FXOS Faults

This chapter provides information about the faults that may be raised in FXOS.

fltFabricComputeSlotEpMispla cedInChassisSlot

Fault Code: F0156

Message

Server, vendor([vendor]), model([model]), serial([serial]) in slot [chassisId]/[slotId] presence: [presence]

Explanation

This fault typically occurs when Cisco FPR Manager detects a server in a chassis slot that does not match what was previously equipped in the slot.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the previous server was intentionally removed and a new one was inserted, reacknowledge the server.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: server-moved
mibFaultCode: 156
mibFaultName: fltFabricComputeSlotEpMisplacedInChassisSlot
moClass: fabric:ComputeSlotEp
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]

fltFabricComputeSlotEpServerIdentificationProblem

Fault Code: F0157

Message

Problem identifying server in slot [chassisId]/[slotId]

Explanation

This fault typically occurs when Cisco FPR Manager encountered a problem identifying the server in a chassis slot.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove and reinsert the server.

Step 2blank.gif Reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: server-identification-problem
mibFaultCode: 157
mibFaultName: fltFabricComputeSlotEpServerIdentificationProblem
moClass: fabric:ComputeSlotEp
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]

fltVnicEtherConfig-failed

Fault Code: F0169

Message

Eth vNIC [name], service profile [name] failed to apply configuration

Explanation

This fault typically occurs when Cisco FPR Manager could not place the vNIC on the vCon.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the server was successfully discovered.

Step 2blank.gif Verify that the correct type of adapters are installed on the server.

Step 3blank.gif Confirm that the vCon assignment is correct.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: configuration-failed
mibFaultCode: 169
mibFaultName: fltVnicEtherConfigFailed
moClass: vnic:Ether
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]

fltProcessorUnitInoperable

Fault Code: F0174

Message

Processor [id] on server [chassisId]/[slotId] operability: [operability]

Explanation

This fault occurs in the unlikely event that processor is inoperable.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.

Step 2blank.gif In Cisco FPR Manager, decommission and then recommission the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 174
mibFaultName: fltProcessorUnitInoperable
moClass: processor:Unit
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltProcessorUnitThermalNonCritical

Fault Code: F0175

Message

Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]

Explanation

This fault occurs when the processor temperature on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: thermal-problem
mibFaultCode: 175
mibFaultName: fltProcessorUnitThermalNonCritical
moClass: processor:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltProcessorUnitThermalThresholdCritical

Fault Code: F0176

Message

Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]

Explanation

This fault occurs when the processor temperature on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 176
mibFaultName: fltProcessorUnitThermalThresholdCritical
moClass: processor:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltProcessorUnitThermalThresholdNonRecoverable

Fault Code: F0177

Message

Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal]

Explanation

This fault occurs when the processor temperature on a blade or rack server has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: thermal-problem
mibFaultCode: 177
mibFaultName: fltProcessorUnitThermalThresholdNonRecoverable
moClass: processor:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltProcessorUnitVoltageThresholdNonCritical

Fault Code: F0178

Message

Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]

Explanation

This fault occurs when the processor voltage is out of normal operating range, but hasn’t yet reached a critical stage. Normally the processor recovers itself from this situation

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor the processor for further degradation.

Step 2blank.gif If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.

Step 3blank.gif In Cisco FPR Manager, decommission and then recommission the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: voltage-problem
mibFaultCode: 178
mibFaultName: fltProcessorUnitVoltageThresholdNonCritical
moClass: processor:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltProcessorUnitVoltageThresholdCritical

Fault Code: F0179

Message

Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]

Explanation

This fault occurs when the processor voltage has exceeded the specified hardware voltage rating.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.

Step 2blank.gif In Cisco FPR Manager, decommission and then recommission the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: voltage-problem
mibFaultCode: 179
mibFaultName: fltProcessorUnitVoltageThresholdCritical
moClass: processor:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltProcessorUnitVoltageThresholdNonRecoverable

Fault Code: F0180

Message

Processor [id] on server [chassisId]/[slotId] voltage: [voltage]Processor [id] on server [id] voltage: [voltage]

Explanation

This fault occurs when the processor voltage has exceeded the specified hardware voltage rating and may cause processor hardware damage or jeopardy.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the fault occurs on a blade server processor, remove the server from the chassis and then reinsert it.

Step 2blank.gif In Cisco FPR Manager, decommission and then recommission the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: voltage-problem
mibFaultCode: 180
mibFaultName: fltProcessorUnitVoltageThresholdNonRecoverable
moClass: processor:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltStorageLocalDiskInoperable

Fault Code: F0181

Message

Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

This fault occurs when the local disk has become inoperable.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Insert the disk in a supported slot.

Step 2blank.gif Remove and reinsert the local disk.

Step 3blank.gif Replace the disk, if an additional disk is available.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 181
mibFaultName: fltStorageLocalDiskInoperable
moClass: storage:LocalDisk
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]

fltStorageItemCapacityExceeded

Fault Code: F0182

Message

Disk usage for partition [name] on fabric interconnect [id] exceeded 70%

Explanation

This fault occurs when the partition disk usage exceeds 70% but is less than 90%.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reduce the partition disk usage to less than 70% by deleting unused and unnecessary files.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: capacity-exceeded
mibFaultCode: 182
mibFaultName: fltStorageItemCapacityExceeded
moClass: storage:Item
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/stor-part-[name]

fltStorageItemCapacityWarning

Fault Code: F0183

Message

Disk usage for partition [name] on fabric interconnect [id] exceeded 90%

Explanation

This fault occurs when the partition disk usage exceeds 90%.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reduce the partition disk usage to less than 90% by deleting unused and unnecessary files.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: capacity-exceeded
mibFaultCode: 183
mibFaultName: fltStorageItemCapacityWarning
moClass: storage:Item
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/stor-part-[name]

fltMemoryUnitDegraded

Fault Code: F0184

Message

DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]

Explanation

This fault occurs when a DIMM is in a degraded operability state. This state typically occurs when an excessive number of correctable ECC errors are reported on the DIMM by the server BIOS.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor the error statistics on the degraded DIMM through Cisco FPR Manager. If the high number of errors persists, there is a high possibility of the DIMM becoming inoperable.

Step 2blank.gif If the DIMM becomes inoperable, replace the DIMM.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: equipment-degraded
mibFaultCode: 184
mibFaultName: fltMemoryUnitDegraded
moClass: memory:Unit
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]

fltMemoryUnitInoperable

Fault Code: F0185

Message

DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability]

Explanation

This fault typically occurs because an above threshold number of correctable or uncorrectable errors has occurred on a DIMM. The DIMM may be inoperable.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the SEL is enabled, review the SEL statistics on the DIMM to determine which threshold was crossed.

Step 2blank.gif If necessary, replace the DIMM.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 185
mibFaultName: fltMemoryUnitInoperable
moClass: memory:Unit
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]

fltMemoryUnitThermalThresholdNonCritical

Fault Code: F0186

Message

DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a memory unit on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: thermal-problem
mibFaultCode: 186
mibFaultName: fltMemoryUnitThermalThresholdNonCritical
moClass: memory:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]

fltMemoryUnitThermalThresholdCritical

Fault Code: F0187

Message

DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a memory unit on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 187
mibFaultName: fltMemoryUnitThermalThresholdCritical
moClass: memory:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]

fltMemoryUnitThermalThresholdNonRecoverable

Fault Code: F0188

Message

DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a memory unit on a blade or rack server has been out of the operating range, and the issue is not recoverable.Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 188
mibFaultName: fltMemoryUnitThermalThresholdNonRecoverable
moClass: memory:Unit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]

fltMemoryArrayVoltageThresholdNonCritical

Fault Code: F0189

Message

Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]

Explanation

This fault occurs when the memory array voltage is out of normal operating range, but hasn’t yet reached a critical stage. Typically the memory array recovers itself from this situation.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the SEL is enabled, look at the SEL statistics on the DIMM to determine which threshold was crossed.

Step 2blank.gif Monitor the memory array for further degradation.

Step 3blank.gif If the fault occurs on a blade server memory array, remove the blade and re-insert into the chassis.

Step 4blank.gif In Cisco FPR Manager, decommission and recommission the server.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: voltage-problem
mibFaultCode: 189
mibFaultName: fltMemoryArrayVoltageThresholdNonCritical
moClass: memory:Array
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]

fltMemoryArrayVoltageThresholdCritical

Fault Code: F0190

Message

Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]

Explanation

This fault occurs when the memory array voltage exceeds the specified hardware voltage rating

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the SEL is enabled, look at the SEL statistics on the DIMM to determine which threshold was crossed.

Step 2blank.gif Monitor the memory array for further degradation.

Step 3blank.gif If the fault occurs on a blade server memory array, remove the blade and re-insert into the chassis.

Step 4blank.gif In Cisco FPR Manager, decommission and recommission the server.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: voltage-problem
mibFaultCode: 190
mibFaultName: fltMemoryArrayVoltageThresholdCritical
moClass: memory:Array
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]

fltMemoryArrayVoltageThresholdNonRecoverable

Fault Code: F0191

Message

Memory array [id] on server [chassisId]/[slotId] voltage: [voltage]Memory array [id] on server [id] voltage: [voltage]

Explanation

This fault occurs when the memory array voltage exceeded the specified hardware voltage rating and potentially memory hardware may be in damage or jeopardy

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the SEL is enabled, review the SEL statistics on the DIMM to determine which threshold was crossed.

Step 2blank.gif Monitor the memory array for further degradation.

Step 3blank.gif If the fault occurs on a blade server memory array, remove the server from the chassis and re-insert it.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: voltage-problem
mibFaultCode: 191
mibFaultName: fltMemoryArrayVoltageThresholdNonRecoverable
moClass: memory:Array
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]

fltAdaptorUnitUnidentifiable-fru

Fault Code: F0200

Message

Adapter [id] in server [id] has unidentified FRUAdapter [id] in server [chassisId]/[slotId] has unidentified FRU

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported adapter. For example, the model, vendor, or revision is not recognized.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that a supported adapter is installed.

Step 2blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: unidentifiable-fru
mibFaultCode: 200
mibFaultName: fltAdaptorUnitUnidentifiableFru
moClass: adaptor:Unit
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]

fltAdaptorUnitMissing

Fault Code: F0203

Message

Adapter [id] in server [id] presence: [presence]Adapter [id] in server [chassisId]/[slotId] presence: [presence]

Explanation

The adaptor is missing. Cisco FPR Manager raises this fault when any of the following scenarios occur:

  • The endpoint reports there is no adapter in the adaptor slot.
  • The endpoint cannot detect or communicate with the adapter in the adaptor slot.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Make sure an adapter is inserted in the adaptor slot in the server.

Step 2blank.gif Check whether the adaptor is connected and configured properly and is running the recommended firmware version.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-missing
mibFaultCode: 203
mibFaultName: fltAdaptorUnitMissing
moClass: adaptor:Unit
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]

fltAdaptorUnitAdaptorReachability

Fault Code: F0206

Message

Adapter [id]/[id] is unreachableAdapter [chassisId]/[slotId]/[id] is unreachable

Explanation

Cisco FPR Manager cannot access the adapter. This fault typically occurs as a result of one of the following issues:

  • The server does not have sufficient power.
  • The I/O module is not functional.
  • The adapter firmware has failed.
  • The adapter is not functional

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.

Step 2blank.gif In Cisco FPR Manager, check the power state of the server.

Step 3blank.gif Verify that the physical server has the same power state.

Step 4blank.gif If the server is off, turn the server on.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: connectivity-problem
mibFaultCode: 206
mibFaultName: fltAdaptorUnitAdaptorReachability
moClass: adaptor:Unit
Type: connectivity
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]

fltAdaptorHostIfLink-down

Fault Code: F0207

Message

Adapter [transport] host interface [id]/[id]/[id] link state: [linkState], Associated external interface link state: [vcAdminState]Adapter [transport] host interface [chassisId]/[slotId]/[id]/[id] link state: [linkState], Associated external interface link state: [vcAdminState]

Explanation

This fault typically occurs as a result of one of the following issues:

  • The fabric interconnect is in End-Host mode, and all uplink ports failed.
  • The server port to which the adapter is pinned failed.
  • A transient error caused the link to fail.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If an associated port is disabled, enable the port.

Step 2blank.gif Check the associated port to ensure it is in up state.

Step 3blank.gif Reacknowledge the server with the adapter that has the failed link.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Step 5blank.gif vnic link state will be down, when its associated external interface is down.The fault should not be displayed regardless if it is administratively disabled or if it is operationally not up(i.e. physical link is detected as down).

Fault Details

Severity: major
Cause: link-down
mibFaultCode: 207
mibFaultName: fltAdaptorHostIfLinkDown
moClass: adaptor:HostIf
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-iscsi-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]

fltAdaptorExtIfLink-down

Fault Code: F0209

Message

Adapter uplink interface [chassisId]/[slotId]/[id]/[id] on security module [slotId] link state: [linkState]. Please check switch blade-facing port status. Resetting security module might be required.

Explanation

The link for a network facing adapter interface is down. Cisco FPR Manager raises this fault when any of the following scenarios occur:

  • Cisco FPR Manager cannot establish and/or validate the adapter’s connectivity to any of the fabric interconnects.
  • The endpoint reports a link down or vNIC down event on the adapter link.
  • The endpoint reports an errored link state or errored vNIC state event on the adapter link.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the adapter is connected, configured properly, and is running the recommended firmware version.

Step 2blank.gif If the server is stuck at discovery, decommission the server and reacknowledge the server slot.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: link-down
mibFaultCode: 209
mibFaultName: fltAdaptorExtIfLinkDown
moClass: adaptor:ExtIf
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]

fltPortPIoLink-down

Fault Code: F0276

Message

[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]

Explanation

This fault occurs when a fabric interconnect port is in link-down state. This state impacts the traffic destined for the port.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the physical link is properly connected between the fabric interconnect and the peer component.

Step 2blank.gif Verify that the configuration on the peer entity is properly configured and matches the fabric interconnect port configuration.

Step 3blank.gif Unconfigure and re-configure the port.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: link-down
mibFaultCode: 276
mibFaultName: fltPortPIoLinkDown
moClass: port:PIo
Type: network
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltPortPIoFailed

Fault Code: F0277

Message

[transport] port [portId] on chassis [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]

Explanation

This fault is raised on fabric interconnect ports and on server-facing ports on an IOM or a FEX module when FPRM detects that the port is not up and in failed state while it is expected to be up since it has been enabled by user and there is no known hardware failure or missing SFP issue and port license is valid. Additional reason is displayed by the fault description string.

Recommended Action

If you see this fault, Corrective action maybe taken based on reason information in the fault description whenever such a reason is displayed. If the fault description displays reason as "ENM source pinning failed" then it means that the fabric interconnect is operating in End-host Node Mode and the uplink port that this server facing port is pinned to is down or does not have appropriate VLAN configured. In case of such an error for an appliance port check the VLAN configuration on uplink port. A VLAN with same id as the one on the appliance port will also need to be configured on the uplink port. After setting the configuration right if you still see the fault then create a show tech-support file for Cisco FPR Manager and the chassis or FEX module, and then contact Cisco TAC.

Fault Details

Severity: major
Cause: port-failed
mibFaultCode: 277
mibFaultName: fltPortPIoFailed
moClass: port:PIo
Type: network
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltPortPIoHardware-failure

Fault Code: F0278

Message

[transport] port [portId] on chassis [id] oper state: [operState], reason: hardware-failure[transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState], reason: hardware-failure[transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState], reason: hardware-failure

Explanation

This fault is raised on fabric interconnect ports and server-facing ports on an IOM or a FEX module when the system detects a hardware failure.

Recommended Action

If you see this fault, create a show tech-support file for Cisco FPR Manager and the chassis or FEX module, and then contact Cisco TAC.

Fault Details

Severity: major
Cause: port-failed
mibFaultCode: 278
mibFaultName: fltPortPIoHardwareFailure
moClass: port:PIo
Type: network
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltPortPIoSfp-not-present

Fault Code: F0279

Message

[transport] port [portId] on chassis [id] oper state: [operState][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] oper state: [operState][transport] port [slotId]/[portId] on fabric interconnect [id] oper state: [operState]

Explanation

When a fabric interconnect port is not in an unconfigured state, an SFP is required for its operation. This fault is raised to indicate that the SFP is missing from a configured port.

Recommended Action

If you see this fault, insert a supported SFP into the port on the fabric interconnect. A list of supported SFPs can be found on www.Cisco.com.

Fault Details

Severity: info
Cause: port-failed
mibFaultCode: 279
mibFaultName: fltPortPIoSfpNotPresent
moClass: port:PIo
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltFabricExternalPcDown

Fault Code: F0282

Message

[type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual][type] port-channel [portId] on fabric interconnect [switchId] oper state: [operState], reason: [stateQual]

Explanation

This fault typically occurs when a fabric interconnect reports that a fabric port channel is operationally down.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the member ports in the fabric port channel are administratively up and operational. Check the link connectivity for each port.

Step 2blank.gif If connectivity seems correct, check the operational states on the peer switch ports of the port channel members.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: operational-state-down
mibFaultCode: 282
mibFaultName: fltFabricExternalPcDown
moClass: fabric:ExternalPc
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]
Affected MO: fabric/eth-estc/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]
Affected MO: fabric/lan/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/lan/net-group-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]
Affected MO: fabric/san/[id]/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/[id]/net-[name]/pc-switch-[switchId]-pc-[portId]
Affected MO: fabric/san/[id]/pc-[portId]
Affected MO: fabric/san/net-[name]/fcoepc-switch-[switchId]-fcoepc-[portId]
Affected MO: fabric/san/net-[name]/pc-switch-[switchId]-pc-[portId]

fltDcxVcDown

Fault Code: F0283

Message

[transport] VIF [id] on server [chassisId] / [slotId] of switch [switchId] down, reason: [stateQual][transport] VIF [id] on server [id] of switch [switchId] down, reason: [stateQual]

Explanation

This fault typically occurs when a fabric interconnect reports one of the following connectivity states for a virtual interface:

  • Down
  • Errored
  • Unavailable

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the uplink physical interface is up.

Step 2blank.gif Check the associated port to ensure it is in up state.

Step 3blank.gif If the vNIC/vHBA is configured for a pin group, verify that the pin group targets are configured correctly.

Step 4blank.gif In the Network Control Policy for the vNIC, verify that the ’Action on Uplink Fail’ field is set to ’warning’.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: link-down
mibFaultCode: 283
mibFaultName: fltDcxVcDown
moClass: dcx:Vc
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]

fltNetworkElementInoperable

Fault Code: F0291

Message

Fabric Interconnect [id] operability: [operability]

Explanation

This fault typically occurs when the fabric interconnect cluster controller reports that the membership state of the fabric interconnect is down, indicating that the fabric interconnect is inoperable.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that both fabric interconnects in the cluster are running the same Kernel and System software versions.

Step 2blank.gif Verify that the fabric interconnects software version and the Cisco FPR Manager software versions are the same.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-inoperable
mibFaultCode: 291
mibFaultName: fltNetworkElementInoperable
moClass: network:Element
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]

fltMgmtEntityDegraded

Fault Code: F0293

Message

Fabric Interconnect [id], HA Cluster interconnect link failure

Explanation

This fault occurs when one of the cluster links (either L1 or L2) of a fabric interconnect is not operationally up. This issue impacts the full HA functionality of the fabric interconnect cluster.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that both L1 and L2 links are properly connected between the fabric interconnects.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: link-down
mibFaultCode: 293
mibFaultName: fltMgmtEntityDegraded
moClass: mgmt:Entity
Type: network
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltMgmtEntityDown

Fault Code: F0294

Message

Fabric Interconnect [id], HA Cluster interconnect total link failure

Explanation

This fault occurs when both cluster links (L1 and L2) of the fabric interconnects are in a link-down state. This issue impacts the full HA functionality of the fabric interconnect cluster.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that both L1 and L2 links are properly connected between the fabric interconnects.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: link-down
mibFaultCode: 294
mibFaultName: fltMgmtEntityDown
moClass: mgmt:Entity
Type: network
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltDcxNsFailed

Fault Code: F0304

Message

Server [chassisId]/[slotId] (service profile: [assignedToDn]) virtual network interface allocation failed.Server [id] (service profile: [assignedToDn]) virtual network interface allocation failed.

Explanation

The adapter’s vif-namespace activation failed due to insufficient resources. Cisco FPR Manager raises this fault when the number of deployed VIF resources exceeds the maximum VIF resources available on the adapter connected to the fabric interconnect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the NS "size" and "used" resources to determine by how many vNICs the adapter exceeded the maximum.

Step 2blank.gif Unconfigure or delete all vNICs on the adapter above the maximum number.

Step 3blank.gif Add additional fabric uplinks from the IOM to the corresponding fabric interconnect and reacknowledge the chassis. This increases the "NS size" on the adapter.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: insufficient-resources
mibFaultCode: 304
mibFaultName: fltDcxNsFailed
moClass: dcx:Ns
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/dcxns-[switchId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/dcxns-[switchId]

fltComputePhysicalInsufficientlyEquipped

Fault Code: F0305

Message

Server [id] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adapters

Explanation

This fault typically occurs because Cisco FPR Manager has detected that the server has an insufficient number of DIMMs, CPUs, and/or adapters.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the DIMMs are installed in a supported configuration.

Step 2blank.gif Verify that an adapter and CPU are installed.

Step 3blank.gif Reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: insufficiently-equipped
mibFaultCode: 305
mibFaultName: fltComputePhysicalInsufficientlyEquipped
moClass: compute:Physical
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalIdentityUnestablishable

Fault Code: F0306

Message

Server [id] (service profile: [assignedToDn]) has an invalid FRUServer [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRU

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported server or CPU.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that a supported server and/or CPU is installed.

Step 2blank.gif Verify that the Cisco FPR Manager capability catalog is up to date.

Step 3blank.gif Reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: identity-unestablishable
mibFaultCode: 306
mibFaultName: fltComputePhysicalIdentityUnestablishable
moClass: compute:Physical
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputeBoardPowerError

Fault Code: F0310

Message

Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [id] (service profile: [assignedToDn]) power: [operPower]

Explanation

This fault typically occurs when the server power sensors have detected a problem.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Make sure that the server is correctly installed in the chassis and that all cables are secure.

Step 2blank.gif If you reinstalled the server, reacknowledge it.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-problem
mibFaultCode: 310
mibFaultName: fltComputeBoardPowerError
moClass: compute:Board
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board

fltComputePhysicalPowerProblem

Fault Code: F0311

Message

Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]

Explanation

This fault typically occurs when the server power sensors have detected a problem.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Make sure that the server is correctly installed in the chassis and that all cables are secure.

Step 2blank.gif If you reinstalled the server, reacknowledge it.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-problem
mibFaultCode: 311
mibFaultName: fltComputePhysicalPowerProblem
moClass: compute:Physical
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalThermalProblem

Fault Code: F0312

Message

Server [id] (service profile: [assignedToDn]) oper state: [operState]Server [chassisId]/[slotId] (service profile: [assignedToDn]) oper state: [operState]

Explanation

This fault typically occurs when the server thermal sensors have detected a problem.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Make sure that the server fans are working properly.

Step 2blank.gif Wait for 24 hours to see if the problem resolves itself.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: thermal-problem
mibFaultCode: 312
mibFaultName: fltComputePhysicalThermalProblem
moClass: compute:Physical
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalBiosPostTimeout

Fault Code: F0313

Message

Server [id] (service profile: [assignedToDn]) BIOS failed power-on self testBlade [chassisId]/[slotId] (service profile: [assignedToDn]) BIOS failed power-on self test

Explanation

This fault typically occurs when the server has encountered a diagnostic failure.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.

Step 2blank.gif Reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-inoperable
mibFaultCode: 313
mibFaultName: fltComputePhysicalBiosPostTimeout
moClass: compute:Physical
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalDiscoveryFailed

Fault Code: F0314

Message

Server [id] (service profile: [assignedToDn]) discovery: [discovery]Server [chassisId]/[slotId] (service profile: [assignedToDn]) discovery: [discovery]

Explanation

This fault typically occurs for one of the following reasons:

  • The shallow discovery that occurs when the server associated with service profile failed.
  • The server is down.
  • The data path is not working.
  • Cisco FPR Manager cannot communicate with the CIMC on the server.
  • The server cannot communicate with the fabric interconnect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the FSM tab and the current state of the server and any FSM operations.

Step 2blank.gif Check the error descriptions and see if any server components indicate a failure.

Step 3blank.gif If the server or a server component has failed, do the following:

a.blank.gif Check the operational state of the server.

b.blank.gif If the server is not operable, re-acknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: discovery-failed
mibFaultCode: 314
mibFaultName: fltComputePhysicalDiscoveryFailed
moClass: compute:Physical
Type: operational
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalAssociationFailed

Fault Code: F0315

Message

Service profile [assignedToDn] failed to associate with server [id]Service profile [assignedToDn] failed to associate with server [chassisId]/[slotId]

Explanation

This fault typically occurs for one of the following reasons:

  • The service profile could not be associated with the server.
  • The server is down.
  • The data path is not working.
  • Cisco FPR Manager cannot communicate with one or more of the fabric interconnect, the server, or a component on the server.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the FSM tab and the current state of the server and any FSM operations.

Step 2blank.gif If the server is stuck in an inappropriate state, such as booting, power cycle the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: association-failed
mibFaultCode: 315
mibFaultName: fltComputePhysicalAssociationFailed
moClass: compute:Physical
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalInoperable

Fault Code: F0317

Message

Server [id] (service profile: [assignedToDn]) health: [operability]Server [chassisId]/[slotId] (service profile: [assignedToDn]) health: [operability]

Explanation

This fault typically occurs when the server has encountered a diagnostic failure.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the POST results for the server.In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.

Step 2blank.gif Reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 317
mibFaultName: fltComputePhysicalInoperable
moClass: compute:Physical
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalUnassignedMissing

Fault Code: F0318

Message

Server [id] (no profile) missingServer [chassisId]/[slotId] (no profile) missing

Explanation

This fault typically occurs when the server, which is not associated with a service profile, was previously physically inserted in the slot, but cannot be detected by Cisco FPR Manager.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the server is physically present in the slot, remove and then reinsert it.

Step 2blank.gif If the server is not physically present in the slot, insert it.

Step 3blank.gif Reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: equipment-missing
mibFaultCode: 318
mibFaultName: fltComputePhysicalUnassignedMissing
moClass: compute:Physical
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalAssignedMissing

Fault Code: F0319

Message

Server [id] (service profile: [assignedToDn]) missingServer [chassisId]/[slotId] (service profile: [assignedToDn]) missing

Explanation

This fault typically occurs when the server, which is associated with a service profile, was previously physically inserted in the slot, but cannot be detected by Cisco FPR Manager.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the server is physically present in the slot, remove and then reinsert it.

Step 2blank.gif If the server is not physically present in the slot, reinsert it.

Step 3blank.gif Reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-missing
mibFaultCode: 319
mibFaultName: fltComputePhysicalAssignedMissing
moClass: compute:Physical
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalUnidentified

Fault Code: F0320

Message

Server [id] (service profile: [assignedToDn]) has an invalid FRU: [presence]Server [chassisId]/[slotId] (service profile: [assignedToDn]) has an invalid FRU: [presence]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported server or CPU.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that a supported server and/or CPU is installed.

Step 2blank.gif Verify that the Cisco FPR Manager capability catalog is up to date.

Step 3blank.gif Reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: identity-unestablishable
mibFaultCode: 320
mibFaultName: fltComputePhysicalUnidentified
moClass: compute:Physical
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalUnassignedInaccessible

Fault Code: F0321

Message

Server [id] (no profile) inaccessibleServer [chassisId]/[slotId] (no profile) inaccessible

Explanation

This fault typically occurs when the server, which is not associated with a service profile, has lost connection to the fabric interconnects. This fault occurs if there are communication issues between the server CIMC and the fabric interconnects.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.

Step 2blank.gif If the fault does not clear after a brief time, remove the server and then reinsert it.

Step 3blank.gif Reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-inaccessible
mibFaultCode: 321
mibFaultName: fltComputePhysicalUnassignedInaccessible
moClass: compute:Physical
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalAssignedInaccessible

Fault Code: F0322

Message

Server [id] (service profile: [assignedToDn]) inaccessibleServer [chassisId]/[slotId] (service profile: [assignedToDn]) inaccessible

Explanation

This fault typically occurs when the server, which is associated with a service profile, has lost connection to the fabric interconnects. This fault occurs if there are communication issues between the server CIMC and the fabric interconnects.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.

Step 2blank.gif If the fault does not clear after a brief time, remove the server and then reinsert it.

Step 3blank.gif Reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: equipment-inaccessible
mibFaultCode: 322
mibFaultName: fltComputePhysicalAssignedInaccessible
moClass: compute:Physical
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltLsServerFailed

Fault Code: F0324

Message

Service profile [name] failed

Explanation

Server has failed. This fault typically occurs if the adapter power on self-test results in major and critical errors.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: server-failed
mibFaultCode: 324
mibFaultName: fltLsServerFailed
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerDiscoveryFailed

Fault Code: F0326

Message

Service profile [name] discovery failed

Explanation

The shallow discovery that occurs when the server associated with service profile fails. If the server is up and the data path is working, this fault typically occurs as a result of one of the following issues:

  • Cisco FPR Manager cannot communicate with the CIMC on the server.
  • The server cannot communicate with the fabric interconnect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the FSM tab and view the current state of the server and any FSM operations.

Step 2blank.gif Check the error descriptions and see if any server components indicate a failure.

Step 3blank.gif If the server or a server component has failed, do the following:

a.blank.gif Check the operational state of the server.

b.blank.gif If the server is not operable, reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: discovery-failed
mibFaultCode: 326
mibFaultName: fltLsServerDiscoveryFailed
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerConfigFailure

Fault Code: F0327

Message

Service profile [name] configuration failed due to [configQualifier]

Explanation

The named configuration qualifier is not available. This fault typically occurs because Cisco FPR Manager cannot successfully deploy the service profile due to a lack of resources that meet the named qualifier. For example, this fault can occur if the following occurs:

  • The service profile is configured for a server adapter with vHBAs, and the adapter on the server does not support vHBAs.
  • The service profile is created from a template which includes a server pool, and the server pool is empty.
  • The local disk configuration policy in the service profile specifies the No Local Storage mode, but the server contains local disks.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the status of the server pool associated with the service profile. If the pool is empty, add more blade servers to it.

Step 2blank.gif Check the state of the server and ensure that it is in either the discovered or unassociated state.

Step 3blank.gif If the server is associated or undiscovered, do one of the following:

–blank.gif Discover the server.

–blank.gif Disassociate the server from the current service profile.

–blank.gif Select another server to associate with the service profile.

Step 4blank.gif Review each policy in the service profile and verify that the selected server meets the requirements in the policy.

Step 5blank.gif If the server does not meet the requirements of the service profile, do one of the following:

–blank.gif Modify the service profile to match the server.

–blank.gif Select another server that does meet the requirements to associate with the service profile.

Step 6blank.gif If you can verify that the server meets the requirements of the service profile, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: configuration-failure
mibFaultCode: 327
mibFaultName: fltLsServerConfigFailure
moClass: ls:Server
Type: server
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerMaintenanceFailed

Fault Code: F0329

Message

Service profile [name] maintenance failed

Explanation

Cisco FPR Manager currently does not use this fault.

Recommended Action

If you see this fault, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: maintenance-failed
mibFaultCode: 329
mibFaultName: fltLsServerMaintenanceFailed
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerRemoved

Fault Code: F0330

Message

Service profile [name] underlying resource removed

Explanation

Cisco FPR Manager cannot access the server associated with the service profile. This fault typically occurs as a result of one of the following issues:

  • The server has been physically removed from the slot.
  • The server is not available.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the server was removed from the slot, reinsert the server in the slot.

Step 2blank.gif If the server was not removed, remove and reinsert the server.NOTE: If the server is operable, this action can be disruptive to current operations.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-removed
mibFaultCode: 330
mibFaultName: fltLsServerRemoved
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerInaccessible

Fault Code: F0331

Message

Service profile [name] cannot be accessed

Explanation

Cisco FPR Manager cannot communicate with the CIMC on the server. This fault typically occurs as a result of one of the following issues:

  • The server port or ports have failed.
  • The I/O module is offline.
  • The BMC has failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If Cisco FPR Manager shows that the CIMC is down, physically reseat the server.

