED_GLOBAL_INT: Unexpected Global Interrupt: [chars] 

Explanation    An unexpected global interrupt has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-3-UNSUPPORTED_LABEL_RANGE: The maximum label range configured 
for this system exceeds
the [int] limit supported by the OSM module.

Explanation    The MPLS label range that was configured for this system is not supported. The maximum label range limit is specified in the message.

Recommended Action    Change the maximum MPLS label range by entering the mpls label range command.

SIP600-4

Error Message    %SIP600-4-INVALID_STATID: PXF:Invalid-Statid ([dec]) for vc [int] 
under interface [int] 

Explanation    The OSM encountered an internal error while setting up the statistics report subsystem.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600-4-SIP10G_PXF_IRAM_PARITY_ERROR: Correcting a PXF instruction 
error.

Explanation    This is a Parallel Express Forwarding (PXF) error message that indicates a detection and correction of a typically rare event. If the error is persistent, it may indicate faulty hardware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

SIP600-6

Error Message    %SIP600-6-NULLQID: PXF([dec]):Null-QID ([chars]) [int] packets 
dropped. 

Explanation    A Catalyst 6500 series switch or a Cisco 7600 series router line card encountered an invalid queue. A packet has been dropped. The packet will be counted in the null queue statistics, and packet traffic should continue normally.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SIP600_PARSING_ENGINE Messages

This section contains SPA Interface Processor 600 parsing engine (SIP600_PARSING_ENGINE) messages.

SIP600_PARSING_ENGINE-3

Error Message    %SIP600_PARSING_ENGINE-3-DROP_FIFO_OVERFLOW: Parsing Engine Drop Fifo 
Overflow 

Explanation    The SIP-600 parsing engine has detected that the drop FIFO queue has exceeded the maximum limit. New updates will be discarded. The parsing engine continues to process data from the interfaces if possible.

Recommended Action    If traffic resumes, no action is required. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_PARSING_ENGINE-3-INTERRUPT_ERROR: [chars] 

Explanation    The SIP-600 parsing engine has detected the specified interrupt event. The message text on the console or in the system log provides more information about this error. The parsing engine continues to process data from the interfaces if possible.

Recommended Action    If traffic resumes, no action is required. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_PARSING_ENGINE-3-MASTER_ABORT: Parsing Engine CPU Master Abort 
Error 

Explanation    The SIP-600 parsing engine has detected a CPU master abort interrupt. A read-only to write-only register or a write-only to read-only register could cause this interrupt. The parsing engine continues to process data from the interfaces, if possible.

Recommended Action    If traffic resumes, no action is required. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_PARSING_ENGINE-3-PARITY_ERROR: Parsing Engine CPU Parity Error 

Explanation    The SIP-600 parsing engine has detected a CPU parity error. Suspect a hardware fault on the second occurrence of this message. Otherwise, the parsing engine continues to process data from the interface, if possible.

Recommended Action    If traffic resumes, no action is required. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_PARSING_ENGINE-3-RP_INT_WATCHDOG_TIMEOUT: Parsing Engine RP 
Interface Watchdog Timeout 

Explanation    The SIP-600 parsing engine has detected an RP interface watchdog timeout. The RP interface process has not relinquished the processor for the watchdog timeout period. The parsing engine continues to process data from the interfaces if possible.

Recommended Action    If traffic resumes, no action is required. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SIP600_QOS Messages

This section contains SPA Interface Processor 600 quality of service (SIP600_QOS) messages.

SIP600_QOS-2

Error Message    %SIP600_QOS-2-INITFAIL: SIP-600 Initialization Failed [chars]: [chars] 
[dec] [dec] 

Explanation    The SIP 600 could not initialize the memory that is needed for the QoS feature. A hardware problem has occurred on the line card that prevents QoS from functioning.

Recommended Action    If QoS is a desired feature, try to reload the line card. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_QOS-2-NOMEM: Memory Allocation Failure - [chars]: [chars] 
[dec] [dec] 

Explanation    The SIP 600 could not allocate the memory that is required for the QoS feature. This condition might indicate that more memory must be installed on the affected line card or platform to service all features and related entries that are enabled in the configuration.

Recommended Action    Determine the available memory, and install more if necessary. If sufficient memory is available, reload the Cisco IOS image on the affected line card or platform. If the error persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SIP600_QOS-3

Error Message    %SIP600_QOS-3-CLASSIFYUPDATE: SIP-600 Update QOS Classify Hardware 
Failed - [chars]: [chars] [dec] Cause: [hex] 

Explanation    The SIP 600 received an error on the specified hardware classify entry when attempting the specified action.

Recommended Action    If the error occurs when allocating any of the default classify entries, try to reload the line card and then verify that traffic can be forwarded out the line card. If the error occurs in all other cases, remove the QoS action that was just performed, wait a period of time, then reapply the service policy. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_QOS-3-EXCEEDEXCESSQRATE: SIP-600 Exceeded system maximum 
excess queue rates - [chars]: [chars] [dec] Cause: [hex] 

Explanation    The SIP 600 received an error on the specified hardware queue when attempting the specified action. This condition is the result of attempting to configure a QoS action. The sum of excess bandwidth for all allocated queues has exceeded the system limit.

Recommended Action    Remove the service policy that failed and try applying the shape command to each of the classes if they are not already configured. Then reapply the service policy. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_QOS-3-EXCEEDGUARTQRATE: SIP-600 Exceeded Guaranteed Rates on 
interface - [chars]: [chars] [dec] Cause: [hex] 

Explanation    The SIP 600 received an error on the specified hardware queue when attempting the specified action. This condition is the result of attempting to configure a QoS action. The sum of all queue guaranteed rates has exceeded the maximum that can be configured for the interface to which the queues are applied. This condition could be caused when the priority command is configured without the police command.

Recommended Action    Add the police command to limit the rate of the priority queue. If this is not the case, remove the service policy and reapply it. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_QOS-3-INSUFFDFLTBW: SIP-600 Insufficient bandwidth for default 
processing: port [dec] queue id [dec] Cause: [hex] 

Explanation    The SIP 600 reserves 1 percent of the bandwidth of a port for router control packets. When a service policy is applied, this bandwidth is first deducted from the QoS class-default queue. If there is not sufficient bandwidth in the class-default queue and the sum of queue guaranteed bandwidth exceeds the link rate, this message is generated instead of the EXCEEDGUARTQRATE message.

Recommended Action    Determine if there is any bandwidth available for class-default so that space is made available for the port's queue to handle control packets. Reduce the amount of bandwidth configured on user-defined classes so that more bandwidth is available for class-default. If necessary, explicitly configure bandwidth for class-default by entering the bandwidth command. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_QOS-3-NORESOURCE: SIP-600 Out of Resources- [chars]: [chars] 
[dec] Cause: [hex] 

Explanation    The specified resource has been depleted from the SIP 600.

Recommended Action    Change the SIP 600 configuration to conserve its use of the specified resource.

Error Message    %SIP600_QOS-3-NOTFOUND: SIP-600 Software Element Not Found - [chars]: 
[chars] [dec] 

Explanation    The SIP 600 client could not locate a required software element.

Recommended Action    Reload the Cisco IOS image on the affected line card or platform. If the error persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_QOS-3-NOTSUP: SIP-600 Feature Not Supported - [chars]: [chars] 
[chars] 

Explanation    The SIP 600 does not support the specified feature.

Recommended Action    Change the SIP 600 configuration so that it does not include the specified feature.

Error Message    %SIP600_QOS-3-QEXCEEDWREDGRP: SIP-600 Exceeded WRED limit groups for 
queue [dec] 

Explanation    The SIP 600 depleted available resources when configuring WRED on the specified hardware queue. This condition is the result of attempting to configure a QoS action.

