Configure Circuits

The OTN circuits allow you to setup end to end circuits from the origin to a destination network element. The Optical Channel Trail circuits allow you to create circuits in a network where the NCS 4000 series node is connected to ONS 15454, ONS 15454 M2, or ONS 15454 M6 nodes. This chapter provides the CTC procedures to configure the circuits.

Understand OTN Circuits

An OTN circuit provides the ability to aggregate different types of traffic such as Ethernet, SONET or SDH, and packet over OTN at different data rates such as 1.25, 2.5, 10, 40, or 100 GBit per second. This aggregated traffic is transported by network elements that acts as OTN cross connections.

ODUk controllers can be cross connected with controllers of the same rate in an OTN circuit by a fabric card. The following network applications are associated with OTN network elements:
  • End-to-end circuits from any rate or any payload client service

  • End-to-end circuit from a client service versus the OTN (OTUk) network

  • Aggregation of OTN traffic (OTUk)

Understand Circuit Diversity

This feature enables the user to create a circuit that is diverse from an existing circuit in the network. This is to increase survivability and availability in case of link failures.

During the computation of a diverse circuit, the GMPLS algorithm attempts to find a shared resource link group (SRLG) diverse path. If the path is not available, node and link diversity is used to compute the new path. Enabling circuit diversity on an existing circuit causes re-signaling of the circuit.

The following restrictions are applicable to ODU TUNNEL circuits:
  • The diverse circuit must have the same head node.

  • Supported only for 1+0 circuits.

  • If a diverse path is not found, the circuit is not created.

This feature is supported on the NCS4K-4H-OPW-QC2 card.

Understand OSPF

Open Shortest Path First (OSPF) is a routing protocol designed to run an autonomous system. It maintains an identical database describing the topology of an autonomous system. From the identical database, a shortest path-tree calculates the routing table. OSPF-TE allows controlling the data packet's path.

OSPF provides following features:

  • Routing of area.

  • Routing of protection.

  • Minimizing the routing protocol traffic.

Understand MPLS TE

MPLS TE learns the topology and resources available in a network and then maps traffic flows to respective paths based on resource requirements and network resources, for example, bandwidth. MPLS TE builds a unidirectional tunnel from a source to a destination in the form of a label switched path (LSP), which is then used to forward traffic. Tunnel head end or tunnel source is the point where the tunnel begins, the tunnel tail end or tunnel destination is the node where the tunnel ends .

Understand Tandem Connection Monitoring

Tandem Connection Monitoring (TCM) layer is used for protection applications, for example, APS. The path layer can be used for protection, however, it can be influenced by errors that occur outside a given operators network and cause undesired protection switch events to occur within their network. Since TCM can isolate a service to a given domain, it can be used to trigger protection applications and avoid such issues.

Six levels of TCM, each with various modes of operation, are provided to allow for simultaneous use for different monitoring applications along any each and every individual ODU trail.  These applications include: segment protection, administrative domain monitoring, service monitoring, fault localization, verification of delivered quality of service, delay/latency measurements and adjacency discovery. 

Understand Automatic Protection Switching

Automatic Protection Switching (APS) is a protection mechanism for OTN networks that enables OTN connections to switch to another circuit when a circuit failure occurs. A protect circuit serves as the backup circuit for the working circuit. When the working circuit fails, the protect circuit quickly assumes its traffic load.

In a linear protection architecture, protection switching occurs at the two distinct endpoints of a protected circuit. For a given direction of transmission, the head-end or the tail-end of the protected signal performs a bridge function, and places a copy of a normal traffic signal onto a protection entity when required. The tail-end or the head-end performs a selector function, where it is capable of selecting a normal traffic signal either from its usual working entity, or from a protection entity.

The widely used protection mechanism is the 1+1 architecture. Here, a single normal traffic signal is protected by a single protection entity. The bridge at the head-end is permanent. Switching occurs entirely at the tail-end.

In the case of bidirectional transmission, it is possible to choose either unidirectional or bidirectional switching. With unidirectional switching, the selectors at each end are fully independent. With bidirectional switching, an attempt is made to coordinate the two ends so that both have the same bridge and selector settings, even for a unidirectional failure. Bidirectional switching always requires an APS and/or protection communication channel (PCC) to coordinate the two endpoints. Unidirectional switching can protect two unidirectional failures in opposite directions on different entities.

Hierarchy in APS

There are different levels of priority that can be set for the path to switch from a working circuit to the protect circuit (or vice-versa). The hierarchy levels are (listed priority-wise, with lockout having the highest priority):

  • Lockout - the path continues to be in the working circuit, even if a failure is detected in the working circuit, switch to the protect circuit is not permitted. If the path is currently using the protect circuit, then it automatically switches back to the working circuit.

  • Forced switch - forces a switch from the protect circuit to the working circuit (even when the protect circuit is down, this scenario can happen during a maintenance activity).

  • Manual switch - manually switches from the working circuit to the protect circuit or from the protect circuit to the working circuit.

  • Exercise - enables the APS protocol.

    m

Understand Subnetwork Connection

Subnetwork Connection Protection (SNCP) configurations provide duplicate fiber paths for a circuit. Working traffic flows in one direction and protection traffic flows in the opposite direction. If a problem occurs with the working traffic path, the receiving node switches to the path coming from the opposite direction. The node at the end of the path and the intermediate nodes in the path select the best traffic signal. The virtual container is not terminated at the intermediate node, instead, it compares the quality of the signal on the two incoming ports and selects the better signal.

SNC can be classified into three types:
  • SNC/I (inherent) - Protection switching is triggered by defects detected at the ODUk link connection.

  • SNC/N (non-intrusive) - Protection switching is triggered by a non-intrusive monitor of the ODUkP trail.

  • SNC/S (sublayer) - Protection switching is triggered by defects detected at the ODUkT sublayer trail (TCM). An ODUkT sublayer trail is established for each working and protection entity.