Step 2blank.gif If Cisco FPR Manager shows that the server ports have failed, attempt to enable them.

Step 3blank.gif If the I/O module is offline, check for faults on that component.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: server-inaccessible
mibFaultCode: 331
mibFaultName: fltLsServerInaccessible
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerAssociationFailed

Fault Code: F0332

Message

Service profile [name] association failed for [pnDn]

Explanation

The service profile could not be associated with the server. This fault typically occurs because Cisco FPR Manager cannot communicate with one or more of the following:

  • Fabric interconnect
  • CIMC on the server
  • SAS controller driver
  • Server

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the FSM tab for the server and service profile to determine why the association failed.

Step 2blank.gif If the server is stuck in an inappropriate state, such as booting, power cycle the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: association-failed
mibFaultCode: 332
mibFaultName: fltLsServerAssociationFailed
moClass: ls:Server
Type: server
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerUnassociated

Fault Code: F0334

Message

Service profile [name] is not associated

Explanation

The service profile has not yet been associated with a server or a server pool. This fault typically occurs as a result of one of the following issues:

  • There is no acceptable server in the server pool.
  • The association failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If you did not intend to associate the service profile, ignore the fault.

Step 2blank.gif If you did intend to associate the service profile, check the association failure fault.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: unassociated
mibFaultCode: 334
mibFaultName: fltLsServerUnassociated
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsServerServer-unfulfilled

Fault Code: F0337

Message

Server [pnDn] does not fulfill Service profile [name] due to [configQualifier]

Explanation

The server no longer meets the qualification requirements of the service profile. This fault typically occurs as a result of one of the following issues:

  • The server has been physically changed.
  • A required component of the server has failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the server inventory compare to the service profile qualifications.

Step 2blank.gif If the server inventory does not match the service profile qualifications, do one of the following:

–blank.gif Associate the server with a different service profile.

–blank.gif Ensure the server has sufficient resources to qualify for the current service profile.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: server-failed
mibFaultCode: 337
mibFaultName: fltLsServerServerUnfulfilled
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltEtherSwitchIntFIoSatellite-connection-absent

Fault Code: F0367

Message

No link between IOM port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]

Explanation

This fault is raised when an I/O module fabric port, which links the I/O module port and the fabric interconnect, is not functional

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify the fabric interconnect-chassis topology. Make sure each I/O module is connected to only one fabric interconnect.

Step 2blank.gif Ensure that the fabric interconnect server port is configured and enabled.

Step 3blank.gif Ensure that the links are plugged in properly and reacknowledge the chassis.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: satellite-connection-absent
mibFaultCode: 367
mibFaultName: fltEtherSwitchIntFIoSatelliteConnectionAbsent
moClass: ether:SwitchIntFIo
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltEtherSwitchIntFIoSatellite-wiring-problem

Fault Code: F0368

Message

Invalid connection between IOM port [chassisId]/[slotId]/[portId] and fabric interconnect [switchId]:[peerSlotId]/[peerPortId]

Explanation

This fault typically occurs as a result of a satellite wiring problem on the network-facing interface of an I/O module and Cisco FPR Manager detects that at least one IOM uplink is misconnected to one of the fabric interconnect ports.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify the fabric interconnect-chassis topology. Make sure each I/O module is connected to only one fabric interconnect.

Step 2blank.gif Ensure that the links are plugged in properly and re-acknowledge the chassis.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: satellite-mis-connected
mibFaultCode: 368
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringProblem
moClass: ether:SwitchIntFIo
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltEquipmentPsuPowerSupplyProblem

Fault Code: F0369

Message

Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]

Explanation

This fault typically occurs when Cisco FPR Manager detects a problem with a power supply unit in a chassis, fabric interconnect or a FEX. For example, the PSU is not functional.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the power cord is properly connected to the PSU and the power source.

Step 2blank.gif Verify that the power source is 220 volts.

Step 3blank.gif Verify that the PSU is properly installed in the chassis or fabric interconnect.

Step 4blank.gif Remove the PSU and reinstall it.

Step 5blank.gif Replace the PSU.

Step 6blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-problem
mibFaultCode: 369
mibFaultName: fltEquipmentPsuPowerSupplyProblem
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentFanDegraded

Fault Code: F0371

Message

Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]

Explanation

This fault occurs when one or more fans in a fan module are not operational, but at least one fan is operational.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the fan module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide and ensure the fan module has adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace the faulty fan modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: equipment-degraded
mibFaultCode: 371
mibFaultName: fltEquipmentFanDegraded
moClass: equipment:Fan
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]

fltEquipmentFanInoperable

Fault Code: F0373

Message

Fan [id] in Fan Module [tray]-[id] under chassis [id] operability: [operability]Fan [id] in fabric interconnect [id] operability: [operability]Fan [id] in fex [id] operability: [operability]Fan [id] in Fan Module [tray]-[id] under server [id] operability: [operability]

Explanation

This fault occurs if a fan is not operational.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove fan module and re-install the fan module again. Remove only one fan module at a time.

Step 2blank.gif Replace fan module with a different fan module

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 373
mibFaultName: fltEquipmentFanInoperable
moClass: equipment:Fan
Type: equipment
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]

fltEquipmentPsuInoperable

Fault Code: F0374

Message

Power supply [id] in chassis [id] operability: [operability]Power supply [id] in fabric interconnect [id] operability: [operability]Power supply [id] in fex [id] operability: [operability]Power supply [id] in server [id] operability: [operability]

Explanation

This fault typically occurs when Cisco FPR Manager detects a problem with a power supply unit in a chassis, fabric interconnect or a FEX. For example, the PSU is not functional.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the power cord is properly connected to the PSU and the power source.

Step 2blank.gif Verify that the power source is 220 volts.

Step 3blank.gif Verify that the PSU is properly installed in the chassis or fabric interconnect.

Step 4blank.gif Remove the PSU and reinstall it.

Step 5blank.gif Replace the PSU.

Step 6blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 374
mibFaultName: fltEquipmentPsuInoperable
moClass: equipment:Psu
Type: equipment
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentIOCardRemoved

Fault Code: F0376

Message

[side] IOM [chassisId]/[id] ([switchId]) is removed

Explanation

This fault typically occurs because an I/O module is removed from the chassis. In a cluster configuration, the chassis fails over to the other I/O module. For a standalone configuration, the chassis associated with the I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the I/O module.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reinsert the I/O module and configure the fabric-interconnect ports connected to it as server ports and wait a few minutes to see if the fault clears.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-removed
mibFaultCode: 376
mibFaultName: fltEquipmentIOCardRemoved
moClass: equipment:IOCard
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentFanModuleMissing

Fault Code: F0377

Message

Fan module [tray]-[id] in chassis [id] presence: [presence]Fan module [tray]-[id] in server [id] presence: [presence]Fan module [tray]-[id] in fabric interconnect [id] presence: [presence]

Explanation

This fault occurs if a fan Module slot is not equipped or removed from its slot

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the reported slot is empty, insert a fan module into the slot.

Step 2blank.gif If the reported slot contains a fan module, remove and reinsert the fan module.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-missing
mibFaultCode: 377
mibFaultName: fltEquipmentFanModuleMissing
moClass: equipment:FanModule
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]

fltEquipmentPsuMissing

Fault Code: F0378

Message

Power supply [id] in chassis [id] presence: [presence]Power supply [id] in fabric interconnect [id] presence: [presence]Power supply [id] in fex [id] presence: [presence]Power supply [id] in server [id] presence: [presence]

Explanation

This fault typically occurs when Cisco FPR Manager detects a problem with a power supply unit in a chassis, fabric interconnect, or a FEX. For example, the PSU is missing.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the PSU is physically present in the slot, remove and then reinsert it.

Step 2blank.gif If the PSU is not physically present in the slot, insert a new PSU.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-missing
mibFaultCode: 378
mibFaultName: fltEquipmentPsuMissing
moClass: equipment:Psu
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentIOCardThermalProblem

Fault Code: F0379

Message

[side] IOM [chassisId]/[id] ([switchId]) operState: [operState]

Explanation

This fault occurs when there is a thermal problem on an I/O module. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty I/O modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 379
mibFaultName: fltEquipmentIOCardThermalProblem
moClass: equipment:IOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentFanModuleThermalThresholdNonCritical

Fault Code: F0380

Message

Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a fan module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the fan module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty fan modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: thermal-problem
mibFaultCode: 380
mibFaultName: fltEquipmentFanModuleThermalThresholdNonCritical
moClass: equipment:FanModule
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]

fltEquipmentPsuThermalThresholdNonCritical

Fault Code: F0381

Message

Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a PSU module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the PSU module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty PSU modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: thermal-problem
mibFaultCode: 381
mibFaultName: fltEquipmentPsuThermalThresholdNonCritical
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentFanModuleThermalThresholdCritical

Fault Code: F0382

Message

Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a fan module has exceeded a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the fan module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty fan modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 382
mibFaultName: fltEquipmentFanModuleThermalThresholdCritical
moClass: equipment:FanModule
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]

fltEquipmentPsuThermalThresholdCritical

Fault Code: F0383

Message

Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a PSU module has exceeded a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the PSU module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty PSU modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 383
mibFaultName: fltEquipmentPsuThermalThresholdCritical
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentFanModuleThermalThresholdNonRecoverable

Fault Code: F0384

Message

Fan module [tray]-[id] in chassis [id] temperature: [thermal]Fan module [tray]-[id] in server [id] temperature: [thermal]Fan module [tray]-[id] in fabric interconnect [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a fan module has been out of operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the fan module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the fan modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty fan modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 384
mibFaultName: fltEquipmentFanModuleThermalThresholdNonRecoverable
moClass: equipment:FanModule
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]

fltEquipmentPsuThermalThresholdNonRecoverable

Fault Code: F0385

Message

Power supply [id] in chassis [id] temperature: [thermal]Power supply [id] in fabric interconnect [id] temperature: [thermal]Power supply [id] in server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a PSU module has been out of operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the PSU module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the PSU modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty PSU modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 385
mibFaultName: fltEquipmentPsuThermalThresholdNonRecoverable
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuVoltageThresholdNonCritical

Fault Code: F0387

Message

Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]

Explanation

This fault occurs when the PSU voltage is out of normal operating range, but hasn’t reached to a critical stage yet. Normally the PSU will recover itself from this situation.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor the PSU for further degradation.

Step 2blank.gif Remove and reseat the PSU.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: voltage-problem
mibFaultCode: 387
mibFaultName: fltEquipmentPsuVoltageThresholdNonCritical
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuVoltageThresholdCritical

Fault Code: F0389

Message

Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]

Explanation

This fault occurs when the PSU voltage has exceeded the specified hardware voltage rating.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove and reseat the PSU.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: voltage-problem
mibFaultCode: 389
mibFaultName: fltEquipmentPsuVoltageThresholdCritical
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuVoltageThresholdNonRecoverable

Fault Code: F0391

Message

Power supply [id] in chassis [id] voltage: [voltage]Power supply [id] in fabric interconnect [id] voltage: [voltage]Power supply [id] in fex [id] voltage: [voltage]Power supply [id] in server [id] voltage: [voltage]

Explanation

This fault occurs when the PSU voltage has exceeded the specified hardware voltage rating and PSU hardware may have been damaged as a result or may be at risk of being damaged.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove and reseat the PSU.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: voltage-problem
mibFaultCode: 391
mibFaultName: fltEquipmentPsuVoltageThresholdNonRecoverable
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuPerfThresholdNonCritical

Fault Code: F0392

Message

Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]

Explanation

This fault is raised as a warning if the current output of the PSU in a chassis, fabric interconnect, or rack server does not match the desired output value.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor the PSU status.

Step 2blank.gif If possible, remove and reseat the PSU.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file for the chassis and Cisco FPR Manager, and contact Cisco TAC.

Fault Details

Severity: minor
Cause: performance-problem
mibFaultCode: 392
mibFaultName: fltEquipmentPsuPerfThresholdNonCritical
moClass: equipment:Psu
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuPerfThresholdCritical

Fault Code: F0393

Message

Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]

Explanation

This fault occurs if the current output of the PSU in a chassis, fabric interconnect, or rack server is far below or above the desired output value.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor the PSU status.

Step 2blank.gif Plan to replace the PSU as soon as possible.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file for the chassis and Cisco FPR Manager, and contact Cisco TAC.

Fault Details

Severity: major
Cause: performance-problem
mibFaultCode: 393
mibFaultName: fltEquipmentPsuPerfThresholdCritical
moClass: equipment:Psu
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuPerfThresholdNonRecoverable

Fault Code: F0394

Message

Power supply [id] in chassis [id] output power: [perf]Power supply [id] in fabric interconnect [id] output power: [perf]Power supply [id] in server [id] output power: [perf]

Explanation

This fault occurs if the current output of the PSU in a chassis, fabric interconnect, or rack server is far above or below the non-recoverable threshold value.

Recommended Action

If you see this fault, plan to replace the PSU as soon as possible.

Fault Details

Severity: critical
Cause: performance-problem
mibFaultCode: 394
mibFaultName: fltEquipmentPsuPerfThresholdNonRecoverable
moClass: equipment:Psu
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentFanPerfThresholdNonCritical

Fault Code: F0395

Message

Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]

Explanation

This fault occurs when the fan speed reading from the fan controller does not match the desired fan speed and is outside of the normal operating range. This can indicate a problem with a fan or with the reading from the fan controller.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor the fan status.

Step 2blank.gif If the problem persists for a long period of time or if other fans do not show the same problem, reseat the fan.

Step 3blank.gif Replace the fan module.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: performance-problem
mibFaultCode: 395
mibFaultName: fltEquipmentFanPerfThresholdNonCritical
moClass: equipment:Fan
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]

fltEquipmentFanPerfThresholdCritical

Fault Code: F0396

Message

Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]

Explanation

This fault occurs when the fan speed read from the fan controller does not match the desired fan speed and has exceeded the critical threshold and is in risk of failure. This can indicate a problem with a fan or with the reading from the fan controller.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor the fan status.

Step 2blank.gif If the problem persists for a long period of time or if other fans do not show the same problem, reseat the fan.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file for the chassis and contact Cisco TAC.

Fault Details

Severity: info
Cause: performance-problem
mibFaultCode: 396
mibFaultName: fltEquipmentFanPerfThresholdCritical
moClass: equipment:Fan
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]

fltEquipmentFanPerfThresholdNonRecoverable

Fault Code: F0397

Message

Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]

Explanation

This fault occurs when the fan speed read from the fan controller has far exceeded the desired fan speed. It frequently indicates that the fan has failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Replace the fan.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: performance-problem
mibFaultCode: 397
mibFaultName: fltEquipmentFanPerfThresholdNonRecoverable
moClass: equipment:Fan
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]

fltEquipmentIOCardFirmwareUpgrade

Fault Code: F0398

Message

Chassis controller in IOM [chassisId]/[id] ([switchId]) firmware upgrade problem: [upgradeStatus]

Explanation

This fault typically occurs when an IOM upgrade fails.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif On the FSM tab for the IOM, verify whether FSM for the upgrade completed successfully or failed.

Step 2blank.gif If the FSM failed, review the error message in the FSM.

Step 3blank.gif If the error message is self explanatory, verify the physical connectivity. For example, an error message could be No Connection to Endpoint or Link Down.

Step 4blank.gif If the above action did not resolve the issue and the fault persists, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: firmware-upgrade-problem
mibFaultCode: 398
mibFaultName: fltEquipmentIOCardFirmwareUpgrade
moClass: equipment:IOCard
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentChassisUnsupportedConnectivity

Fault Code: F0399

Message

Current connectivity for chassis [id] does not match discovery policy: [configState]

Explanation

This fault typically occurs when the current connectivity for a chassis does not match the configuration in the chassis discovery policy.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the correct number of links are configured in the chassis discovery policy.

Step 2blank.gif Check the state of the I/O module links.

Step 3blank.gif Reacknowledge the chassis.

Step 4blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: unsupported-connectivity-configuration
mibFaultCode: 399
mibFaultName: fltEquipmentChassisUnsupportedConnectivity
moClass: equipment:Chassis
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltEquipmentChassisUnacknowledged

Fault Code: F0400

Message

Chassis [id] connectivity configuration: [configState]

Explanation

This fault typically occurs when or more of the I/O module links from the chassis are unacknowledged.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the state of the I/O module links.

Step 2blank.gif Reacknowledge the chassis.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-unacknowledged
mibFaultCode: 400
mibFaultName: fltEquipmentChassisUnacknowledged
moClass: equipment:Chassis
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltEquipmentIOCardUnsupportedConnectivity

Fault Code: F0401

Message

IOM [chassisId]/[id] ([switchId]) current connectivity does not match discovery policy or connectivity is unsupported: [configState]

Explanation

This fault typically occurs when the current connectivity for an I/O module does not match the configuration in the chassis discovery policy.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the correct number of links are configured in the chassis discovery policy.

Step 2blank.gif Check the state of the I/O module links.

Step 3blank.gif Note that atleast 2 links are required to be connected between FEX and 61xx Fabric Interconnect

Step 4blank.gif Reacknowledge the chassis.

Step 5blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: unsupported-connectivity-configuration
mibFaultCode: 401
mibFaultName: fltEquipmentIOCardUnsupportedConnectivity
moClass: equipment:IOCard
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentIOCardUnacknowledged

Fault Code: F0402

Message

IOM [chassisId]/[id] ([switchId]) connectivity configuration: [configState]

Explanation

This fault typically occurs when an I/O module is unacknowledged.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the state of the I/O module links.

Step 2blank.gif Reacknowledge the chassis.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-unacknowledged
mibFaultCode: 402
mibFaultName: fltEquipmentIOCardUnacknowledged
moClass: equipment:IOCard
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentIOCardPeerDisconnected

Fault Code: F0403

Message

IOM [chassisId]/[id] ([switchId]) peer connectivity: [peerCommStatus]

Explanation

This fault typically occurs when an I/O module is unable to communicate with its peer I/O module.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.

Step 2blank.gif If the fault does not clear after a few minutes, remove and reinsert the I/O module.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-disconnected
mibFaultCode: 403
mibFaultName: fltEquipmentIOCardPeerDisconnected
moClass: equipment:IOCard
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentChassisIdentity

Fault Code: F0404

Message

Chassis [id] has a mismatch between FRU identity reported by Fabric/IOM vs. FRU identity reported by CMC

Explanation

This fault typically occurs when the FRU information for an I/O module is corrupted or malformed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fru-problem
mibFaultCode: 404
mibFaultName: fltEquipmentChassisIdentity
moClass: equipment:Chassis
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltEquipmentIOCardIdentity

Fault Code: F0405

Message

[side] IOM [chassisId]/[id] ([switchId]) has a malformed FRU

Explanation

This fault typically occurs when the FRU information for an I/O module is corrupted or malformed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fru-problem
mibFaultCode: 405
mibFaultName: fltEquipmentIOCardIdentity
moClass: equipment:IOCard
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentFanModuleIdentity

Fault Code: F0406

Message

Fan Module [tray]-[id] in chassis [id] has a malformed FRUFan Module [tray]-[id] in server [id] has a malformed FRUFan Module [tray]-[id] in fabric interconnect [id] has a malformed FRU

Explanation

This fault typically occurs when the FRU information for a fan module is corrupted or malformed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fru-problem
mibFaultCode: 406
mibFaultName: fltEquipmentFanModuleIdentity
moClass: equipment:FanModule
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]

fltEquipmentPsuIdentity

Fault Code: F0407

Message

Power supply [id] on chassis [id] has a malformed FRUPower supply [id] on server [id] has a malformed FRU

Explanation

This fault typically occurs when the FRU information for a power supply unit is corrupted or malformed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fru-problem
mibFaultCode: 407
mibFaultName: fltEquipmentPsuIdentity
moClass: equipment:Psu
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentChassisPowerProblem

Fault Code: F0408

Message

Power state on chassis [id] is [power]

Explanation

This fault typically occurs when the chassis fails to meet the minimal power requirements defined in the power policy or when one or more power supplies have failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif In Cisco FPR Manager, verify that all PSUs for the chassis are functional.

Step 2blank.gif Verify that all PSUs are seated properly within the chassis and are powered on.

Step 3blank.gif Physically unplug and replug the power cord into the chassis.

Step 4blank.gif If all PSUs are operating at maximum capacity, either add more PSUs to the chassis or redefine the power policy in Cisco FPR Manager.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-problem
mibFaultCode: 408
mibFaultName: fltEquipmentChassisPowerProblem
moClass: equipment:Chassis
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltEquipmentChassisThermalThresholdCritical

Fault Code: F0409

Message

Thermal condition on chassis [id]. [thermalStateQualifier]

Explanation

This fault occurs under the following conditions:


Step 1blank.gif If a component within a chassis is operating outside the safe thermal operating range.

Step 2blank.gif If the chassis controller in the supervisor is unable to determine the thermal condition of a blade server, the show tech-support file for the chassis provides a more detailed report of the most severe thermal conditions currently applicable for that chassis.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the temperature readings for the blade servers and supervisor and ensure they are within the recommended thermal safe operating range.

Step 2blank.gif If the fault reports a "Thermal Sensor threshold crossing in blade" error for one or more blade servers, check if DIMM or processor temperature related faults have been raised against that blade.

Step 3blank.gif If the fault reports a "Thermal Sensor threshold crossing in supervisor" error for supervisor, check if thermal faults have been raised against that supervisor. Those faults include details of the thermal condition.

Step 4blank.gif If the fault reports a "Missing or Faulty Fan" error, check on the status of that fan. If it needs replacement, create a show tech-support file for the chassis and contact Cisco TAC.

Step 5blank.gif If the fault reports a "No connectivity between supervisor and blade" or "Thermal Sensor readings unavailable from blade" error, check if that blade server is operational and whether any faults have been raised against that blade server. In this situation, the chassis controller may go into a fail-safe operating mode and the fan speeds may increase as a precautionary measure.

Step 6blank.gif If the above actions did not resolve the issue and the condition persists, create a show tech-support file for Cisco FPR Manager and the chassis and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 409
mibFaultName: fltEquipmentChassisThermalThresholdCritical
moClass: equipment:Chassis
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltEquipmentChassisThermalThresholdNonRecoverable

Fault Code: F0411

Message

Thermal condition on chassis [id]. [thermalStateQualifier]

Explanation

FPRM raises this fault under the following conditions:


Step 1blank.gif If a component within a chassis is operating outside the safe thermal operating range.

Step 2blank.gif If the chassis controller in the supervisor is unable to determine the thermal condition of a blade server, the show tech-support file for the chassis provides a more detailed report of the most severe thermal conditions currently applicable for that chassis.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the temperature readings for the blade servers and supervisor and ensure they are within the recommended thermal safe operating range.

Step 2blank.gif If the fault reports a "Thermal Sensor threshold crossing in blade" error for one or more blade servers, check if DIMM or processor temperature related faults have been raised against that blade.

Step 3blank.gif If the fault reports a "Thermal Sensor threshold crossing in supervisor" error for supervisor, check if thermal faults have been raised against that supervisor. Those faults include details of the thermal condition.

Step 4blank.gif If the fault reports a "Missing or Faulty Fan" error, check on the status of that fan. If it needs replacement, create a show tech-support file for the chassis and contact Cisco TAC.

Step 5blank.gif If the fault reports a "No connectivity between supervisor and blade" or "Thermal Sensor readings unavailable from blade" error, check if that blade server is operational and whether any faults have been raised against that blade server. In this situation, the chassis controller may go into a fail-safe operating mode and the fan speeds may increase as a precautionary measure.

Step 6blank.gif If the above actions did not resolve the issue and the condition persists, create a show tech-support file for Cisco FPR Manager and the chassis and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 411
mibFaultName: fltEquipmentChassisThermalThresholdNonRecoverable
moClass: equipment:Chassis
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltComputeBoardCmosVoltageThresholdCritical

Fault Code: F0424

Message

Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]

Explanation

This fault is raised when the CMOS battery voltage has dropped to lower than the normal operating range. This could impact the clock and other CMOS settings.

Recommended Action

If you see this fault, replace the battery.

Fault Details

Severity: major
Cause: voltage-problem
mibFaultCode: 424
mibFaultName: fltComputeBoardCmosVoltageThresholdCritical
moClass: compute:Board
Type: environmental
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board

fltComputeBoardCmosVoltageThresholdNonRecoverable

Fault Code: F0425

Message

Possible loss of CMOS settings: CMOS battery voltage on server [chassisId]/[slotId] is [cmosVoltage]Possible loss of CMOS settings: CMOS battery voltage on server [id] is [cmosVoltage]

Explanation

This fault is raised when the CMOS battery voltage has dropped quite low and is unlikely to recover. This impacts the clock and other CMOS settings.

Recommended Action

If you see this fault, replace the battery.

Fault Details

Severity: major
Cause: voltage-problem
mibFaultCode: 425
mibFaultName: fltComputeBoardCmosVoltageThresholdNonRecoverable
moClass: compute:Board
Type: environmental
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board

fltMgmtEntityElection-failure

Fault Code: F0428

Message

Fabric Interconnect [id], election of primary managemt instance has failed

Explanation

This fault occurs in an unlikely event that the fabric interconnects in a cluster configuration could not reach an agreement for selecting the primary fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the initial setup configuration is correct on both fabric interconnects.

Step 2blank.gif Verify that the L1 and L2 links are properly connected between the fabric interconnects.

Step 3blank.gif In the Cisco FPR Manager CLI, run the cluster force primary local-mgmt command on one fabric interconnect.

Step 4blank.gif Reboot the fabric interconnects.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: election-failure
mibFaultCode: 428
mibFaultName: fltMgmtEntityElectionFailure
moClass: mgmt:Entity
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltMgmtEntityHa-not-ready

Fault Code: F0429

Message

Fabric Interconnect [id], HA functionality not ready

Explanation

This fault occurs if Cisco FPR Manager cannot discover or communicate with one or more chassis or rack servers to write the HA Cluster state. This impacts the full HA functionality of the fabric interconnect cluster.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the initial setup configuration is correct on both fabric interconnects.

Step 2blank.gif Verify that the L1 and L2 links are properly connected between the fabric interconnects.

Step 3blank.gif Verify that the IOMs and/or FEXes are reachable and the server ports are enabled and operationally up.

Step 4blank.gif Verify that the chassis and/or rack servers are powered up and reachable

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: ha-not-ready
mibFaultCode: 429
mibFaultName: fltMgmtEntityHaNotReady
moClass: mgmt:Entity
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltMgmtEntityVersion-incompatible

Fault Code: F0430

Message

Fabric Interconnect [id], management services, incompatible versions

Explanation

This fault occurs if the Cisco FPR Manager software on the subordinate fabric interconnect is not the same release as that of the primary fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Upgrade the Cisco FPR Manager software on the subordinate fabric interconnect to the same release as the primary fabric interconnect and verify that both fabric interconnects are running the same release of Cisco FPR Manager.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: version-incompatible
mibFaultCode: 430
mibFaultName: fltMgmtEntityVersionIncompatible
moClass: mgmt:Entity
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltEquipmentFanMissing

Fault Code: F0434

Message

Fan [id] in fabric interconnect [id] presence: [presence]Fan [id] in fex [id] presence: [presence]Fan [id] in Fan Module [tray]-[id] under server [id] presence: [presence]

Explanation

This fault occurs in the unlikely event that a fan in a fan module cannot be detected.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Insert/reinsert the fan module in the slot that is reporting the issue.

Step 2blank.gif Replace the fan module with a different fan module, if available.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-missing
mibFaultCode: 434
mibFaultName: fltEquipmentFanMissing
moClass: equipment:Fan
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]

fltEquipmentIOCardAutoUpgradingFirmware

Fault Code: F0435

Message

IOM [chassisId]/[id] ([switchId]) is auto upgrading firmware

Explanation

This fault typically occurs when an I/O module is auto upgrading. Auto-upgrade occurs when the firmware version on the IOM is incompatible with the firmware version on the fabric interconnect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the IOM and fabric interconnects are not running the same firmware version, wait for the auto-upgrade to complete.

Step 2blank.gif When the IOM upgrade is completed, verify that Cisco FPR Manager has cleared this fault.

Step 3blank.gif If you see this fault after the IOM overall status changes to operable, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: auto-firmware-upgrade
mibFaultCode: 435
mibFaultName: fltEquipmentIOCardAutoUpgradingFirmware
moClass: equipment:IOCard
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltFirmwarePackItemImageMissing

Fault Code: F0436

Message

[type] image with vendor [hwVendor], model [hwModel] and version [version] is deleted

Explanation

This fault typically occurs when the image to which a firmware package item refers is missing.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif In Cisco FPR Manager GUI, navigate to the Firmware Management Images tab and determine whether the missing image is available or not.

Step 2blank.gif If the image is present, click on it to verify the model and vendor.

Step 3blank.gif If the image for the required model and vendor is not present, download that image or bundle from the Cisco.com website.

Step 4blank.gif If the image is present and the fault persists, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: image-deleted
mibFaultCode: 436
mibFaultName: fltFirmwarePackItemImageMissing
moClass: firmware:PackItem
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/fw-catalog-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-host-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-infra-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-mgmt-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/fw-platform-pack-[name]/pack-image-[hwVendor]|[hwModel]|[type]
Affected MO: org-[name]/pack-image-[hwVendor]|[hwModel]|[type]

fltEtherSwitchIntFIoSatellite-wiring-numbers-unexpected

Fault Code: F0440

Message

Chassis discovery policy conflict: Link IOM [chassisId]/[slotId]/[portId] to fabric interconnect [switchId]:[peerSlotId]/[peerPortId] not configured

Explanation

The configuration of the chassis discovery policy conflicts with the physical IOM uplinks. Cisco FPR Manager raises this fault when the chassis discovery policy is configured for more links than are physically cabled between the IOM uplinks on the chassis and the fabric interconnect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Ensure that you cable at least the same number of IOM uplinks as are configured in the chassis discovery policy, and that you configure the corresponding server ports on the fabric interconnect.

Step 2blank.gif Reacknowledge the chassis.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: unexpected-number-of-links
mibFaultCode: 440
mibFaultName: fltEtherSwitchIntFIoSatelliteWiringNumbersUnexpected
moClass: ether:SwitchIntFIo
Type: connectivity
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltMgmtEntityManagement-services-failure

Fault Code: F0451

Message

Fabric Interconnect [id], management services have failed

Explanation

This fault occurs in an unlikely event that management services fail on a fabric interconnect. This impacts the full HA functionality of the fabric interconnect cluster.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the initial setup configuration is correct on both fabric interconnects.

Step 2blank.gif Verify that the L1 and L2 links are properly connected between the fabric interconnects.

Step 3blank.gif Reboot the fabric interconnects.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: management-services-failure
mibFaultCode: 451
mibFaultName: fltMgmtEntityManagementServicesFailure
moClass: mgmt:Entity
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltMgmtEntityManagement-services-unresponsive

Fault Code: F0452

Message

Fabric Interconnect [id], management services are unresponsive

Explanation

This fault occurs when management services on a fabric interconnect are unresponsive. This impacts the full HA functionality of the fabric interconnect cluster.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the initial setup configuration is correct on both fabric interconnects.

Step 2blank.gif Verify that the L1 and L2 links are properly connected between the fabric interconnects.

Step 3blank.gif Reboot the fabric interconnects.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: management-services-unresponsive
mibFaultCode: 452
mibFaultName: fltMgmtEntityManagementServicesUnresponsive
moClass: mgmt:Entity
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltEquipmentChassisInoperable

Fault Code: F0456

Message

Chassis [id] operability: [operability]

Explanation

This fault typically occurs for one of the following reasons:

  • The fabric interconnect cannot communicate with a chassis. For a cluster configuration, this fault means that neither fabric interconnect can communicate with the chassis.
  • The chassis has an invalid FRU.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif In Cisco FPR Manager, reacknowledge the chassis that raised the fault.

Step 2blank.gif Physically unplug and replug the power cord into the chassis.