Recommended Action    For each queue, there is a limited number of unique WRED limits sets that can be configured. The user-configuration action has caused the limits to go beyond the system limit. As a result, WRED is not configured on that queue. The following configuration illustrates three unique sets of WRED min/max limits:

random-detect
random-detect prec 0 1000 2000 1
random-detect prec 1 1000 2000 1
random-detect prec 2 2000 3000 1
random-detect prec 3 2000 3000 1
random-detect prec 4 1000 2000 1
random-detect prec 5 3000 4000 1
random-detect prec 6 2000 3000 1
random-detect prec 7 3000 4000 1

Update your configuration so that the WRED configuration is within the limits, and reapply the service policy.

Error Message    %SIP600_QOS-3-QUPDATE: SIP-600 Update Queue Hardware Failed - [chars]: 
[chars] [dec] Cause: [hex] 

Explanation    The SIP 600 received an error on the specified hardware queue when attempting the specified action. This condition is the result of attempting to configure a QoS action.

Recommended Action    There are a variety of reasons that this condition occurs: 1) If the user configuration action was to remove a service policy and then reapply a service policy to the same interface, it is possible that queues are still draining, which prevents new queues from being allocated. You need to remove the service-policy that failed, wait for a period of time, and then reapply the service policy. 2) It is possible that the number of resources has been depleted. You can consolidate your current QoS configuration to free up resources and then try reapplying your new configuration. 3) If the error was the result of removing queue hardware, then there is a hardware problem that must be reported. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SIP600_QOS-3-QWREDGTQLIMIT: SIP-600 WRED maximum threshold exceeds 
queue-limit for queue [dec] 

Explanation    The WRED maximum threshold values should be greater than the assigned queue limit. This condition is the result of the user attempting to configure WRED or changing bandwidth rates, which changes queue-limit values. If this error has occurred, the queue is allocated but WRED is not enabled.

Recommended Action    Make sure the queue-limits configured does not exceed any of the WRED max_threshold values. If the queue-limit command is not configured, configure one that is greater than WRED max_threshold values.

SIPSPA Messages

This section contains SPA messages on GSR line cards (SIPSPA).

SIPSPA-4

Error Message    %SIPSPA-4-MAX_BANDWIDTH_NS: Total SPA bandwidth exceeds line card 
capacity, full utilization of installed SPA interfaces is not supported 

Explanation    The total bandwidth of the SPAs exceeds the rated capacity of this line card.

Recommended Action    Refer to the line card guidelines for the maximum allowed aggregated SPA bandwidth for the line card.

SMSC_RP Messages

This section contains route processor messages for short message service centers (SMSC_RP).

SMSC_RP-3

Error Message    %SMSC_RP-3-GETHWVER_FAILED: Unable to set 7600-SSC-400 in slot [dec] 
in single-spa-mode because of error in obtaining its hardware revision. 

Explanation    The 7600-SSC-400 could not be set to single-SPA mode.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SMSC_RP-3-NO_SCP_BUFFER: Unable to set 7600-SSC-400 in slot [dec] in 
single-spa-mode because of insufficient scp buffers. 

Explanation    The 7600-SSC-400 could not be set to single-SPA mode.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SMSC_RP-3-SSC_SSPA_RETRY: 7600-SSC-400 in slot [dec] is reset as a 
[dec] try to set it in single-spa-mode. 

Explanation    The specified slot has reset in an attempt to set the 7600-SSC-400 in single-SPA mode. Reattempting to set the 7600-SSC-400 in single-SPA mode will occur three times.

Recommended Action    If the third reattempt is unsuccessful, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SMSC_RP-3-SSC_SSPA_SHUT: 7600-SSC-400 in slot [dec] is shutdown 
because it cannot be set in single-spa-mode 

Explanation    The specified slot has shut down because it could not be set in single-SPA mode.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SMSC_RP-6

Error Message    %SMSC_RP-6-INVALID_HW_VERSION: Single-spa-mode is not allowed for 
7600-SSC-400 hardware version [dec].[dec]. 

Explanation    Only 7600-SSC-400 versions greater than 0.3 can be set in single-SPA mode.

Recommended Action    To use single-SPA mode, use 7600-SSC-400 versions greater than 0.3.

SNMP Messages

This section contains Simple Network Management Protocol (SNMP) messages.

SNMP-5

Error Message    %SNMP-5-MODULERESET: [chars] object has been set to 'reset' for 
[chars]=[dec] from IP address [chars]. 

Explanation    The SNMP server has reset a module.

Recommended Action    No action is required.

SPA_CHOC_DSX Messages

This section contains common channelized Shared Port Adapter (SPA_CHOC_DSX) messages.

SPA_CHOC_DSX-3

Error Message    %SPA_CHOC_DSX-3-SEMAHOG: SPA on [chars]: Semaphore Hog was 
encountered.

Explanation    One process has failed to release the semaphore used by IPC communication between the host and the SPA. This behavior might cause other processes to fail to send commands down to the SPA. This condition might cause improper operation.

Recommended Action    Stop all traffic on the SPA and then reload the configuration by entering the shut/no shut command on the controllers. If the problem persists, power cycle the SPA.

Error Message    %SPA_CHOC_DSX-3-SPA_SW_ERR: SPA on [chars]: [chars] Software error was 
encountered.

Explanation    The SPA driver detected a software error on the SPA. This condition might result in improper operation.

Recommended Action    Reload the configuration by entering the shut/no shut command on the controllers. If the problem persists, power cycle the SPA.

Error Message    %SPA_CHOC_DSX-3-SPI4_HW_ERR: SPA on [chars]: [chars] Hardware error 
was encountered.

Explanation    The SPA driver detected a hardware error on the SPA. This condition might result in improper operation.

Recommended Action    Power down and reseat the indicated SPA line card.

SPA_T3E3 Messages

This section contains T3E3 (SPA_T3E3) messages.

SPA_T3E3-3

Error Message    %SPA_T3E3-3-SSBINIT: [chars]: Fail to initialize serial IDB 

Explanation    The system failed to initialize the serial IDB. The probable cause is a lack of system memory. Earlier messages might indicate memory allocation failures.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SPA_T3E3-3-SUBRATE_FPGA_LOAD_FAILED2: [chars] Programming [chars] 
subrate FPGA failed again. The SPA will be disabled as it cannot recover from the 
FPGA image corruption. 

Explanation    The specified subrate FPGA image is corrupted after an FPD upgrade. This condition might indicate an FPD image package problem. The SPA is disabled until this problem is corrected.

Recommended Action    Verify the correctness of the FPD image package. Note that the FPD image package used in the upgrade should match the Cisco IOS release that is operating on the module. A match between the two can be verified by entering the show upgrade fpd package default command.

SPAN Messages

This section contains Switched Port Analyzer (SPAN) messages.

SPAN-3

Error Message    %SPAN-3-SESS_DEC_CFG: SPAN hardware resource is in use. [chars] 

Explanation    The system could not allocate a SPAN hardware resource for the feature specified in the error message. It is possible that a distributed EtherChannel has been configured in the system and that it is using the SPAN hardware resource.

Recommended Action    Remove one or all of the distributed EtherChannels from the system, and retry the operation.

Error Message    %SPAN-3-SESS_HW_UNAVAIL: SPAN hardware resource not available [chars] 

Explanation    The system could not allocate a SPAN hardware resource for the feature specified in the error message. A possible cause of this condition is that all available SPAN source sessions are already in use. The system can be configured with a maximum of two SPAN source sessions or one RSPAN source session.

Recommended Action    Remove one of the existing SPAN or RSPAN source sessions, and retry the operation.

SPANTREE Messages

This section contains Spanning Tree (SPANTREE) messages.

SPANTREE-3

Error Message    %SPANTREE-3-PRESTD_NEIGH: pre-standard MST interaction not configured 
([chars]). Please, configure: 'spanning-tree mst pre-standard' on ports connected 
to MST pre-standard switches. 

Explanation    The switch has received a prestandard MST BPDU on a port that is not configured for prestandard MST BPDU transmission. The switch will automatically adjust its mode of operation on this port and will start sending prestandard BPDUs. This auto-detection of prestandard neighbors is not always completely accurate, so we recommend that you configure the port for prestandard MST BPDU transmission. This warning message will display only once.