Understand 1+R Protection

1+R protection mechanism is SNC-based. In case of work path failure, the circuit uses the restore path. Here, the protect path is not defined by the user (as in case of other protection mechanisms). The restore path is defined by the GMPLS protocol. To enable GMPLS, see Enabling GMPLS Using CTC

1+1+R

In 1+1+R protection mechanism, a circuit is protected by two redundant paths, one is the protect path and the other one is the restore path. When a failure occurs on the working and the protect paths, then the restore path takes over. Wait to Restore (WTR) timers are available on both the working and protect paths. Restoration path signalling is triggered as soon as a defect is detected on either of the paths (working or protect). So, when the working path fails, the traffic shifts to the protect path. In this period of time, the restore path is ready to take over as soon as the protect path fails too; the switchover time is less than 50ms.

These are the limitations for 1+1+R protection mechanism:

  • Unidirectional protection type is not supported.

  • Manual switch to restore is not supported.

Understand ISSU Upgrade

In-Service Software Upgrade (ISSU) is a technique that updates the software packages on a network element without affecting the traffic. By using ISSU, you can deploy new Cisco IOS XR Software images that supports new software features and services. The Cisco IOS XR ISSU capability extends Cisco high availability innovations for minimizing planned downtime for service provider networks.

Understand GCC Management

General Communication Channel (GCC) is an in-band side channel that carries transmission management and signaling information within optical transport network elements.

There are two types of GCC links:

  • GCC0 - two bytes within OTUk overhead.
  • GCC1 - two bytes within ODUk overhead.

Understand GMPLS

Generalized Multi-Protocol Label Switching (GMPLS) extends the packet based MPLS protocol to allow creation and maintenance of tunnels across the networks that consist of non-packet switching devices. GMPLS tunnels can traverse the Time-Division Multiplex (TDM) interface and switching types.

The following protocols are associated with GMPLS:

  • OSPF

  • OSPF-TE

  • RSVP-TE

  • MPLS-TE

  • LMP

Understand Explicit Path

Explicit path refers to a user defined path taken by a circuit. GMPLS dynamically determines the path to be taken by a circuit but user can override this path by configuring an explicit path.

Interoperability between NCS 4000 and MSTP Nodes using NCS4K-4H-OPW-QC2 Card

Interoperability between NCS 4000 and MSTP nodes is achieved by creating a Link Management Protocol (LMP) numbered or unnumbered UNI link between NCS4K-4H-OPW-QC2 interface on the NCS 4000 node and the optical channel Add/Drop interface on the MSTP nodes.

To create OTN circuits between the NCS 4000 nodes via the MSTP network, a GMPLS OCH Trail circuit must be created between the two NCS 4000 nodes that are connected to MSTP nodes. The traffic transmitted by the OCH Trail circuit is used as a OTU4 or OTUC2 link by the OTN layer.

To configure interoperability, complete the Configure Interoperability Between NCS 4000 and MSTP Nodes procedure.

Provision Management IP Address

Purpose

This procedure provisions the management IP address for the node.

Tools/Equipment

None

Prerequisite Procedures

" Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite

Security Level

Provisioning or higher

Procedure


Step 1

In the Node View, click the Provisioning > Network > General tabs.

Active RP—Displays the details of the active route processor.

Step 2

In the Mgmt IP area, complete the following information:

  • Virtual IP Address - Enter an IP address drawn from the management IP address pool that supersedes the IP addresses of RP0 and RP1.

  • Mask - Enter the subnet mask of the IP address.

Step 3

In the RP0-EMS IP and RP1-EMS IP areas, complete the following information:

  • IPv4—Enter the IPv4 address assigned to RP0/RP1 EMS.
  • IPv4 Mask—Enter the IPv4 subnet mask.
  • Service State—Select the state from the drop-down menu. The available options are - IS (in-service) and OOS (out-of-service).

Step 4

In the RP0-Craft IP and RP1-Craft IP areas, complete the following information:

  • IPv4—Enter the IPv4 address assigned to RP0/RP1 Craft panel.
  • IPv4 Mask—Enter the IPv4 subnet mask.
  • Service State—Select the state from the drop-down menu. The available options are - IS (in-service) and OOS (out-of-service).

Step 5

In the RP0-Mgmt IP and RP1-Mgmt IP area, complete the following information:

  • IPv4—Enter an IP address drawn from the management IP address pool.
  • IPv4 Mask—Enter the subnet mask for the IP address.
  • Mac Address—Displays the MAC address of RP0/RP1.
  • IPv6—Enter an IP address drawn from the management IP address pool.
  • IPv6 Prefix Length—Enter the prefix length for the IP address.
  • Service State—Select the state from the drop-down menu. The available options are - IS (in-service) and OOS (out-of-service).

Step 6

In the Gateway area, enter IPv4 or IPv6 address and enter the prefix length if you use IPv6 address. The prefix length must be between 0 and128.

Step 7

Click Apply.

Stop. You have completed this procedure.


Configure the Loopback on an Interface Using CTC

Purpose

This procedure provides instructions to configure the loopback on an interface using CTC. It also helps in management logging and authentication of a user on an interface for NCS4K-20T-O-S, NCS4K-2H-O-K,NCS4K-24LR-O-S, NCS4K-2H10T-OP-KS or NCS4K-4H-OPW-QC2 Line cards.

Tools/Equipment

None

Prerequisite Procedures

Login to CTC in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Configure an OTN Controller Using CTC

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Node View, double-click the line card.

Step 2

Click the Maintenance > Loopback tab.

Step 3

To configure loopback on OTN controllers, perform the following steps in the screen that appears:

  1. Click the Controller column and select a name of the controller.

  2. Click the Admin State Column.

  3. Choose Service State for the controller. For more information, see Administrative and Service States.

  4. From the Loopback Type drop-down list, choose Internal, Line or None.

  5. Click Apply.

  6. Click Refresh to refresh all the controllers.

Stop. You have completed this procedure.


Enabling GMPLS Using CTC

Purpose

This procedure helps in enabling the Traffic Engineering (TE) links.

Tools/Equipment None
Prerequisite Procedures None
Required/As Needed Required.
Onsite/Remote Onsite or remote
Security Level Provisioning or higher

Procedure


Step 1

To configure a GCC on a controller, complete Configuring GCC Using CTC.

Step 2

To configure OSPF on an interface, complete Add OSPF on an Interface Using CTC.

Step 3

To configure OSPF-TE, complete Configure OSPF-TE on an Interface Using CTC.

Step 4

To configure MPLS-TE, complete Configure an MPLS-TE Instance Using CTC.