Step 3blank.gif Verify that the I/O modules are functional.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-inoperable
mibFaultCode: 456
mibFaultName: fltEquipmentChassisInoperable
moClass: equipment:Chassis
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltEtherServerIntFIoHardware-failure

Fault Code: F0458

Message

IOM [transport] interface [portId] on chassis [id] oper state: [operState], reason: [stateQual]Fabric Interconnect [transport] interface [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]IOM [transport] interface [portId] on fex [id] oper state: [operState], reason: [stateQual]

Explanation

This fault is raised on the IOM/FEX backplane ports when Cisco FPR Manager detects a hardware failure.

Recommended Action

If you see this fault, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: interface-failed
mibFaultCode: 458
mibFaultName: fltEtherServerIntFIoHardwareFailure
moClass: ether:ServerIntFIo
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/rack-unit-[id]/diag/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltDcxVcMgmt-vif-down

Fault Code: F0459

Message

IOM [chassisId] / [slotId] ([switchId]) management VIF [id] down, reason [stateQual]

Explanation

This fault occurs when the transport VIF for an I/O module is down. Cisco FPR Manager raises this fault when a fabric interconnect reports the connectivity state on virtual interface as one of the following:

  • Down
  • Errored
  • Unavailable

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the chassis discovery has gone through successfully. Check the states on all communicating ports from end to end.

Step 2blank.gif If connectivity seems correct, decommission and recommission the chassis.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: cmc-vif-down
mibFaultCode: 459
mibFaultName: fltDcxVcMgmtVifDown
moClass: dcx:Vc
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]

fltSysdebugMEpLogMEpLogLog

Fault Code: F0460

Message

Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]

Explanation

This fault typically occurs because Cisco FPR Manager has detected that the system event log (SEL) on the server is approaching full capacity. The available capacity in the log is low. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.

Recommended Action

If you see this fault, you can clear the SEL in Cisco FPR Manager if desired.

Fault Details

Severity: info
Cause: log-capacity
mibFaultCode: 460
mibFaultName: fltSysdebugMEpLogMEpLogLog
moClass: sysdebug:MEpLog
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]

fltSysdebugMEpLogMEpLogVeryLow

Fault Code: F0461

Message

Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]

Explanation

This fault typically occurs because Cisco FPR Manager has detected that the system event log (SEL) on the server is almost full. The available capacity in the log is very low. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.

Recommended Action

If you see this fault, you can clear the SEL in Cisco FPR Manager if desired.

Fault Details

Severity: info
Cause: log-capacity
mibFaultCode: 461
mibFaultName: fltSysdebugMEpLogMEpLogVeryLow
moClass: sysdebug:MEpLog
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]

fltSysdebugMEpLogMEpLogFull

Fault Code: F0462

Message

Log capacity on [side] IOM [chassisId]/[id] is [capacity]Log capacity on Management Controller on server [chassisId]/[slotId] is [capacity]Log capacity on Management Controller on server [id] is [capacity]

Explanation

This fault typically occurs because Cisco FPR Manager could not transfer the SEL file to the location specified in the SEL policy. This is an info-level fault and can be ignored if you do not want to clear the SEL at this time.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify the configuration of the SEL policy to ensure that the location, user, and password provided are correct.

Step 2blank.gif If you do want to transfer and clear the SEL and the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: log-capacity
mibFaultCode: 462
mibFaultName: fltSysdebugMEpLogMEpLogFull
moClass: sysdebug:MEpLog
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]

fltComputePoolEmpty

Fault Code: F0463

Message

server pool [name] is empty

Explanation

This fault typically occurs when the selected server pool does not contain any servers.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify the qualifier settings in the server pool policy qualifications. If the policy was modified after the server was discovered, reacknowledge the server.

Step 2blank.gif Manually associate the service profile with a server.

Step 3blank.gif If the server pool is not used, ignore the fault.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: empty-pool
mibFaultCode: 463
mibFaultName: fltComputePoolEmpty
moClass: compute:Pool
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/compute-pool-[name]

fltUuidpoolPoolEmpty

Fault Code: F0464

Message

UUID suffix pool [name] is empty

Explanation

This fault typically occurs when a UUID suffix pool does not contain any UUID suffixes.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the pool is in use, add a block of UUID suffixes to the pool.

Step 2blank.gif If the pool is not in use, ignore the fault.

Fault Details

Severity: minor
Cause: empty-pool
mibFaultCode: 464
mibFaultName: fltUuidpoolPoolEmpty
moClass: uuidpool:Pool
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/uuid-pool-[name]

fltIppoolPoolEmpty

Fault Code: F0465

Message

IP pool [name] is empty

Explanation

This fault typically occurs when an IP address pool does not contain any IP addresses.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the pool is in use, add a block of IP addresses to the pool.

Step 2blank.gif If the pool is not in use, ignore the fault.

Fault Details

Severity: minor
Cause: empty-pool
mibFaultCode: 465
mibFaultName: fltIppoolPoolEmpty
moClass: ippool:Pool
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/network-sets/ip-pool-[name]
Affected MO: org-[name]/ip-pool-[name]

fltMacpoolPoolEmpty

Fault Code: F0466

Message

MAC pool [name] is empty

Explanation

This fault typically occurs when a MAC address pool does not contain any MAC addresses.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the pool is in use, add a block of MAC addresses to the pool.

Step 2blank.gif If the pool is not in use, ignore the fault.

Fault Details

Severity: minor
Cause: empty-pool
mibFaultCode: 466
mibFaultName: fltMacpoolPoolEmpty
moClass: macpool:Pool
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/mac-pool-[name]

fltFirmwareUpdatableImageUnusable

Fault Code: F0470

Message

backup image is unusable. reason: [operStateQual]

Explanation

This fault typically occurs when the backup firmware image on an endpoint is unusable.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the fault and the error message on the FSM tab for the endpoint to determine why the firmware image is unusable.

Step 2blank.gif If the firmware image is bad or corrupted, download another copy from the Cisco website and update the backup version on the endpoint with the new image.

Step 3blank.gif If the image is present and the fault persists, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: image-unusable
mibFaultCode: 470
mibFaultName: fltFirmwareUpdatableImageUnusable
moClass: firmware:Updatable
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-updatable
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-updatable
Affected MO: sys/chassis-[id]/fpga/fw-updatable
Affected MO: sys/chassis-[id]/rommon/fw-updatable
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/mgmt/fw-updatable
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-updatable
Affected MO: sys/mgmt/fw-updatable
Affected MO: sys/os-ctrl/fw-updatable
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/mgmt/fw-updatable
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-updatable
Affected MO: sys/switch-[id]/mgmt/fw-updatable

fltFirmwareBootUnitCantBoot

Fault Code: F0471

Message

unable to boot the startup image. End point booted with backup image

Explanation

This fault typically occurs when the startup firmware image on an endpoint is corrupted or invalid, and the endpoint cannot boot from that image.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the fault and the error message on the FSM tab for the endpoint to determine why the firmware image is unusable. The error message usually includes an explanation for why the endpoint could not boot from the startup image, such as Bad-Image or Checksum Failed.

Step 2blank.gif If the firmware image is bad or corrupted, download another copy from the Cisco website and update the startup version on the endpoint with the new image.

Step 3blank.gif If the fault persists, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: image-cannot-boot
mibFaultCode: 471
mibFaultName: fltFirmwareBootUnitCantBoot
moClass: firmware:BootUnit
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/fpga/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/rommon/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]

fltFcpoolInitiatorsEmpty

Fault Code: F0476

Message

FC pool [purpose] [name] is empty

Explanation

This fault typically occurs when a WWN pool does not contain any WWNs.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the pool is in use, add a block of WWNs to the pool.

Step 2blank.gif If the pool is not in use, ignore the fault.

Fault Details

Severity: minor
Cause: empty-pool
mibFaultCode: 476
mibFaultName: fltFcpoolInitiatorsEmpty
moClass: fcpool:Initiators
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/wwn-pool-[name]

fltEquipmentIOCardInaccessible

Fault Code: F0478

Message

[side] IOM [chassisId]/[id] ([switchId]) is inaccessible

Explanation

This fault typically occurs because an I/O module has lost its connection to the fabric interconnects. In a cluster configuration, the chassis fails over to the other I/O module. For a standalone configuration, the chassis associated with the I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the I/O module.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Wait a few minutes to see if the fault clears. This is typically a temporary issue, and can occur after a firmware upgrade.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-inaccessible
mibFaultCode: 478
mibFaultName: fltEquipmentIOCardInaccessible
moClass: equipment:IOCard
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltDcxVIfLinkState

Fault Code: F0479

Message

Virtual interface [id] link state is down

Explanation

This fault occurs when Cisco FPR cannot send or receive data through an uplink port.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reenable the uplink port that failed.

Step 2blank.gif Check the associated port to ensure it is in up state.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: vif-down
mibFaultCode: 479
mibFaultName: fltDcxVIfLinkState
moClass: dcx:VIf
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-service-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fcoe/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/vif-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-service-eth-[id]/vif-[id]

fltEquipmentFanModuleDegraded

Fault Code: F0480

Message

Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]

Explanation

This fault occurs when a fan module is not operational.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the fan module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the fan module has adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows for the fan module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: equipment-degraded
mibFaultCode: 480
mibFaultName: fltEquipmentFanModuleDegraded
moClass: equipment:FanModule
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]

fltEquipmentIOCardPost-failure

Fault Code: F0481

Message

[side] IOM [chassisId]/[id] ([switchId]) POST failure

Explanation

This fault typically occurs when an I/O module encounters errors during the Power On Self Test (POST). The impact of this fault varies according to the errors that were encountered during POST.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the POST results for the I/O module. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the I/O module. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the I/O module.

Step 2blank.gif If the POST results indicate FRU error, check if FPR manager has raised fault for the FRU and follow recommended action for the fault.

Step 3blank.gif Otherwise, reboot the I/O module.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-problem
mibFaultCode: 481
mibFaultName: fltEquipmentIOCardPostFailure
moClass: equipment:IOCard
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentFanPerfThresholdLowerNonRecoverable

Fault Code: F0484

Message

Fan [id] in Fan Module [tray]-[id] under chassis [id] speed: [perf]Fan [id] in fabric interconnect [id] speed: [perf]Fan [id] in Fan Module [tray]-[id] under server [id] speed: [perf]

Explanation

This fault occurs when the fan speed reading from the fan controller is far below the desired fan speed, and the fan has likely failed.

Recommended Action

If you see this fault, create a detailed show tech-support file for the chassis and replace the fan module. If necessary, contact Cisco TAC.

Fault Details

Severity: critical
Cause: performance-problem
mibFaultCode: 484
mibFaultName: fltEquipmentFanPerfThresholdLowerNonRecoverable
moClass: equipment:Fan
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/fex-[id]/fan-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/fan-[id]

fltComputePhysicalPost-failure

Fault Code: F0517

Message

Server [id] POST or diagnostic failureServer [chassisId]/[slotId] POST or diagnostic failure

Explanation

This fault typically occurs when the server has encountered a diagnostic failure or an error during POST.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the POST results for the server. In Cisco FPR Manager GUI, you can access the POST results from the General tab for the server. In Cisco FPR Manager CLI, you can access the POST results through the show post command under the scope for the server.

Step 2blank.gif Reboot the server.

Step 3blank.gif If the above actions did not resolve the issue, execute the show tech-support command and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: equipment-problem
mibFaultCode: 517
mibFaultName: fltComputePhysicalPostFailure
moClass: compute:Physical
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltEquipmentPsuOffline

Fault Code: F0528

Message

Power supply [id] in chassis [id] power: [power]Power supply [id] in fabric interconnect [id] power: [power]Power supply [id] in fex [id] power: [power]Power supply [id] in server [id] power: [power]

Explanation

This fault typically occurs when Cisco FPR Manager detects that a power supply unit in a chassis, fabric interconnect, or FEX is offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the power cord is properly connected to the PSU and the power source.

Step 2blank.gif Verify that the power source is 220 volts.

Step 3blank.gif Verify that the PSU is properly installed in the chassis or fabric interconnect.

Step 4blank.gif Remove the PSU and reinstall it.

Step 5blank.gif Replace the PSU.

Step 6blank.gif If the above actions did not resolve the issue, note down the type of PSU, execute the show tech-support command, and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: equipment-offline
mibFaultCode: 528
mibFaultName: fltEquipmentPsuOffline
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltStorageRaidBatteryInoperable

Fault Code: F0531

Message

RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

This fault occurs when the RAID backup unit is not operational.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the backup unit is a battery, replace the battery.

Step 2blank.gif If the backup unit is a supercapacitor type and the supercapacitor is missing, verify its presence and supply if missing.

Step 3blank.gif If the backup unit is a supercapacitor type and the TFM is missing, verify its presence and supply if missing.

Step 4blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 531
mibFaultName: fltStorageRaidBatteryInoperable
moClass: storage:RaidBattery
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery

fltSysdebugMEpLogTransferError

Fault Code: F0532

Message

Server [chassisId]/[slotId] [type] transfer failed: [operState]Server [id] [type] transfer failed: [operState]

Explanation

This fault occurs when the transfer of a managed endpoint log file, such as the SEL, fails.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the fault is related to the SEL, verify the connectivity to the CIMC on the server.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: file-transfer-failed
mibFaultCode: 532
mibFaultName: fltSysdebugMEpLogTransferError
moClass: sysdebug:MEpLog
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/mgmt/log-[type]-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/log-[type]-[id]
Affected MO: sys/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/log-[type]-[id]
Affected MO: sys/rack-unit-[id]/mgmt/log-[type]-[id]
Affected MO: sys/switch-[id]/mgmt/log-[type]-[id]

fltComputeRtcBatteryInoperable

Fault Code: F0533

Message

RTC Battery on server [chassisId]/[slotId] operability: [operability]

Explanation

This fault is raised when the CMOS battery voltage is below the normal operating range. This impacts the system clock.

Recommended Action

If you see this fault, replace the CMOS battery.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 533
mibFaultName: fltComputeRtcBatteryInoperable
moClass: compute:RtcBattery
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/rtc-battery
Affected MO: sys/rack-unit-[id]/board/rtc-battery

fltMemoryBufferUnitThermalThresholdNonCritical

Fault Code: F0535

Message

Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a memory buffer unit on a blade or rack server exceeds a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: thermal-problem
mibFaultCode: 535
mibFaultName: fltMemoryBufferUnitThermalThresholdNonCritical
moClass: memory:BufferUnit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]

fltMemoryBufferUnitThermalThresholdCritical

Fault Code: F0536

Message

Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a memory buffer unit on a blade or rack server exceeds a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 536
mibFaultName: fltMemoryBufferUnitThermalThresholdCritical
moClass: memory:BufferUnit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]

fltMemoryBufferUnitThermalThresholdNonRecoverable

Fault Code: F0537

Message

Buffer Unit [id] on server [chassisId]/[slotId] temperature: [thermal]Buffer Unit [id] on server [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a memory buffer unit on a blade or rack server has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 537
mibFaultName: fltMemoryBufferUnitThermalThresholdNonRecoverable
moClass: memory:BufferUnit
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/sensor-unit-[id]
Affected MO: sys/rack-unit-[id]/board/sensor-unit-[id]

fltComputeIOHubThermalNonCritical

Fault Code: F0538

Message

IO Hub on server [chassisId]/[slotId] temperature: [thermal]

Explanation

This fault is raised when the IO controller temperature is outside the upper or lower non-critical threshold.

Recommended Action

If you see this fault, monitor other environmental events related to this server and ensure the temperature ranges are within recommended ranges.

Fault Details

Severity: minor
Cause: thermal-problem
mibFaultCode: 538
mibFaultName: fltComputeIOHubThermalNonCritical
moClass: compute:IOHub
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub

fltComputeIOHubThermalThresholdCritical

Fault Code: F0539

Message

IO Hub on server [chassisId]/[slotId] temperature: [thermal]

Explanation

This fault is raised when the IO controller temperature is outside the upper or lower critical threshold.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Monitor other environmental events related to the server and ensure the temperature ranges are within recommended ranges.

Step 2blank.gif Consider turning off the server for a while if possible.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 539
mibFaultName: fltComputeIOHubThermalThresholdCritical
moClass: compute:IOHub
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub

fltComputeIOHubThermalThresholdNonRecoverable

Fault Code: F0540

Message

IO Hub on server [chassisId]/[slotId] temperature: [thermal]

Explanation

This fault is raised when the IO controller temperature is outside the recoverable range of operation.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Shutdown the server immediately.

Step 2blank.gif Create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 540
mibFaultName: fltComputeIOHubThermalThresholdNonRecoverable
moClass: compute:IOHub
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/iohub
Affected MO: sys/rack-unit-[id]/board/iohub

fltEquipmentChassisIdentity-unestablishable

Fault Code: F0543

Message

Chassis [id] has an invalid FRU

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported chassis. For example, the model, vendor, or revision is not recognized.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, execute the show tech-support command and contact Cisco technical support.

Fault Details

Severity: major
Cause: identity-unestablishable
mibFaultCode: 543
mibFaultName: fltEquipmentChassisIdentityUnestablishable
moClass: equipment:Chassis
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltSwVlanPortNsResourceStatus

Fault Code: F0549

Message

Vlan-Port Resource exceeded

Explanation

This fault occurs when the total number of configured VLANs in the Cisco FPR instance has exceeded the allowed maximum number of configured VLANs on the fabric interconnect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif In the Cisco FPR Manager CLI or Cisco FPR Manager GUI, check the port VLAN count to determine by how many VLANs the system is over the maximum.

Step 2blank.gif Reduce the VLAN port count in one of the following ways:

–blank.gif Delete VLANs configured on the LAN cloud.

–blank.gif Delete VLANs configured on vNICs.

–blank.gif Unconfigure one or more vNICs.

–blank.gif Unconfigure one or more uplink Ethernet ports on the fabric interconnect.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: limit-reached
mibFaultCode: 549
mibFaultName: fltSwVlanPortNsResourceStatus
moClass: sw:VlanPortNs
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/vlan-port-ns

fltFabricLanPinGroupEmpty

Fault Code: F0621

Message

LAN Pin Group [name] is empty

Explanation

This fault typically occurs when a LAN pin group does not contain any targets.

Recommended Action

If you see this fault, add a target to the LAN pin group.

Fault Details

Severity: minor
Cause: empty-pin-group
mibFaultCode: 621
mibFaultName: fltFabricLanPinGroupEmpty
moClass: fabric:LanPinGroup
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/lan-pin-group-[name]

fltAdaptorExtEthIfMisConnect

Fault Code: F0625

Message

Adapter [id] eth interface [id] in server [id] mis-connected

Explanation

The link for a network-facing adapter interface is misconnected. Cisco FPR Manager raises this fault when any of the following scenarios occur:

  • Cisco FPR Manager detects a new connectivity between a previously configured switch port or FEX port and the adapter’s external interface.
  • Cisco FPR Manager detects a misconnected link between a fabric interconnect or FEX and its non-peer adapter’s interface.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check whether the adapter link is connected to a port that belongs to its peer fabric interconnect or FEX.

Step 2blank.gif If that connectivity seems correct, reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: link-misconnected
mibFaultCode: 625
mibFaultName: fltAdaptorExtEthIfMisConnect
moClass: adaptor:ExtEthIf
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]

fltAdaptorHostEthIfMisConnect

Fault Code: F0626

Message

Adapter [id] eth interface [id] in server [id] mis-connected

Explanation

The link for a network-facing host interface is misconnected. Cisco FPR Manager raises this fault when any of the following scenarios occur:

  • Cisco FPR Manager detects a new connectivity between a previously configured switch port and the host Ethernet interface.
  • Cisco FPR Manager detects a misconnected link between the host interface and its non-peer fabric interconnect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check whether the host Ethernet interface is connected to a port belonging to its peer fabric interconnect.

Step 2blank.gif If connectivity seems correct, reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: link-misconnected
mibFaultCode: 626
mibFaultName: fltAdaptorHostEthIfMisConnect
moClass: adaptor:HostEthIf
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]

fltPowerBudgetPowerBudgetCmcProblem

Fault Code: F0635

Message

Power cap application failed for chassis [id]

Explanation

This fault typically occurs when the server CIMC has failed to enforce the configured power cap.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the power consumption of the chassis. If the chassis is consuming significantly more power than configured in the power cap, consider reducing the group cap so that the power consumption of other chassis consumption can be reduced to make up for the increase.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file for Cisco FPR Manager and the chassis and then contact Cisco TAC.

Fault Details

Severity: major
Cause: power-cap-fail
mibFaultCode: 635
mibFaultName: fltPowerBudgetPowerBudgetCmcProblem
moClass: power:Budget
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget

fltPowerBudgetPowerBudgetBmcProblem

Fault Code: F0637

Message

Power cap application failed for server [chassisId]/[slotId]Power cap application failed for server [id]

Explanation

This fault typically occurs when the server CIMC or BIOS has failed to enforce the configured power cap.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the power consumption of the blade server. If the server is consuming significantly more power than configured in the power cap, switch to a manual per blade cap configuration. If the power consumption is still too high, consider reducing the group cap so that the power consumption of other chassis consumption can be reduced to make up for the increase.

Step 2blank.gif If the power consumption is still too high, the CIMC or BIOS software is likely faulty.

Step 3blank.gif Create a show tech-support file for Cisco FPR Manager and the chassis and then contact Cisco TAC.

Fault Details

Severity: major
Cause: power-cap-fail
mibFaultCode: 637
mibFaultName: fltPowerBudgetPowerBudgetBmcProblem
moClass: power:Budget
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget

fltPowerBudgetPowerBudgetDiscFail

Fault Code: F0640

Message

Insufficient power available to discover server [chassisId]/[slotId]Insufficient power available to discover server [id]

Explanation

This fault typically occurs when discovery fails due to unavailable power in the group.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Consider increasing the group cap.

Step 2blank.gif Reduce the number of blade servers or chassis in the Cisco FPR instance.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-cap-fail
mibFaultCode: 640
mibFaultName: fltPowerBudgetPowerBudgetDiscFail
moClass: power:Budget
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget

fltPowerGroupPowerGroupInsufficientBudget

Fault Code: F0642

Message

insufficient budget for power group [name]

Explanation

This fault typically occurs when the group cap is insufficient to meet the minimum hardware requirements.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Consider increasing the group cap.

Step 2blank.gif Reduce the number of blade servers or chassis in the Cisco FPR instance.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-cap-fail
mibFaultCode: 642
mibFaultName: fltPowerGroupPowerGroupInsufficientBudget
moClass: power:Group
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/power-ep/group-[name]

fltPowerGroupPowerGroupBudgetIncorrect

Fault Code: F0643

Message

admin committed insufficient for power group [name], using previous value [operCommitted]

Explanation

This fault typically occurs when the group cap is insufficient to meet the minimum hardware requirements. Under these circumstances, Cisco FPR Manager uses the previously entered group cap for provisioning.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Consider increasing the group cap.

Step 2blank.gif Reduce the number of blade servers or chassis in the Cisco FPR instance.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-cap-fail
mibFaultCode: 643
mibFaultName: fltPowerGroupPowerGroupBudgetIncorrect
moClass: power:Group
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/power-ep/group-[name]

fltMgmtIfMisConnect

Fault Code: F0688

Message

Management Port [id] in server [id] is mis connected

Explanation

This fault occurs when the server and FEX connectivity changes.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the connectivity between the server and FEX.

Step 2blank.gif If the connectivity was changed by mistake, restore it to its previous configuration.

Step 3blank.gif If the connectivity change was intentional, reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: link-misconnected
mibFaultCode: 688
mibFaultName: fltMgmtIfMisConnect
moClass: mgmt:If
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]

fltLsComputeBindingAssignmentRequirementsNotMet

Fault Code: F0689

Message

Assignment of service profile [name] to server [pnDn] failed

Explanation

The server could not be assigned to the selected service profile. This fault typically occurs as a result of one of the following issues:

  • The selected server does not meet the requirements of the service profile.
  • If the service profile was configured for restricted migration, the selected server does not match the currently or previously assigned server.

Recommended Action

If you see this fault, select a different server that meets the requirements of the service profile or matches the currently or previously assigned server.

Fault Details

Severity: minor
Cause: assignment-failed
mibFaultCode: 689
mibFaultName: fltLsComputeBindingAssignmentRequirementsNotMet
moClass: ls:ComputeBinding
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/pn
Affected MO: org-[name]/ls-[name]/pn-req
Affected MO: org-[name]/tier-[name]/ls-[name]/pn
Affected MO: org-[name]/tier-[name]/ls-[name]/pn-req

fltEquipmentFexPost-failure

Fault Code: F0702

Message

fex [id] POST failure

Explanation

This fault typically occurs when a FEX encounters errors during the Power On Self Test (POST). The impact of this fault varies depending on which errors were encountered during POST.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the POST results for the FEX. In the Cisco FPR Manager GUI, you can access the POST results from the General tab for the FEX. In the Cisco FPR Manager CLI, you can access the POST results by entering the show post command under the scope for the FEX.

Step 2blank.gif Reboot the FEX.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-problem
mibFaultCode: 702
mibFaultName: fltEquipmentFexPostFailure
moClass: equipment:Fex
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/fex-[id]

fltEquipmentFexIdentity

Fault Code: F0703

Message

Fex [id] has a malformed FRU

Explanation

This fault typically occurs when the FRU information for a FEX is corrupted or malformed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fru-problem
mibFaultCode: 703
mibFaultName: fltEquipmentFexIdentity
moClass: equipment:Fex
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/fex-[id]

fltAdaptorHostEthIfMissing

Fault Code: F0708

Message

Connection to Adapter [id] eth interface [id] in server [id] missing

Explanation

The link for a network-facing host interface is missing. Cisco FPR Manager raises this fault when it detects missing connectivity between a previously configured switch port and its previous peer host interface.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check whether the adapter link is connected to a port that belongs to its non-peer fabric interconnect.

Step 2blank.gif If that connectivity seems correct, reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: link-missing
mibFaultCode: 708
mibFaultName: fltAdaptorHostEthIfMissing
moClass: adaptor:HostEthIf
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]

fltPortPIoInvalid-sfp

Fault Code: F0713

Message

[transport] port [portId] on chassis [id] role : [ifRole] transceiver type:[xcvrType][transport] port [slotId]/[aggrPortId]/[portId] on fabric interconnect [id] role : [ifRole] transceiver type:[xcvrType][transport] port [slotId]/[portId] on fabric interconnect [id] role : [ifRole] transceiver type:[xcvrType]

Explanation

This fault is raised against a fabric interconnect port, network-facing IOM port, or FEX module port if an unsupported transceiver type is inserted. The port cannot be used if it has an unsupported transceiver.

Recommended Action

If you see this fault, replace the transceiver with a supported SFP type. Refer to the documentation on the Cisco website for a list of supported SFPs.

Fault Details

Severity: major
Cause: unsupported-transceiver
mibFaultCode: 713
mibFaultName: fltPortPIoInvalidSfp
moClass: port:PIo
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]

fltMgmtIfMissing

Fault Code: F0717

Message

Connection to Management Port [id] in server [id] is missing

Explanation

This fault occurs when the connectivity between a server and FEX is removed or unconfigured.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the connectivity between the server and FEX.

Step 2blank.gif If the connectivity was changed by mistake, restore it to its previous configuration.

Step 3blank.gif If the connectivity change was intentional, reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: link-missing
mibFaultCode: 717
mibFaultName: fltMgmtIfMissing
moClass: mgmt:If
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]

fltFabricEthLanPcEpDown

Fault Code: F0727

Message

[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]

Explanation

This fault typically occurs when a member port in an Ethernet port channel is down.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the link connectivity on the upstream Ethernet switch.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: membership-down
mibFaultCode: 727
mibFaultName: fltFabricEthLanPcEpDown
moClass: fabric:EthLanPcEp
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]

fltEquipmentIOCardThermalThresholdNonCritical

Fault Code: F0729

Message

[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]

Explanation

This fault occurs when the temperature of an I/O module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis and I/O module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: thermal-problem
mibFaultCode: 729
mibFaultName: fltEquipmentIOCardThermalThresholdNonCritical
moClass: equipment:IOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentIOCardThermalThresholdCritical

Fault Code: F0730

Message

[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]

Explanation

This fault occurs when the temperature of an I/O module has exceeded a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis and I/O module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace the faulty I/O modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 730
mibFaultName: fltEquipmentIOCardThermalThresholdCritical
moClass: equipment:IOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentIOCardThermalThresholdNonRecoverable

Fault Code: F0731

Message

[side] IOM [chassisId]/[id] ([switchId]) temperature: [thermal]

Explanation

This fault occurs when the temperature of an I/O module has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the chassis and I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis and I/O module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace the faulty I/O modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 731
mibFaultName: fltEquipmentIOCardThermalThresholdNonRecoverable
moClass: equipment:IOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/slot-[id]
Affected MO: sys/fex-[id]/slot-[id]

fltEquipmentChassisSeeprom-inoperable

Fault Code: F0733

Message

Device [id] SEEPROM operability: [seepromOperState]

Explanation

This fault occurs in the unlikely event that the Chassis shared storage (SEEPROM) is not operational.

Recommended Action

If you see this fault, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-inoperable
mibFaultCode: 733
mibFaultName: fltEquipmentChassisSeepromInoperable
moClass: equipment:Chassis
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltExtmgmtIfMgmtifdown

Fault Code: F0736

Message

Management interface on Fabric Interconnect [id] is [operState]

Explanation

This fault occurs when a fabric interconnect reports that the operational state of an external management interface is down.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the state transitions of the external management interface on the fabric interconnect.

Step 2blank.gif Check the link connectivity for the external management interface.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: mgmtif-down
mibFaultCode: 736
mibFaultName: fltExtmgmtIfMgmtifdown
moClass: extmgmt:If
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/extmgmt-intf

fltPowerChassisMemberPowerGroupCapInsufficient

Fault Code: F0740

Message

Chassis [id] cannot be capped as group cap is low. Please consider raising the cap.

Explanation

This fault typically occurs when an updated group cap is insufficient to meet the minimum hardware requirements and a chassis that has just been added to the power group cannot be capped as a result.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Consider increasing the group cap.

Step 2blank.gif Reduce the number of blade servers or chassis in the Cisco FPR instance.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: group-cap-insufficient
mibFaultCode: 740
mibFaultName: fltPowerChassisMemberPowerGroupCapInsufficient
moClass: power:ChassisMember
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/power-ep/group-[name]/ch-member-[id]

fltPowerChassisMemberChassisFirmwareProblem

Fault Code: F0741

Message

Chassis [id] cannot be capped as at least one of the CMC or CIMC or BIOS firmware version is less than 1.4. Please upgrade the firmware for cap to be applied.

Explanation

This fault typically occurs when the CIMC firmware on a server is an earlier release than Cisco FPR, Release 1.4.

Recommended Action

If you see this fault, consider upgrading the CIMC firmware, and the entire Cisco FPR instance if necessary, to Cisco FPR, Release 1.4 or later.

Fault Details

Severity: major
Cause: old-chassis-component-firmware
mibFaultCode: 741
mibFaultName: fltPowerChassisMemberChassisFirmwareProblem
moClass: power:ChassisMember
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/power-ep/group-[name]/ch-member-[id]

fltPowerChassisMemberChassisPsuInsufficient

Fault Code: F0742

Message

Chassis [id] cannot be capped as at least two PSU need to be powered

Explanation

This fault typically occurs when at least two PSUs are not powered on.

Recommended Action

If you see this fault, insert at least two PSUs and power them on.

Fault Details

Severity: major
Cause: psu-insufficient
mibFaultCode: 742
mibFaultName: fltPowerChassisMemberChassisPsuInsufficient
moClass: power:ChassisMember
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/power-ep/group-[name]/ch-member-[id]

fltPowerChassisMemberChassisPsuRedundanceFailure

Fault Code: F0743

Message

Chassis [id] was configured for redundancy, but running in a non-redundant configuration.

Explanation

This fault typically occurs when chassis power redundancy has failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Consider adding more PSUs to the chassis.

Step 2blank.gif Replace any non-functional PSUs.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: psu-redundancy-fail
mibFaultCode: 743
mibFaultName: fltPowerChassisMemberChassisPsuRedundanceFailure
moClass: power:ChassisMember
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/power-ep/group-[name]/ch-member-[id]

fltPowerBudgetPowerCapReachedCommit

Fault Code: F0744

Message

P-State lowered as consumption hit power cap for server [chassisId]/[slotId]P-State lowered as consumption hit power cap for server [id]

Explanation

This fault typically occurs when Cisco FPR Manager is actively capping the power for a blade server.