Recommended Action    Configure the spanning-tree mst pre-standard command on all the ports that are connected to switches running Cisco's prestandard version of MST. We recommend that you migrate all switches in the network to the IEEE standard MST version when possible.

SPANTREE-6

Error Message    %SPANTREE-6-PORTADD_ALL_VLANS: [chars] added to all Vlans 

Explanation    The specified interface has been added to all VLANs.

Recommended Action    No action is required.

Error Message    %SPANTREE-6-PORTDEL_ALL_VLANS: [chars] deleted from all Vlans 

Explanation    The specified interface has been deleted from all VLANs.

Recommended Action    No action is required.

Error Message    %SPANTREE-6-PORT_STATE: Port [chars] instance [dec] moving from 
[chars] to [chars] 

Explanation    The state of the specified Spanning Tree port has changed.

Recommended Action    No action is required.

SPANTREE-7

Error Message    %SPANTREE-7-PORTDEL_SUCCESS: [chars] deleted from Vlan [dec] 

Explanation    The specified interface has been deleted from the specified VLAN.

Recommended Action    No action is required.

SPLITVLANM Messages

This section contains Split VLAN Manager (SPLITVLANM) messages.

SPLITVLANM-2

Error Message    %SPLITVLANM-2-ERROR: [chars] [chars]:[dec] 

Explanation    This message provides information about a software error.

Recommended Action    Copy the error message exactly as it appears, and report the error to your technical support representative.

SPLITVLANM-3

Error Message    %SPLITVLANM-3-ERROR_STAT: [chars] stat:[dec] in [chars]:[dec] 

Explanation    This message provides information about a software error.

Recommended Action    Copy the error message exactly as it appears, and report the error to your technical support representative.

SPLITVLANM-4

Error Message    %SPLITVLANM-4-WARNING : [chars] [chars]:[dec] 

Explanation    This message provides information about a software warning.

Recommended Action    Copy the warning message exactly as it appears, and report it to your technical support representative.

SPLITVLANM-6

Error Message    %SPLITVLANM-6-FPM_DISABLED: feature disabled on [chars] direction of: 
[chars] 

Explanation    Flexible Packet Matching (FPM) is disabled, and traffic is not directed to the PISA.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %SPLITVLANM-6-FPM_ENABLED: feature accelerated on [chars] direction 
of: [chars] 

Explanation    Flexible Packet Matching (FPM) is enabled, the feature is accelerated, and all traffic is directed to the PISA.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %SPLITVLANM-6-NBAR_DISABLED: feature disabled on [chars] direction of: 
[chars] 

Explanation    NBAR is disabled, and traffic is not directed to the PISA.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %SPLITVLANM-6-NBAR_ENABLED: feature accelerated on [chars] direction 
of: [chars] 

Explanation    NBAR is enabled, the feature is accelerated, and all traffic is directed to the PISA.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %SPLITVLANM-6-NBAR_PD_DISABLED: Protocol Discovery disabled on [chars] 
direction of: [chars] 

Explanation    NBAR protocol discovery is disabled, and traffic is not directed to the PISA.

Recommended Action    No action is required. This message is for informational purposes only.

Error Message    %SPLITVLANM-6-NBAR_PD_ENABLED: Protocol Discovery accelerated on 
[chars] direction of: [chars] 

Explanation    NBAR protocol discovery is enabled, the feature is accelerated, and all traffic is directed to the PISA.

Recommended Action    No action is required. This message is for informational purposes only.

SSA Messages

This section contains Super Santa Ana ASIC (SSA) messages.

SSA-4

Error Message    %SSA-4-FABRICCRCERRS: [dec] Fabric CRC error events in 100ms period 

Explanation    The SSA fabric interface encountered more CRC error events than the supervisor engine CRC error threshold allows.

Recommended Action    The module has notified the supervisor engine, and the error has been logged. No action is required.

Error Message    %SSA-4-FABRICSYNCERRS: [dec] Fabric sync error events in 100ms period 

Explanation    The SSA fabric interface encountered more synchronization error events than the supervisor engine synchronization error threshold allows.

Recommended Action    The module has notified the supervisor engine, and the fabric interface will be resynchronized. No action is required.

SSA-5

Error Message    %SSA-5-NOFABRICPROCESS: The Super Santa Ana fabric process could not 
be created 

Explanation    The SSA fabric interface does not have a link process running because the system failed to create it. This module will not support the fabric interface.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SSA-5-NULL_SSA_OBJECT: The Super Santa Ana device object pointer is 
set to NULL 

Explanation    The memory location of the SSA device object is invalid. The SSA ASIC operation is disabled, and the device interrupt is now masked.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SSA-5-SMB_ACCESSERROR: The Module Super Santa Ana ASIC cannot be 
accessed 

Explanation    The SSA ASIC read and write access failed. The serial bus that is connected to the SSA ASIC on this module is not functioning correctly.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SSA-5-SSA_INIT_FAILURE: The Super Santa Ana ASIC initialization 
failed 

Explanation    The SSA ASIC could not be initialized. As a result, this device is not operational and has been disabled.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SSP Messages

This section contains State Synchronization Protocol Manager (SSP) messages.

SSP-3

Error Message    %SSP-3-DATACREATEFAIL: Creation of required data structures failed. 

Explanation    The SSP will not operate properly due to the abnormal initialization of required data structures.

Recommended Action    Reload the device. If the error persists, contact your technical service representative.

Error Message    %SSP-3-EXCEEDMAXDOI: SSP maximum DOI exceeded. 

Explanation    The configuration has exceeded the maximum number of SSP clients allowed on this device at any one time.

Recommended Action    Verify your configuration and reduce the number of SSP clients running at the same time. If a large number of SSP clients is required, contact your technical service representative for assistance.

Error Message    %SSP-3-NOSTART: SSP could not initialize. 

Explanation    The SSP process could not successfully initialize. This condition might be caused by unusual protocol startup times in certain topologies.

Recommended Action    Ensure that your IP redundancy mechanism (HSRP) configuration is valid and that all protocols have started. Try to configure SSP again. If this error recurs, contact your technical support representative.

Error Message    %SSP-3-SRVSOCKCREATEFAIL: SSP socket creation failed. 

Explanation    The SSP process could not establish a socket connection with the SSP peer. This condition is likely to occur because either the device is under extreme load or it is misconfigured.

Recommended Action    Verify that the SSP configuration is valid. Configure SSP to use a different port number. Reduce the load on the device.

SSP-4

Error Message    %SSP-4-CANNOTRUNVER: SSP version [dec].[dec] was requested but is not 
supported in this image. 

Explanation    The version of SSP requested by the active device is not available in this image. SSP will not run on this device until it is upgraded or the active device is downgraded.

Recommended Action    Verify that all SSP peers are running compatible images and that the configuration on each device is correct.

Error Message    %SSP-4-GROUPCREATEFAIL: The SSP group could not be created.

Explanation    The maximum number of SSP groups has been reached. Only one SSP group is permitted at one time.

Recommended Action    No action is required.

Error Message    %SSP-4-MISMATCHEDVERRECV: Wrong version on received packet.

Explanation    The SSP version information in a received packet does not match the version that is currently running on this device.

Recommended Action    Verify the configuration of all the SSP peers. Ensure that all peers are running the correct image.

SSP-5

Error Message    %SSP-5-DISABLED: SSP entering disabled state. 

Explanation    The SSP has entered the disabled state. This condition is normal under many circumstances. An example of a normal condition is when the SSP configuration is changed or when a tracked interface is shut down or fails.

Recommended Action    If this change occurred because of failure on the active peer, eliminate the cause of failure and reload the failed device.

SSP-6

Error Message    %SSP-6-ACTIVE: SSP entering active state. 

Explanation    The SSP has entered the active state.

Recommended Action    No action is required.

Error Message    %SSP-6-IPREDGRPADD: An IP Redundancy group listed in the SSP config 
has been added to this device. 

Explanation    The device might now become the active device or the redundant device if no other configuration items are missing.

Recommended Action    No action is required.

Error Message    %SSP-6-IPREDGRPDEL: An IP Redundancy group listed in the SSP config 
has been removed from this device. 