Step 5

To configure RSVP-TE, complete Configure a RSVP-TE Instance Using CTC.

Stop. You have completed this procedure.


Configuring GCC Using CTC

Purpose

This procedure enables you to configure General Communication Channel (GCC) on a controller for NCS4K-20T-O-S, NCS4K-2H-O-K, NCS4K-24LR-O-S, NCS4K-2H10T-OP-KS, and NCS4K-4H-OPW-QC2 line cards.

Tools/Equipment None
Prerequisite Procedures "Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Configure an OTN Controller Using CTC

Required/As Needed Required.
Onsite/Remote Onsite or remote
Security Level Provisioning or higher

Procedure


Step 1

In the Node View, double-click the line card.

Step 2

Click the Provisioning > Controllers > OTU or ODU tabs.

Step 3

To enable GCC on the controller, perform one of the following steps:

  1. For OTU controller, check the GCC0 check box.

  2. For ODU controller, check the GCC1 check box.

Step 4

Click Apply.

Step 5

In the Node View, click the Provisioning > Comm Channels tabs.

Step 6

To assign IP address to the GCC, add IP address in the IP address field and network mask in the NetMask field.

Note

 

To assign loop back IP address to the GCC, select a Loopback from the drop down list.

Same loop back IP address can be assigned to multiple GCC's .

Step 7

Click Apply.

Step 8

Return to your originating procedure.


Add OSPF on an Interface Using CTC

Purpose

This procedure enables you to configure the OSPF on an interface using CTC. Adding OSPF allows to setup a link between two different routers and maintain the connectivity interface.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Configure the Loopback on an Interface Using CTC

Required/As Needed

Required

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Node View, click the Provisioning > Network > OSPF tabs.

Step 2

Perform following steps to create an OSPF instance:

  1. From OSPF Instance Name drop down list, select OTN.

  2. From Router Id drop down list, select the router id.

    Note

     

    Recommended configuration is Virtual IP.

  3. Click Apply.

Step 3

Select the NSR check-box to enable redundant route processors to maintain its Open Shortest Path First (OSPF) state and adjacencies across planned and unplanned IP switchovers.

NSR stands for Non -Stop Routing.

Step 4

Select the NSF (IETF) check-box to continue forwarding IP packets following a supervisor engine switchover.

NSF stands for Non-Stop Forwarding.

Step 5

Perform following steps to add GCC interface to OSPF:

  1. In OSPF Interfaces section, click Add. The Create OSPF Entry dialog box appears.

  2. In the Interface drop down list, select the interface.

    Note

     

    Add Loopback interface and GCC interface both, if loopback IP is assigned to GCC .

    Repeat step3 to add multiple interfaces.

  3. In the Area ID field, a default value of 0 is populated.(non-editable).

  4. (Optional) In the Cost field, enter the cost.

  5. (Optional) Check the Passive check box to ensure the updates are not sent beyond an OSPF interface.

  6. Click OK.

Step 6

Click Apply.

Step 7

Return to your originating procedure.


Configure OSPF-TE on an Interface Using CTC

Purpose

This procedure enables you to configure the OSPF-TE using CTC. OSPF-TE allows controlling the path of data packets and advertise the capabilities of TE links to remote nodes.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Configure an OTN Controller Using CTC

Add OSPF on an Interface Using CTC

Required/As Needed

Required

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Node View, click the Provisioning > Network > OSPF-TE tabs.

Step 2

From the OSPF-TE Router Id drop down list, select router id.

Note

 

Recommended configuration is Virtual IP.

Step 3

To configure the OSPF-TE on an Interface, complete the following:

  1. In the Area ID field, a default value of 0 is populated (non-editable).

  2. Check the Autoconfig check box to enable all the interfaces of the OSPF-TE.

  3. Click Apply.

Step 4

Return to your originating procedure.


Configure an MPLS-TE Instance Using CTC

Purpose

This enables you to configure an MPLS-TE instance that helps to route network traffic using CTC. Traffic engineering enables to reduce the cost of the network and offer the best service to the users.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Configure an OTN Controller Using CTC

Required/As Needed

Required

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Node View, click the Provisioning > Network > MPLS-TE tabs.

Step 2

Click Create. The Create MPLS Topology Instance Entry dialog box appears.

Step 3

Click OK to create a MPLS-TE instance.

Step 4

In the Controllers section expand the row for the line card on which you want to configure MPLS-TE and perform the following steps to update the default values of the parameters:

  1. To enable TE link, set Enable field as true.

  2. From the TTI mode drop down list, select the TTI mode. Available options are PM, SM, TCM1,TCM2, TCM3, TCM4, TCM5, and TCM6.

  3. (Optional) Set the Admin Weight field with value ranging from 0 to 65535.

Step 5

Click Apply.

Step 6

Return to your originating procedure.


Configure a RSVP-TE Instance Using CTC

Purpose

This procedure enables you to configure a RSVP-TE instance.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As Needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Node View, click the Provisioning > Network > RSVP-TE tabs.

Step 2

In the Interface List area, for an Interface Name, select the RSVP State from the drop-down menu. The available options are - Enable and Disable.

Step 3

In the Card section, expand the row for required LC to view the list of configured controllers.

Step 4

Select a controller and perform the following sub steps:

  1. Set the Enable field of the controller to true.

  2. (Optional) Input value for Refresh Optical Interval. Valid range is 180 to 86400 seconds.

  3. (Optional) Input value for Missed Messages. Valid range is 1 to 110000.

Step 5

Click Apply to save the changes.

Stop. You have completed this procedure.


Configure OTN Circuits Using CTC

Purpose

This procedure configures an OTN Circuit Using CTC.

Tools/Equipment None
Prerequisite Procedures

Configure an OTN Controller Using CTC

Enabling GMPLS Using CTC

Required/As Needed As needed
Onsite/Remote Onsite or remote
Security Level Provisioning or higher

Procedure


Step 1

Perform any of the following procedures as needed to create, load, and store the path protection profile:

Step 2

Perform any of the following procedures as needed to configure an OTN circuit:

Step 3

Perform any of the following procedures as needed to create, load, and store the explicit path:

Stop. You have completed this procedure.


Add a Path Protection Profile Using CTC

Purpose

This procedure provides instructions to add a path protection profile using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Path Protection Profiles.