Recommended Action

If you see this fault, no action is needed.

Fault Details

Severity: info
Cause: power-consumption-hit-limit
mibFaultCode: 744
mibFaultName: fltPowerBudgetPowerCapReachedCommit
moClass: power:Budget
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget

fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure

Fault Code: F0747

Message

Auto core transfer failure at remote server [hostname]:[path] [exportFailureReason]

Explanation

This fault occurs when Cisco Firepower Manager cannot transfer a core file to a remote TFTP server. This is typically the result of one of the following issues:

  • The remote TFTP server is not accessible.
  • One or more of the parameters for the TFTP server that are specified for the core export target, such as path, port, and server name, are incorrect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify the connectivity to the remote server.

Step 2blank.gif Verify the path information of the remote server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: tftp-server-error
mibFaultCode: 747
mibFaultName: fltSysdebugAutoCoreFileExportTargetAutoCoreTransferFailure
moClass: sysdebug:AutoCoreFileExportTarget
Type: sysdebug
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/sysdebug/file-export

fltFabricMonSpanConfigFail

Fault Code: F0757

Message

Configuration for traffic monitor [name] failed, reason: [configFailReason]

Explanation

This fault typically occurs when the configuration of a traffic monitoring session is incorrect.

Recommended Action

If you see this fault, correct the configuration problem provided in the fault description.

Fault Details

Severity: major
Cause: config-error
mibFaultCode: 757
mibFaultName: fltFabricMonSpanConfigFail
moClass: fabric:Mon
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lanmon/[id]/eth-mon-[name]

fltPowerBudgetChassisPsuInsufficient

Fault Code: F0764

Message

Chassis [id] cannot be capped as the available PSU power is not enough for the chassis and the blades. Please correct the problem by checking input power or replace the PSU

Explanation

This fault typically occurs when the available PSU power is not enough to deploy the power budget of chassis and blades.

Recommended Action

If you see this fault, check the PSU input power or replace the PSU.

Fault Details

Severity: major
Cause: psu-insufficient
mibFaultCode: 764
mibFaultName: fltPowerBudgetChassisPsuInsufficient
moClass: power:Budget
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget

fltPowerBudgetTStateTransition

Fault Code: F0765

Message

Blade [chassisId]/[slotId] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliantRack server [id] has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant

Explanation

This fault typically occurs when the processor T-state is used to severely throttle the CPU.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Redeploy the power budget for the affected power group, blade server, or chassis.

Step 2blank.gif If the problem persists, reboot the blade server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: no-ack-from-bios
mibFaultCode: 765
mibFaultName: fltPowerBudgetTStateTransition
moClass: power:Budget
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget

fltPowerPolicyPowerPolicyApplicationFail

Fault Code: F0766

Message

Insufficient budget to apply no-cap priority through policy [name]. Blades will continue to be capped

Explanation

This fault occurs when a power policy cannot be applied to one or more blade servers. The affected blade servers cannot operate normally without power capping due to the limited power budget for those servers.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Increase the power budget for the blade servers in the power policy.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: no-cap-fail
mibFaultCode: 766
mibFaultName: fltPowerPolicyPowerPolicyApplicationFail
moClass: power:Policy
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/power-policy-[name]

fltMgmtIfNew

Fault Code: F0772

Message

New connection discovered on Management Port [id] in server [id]

Explanation

This fault occurs when the connectivity between a server and a FEX is added or changed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the connectivity between the server and FEX.

Step 2blank.gif If the connectivity was changed by mistake, restore it to its previous configuration.

Step 3blank.gif If the connectivity change was intentional, reacknowledge the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: new-link
mibFaultCode: 772
mibFaultName: fltMgmtIfNew
moClass: mgmt:If
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/mgmt/if-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/if-[id]
Affected MO: sys/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/if-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/if-[id]
Affected MO: sys/rack-unit-[id]/mgmt/if-[id]
Affected MO: sys/switch-[id]/mgmt/if-[id]

fltAdaptorExtEthIfMissing

Fault Code: F0775

Message

Connection to Adapter [id] eth interface [id] in server [id] missing

Explanation

The link for a network-facing adapter interface is misconnected. Cisco FPR Manager raises this fault when it detects that the connectivity between a previously configured port on a fabric interconnect or FEX and its prior peer network-facing adapter interface is misconnected or missing.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check whether the adapter interface is connected to a port belonging to its peer fabric interconnect or FEX.

Step 2blank.gif If the connectivity seems correct, reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: link-missing
mibFaultCode: 775
mibFaultName: fltAdaptorExtEthIfMissing
moClass: adaptor:ExtEthIf
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/ext-eth-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/ext-eth-[id]

fltStorageLocalDiskSlotEpUnusable

Fault Code: F0776

Message

Local disk [id] on server [serverId] is not usable by the operating system

Explanation

This fault occurs when the server disk drive is in a slot that is not supported by the storage controller.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Insert the server disk drive in a supported slot.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: equipment-inoperable
mibFaultCode: 776
mibFaultName: fltStorageLocalDiskSlotEpUnusable
moClass: storage:LocalDiskSlotEp
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/disk-[id]
Affected MO: sys/rack-unit-[id]/board/disk-[id]

fltFabricEthEstcPcEpDown

Fault Code: F0777

Message

[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]

Explanation

This fault typically occurs when a member port in an Ethernet port channel is down.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the link connectivity on the upstream Ethernet switch.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: membership-down
mibFaultCode: 777
mibFaultName: fltFabricEthEstcPcEpDown
moClass: fabric:EthEstcPcEp
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]

fltEquipmentFexIdentity-unestablishable

Fault Code: F0778

Message

Fex [id] has an invalid FRU

Explanation

This fault typically occurs because Cisco FPR Manager detected an unsupported chassis. For example, the model, vendor, or revision is not recognized.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: identity-unestablishable
mibFaultCode: 778
mibFaultName: fltEquipmentFexIdentityUnestablishable
moClass: equipment:Fex
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/fex-[id]

fltEquipmentFanModuleInoperable

Fault Code: F0794

Message

Fan module [tray]-[id] in chassis [id] operability: [operability]Fan module [tray]-[id] in server [id] operability: [operability]Fan module [tray]-[id] in fabric interconnect [id] operability: [operability]

Explanation

This fault occurs if a fan module is not operational.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove and reinstall the fan module. If multiple fans are affected by this fault, remove and reinstall one fan module at a time.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 794
mibFaultName: fltEquipmentFanModuleInoperable
moClass: equipment:FanModule
Type: equipment
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]

fltLsmaintMaintPolicyUnresolvableScheduler

Fault Code: F0795

Message

Schedule [schedName] referenced by maintenance policy [name] does not exist

Explanation

The schedule that is referenced by the maintenance policy does not exist. This fault typically occurs as a result of one of the following issues:

  • The schedule does not exist.
  • The schedule was deleted.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check if the named schedule exists. If it is deleted or missing, try to create it.

Step 2blank.gif If the named schedule is deleted or missing, recreate it.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: non-existent-scheduler
mibFaultCode: 795
mibFaultName: fltLsmaintMaintPolicyUnresolvableScheduler
moClass: lsmaint:MaintPolicy
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/maint-[name]

fltProcessorUnitIdentity-unestablishable

Fault Code: F0801

Message

Processor [id] on server [chassisId]/[slotId] has an invalid FRUProcessor [id] on server [id] has an invalid FRU

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported CPU in the server. For example, the model, vendor, or revision is not recognized.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, you may have an unsupported CPU configuration in the server. Create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: identity-unestablishable
mibFaultCode: 801
mibFaultName: fltProcessorUnitIdentityUnestablishable
moClass: processor:Unit
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltIqnpoolPoolEmpty

Fault Code: F0821

Message

iqn pool [name] is empty

Explanation

This fault typically occurs when an IQN pool does not contain any IQNs.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the pool is in use, add a block of IQNs to the pool.

Step 2blank.gif If the pool is not in use, ignore the fault.

Fault Details

Severity: minor
Cause: empty-pool
mibFaultCode: 821
mibFaultName: fltIqnpoolPoolEmpty
moClass: iqnpool:Pool
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/iqn-pool-[name]

fltFabricDceSwSrvPcEpDown

Fault Code: F0831

Message

[type] Member [slotId]/[aggrPortId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership][type] Member [slotId]/[portId] of Port-Channel [portId] on fabric interconnect [id] is down, membership: [membership]

Explanation

This fault typically occurs when a member port in a fabric port channel is down.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the link connectivity between the FEX or IOM and the fabric interconnect.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: membership-down
mibFaultCode: 831
mibFaultName: fltFabricDceSwSrvPcEpDown
moClass: fabric:DceSwSrvPcEp
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]

fltFabricEpMgrEpTransModeFail

Fault Code: F0832

Message

Port constraint violation on switch [id]: [confQual]

Explanation

This fault occurs when at least one logical interface is misconfigured. This can happen when upgrading to a different type or series of fabric interconnect or when importing a configuration.The configuration must meet the following constraints:

  • There must be at most one logical port per fabric interconnect ID/module ID/port ID.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Create a list of all logical interfaces that are misconfigured and have caused an ’error-misconfigured’ fault.

Step 2blank.gif For each logical interface, note the reason listed in the fault for the misconfiguration.

Step 3blank.gif Log into Cisco FPR Manager and correct each misconfigured logical interface. If you used the Cisco FPR Manager CLI, commit all changes.

Step 4blank.gif Review any faults or error messages that describe additional misconfigurations and correct those errors.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: config-error
mibFaultCode: 832
mibFaultName: fltFabricEpMgrEpTransModeFail
moClass: fabric:EpMgr
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/[id]

fltFabricPIoEpErrorMisconfigured

Fault Code: F0834

Message

Interface [name] is [operState]. Reason: [operStateReason]

Explanation

This fault occurs when a logical interface is misconfigured. This can happen when upgrading to a different type or series of fabric interconnect or when importing a configuration.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Create a list of all logical interfaces that are misconfigured and have caused an ’error-misconfigured’ fault.

Step 2blank.gif For each logical interface, note the reason listed in the fault for the misconfiguration.

Step 3blank.gif Log into Cisco FPR Manager and correct each misconfigured logical interface. If you used the Cisco FPR Manager CLI, commit all changes.

Step 4blank.gif Review any faults or error messages that describe additional misconfigurations and correct those errors.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: interface-misconfigured
mibFaultCode: 834
mibFaultName: fltFabricPIoEpErrorMisconfigured
moClass: fabric:PIoEp
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/net-group-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoe-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/san/net-[name]/sw-[switchId]-slot-[slotId]-aggr-port-[aggrPortId]/phys-switch-[switchId]-slot-[slotId]-port-[portId]
Affected MO: fabric/server/chassis-[chassisId]
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]
Affected MO: fabric/server/chassis-ep-ven-[vendor]-mod[model]-ser-[serial]
Affected MO: fabric/server/compute-ep-ven-[vendor]-mod-[model]-ser-[serial]
Affected MO: fabric/server/sw-[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/dest-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesanpcep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-eth-slot-[slotId]-port-[portId]/eth-target-ep-[name]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-fcoesanep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-port-[portId]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/tbh/border-eth/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]
Affected MO: sys/tbh/border-eth/pc-[portId]/eth-target-[name]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/eth-target-[name]

fltFabricEthLanEpMissingPrimaryVlan

Fault Code: F0835

Message

Primary vlan missing from fabric: [switchId], port: [slotId]/[aggrPortId]/[portId].Primary vlan missing from fabric: [switchId], port: [slotId]/[portId].

Explanation

This fault occurs when an uplink port or port channel is configured with a primary VLAN that does not exist in the Cisco FPR instance.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Update the configuration of the port or port channel to include a primary VLAN.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: missing-primary-vlan
mibFaultCode: 835
mibFaultName: fltFabricEthLanEpMissingPrimaryVlan
moClass: fabric:EthLanEp
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]

fltFabricEthLanPcMissingPrimaryVlan

Fault Code: F0836

Message

Primary vlan missing from fabric: [switchId], port-channel: [portId].

Explanation

This fault occurs when an uplink port or port channel is configured with a primary VLAN that does not exist in the Cisco FPR instance.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Update the configuration of the port or port channel to include a primary VLAN.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: missing-primary-vlan
mibFaultCode: 836
mibFaultName: fltFabricEthLanPcMissingPrimaryVlan
moClass: fabric:EthLanPc
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/[id]/pc-[portId]

fltVnicEtherPinningMismatch

Fault Code: F0840

Message

Hard pinning target for eth vNIC [name], service profile [name] does not have all the required vlans configured

Explanation

This fault occurs when one or more VLANs required by vNIC in a service profile are not configured on the target uplink port or port channel for a hard-pinned LAN pin group.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif In the LAN Uplinks Manager of the Cisco FPR Manager GUI, configure all of the VLANs in the vNIC in the target uplink port or port channel for the LAN pin group. If you prefer to use the Cisco FPR Manager CLI, navigate to scope /eth-uplink/vlan and create the required member ports for the LAN pin group.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: pinning-mismatch
mibFaultCode: 840
mibFaultName: fltVnicEtherPinningMismatch
moClass: vnic:Ether
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]

fltVnicEtherPinningMisconfig

Fault Code: F0841

Message

Hard pinning target for eth vNIC [name], service profile [name] is missing or misconfigured

Explanation

This fault occurs when one or more vNIC target uplink ports or port channels for a hard-pinned LAN pin group are either missing or misconfigured as the wrong port type.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the LAN pin group configuration.

Step 2blank.gif Correct the configuration of the port and port channels in the pin group.

Step 3blank.gif Ensure that all required vLANs are allowed on the target ports or port channels.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: pinning-misconfig
mibFaultCode: 841
mibFaultName: fltVnicEtherPinningMisconfig
moClass: vnic:Ether
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]

fltProcessorUnitDisabled

Fault Code: F0842

Message

Processor [id] on server [chassisId]/[slotId] operState: [operState]Processor [id] on server [id] operState: [operState]

Explanation

This fault occurs in the unlikely event that a processor is disabled.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If this fault occurs on a blade server, remove and reinsert the server into the chassis.

Step 2blank.gif In Cisco FPR Manager, decommission and recommission the blade server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-disabled
mibFaultCode: 842
mibFaultName: fltProcessorUnitDisabled
moClass: processor:Unit
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/cpu-[id]
Affected MO: sys/rack-unit-[id]/board/cpu-[id]

fltMemoryUnitDisabled

Fault Code: F0844

Message

DIMM [location] on server [chassisId]/[slotId] operState: [operState]DIMM [location] on server [id] operaState: [operState]

Explanation

This fault is raised when the server BIOS disables a DIMM. The BIOS could disable a DIMM for several reasons, including incorrect location of the DIMM or incompatible speed.

Recommended Action

If you see this fault, refer to the Cisco FPR B-Series Troubleshooting Guide for information on how to resolve the DIMM issues.

Fault Details

Severity: major
Cause: equipment-disabled
mibFaultCode: 844
mibFaultName: fltMemoryUnitDisabled
moClass: memory:Unit
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]/mem-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]/mem-[id]

fltFirmwareBootUnitActivateStatusFailed

Fault Code: F0856

Message

Activation failed and Activate Status set to failed.

Explanation

This fault typically occurs for the following reasons: when firmware activation fails, or if the after activation running image is not the corresponding startup image.

  • Firmware activation failed.
  • The version of firmware running on the server after activation is not the version listed in Cisco FPR Manager as the startup image.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Go to FSM tab for the endpoint on which the fault is raised and review the error description for the reason that the activation failed.

Step 2blank.gif If the FSM failed, review the error message in the FSM.

Step 3blank.gif If possible, correct the problem described in the error message.

Step 4blank.gif If the problem persists, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: activation-failed
mibFaultCode: 856
mibFaultName: fltFirmwareBootUnitActivateStatusFailed
moClass: firmware:BootUnit
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/fpga/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/rommon/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]

fltFabricInternalPcDown

Fault Code: F0858

Message

[type] port-channel [portId] on fabric interconnect [id] oper state: [operState], reason: [stateQual]

Explanation

This fault occurs when the transport VIF for a server is down. Cisco FPR Manager raises this fault when a fabric interconnect reports the connectivity state on virtual interface as one of the following:

  • Down
  • Errored
  • Unavailable

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the blade server discovery was successful.

Step 2blank.gif Check the states on all communicating ports from end to end.

Step 3blank.gif If connectivity seems correct, decommission and recommission the server.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: operational-state-down
mibFaultCode: 858
mibFaultName: fltFabricInternalPcDown
moClass: fabric:InternalPc
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/server/sw-[id]/pc-[portId]

fltMgmtEntityDevice-1-shared-storage-error

Fault Code: F0863

Message

device [chassis1], error accessing shared-storage

Explanation

This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.

Recommended Action

If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: device-shared-storage-error
mibFaultCode: 863
mibFaultName: fltMgmtEntityDevice1SharedStorageError
moClass: mgmt:Entity
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltMgmtEntityDevice-2-shared-storage error

Fault Code: F0864

Message

device [chassis2], error accessing shared-storage

Explanation

This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.

Recommended Action

If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: device-shared-storage-error
mibFaultCode: 864
mibFaultName: fltMgmtEntityDevice2SharedStorageError
moClass: mgmt:Entity
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltMgmtEntityDevice-3-shared-storage error

Fault Code: F0865

Message

device [chassis3], error accessing shared-storage

Explanation

This fault occurs in an unlikely event that the shared storage selected for writing the cluster state is not accessible. This fault is typically a transient fault. You might see this fault when one of the following occurs: (a) the Fabric Interconnect boots, (b) the IO Module is reset, (c) the rack server is reboot, or (d) system is upgraded/downgraded. If this fault is not cleared after the system returns to normal operation following the reboot/reset/upgrade/downgrade, then it may affect the full HA functionality of the Fabric Interconnect cluster.

Recommended Action

If this fault is not cleared even after the system returns to normal operation, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: device-shared-storage-error
mibFaultCode: 865
mibFaultName: fltMgmtEntityDevice3SharedStorageError
moClass: mgmt:Entity
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltMgmtEntityHa-ssh-keys-mismatched

Fault Code: F0866

Message

Fabric Interconnect [id], management services, mismatched SSH keys

Explanation

This fault indicates that one of the following scenarios has occurred:

  • The internal SSH keys used for HA in the cluster configuration are mismatched. This causes certain operations to fail.
  • Another fabric interconnect is connected to the primary fabric interconnect in the cluster without first erasing the existing configuration in the primary.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Log into the Cisco FPR Manager CLI on the subordinate fabric interconnect.

Step 2blank.gif Enter connect local-mgmt

Step 3blank.gif Enter erase configuration to erase the configuration on the subordinate fabric interconnect and reboot it.

Step 4blank.gif When the secondary fabric interconnect has rebooted, reconfigure it for the cluster.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: ha-ssh-keys-mismatched
mibFaultCode: 866
mibFaultName: fltMgmtEntityHaSshKeysMismatched
moClass: mgmt:Entity
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]

fltComputeBoardPowerFail

Fault Code: F0868

Message

Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [power]Motherboard of server [id] (service profile: [assignedToDn]) power: [power]

Explanation

This fault typically occurs when the power sensors on a blade server detect a problem.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove the blade server from the chassis.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: power-problem
mibFaultCode: 868
mibFaultName: fltComputeBoardPowerFail
moClass: compute:Board
Type: environmental
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/rack-unit-[id]/board

fltVmVifLinkState

Fault Code: F0876

Message

Virtual interface [vifId] link is down; reason [stateQual]

Explanation

This fault occurs when Cisco FPR cannot send or receive data through an uplink port.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Enable the failed uplink port.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: vif-down
mibFaultCode: 876
mibFaultName: fltVmVifLinkState
moClass: vm:Vif
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: vmm/computeEp-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/hv-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]
Affected MO: vmm/vm-[uuid]/nic-[name]/sw-[phSwitchId]vif-[vifId]

fltEquipmentPsuPowerSupplyShutdown

Fault Code: F0881

Message

Power supply [id] in chassis [id] shutdown reason:[powerStateQualifier]

Explanation

This fault typically occurs when a power supply unit in a chassis, fabric interconnect, or a FEX is shut down, either due to higher than expected power current, higher than expected temperatures, or the failure of a fan.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the server.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the servers have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis or rack server are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Verify that the power cord is properly connected to the PSU and the power source.

Step 7blank.gif Verify that the power source is 220 volts.

Step 8blank.gif Verify that the PSU is properly installed in the chassis or fabric interconnect.

Step 9blank.gif Remove the PSU and reinstall it.

Step 10blank.gif Replace the PSU.

Step 11blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-offline
mibFaultCode: 881
mibFaultName: fltEquipmentPsuPowerSupplyShutdown
moClass: equipment:Psu
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuPowerThreshold

Fault Code: F0882

Message

Power supply [id] on chassis [id] has exceeded its power thresholdPower supply [id] on server [id] has exceeded its power threshold

Explanation

This fault occurs when a power supply unit is drawing too much current.

Recommended Action

If you see this fault, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: power-problem
mibFaultCode: 882
mibFaultName: fltEquipmentPsuPowerThreshold
moClass: equipment:Psu
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltEquipmentPsuInputError

Fault Code: F0883

Message

Power supply [id] on chassis [id] has disconnected cable or bad input voltagePower supply [id] on server [id] has disconnected cable or bad input voltage

Explanation

This fault occurs when a power cable is disconnected or input voltage is incorrect.

Recommended Action

If you see this fault, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: power-problem
mibFaultCode: 883
mibFaultName: fltEquipmentPsuInputError
moClass: equipment:Psu
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/psu-[id]
Affected MO: sys/fex-[id]/psu-[id]
Affected MO: sys/rack-unit-[id]/psu-[id]
Affected MO: sys/switch-[id]/psu-[id]

fltNetworkElementInventoryFailed

Fault Code: F0885

Message

Fabric Interconnect [id] inventory is not complete [inventoryStatus]

Explanation

Cisco FPR Manager raises this fault when the management subsystem is unable to perform an inventory of the physical components, such as I/O cards or physical ports.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Ensure that both fabric interconnects in an HA cluster are running the same software versions.

Step 2blank.gif Ensure that the fabric interconnect software is a version that is compatible with the Cisco FPR Manager software.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: inventory-failed
mibFaultCode: 885
mibFaultName: fltNetworkElementInventoryFailed
moClass: network:Element
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]

fltAdaptorUnitExtnUnidentifiable-fru

Fault Code: F0900

Message

Adapter extension [id] in server [chassisId]/[slotId] has unidentified FRU

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported adapter unit extension, such as a pass-through adaptor. For example, the model, vendor, or revision is not recognized.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that a supported adapter unit extension is installed.

Step 2blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: unidentifiable-fru
mibFaultCode: 900
mibFaultName: fltAdaptorUnitExtnUnidentifiableFru
moClass: adaptor:UnitExtn
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]

fltAdaptorUnitExtnMissing

Fault Code: F0901

Message

Adapter extension [id] in server [chassisId]/[slotId] presence: [presence]

Explanation

This fault typically occurs when an I/O adapter unit extension, such as a pass-through adapter, is missing. Cisco FPR Manager raises this fault when any of the following scenario occur:

  • The endpoint reports there is no adapter unit extension, such as a pass-through adapter, plugged into the adapter slot.
  • The endpoint cannot detect or communicate with the adapter unit extension plugged into the adapter slot.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Ensure the adapter unit extension is properly plugged into an adapter slot in the server.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: equipment-missing
mibFaultCode: 901
mibFaultName: fltAdaptorUnitExtnMissing
moClass: adaptor:UnitExtn
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/adaptor-extn-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/adaptor-extn-[id]

fltEquipmentFexFex-unsupported

Fault Code: F0902

Message

Fex [id] with model [model] is unsupported

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported FEX. For example, the model, vendor, or revision is not recognized.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that a supported FEX is installed.

Step 2blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: fex-unsupported
mibFaultCode: 902
mibFaultName: fltEquipmentFexFexUnsupported
moClass: equipment:Fex
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/fex-[id]

fltVnicIScsiConfig-failed

Fault Code: F0903

Message

iSCSI vNIC [name], service profile [name] has duplicate iqn name [initiatorName]

Explanation

This fault typically occurs when IScsi Vnics refer the same iqn name.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Make sure that iqn name unique per iSCSI vnic.

Step 2blank.gif Using show identity iqn check if the iSCSI vnic is registered in the universe.

Step 3blank.gif Try non disruptive actions such as changing description on the Service Profile to register the iqn in the universe.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: configuration-failed
mibFaultCode: 903
mibFaultName: fltVnicIScsiConfigFailed
moClass: vnic:IScsi
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/iscsi-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/iscsi-[name]

fltPkiKeyRingStatus

Fault Code: F0909

Message

[name] Keyring’s certificate is invalid, reason: [certStatus].

Explanation

This fault occurs when certificate status of Keyring has become invalid.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: invalid-keyring-certificate
mibFaultCode: 909
mibFaultName: fltPkiKeyRingStatus
moClass: pki:KeyRing
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/pki-ext/keyring-[name]

fltPkiTPStatus

Fault Code: F0910

Message

[name] Trustpoint’s cert-chain is invalid, reason: [certStatus].

Explanation

This fault occurs when certificate status of TrustPoint has become invalid.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: invalid-trustpoint-cert-chain
mibFaultCode: 910
mibFaultName: fltPkiTPStatus
moClass: pki:TP
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/pki-ext/tp-[name]

fltComputePhysicalDisassociationFailed

Fault Code: F0915

Message

Failed to disassociate server [id]Failed to disassociate server [chassisId]/[slotId]

Explanation

This fault typically occurs for one of the following reasons:

  • The server is down.
  • The data path is not working.
  • Cisco FPR Manager cannot communicate with one or more of the fabric interconnect, the server, or a component on the server.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the communication path to the server including fabric interconnect server ports, IOM link and the current state of the server

Step 2blank.gif If the server is stuck in an inappropriate state, such as booting, power cycle the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: disassociation-failed
mibFaultCode: 915
mibFaultName: fltComputePhysicalDisassociationFailed
moClass: compute:Physical
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltComputePhysicalNetworkMisconfigured

Fault Code: F0916

Message

Server [id] (service profile: [assignedToDn]) has mis-configured network vif resourcesServer [chassisId]/[slotId] (service profile: [assignedToDn]) has mis-configured network vif resources

Explanation

This fault would occur when FPRM VIF-id Map is not the same as the VIF-id map deployed on the adaptor upon Full Backup-Restore etc.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Re-acknowledge the server. This will trigger Deep Discovery-Deep Association & will resolve the issue

Step 2blank.gif If the above actions did not resolve the issue, execute the show tech-support command and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: vif-ids-mismatch
mibFaultCode: 916
mibFaultName: fltComputePhysicalNetworkMisconfigured
moClass: compute:Physical
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltVnicProfileProfileConfigIncorrect

Fault Code: F0917

Message

The Port Profile [name] has an invalid configuration.

Explanation

This fault occurs there is an invalid entry for a port profile configuration.

Recommended Action

Check documentation and correct the offending entry in the port profile configuration.

Fault Details

Severity: warning
Cause: profile-config-incorrect
mibFaultCode: 917
mibFaultName: fltVnicProfileProfileConfigIncorrect
moClass: vnic:Profile
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/profiles/vnic-[name]

fltVnicEtherIfVlanAccessFault

Fault Code: F0932

Message

The named vlan [name] for vNIC [name] cannot be accessed from org [name]

Explanation

This fault typically occurs when a Service Profile’s vnic interface (LAN) is resolvable but the service profile does not have access to the vlan. In this case, the default vlan will be used.

Recommended Action

This fault will be removed if you perform one of the following actions:


Step 1blank.gif Change the vnic’s interface name to a VLAN that you have access to.

Step 2blank.gif If you wish to use the default vlan, change the vnic’s interface name to default.

Step 3blank.gif Configure access to the named vlan by creating a vlan permit or vlan group permit in the service profile’s org (or a parent org).

Fault Details

Severity: major
Cause: inaccessible-vlan-referenced
mibFaultCode: 932
mibFaultName: fltVnicEtherIfVlanAccessFault
moClass: vnic:EtherIf
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]

fltVnicEtherIfVlanUnresolvable

Fault Code: F0933

Message

The named vlan [name] for vNIC [name] cannot be resolved

Explanation

This fault (warning) occurs when a Service Profile’s vnic interface (LAN) is unresolvable. In this case, the default vlan will be used as the operational vlan.

Recommended Action

This fault will be removed if you perform one of the following actions:


Step 1blank.gif Change the vnic interface name to an existing VLAN.

Step 2blank.gif Create the named vlan.

Fault Details

Severity: warning
Cause: referenced-vlan-unresolvable
mibFaultCode: 933
mibFaultName: fltVnicEtherIfVlanUnresolvable
moClass: vnic:EtherIf
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]

fltVnicEtherIfInvalidVlan

Fault Code: F0934

Message

Invalid Vlan in the allowed vlan list

Explanation

This fault typically occurs when a vnic of a service profile or a port profile contains an invalid vlan. an invalid vlan can be any one of the following:


Step 1blank.gif an isolated vlan or a community vlan that is not associated to a valid primary vlan

Step 2blank.gif a primary vlan without any of its assoicated secondary vlans allowed on the vnic

Step 3blank.gif a vlan which has sharing-type or primary vlan name not matching to that of vlan in lan-side/appliance-side

Recommended Action

This fault will be removed if you perform one of the following actions:


Step 1blank.gif if invalid vlan is an isolated or community vlan then make sure it is mapped to a valid primary vlan.

Step 2blank.gif if invalid vlan is a primary vlan then either allow any of its secondary vlans or delete it from vnic or port profile.

Step 3blank.gif if invalid vlan is a vlan that does not match the sharing properties with the vlan of same vlan id in the lan-side/appliance-side, change the properties of this vlan to be the same as the other.

Fault Details

Severity: major
Cause: invalid-vlan-in-the-allowed-vlan-list
mibFaultCode: 934
mibFaultName: fltVnicEtherIfInvalidVlan
moClass: vnic:EtherIf
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]

fltFabricVlanVlanConflictPermit

Fault Code: F0935

Message

There are multiple vlans with id [id] have different accessability configured.

Explanation

This fault occurs when multipl global vlans with the same id have different access configurations.

Recommended Action

Change the access configuration by configuring VLAN/VLAN Group Permits.

Fault Details

Severity: warning
Cause: vlan-conflict-permit
mibFaultCode: 935
mibFaultName: fltFabricVlanVlanConflictPermit
moClass: fabric:Vlan
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]

fltFabricVlanReqVlanPermitUnresolved

Fault Code: F0936

Message

The VLAN permit does not reference any existing vlans.

Explanation

This fault occurs when a VLAN permit exists but there are no vnics by the name.

Recommended Action

Delete the VLAN permit, create the referenced VLAN (or ignore).

Fault Details

Severity: warning
Cause: vlan-permit-unresolved
mibFaultCode: 936
mibFaultName: fltFabricVlanReqVlanPermitUnresolved
moClass: fabric:VlanReq
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/vlan-req-[name]

fltFabricVlanGroupReqVlanGroupPermitUnresolved

Fault Code: F0937

Message

The VLAN permit does not reference any existing net groups.

Explanation

This fault occurs when a VLAN group permit exists but there are no referenced network groups.

Recommended Action

Delete the VLAN permit, create the referenced VLAN (or ignore).

Fault Details

Severity: warning
Cause: group-permit-unresolved
mibFaultCode: 937
mibFaultName: fltFabricVlanGroupReqVlanGroupPermitUnresolved
moClass: fabric:VlanGroupReq
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/vlan-group-req-[name]

fltExtpolClientClientLostConnectivity

Fault Code: F0988

Message

FPRM has lost connectivity with Firepower Central

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: client-lost-connectivity
mibFaultCode: 988
mibFaultName: fltExtpolClientClientLostConnectivity
moClass: extpol:Client
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltStorageLocalDiskDegraded

Fault Code: F0996

Message

Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

This fault occurs when the local disk has become degraded. The fault description will contain the physical drive state, which indicates the reason for the degradation.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the drive state is "rebuild" or "copyback", wait for the rebuild or copyback operation to complete.

Step 2blank.gif If the drive state is "predictive-failure", replace the disk.