Explanation    The device might not become the active device or the redundant device if any configuration items are missing.

Recommended Action    Add the IP redundancy group to the device, or remove it from the SSP configuration.

Error Message    %SSP-6-STANDBY: SSP entering standby state. 

Explanation    The SSP has entered standby state.

Recommended Action    No action is required.

STAPL Messages

This section contains Standard Test and Programming Language (STAPL) messages.

STAPL-4

Error Message    %STAPL_OPEN-4-ERROR_ALLOC: %Error: Can't allocate [dec] bytes for 
STAPL data 

Explanation    The system could not allocate the required memory to access the file.

Recommended Action    Check the memory usage of the system, and retry the operation.

Error Message    %STAPL_OPEN-4-ERROR_OPEN: %Error: Can't open [chars] 

Explanation    The system is unable to open the file specified in the error message.

Recommended Action    Ensure that the filename is correct. Enter the dir command to verify the filename.

Error Message    %STAPL_OPEN-4-ERROR_READ: %Error: STAPL file [chars] read failed 

Explanation    An unknown error occurred while the system was copying the STAPL program file to a local buffer.

Recommended Action    Enter the del [chars] command to remove the file. Use the copy command to recopy the file from a known good source to its desired destination [chars]. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %STAPL_OPEN-4-ERROR_SIZE: %Error: Bad file size [chars] 

Explanation    The file is too small or too large for a STAPL program file.

Recommended Action    Enter the dir command, determine the size of the file, and retry the operation.

SVCLC Messages

This section contains service line card (SVCLC) messages.

SVCLC-2

Error Message    %SVCLC-2-MAJORTEMP: Module [dec] CPU[dec] has exceeded its allowed 
operating temperature. (current temp=[dec]C)  Module will be shut down immediately 

Explanation    The specified service line card in the system has sent a thermal shutdown request to the supervisor engine. The first [dec] is the module number, the second [dec] is the CPU number, and the third [dec] is the temperature.

Recommended Action    Determine if the environment is too hot. If the environment is not too hot, replace the hardware.

SVCLC-4

Error Message    %SVCLC-4-MINORTEMP: Module [dec] CPU[dec] has exceeded its normal 
operating temperature. (current temp=[dec]C) 

Explanation    The specified CPU on the specified service line card is too hot. The first [dec] is the module number, the second [dec] is the CPU number, and the third [dec] is the temperature.

Recommended Action    Determine if the environment is too hot. If the environment is not too hot, replace the hardware.

Error Message    %SVCLC-4-TEMPRECOVER: Module [dec] CPU[dec] has returned to its normal 
operating temperature. (current temp=[dec]C) 

Explanation    The specified service line card in the system has sent a thermal recovery event to the supervisor engine. The first [dec] is the module number, the second [dec] is the CPU number, and the third [dec] is the temperature.

Recommended Action    No action is required.

SW_VLAN Messages

This section contains VLAN manager (SW-VLAN) messages.

SW_VLAN-4

Error Message    %SW_VLAN-4-MAX_SUB_INT: The number of sub-interfaces allocated for 
interface [chars] has exceeded recommended limits of [dec] 

Explanation    The number of subinterfaces allocated for the interface has exceeded the recommended limit.

Recommended Action    Reduce the number of subinterfaces allocated for the interface to within the recommended limit.

Error Message    %SW_VLAN-4-VLAN_CREATE_FAIL: Failed to create VLANs [chars]: [chars] 

Explanation    The VLANs specified in the error message could not be created. The VLAN manager called a VLAN database routine to create one or more VLANs, but the PM failed to create the requested VLANs. A possible cause of this error is that the VLANs already exist in the PM as internal VLANs.

Recommended Action    Determine the internal VLAN usage by entering the show vlan internal usage command. Unconfigure the feature that occupies the internal VLAN, and retry the VLAN creation operation. If this condition recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SW_VLAN-4-VTP_DB_INVALID_VLANID: Invalid VLAN ID [dec] found in VTP 
database download 

Explanation    An invalid VLAN ID was detected in the VTP database during the download of the VTP configuration file. This condition indicates that the VTP configuration file in NVRAM is corrupted. [dec] is the VLAN ID.

Recommended Action    Save a copy of the vlan.dat file that includes the invalid VLAN ID to help investigate the condition. Collect the output from the show vtp status command and the show vlan command. Contact your Cisco technical support representative with the information that you have collected.

Error Message    %SW_VLAN-4-VTP_SEM_BUSY: VTP semaphore is unavailable for function 
[chars]. Semaphore locked by [chars] 

Explanation    The VTP database is currently locked by another task and is not available.

Recommended Action    Retry the operation later. If this condition recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SYS Messages

This section contains operating system (SYS) messages.

SYS-4

Error Message    %SYS-4-GREEDY_REGEXP: [chars] while processing the input regular 
expression. Aborting processing, use alternate regular expression. Input regular 
expression: "[chars]" 

Explanation    The specified regular expression requires excessive resources for processing. To avoid processing timeouts or an unexpected reload, the processing was aborted.

Recommended Action    Use a different regular expression.

SYS-5

Error Message    %SYS-5-NV_LOCK_EBUSY: Failed to acquire nvram lock at [chars]:[dec]. 
REQ path: [chars] pid:[dec] proc: [chars] RFS client:[dec] c/s:[dec]/[dec] 
mode:[dec]. OWN nv_ifs_path: [chars] proc: [chars] RFS client:[dec] 
c/s:[dec]/[dec] rfs_ac:[dec]. nv_ifs_pid:[dec] local_lock:[dec] rfs_lock:[dec] 
last_req:[dec] nv_fs_ac:[dec] nv_ifs_trace: [chars] 

Explanation    A request to access NVRAM has failed because the NVRAM is locked by another application. The NVRAM can serve only one application request at a time.

Recommended Action    This message can be ignored if it is seen only occasionally or during bootup, when the NVRAM might be locked by another application. If this message is seen for all NVRAM access requests (such as write memory or dir nvram), then Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

SYS-7

Error Message    %SYS-7-NV_LOCK_EACCES: Failed to acquire/release nvram lock at 
[chars]:[dec]. REQ path: [chars] pid:[dec] proc: [chars] RFS client:[dec] 
c/s:[dec]/[dec] mode:[dec]. OWN nv_ifs_path: [chars] proc: [chars] RFS 
client:[dec] c/s:[dec]/[dec] rfs_ac:[dec] nv_ifs_pid:[dec] local_lock:[dec] 
rfs_lock:[dec] last_req:[dec] nv_fs_ac:[dec] nv_ifs_trace: [chars] 

Explanation    A request to release NVRAM has failed.

Recommended Action    This message can be ignored if it is seen during a switchover, reload, or bootup. If this message is seen under normal conditions, Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.

SYS_CONTROLLER Messages

This section contains system controller (SYS_CONTROLLER) messages.

SYS_CONTROLLER-3

Error Message    %SYS_CONTROLLER-3-CREATE_IBC_FAILED: Creation of ibc idb failed 

Explanation    The IBC IDB creation has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SYS_CONTROLLER-3-INIT_IBC_FAILED: Initialization of ibc failed 

Explanation    IBC initialization has failed.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SYS_CONTROLLER-3-INIT_ICDM_FAILED: Initialization of icdm driver 
failed 

Explanation    ICMD driver initialization failed for IBC.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SYS_CONTROLLER-3-INIT_MAC_DRIVER_FAILED: Initialization of ethernet 
mac driver failed 

Explanation    Ethernet MAC driver initialization failed for IBC.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SYS_CONTROLLER-3-MASKED_RCV_INTR: ibc_rcv_interrupt called while 
masked: [int] 

Explanation    A software error occurred. An IBC receive interrupt was received despite being masked.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SYS_CONTROLLER-3-NO_BUFFER_POOLS: Initialization of private buffer 
pools failed 

Explanation    Private buffer pools were not created for IBC.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SYS_CONTROLLER-3-NO_PARTICLE: no particle available to populate the 
ethernet dma ring 

Explanation    No particle is available to populate the Ethernet DMA ring.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %SYS_CONTROLLER-3-RX_ADD_BUFFER_FAILED: particle not added to the 
ethernet dma ring 

Explanation    The particle was not added to the Ethernet DMA ring.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

SYSMGR Messages

This section contains system manager (SYSMGR) messages.