Step 2

Click Add. Perform the following steps in the editable row:

  1. In the Name column, enter the Path Protection Profile name.

  2. In the Wait to Restore (WTR) field (in seconds), enter the duration of time (in seconds).

    Note

     

    It defines the time the system must wait to restore a circuit. To edit the WTR value, Revertive should be set to Yes. The valid range is 0 or from 300 to 720 seconds. WTR value is in multiple of 60. Default value for WTR is 300.

    WTR is not supported on a non-revertive circuit.

  3. From the Sub Network Connection Mode drop-down list, choose any from the following: SNC_N (default), SNC_I and SNC_S.

    Note

     

    A new entry will be created with Sub Network Connection Mode value as SNC_N and TCM-ID value as NONE.

  4. In the Hold Off (milli sec) field, enter the duration of time (in seconds) .

    Note

     

    It defines the time the system waits before switching to the alternate path. The valid range is 0 or from 100 to 10000 seconds. Hold off value is in multiple of 100. Default value is 0.

  5. From the Protection Type drop-down list, choose a protection type from the available options 1+1-BIDIR-APS (Default) or 1+1-UNIDIR-APS or 1+1-UNIDIR-NO-APS.

  6. From the Revertive drop-down list, choose Yes or No. Default is No.

  7. From the TCM-ID drop-down list, choose None.

Step 3

From the Sub Network Connection mode drop-down list, choose SNC_S.

Step 4

From the TCM drop-down list, choose an option.

Note

 
By default, TCM-4 is selected once you select SNC-S as Sub Network Connection mode. You can change the TCM-ID column value from TCM4 to TCM1-TCM6 for SNC-S.

Note

 
For SNC-I and SNC-N, You are not allowed to change the TCM-ID value. It should be set to None.

Step 5

Click Store to store the profile for the particular node.

Step 6

The Store Profile(s) window is displayed.

Step 7

By default, the To Node(s) radio button is selected. Select the required nodes from the Node Names area, to set the profile. Click Select All to set the profile for all the selected nodes. Click Select None to undo your earlier selection.

Step 8

Click OK.

Step 9

Select the To File radio button, and click Browse to save the profile in your local machine.

Step 10

Return to your originating procedure.


Provision Loopback Interface

Purpose

This procedure provisions the loopback interface on the node.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite

Security Level

Provisioning or higher

Procedure


Step 1

In the node view, click the Provisioning > Network > Loopback IF tabs.

Step 2

If you want to create a loopback interface, complete the following:

  • Click Create. The Create Loopback Interface dialog box appears.
  • Enter the Interface ID, IP address, and network mask in the respective fields and click OK.

Step 3

If you want to edit a loopback interface, complete the following:

  • Click Edit. The Edit Loopback Interface dialog box appears.
  • Modify the values of the IP Address and network mask as required and click OK.

Step 4

Return to your originating procedure.


Load a Path Protection Profile Using CTC

Purpose

This procedure provides instructions to load a path protection profile using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning, higher or retriever

Procedure


Step 1

In the Network View, click the OTN > Path Protection Profiles tab.

Step 2

Click Load. Perform one of the following in the Load Profile (s) dialog box that appears.

  1. From the From Node (s) pane, select a name of the node to load the path protection profiles.

  2. Click OK.

  3. In the From File field enter the path of the file or browse to the file, to load the path protection profile.

    Note

     

    You can load the profiles from a file that has OTN extension.

  4. Click OK.

Step 3

Return to your originating procedure.


Store a Path Protection Profile Using CTC

Purpose

Storing a Path Protection Profile allows to store cross connection on the same chassis. This procedure provides instructions to store a path protection profile using CTC.

Tools/Equipment

None

Prerequisite Procedures

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Path Protection Profilestab.

Step 2

Click Store. Perform one of the following in the Store Profile (s) dialog box that appears.

  1. From the To Node (s) pane, select a name of the node to store the path protection profiles.

  2. Click Select All to select all the node names.

  3. Click Select None to deselect the selected node names.

  4. To store the profile to a file, select the To File option and clickBrowse to select the required file, to store the path protection profile.

Step 3

Click OK

Step 4

Return to your originating procedure.


Configure an Open End OTN Circuit Using CTC

Purpose

OTN circuit allows the end user to setup end to end circuits from an origin to a destination Network Element. This procedure provides instructions to configure an open end OTN circuit using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Circuits tab.

Step 2

Click Create. The Circuit Creation wizard appears.

Step 3

In the Circuit Type screen of the wizard, choose a circuit type ODU UNI from the list.

Step 4

Enter a value between 1 to 80 for the number of circuits to be created.

Step 5

Click Next.

Step 6

In the Circuit Attributes screen of the wizard:

  1. From the Source Node drop-down list, choose a source node for the circuit.

  2. From the Destination Node drop-down list, choose a destination node for the circuit.

  3. In the Namefield, enter the circuit name.

    Note

     

    The length must not exceed 64 characters.

  4. From the Bandwidth drop-down list, choose a bandwidth.

  5. Click the Bandwidth Configuration hyperlink.

    Note

     

    This hyperlink is enabled when you select the bandwidth type as ODUFLEX.

    Perform the following steps in the Bandwidth Configuration dialog box that appears.
    • In the Bit Rate field enter the bit rate. The bit rate per time slot is 1249177. Example for ODU2 we have 8 timeslots, so bit rate will be 1249177 * 8 = 9993416.

    • From the Framing Type drop-down list, choose CBR or GFP-F-Fixed (for 10 Gigabit Ethernet).

    • Click OK.

  6. From the Protection Type drop-down list, choose an option 1+0, 1+1 or 1+R.

  7. Click the Path Option Configuration hyperlink. The Path Option Configuration screen appears.

    Note

     

    It is optional to configure the working path option. When you configure the path option using Path Option Configuration hyperlink, the selection made in the Protection Type drop-down list will be overridden.

    Click Add. Perform the following steps in the Create/ Edit Path Option dialog box:

    • In the Index field enter a unique index. The valid range is from 1 to 1000.

    • In the Path Option drop-down list, choose Working or Protect.

    • From the Path Option Type drop-down list, choose Dynamic or Explicit.