Fault Details

Severity: warning
Cause: equipment-degraded
mibFaultCode: 996
mibFaultName: fltStorageLocalDiskDegraded
moClass: storage:LocalDisk
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]

fltStorageRaidBatteryDegraded

Fault Code: F0997

Message

RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

This fault occurs when the RAID backup unit is degraded.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the fault reason indicates the backup unit is in a relearning cycle, wait for relearning to complete.

Step 2blank.gif If the fault reason indicates the backup unit is about to fail, replace the backup unit.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: equipment-degraded
mibFaultCode: 997
mibFaultName: fltStorageRaidBatteryDegraded
moClass: storage:RaidBattery
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery

fltStorageRaidBatteryRelearnAborted

Fault Code: F0998

Message

RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when the backup unit’s relearning cycle was aborted.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Retry the learn cycle.

Step 2blank.gif Replace the backup unit.

Fault Details

Severity: minor
Cause: equipment-degraded
mibFaultCode: 998
mibFaultName: fltStorageRaidBatteryRelearnAborted
moClass: storage:RaidBattery
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: false
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery

fltStorageRaidBatteryRelearnFailed

Fault Code: F0999

Message

RAID Battery on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]RAID Battery on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when the backup unit’s relearning cycle has failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Retry the learn cycle.

Step 2blank.gif Replace the backup unit.

Fault Details

Severity: major
Cause: equipment-degraded
mibFaultCode: 999
mibFaultName: fltStorageRaidBatteryRelearnFailed
moClass: storage:RaidBattery
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: false
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/raid-battery
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/raid-battery

fltStorageInitiatorConfiguration-error

Fault Code: F1001

Message

Initiator [name] either cannot be resolved or does not match with one of the storage targets. No zones are deployed for this initiator and the target.

Explanation

Initiator either cannot be resolved or does not match with one of the targets.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check if vhba interface referenced by this Initiator exsits.

Step 2blank.gif Check if switch id or vsan name of the vhba interface referenced by this Initiator matches one of the targets.

Fault Details

Severity: warning
Cause: configuration-error
mibFaultCode: 1001
mibFaultName: fltStorageInitiatorConfigurationError
moClass: storage:Initiator
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/san-conn-pol-[name]/grp-[name]/ini-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/grp-[name]/ini-[name]

fltStorageControllerPatrolReadFailed

Fault Code: F1003

Message

Controller [id] on server [chassisId]/[slotId] had a patrol read failure. Reason: [operQualifierReason]Controller [id] on server [id] had a patrol read failure. Reason: [operQualifierReason]

Explanation

NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a Patrol Read operation has failed.

Recommended Action

Re-run the patrol read operation.

Fault Details

Severity: warning
Cause: operation-failed
mibFaultCode: 1003
mibFaultName: fltStorageControllerPatrolReadFailed
moClass: storage:Controller
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: false
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]

fltStorageControllerInoperable

Fault Code: F1004

Message

Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]Controller [id] on server [id] is inoperable. Reason: [operQualifierReason]

Explanation

This fault occurs when the storage controller is inaccessible.

Recommended Action

For PCI and mezz-based storage controllers, check the seating of the storage controller. If the problem persists, replace the controller.

Fault Details

Severity: critical
Cause: equipment-inoperable
mibFaultCode: 1004
mibFaultName: fltStorageControllerInoperable
moClass: storage:Controller
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]

fltStorageLocalDiskRebuildFailed

Fault Code: F1005

Message

Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a rebuild operation has failed. This may cause a degradation in performance.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Retry the rebuild operation.

Step 2blank.gif Replace the disk.

Fault Details

Severity: major
Cause: equipment-offline
mibFaultCode: 1005
mibFaultName: fltStorageLocalDiskRebuildFailed
moClass: storage:LocalDisk
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: false
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]

fltStorageLocalDiskCopybackFailed

Fault Code: F1006

Message

Local disk [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Local disk [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a copyback operation has failed. This may cause a degradation in performance.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Retry the copyback operation.

Step 2blank.gif Replace the disk.

Fault Details

Severity: major
Cause: equipment-offline
mibFaultCode: 1006
mibFaultName: fltStorageLocalDiskCopybackFailed
moClass: storage:LocalDisk
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: false
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]

fltStorageVirtualDriveInoperable

Fault Code: F1007

Message

Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

This fault occurs when the virtual drive has become inoperable.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify the presence and health of disks that are used by the virtual drive.

Step 2blank.gif If applicable, reseat or replace used disks.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-inoperable
mibFaultCode: 1007
mibFaultName: fltStorageVirtualDriveInoperable
moClass: storage:VirtualDrive
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]

fltStorageVirtualDriveDegraded

Fault Code: F1008

Message

Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

This fault occurs when the virtual drive has become degraded. The fault description will contain the physical drive state, which indicates the reason for the degradation.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If the drive is performing a consistency check operation, wait for the operation to complete.

Step 2blank.gif Verify the presence and health of disks that are used by the virtual drive.

Step 3blank.gif If applicable, reseat or replace used disks.

Step 4blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-degraded
mibFaultCode: 1008
mibFaultName: fltStorageVirtualDriveDegraded
moClass: storage:VirtualDrive
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]

fltStorageVirtualDriveReconstructionFailed

Fault Code: F1009

Message

Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a drive reconstruction operation has failed. This may cause a degradation in performance.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Retry the reconstruction operation.

Step 2blank.gif Delete and recreate the virtual drive.

Fault Details

Severity: major
Cause: equipment-degraded
mibFaultCode: 1009
mibFaultName: fltStorageVirtualDriveReconstructionFailed
moClass: storage:VirtualDrive
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: false
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]

fltStorageVirtualDriveConsistencyCheckFailed

Fault Code: F1010

Message

Virtual drive [id] on server [chassisId]/[slotId] operability: [operability]. Reason: [operQualifierReason]Virtual drive [id] on server [id] operability: [operability]. Reason: [operQualifierReason]

Explanation

NOTE: This fault is not currently implemented by Firepower ManagerThis fault is present only as a placeholder, possibly for another release,such as stand-alone rack servers.---This fault occurs when a drive consistency check operation has failed. This may cause a degradation in performance.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Retry the consistency check operation.

Step 2blank.gif Delete and recreate the virtual drive.

Fault Details

Severity: major
Cause: equipment-degraded
mibFaultCode: 1010
mibFaultName: fltStorageVirtualDriveConsistencyCheckFailed
moClass: storage:VirtualDrive
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: false
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/vd-[id]

fltAaaProviderGroupProvidergroup

Fault Code: F1026

Message

For [dn]: Server Group with name [name] already exist, You need to specify a unique name for this object.

Explanation

This fault typically occurs because Cisco FPR Manager has detected multiple provider-groups with same name.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Need to delete the duplicate provider group configured causing this problem.

Fault Details

Severity: major
Cause: provider-group-already-exists
mibFaultCode: 1026
mibFaultName: fltAaaProviderGroupProvidergroup
moClass: aaa:ProviderGroup
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]

fltAaaConfigServergroup

Fault Code: F1027

Message

For [dn]: [realm] Server Group with name [providerGroup] doesn’t exist or is not deployed.

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported authentication method.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that server group configured for authentication is present.

Step 2blank.gif If the server group is not configured, create the server group to use for authentication.

Fault Details

Severity: critical
Cause: invalid-server-group
mibFaultCode: 1027
mibFaultName: fltAaaConfigServergroup
moClass: aaa:Config
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/auth-realm/console-auth
Affected MO: sys/auth-realm/default-auth
Affected MO: sys/auth-realm/domain-[name]/domain-auth

fltAaaRoleRoleNotDeployed

Fault Code: F1028

Message

Role [name] can’t be deployed. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported role.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that total number of roles is less than maximum supported roles.

Step 2blank.gif Verify that sum of privileges across all roles is less than maximum privileges sum.

Fault Details

Severity: critical
Cause: role-config-error
mibFaultCode: 1028
mibFaultName: fltAaaRoleRoleNotDeployed
moClass: aaa:Role
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/user-ext/role-[name]

fltAaaLocaleLocaleNotDeployed

Fault Code: F1029

Message

Locale [name] can’t be deployed. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported locale.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that total number of locale is less than maximum supported roles.

Fault Details

Severity: critical
Cause: locale-config-error
mibFaultCode: 1029
mibFaultName: fltAaaLocaleLocaleNotDeployed
moClass: aaa:Locale
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/user-ext/locale-[name]

fltAaaUserRoleUserRoleNotDeployed

Fault Code: F1030

Message

For user: [name] role [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] role [name] can’t be assigned. Error: [configStatusMessage].

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported user role for ldap groups or local users.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the role is present.

Step 2blank.gif Verify that the role is applied.

Step 3blank.gif Verify that the role is compatible with locales assigned to ldap group or local user.

Fault Details

Severity: critical
Cause: user-role-config-error
mibFaultCode: 1030
mibFaultName: fltAaaUserRoleUserRoleNotDeployed
moClass: aaa:UserRole
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/ldap-ext/ldapgroup-[name]/role-[name]
Affected MO: sys/user-ext/remoteuser-[name]/role-[name]
Affected MO: sys/user-ext/user-[name]/role-[name]

fltAaaUserLocaleUserLocaleNotDeployed

Fault Code: F1031

Message

For user: [name] locale [name] can’t be assigned. Error: [configStatusMessage].For Ldap Group: [name] locale [name] can’t be assigned. Error: [configStatusMessage].

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported user locale for ldap groups or local users.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the locale is present.

Step 2blank.gif Verify that the locale is applied.

Step 3blank.gif Verify that the locale is compatible with roles assigned to ldap group or local user.

Fault Details

Severity: critical
Cause: user-locale-config-error
mibFaultCode: 1031
mibFaultName: fltAaaUserLocaleUserLocaleNotDeployed
moClass: aaa:UserLocale
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/ldap-ext/ldapgroup-[name]/locale-[name]
Affected MO: sys/user-ext/remoteuser-[name]/locale-[name]
Affected MO: sys/user-ext/user-[name]/locale-[name]

fltPkiKeyRingKeyRingNotDeployed

Fault Code: F1032

Message

Keyring [name] can’t be deployed. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an invalid Keyring.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the trust point configured for this keyring is present.

Step 2blank.gif Verify that the trust point found above is applied.

Fault Details

Severity: critical
Cause: keyring-config-error
mibFaultCode: 1032
mibFaultName: fltPkiKeyRingKeyRingNotDeployed
moClass: pki:KeyRing
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/pki-ext/keyring-[name]

fltCommSnmpSyscontactEmpty

Fault Code: F1033

Message

FPR Manager cannot deploy an empty value of SNMP Syscontact when Callhome is enabled. The previous value [sysContact] for SNMP Syscontact has been retained.

Explanation

This fault typically occurs when FPR Manager receives an invalid configuration from FPR Central wherein SNMP Syscontact is set to empty when Callhome is enabled.

Recommended Action

If you see this fault, please ensure that the SNMP Syscontact field on FPR Central is configured correctly for the domain group corresponding to this FPRM.

Fault Details

Severity: warning
Cause: snmp-config-error
mibFaultCode: 1033
mibFaultName: fltCommSnmpSyscontactEmpty
moClass: comm:Snmp
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/snmp-svc

fltCommDateTimeCommTimeZoneInvalid

Fault Code: F1034

Message

Timezone:[timezone] is invalid

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unsupported role.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that total number of roles is less than maximum supported roles.

Step 2blank.gif Verify that sum of privileges across all roles is less than maximum privileges sum.

Fault Details

Severity: minor
Cause: timezone-file-not-exists
mibFaultCode: 1034
mibFaultName: fltCommDateTimeCommTimeZoneInvalid
moClass: comm:DateTime
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/datetime-svc

fltAaaUserLocalUserNotDeployed

Fault Code: F1035

Message

Local User [name] can’t be deployed. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an invalid system user.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that local user name is not used by snmp users.

Fault Details

Severity: major
Cause: user-config-error
mibFaultCode: 1035
mibFaultName: fltAaaUserLocalUserNotDeployed
moClass: aaa:User
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/user-ext/user-[name]

fltCommSnmpUserSnmpUserNotDeployed

Fault Code: F1036

Message

SNMP User [name] can’t be deployed. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an invalid snmp user.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that snmp user name is not used by system users.

Fault Details

Severity: major
Cause: snmp-user-config-error
mibFaultCode: 1036
mibFaultName: fltCommSnmpUserSnmpUserNotDeployed
moClass: comm:SnmpUser
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/snmp-svc/snmpv3-user-[name]

fltCommSvcEpCommSvcNotDeployed

Fault Code: F1037

Message

Communication Service configuration can’t be deployed. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an invalid communication policy confiuration.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that ports configured across all communication services is unique.

Fault Details

Severity: major
Cause: comm-svc-config-error
mibFaultCode: 1037
mibFaultName: fltCommSvcEpCommSvcNotDeployed
moClass: comm:SvcEp
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext

fltSwVlanPortNsVLANCompNotSupport

Fault Code: F1056

Message

VLAN Port Count Optimization is not supported

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: no-vlan-optimization
mibFaultCode: 1056
mibFaultName: fltSwVlanPortNsVLANCompNotSupport
moClass: sw:VlanPortNs
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/vlan-port-ns

fltPolicyControlEpSuspendModeActive

Fault Code: F1057

Message

FPRM is suspended from receiving updates from FPR Central.

Explanation

This fault occurs when FPRM enters into suspend state from receiving updates from FPR Central that it is registered with.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Please check if FPR Central is restored to a previous version or a policy roll-back has occured. You may have brought FPR in to manual suspension mode by using set suspendstate on command under the system-control-ep policy scope.

Step 2blank.gif Please confirm the suspend state by using show control-ep policy detail under system scope. If you still want to receive the updates from FPR Central, you need to restore it back to a version compatible with FPRM or set the suspend state to off by acknowledging it by using set ackstate acked under policy-control scope.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: suspend-mode-entered
mibFaultCode: 1057
mibFaultName: fltPolicyControlEpSuspendModeActive
moClass: policy:ControlEp
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/control-ep-[type]

fltNetworkElementThermalThresholdCritical

Fault Code: F1080

Message

Fabric Interconnect [id] temperature: [thermal]

Explanation

This fault occurs when the temperature of a Fabric Interconnect exceeds a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the Fabric Interconnect.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the Fabric Interconnects have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 6blank.gif Replace faulty Fabric Interconnects.

Step 7blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 1080
mibFaultName: fltNetworkElementThermalThresholdCritical
moClass: network:Element
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]

fltFabricPinTargetDown

Fault Code: F1088

Message

Pin target is a non-existent interface

Explanation

This fault typically occurs when a PinGroup has an unresolvable target.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check whether the PinGroup target is correctly provisioned.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: invalid-target
mibFaultCode: 1088
mibFaultName: fltFabricPinTargetDown
moClass: fabric:PinTarget
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/lan-pin-group-[name]/target-[fabricId]
Affected MO: fabric/san/san-pin-group-[name]/target-[fabricId]

fltFabricEthLanEpOverlapping-vlan

Fault Code: F1090

Message

On Fabric: [switchId], Port: [slotId]/[aggrPortId]/[portId] following overlapping VLANs detected: [overlappingVlans]On Fabric: [switchId], Port: [slotId]/[portId] following overlapping VLANs detected: [overlappingVlans]

Explanation

This fault occurs when Overlapping Vlans occur due to mis configuration.

Recommended Action

Ports configured on Vlans belonging to a group should not intersect with other ports of different network group belonging to Vlans which overlap.

Fault Details

Severity: info
Cause: configuration-error
mibFaultCode: 1090
mibFaultName: fltFabricEthLanEpOverlappingVlan
moClass: fabric:EthLanEp
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]

fltFabricEthLanPcOverlapping-vlan

Fault Code: F1091

Message

Overlapping VLANs detected on Fabric: [switchId], Port: [portId] in configured VLANs: [overlappingVlans]

Explanation

This fault occurs when Overlapping Vlans occur due to mis configuration.

Recommended Action

Ports configured on Vlans belonging to a group should not intersect with other ports of different network group belonging to Vlans which overlap.

Fault Details

Severity: info
Cause: configuration-error
mibFaultCode: 1091
mibFaultName: fltFabricEthLanPcOverlappingVlan
moClass: fabric:EthLanPc
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/[id]/pc-[portId]

fltFabricVlanMisconfigured-mcast-policy

Fault Code: F1095

Message

VLAN [name] multicast policy [mcastPolicyName] is non-default.

Explanation

This fault is raised when VLAN belonging to a Springfield fabric has a non-default multicast policy assigned to it.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Un-assign multicast policy for the this vlan or change the multicast policy to default.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: vlan-mcast-policy-misconfigured
mibFaultCode: 1095
mibFaultName: fltFabricVlanMisconfiguredMcastPolicy
moClass: fabric:Vlan
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]

fltMgmtConnectionDisabled

Fault Code: F1097

Message

Management Connection [type] in server [id] is not operational

Explanation

This fault occurs when multiple management connections are acknowledegd.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Disable the management connection which is unused.

Step 2blank.gif If new management connection needs to be used, decommission and recommission server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: another-connection-already-enabled
mibFaultCode: 1097
mibFaultName: fltMgmtConnectionDisabled
moClass: mgmt:Connection
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]

fltMgmtConnectionUnused

Fault Code: F1098

Message

Management Connection [type] in server [id] is unused

Explanation

This fault occurs when a management connection is not enabel

Recommended Action

If you see this fault, you can enable the connection if none of the management connections are enabled. Else this can be ignored

Fault Details

Severity: info
Cause: connection-unused
mibFaultCode: 1098
mibFaultName: fltMgmtConnectionUnused
moClass: mgmt:Connection
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]

fltMgmtConnectionUnsupportedConnectivity

Fault Code: F1099

Message

Unsupported connectivity for management connection [type] in server [id]

Explanation

This fault typically occurs because Cisco FPR Manager has detected that the physical connectivity of the management port of the server is unsupported.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Connect the management port/s of the rack mount server to the Fabric Extender/s

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: unsupported-connectivity
mibFaultCode: 1099
mibFaultName: fltMgmtConnectionUnsupportedConnectivity
moClass: mgmt:Connection
Type: operational
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/rack-unit-[id]/mgmt/mgmt-connection-[type]
Affected MO: sys/switch-[id]/mgmt/mgmt-connection-[type]

fltCallhomeEpNoSnmpPolicyForCallhome

Fault Code: F1102

Message

FPR Manager cannot apply Callhome policy if SNMP Policy is not configured or if SNMP Syscontact has an empty value. The Callhome policy from FPR Central has not been applied.

Explanation

This fault typically occurs when FPR Manager receives an invalid configuration from FPR Central wherein Callhome is configured on FPR Central but there is no SNMP Syscontact defined locally.

Recommended Action

If you see this fault, please ensure that the SNMP Policy is configured on FPRM Manager, either locally or via FPR Central.

Fault Details

Severity: minor
Cause: callhome-config-error
mibFaultCode: 1102
mibFaultName: fltCallhomeEpNoSnmpPolicyForCallhome
moClass: callhome:Ep
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: call-home

fltCapabilityCatalogueLoadErrors

Fault Code: F1103

Message

Load errors: File parse errors: [fileParseFailures], provider load failures: [providerLoadFailures], XML element load errors: [loadErrors].

Explanation

The capability catalog failed to load fully. This may be caused by either a faulty FPRM image or a faulty catalog image.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the version of the capability catalog.

Step 2blank.gif Contact Cisco TAC to see if there are known issues with the catalog and if there is a catalog image that will fix the known issues.

Fault Details

Severity: major
Cause: load-catalog-failed
mibFaultCode: 1103
mibFaultName: fltCapabilityCatalogueLoadErrors
moClass: capability:Catalogue
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: capabilities

fltExtmgmtArpTargetsArpTargetsNotValid

Fault Code: F1114

Message

Invalid ARP Targets configured for Management Interface Polling. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an invalid ArpTargets Configuration.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that Arp target ip address and external management ip address are in the same subnet.

Step 2blank.gif Verify that Arp target ip address is not the same as ip address of this system’s fabric-interconnects.

Step 3blank.gif Verify that Arp target ip address is not the same as virtual IP Address.

Fault Details

Severity: major
Cause: arp-targets-config-error
mibFaultCode: 1114
mibFaultName: fltExtmgmtArpTargetsArpTargetsNotValid
moClass: extmgmt:ArpTargets
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/extmgmt-intf-monitor-policy/arp-target-policy

fltExtpolClientGracePeriodWarning

Fault Code: F1211

Message

FPR domain [name] registered with FPR Central has entered into the grace period.

Explanation

A FPR domain is registered with FPR Central without having a license. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under license scope from service-reg session.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: license-graceperiod-entered
mibFaultCode: 1211
mibFaultName: fltExtpolClientGracePeriodWarning
moClass: extpol:Client
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltExtpolClientGracePeriodWarning2

Fault Code: F1212

Message

FPR Domain [name] registered with FPR Central is running in the grace period for more than 10 days

Explanation

This FPR domain is registered with FPR Central without having a license. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: license-graceperiod-10days
mibFaultCode: 1212
mibFaultName: fltExtpolClientGracePeriodWarning2
moClass: extpol:Client
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltExtpolClientGracePeriodWarning3

Fault Code: F1213

Message

FPR Domain [name] registered with FPR Central is running in the grace period for more than 30 days

Explanation

This FPR Domain registered with FPR Central has been running in the grace period for more than 30 days. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 120 days.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Manager GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: license-graceperiod-30days
mibFaultCode: 1213
mibFaultName: fltExtpolClientGracePeriodWarning3
moClass: extpol:Client
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltExtpolClientGracePeriodWarning4

Fault Code: F1214

Message

FPR Domain [name] registered with FPR Central is running in the grace period for more than 60 days

Explanation

This FPR Domain registered with FPR Central has been running in the grace period for more than 60 days. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 60 days.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: license-graceperiod-60days
mibFaultCode: 1214
mibFaultName: fltExtpolClientGracePeriodWarning4
moClass: extpol:Client
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltExtpolClientGracePeriodWarning5

Fault Code: F1215

Message

FPR Domain [name] registered with FPR Central is running in the grace period for more than 90 days

Explanation

This FPR Domain registered with FPR Central has been running in the grace period for more than 90 days. This fault typically occurs if this FPR domains is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 90 days.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the number of licenses installed and consumed by FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for the FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: license-graceperiod-90days
mibFaultCode: 1215
mibFaultName: fltExtpolClientGracePeriodWarning5
moClass: extpol:Client
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltExtpolClientGracePeriodWarning6

Fault Code: F1216

Message

FPR Domain [name] registered with FPR Central is running in the grace period for more than 119 days

Explanation

This FPR Domain registered with FPR Central has been running in the grace period for more than 119 days. This fault typically occurs if this FPR domain is registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 119 days.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: license-graceperiod-119days
mibFaultCode: 1216
mibFaultName: fltExtpolClientGracePeriodWarning6
moClass: extpol:Client
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltExtpolClientGracePeriodWarning7

Fault Code: F1217

Message

Grace period for FPR Domain [name] registered with FPR Central has expired. Please acquire a license for the same.

Explanation

This FPR Domain registered with FPR Central has been running in the grace period for more than 120 days. FPR domains are registered with FPR Central after all default (and procured) licenses are assigned to other FPR domains and the unlicensed FPR Domains have been running for more than 120 days. At this stage, the system licensing state is set to expired.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the number of licenses installed and consumed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.

Step 2blank.gif Disable the unlicensed FPR Domains to bring the number of enabled Domains down to the number of total licenses.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC immediately to procure more licenses.

Fault Details

Severity: critical
Cause: license-graceperiod-expired
mibFaultCode: 1217
mibFaultName: fltExtpolClientGracePeriodWarning7
moClass: extpol:Client
Type: management
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltExtpolClientGracePeriodWarning1

Fault Code: F1218

Message

FPR Domain [name] is registered with FPR Central without a valid license.

Explanation

This FPR domain is registered with FPR Central without having a license. This fault typically occurs if this FPR domain is registered with FPR Central without the initial activation license and after all default licenses are assigned to other FPR domains.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check if the initial activation license is installed on FPR Central. In the Cisco FPR Central GUI, you can access the licensing information from the Operations Management tab for FPR Central. In the Cisco FPR Central CLI, you can access the licensing information by entering the show usage detail command under the license scope.

Step 2blank.gif Disable the unlicensed FPR Domains to bring the number of enabled Domains down to the number of total licenses.

Step 3blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC immediately to procure more licenses.

Fault Details

Severity: critical
Cause: license-insufficient
mibFaultCode: 1218
mibFaultName: fltExtpolClientGracePeriodWarning1
moClass: extpol:Client
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: extpol/reg/clients/client-[id]

fltStorageItemFilesystemIssues

Fault Code: F1219

Message

Partition [name] on fabric interconnect [id] has file system errors

Explanation

This fault occurs when the partition develops faults

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: equipment-degraded
mibFaultCode: 1219
mibFaultName: fltStorageItemFilesystemIssues
moClass: storage:Item
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/stor-part-[name]

fltPkiKeyRingModulus

Fault Code: F1222

Message

[name] Keyring’s RSA modulus is invalid.

Explanation

This fault occurs when RSA keyring is created without modulus set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: invalid-keyring-modulus
mibFaultCode: 1222
mibFaultName: fltPkiKeyRingModulus
moClass: pki:KeyRing
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/pki-ext/keyring-[name]

fltAaaOrgLocaleOrgNotPresent

Fault Code: F1223

Message

Locale Org [name] can’t be deployed. Error: [configStatusMessage]

Explanation

This fault typically occurs because Cisco FPR Manager has detected an unidentified org reference.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the org dn referenced in this Org is exists, if not create the same.

Fault Details

Severity: warning
Cause: locale-org-config-error
mibFaultCode: 1223
mibFaultName: fltAaaOrgLocaleOrgNotPresent
moClass: aaa:Org
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/user-ext/locale-[name]/org-[name]

fltNetworkOperLevelExtraprimaryvlans

Fault Code: F1229

Message

Fabric Interconnect [id]: Number of primary vlans exceeds the max limit on the FI: Number of Primary Vlans: [primaryVlanCount] and Max primary vlans allowed: [maxPrimaryVlanCount]

Explanation

This fault occurs when the fabric interconnect has more number of primary vlans than what is supported.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif It is recommended that operator should delete the extra primary vlans than are there in the FI. System may appear to be normally functioning even with these extra primary vlans in place. However there may be performance issues observed as the system is operating above the recommended scale limits..

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: extra-primary-vlans
mibFaultCode: 1229
mibFaultName: fltNetworkOperLevelExtraprimaryvlans
moClass: network:OperLevel
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/oper-level

fltEquipmentHealthLedCriticalError

Fault Code: F1236

Message

Health LED of server [chassisId]/[slotId] shows error. Reason: [healthLedStateQualifier]Health LED of server [id] shows error. Reason: [healthLedStateQualifier]

Explanation

This fault is raised Blade LED changes to amber blinking

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Read fault summary and determine course of action.

Fault Details

Severity: critical
Cause: health-led-amber-blinking
mibFaultCode: 1236
mibFaultName: fltEquipmentHealthLedCriticalError
moClass: equipment:HealthLed
Type: equipment
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led

fltEquipmentHealthLedMinorError

Fault Code: F1237

Message

Health LED of server [chassisId]/[slotId] shows error. Reason: [healthLedStateQualifier]Health LED of server [id] shows error. Reason: [healthLedStateQualifier]

Explanation

This fault is raised Blade LED changes to amber

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Read fault summary and determine course of action.

Fault Details

Severity: minor
Cause: health-led-amber
mibFaultCode: 1237
mibFaultName: fltEquipmentHealthLedMinorError
moClass: equipment:HealthLed
Type: equipment
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/health-led
Affected MO: sys/chassis-[id]/blade-[slotId]/health-led
Affected MO: sys/chassis-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/chassis-[id]/health-led
Affected MO: sys/chassis-[id]/psu-[id]/health-led
Affected MO: sys/chassis-[id]/slot-[id]/health-led
Affected MO: sys/fex-[id]/health-led
Affected MO: sys/fex-[id]/psu-[id]/health-led
Affected MO: sys/fex-[id]/slot-[id]/health-led
Affected MO: sys/rack-unit-[id]/ext-board-[id]/health-led
Affected MO: sys/rack-unit-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/rack-unit-[id]/health-led
Affected MO: sys/rack-unit-[id]/psu-[id]/health-led
Affected MO: sys/switch-[id]/fan-module-[tray]-[id]/health-led
Affected MO: sys/switch-[id]/psu-[id]/health-led

fltVnicEtherIfRemoteVlanUnresolvable

Fault Code: F1249

Message

The named vlan [name] for vNIC [name] cannot be resolved remotely

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: referenced-remote-vlan-unresolvable
mibFaultCode: 1249
mibFaultName: fltVnicEtherIfRemoteVlanUnresolvable
moClass: vnic:EtherIf
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/network-sets/fabric-network-[name]/fabric-network-def-[name]/vm-network-def-[name]/if-[name]
Affected MO: fabric/lan/profiles/vnic-[name]/if-[name]
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/lan-conn-templ-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/ls-[name]/ipc-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/if-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ipc-[name]/if-[name]

fltVnicEtherVirtualization-conflict

Fault Code: F1251

Message

Multiple connection policies cannot be assigned to the same Eth vNIC

Explanation

This fault occurs when multiple connection policies are assigned to the same vNIC.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check on the vNIC if different types of connection policies (dynamic/VMQ) are assigned. Keep only one type.

Step 2blank.gif Check on the vNIC through CLI if more than one connection policy of the same type is assigned. Keep only one connection policy.

Fault Details

Severity: major
Cause: multiple-connection-policies
mibFaultCode: 1251
mibFaultName: fltVnicEtherVirtualizationConflict
moClass: vnic:Ether
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]

fltLsIssuesIscsi-config-failed

Fault Code: F1252

Message

Service Profile [name] configuration failed due to iSCSI issue [iscsiConfigIssues]

Explanation

This fault typically occurs when Cisco FPR Manager Service Profile configuration failed due to iSCSI Config Issues.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Correct the Service Profile iSCSI Configuration as per the issue reported.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: configuration-failed
mibFaultCode: 1252
mibFaultName: fltLsIssuesIscsiConfigFailed
moClass: ls:Issues
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue

fltStorageLocalDiskMissing

Fault Code: F1256

Message

Local disk [id] missing on server [chassisId]/[slotId]Local disk [id] missing on server [id]

Explanation

This fault occurs when a disk is missing.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Insert the disk.

Fault Details

Severity: major
Cause: equipment-missing
mibFaultCode: 1256
mibFaultName: fltStorageLocalDiskMissing
moClass: storage:LocalDisk
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]

fltStorageFlexFlashControllerInoperable

Fault Code: F1257

Message

FlexFlash Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]

Explanation

This fault occurs when the flexflash controller is inaccessible.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif If reported as Firmware Mismatch, update the CIMC and Board Controller firmware

Step 2blank.gif If reported as Fatal Error, reset the CIMC and update Board Controller firmware

Step 3blank.gif For PCI and mezz-based controllers, check the seating of the storage controller. If the problem persists, replace the controller

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 1257
mibFaultName: fltStorageFlexFlashControllerInoperable
moClass: storage:FlexFlashController
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]

fltStorageFlexFlashCardInoperable

Fault Code: F1258

Message

FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason]FlexFlash Card [slotNumber] on server [id] is inoperable. Reason: [operQualifierReason]

Explanation

This fault occurs when the flexflash card is inaccessible.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif If reported as Write Protected, then remove write protection from the card

Step 2blank.gif If reported as Invalid Capacity, use an OS disk utility to delete/recreate the partitions

Step 3blank.gif If the above action did not resolve the issue, replace the card

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 1258
mibFaultName: fltStorageFlexFlashCardInoperable
moClass: storage:FlexFlashCard
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]

fltStorageFlexFlashCardMissing

Fault Code: F1259

Message

FlexFlash Card [slotNumber] missing on server [chassisId]/[slotId]FlexFlash Card [slotNumber] missing on server [id]

Explanation

This fault occurs when a FlexFlash Card is missing.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Insert the Card.