SYSMGR-6

Error Message    %SYSMGR-6-RESTART: Restarting process [chars] by [chars] 

Explanation    A process was restarted using the CLI.

Recommended Action    This is an informational message. No action is required.

TCP Messages

This section contains Transmission Control Protocol (TCP) messages.

TCP-3

Error Message    %TCP-3-BADMSS: Incorrect mss [dec] observed 

Explanation    The maximum segment size (MSS) is incorrect, and reliable operation for this connection cannot be guaranteed.

Recommended Action    Increase the interface MTU. If increasing the MTU does not help, contact your technical support representative for assistance.

Error Message    %TCP-3-FORKFAIL: Failed to start a process to negotiate options. 

Explanation    The system failed to create a process to handle requests from a client. This condition could be caused by insufficient memory.

Recommended Action    Reduce other system activity to ease memory demands.

TFIB Messages

This section contains Tag Forwarding Information Base (TFIB) messages.

TFIB-3

Error Message    %TFIB-3-TAGTYPEMISMATCH: Existing tag type [dec], Incoming tag type 
[dec] 

Explanation    The tag type of incoming tag_rewrites does not match the tag type of existing tag_rewrites.

Recommended Action    Copy the message exactly as it appears, and report it to your technical support representative.

TRANGE Messages

This section contains time-range (TRANGE) messages.

TRANGE-2

Error Message    %TRANGE-2-NOMEMORY: Alloc fail for time-range config buffer. Disabling 
distributed mode on lc 

Explanation    The system is unable to allocate a buffer to send a time-range configuration to the linecards.

Recommended Action    Collect the output from a show chunks command. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %TRANGE-2-WRONGREQUEST: Invalid request to allocate chunk of size 
[dec] 

Explanation    A request to allocate a time-range chunk was denied because it exceeded the maximum size TRANGE_LARGE_CHUNK_SZ.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %TRANGE-2-WRONGSIZE: Incorrect length trange ipc xdr of len=[dec] 
received 

Explanation    The route processor sent a time-range configuration message of the wrong length.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

TRANSCEIVER Messages

This section contains transceiver (TRANSCEIVER) messages.

TRANSCEIVER-3

Error Message    %TRANSCEIVER-3-INTERNAL_ERROR: [chars] 

Explanation    The transceiver subsystem encountered an internal software error. The error message contains text that can be used to help identify the nature of the problem.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

UNICAST_FLOOD Messages

This section contains unicast flooding (UNICAST_FLOOD) messages.

UNICAST_FLOOD-4

Error Message    %UNICAST_FLOOD-4-DETECTED: Host [enet] on vlan [dec] is flooding to an 
unknown unicast destination at a rate greater than/equal to [dec] Kfps 

Explanation    A host was found going up and down between ports.

Recommended Action    Verify the reason why the host is sending traffic to an unknown unicast destination.

Error Message    %UNICAST_FLOOD-4-FILTER_TABLE_FULL: The filter table is full 

Explanation    The system has detected too many unicast floods to unknown destinations.

Recommended Action    Investigate the reason why so many hosts in the network are sending traffic to unknown unicast destinations.

UNICAST_FLOOD-5

Error Message    %UNICAST_FLOOD-5-FILTER_INSTALLED: Filter for host [enet] has been 
installed. It will be removed in [dec] minute(s) 

Explanation    A host was flooding unicast packets to an unknown destination. A filter has been installed.

Recommended Action    No action is required.

URLF Messages

This section contains URL filtering (URLF) messages.

URLF-3

Error Message    %URLF-3-ALLOW_MODE: Connection to all the URL filter servers are down 
and the allow mode is '[chars]' 

Explanation    No URL filter servers are available. If the allow mode is on, the router will pass HTTP traffic; otherwise, the router will drop HTTP traffic and close the TCP connection.

Recommended Action    Check the status of the URL filter server (WebSense/N2H2). Restart the server if necessary. If the server cannot be recovered, install another URL filter server and configure the new server location on the router.

Error Message    %URLF-3-MAX_REQ: The number of pending request exceeds the maximum 
limit [dec] 

Explanation    The number of pending URL authentication requests from the URL filter server exceeds the maximum limit. As a result, HTTP requests will be dropped.

Recommended Action    No action is required.

Error Message    %URLF-3-RESOURCE_ALLOC_FAILED: The resource allocation failed for URL 
filter subsystem 

Explanation    The URL filtering feature is unable to allocate memory for various data structures.

Recommended Action    Disable unused features or check for other reasons why the router may be running out of memory.

Error Message    %URLF-3-SERVER_DOWN: Connection to the URL filter server [IP_address] 
is down 

Explanation    The connection between the router and a URL filter server is down. If multiple servers are configured, the router will try another server for URL authentication. If no URL filter server is available, the router will check the allow mode. If the allow mode is 'on,' the router will pass HTTP traffic; otherwise, the router will drop HTTP traffic and close the TCP connection.

Recommended Action    Check the status of the URL filter server (WebSense/N2H2). Restart the server if necessary. If the server cannot be recovered, install another URL filter server and configure the new server location on the router.

Error Message    %URLF-3-URL_TOO_LONG: URL sent from [IP_address] is too long (more than 
[dec] bytes), possibly a fake packet? 

Explanation    The URL in the HTTP GET request is too long. Because the packet may be fake, it will be dropped.

Recommended Action    No action is required.

URLF-4

Error Message    %URLF-4-SITE_BLOCKED: Access denied for the site '[chars]', client 
[IP_address]:[dec] server [IP_address]:[dec] 

Explanation    A user attempted to browse a forbidden site. All underlying URLs of the indicated domain are blocked from access.

Recommended Action    No action is required.

Error Message    %URLF-4-URL_BLOCKED: Access denied URL '[chars]', client 
[IP_address]:[dec] server [IP_address]:[dec] 

Explanation    A user attempted to browse a forbidden site. Access to the requested URL is denied and the corresponding TCP connection is closed.

Recommended Action    No action is required.

URLF-5

Error Message    %URLF-5-SERVER_UP: Connection to an URL filter server([IP_address]) is 
made, the router is returning from ALLOW MODE 

Explanation    At least one URL filter server is now available. The router will return to normal operation from allow mode.

Recommended Action    No action is required.

URLF-6

Error Message    %URLF-6-SITE_ALLOWED: Client [IP_address]:[dec] accessed server 
[IP_address]:[dec] 

Explanation    All URLs belonging to the indicated server address are allowed to be accessed without URL filtering authentication.

Recommended Action    No action is required. This message can be used to track the number of GET requests sent from a client to the server.

Error Message    %URLF-6-URL_ALLOWED: Access allowed for URL '[chars]', client 
[IP_address]:[dec] server [IP_address]:[dec] 

Explanation    An HTTP GET request from a client is allowed to be transmitted to the indicated server.

Recommended Action    No action is required.

VPN_HW Messages

This section contains VPN Hardware Accelerator for IPsec (VPN_HW) messages.

VPN_HW-1

Error Message    %VPN_HW-1-ALIGN: Slot: [dec] - Alignment failure on packet buffer: 
[hex] 

Explanation    A software error has occurred. The VPN hardware accelerator driver has detected that the buffer is not aligned correctly.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPN_HW-1-ERROR: slot: [dec] - [chars] 

Explanation    An error occurred in the application that was using the VPN hardware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPN_HW-1-HEARTBEAT: VPN Module in slot: [dec]: Keepalive lost. 

Explanation    Keepalive messages have been lost, indicating that the VPN hardware accelerator is no longer operating.