    • From the Path Name drop-down list, choose an explicit path name.

      Note

       

      The Path Name field is disabled, if the path option type is dynamic.

    • From the Protected By drop-down list, choose a protected path option.

      Note

       

      The Protected By drop-down list is disabled if the Path Option is set to Protect.

    • From the Restored By drop-down list, select a restored path option. If any of the working or protected path fails, restored path replaces the failed path.

      Note

       

      The Restored By drop-down list is disabled if you have selected path option as Restored.

    • Click OK.

  8. From the Path Protection Profile drop-down list, choose an option. The option available is None. This drop-down list is disabled if protection type is selected as 1+0.

  9. Check the Record Route check box to record the route.

  10. (For ODU UNI) From the Service Type drop-down list, select an option. Service type values are populated based on the bandwidth selected.

  11. (For ODU UNI) Check the Open End check box to get the values populated in the Destination drop-down list.

  12. (For ODU UNI) From the Source drop-down list, choose a source port or controller. Source values are populated based on the service type or open end selected

  13. (For ODU UNI) From the Destination drop-down list, choose a destination port or controller. Destination values are populated based on the service type or open end selected..

  14. Click thePath Option Configuration hyperlink button.

    Perform the following steps in the Create/Edit dialog box that appears.

    • From the ODU Level drop-down list, choose an option. ODU Level values are populated based on the Destination. ODU level is one less than the Destination. If Destination is selected as ODU2, values in this drop-down list would be ODU1 and ODU0.

    • Select a time slot highlighted in green color above, press Ctrl key and select the next time slot.

    • Click Channelize to allocate the time slot to the lower order channelize controller. The lower order controller appears in the controller tree hierarchy.

    • Click OK.

  15. Click Finish to create the circuit.

Step 7

Return to your originating procedure.


Configure an OTN Circuit Using CTC

Purpose

This procedure configures an OTN circuit using CTC.

Tools/Equipment

None

Prerequisite Procedures

You can load the profiles from a file that has OTN extension.

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the network view, click the OTN > Circuits tab.

Step 2

Click Create. The Circuit Creation wizard appears.

Step 3

In the Circuit Type screen of the wizard, choose ODU TUNNEL as the circuit type.

Step 4

Click Next.

Step 5

In the Circuit Attributes screen of the wizard:

  1. From the Source Node drop-down list, choose a source node for the circuit.

  2. From the Destination Node drop-down list, choose a destination node for the circuit.

  3. Enter the circuit name. The length must not exceed 64 characters.

  4. Check the Diversity checkbox and choose the circuit from the drop-down list whose diverse circuit you want to create.

    Note

     

    This step is applicable only when diverse circuit is created.

    The drop down list will display <tunnel id>: <circuit name>

  5. From the Bandwidth drop-down list, choose a bandwidth.

  6. Click the Bandwidth Configuration hyperlink.

    Note

     

    This hyperlink is enabled when you select the bandwidth type as ODUFLEX.

    Perform the following steps in the Bandwidth Configuration dialog box that appears.

    • In the Bit Rate field enter the bit rate.

    • From the Framing Type drop-down list, choose CBR or GFP-F-Fixed (for 10 Gigabit Ethernet).

    • Click OK.

  7. From the Protection Type drop-down list, choose an option 1+0, 1+1, 1+R,1+1+R .

    Note

     

    Circuit diversity is supported only for 1+0 protection type.

  8. Click the Path Option Configuration hyperlink. The Path Option Configuration screen appears.

    Note

     

    This hyperlink is disabled when the Diversity checkbox is checked.

    Click Add. Perform the following steps in the Create Path Option dialog box:

    • In the Index field enter a unique index . The valid range is from 1 to 1000.

    • From the Path Option Type drop-down list, choose Dynamic or Explicit.

      Note

       

      For using the option Explicit, make sure that an explicit path is already defined. You can define an explicit path using procedure Add an Explicit Path Using CTC.

    • From the Path Name drop-down list, choose an explicit path name.

      Note

       

      The Path Name field is disabled, if the path option type is dynamic.

    • From the Affinity Attribute-Set Name drop-down list, choose an affinity profile.

    • From the Protected By drop-down list, choose a protected path option.

      Note

       

      The Protected By drop-down list is disabled for Restored or Protected path options.

    • From the Restored By drop-down list, select a restored path option. If any of the working or protected path fails, restored path replaces the failed path.

      Note

       

      The Restored By drop-down list is disabled if you have selected path option as Restored.

    • Click OK.

  9. From the Path Protection Profile drop-down list, choose an option. The default option is None.

    Note

     
    This drop-down list is disabled if protection type is selected as 1+0.
  10. Check the Record Route check box.

  11. Click Finish to create the circuit.

Step 6

Return to your originating procedure.


Discover a Circuit Using CTC

Purpose

This procedure provides instructions to discover a circuits from the list of OTN circuits using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Circuits tab.

Step 2

Click Query. Perform the following steps in the OTN Services Query screen that appears.

  1. From the Existing/New Query drop-down list, choose New or Existing.

  2. Enter the tunnel IDs if you have selected New Query.

    Note

     

    For Existing Query, Tunnel IDs and Query Group fields are populated automatically.

  3. Click Query Group. Perform the following steps in the User Query Group Chooser dialog box:

    • From the Group drop-down list, choose an option.

    • From the Available Nodes pane, choose a node.

    • Click >> to move the selected node from the Available Nodes to the Grouped Nodes pane.

    • Click Save to save this query group criteria. A dialog box appears, enter a name for the query group and click Save.

    • Click Apply All to select all the available nodes. These nodes appear in the field next to the Query Group button.

    • Click Apply Selected to select only the grouped nodes. These nodes appear in the field next to the Query Group button.

  4. Click Save to save the query criteria.

  5. Click Run Query to execute the query.

    Note

     

    The Run Query button gets enabled only when you enter a value in the Query Group field. The search result appears in the Query Matches pane.

  6. Enter a search criteria in the field adjacent to the Find Next button.

    Note

     

    This button gets enabled only when you have a value in the Query Matches pane.

  7. Click Find Next.

    Note

     

    The next value gets highlighted in the Query Matches pane based on the search criteria.