Fault Details

Severity: info
Cause: equipment-missing
mibFaultCode: 1259
mibFaultName: fltStorageFlexFlashCardMissing
moClass: storage:FlexFlashCard
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]

fltStorageFlexFlashVirtualDriveDegraded

Fault Code: F1260

Message

FlexFlash Virtual Drive RAID degraded on server [chassisId]/[slotId]. Reason: [raidState]FlexFlash Virtual Drive RAID degraded on server [id]. Reason: [raidState]

Explanation

This fault occurs when the flexflash raid is degraded.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)

Step 2blank.gif Verify the health of the controller/card(s). If the above action did not resolve the issue, replace the card(s)

Fault Details

Severity: minor
Cause: equipment-degraded
mibFaultCode: 1260
mibFaultName: fltStorageFlexFlashVirtualDriveDegraded
moClass: storage:FlexFlashVirtualDrive
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]

fltStorageFlexFlashVirtualDriveInoperable

Fault Code: F1261

Message

FlexFlash Virtual Drive on server [chassisId]/[slotId] is inoperable. Reason: [raidState]FlexFlash Virtual Drive on server [id] is inoperable. Reason: [raidState]

Explanation

This fault occurs when the flexflash virtual drive is inoperable.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)

Step 2blank.gif Verify the health of the controller/card(s). If the above action did not resolve the issue, replace the card(s)

Fault Details

Severity: major
Cause: equipment-inoperable
mibFaultCode: 1261
mibFaultName: fltStorageFlexFlashVirtualDriveInoperable
moClass: storage:FlexFlashVirtualDrive
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/vd-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/vd-[id]

fltAaaProviderGroupProvidergroupsize

Fault Code: F1279

Message

For [dn]: Server Group [name] has [size] provider references. Authentication might fail, if this provider group is used with auth-domain.

Explanation

This fault typically occurs because Cisco FPR Manager has detected provider-group with 0 provider references..

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Need to delete the provider group which does not have any provider references.

Step 2blank.gif Or Add provider references to provider group.

Fault Details

Severity: warning
Cause: provider-group-size-empty
mibFaultCode: 1279
mibFaultName: fltAaaProviderGroupProvidergroupsize
moClass: aaa:ProviderGroup
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/ldap-ext/providergroup-[name]
Affected MO: sys/radius-ext/providergroup-[name]
Affected MO: sys/tacacs-ext/providergroup-[name]

fltFirmwareAutoSyncPolicyDefaultHostPackageMissing

Fault Code: F1284

Message

Default host firmware package is missing or deleted.

Explanation

This fault typically occurs for the following reasons: when Auto Firmware Sync Policy is set Auto-acknowledge or User-acknowledge and default host firmware pack is not available.

  • Auto Firmware Sync is not happening.
  • Default host firmware package is missing or deleted.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Go to Servers tab and expand policies node. Select Host Firmware Packages under policies node.

Step 2blank.gif If the FSM failed, review the error message in the FSM.

Step 3blank.gif Create a host firmware package with name ’default’. If the problem persists, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: default-hostpack-missing
mibFaultCode: 1284
mibFaultName: fltFirmwareAutoSyncPolicyDefaultHostPackageMissing
moClass: firmware:AutoSyncPolicy
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/fw-auto-sync

fltFabricPooledVlanNamedVlanUnresolved

Fault Code: F1306

Message

VLAN [name] for VLAN group [name] cannot be resolved to any existing vlans.

Explanation

This fault typically occurs when a named VLAN in VLAN group cannot be resolved to any existing vlans.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Create VLAN.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: named-vlan-unresolved
mibFaultCode: 1306
mibFaultName: fltFabricPooledVlanNamedVlanUnresolved
moClass: fabric:PooledVlan
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/[id]/net-group-[name]/net-[name]
Affected MO: fabric/lan/net-group-[name]/net-[name]

fltExtvmmVMNDRefVmNetworkReferenceIncorrect

Fault Code: F1320

Message

VM Network [name] references [vmNetworkDefName] that is already being referenced by another VM Network

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: vm-network-reference-incorrect
mibFaultCode: 1320
mibFaultName: fltExtvmmVMNDRefVmNetworkReferenceIncorrect
moClass: extvmm:VMNDRef
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/vm-network-sets/vm-network-[name]/vm-network-def-ref[name]

fltExtmgmtNdiscTargetsNdiscTargetsNotValid

Fault Code: F1321

Message

Invalid NDISC Targets configured for Management Interface Polling. Error: [configStatusMessage]

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: ndisc-targets-config-error
mibFaultCode: 1321
mibFaultName: fltExtmgmtNdiscTargetsNdiscTargetsNotValid
moClass: extmgmt:NdiscTargets
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/extmgmt-intf-monitor-policy/ndisc-target-policy

fltFirmwareBootUnitPowerCycleRequired

Fault Code: F1325

Message

Board controller upgraded, manual a/c power cycle required on server [serverId]

Explanation

None set.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Power cycle the board controller.

Fault Details

Severity: critical
Cause: board-ctrl-upgraded
mibFaultCode: 1325
mibFaultName: fltFirmwareBootUnitPowerCycleRequired
moClass: firmware:BootUnit
Type: generic
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: capabilities/ep/mgmt-ext/fw-boot-def/bootunit-[type]
Affected MO: capabilities/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/fpga/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/rommon/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/mgmt/fw-boot-def/bootunit-[type]
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-boot-def/bootunit-[type]
Affected MO: sys/switch-[id]/mgmt/fw-boot-def/bootunit-[type]

fltMgmtControllerUnsupportedDimmBlacklisting

Fault Code: F1328

Message

Dimm blacklisting is not supported on server [chassisId]/[slotId]Dimm blacklisting is not supported on server [id]

Explanation

This fault typically occurs when the CIMC firmware on a server is an earlier release than Cisco FPR, Release 2.2.

Recommended Action

If you see this fault, consider upgrading the CIMC firmware, and the entire Cisco FPR instance if necessary, to Cisco FPR, Release 2.2 or later.

Fault Details

Severity: info
Cause: incompatible-server-firmware
mibFaultCode: 1328
mibFaultName: fltMgmtControllerUnsupportedDimmBlacklisting
moClass: mgmt:Controller
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt
Affected MO: sys/chassis-[id]/slot-[id]/mgmt
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt
Affected MO: sys/fex-[id]/mgmt
Affected MO: sys/fex-[id]/slot-[id]/mgmt
Affected MO: sys/mgmt
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt
Affected MO: sys/rack-unit-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt
Affected MO: sys/rack-unit-[id]/mgmt
Affected MO: sys/switch-[id]/mgmt

fltFabricEthLanEpUdldLinkDown

Fault Code: F1358

Message

UDLD state for ether port [slotId]/[aggrPortId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].

Explanation

This fault occurs when an ethernet uplink port is unidirectional connected.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the tx and rx connection of the uplink port.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: udld-link-down
mibFaultCode: 1358
mibFaultName: fltFabricEthLanEpUdldLinkDown
moClass: fabric:EthLanEp
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/phys-slot-[slotId]-port-[portId]

fltFabricEthLanPcEpUdldLinkDown

Fault Code: F1359

Message

UDLD state for ether port [slotId]/[aggrPortId]/[portId] on fabric interconnect [switchId] is: [udldOperState].UDLD state for ether port [slotId]/[portId] on fabric interconnect [switchId] is: [udldOperState].

Explanation

This fault occurs when an ethernet uplink port-channel member is unidirectional connected.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the tx and rx connection of the uplink port.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: udld-link-down
mibFaultCode: 1359
mibFaultName: fltFabricEthLanPcEpUdldLinkDown
moClass: fabric:EthLanPcEp
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/eth-estc/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lan/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/lanmon/[id]/eth-mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/fcoesanpc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/san/[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/pc-[portId]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]
Affected MO: fabric/server/sw-[id]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]-port-[portId]

fltEquipmentChassisInvalid-fru

Fault Code: F1407

Message

Chassis [id] has a empty value for FRU identity reported by CMC.

Explanation

This fault typically occurs when the FRU information for a chassis has empty value.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fru-problem
mibFaultCode: 1407
mibFaultName: fltEquipmentChassisInvalidFru
moClass: equipment:Chassis
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]

fltEquipmentSwitchIOCardRemoved

Fault Code: F1408

Message

[side] FI IOM [chassisId]/[id] ([switchId]) is removed

Explanation

This fault typically occurs because an FI I/O module is removed from the chassis. In a cluster configuration, the chassis fails over to the other FI I/O module. For a standalone configuration, the chassis associated with the FI I/O module loses network connectivity. This is a critical fault because it can result in the loss of network connectivity and disrupt data traffic through the FI I/O module.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reinsert the FI I/O module and configure the fabric-interconnect ports connected to it as server ports and wait a few minutes to see if the fault clears.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-removed
mibFaultCode: 1408
mibFaultName: fltEquipmentSwitchIOCardRemoved
moClass: equipment:SwitchIOCard
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/sw-slot-[id]

fltEquipmentSwitchIOCardThermalProblem

Fault Code: F1409

Message

[side] FI IOM [chassisId]/[id] ([switchId]) operState: [operState]

Explanation

This fault occurs when there is a thermal problem on an FI I/O module. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the FI I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the FI I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace faulty FI I/O modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 1409
mibFaultName: fltEquipmentSwitchIOCardThermalProblem
moClass: equipment:SwitchIOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/sw-slot-[id]

fltEquipmentSwitchIOCardThermalThresholdNonCritical

Fault Code: F1410

Message

[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]

Explanation

This fault occurs when the temperature of an FI I/O module has exceeded a non-critical threshold value, but is still below the critical threshold. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the FI I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 8blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: thermal-problem
mibFaultCode: 1410
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdNonCritical
moClass: equipment:SwitchIOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/sw-slot-[id]

fltEquipmentSwitchIOCardThermalThresholdCritical

Fault Code: F1411

Message

[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]

Explanation

This fault occurs when the temperature of an FI I/O module has exceeded a critical threshold value. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the FI I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace the faulty FI I/O modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 1411
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdCritical
moClass: equipment:SwitchIOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/sw-slot-[id]

fltEquipmentSwitchIOCardThermalThresholdNonRecoverable

Fault Code: F1412

Message

[side] FI IOM [chassisId]/[id] ([switchId]) temperature: [thermal]

Explanation

This fault occurs when the temperature of an FI I/O module has been out of the operating range, and the issue is not recoverable. Be aware of the following possible contributing factors:

  • Temperature extremes can cause Cisco FPR equipment to operate at reduced efficiency and cause a variety of problems, including early degradation, failure of chips, and failure of equipment. In addition, extreme temperature fluctuations can cause CPUs to become loose in their sockets.
  • Cisco FPR equipment should operate in an environment that provides an inlet air temperature not colder than 50F (10C) nor hotter than 95F (35C).
  • If sensors on a CPU reach 179.6F (82C), the system will take that CPU offline.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the FI I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace the faulty FI I/O modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 1412
mibFaultName: fltEquipmentSwitchIOCardThermalThresholdNonRecoverable
moClass: equipment:SwitchIOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/sw-slot-[id]

fltEquipmentSwitchIOCardIdentity

Fault Code: F1414

Message

[side] FI IOM [chassisId]/[id] ([switchId]) has a malformed FRU

Explanation

This fault typically occurs when the FRU information for an FI I/O module is corrupted or malformed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the capability catalog in Cisco FPR Manager is up to date. If necessary, update the catalog.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fru-problem
mibFaultCode: 1414
mibFaultName: fltEquipmentSwitchIOCardIdentity
moClass: equipment:SwitchIOCard
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/sw-slot-[id]

fltEquipmentSwitchIOCardCpuThermalThresholdCritical

Fault Code: F1415

Message

[side] FI IOM [chassisId]/[id] ([switchId]) processor temperature exceeded the limit

Explanation

This fault typically occurs when the processor temperature in FI-IOM exceeds the limit.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Review the product specifications to determine the temperature operating range of the FI I/O module.

Step 2blank.gif Review the Cisco FPR Site Preparation Guide to ensure the chassis and FI I/O modules have adequate airflow, including front and back clearance.

Step 3blank.gif Verify that the air flows on the Cisco FPR chassis and FI I/O module are not obstructed.

Step 4blank.gif Verify that the site cooling system is operating properly.

Step 5blank.gif Power off unused blade servers and rack servers.

Step 6blank.gif Clean the installation site at regular intervals to avoid buildup of dust and debris, which can cause a system to overheat.

Step 7blank.gif Replace the faulty FI I/O modules.

Step 8blank.gif Use the Cisco FPR power capping capability to limit power usage. Power capping can limit the power consumption of the system, including blade and rack servers, to a threshold that is less than or equal to the system’s maximum rated power. Power-capping can have an impact on heat dissipation and help to lower the installation site temperature.

Step 9blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: thermal-problem
mibFaultCode: 1415
mibFaultName: fltEquipmentSwitchIOCardCpuThermalThresholdCritical
moClass: equipment:SwitchIOCard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/sw-slot-[id]

fltPowerBudgetChassisPsuMixedMode

Fault Code: F1421

Message

Chassis [id] has a mix of high-line and low-line PSU input power sources.

Explanation

This fault occurs when there is a mix of high-line and low-line PSU input power source.

Recommended Action

If you see this fault, change all the PSU input power sources to have same mode

Fault Details

Severity: critical
Cause: psu-mixed-mode
mibFaultCode: 1421
mibFaultName: fltPowerBudgetChassisPsuMixedMode
moClass: power:Budget
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/budget
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/budget
Affected MO: sys/chassis-[id]/budget
Affected MO: sys/rack-unit-[id]/budget
Affected MO: sys/rack-unit-[id]/ext-board-[id]/budget

fltNetworkElementRemoved

Fault Code: F1426

Message

Fabric Interconnect [id] operability: [operability]

Explanation

This fault occurs when the fabric interconnect is removed in a clustering setup.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reinsert the removed fabric interconnect back into the chassis (applicable to FPR-Mini only).

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: equipment-removed
mibFaultCode: 1426
mibFaultName: fltNetworkElementRemoved
moClass: network:Element
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]

fltNetworkOperLevelExtrasecondaryvlans

Fault Code: F1432

Message

Fabric Interconnect [id]: Number of secondary vlans exceeds the max limit on the FI: Number of secondary vlans: [secondaryVlanCount] and Max secondary vlans allowed: [maxSecondaryVlanCount]

Explanation

This fault occurs when the fabric interconnect has more number of secondary vlans than what is supported.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif It is recommended that operator should delete the extra secondary vlans that are there in the FI. System may appear to be normally functioning even with these extra secondary vlans in place. However there may be performance issues observed as the system is operating above the recommended scale limits..

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: extra-secondary-vlans
mibFaultCode: 1432
mibFaultName: fltNetworkOperLevelExtrasecondaryvlans
moClass: network:OperLevel
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/oper-level

fltSwVlanExtrasecondaryvlansperprimary

Fault Code: F1433

Message

Number of secondary vlans associated with the primary vlan [id] in Fabric Interconnect [switchId] exceeds the max limit: Number of secondary vlans: [secVlanPerPrimaryVlanCount] and Max secondary vlans allowed in a primary vlan: 30

Explanation

This fault occurs when the fabric interconnect has more number of secondary vlans per primary vlan than what is supported.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif It is recommended that operator should delete the extra secondary vlans on this primary vlan that are there in the FI. System may appear to be normally functioning even with these extra secondary vlans on this primary vlan in place. However there may be performance issues observed as the system is operating above the recommended scale limits..

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: extra-secondary-vlans-per-primary
mibFaultCode: 1433
mibFaultName: fltSwVlanExtrasecondaryvlansperprimary
moClass: sw:Vlan
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/lan/profiles/vnic-[name]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/rack-unit-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/access-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-eth/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/fcoesan-pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/border-fc/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/pc-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/lanmon-eth/mon-[name]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/path-[id]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/mgmt/fabric-[switchId]/vc-[id]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/phys/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/switch-[id]/ssp-lanmon-eth/ssp-mon-session[name]/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/pc-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/ethestc-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/slot-[slotId]-aggr-port-[aggrPortId]/fcoesan-ep-slot-[slotId]port-[portId]/vlan-[id]
Affected MO: sys/tbh/border-eth/vlan-[id]

fltMgmtBackupPolicyConfigConfiguration backup outdated

Fault Code: F1437

Message

Config backup may be outdated

Explanation

This fault occurs when last backup configuration is taken long back

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Please take a configuration backup

Fault Details

Severity: minor
Cause: config-backup-outdated
mibFaultCode: 1437
mibFaultName: fltMgmtBackupPolicyConfigConfigurationBackupOutdated
moClass: mgmt:BackupPolicyConfig
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/bkup-policy-cfg

fltFirmwareStatusCimcFirmwareMismatch

Fault Code: F1441

Message

Aggregate blade CIMC firmware mismatch. Firmware: [cimcVersion]

Explanation

This fault typically occurs when the CIMC firmware image on master and slave node in an aggregate blade does not match.

Recommended Action

Update and activate master and slave CIMC to same firmware version.

Fault Details

Severity: critical
Cause: cimc-firmware-mismatch
mibFaultCode: 1441
mibFaultName: fltFirmwareStatusCimcFirmwareMismatch
moClass: firmware:Status
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status

fltFirmwareStatusPldFirmwareMismatch

Fault Code: F1442

Message

Aggregate blade board controller firmware mismatch. Firmware: [pldVersion]

Explanation

This fault typically occurs when the board controller firmware image on master and slave node in an aggregate blade does not match.

Recommended Action

Update master and slave board controller to same firmware version.

Fault Details

Severity: critical
Cause: pld-firmware-mismatch
mibFaultCode: 1442
mibFaultName: fltFirmwareStatusPldFirmwareMismatch
moClass: firmware:Status
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/fw-status
Affected MO: sys/chassis-[id]/slot-[id]/fw-status
Affected MO: sys/fex-[id]/slot-[id]/fw-status
Affected MO: sys/fw-status
Affected MO: sys/rack-unit-[id]/fw-status
Affected MO: sys/switch-[id]/fw-status

fltVnicEtherVirtualization-netflow-conflict

Fault Code: F1443

Message

Netflow and VMQ/SRIOV-USNIC policies cannot be assigned to the same Eth vNIC

Explanation

This fault typically occurs when a netflow src vnic is made a USNIC or VMQ vnic

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove the vnic from a netflow session or remove the usnic/vmq policy

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: multiple-connection-policies
mibFaultCode: 1443
mibFaultName: fltVnicEtherVirtualizationNetflowConflict
moClass: vnic:Ether
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/lan-conn-pol-[name]/ether-[name]
Affected MO: org-[name]/ls-[name]/ether-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]/ether-[name]

fltSysdebugLogExportStatusLogExportFailure

Fault Code: F1444

Message

Log export to remote server failed from [switchId]:[exportFailureReason]

Explanation

This fault occurs when Cisco Firepower Manager cannot transfer a log file to a remote server. This is typically the result of one of the following issues:

  • The remote server is not accessible.
  • One or more of the parameters for the remote server that are specified for the log export target, such as path, username, password, ssh-key and server name, are incorrect.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify the connectivity to the remote server.

Step 2blank.gif Verify the path information of the remote server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: server-error
mibFaultCode: 1444
mibFaultName: fltSysdebugLogExportStatusLogExportFailure
moClass: sysdebug:LogExportStatus
Type: sysdebug
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/sysdebug/log-export-policy/log-export-status-[switchId]

fltLsServerSvnicNotPresent

Fault Code: F1459

Message

Service profile [name] does not contain service vnics for netflow.

Explanation

The service profile does not have service vnics, hence netflow will not function on this server. This fault typically occurs as a result of one of the following issues:

  • Service profile has maximum number of vnics already created, hence cannot accomodate service vnics required for netflow.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If you have already enabled netflow, please reduce the number of vnics on the SP to accomodate service vnics.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: warning
Cause: svnic-not-present
mibFaultCode: 1459
mibFaultName: fltLsServerSvnicNotPresent
moClass: ls:Server
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]
Affected MO: org-[name]/tier-[name]/ls-[name]

fltLsIssuesKvmPolicyUnsupported

Fault Code: F1460

Message

Kvm mgmt policy not supported by current CIMC version

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: unsupported-cimc-firmware
mibFaultCode: 1460
mibFaultName: fltLsIssuesKvmPolicyUnsupported
moClass: ls:Issues
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/config-issue
Affected MO: org-[name]/tier-[name]/ls-[name]/config-issue

fltComputeABoardThermalProblem

Fault Code: F1461

Message

Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) thermal: [thermal]Motherboard of server [id] (service profile: [assignedToDn]) thermal: [thermal]

Explanation

This fault typically occurs when the motherboard thermal sensors on a server detect a problem.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the server fans are working properly.

Step 2blank.gif Wait for 24 hours to see if the problem resolves itself.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: thermal-problem
mibFaultCode: 1461
mibFaultName: fltComputeABoardThermalProblem
moClass: compute:ABoard
Type: environmental
Callhome: environmental
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]

fltComputeABoardPowerUsageProblem

Fault Code: F1462

Message

Motherboard [faultQualifier] of server [chassisId]/[slotId] (service profile: [assignedToDn]) powerUsage: [powerUsage]Motherboard of server [id] (service profile: [assignedToDn]) powerUsage: [powerUsage]

Explanation

This fault typically occurs when the motherboard power consumption exceeds certain threshold limits. At that time the power usage sensors on a server detect a problem.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: power-problem
mibFaultCode: 1462
mibFaultName: fltComputeABoardPowerUsageProblem
moClass: compute:ABoard
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]

fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable

Fault Code: F1463

Message

Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]

Explanation

This fault is raised when one or more motherboard input voltages has become too high and is unlikely to recover.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: voltage-problem
mibFaultCode: 1463
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdUpperNonRecoverable
moClass: compute:ABoard
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]

fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable

Fault Code: F1464

Message

Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]

Explanation

This fault is raised when one or more motherboard input voltages has dropped too low and is unlikely to recover.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: voltage-problem
mibFaultCode: 1464
mibFaultName: fltComputeABoardMotherBoardVoltageThresholdLowerNonRecoverable
moClass: compute:ABoard
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]

fltComputeABoardMotherBoardVoltageUpperThresholdCritical

Fault Code: F1465

Message

Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]

Explanation

This fault is raised when one or more motherboard input voltages has crossed upper critical thresholds.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: voltage-problem
mibFaultCode: 1465
mibFaultName: fltComputeABoardMotherBoardVoltageUpperThresholdCritical
moClass: compute:ABoard
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]

fltComputeABoardMotherBoardVoltageLowerThresholdCritical

Fault Code: F1466

Message

Motherboard input voltage(12V/5V/3V) in server [id] is [voltage]Motherboard [faultQualifier] input voltage(12V/5V/3V) in server [chassisId]/[slotId] is [voltage]

Explanation

This fault is raised when one or more motherboard input voltages has crossed lower critical thresholds.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: voltage-problem
mibFaultCode: 1466
mibFaultName: fltComputeABoardMotherBoardVoltageLowerThresholdCritical
moClass: compute:ABoard
Type: environmental
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]
Affected MO: sys/rack-unit-[id]/board
Affected MO: sys/rack-unit-[id]/ext-board-[id]

fltCimcvmediaActualMountEntryVmediaMountFailed

Fault Code: F1467

Message

Server [chassisId]/[slotId] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.Server [id] (service profile: [assignedToDn]) vmedia mapping [mappingName] has failed.

Explanation

None set.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Check the mount related details(remote server ip, port, path & file is reachable) and reack the server.

Fault Details

Severity: major
Cause: vmedia-mount-inaccessible
mibFaultCode: 1467
mibFaultName: fltCimcvmediaActualMountEntryVmediaMountFailed
moClass: cimcvmedia:ActualMountEntry
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/rack-unit-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]
Affected MO: sys/switch-[id]/mgmt/actual-mount-list/actual-mount-entry-[virtualDiskId]

fltFabricVlanPrimaryVlanMissingForIsolated

Fault Code: F1468

Message

Primary Vlan can not be resolved for isolated vlan [name]

Explanation

This fault typically occurs when Cisco FPR Manager encounters a problem resolving the primary VLAN ID corresponding to a particular isolated VLAN.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Associate the isolated VLAN with a valid primary VLAN.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: primary-vlan-missing-for-isolated
mibFaultCode: 1468
mibFaultName: fltFabricVlanPrimaryVlanMissingForIsolated
moClass: fabric:Vlan
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]

fltFabricVlanPrimaryVlanMissingForCommunity

Fault Code: F1469

Message

Primary Vlan can not be resolved for community vlan [name]

Explanation

This fault typically occurs when Cisco FPR Manager encounters a problem resolving the primary VLAN ID corresponding to a particular community VLAN.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Associate the community VLAN with a valid primary VLAN.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: minor
Cause: primary-vlan-missing-for-community
mibFaultCode: 1469
mibFaultName: fltFabricVlanPrimaryVlanMissingForCommunity
moClass: fabric:Vlan
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]

fltFabricVlanMismatch-a

Fault Code: F1470

Message

VLAN [name] has [overlapStateForA] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect A

Explanation

This fault typically occurs when private vlan properties of VLAN under one cloud conflicts with the private vlan properties of VLAN under another cloud for the fabric interconnect A. The cloud here means either a LAN cloud or an appliance cloud. This issue can stop the usage of this vlan.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the sharing property of the VLAN under both clouds and fabric A referred by its VLAN ID.

Step 2blank.gif If the sharing property of the VLAN does not match with the VLAN on the other cloud, then change the sharing property of either of the VLANs, so that it matches with each other.

Step 3blank.gif If the VLAN is a isolated/community vlan, check the pubnwname property of the VLAN under both clouds referred by its VLAN ID.

Step 4blank.gif If the pubnwname property of the isolated/community VLAN does not match with the isolated/community VLAN on the other cloud, then change the pubnwname property of either of the VLANs, so that it matches with each other.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: vlan-mismatch
mibFaultCode: 1470
mibFaultName: fltFabricVlanMismatchA
moClass: fabric:Vlan
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]

fltFabricVlanMismatch-b

Fault Code: F1471

Message

VLAN [name] has [overlapStateForB] with another vlan under lan-cloud/appliance-cloud for the fabric interconnect B

Explanation

This fault typically occurs when private vlan properties of VLAN under one cloud conflicts with the private vlan properties of VLAN under another cloud for the fabric interconnect B. The cloud here means either a LAN cloud or an appliance cloud. This issue can stop the usage of this vlan.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the sharing property of the VLAN under both clouds and fabric B referred by its VLAN ID.

Step 2blank.gif If the sharing property of the VLAN does not match with the VLAN on the other cloud, then change the sharing property of either of the VLANs, so that it matches with each other.

Step 3blank.gif If the VLAN is a isolated/community vlan, check the pubnwname property of the VLAN under both clouds referred by its VLAN ID.

Step 4blank.gif If the pubnwname property of the isolated/community VLAN does not match with the isolated/community VLAN on the other cloud, then change the pubnwname property of either of the VLANs, so that it matches with each other.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: vlan-mismatch
mibFaultCode: 1471
mibFaultName: fltFabricVlanMismatchB
moClass: fabric:Vlan
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]

fltFabricVlanErrorAssocPrimary

Fault Code: F1472

Message

VLAN [name] is in error state because the associated primary vlan [assocPrimaryVlanState]

Explanation

This fault typically occurs when there is an error in associated primary vlan of a secondary VLAN. This issue can stop the usage of this vlan.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Check the pubnwname property of the VLAN.

Step 2blank.gif If the pubnwname is not given or refers to a non-existing primary vlan, give a name of a primary vlan which is in good state.

Step 3blank.gif If the pubnwname refers to a vlan which is not a primary vlan, then either change the referred vlan to be a primary vlan or give a different primary vlan.

Step 4blank.gif If the pubnwname refers to a valid primary vlan, then check the state of the primary VLAN.

Step 5blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: vlan-error-assoc-primary
mibFaultCode: 1472
mibFaultName: fltFabricVlanErrorAssocPrimary
moClass: fabric:Vlan
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/eth-estc/[id]/net-[name]
Affected MO: fabric/eth-estc/net-[name]
Affected MO: fabric/lan/[id]/net-[name]
Affected MO: fabric/lan/net-[name]

fltStorageMezzFlashLifeConfiguration-error

Fault Code: F1494

Message

Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]

Explanation

This fault occurs when FPRM is not able to retrieve the Fusion-io life left due to an error.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Upgrade Fusion-io Firmware.

Step 2blank.gif If the above action did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: info
Cause: configuration-error
mibFaultCode: 1494
mibFaultName: fltStorageMezzFlashLifeConfigurationError
moClass: storage:MezzFlashLife
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-

fltStorageMezzFlashLifeDegraded

Fault Code: F1495

Message

Flash Life on server [chassisId]/[slotId] flashStatus: [flashStatus]

Explanation

This fault occurs when the Fusion-io life left is 10 percent or less.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Continue to monitor the the Fusion-io life left and if it reaches 0 percent, the adapter might revert to read-only.

Fault Details

Severity: warning
Cause: equipment-degraded
mibFaultCode: 1495
mibFaultName: fltStorageMezzFlashLifeDegraded
moClass: storage:MezzFlashLife
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/flash-life-
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/flash-life-

fltStorageFlexFlashControllerMismatch

Fault Code: F1496

Message

FlexFlash Controller [id] on server [chassisId]/[slotId] has SD cards with different sizes.FlexFlash Controller [id] on server [id] has SD cards with different sizes.

Explanation

This fault occurs when the flexflash SD Cards dont match in size.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Remove one of the existing cards and replace it with another card that has the same size as the unremoved one.

Fault Details

Severity: major
Cause: equipment-unhealthy
mibFaultCode: 1496
mibFaultName: fltStorageFlexFlashControllerMismatch
moClass: storage:FlexFlashController
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]

fltStorageFlexFlashDriveUnhealthy

Fault Code: F1497

Message

FlexFlash Drive [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [operationState]FlexFlash Drive [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [operationState]

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: equipment-unhealthy
mibFaultCode: 1497
mibFaultName: fltStorageFlexFlashDriveUnhealthy
moClass: storage:FlexFlashDrive
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]/drive-[name]

fltStorageFlexFlashCardUnhealthy

Fault Code: F1498

Message

FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is unhealthy. Reason: [cardHealth]FlexFlash Card [slotNumber] on server [id] is unhealthy. Reason: [cardHealth]

Explanation

This fault occurs when the flexflash card is unhealthy.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif Re-acknowledge the server by setting the flexflash scrub policy to yes. Please note that this action will erase all data in the card(s)

Step 2blank.gif Verify the health of the card. If the above action did not resolve the issue, replace the card

Fault Details

Severity: minor
Cause: equipment-unhealthy
mibFaultCode: 1498
mibFaultName: fltStorageFlexFlashCardUnhealthy
moClass: storage:FlexFlashCard
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/card-[slotNumber]
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/card-[slotNumber]

fltMgmtInterfaceNamedInbandVlanUnresolved

Fault Code: F1506

Message

[configMessage]

Explanation

This fault occurs if there is an issue in Inband interface configuration.

Recommended Action

If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured

Fault Details

Severity: minor
Cause: named-inband-vlan-unresolved
mibFaultCode: 1506
mibFaultName: fltMgmtInterfaceNamedInbandVlanUnresolved
moClass: mgmt:Interface
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]

fltMgmtInterfaceInbandUnsupportedServer

Fault Code: F1507

Message

[configMessage]

Explanation

This fault occurs if there is an issue in Inband interface configuration.

Recommended Action

If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured

Fault Details

Severity: minor
Cause: inband-unsupported-server
mibFaultCode: 1507
mibFaultName: fltMgmtInterfaceInbandUnsupportedServer
moClass: mgmt:Interface
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]

fltMgmtInterfaceInbandUnsupportedFirmware

Fault Code: F1508

Message

[configMessage]

Explanation

This fault occurs if there is an issue in Inband interface configuration.

Recommended Action

If you see this fault check if the VLAN configured on Inband IP is created and the VLAN is present in the Inband Profile or IP address is configured

Fault Details

Severity: minor
Cause: unsupported-cimc-firmware
mibFaultCode: 1508
mibFaultName: fltMgmtInterfaceInbandUnsupportedFirmware
moClass: mgmt:Interface
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/ls-[name]/iface-[mode]
Affected MO: org-[name]/tier-[name]/ls-[name]/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/mgmt/iface-[mode]
Affected MO: sys/fex-[id]/slot-[id]/mgmt/iface-[mode]
Affected MO: sys/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/iface-[mode]
Affected MO: sys/rack-unit-[id]/mgmt/iface-[mode]
Affected MO: sys/switch-[id]/mgmt/iface-[mode]

fltComputePhysicalAdapterMismatch

Fault Code: F1509

Message

Server [id] (service profile: [assignedToDn]) has invalid adapter combinatonServer [chassisId]/[slotId] (service profile: [assignedToDn]) has invalid adapter combination

Explanation

This fault typically occurs because Cisco FPR Manager has detected that the server has an invalid combination of Cisco VICs.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that the valid adapter combinations are installed configuration.