Recommended Action    Reboot your router. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPN_HW-1-INITFAIL: Slot [dec]: [chars] 

Explanation    The VPN hardware accelerator driver could not initialize the accelerator at the slot specified in the error message at the specified point.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPN_HW-1-NOMEMORY: [chars] creation failed for slot [dec] 

Explanation    During its initialization phase, the VPN hardware driver could not allocate memory for the data structure that is specified in the error message.

Recommended Action    Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. If this message recurs, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPN_HW-1-OWNER: slot: [dec]: [chars] packet buffer, pak=[hex] 

Explanation    A software or hardware error has occurred. The VPN hardware accelerator driver has detected that the buffer ring is in an inconsistent and unrecoverable state.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPN_HW-1-PACKET_ERROR: slot: [dec] Packet Encryption/Decryption 
error, [chars] 

Explanation    An unexpected error occurred during the encryption or decryption of a packet.

Recommended Action    This message can occur occasionally during normal operation of the system. It may occur during the transition to a new session key for a Security Association. In such cases, no action is required. However, if it happens frequently, or is associated with traffic disruption, then note the status value and contact your Cisco technical support representative. The VPN hardware accelerator will most likely need to be replaced.

Error Message    %VPN_HW-1-TOOBIG: Slot: [dec] - [chars] received a packet with size 
[dec]. 

Explanation    The MTU size has been exceeded.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPN_HW-1-UNSUPP: VPN Module in slot: [dec]: [chars] ([hex]). 

Explanation    This revision or version of the VPN hardware accelerator in the slot specified in the error message is not supported.

Recommended Action    Verify that the VPN hardware adapter is the proper hardware level and software revision for the running version of the Cisco IOS software. If it is, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

VPN_HW-3

Error Message    %VPN_HW-3-MULTDEV: Cannot support more than one Encryption AIM 

Explanation    A second Encryption AIM was discovered present in the system. The Encryption AIM software only supports a single Encryption AIM. All other Encryption AIMs installed will be ignored.

Recommended Action    Remove one of the Encryption AIMs that are installed in your system.

VPN_HW-6

Error Message    %VPN_HW-6-INFO: slot: [dec] [chars] 

Explanation    This is informational message from the VPN hardware accelerator driver.

Recommended Action    This message occurs during normal system operation. No action is required.

Error Message    %VPN_HW-6-SHUTDOWN: [chars] shutting down 

Explanation    The specified VPN hardware is shutting down. It may have been physically removed.

Recommended Action    This message occurs during normal system operation. No action is required.

VPNSM Messages

This section contains Virtual Private Network Services Module (VPNSM) messages.

VPNSM-3

Error Message    %VPNSM-3-ACEI0BADPARAM: PcpManCreateTunn: cannot create tunnel with 
expiring Sa

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI0TCAMFAILED: SpdSpInstall: cannot install Sp [dec]: 
TmInsertSp failed 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI1BADPARAM: SpdSpInstall: cannot install generic SP [dec] 
with non-zero priority 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI1OUTOFSA: PcpQOpCreSaBegin: cannot create new Sa using 
SpdMan 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI10OUTOFCME: PcpManCreateAcl: cannot allocate new Acl for 
aclId=[int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI11NESTOVERFLOW: SpdSaAddTmInsCb: cannot have more than 
[dec] pending nested callbacks from TcamMan 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI11OUTOFSEL: PcpAclGetSpSelSet: cannot clone SelSet for 
ACL [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI12IDNOTINUSE: PcpManRemoveAcl: cannot remove 
non-existing access list [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI12OUTOFSAPAR: SpdSaSetKeys: cannot allocate new SaPar for 
Sa [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI13IDINUSE: PcpManRemoveAcl: cannot remove access list 
[int] while in use 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI14BADCMEID: PcpSpdCreateCme: cannot create Cme with 
ID=[dec]: too large 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI14NOLOGA: SpdSaSetParams: cannot allocate SPI with 
TcamMan for Sa [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI15IDNOTINUSE: PcpManRemoveCme: cannot remove 
non-existing Cme [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI16BADPARAM: PcpManActivateFlowAsync: cannot activate 
flow [dec]: Sa is in the wrong state 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI16TCAMFAILED: SpdSaTmInstallIn: cannot install inbound Sa 
[dec] with TcamMan 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI17BADPARAM: PcpManActivateFlowAsync: cannot activate 
non-existing flow [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI17TCAMFAILED: SpdSaTmInstallOut: cannot install outbound 
Sa [dec] with TcamMan 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI18BADPARAM: PcpManCreateSMap: cannot create outbound SPD 
Map [int] with ingress access list [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI19BADCMEID: PcpManActivateFlowAsync: cannot activate 
flow [dec] with non-existing Cme [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI2BADPARAM: PcpManUpdateFlow: cannot update flow [dec] 
with invalid ID 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI2NESTOVERFLOW: SpdSaInitTmSaOut: outer outbound Sa [dec] 
of Sa [dec] is above nesting limit of [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI20OUTOFSEL: PcpUtilSelSetFromPar: cannot allocate new 
selector set 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI21BADPARAM: PcpAclAppend: got too many denys for 
aclId=[dec], max is [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI22BADPARAM: PcpAclAppend: got out-of-sequence line number 
[dec] for aclId=[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI23IDINUSE: PcpSpdCreateCme: cannot create Cme with 
ID=[int]: already used 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI24BADPARAM: PcpAclAppend: got invalid ranges for selector 
set at lineNo=[dec], aclId=[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI25IDINUSE: PcpAclAppend: got duplicate line number [dec] 
for aclId=[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI26OUTOFSP: PcpCmeInstallNext: cannot create a new Sp 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI27BADPARAM: PcpManSetFlowKeys: cannot set keys for flow 
[dec]: SA is in the wrong state 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI28IDINUSE: PcpQOpCreSaBegin: cannot create second Sa for 
flow [dec]: conditions for transport adj. are not met 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI29SPDFAILED: PcpCmeInstallNext: cannot install Sp [dec] 
with SpdMan 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI3NESTOVERFLOW: SpdSaGetXformSeq: outer inbound Sa [dec] 
of Sa [dec] is above nesting limit of [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI3OUTOFSEL: PcpQOpActSaBegin: cannot allocate selector set 
for outer Sa in flowId [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI30BADPARAM: PcpSpdUpdateCme: cannot update already queued 
Cme [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI31BADALENUM: PcpQOpActSaBegin: cannot find access list 
entry number [dec] for cmeId=[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI32BADPARAM: PcpQOpActSaBegin: cannot delete old 
[chars]bound flow [dec] while activating [chars]bound flow [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI33BADPARAM: PcpCmeActivateSa: got invalid lifetime values 
softSecs=[int], hardSecs=[int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI34BADPARAM: PcpCmeActivateSa: got invalid lifetime values 
softKBytes=[int], hardKBytes=[int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI35BADPARAM: PcpCmeIntersectSaWithSp: cannot activate 
flow [dec] with selector ranges not intersecting parent Sp 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI36BADSELADDR: PcpQOpActSaBegin: cannot activate per-host 
flow [dec] with addresses [dec].[dec].[dec].[dec] and [dec].[dec].[dec].[dec] not 
included in Sp [dec] selector sets 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI37OUTOFSEL: PcpQOpActSaBegin: cannot clone selector set 
to activate per-host flow [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI38BADSELADDR: PcpQOpActSaBegin: cannot activate 
transport mode flow [dec] with addresses [dec].[dec].[dec].[dec] and 
[dec].[dec].[dec].[dec] not included in Sp's selector sets 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI39BADPARAM: PcpTrInProcess: got invalid opcode [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI4BADPARAM: PcpQOpCreSaBegin: got invalid addresses 
[int].[int].[int].[int] and [int].[int].[int].[int] for other Sa of flow [dec]: 
expected [int].[int].[int].[int] and [int].[int].[int].[int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI40BADACLID: PcpManCreateCme: cannot create Cme with 
non-existing access list [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI41SPDFAILED: PcpQOpSaActivated: cannot finish activating 
Sa [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI42QUEUEFULL: PcpCmeActivateSa: cannot activate Sa [dec]: 
queue is full 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI43BADPARAM: PcpAclAppend: got invalid line number [dec] 
for ACL [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI44QUEUEFULL: PcpSpdCreateCme: cannot create Cme [int] 
(aclId=[int]): queue is full 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI45IDNOTINUSE: PcpManDestroyFlowAsync: cannot delete 
already deleted flow [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI46BADPARAM: PcpQOpActSaBegin: cannot activate 
non-fully-specified Sa for Cme [dec] without Acl 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI47BADPARAM: PcpQOpActSaBegin: cannot activate Sa for 
manual Sp (cmeId=[dec],entry=[dec]), Sa already exists 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI48CMEINUSE: PcpManSetInitMode: cannot set fast init-mode 
in TcamMan: [dec] pending Ops, [dec] Flows and [int] Cmes already exist or TcamMan 
is busy 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI49BADPARAM: PcpManQueryFlow: cannot query flow [dec]: Sa 
is not active 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI5BADPARAM: SpdSaActivate: cannot activate Sa [dec], old 
Sa [dec] already has successor Sa [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI5OUTOFSA: PcpQOpCreSaBegin: cannot create new Sa for flow 
[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI50CMEINUSE: PcpQOpRemCmeBegin: cannot remove Cme [dec]: 
TcamMan is in Init mode 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI51BADPARAM: PcpSpdCreateCme: got invalid flags 
(manual,dynamic,discover,drop,clear) = ([dec],[dec],[dec],[dec],[dec]), 
cmeId=[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI52IDINUSE: PcpManCreateAcl: cannot process opcode [int] 
for Acl [int] in state [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI53BADPARAM: PcpManCreateAcl: cannot create Acl with id 
[int] out of range [0,[int]] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI54CMENOTREADY: PcpSpdCreateCme: cannot create Cme [int] 
with Acl [int] when Acl state is [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI55SPDFAILED: PcpQOpActSaBegin: cannot begin activating Sa 
[dec] for flowId [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI56IDNOTINUSE: PcpManDestroyFlowAsync: cannot delete flow 
[dec] already being deleted 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI57CMEINUSE: PcpManSetInitMode: cannot set normal 
init-mode in TcamMan: there are pending Flows or Cmes 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI58IDNOTINUSE: PcpManDestroyFlowAsync: flow [dec] already 
queued for deletion 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI59BADPARAM: PcpCmeActivateSa: cannot activate flow [dec] 
as per-host with subset of Sp as a selector set 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI6OUTOFSEL: SpdSpInstall: cannot compute SP's 
permit-SelSets from mixed SelSet list 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI60SPDFAILED: PcpManSaUpdateError: cannot update Flow 
[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI61BADPARAM: PcpQOpActSaBegin: cannot activate Sa for 
cmeId=[dec], entry=[dec] with bad spdId=[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the error message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information.