  8. From the Query Matches pane, choose a circuit.

  9. Click >> to move the selected circuit from the Query Matches pane to the Selected Services to Discover pane.

  10. Click Discover All to display all the circuits of the Query Matches pane on the Circuits tab.

  11. Click Discover Selected to display all the selected circuit of the Selected Services to Discover pane on the Circuits tab.

Step 3

Return to your originating procedure.


Edit General Parameters of a Circuit Using CTC

Purpose

This procedure provides instructions to edit general parameters of an OTN circuit using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Circuits tabs.

Step 2

Select a circuit and click Edit.

Step 3

Click the General tab. Perform the following steps in the Edit Circuit screen that appears:

  1. Modify the parameters such as Name, Bandwidth, Path Protection Profile, Bandwidth Configuration, Diversity and Source and Destination client interfaces as needed.

    Note

     

    Details of source and destination client interfaces are editable only when you update UNI circuits.

    Note

     

    The Path Option Configuration hyperlink is disabled when the Diversity checkbox is checked or when diverse circuit of the selected circuit exists.

  2. Click Apply to save the changes.

    Note

     

    CTC hangs for a minute when multiple edit circuit windows are opened with multiple pluggable OIR.

Step 4

Return to your originating procedure.


Edit ODU Configuration of a Circuit Using CTC

Purpose

This procedure helps to edit the ODU configuration of a circuit.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Discover a Circuit Using CTC

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Circuits tab.

Step 2

Select a circuit from the list.

Step 3

Click Edit.

For the procedure to view TCM parameters, see View TCM PM Parameters Using CTC

Step 4

Click ODU Configuration tab.

Step 5

From the left pane, click the ODU Line Configuration tab. Perform the following steps in the Edit ODU Line Configuration screen that appears:

  1. Select a controller from the list.

  2. From the Admin State drop-down list, choose Automatic in Service, Maintenance or Normal.

    Note

     

    This field displays the current status of a controller.

  3. From the Loopback drop-down list, choose an option Internal, Line or None.

  4. From the GCC1 drop-down list, choose Enable or Disable.

  5. Click Apply.

Step 6

From the left pane, click the ODU TTI Configuration tab. Perform the following steps in the Edit ODU TTI Configuration screen that appears:

Note

 
TTI configuration is not supported on HO ODUs.
  1. From the Controller Name drop-down list, choose controllers for the Source and Destination pane respectively.

    Note

     

    The values that you enter in the Transmit area of the Source pane are displayed in the corresponding fields of the Expected area of the Destination pane. Similarly, the values that you enter in the Expected area of the Source pane are displayed in the corresponding fields of the Transmit area of the Destination pane. The values of the Received area of the Source and Destination pane must be the same.

  2. In the Transmit area, click ASCII or Hex (1 byte) to specify the data type for the operator string.

  3. Click ASCII Mode. The operator string is converted to ASCII data type.

  4. Enter a new operator string. This string replaces the operator specific string when you click Apply.

  5. Repeat steps (b) through (d) to select a data type in the Expected area of the Source pane.

  6. Check the Auto-Refresh check box to refresh the received operator specific value automatically in every 5 seconds.

  7. Click Apply.

Step 7

From the left pane, click the TCM Line Configuration tab. Perform the following steps in the Edit TCM Line Configuration screen that appears:

  1. From the Controller Name drop-down list, choose a node.

  2. From the TCM Mode drop-down list, choose a mode.

    The available options are:
    • Transparent - TCM data is passed through without any change , fault management and performance monitoring parameters are not enabled.

    • Operational - fault management (the LTC-CA alarm can be enabled) and performance monitoring parameters can be enabled.

    • NIM (Non-Intrusive Monitoring) - Performance monitoring parameters are enabled but are read-only. The LTC-CA alarm cannot be enabled.

  3. Check the Enable PM check box to enable performance monitoring. This check box can be selected when the TCM Mode is either Operational or NIM.

  4. Select the LTC-CA (Loss of Tandem Connection-Consecutive Action) check box to enable this alarm. This check box can be selected only when the TCM Mode is Operational.

  5. Select the TIM-CA (Trace Identifier Mismatch-Consecutive Action) check box to enable this alarm. This check box can be selected only when the TCM Mode is Operational.

  6. Click Apply.

Step 8

From the left pane, click the TCM TTI Configuration tab. Perform the following steps in the Edit TCM TTI Configuration screen:

  1. From the Controller Name drop-down list, choose controller for the Source and Destination pane respectively.

    Note

     
    The values that you enter in the Transmit area of the Source pane are displayed in the corresponding fields of the Expected area of the Destination pane. Similarly, the values that you enter in the Expected area of the Source pane are displayed in the corresponding fields of the Transmit area of the Destination pane. The values of the Received area of the Source and Destination pane must be the same.
  2. From the TCM drop-down list, choose TCM on the Source and Destination pane respectively.

  3. In the Transmit area, click ASCII or Hex (1 byte) to specify the data type for the operator string.

  4. Click Hex Mode. The operator string is converted to hexadecimal data type.

  5. Enter a new operator string.

  6. Click Apply to replace the operator specific string.

  7. Repeat steps (c) through (e) to select a data type in the Expected area of the Source pane.

  8. Select the Auto-Refresh check box to refresh the received operator specific value automatically, every 5 seconds.

  9. Click Apply.

Step 9

From the left pane, click the PM Thresholds tab.

  1. Click the ODU Controller tab. Perform the following steps in the ODU controller screen that appears:

    Note

     
    Performance monitoring should be enabled for ODU controllers.
    • From the Controller Name drop-down list, choose a controller.

    • From the Layer Name drop-down list, choose an option Path or GFP. The PM threshold values get populated in the table appears on the screen.

    • Click either 15 Min or 1 Day interval to get the PM interval.

    • Click Refresh to get the updated PM threshold values in the table from the legacy node.

  2. Click the TCM tab. Perform the following steps in the TCM screen that appears:

    Note

     
    Permon should be enabled for TCM controllers.
    • From the Controller Name drop-down list, choose a controller. The PM threshold values get populated in the table appears on the screen.

    • Click either 15 Min or 1 Day interval to get the PM thresholds interval.

    • Click Refresh to get the updated TCM PM threshold values from the legacy node.

Step 10

Return to your originating procedure.