Step 2blank.gif Reacknowledge the server.

Step 3blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: adaptor-mismatch
mibFaultCode: 1509
mibFaultName: fltComputePhysicalAdapterMismatch
moClass: compute:Physical
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]
Affected MO: sys/rack-unit-[id]

fltEquipmentSwitchCardAct2LiteFail

Fault Code: F1510

Message

Failed Identification Test in slot - [id] ([descr]). The module in this slot may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco modules into a Cisco productvis the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program such as SmartNet.

Explanation

This fault occurs when the ACT2 chip fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: act2-fail
mibFaultCode: 1510
mibFaultName: fltEquipmentSwitchCardAct2LiteFail
moClass: equipment:SwitchCard
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/slot-[id]

fltEquipmentTpmSlaveTpm

Fault Code: F1511

Message

Server [chassisId]/[slotId], has a Tpm present on the Slave Board.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: info
Cause: tpm-on-slave-board
mibFaultCode: 1511
mibFaultName: fltEquipmentTpmSlaveTpm
moClass: equipment:Tpm
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/Tpm-[id]
Affected MO: sys/rack-unit-[id]/board/Tpm-[id]

fltPoolElementDuplicatedAssigned

Fault Code: F1512

Message

ID is duplicated assigned for multiple servers(Check FPRC for details)

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: duplicated-assigned
mibFaultCode: 1512
mibFaultName: fltPoolElementDuplicatedAssigned
moClass: pool:Element
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: ip/[id]
Affected MO: iqn/[name]
Affected MO: mac/[id]
Affected MO: uuid/[id]
Affected MO: wwn/[id]

fltSwVlanPortNsResourceStatusWarning

Fault Code: F1519

Message

Total Available Vlan-Port Count on switch [switchId] is below 10%

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: near-max-limit
mibFaultCode: 1519
mibFaultName: fltSwVlanPortNsResourceStatusWarning
moClass: sw:VlanPortNs
Type: management
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/vlan-port-ns

fltNetworkElementMemoryerror

Fault Code: F1520

Message

Fabric Interconnect [id] memory less than expected! Total Memory: [totalMemory] and Expected Memory: [expectedMemory]

Explanation

This fault occurs when the total memory on FI is less than expected.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif You will need to do a manual physical inspection of the DIMMs on the FI. Try removing and reinserting the DIMMs, and verify the Total Memory. If this does not resolve the issue, one of the DIMMs has gone bad and needs to be replaced.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: memory-error
mibFaultCode: 1520
mibFaultName: fltNetworkElementMemoryerror
moClass: network:Element
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]

fltMgmtPmonEntryFPRM process failure

Fault Code: F1541

Message

FPRM process [name] failed on FI [switchId]

Explanation

This fault occurs in an unlikely event of a Cisco FPR Manager process crash. Typically, the failed process restarts and recovers from the problem. Any pending operations are restarted after the process successfully restarts.

Recommended Action

If you see this fault and the process does not restart successfully, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: critical
Cause: fprm-process-failure
mibFaultCode: 1541
mibFaultName: fltMgmtPmonEntryFPRMProcessFailure
moClass: mgmt:PmonEntry
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/mgmt-entity-[id]/[name]

fltSmSlotSmaHeartbeat

Fault Code: F1545

Message

Security module [slotId] - network adapter 1 is not responding

Explanation

This fault occurs when a slot is not operationally up.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reboot the Blade associated with the Slot

Fault Details

Severity: major
Cause: slot-not-responding
mibFaultCode: 1545
mibFaultName: fltSmSlotSmaHeartbeat
moClass: sm:Slot
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]

fltSmSlotBladeNotWorking

Fault Code: F1546

Message

Security Module [slotId] is in failed state. Error: [errorMsg]

Explanation

This fault occurs when a blade discovery is failed or service profile association is failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reboot the blade associated with the slot

Fault Details

Severity: major
Cause: blade-not-working
mibFaultCode: 1546
mibFaultName: fltSmSlotBladeNotWorking
moClass: sm:Slot
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]

fltSmSlotDiskFormatFailed

Fault Code: F1547

Message

Disk format is failed on slot [slotId]

Explanation

This fault occurs when a blade disk formatting is failed.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reformat disk or need disk replacement

Fault Details

Severity: major
Cause: disk-format-failed
mibFaultCode: 1547
mibFaultName: fltSmSlotDiskFormatFailed
moClass: sm:Slot
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]

fltSmSlotBladeSwap

Fault Code: F1548

Message

Blade swap detected on slot [slotId]

Explanation

This fault occurs during the blade swap.

Recommended Action

If you see this fault, take the following action:


Step 1blank.gif 1. Insert the correct blade

Step 2blank.gif 2. Reformat the disk

Fault Details

Severity: critical
Cause: blade-swap
mibFaultCode: 1548
mibFaultName: fltSmSlotBladeSwap
moClass: sm:Slot
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]

fltOsControllerFailedBladeBootup

Fault Code: F1568

Message

Slot [slotId], boot up failed - recovery in progress

Explanation

This fault occurs when blade failed to boot up.

Recommended Action

If you see this fault, do nothing because the blade will try to recover


Step 1blank.gif Reboot the Blade associated with the Slot

Fault Details

Severity: major
Cause: bootup-failure
mibFaultCode: 1568
mibFaultName: fltOsControllerFailedBladeBootup
moClass: os:Controller
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl
Affected MO: sys/os-ctrl
Affected MO: sys/rack-unit-[id]/os-ctrl

fltOsControllerFailedBootupRecovery

Fault Code: F1569

Message

Slot [slotId], boot up failed - exceeded max number of retries

Explanation

This fault occurs when blade failed to boot up.

Recommended Action

If you see this fault, do the following:


Step 1blank.gif Reboot the Blade associated with the Slot

Fault Details

Severity: major
Cause: bootup-failure
mibFaultCode: 1569
mibFaultName: fltOsControllerFailedBootupRecovery
moClass: os:Controller
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl
Affected MO: sys/os-ctrl
Affected MO: sys/rack-unit-[id]/os-ctrl

fltFirmwarePlatformPackBundleVersionMissing

Fault Code: F1595

Message

Platform version is empty in platform firmware package

Explanation

This fault typically occurs when the platform version is not set.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif In the CLI, under scope org/fw-platform-pack, set the platform-bundle-vers to a desired or expected running platform version.

Fault Details

Severity: critical
Cause: default-plaform-version-missing
mibFaultCode: 1595
mibFaultName: fltFirmwarePlatformPackBundleVersionMissing
moClass: firmware:PlatformPack
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: org-[name]/fw-platform-pack-[name]

fltSmSecSvcSwitchConfigFail

Fault Code: F1626

Message

Switch configuration failed for Logical Device. Error: [switchErrorMsg]

Explanation

This fault occurs when switch configuration fails for a LogicalDevice.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: switch-config-failed
mibFaultCode: 1626
mibFaultName: fltSmSecSvcSwitchConfigFail
moClass: sm:SecSvc
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc

fltSmLogicalDeviceIncompleteConfig

Fault Code: F1628

Message

Logical Device [name] is not configured correctly. [errorMsg]

Explanation

This fault occurs when a logical device is not configured correctly.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: logical-device-incomplete-configuration
mibFaultCode: 1628
mibFaultName: fltSmLogicalDeviceIncompleteConfig
moClass: sm:LogicalDevice
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/ld-[name]

fltSmLogicalDeviceLogicalDeviceError

Fault Code: F1629

Message

Error in Logical Device [name]. [errorMsg]

Explanation

This fault occurs when a logical device is in a non-terminal error state.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: logical-device-error
mibFaultCode: 1629
mibFaultName: fltSmLogicalDeviceLogicalDeviceError
moClass: sm:LogicalDevice
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/ld-[name]

fltEtherFtwPortPairBypass

Fault Code: F1638

Message

Port-pair [portName]-[peerPortName] in switch-bypass mode

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: bypass
mibFaultCode: 1638
mibFaultName: fltEtherFtwPortPairBypass
moClass: ether:FtwPortPair
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/fail-to-wire/ftw-port-[slotId]-[aggrPortId]-[portId]-port-[peerSlotId]-[peerAggrPortId]-[peerPortId]

fltCommDateTimeCommNtpConfigurationFailed

Fault Code: F1661

Message

Ntp Configuration failed, please check the error message in Ntp host

Explanation

This fault typically occurs because all Ntp configuration failed adn the system is out of sync.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Verify that whether at least one Ntp configuration succeeded.

Fault Details

Severity: major
Cause: ntp-config-failed
mibFaultCode: 1661
mibFaultName: fltCommDateTimeCommNtpConfigurationFailed
moClass: comm:DateTime
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/datetime-svc

fltSmConfigIssueLogicalDeviceConfigError

Fault Code: F1671

Message

[errorMsg]

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: logical-device-config-error
mibFaultCode: 1671
mibFaultName: fltSmConfigIssueLogicalDeviceConfigError
moClass: sm:ConfigIssue
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/ld-[name]/config-issue-[moKey]

fltSmAppAppImageCorrupted

Fault Code: F1673

Message

The application image [appId] is corrupted

Explanation

This fault occurs when an application meta data cannot be reloaded.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Re-download the application from a trusted source

Fault Details

Severity: major
Cause: app-img-corrupted
mibFaultCode: 1673
mibFaultName: fltSmAppAppImageCorrupted
moClass: sm:App
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/app-[name]-[version]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/app-[name]-[version]

fltEquipmentXcvrNonSupportedXcvr

Fault Code: F1677

Message

The transceiver inserted in port Ethernet [slotId]/[aggrPortId]/[portId] is not a Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco modules into a Cisco product is the cause of a support issue, Cisco TAC reserves the right to deny support

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: fru-problem
mibFaultCode: 1677
mibFaultName: fltEquipmentXcvrNonSupportedXcvr
moClass: equipment:Xcvr
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/diag/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/slot-[id]/[type]/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/chassis-[id]/sw-slot-[id]/[type]/port-[portId]/transceiver
Affected MO: sys/fex-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/fex-[id]/slot-[id]/[type]/port-[portId]/transceiver
Affected MO: sys/rack-unit-[id]/diag/port-[portId]/transceiver
Affected MO: sys/switch-[id]/slot-[id]/[type]/aggr-port-[aggrPortId]/port-[portId]/transceiver
Affected MO: sys/switch-[id]/slot-[id]/[type]/port-[portId]/transceiver

fltFabricSspEthMonDelAllSessEnabled

Fault Code: F1679

Message

Packet Capture Session [name] was still enabled when delete-all-sessions was issued

Explanation

This fault occurs when user issues the delete-all-sessions command when one of the packet capture sessions is still enabled

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Disable the enabled session

Step 2blank.gif Retry the delete-all-sessions command

Fault Details

Severity: warning
Cause: config-error
mibFaultCode: 1679
mibFaultName: fltFabricSspEthMonDelAllSessEnabled
moClass: fabric:SspEthMon
Type: network
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/ssppktcapmon/ssp-mon-[name]

fltIpsecConnectionIpsecConnInvalidKey

Fault Code: F1681

Message

Invalid keyring [keyring] for IPSec connection [name]

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: ipsec-config-error
mibFaultCode: 1681
mibFaultName: fltIpsecConnectionIpsecConnInvalidKey
moClass: ipsec:Connection
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/ipsec-ext/conn-[name]

fltIpsecConnectionIpsecConnInvalidCert

Fault Code: F1682

Message

Invalid Cert of keyring [keyring] for IPSec connection [name]

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: ipsec-config-error
mibFaultCode: 1682
mibFaultName: fltIpsecConnectionIpsecConnInvalidCert
moClass: ipsec:Connection
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/ipsec-ext/conn-[name]

fltIpsecAuthorityIpsecAuthorInvalidTp

Fault Code: F1683

Message

Invalid trustpoint [tpName] for IPSec

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: ipsec-config-error
mibFaultCode: 1683
mibFaultName: fltIpsecAuthorityIpsecAuthorInvalidTp
moClass: ipsec:Authority
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/ipsec-ext/author-[tpName]

fltSmHotfixHotfixInstallFailed

Fault Code: F1691

Message

Failed to install Hotfix [version] on [appName]-[identifier] in slot [slotId]. Error: [errorMsg]

Explanation

This fault occurs when hotfix installation fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: hotfix-install-failed
mibFaultCode: 1691
mibFaultName: fltSmHotfixHotfixInstallFailed
moClass: sm:Hotfix
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/hotfix-[version]
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]/hotfix-[version]

fltSmHotfixHotfixError

Fault Code: F1692

Message

Error in Hotfix [version] on appInstance [appName]-[identifier] in slot [slotId]. Error: [errorMsg]

Explanation

This fault occurs when hotfix is in a non-terminal error state.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: hotfix-error
mibFaultCode: 1692
mibFaultName: fltSmHotfixHotfixError
moClass: sm:Hotfix
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/hotfix-[version]
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]/hotfix-[version]

fltSmCloudConnectorCloudRegistrationFailed

Fault Code: F1694

Message

Failed to register the device with the cloud. Error: [errorMessage]

Explanation

This fault occurs when registration of device with cloud fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: cloud-registration-failed
mibFaultCode: 1694
mibFaultName: fltSmCloudConnectorCloudRegistrationFailed
moClass: sm:CloudConnector
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/cloud-connector

fltSmCloudConnectorCloudUnregistrationFailed

Fault Code: F1695

Message

Failed to unregister the device with the cloud. Error: [errorMessage]

Explanation

This fault occurs when unregistration of device with cloud fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: cloud-unregistration-failed
mibFaultCode: 1695
mibFaultName: fltSmCloudConnectorCloudUnregistrationFailed
moClass: sm:CloudConnector
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/cloud-connector

fltSmUnsignedCspLicenseUnsignedCSPLicenseInstalled

Fault Code: F1716

Message

Unsigned CSP License Installed [licenseFileName]

Explanation

This fault occurs when Unsigned CSP License is installed on the system.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: license-installed
mibFaultCode: 1716
mibFaultName: fltSmUnsignedCspLicenseUnsignedCSPLicenseInstalled
moClass: sm:UnsignedCspLicense
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/unsigned-csp-license

fltSdLinkVnicConfigFail

Fault Code: F1717

Message

Failed to set the oper state for vnic(s) [failedCfgVnics].

Explanation

This fault occurs when the vnic for this link failed to be configured.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Failed to set the oper state for vnic(s)

Fault Details

Severity: major
Cause: vnic-config-failed
mibFaultCode: 1717
mibFaultName: fltSdLinkVnicConfigFail
moClass: sd:Link
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]/sub-ldulink-[subId]
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/sub-ldulink-[subId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]/sub-ldulink-[subId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/sub-ldulink-[subId]

fltNwctrlCardConfigOffline

Fault Code: F1718

Message

Network Module [slotId] taken offline by user. Please check audit-logs for user activity.

Explanation

This fault occurs when the switch card is powered down.

Recommended Action

If you see this fault, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: module-offline
mibFaultCode: 1718
mibFaultName: fltNwctrlCardConfigOffline
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltNwctrlCardConfigFailed

Fault Code: F1719

Message

Network Module [slotId] is in failed state. If new hardware is inserted, please ensure proper firmware is installed. Otherwise, please collect the detailed FPRM techsupport from the local-mgmt shell and contact Cisco.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: module-failed
mibFaultCode: 1719
mibFaultName: fltNwctrlCardConfigFailed
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltNwctrlCardConfigError

Fault Code: F1720

Message

Network Module [slotId] is in error state. If new hardware is inserted, please ensure proper firmware is installed. Otherwise, please collect the detailed FPRM techsupport from the local-mgmt shell and contact Cisco.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: module-error
mibFaultCode: 1720
mibFaultName: fltNwctrlCardConfigError
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltNwctrlCardConfigOirFailed

Fault Code: F1721

Message

Network Module [slotId] is in failed state. Hot swap with a different type of module is not supported. Please reboot system.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: module-oir-failed
mibFaultCode: 1721
mibFaultName: fltNwctrlCardConfigOirFailed
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltNwctrlCardConfigOirInvalid

Fault Code: F1722

Message

Network Module [slotId] is in failed state. Hot swap of this type of module is not supported. Please reboot system.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: module-oir-invalid
mibFaultCode: 1722
mibFaultName: fltNwctrlCardConfigOirInvalid
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltNwctrlCardConfigRemoval

Fault Code: F1723

Message

Network Module [slotId] removed. Please re-insert module or use acknowledge command to confirm module removal.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: module-removal
mibFaultCode: 1723
mibFaultName: fltNwctrlCardConfigRemoval
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltNwctrlCardConfigMismatch

Fault Code: F1724

Message

Network Module [slotId] is of different type than previously inserted module in this slot. Please use acknowledge command to confirm module replacement.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: module-mismatch
mibFaultCode: 1724
mibFaultName: fltNwctrlCardConfigMismatch
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltNwctrlCardConfigSupriseRemoval

Fault Code: F1725

Message

Network Module [slotId] removed when in online state. It is recommended to set module offline before removal. Please re-insert module or use acknowledge command to confirm module removal.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: module-suprise-removal
mibFaultCode: 1725
mibFaultName: fltNwctrlCardConfigSupriseRemoval
moClass: nwctrl:CardConfig
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/card-[slotId]

fltFirmwareRunnableAdapterUpgradeRequired

Fault Code: F1729

Message

Adapter [id] on Security Module [slotId] requires a critical firmware upgrade. Please see Adapter Bootloader Upgrade instructions in the FXOS Release Notes posted with this release.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: adapter-boot-upgrade-required
mibFaultCode: 1729
mibFaultName: fltFirmwareRunnableAdapterUpgradeRequired
moClass: firmware:Runnable
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-runnable
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-runnable
Affected MO: sys/fex-[id]/mgmt/fw-runnable
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-runnable
Affected MO: sys/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-runnable
Affected MO: sys/rack-unit-[id]/mgmt/fw-runnable
Affected MO: sys/switch-[id]/mgmt/fw-runnable

fltSmClusterBootstrapCclSubnetNotSupported

Fault Code: F1732

Message

Customization Cluster Control Link Subnet is not supported by the application

Explanation

This fault occurs when Ccl Subnet is not in default value when customization not supported by application.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Upgrade application or set ccl Network to 0.0.0.0

Fault Details

Severity: major
Cause: ccl-subnet-not-supported
mibFaultCode: 1732
mibFaultName: fltSmClusterBootstrapCclSubnetNotSupported
moClass: sm:ClusterBootstrap
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/ld-[name]/cluster-bootstrap

fltSmAppInstanceFailedConversion

Fault Code: F1735

Message

Unrecoverable error during conversion of App Instance [appName]-[startupVersion] on slot [slotId] during FXOS upgrade

Explanation

This fault occurs if we could not automatically convert smAppInstance to smAppInstance2 during upgrade to Fairlop

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: conversion-failed
mibFaultCode: 1735
mibFaultName: fltSmAppInstanceFailedConversion
moClass: sm:AppInstance
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]

fltSmAppInstance2AppNotResponding

Fault Code: F1736

Message

App Instance [appName]-[identifier] with version [runningVersion] on slot [slotId] is not responding

Explanation

This fault occurs when an app instance is not responding.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-not-responding
mibFaultCode: 1736
mibFaultName: fltSmAppInstance2AppNotResponding
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2AppInstallFailed

Fault Code: F1737

Message

Failed to install App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId]. Error: [errorMsg]

Explanation

This fault occurs when an app instance installation fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-install-failed
mibFaultCode: 1737
mibFaultName: fltSmAppInstance2AppInstallFailed
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2AppStartFailed

Fault Code: F1738

Message

Failed to start App Instance [appName]-[identifier] with version [runningVersion] on slot [slotId]. Error: [errorMsg]

Explanation

This fault occurs when an app instance start fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-start-failed
mibFaultCode: 1738
mibFaultName: fltSmAppInstance2AppStartFailed
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2AppUpdateFailed

Fault Code: F1739

Message

Failed to update App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId]. Error: [errorMsg]

Explanation

This fault occurs when an app instance updation fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-update-failed
mibFaultCode: 1739
mibFaultName: fltSmAppInstance2AppUpdateFailed
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2AppStopFailed

Fault Code: F1740

Message

Failed to stop App Instance [appName]-[identifier] with version [runningVersion] on slot [slotId]. Error: [errorMsg]

Explanation

This fault occurs when an app instance stop fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-stop-failed
mibFaultCode: 1740
mibFaultName: fltSmAppInstance2AppStopFailed
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2AppNotInstalled

Fault Code: F1741

Message

App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId] is not installed. Error: [errorMsg]

Explanation

This fault occurs when an app instance is not installed.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-not-installed
mibFaultCode: 1741
mibFaultName: fltSmAppInstance2AppNotInstalled
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2AppInstanceError

Fault Code: F1742

Message

Error in App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId]. [errorMsg]

Explanation

This fault occurs when an app instance is in a non-terminal error state.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: minor
Cause: appinstance-error
mibFaultCode: 1742
mibFaultName: fltSmAppInstance2AppInstanceError
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2AppInstanceUnsupported

Fault Code: F1743

Message

App Instance [appName]-[identifier] with version [startupVersion] on slot [slotId] is not supported in the current bundle. Error: [errorMsg]

Explanation

This fault occurs when an app instance is not supported in the current platform bundle

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-unsupported
mibFaultCode: 1743
mibFaultName: fltSmAppInstance2AppInstanceUnsupported
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmAppInstance2SoftwareIncompatible

Fault Code: F1744

Message

[versionIncompatibleErrorMgr]

Explanation

This fault occurs when this main app version is not compatible with decorator version or this decorator version is not compatible with main app version.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Remove data port decorator from logical device

Fault Details

Severity: major
Cause: software-version-incompatible
mibFaultCode: 1744
mibFaultName: fltSmAppInstance2SoftwareIncompatible
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltNetworkElementSamconfig

Fault Code: F1750

Message

The Supervisor’s sam.config file stored in the /opt partition is not accessible

Explanation

This fault occurs when the Supervisor is not able to access the persistent store of the sam.config file. Attempts at modifying the admin password, Supervisor OOB IPv4/6 addresses, DNS server, and strong password enforcement may fail.

Recommended Action

If you see this fault in a non-Cleared state, take the following actions:


Step 1blank.gif Create a show tech-support fprm detail file and copy it to a remote loaction.

Step 2blank.gif Backup the existing configuration using the export-config feature and copy it to a remote location.

Step 3blank.gif Contact Cisco TAC.

Fault Details

Severity: critical
Cause: file-missing
mibFaultCode: 1750
mibFaultName: fltNetworkElementSamconfig
moClass: network:Element
Type: configuration
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]

fltSmAppInstance2AppFaultState

Fault Code: F1757

Message

AppInstance [appName]-[identifier] with version [runningVersion] on slot [slotId] is in failed state. Error: [errorMsg]

Explanation

This fault occurs when AppInstance is in "fault" state.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: appinstance-fault-state
mibFaultCode: 1757
mibFaultName: fltSmAppInstance2AppFaultState
moClass: sm:AppInstance2
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]

fltSmExternalPortLinkConflictConfig

Fault Code: F1758

Message

The external-port-link [name] conflict with the application. [errorDescription]. To correct it, synchronize and remove the conflict sub-interface, save and deploy from Firepower Management Center. Remove and recreate external-port-link [name] from MIO, then, synchronize it again from Firepower Management Center.

Explanation

This fault occurs when an external-port-link has conflict with the application.

Recommended Action

If you see this fault, take the either of following two actions:


Step 1blank.gif Delete the conflict external-port-link from MIO, and use another sub-interface to create a new external-port-llink

Step 2blank.gif Sync in Firepower Management Center to get the new sub-interface


Step 1blank.gif Delete the conflict sub-interface from Firepower Management Center

Step 2blank.gif Save and deploy the changes from Firepower Management Center

Step 3blank.gif Delete the conflict external-port-link and recreate it again from MIO

Step 4blank.gif Sync again in Firepower Management Center to get the new sub-interface

Fault Details

Severity: major
Cause: external-port-link-conflict-configuration
mibFaultCode: 1758
mibFaultName: fltSmExternalPortLinkConflictConfig
moClass: sm:ExternalPortLink
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/ld-[name]/ext-portlink-[name]

fltSmSlotAdapter2NotResponding

Fault Code: F1760

Message

[errorMsg]

Explanation

This fault occurs if adapter 2 is not responding to heartbeats.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Reboot the security module associated with the slot

Fault Details

Severity: major
Cause: adapter-2-not-responding
mibFaultCode: 1760
mibFaultName: fltSmSlotAdapter2NotResponding
moClass: sm:Slot
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]

fltSmHwCryptoHwCryptoNotOperable

Fault Code: F1761

Message

Hardware crypto is enabled but not operable on [appName]-[identifier]. Reason: HwCryptoVersion is ’[hwCryptoVersion]’.

Explanation

This fault occurs when admin state of hardware crypto is set to enabled but the instance does not support it, or there is a failure when retrieving the hardware crypto version.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Set admin state of hardware crypto to ’disabled’ to free the hardware crypto resource on the application instance

Fault Details

Severity: major
Cause: hardware-crypto-version-unsupported-or-failure
mibFaultCode: 1761
mibFaultName: fltSmHwCryptoHwCryptoNotOperable
moClass: sm:HwCrypto
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/hwCrypto
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/hwCrypto

fltSmErrorError0

Fault Code: F1762

Message

[operStr] failed on slot [slotId]:[errorMsg]

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: generic-error
mibFaultCode: 1762
mibFaultName: fltSmErrorError0
moClass: sm:Error
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/error-[moKey]
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]/error-[moKey]

fltSmErrorError1

Fault Code: F1763

Message

Sync Data External Port Link is enabled on [identifier] with error: [errorMsg] on slot [slotId]. Please ’set link-state-sync disabled’ on the Logical Device.

Explanation

This fault occurs when Sync Data External Port Link is enabled with error.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Set Sync Data External Port Link to ’disabled’, or upgrade the FTD to a supported version if it is an unsupported one.

Fault Details

Severity: major
Cause: generic-error
mibFaultCode: 1763
mibFaultName: fltSmErrorError1
moClass: sm:Error
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]-[identifier]/error-[moKey]
Affected MO: sec-svc/slot-[slotId]/app-inst-[appName]/error-[moKey]

fltPkiTpAutoImportTp-auto-import-failure

Fault Code: F1764

Message

TrustPoints Auto Import Failure.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: invalid-tp-auto-import
mibFaultCode: 1764
mibFaultName: fltPkiTpAutoImportTpAutoImportFailure
moClass: pki:TpAutoImport
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/pki-ext/tpAutoImport-

fltPkiTpAutoImportTp-auto-import-attempt

Fault Code: F1765

Message

Last TrustPoints Auto Import Attempt.

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: info
Cause: tp-auto-import
mibFaultCode: 1765
mibFaultName: fltPkiTpAutoImportTpAutoImportAttempt
moClass: pki:TpAutoImport
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/pki-ext/tpAutoImport-

fltPkiKeyRingEc

Fault Code: F1766

Message

[name] Keyring’s ECDSA elliptic-curve is invalid.

Explanation

This fault occurs when ECDSA keyring is created without elliptic-curve set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: invalid-keyring-ec
mibFaultCode: 1766
mibFaultName: fltPkiKeyRingEc
moClass: pki:KeyRing
Type: security
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/pki-ext/keyring-[name]

fltCommTelemetryTelemetryRegistrationFailed

Fault Code: F1767

Message

Auto registration of device for telemetry failed. Error: [errorMessage]

Explanation

This fault occurs when registration of device with cloud fails for telemetry.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: telemetry-registration-failed
mibFaultCode: 1767
mibFaultName: fltCommTelemetryTelemetryRegistrationFailed
moClass: comm:Telemetry
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/telemetry

fltCommTelemetryTelemetryUnregistrationFailed

Fault Code: F1768

Message

Failed to unregister the device with the cloud. Error: [errorMessage]

Explanation

This fault occurs when unregistration of device with cloud fails.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: telemetry-unregistration-failed
mibFaultCode: 1768
mibFaultName: fltCommTelemetryTelemetryUnregistrationFailed
moClass: comm:Telemetry
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/telemetry

fltCommTelemetryTelemetryGetDataFailed

Fault Code: F1769

Message

Failed to get telemetry data from application. Error: [errorMessage]

Explanation

This fault occurs when there is a failure to get telemetry data from the application.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: telemetry-get-data-failed
mibFaultCode: 1769
mibFaultName: fltCommTelemetryTelemetryGetDataFailed
moClass: comm:Telemetry
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/telemetry

fltCommTelemetryTelemetrySendDataFailed

Fault Code: F1770

Message

Failed to send telemetry data. Error: [errorMessage]

Explanation

This fault occurs when there is a failure to send telemetry data.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: telemetry-send-data-failed
mibFaultCode: 1770
mibFaultName: fltCommTelemetryTelemetrySendDataFailed
moClass: comm:Telemetry
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/telemetry

fltAaaUserEpPasswordEncryptionKeyNotSet

Fault Code: F1771

Message

The password encryption key has not been set.

Explanation

This fault typically occurs because a password encryption key is not set on the system. The password encryption key is used for protecting credentials when a user exports the system’s configurations

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif Scope to security, and run the command "set password-encryption-key".

Fault Details

Severity: warning
Cause: password-encryption-key-not-set
mibFaultCode: 1771
mibFaultName: fltAaaUserEpPasswordEncryptionKeyNotSet
moClass: aaa:UserEp
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/user-ext

fltCommSshSSh3desUsageNotRecommended

Fault Code: F1772

Message

Ssh-server is configured with 3des as encrypt alogrithm. 3des is deprecated and the usage is disallowed after 2023.

Explanation

This fault occurs when ssh server is configured with 3des encryption algorithm.

Recommended Action

Reconfigure ssh server without 3des as an encryption algorithm.

Fault Details

Severity: warning
Cause: ssh-3des-usage-not-recommended
mibFaultCode: 1772
mibFaultName: fltCommSshSSh3desUsageNotRecommended
moClass: comm:Ssh
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/ssh-svc

fltCommSshcSshc3desUsageNotRecommended

Fault Code: F1773

Message

Ssh-client is configured with 3des as encrypt alogrithm. 3des is deprecated and the usage is disallowed after 2023.

Explanation

This fault occurs when ssh client is configured with 3des encryption algorithm.

Recommended Action

Reconfigure ssh client without 3des as an encryption algorithm.