Error Message    %VPNSM-3-ACEI62IDINUSE: PcpQOpCreSaBegin: cannot setup Flow [dec] in 
trans.adj. with outer SA in tunnel mode 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI63CMEINUSE: PcpManActivateFlowAsync: cannot activate 
flow [dec] while using fast policy mode 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI64BADPARAM: PcpQOpActSaBegin: got invalid ranges for 
selector set of fully-specified flow [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI65BADPARAM: PcpManSetInitMode: got invalid flags [hex] 
for setting fast policy mode 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI66NOTREADY: PcpManUpdateFlow: cannot update flow [dec] 
when SA is not active 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI67BADPARAM: PcpSpdCreateSMap: cannot create SMap [int] 
with Acl [int] when Acl state is [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI68BADPARAM: PcpAclAppend: got invalid flags [hex] at 
lineNo=[dec], aclId=[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI69BADPARAM: PcpManCreateCme: cannot create Cme [int] with 
spdId [int] out of range [0,[int]] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI7BADPARAM: PcpManSetFlowKeys: cannot set keys for flow 
[dec]: invalid ID 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI7OUTOFSEL: SpdSaTmInstallOut: cannot compute outbound 
SA's permit-SelSets from mixed SelSet list 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI70IDNOTINUSE: PcpManUpdateCme: cannot update 
non-existing Cme [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI71QUEUEFULL: PcpSpdUpdateCme: cannot update Cme [int]: 
queue is full 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI72QUEUEFULL: PcpSpdCreateSMap: cannot create SPD map with 
mapId [int]: queue is full 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI73BADPARAM: PcpSpdCreateSMap: cannot create SPD map with 
mapId [int] out of range [0,[int]] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI74IDINUSE: PcpSpdCreateSMap: cannot create SPD map with 
mapId [int] already in use 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI75TMFAILED: PcpSMapInstall: cannot insert SMap [int] with 
TcamMan 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI76BADPARAM: PcpSpdCreateSMap: cannot create SPD map [int] 
with invalid flags [hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI77BADPARAM: PcpManCreateSMap: cannot create SPD Map [int] 
using non-existent access list [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI78OUTOFSMAP: PcpSpdCreateSMap: cannot create SPD map 
[int]: out of memory 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI79BADPARAM: PcpQOpActSaBegin: cannot activate Sa for 
cmeId=[dec], entry=[dec] when Cme is not ready 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI80QUEUEFULL: PcpManDestroyFlowAsync: cannot delete 
flowId [dec]: operation queue is full 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI81IDNOTINUSE: PcpQOpDelSaBegin: cannot delete already 
deleted flow [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI82QUEUEFULL: PcpManRemoveCme: cannot remove Cme with 
cmeId [int]: queue is full 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI83TMFAILED: PcpSpdInitialize: cannot insert SPD [int] 
with TcamMan 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI84BADPARAM: PcpManCreateSMap: cannot create SPD map [int] 
with spdId [int] out of range [0,[int]] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI85OUTOFSMAP: PcpManCreateSpd: cannot create SPD [int]: 
out of memory 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI86IDINUSE: PcpManActivateFlowAsync: cannot activate 
already active flow [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI87BADPARAM: PcpManCreateFlow: cannot create Flow with 
id=[dec], max is [dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI88IDNOTINUSE: PcpManRemoveSMap: cannot remove 
non-existing SMap [int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-ACEI89OUTOFCME: PcpSpdCreateCme: cannot allocate new Cme for 
aclId=[int] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-3-SPI_NOT_AVAIL: SPI [hex] is not available 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

VPNSM-4

Error Message    %VPNSM-4-ACETCAMFULLINSMANSP: Full SA insertion for a manual SP. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACETCAMPKTNOSA: Packet event for a non-existing SA. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACETCAMPKTNOSP: Packet event for a non-existing SP. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUALLOC: IPC: Unable to allocate and send STATFLUSH. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUALLOC2: IPC: Unable to allocate IPC to set debug flag. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUALLOC3: IPC: Unable to allocate IPC to start 5840 test. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUCMMTU2: CFGMON: Failed to set MTU. Invalid data [dec], 
ifvlan [hex].