Add an Explicit Path Using CTC

Purpose

This procedure provides instructions to create an explicit path using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series.

Configure OTU for OTN Controller Using CTC

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Explicit Paths.

Step 2

Click Add. Perform the following steps in the Create Explicit Path screen:

  1. Enter a name of the explicit path.

    Note

     

    Strict path type is selected by default.

  2. Click Add. Perform the following steps in the Add Node dialog box. Alternately, select a node from the map, and click Add.

    • From the Node drop-down list, choosenode.

    • From the Interface drop-down list, choose an interface.

    • Click Apply.

  3. Click Apply to save the explicit path.

Step 3

Return to your originating procedure.


Store an Explicit Path Using CTC

Purpose

This procedure provides instructions to store an explicit path using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series.

Add an Explicit Path Using CTC

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the Explicit Paths > Explicit Paths tab.

Step 2

Click Store. Perform the following steps in the Store Explicit Path (s) dialog box:

  1. Check the check box adjacent to a node name.

  2. Click OK to store the explicit path.

Step 3

Return to your originating procedure.


Load an Explicit Path Using CTC

Purpose

This procedure provides instructions to load an explicit path using CTC.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series.

Store an Explicit Path Using CTC

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View, click the OTN > Explicit Path.

Step 2

Click Load. Perform the following steps in the Load Explicit Path (s) dialog box:

  1. Check the check box adjacent to a node name.

  2. Click OK to load the explicit path.

Step 3

Return to your originating procedure.


Create a Permanent Connection Using CTC

Purpose

This procedure enables you to create a permanent connection for NCS4K-20T-O-S, NCS4K-2H-O-K,NCS4K-24LR-O-S, NCS4K-2H10T-OP-KS, and NCS4K-4H-OPW-QC2 line cards, using CTC. Permanent connection allows to create a cross-connection.

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Node/Card View, double-click the line card.

Step 2

Click the Circuits > Permanent Connection tab.

Step 3

Click Create. Perform the following steps in the Create Permanent Connection dialog box that appears.

Note

 
User is allowed to create high order cross connection only. The high order being used should not be channelized. All the permanent connections (except high order connections) are read only.
  1. Enter the XConnect Name of the permanent connection. The connection ID value ranges from 1 to 32655.

  2. From the End Point 1 drop-down list, select the ingress point of the permanent connection.

  3. From the End Point 2 drop-down list, select the egress point of the permanent connection.

  4. Click OK.

Stop. You have completed this procedure.


Perform a Path Switch

Purpose

This procedure enables you to perform a path switch. The possible actions are:
  • Manual Switch Over

  • Force Switch Over

  • Lockout (available only on a working circuit)

Tools/Equipment

None

Prerequisite Procedures

"Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series

Required/As Needed

As needed

Onsite/Remote

Onsite or remote

Security Level

Provisioning or higher

Procedure


Step 1

In the Network View , click the OTN > Circuits tab.

Step 2

Select a circuit from the list. Ensure that the Type is 1+1.

Step 3

Click Edit.

Step 4

Click the Protection tab.

Step 5

The details of the selected circuit are displayed under the Source and Destination . The working circuit details are in green and the protect circuit details are in purple.

The same details are represented in a pictorial format, in the File section. To perform the switchovers, use this pictorial format.

Step 6

Right-click the port of the working circuit or the protect circuit.

The available options are:
  • Open Port - opens the card view of the line card.

  • Switch commands - displays the available switch over options.

Step 7

Select one of the options under Switch commands.

The available options are:
  • Manual Switchover - to switch from the working to the protect circuit or vice-versa

  • Force Switchover - to switch back to the working circuit

  • Exercise - to check the protocol in use

  • Lockout (available only for a working circuit)- the path continues to be on the working circuit (even if a failure is detected on the working circuit)

  • Clear Lockout (available only for a working circuit)- the path can now use the protect circuit

  • Clear - clears the manual switch option ( not available when the path is in the lockout mode)

Step 8

Return to the originating procedure.


Configuring OTN Circuits Using Node Configuration Wizard

Purpose

This procedure configures the OTN circuits using Node Configuration Wizard.

Tools/Equipment None
Prerequisite Procedures
    Required/As Needed As needed
    Onsite/Remote Onsite or remote
    Security Level Provisioning or higher

    Procedure


    Step 1

    In the Node View or Card View, right-click anywhere and choose the Node Configuration Wizard

    Step 2

    In the IP Configuration pane, if you want to provision the Virtual IP, Management IP, EMS IP, Craft IP, Gateway IP and the corresponding mask, complete the following :

    1. Enter the Virtual IP Address drawn from the management IP address pools that supersede the IP address of RP0 and RP1.

    2. Enter the Subnet Mask for the Virtual IP address previously entered.

    3. In the RP0-Mgmt IP and RP1-Mgmt IP areas, complete the following information:

      • IPv4—Enter a unique IPv4 address assigned to RP0/RP1. It displays blank if not configured.
      • IPv4 Mask—Enter the IPv4 subnet mask.
      • Rp0 or Rp1 Service State - Select an option from the drop-down menu. The available options are IS, OOS.

      • MAC Address—Displays the MAC address of RP0/RP1.
      • IPv6 —Enter the IPv6 address assigned to RP0/RP1.
      • IPv6 Prefix Length—Enter the prefix length for the provisioned IPv6 address. The value must be between 1 and 128.
      • EMS Interface --- Displays the IP address of RP0/RP1 that connects to a device via serial or LAN port.
      • EMS Submask --- Displays the subnet mask corresponding to the EMS IP.
      • EMS Service State - Select an option from the drop-down menu. The available options are IS, OOS.

      • Craft Interface --- Displays the IP address of RP0/RP1 that connects to a device via serial or LAN port.
      • Craft Submask --- Displays the subnet mask corresponding to the Craft IP.
      • Craft Service State --- Select an option from the drop-down menu. The available options are IS,OOS.

      Note

       

      If your node is having dual RP, then you must configure both the RP0 and RP1 to avoid discrepancy while performing switchover.

    4. In the Gateway area, complete the following information :

      • IPv4 --- Enter a unique IPv4 address.
      • IPv6 --- Enter a unique IPv6 address.
      • IPv6 Prefix Length --- Enter the prefix length for the provisioned IPv6 address. The value must be between 1 and 128.