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUCMRESP: XcpuCfgMonReqCallback:Can't respond to host. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUCMRESP3: XcpuCfgMonReqCallback:Global stats...Can't 
respond to host. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUCMRESP4: XcpuCfgMonReqCallback: PerFlow 
Stats....Can't respond to host. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ACEXCPUCMRESP5: XcpuCfgMonReqCallback: PerFlow 
Stats....Can't respond to host. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-DUMPMEM: [hex]: [hex] [hex] [hex] [hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-EDSDEBUG: SingleBufErr:([hex]) 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-FIPSCHECK2: FIPS RCVD Multi-buffer Packet. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-FIPSCHECK3: FIPS Failed Packet Comparison. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-FIPSCHECK4: FIPS Test Completed Successfully. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUFRAG1: PktReasmSetAction failed. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP2: SaCheckSelectors: Illegal pkt, no valid SA 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP3: Illegal pkt dst:[dec].[dec].[dec].[dec] proto:[dec] 
spi:[hex], no match on SA SPI [hex]. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP4: Illegal pkt dst:[dec].[dec].[dec].[dec] proto:[dec] 
spi:[hex], no match on SA dst[dec].[dec].[dec].[dec] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP8: Illegal clear pkt src:[dec].[dec].[dec].[dec] 
dst:[dec].[dec].[dec].[dec] proto:[dec]. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP9: Packet src:[dec].[dec].[dec].[dec] 
dst:[dec].[dec].[dec].[dec] seq num:[hex] failed replay check last seq num:[hex] 
for SA:[hex]. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP10: Packet src:[dec].[dec].[dec].[dec] 
dst:[dec].[dec].[dec].[dec] proto ESP, but not SA proto! 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP11: Packet src:[dec].[dec].[dec].[dec] 
dst:[dec].[dec].[dec].[dec] proto AH, but not SA proto! 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP12: IPPE says IPSec, not pkt 
src:[dec].[dec].[dec].[dec] dst:[dec].[dec].[dec].[dec] proto:[dec]! 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP13: Policy check failed for pkt 
src:[dec].[dec].[dec].[dec] dst:[dec].[dec].[dec].[dec] proto:[dec] SA 
index:[hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP14: Pkt src:[dec].[dec].[dec].[dec] 
dst:[dec].[dec].[dec].[dec] proto:[dec] match deny; SA index [hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP15: SecInfo [hex] doesn't match with SA [hex] SA 
index:[hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUPP16: Inner proto [dec] must be IPSec but is not 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUSYSIPADDRADD: PktProcAddSysIpAddr: Unable to add local IP 
Addr [hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ICPUSYSIPADDRDEL: PktProcAddSysIpAddr: Unable to delete local 
IP Addr [hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-ISAUNCA7: PktProcAtnModSas: Mismatch valid flag unca:invalid 
index:[hex] 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-RECOVERYDONE: CP Lockup Recovery - Done 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-RECOVERYFRAG: Ipfrag: Unable to transmit. CP Lockup Occured. 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-RECOVERYSTART: CP Lockup Recovery - Start(OCPU) 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-4-XCPURECOVERY: Error Disabling CP 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

VPNSM-6

Error Message    %VPNSM-6-ACEPKAHWCRNGT: PKA: HW RNG has duplicate data, discarding 

Explanation    An error has been reported by the firmware.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSM-6-ACEPKARNGDUP: PKA: A pseudo-random number was generated twice 
in succession. [hex][hex]; 0Unrecognized format `x%p' 0Unrecognized format `x%p' 
idx:[hex] 

Explanation    An error has been reported by the firmware

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

VPNSMIOS Messages

This section contains VPNSM crypto connection (VPNSMIOS) messages.

VPNSMIOS-3

Error Message    %VPNSMIOS-3-ILLEGALINTERFACE: Traffic matching crypto maps on [chars] 
will go through unencrypted. Please reconfigure crypto maps as required by VPN 
service module. 

Explanation    An attempt was made to apply an encryption (crypto) map set to an interface that is not a VLAN interface. When this IPsec VPN accelerator is being used, crypto map sets can only be applied to a VLAN interface that has a proper encryption (crypto) connection to a physical port. The interface has been disabled. For more information about crypto guidelines, consult the system configuration manuals.

Recommended Action    Remove the crypto map set from the virtual interface. For more details, consult the configuration guidelines.

Error Message    %VPNSMIOS-3-MACEDONNOCCONB2BERR: [chars]no crypto connect is 
disallowed 

Explanation    The system cannot remove the cryptographic connection when a module-to-module partner is still active.

Recommended Action    Remove the module-to-module configuration before removing the cryptographic connection.

Error Message    %VPNSMIOS-3-MACEDONTUNNELADDCBERR: [chars]: tunnel addcb failed: 
reason[[chars]] tvlan[[dec]] slot[[dec]] 

Explanation    An error response was received while an attempt was made to seize the tunnel.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELADDERR: [chars]: tunnel add failed: 
reason[[chars]] ifvlan[[dec]] tvlan[[dec]] slot[[dec]] src[[IP_address]] 
dst[[IP_address]] 

Explanation    An error response was received while an attempt was made to seize the tunnel.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELCREATEPOLOQERR: Failed to create 
PoloReplicateCfg Q 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELCREATEPROCERR: Failed to create Ace Tunnel 
Task 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELCREATEQERR: Failed to create watched Q 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELDELETEIFVLANNOTFOUNDERR: [chars]: no tm 
found while attempting to delete from ifvlan[[dec]] 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELDELETETMNOTFOUNDERR: [chars]: no tm found 
while attempting to delete 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELNOEVENTMSGHANDLERERR: msgtype[[chars]]: No 
event msg handler found. 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELNOIDBERR: No tunnel idb 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELNOTMMSGHANDLERERR: msgtype[[chars]]: No tm 
msg handler found. 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELREMOVECBERR: [chars]: tunnel removecb 
failed: reason[[chars]] tvlan[[dec]] slot[[dec]] 

Explanation    An error response was received while the tunnel was being released.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELREMOVEERR: [chars]: tunnel remove failed: 
reason[[chars]] ifvlan[[dec]] tvlan[[dec]] slot[[dec]] src[[IP_address]] 
dst[[IP_address]] id[[dec]] 

Explanation    An error response was received while the tunnel was being released.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELVACLERR: vlan[[dec]]: failed to set vacl: 
action[[dec]] reason[[dec]] 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELVLANERR: [chars]: allocated idb has invalid 
vlan id 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-MACEDONTUNNELVLANIDBERR: [chars]: unable to allocate idb 

Explanation    An internal error has occurred.

Recommended Action    Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

Error Message    %VPNSMIOS-3-SLOTMISMATCH: [chars] has mismatch crypto engine binding. 
Egress interface is binded to crypto engine [int]/[int] but tunnel protection is 
binded to [int]/[int]. This tunnel is now shutdown. 

Explanation    In order to use VPN-SM for tunnel protection, the user must enter the crypto engine slot slot command on both the egress interface VLAN and the tunnel interface. The slot on both must match. When this requirement is not met, this message is displayed. The tunnel is now in a shutdown state.

Recommended Action    Modify either one or both crypto engine slot values so that they match.

Error Message    %VPNSMIOS-4-VPNSMILLEGALQOS0: VPNSM Slot: [dec] can only support [dec] 
cos maps in high priority queue, CoS configuration ignored, reset cos map by 
issuing no priority queue cos-map 1 command 

Explanation    An illegal configuration has been detected.

Recommended Action    Reset the CoS map by entering the no priority-queue cos-map 1 command. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://tools.cisco.com/Support/BugToolKit/. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the information you have gathered. Attach the following information to your case in nonzipped, plain-text (.txt) format: the output of the show logging and show tech-support commands and your pertinent troubleshooting logs.

VSEC Messages

This section contains VACL logging (VSEC) messages.

VSEC-4

Error Message    %VSEC-4-VLANACCESSLOGRF: FAILED to set VACL-LOG rate limiter. Is 
strongly suggested to rate limit when using this feature

Explanation    The configuration for the VACL logging rate limiter has failed.

Recommended Action    Determine the rate limiter usage, free some resources if possible, and then try to set the rate limiter again.

WCCP Messages

This section contains Web Cache Communication Protocol (WCCP) messages.

WCCP-3

Error Message    %WCCP-3-BADACE: Service [chars], invalid access-list entry (seq:[dec] 
reason:[chars]) 

Explanation    The access control list (ACL) associated with the specified WCCP service contains an incompatible entry. The hardware cannot process the resultant merged access list and will fall back to software-based NetFlow switching.

Recommended Action    Remove or change the incompatible entry in the ACL.

WiSM Messages

This section contains wireless service module (WiSM) messages.

WiSM-3

Error Message    %WiSM-3-PORTCHANNEL: Portchannel allocation failed for module [dec].

Explanation    The system is unable to allocate enough port channel groups for the WiSM card. [dec] is the module number.

Recommended Action    If this message recurs, copy the error message exactly as it appears on the console or in the system log. Research and attempt to resolve the error using the Output Interpreter https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl. Also perform a search of the Bug Toolkit http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet http://tools.cisco.com/ServiceRequestTool/create, or contact your Cisco technical support representative and provide the representative with the gathered information.