    Step 3

    Click the Next button to save the changes and open the OTN Topology pane.

    Step 4

    Click Close to save the changes and close the Node Configuration Wizard.

    Step 5

    In the loopback interface area, complete the following :

    • Interface Type/ID --- Displays the loopback0 and it cannot be modified.
    • IP Address --- Configure the Loopback IP Address.
    • Sub Net Mask -- Enter the Subnet Mask for the Loopback IP Address.
    You cannot delete the Loopback information once configured.

    Step 6

    In the RSVP-Interface List area, the details include:

    • Interface Name - displays the interface.

    • RSVP State - choose an option from the drop-down menu. The available options are - Disable and Enable.

    Step 7

    If you want to create the controller, configure GCC interface, MPLS-TE, RSVP-TE on a particular card, complete the following :

    1. In the Port Controller Configuration area, click the Slot to see the already configured ports with its corresponding data. The ports which are not configured on the node display the value None.

    2. Displays the Port number.

    3. Displays the Service State for the port. The states can be --- IS-NR, OOS-AU.

    4. Select a Service Type from the drop-down list to create the controller.

    5. Check the GCC0/GCC1 check box if you want to enable GCC on OTU or ODU in each slot.

    6. Check the Unnumbered GCC0/1 check box to assign unnumbered loopback only on the enabled GCC interfaces.

    7. Check the MPLS check box if you want to configure the specific controller as a part of MPLS configuration. Complete Configure an MPLS-TE Instance Using CTC as needed.

    8. Check the RSVP check box if you want to configure the specific controller as a part of RSVP configuration. Complete Configure a RSVP-TE Instance Using CTC as needed.

    9. Configure the value of Admin weight only if MPLS is enabled. This weight ranges from 0 to 65535.

      The default value of Admin weight is 0.

    10. Configure the value of TTI Mode only if MPLS is enabled.

    11. Configure the value of Timer only if RSVP is enabled. It ranges from 180 to 86400 seconds.

    12. Configure the value of Missed messages field only if RSVP is enabled. It displays the number of refresh optical missed messages and ranges from 1 to 8.

    Step 8

    If you want to delete the controller, perform the following:

    1. Click the Next button to save the current changes and open the OTN Topology pane.

    2. Choose the Service Type as None to delete the already configured controller.

    3. Click the Previous button to save the changes and display the previous configuration pane.

    4. Click the Close button to save the changes and close the Node Configuration Wizard.

      Delete the controller manually from the MPLS or RSVP, If you have configured the controller as part of MPLS or RSVP configuration.

    Step 9

    In the OSPF area, Complete the following :

    • OSPF Process ID --- Displays OTN and cannot be modified.
    • Router ID --- Displays the virtual IP of the node.
    • Enable NSR --- Displays the field as checked once the OSPF process ID and Router ID is created.
    • Enable NSF --- Displays the field as checked once the OSPF process ID and Router ID is created
    • Add --- Click this button to create an OSPF entry.
    • Delete --- Click this button to delete a selected OSPF entry.
    • Interface --- Choose the OSPF interface from the drop-down list.
    • Area ID --- Displays area ID as 0.
    • Cost --- Enter the cost used by OSPF routers to calculate the shortest path.
    • Passive --- Choose the state of the OSPF interface from the drop-down list. The available options are True and False.

    Step 10

    Click Previous to save the current changes and display the previous configuration pane.

    Step 11

    Click Close to save the changes and close the Node Configuration Wizard.

    Stop. You have completed this procedure.


    Configure Interoperability Between NCS 4000 and MSTP Nodes

    Purpose

    Link Management Protocol (LMP) is used to support interoperability between the NCS 4000 node and the MSTP node. To support interoperability, this procedure provisions an LMP between an NCS 4000 node and MSTP nodes followed by the creation of an GMPLS OCH trail circuit between two NCS 4000 nodes.

    Tools/Equipment None
    Prerequisite Procedures

    "Login to CTC" in System Setup and Software Installation Guide for Cisco NCS 4000 Series.

    Required/As Needed As needed
    Onsite/Remote Onsite or remote
    Security Level Provisioning or higher

    Procedure


    Step 1

    To provision an LMP between an NCS 4000 and MSTP node, complete Create an Local UNI LMP Using CTC.

    Step 2

    To provision a TE link, complete Enabling GMPLS Using CTC.

    Step 3

    To provision a GMPLS OCH trail circuit between two NCS 4000 nodes, complete Configure GMPLS OCH Trail Between NCS 4000 Nodes

    Stop. You have completed this procedure.


    Configure GMPLS OCH Trail Between NCS 4000 Nodes

    Purpose

    This task provisions a GMPLS OCH trail circuit between NCS 4000 nodes that are connected to MSTP nodes.

    Tools/Equipment None
    Prerequisite Procedures
    Required/As Needed As needed
    Onsite/Remote Onsite or remote
    Security Level Provisioning or higher

    Procedure


    Step 1

    In the network view, click the DWDM Functional View icon in the toolbar. The DWDM Network Functional View <Circuit Maintenance> opens.

    Alternatively, you could perform the following steps in the network view:
    • Click Circuits > Circuits tabs.

    • Click Create. The Create Circuit dialog appears.

    • Click WSON. The DWDM Network Functional View <Circuit Maintenance> opens.

    Step 2

    From the Change Perspective drop-down list in the toolbar, choose Circuit Creation. The Circuit Creation view opens.

    Step 3

    Select the source node from where the OCH trail circuit must originate.

    Step 4

    Right-click and select the originating port on the source node.

    Step 5

    Select the destination node where the OCH trail circuit must terminate.

    Step 6

    Right-click and select the terminating port on the destination node.

    The GMPLS/WSON OCH_TRAIL Selection window appears.

    Step 7

    Specify a name and label for the circuit.

    Step 8

    Set the validation mode and acceptance threshold.

    Step 9

    Check the Wavelength Configuration check box to configure an explicit wavelength for the circuit.

    Step 10

    Check the IS checkbox to place the OCH trail circuit in service after creation. It is checked by default.

    Step 11

    Click Create.

    All the configurations are applied to the circuit. The circuit appears in the Circuits tab in the Network Data pane.

    Step 12

    Return to your originating procedure.