Fault Details

Severity: warning
Cause: sshc-3des-usage-not-recommended
mibFaultCode: 1773
mibFaultName: fltCommSshcSshc3desUsageNotRecommended
moClass: comm:Sshc
Type: configuration
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/svc-ext/sshc-svc

fltSdInternalMgmtBootstrapInternalMgmtVnicConfigFail

Fault Code: F1778

Message

Failed to allocate internal mgmt vnic for application instance [appName]-[identifier] on slot [slotId]

Explanation

This fault occurs when vnic for internal mgmt bootstrap (in decorator case) was not allocated.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: internal-mgmt-vnic-config-fail
mibFaultCode: 1778
mibFaultName: fltSdInternalMgmtBootstrapInternalMgmtVnicConfigFail
moClass: sd:InternalMgmtBootstrap
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/internal-mgmt-bootstrap

fltSdExternalLduLinkExternalLduLinkVnicConfigFail

Fault Code: F1779

Message

Failed to allocate vnic for ExternalLduLink [name] in LogicalDevice [ldName](type:[type]) for [appName] on slot [slotId]

Explanation

This fault occurs when vnic for ExternalLduLink was not allocated.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: external-ldu-link-vnic-config-fail
mibFaultCode: 1779
mibFaultName: fltSdExternalLduLinkExternalLduLinkVnicConfigFail
moClass: sd:ExternalLduLink
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/ext-ldulink-[slotId]-[aggrPortId]-[portId]-[appName]

fltSdAppLduLinkAppLduLinkEndpoint1VnicConfigFail

Fault Code: F1780

Message

Failed to allocate vnic for AppLduLink [name] in LogicalDevice [ldName](type:[type]) for [appName] on slot [slotId]

Explanation

This fault occurs when vnics for EndPoint1(decorator) in AppLduLink are not allocated.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: app-ldu-link-endpoint1-vnic-config-fail
mibFaultCode: 1780
mibFaultName: fltSdAppLduLinkAppLduLinkEndpoint1VnicConfigFail
moClass: sd:AppLduLink
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]

fltSdAppLduLinkAppLduLinkEndpoint2VnicConfigFail

Fault Code: F1781

Message

Failed to allocate vnic for AppLduLink [name] in LogicalDevice [ldName](type:[type]) for main app on slot [slotId]

Explanation

This fault occurs when vnics for EndPoint2(main app) in AppLduLink are not allocated.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: app-ldu-link-endpoint2-vnic-config-fail
mibFaultCode: 1781
mibFaultName: fltSdAppLduLinkAppLduLinkEndpoint2VnicConfigFail
moClass: sd:AppLduLink
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys-secsvc/ld-[name]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/ldu-[slotId]/app-ldulink-[name]-[endpoint1AppInstId]-[endpoint2AppInstId]

fltSdPreAllocatedVnicVnicPreAllocationFail

Fault Code: F1782

Message

Failed to pre-allocate vnic for application instance [appName]-[identifier] on slot [slotId] (type:[portType])

Explanation

This fault occurs when vnics are not pre-allocated for native/container FTD instances.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: vnic-pre-allocation-fail
mibFaultCode: 1782
mibFaultName: fltSdPreAllocatedVnicVnicPreAllocationFail
moClass: sd:PreAllocatedVnic
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys-secsvc/slot-[slotId]/app-inst-[appInstId]/pre-allocated-vnic-[portType]-[mgmtSubType]

fltSdLogicalDeviceDifferentResourcesInProfile

Fault Code: F1783

Message

[resourceFaultMsg]

Explanation

This fault occurs when app instances of logical device have different resources in resource profile.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: warning
Cause: different-resources-in-profile
mibFaultCode: 1783
mibFaultName: fltSdLogicalDeviceDifferentResourcesInProfile
moClass: sd:LogicalDevice
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys-secsvc/ld-[name]

fltMemoryArrayServer-bad-memorry

Fault Code: F1784

Message

Physical memory size [currCapacity] on server [chassisId]/[slotId] is smaller than expected.Physical memory size [currCapacity] on server [id] is smaller than expected.

Explanation

This fault typically occurs because Cisco FPR Manager has detected unsupported DIMM in the server. For example, the model, vendor, or revision is not recognized.

Recommended Action

If you see this fault, take the following actions:


Step 1blank.gif If necessary, inspect or replace the physical memory DIMM in the blade.

Step 2blank.gif If the above actions did not resolve the issue, create a show tech-support file and contact Cisco TAC.

Fault Details

Severity: major
Cause: bad-memory-detect
mibFaultCode: 1784
mibFaultName: fltMemoryArrayServerBadMemorry
moClass: memory:Array
Type: equipment
Callhome: diagnostic
Auto Cleared: true
Is Implemented: true
Affected MO: sys/chassis-[id]/blade-[slotId]/board/memarray-[id]
Affected MO: sys/rack-unit-[id]/board/memarray-[id]

fltFirmwareVersionIssueImageVersionMismatch

Fault Code: F1785

Message

Mismatched [mismatchType] image version [version] detected. Expected version [installedImageVersion] from FXOS [installedPackageVersion].

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: image-version-mismatch
mibFaultCode: 1785
mibFaultName: fltFirmwareVersionIssueImageVersionMismatch
moClass: firmware:VersionIssue
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: capabilities/ep/mgmt-ext/fw-[deployment]/version-issue
Affected MO: capabilities/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-eth-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/host-fc-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/adaptor-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/bios/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/graphics-card-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/disk-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-[type]-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/board/storage-flexflash-[id]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/bios/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/ext-board-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/blade-[slotId]/os-ctrl/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/epmfpga-[slot]/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/fpga/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/rommon/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/slot-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/chassis-[id]/sw-slot-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/fex-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/fex-[id]/slot-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/mgmt/fw-[deployment]/version-issue
Affected MO: sys/os-ctrl/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-eth-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/adaptor-[id]/host-fc-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/adaptor-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/bios/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/graphics-card-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/disk-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/storage-[type]-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/board/storage-flexflash-[id]/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/ext-board-[id]/bios/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/ext-board-[id]/boardController/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/ext-board-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/mgmt/fw-[deployment]/version-issue
Affected MO: sys/rack-unit-[id]/os-ctrl/fw-[deployment]/version-issue
Affected MO: sys/switch-[id]/mgmt/fw-[deployment]/version-issue

fltFabricComputeSlotEpBladeDecommissionFail

Fault Code: F1786

Message

Service Module [slotId] - Decommission failed, reason: [failReason]

Explanation

This fault occurs when Cisco FPR Manager failed to decommission the blade.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: critical
Cause: decommission-fail
mibFaultCode: 1786
mibFaultName: fltFabricComputeSlotEpBladeDecommissionFail
moClass: fabric:ComputeSlotEp
Type: equipment
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: fabric/server/chassis-[chassisId]/slot-[slotId]

fltEtherFtwPortPairPhyBypass

Fault Code: F1787

Message

Port-pair [portName]-[peerPortName] in phy-bypass mode due to watchdog timeout

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: bypass
mibFaultCode: 1787
mibFaultName: fltEtherFtwPortPairPhyBypass
moClass: ether:FtwPortPair
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/fail-to-wire/ftw-port-[slotId]-[aggrPortId]-[portId]-port-[peerSlotId]-[peerAggrPortId]-[peerPortId]

fltEtherFtwPortPairPhyBypassErr

Fault Code: F1788

Message

Port-pair [portName]-[peerPortName] in phy-bypass mode due to switch config error

Explanation

None set.

Recommended Action

Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. If you cannot resolve the issue, create a show tech-support file and contact Cisco Technical Support.

Fault Details

Severity: major
Cause: bypass
mibFaultCode: 1788
mibFaultName: fltEtherFtwPortPairPhyBypassErr
moClass: ether:FtwPortPair
Type: server
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/switch-[id]/fail-to-wire/ftw-port-[slotId]-[aggrPortId]-[portId]-port-[peerSlotId]-[peerAggrPortId]-[peerPortId]

fltMgmtImporterConfiguration import failed

Fault Code: F1789

Message

Importing configuration failed: [errMsg]

Explanation

This fault occurs if error happens when importing a configuration file

Recommended Action

If you see this fault, please take actions based on the error description.

Fault Details

Severity: major
Cause: config-import-failed
mibFaultCode: 1789
mibFaultName: fltMgmtImporterConfigurationImportFailed
moClass: mgmt:Importer
Type: management
Callhome: none
Auto Cleared: true
Is Implemented: true
Affected MO: sys/import-config-[hostname]
 
The following are MIB faults of Firepower 9300 and 4100 devices:

cfprFaultInst satellite-connection-absent

Message

No link between IOM port $chassisId$/$slotId$/$portId$ and fabric interconnect $switchId$:$peerSlotId$/$peerPortId$

Fault Details

Severity: major
Cause: satellite-connection-absent
Type: connectivity
 

cfprFaultInst satellite-wiring-problem

Message

Invalid connection between IOM port $chassisId$/$slotId$/$portId$ and fabric interconnect $switchId$:$peerSlotId$/$peerPortId$

Fault Details

Severity: info
Cause: satellite-mis-connected
Type: connectivity

cfprFaultInst satellite-wiring-numbers-unexpected

Message

Chassis discovery policy conflict: Link IOM $chassisId$/$slotId$/$portId$ to fabric interconnect $switchId$:$peerSlotId$/$peerPortId$ not configured

Fault Details

Severity: info
Cause: unexpected-number-of-links
Type: connectivity

cfprFaultInst powerSupplyProblem

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ power: $power$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ power: $power$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ power: $power$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ power: $power$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst offline

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ power: $power$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ power: $power$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ power: $power$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ power: $power$

Fault Details

Severity: warning
Cause: equipment-offline
Type: environmental

cfprFaultInst powerSupplyShutdown

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ shutdown reason:$powerStateQualifier$

Fault Details

Severity: major
Cause: equipment-offline
Type: environmental

cfprFaultInst identity-unestablishable

Message

Chassis $id$ has an invalid FRU

Fault Details

Severity: major
Cause: identity-unestablishable
Type: equipment

cfprFaultInst identity-unestablishable

Message

Fex $id$ has an invalid FRU

Fault Details

Severity: major
Cause: identity-unestablishable
Type: equipment

cfprFaultInst fex-unsupported

Message

Fex $id$ with model $model$ is unsupported

Fault Details

Severity: major
Cause: fex-unsupported
Type: equipment

cfprFaultInst degraded

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst degraded

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fan $id$ in fex $[ancestor:equipment:Fex:id]$ operability: $operability$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

Chassis $id$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst seeprom-inoperable

Message

Device $id$ SEEPROM operability: $seepromOperState$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment
 

cfprFaultInst inoperable

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst inoperable

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fan $id$ in fex $[ancestor:equipment:Fex:id]$ operability: $operability$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst inoperable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ operability: $operability$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst removed

Message

$side$ IOM $chassisId$/$id$ ($switchId$) is removed

Fault Details

Severity: critical
Cause: equipment-removed
Type: equipment

cfprFaultInst inaccessible

Message

$side$ IOM $chassisId$/$id$ ($switchId$) is inaccessible

Fault Details

Severity: critical
Cause: equipment-inaccessible
Type: equipment

cfprFaultInst post-failure

Message

$side$ IOM $chassisId$/$id$ ($switchId$) POST failure

Fault Details

Severity: major
Cause: equipment-problem
Type: equipment

cfprFaultInst post-failure

Message

fex $id$ POST failure

Fault Details

Severity: major
Cause: equipment-problem
Type: equipment

cfprFaultInst missing

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ presence: $presence$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ presence: $presence$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ presence: $presence$

Fault Details

Severity: warning
Cause: equipment-missing
Type: equipment

cfprFaultInst missing

Message

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ presence: $presence$

Fan $id$ in fex $[ancestor:equipment:Fex:id]$ presence: $presence$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ presence: $presence$

Fault Details

Severity: warning
Cause: equipment-missing
Type: equipment

cfprFaultInst thermalProblem

Message

$side$ IOM $chassisId$/$id$ ($switchId$) operState: $operState$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

$side$ IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

$side$ IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

$side$ IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst voltageThresholdNonCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ voltage: $voltage$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ voltage: $voltage$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ voltage: $voltage$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ voltage: $voltage$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ voltage: $voltage$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ voltage: $voltage$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdNonRecoverable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ voltage: $voltage$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ voltage: $voltage$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ voltage: $voltage$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: critical
Cause: voltage-problem
Type: environmental

cfprFaultInst perfThresholdNonCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ output power: $perf$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ output power: $perf$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ output power: $perf$

Fault Details

Severity: minor
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ output power: $perf$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ output power: $perf$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ output power: $perf$

Fault Details

Severity: major
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdNonRecoverable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ output power: $perf$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ output power: $perf$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ output power: $perf$

Fault Details

Severity: critical
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdNonCritical

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: info
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdCritical

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: info
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdNonRecoverable

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: info
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdLowerNonRecoverable

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: critical
Cause: performance-problem
Type: equipment

cfprFaultInst firmwareUpgrade

Message

Chassis controller in IOM $chassisId$/$id$ ($switchId$) firmware upgrade problem: $upgradeStatus$

Fault Details

Severity: major
Cause: firmware-upgrade-problem
Type: equipment

cfprFaultInst unsupportedConnectivity

Message

Current connectivity for chassis $id$ does not match discovery policy: $configState$

Fault Details

Severity: major
Cause: unsupported-connectivity-configuration
Type: connectivity

cfprFaultInst unacknowledged

Message

Chassis $id$ connectivity configuration: $configState$

Fault Details

Severity: warning
Cause: equipment-unacknowledged
Type: connectivity

cfprFaultInst unsupportedConnectivity

Message

IOM $chassisId$/$id$ ($switchId$) current connectivity does not match discovery policy or connectivity is unsupported: $configState$

Fault Details

Severity: major
Cause: unsupported-connectivity-configuration
Type: connectivity

cfprFaultInst autoUpgradingFirmware

Message

IOM $chassisId$/$id$ ($switchId$) is auto upgrading firmware

Fault Details

Severity: major
Cause: auto-firmware-upgrade
Type: connectivity

cfprFaultInst unacknowledged

Message

IOM $chassisId$/$id$ ($switchId$) connectivity configuration: $configState$

Fault Details

Severity: warning
Cause: equipment-unacknowledged
Type: connectivity

cfprFaultInst peerDisconnected

Message

IOM $chassisId$/$id$ ($switchId$) peer connectivity: $peerCommStatus$

Fault Details

Severity: warning
Cause: equipment-disconnected
Type: connectivity

cfprFaultInst identity

Message

Chassis $id$ has a mismatch between FRU identity reported by Fabric/IOM vs. FRU identity reported by CMC

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst invalid-fru

Message

Chassis $id$ has a empty value for FRU identity reported by CMC.

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst powerProblem

Message

Power state on chassis $id$ is $power$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Thermal condition on chassis $id$. $thermalStateQualifier$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Thermal condition on chassis $id$. $thermalStateQualifier$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst identity

Message

$side$ IOM $chassisId$/$id$ ($switchId$) has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst identity

Message

Fex $id$ has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst identity

Message

Fan Module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ has a malformed FRU

Fan Module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ has a malformed FRU

Fan Module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst identity

Message

Power supply $id$ on chassis $[ancestor:equipment:Chassis:id]$ has a malformed FRU

Power supply $id$ on server $[ancestor:compute:RackUnit:id]$ has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst PowerThreshold

Message

Power supply $id$ on chassis $[ancestor:equipment:Chassis:id]$ has exceeded its power threshold

Power supply $id$ on server $[ancestor:compute:RackUnit:id]$ has exceeded its power threshold

Fault Details

Severity: critical
Cause: power-problem
Type: equipment

cfprFaultInst InputError

Message

Power supply $id$ on chassis $[ancestor:equipment:Chassis:id]$ has disconnected cable or bad input voltage

Power supply $id$ on server $[ancestor:compute:RackUnit:id]$ has disconnected cable or bad input voltage

Fault Details

Severity: critical
Cause: power-problem
Type: equipment

cfprFaultInst Offline

Message

Network Module $slotId$ taken offline by user. Please check audit-logs for user activity.

Fault Details

Severity: major
Cause: module-offline
Type: equipment

cfprFaultInst Failed

Message

Network Module in $slotId$ failed to initialize because of an incompatibility. If the correct software is installed, and this module is supported on this hardware, please collect the detailed FPRM techsupport from the local-mgmt shell and contact Cisco.

Fault Details

Severity: critical
Cause: module-failed
Type: equipment

cfprFaultInst Error

Message

Network Module in $slotId$ failed to initialize because of an incompatibility. If the correct software is installed, and this module is supported on this hardware, please collect the detailed FPRM techsupport from the local-mgmt shell and contact Cisco.

Fault Details

Severity: critical
Cause: module-error
Type: equipment

cfprFaultInst OirFailed

Message

Network Module $slotId$ is in failed state. Hot swap with a different type of module is not supported. Please reboot system.

Fault Details

Severity: critical
Cause: module-oir-failed
Type: equipment

cfprFaultInst OirInvalid

Message

Network Module $slotId$ removed. Please re-insert module or use acknowledge command to confirm module removal.

Fault Details

Severity: critical
Cause: module-oir-invalid
Type: equipment

cfprFaultInst Removal

Message

Network Module $slotId$ is in failed state. Hot swap of this type of module is not supported. Please reboot system.

Fault Details

Severity: major
Cause: module-removal
Type: equipment

cfprFaultInst Mismatch

Message

Network Module $slotId$ is of different type than previously inserted module in this slot. Please use acknowledge command to confirm module replacement.

Fault Details

Severity: critical
Cause: module-mismatch
Type: equipment

cfprFaultInst SupriseRemoval

Message

Network Module $slotId$ removed when in online state. It is recommended to set module offline before removal. Please re-insert module or use acknowledge command to confirm module removal.

Fault Details

Severity: critical
Cause: module-surprise-removal
Type: equipment

cfprFaultInst Act2LiteFail

Message

Failed Identification Test in slot - $id$ ($descr$). The module in this slot may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco modules into a Cisco productvis the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program such as SmartNet.

Fault Details

Severity: critical
Cause: act2-fail
Type: equipment

cfprFaultInst CriticalError

Message

Health LED of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ shows error. Reason: $healthLedStateQualifier

Health LED of server $[ancestor:compute:RackUnit:id]$ shows error. Reason: $healthLedStateQualifier$

Fault Details

Severity: critical
Cause: health-led-amber-blinking
Type: equipment

cfprFaultInst SlaveTpm

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$, has a Tpm present on the Slave Board.

Fault Details

Severity: info
Cause: tpm-on-slave-board
Type: equipment

cfprFaultInst MinorError

Message

Health LED of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ shows error. Reason: $healthLedStateQualifier

Health LED of server $[ancestor:compute:RackUnit:id]$ shows error. Reason: $healthLedStateQualifier$

Fault Details

Severity: minor
Cause: health-led-amber
Type: equipment

cfprFaultInst removed

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) is removed

Fault Details

Severity: critical
Cause: equipment-removed
Type: equipment

cfprFaultInst thermalProblem

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) operState: $operState$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst identity

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst cpuThermalThresholdCritical

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) processor temperature exceeded the limit

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst nonSupportedXcvr

Message

The transceiver inserted in port Ethernet $[ancestor:ether:PIo:slotId]$/$[ancestor:ether:PIo:aggrPortId]$/$[ancestor:ether:PIo:portId]$ is not a Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco modules into a Cisco product is the cause of a support issue, Cisco TAC reserves the right to deny support

Fault Details

Severity: minor
Cause: fru-problem
Type: equipment

cfprFaultInst fpgaUpgradeRequired

Message

FPGA version lower than 2.00 is detected. A critical upgrade from the firmware bundle version 1.0.18 or above is required.

Fault Details

Severity: critical
Cause: fpga-upgrade-required
Type: management
 

cfprFaultInst misplacedInChassisSlot

Message

Server, vendor($vendor$), model($model$), serial($serial$) in slot $chassisId$/$slotId$ presence: $presence$.

Fault Details

Severity: warning
Cause: server-moved
Type: equipment

cfprFaultInst serverIdentificationProblem

Message

Problem identifying server in slot $chassisId$/$slotId$

Fault Details

Severity: warning
Cause: server-identification-problem
Type: equipment

cfprFaultInst bladeDecommissionFail

Message

Service Module $slotId$ - Decommission failed, reason: $failReason$

Fault Details

Severity: critical
Cause: decommission-fail
Type: equipment

cfprFaultInst PrimaryVlanMissingForIsolated

Message

Primary Vlan can not be resolved for isolated vlan $name$

Fault Details

Severity: minor
Cause: primary-vlan-missing-for-isolated
Type: network

cfprFaultInst PrimaryVlanMissingForCommunity

Message

Primary Vlan can not be resolved for community vlan $name$

Fault Details

Severity: minor
Cause: primary-vlan-missing-for-community
Type: network

cfprFaultInst empty

Message

LAN Pin Group $name$ is empty

Fault Details

Severity: minor
Cause: empty-pin-group
Type: server

cfprFaultInst down

Message

$[ancestor:fabric:EthLan:type]$ Member $slotId$/$aggrPortId$/$portId$ of Port-Channel $[ancestor:fabric:EthLanPc:portId]$ on fabric interconnect $[ancestor:fabric:EthLan:id]$ is down, membership: $membership$

$[ancestor:fabric:EthLan:type]$ Member $slotId$/$portId$ of Port-Channel $[ancestor:fabric:EthLanPc:portId]$ on fabric interconnect $[ancestor:fabric:EthLan:id]$ is down, membership: $membership$

Fault Details

Severity: major
Cause: membership-down
Type: network

cfprFaultInst down

Message

$[ancestor:fabric:EthEstc:type]$ Member $slotId$/$aggrPortId$/$portId$ of Port-Channel $[ancestor:fabric:EthEstcPc:portId]$ on fabric interconnect $[ancestor:fabric:EthEstc:id]$ is down, membership: $membership$

$[ancestor:fabric:EthEstc:type]$ Member $slotId$/$portId$ of Port-Channel $[ancestor:fabric:EthEstcPc:portId]$ on fabric interconnect $[ancestor:fabric:EthEstc:id]$ is down, membership: $membership$

Fault Details

Severity: major
Cause: membership-down
Type: network

cfprFaultInst down

Message

Pin target is a non-existent interface

Fault Details

Severity: warning
Cause: invalid-target
Type: network

cfprFaultInst down

Message

$[ancestor:fabric:DceSwSrv:type]$ Member $slotId$/$aggrPortId$/$portId$ of Port-Channel $[ancestor:fabric:DceSwSrvPc:portId]$ on fabric interconnect $[ancestor:fabric:DceSwSrv:id]$ is down, membership: $membership$

$[ancestor:fabric:DceSwSrv:type]$ Member $slotId$/$portId$ of Port-Channel $[ancestor:fabric:DceSwSrvPc:portId]$ on fabric interconnect $[ancestor:fabric:DceSwSrv:id]$ is down, membership: $membership$

Fault Details

Severity: major
Cause: membership-down
Type: network

cfprFaultInst spanConfigFail

Message

Configuration for traffic monitor $name$ failed, reason: $configFailReason$

Fault Details

Severity: major
Cause: config-error
Type: network

cfprFaultInst epTransModeFail

Message

Port constraint violation on switch $id$: $confQual$

Fault Details

Severity: critical
Cause: config-error
Type: network

cfprFaultInst mismatch-a

Message

VLAN $name$ has $overlapStateForA$ with another vlan under lan-cloud/appliance-cloud for the fabric interconnect A

Fault Details

Severity: major
Cause: vlan-mismatch
Type: network

cfprFaultInst mismatch-b

Message

VLAN $name$ has $overlapStateForB$ with another vlan under lan-cloud/appliance-cloud for the fabric interconnect B

Fault Details

Severity: major
Cause: vlan-mismatch
Type: network

cfprFaultInst errorAssocPrimary

Message

VLAN $name$ is in error state because the associated primary vlan $assocPrimaryVlanState$

Fault Details

Severity: major
Cause: vlan-error-assoc-primary
Type: network

cfprFaultInst errorMisconfigured

Message

Interface $name$ is $operState$. Reason: $operStateReason$

Fault Details

Severity: critical
Cause: interface-misconfigured
Type: network

cfprFaultInst missingPrimaryVlan

Message

Primary vlan missing from fabric: $switchId$, port: $slotId$/$aggrPortId$/$portId$.

Primary vlan missing from fabric: $switchId$, port: $slotId$/$portId$.

Fault Details

Severity: major
Cause: missing-primary-vlan
Type: management

cfprFaultInst udldLinkDown

Message

UDLD state for ether port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $switchId$ is: $udldOperState$.

UDLD state for ether port $slotId$/$portId$ on fabric interconnect $switchId$ is: $udldOperState$.

Fault Details

Severity: warning
Cause: udld-link-down
Type: network

cfprFaultInst missingPrimaryVlan

Message

Primary vlan missing from fabric: $switchId$, port-channel: $portId$.

Fault Details

Severity: major
Cause: missing-primary-vlan
Type: management

cfprFaultInst overlapping-vlan

Message

On Fabric: $switchId$, Port: $slotId$/$aggrPortId$/$portId$ following overlapping VLANs detected: $overlappingVlans$

On Fabric: $switchId$, Port: $slotId$/$portId$ following overlapping VLANs detected: $overlappingVlans$

Fault Details

Severity: info
Cause: configuration-error
Type: network

cfprFaultInst overlapping-vlan

Message

Overlapping VLANs detected on Fabric: $switchId$, Port: $portId$ in configured VLANs: $overlappingVlans$

Fault Details

Severity: info
Cause: configuration-error
Type: network

cfprFaultInst misconfigured-mcast-policy

Message

VLAN $name$ multicast policy $mcastPolicyName$ is non-default.

Fault Details

Severity: major
Cause: vlan-mcast-policy-misconfigured
Type: network

cfprFaultInst NamedVlanUnresolved

Message

VLAN $name$ for VLAN group $[ancestor:fabric:NetGroup:name]$ cannot be resolved to any existing vlans.

Fault Details

Severity: warning
Cause: named-vlan-unresolved
Type: network

cfprFaultInst DelAllSessEnabled

Message

Packet Capture Session $name$ was still enabled when delete-all-sessions was issued

Fault Details

Severity: warning
Cause: config-error
Type: network

cfprFaultInst failed

Message

Service profile $name$ failed

Fault Details

Severity: major
Cause: server-failed
Type: server

cfprFaultInst discoveryFailed

Message

Service profile $name$ discovery failed

Fault Details

Severity: major
Cause: discovery-failed
Type: server

cfprFaultInst configFailure

Message

Service profile $name$ configuration failed due to $configQualifier$

Fault Details

Severity: major
Cause: configuration-failure
Type: server

cfprFaultInst maintenanceFailed

Message

Service profile $name$ maintenance failed

Fault Details

Severity: major
Cause: maintanence-failed
Type: server

cfprFaultInst removed

Message

Service profile $name$ underlying resource removed

Fault Details

Severity: major
Cause: equipment-removed
Type: server

cfprFaultInst inaccessible

Message

Service profile $name$ cannot be accessed

Fault Details

Severity: major
Cause: server-inaccessible
Type: server

cfprFaultInst associationFailed

Message

Service profile $name$ association failed for $pnDn$

Fault Details

Severity: major
Cause: association-failed
Type: server

cfprFaultInst assignmentRequirementsNotMet

Message

Assignment of service profile $[ancestor:ls:Server:name]$ to server $pnDn$ failed

Fault Details

Severity: minor
Cause: assignment-failed
Type: server

cfprFaultInst unassociated

Message

Service profile $name$ is not associated

Fault Details

Severity: warning
Cause: unassociated
Type: server

cfprFaultInst svnicNotPresent

Message

Service profile $name$ does not contain service vnics for netflow.

Fault Details

Severity: warning
Cause: svnic-not-present
Type: server

cfprFaultInst server-unfulfilled

Message

Server $pnDn$ does not fulfill Service profile $name$ due to $configQualifier$

Fault Details

Severity: warning
Cause: server-failed
Type: server

cfprFaultInst unresolvableScheduler

Message

Schedule $schedName$ referenced by maintenance policy $name$ does not exist

Fault Details

Severity: warning
Cause: non-existent-scheduler
Type: server

cfprFaultInst kvmPolicyUnsupported

Message

Kvm mgmt policy not supported by current CIMC version

Fault Details

Severity: minor
Cause: unsupported-cimc-firmware
Type: server

cfprFaultInst inoperable

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst degraded

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: warning
Cause: equipment-degraded
Type: equipment

cfprFaultInst unusable

Message

Local disk $id$ on server $[ancestor:compute:Physical:serverId]$ is not usable by the operating system

Fault Details

Severity: minor
Cause: equipment-inoperable
Type: equipment

cfprFaultInst capacityExceeded

Message

Disk usage for partition $name$ on fabric interconnect $[ancestor:network:Element:id]$ exceeded 70%

Fault Details

Severity: minor
Cause: capacity-exceeded
Type: environmental

cfprFaultInst capacityWarning

Message

Disk usage for partition $name$ on fabric interconnect $[ancestor:network:Element:id]$ exceeded 90%

Fault Details

Severity: critical
Cause: capacity-exceeded
Type: environmental

cfprFaultInst filesystemIssues

Message

Partition $name$ on fabric interconnect $[ancestor:network:Element:id]$ has file system errors

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst configuration-error

Message

Flash Life on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ flashStatus: $flashStatus$

Fault Details

Severity: info
Cause: configuration-error
Type: equipment

cfprFaultInst degraded

Message

Flash Life on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ flashStatus: $flashStatus$

Fault Details

Severity: warning
Cause: equipment-degraded
Type: equipment

cfprFaultInst degraded

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst relearnAborted

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst relearnFailed

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst configuration-error

Message

Initiator $name$ either cannot be resolved or does not match with one of the storage targets. No zones are deployed for this initiator and the target.

Fault Details

Severity: warning
Cause: configuration-error
Type: equipment

cfprFaultInst patrolReadFailed

Message

Controller $id$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ had a patrol read failure. Reason: $operQualifierReason$

Controller $id$ on server $[ancestor:compute:RackUnit:id]$ had a patrol read failure. Reason: $operQualifierReason$

Fault Details

Severity: warning
Cause: operation-failed
Type: equipment

cfprFaultInst inoperable

Message

Controller $id$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $operQualifierReason$

Controller $id$ on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $operQualifierReason$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst rebuildFailed

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-offline
Type: equipment

cfprFaultInst copybackFailed

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-offline
Type: equipment

cfprFaultInst missing

Message

Local disk $id$ missing on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Local disk $id$ missing on server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: major
Cause: equipment-missing
Type: equipment

cfprFaultInst inoperable

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst degraded

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst reconstructionFailed

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst consistencyCheckFailed

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

FlexFlash Controller $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $operQualifierReason$ Status: $controllerHealth$

FlexFlash Controller $id$ on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $operQualifierReason$ Status: $controllerHealth$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst inoperable

Message

FlexFlash Card $slotNumber$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $operQualifierReason$

FlexFlash Card $slotNumber$ on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst missing

Message

FlexFlash Card $slotNumber$ missing on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

FlexFlash Card $slotNumber$ missing on server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: info
Cause: equipment-missing
Type: equipment

cfprFaultInst degraded

Message

FlexFlash Virtual Drive RAID degraded on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$. Reason: $raidState$

FlexFlash Virtual Drive RAID degraded on server $[ancestor:compute:RackUnit:id]$. Reason: $raidState$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

FlexFlash Virtual Drive on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $raidState$

FlexFlash Virtual Drive on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $raidState$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst mismatch

Message

FlexFlash Controller $id$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ has SD cards with different sizes.

FlexFlash Controller $id$ on server $[ancestor:compute:RackUnit:id]$ has SD cards with different sizes.

Fault Details

Severity: major
Cause: equipment-unhealthy
Type: equipment

cfprFaultInst unhealthy

Message

FlexFlash Drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is unhealthy. Reason: $operQualifierReason$ Status: $operationState$

FlexFlash Drive $id$ on server $[ancestor:compute:RackUnit:id]$ is unhealthy. Reason: $operQualifierReason$ Status: $operationState$

Fault Details

Severity: major
Cause: equipment-unhealthy
Type: equipment

cfprFaultInst unhealthy

Message

FlexFlash Card $slotNumber$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is unhealthy. Reason: $cardHealth$

FlexFlash Card $slotNumber$ on server $[ancestor:compute:RackUnit:id]$ is unhealthy. Reason: $cardHealth$

Fault Details

Severity: minor
Cause: equipment-unhealthy
Type: equipment

cfprFaultInst degraded

Message

Fabric Interconnect $id$, HA Cluster interconnect link failure

Fault Details

Severity: major
Cause: link-down
Type: network

cfprFaultInst down

Message

Fabric Interconnect $id$, HA Cluster interconnect total link failure

Fault Details

Severity: critical
Cause: link-down
Type: network

cfprFaultInst election-failure

Message

Fabric Interconnect $id$, election of primary managemt instance has failed

Fault Details

Severity: critical
Cause: election-failure
Type: management

cfprFaultInst management-services-failure

Message

Fabric Interconnect $id$, management services have failed

Fault Details

Severity: critical
Cause: management-services-failure
Type: management

cfprFaultInst management-services-unresponsive

Message

Fabric Interconnect $id$, management services are unresponsive

Fault Details

Severity: critical
Cause: management-services-unresponsive
Type: management

cfprFaultInst ha-not-ready

Message

Fabric Interconnect $id$, HA functionality not ready

Fault Details

Severity: major
Cause: ha-not-ready
Type: management

cfprFaultInst version-incompatible

Message

Fabric Interconnect $id$, management services, incompatible versions

Fault Details

Severity: critical
Cause: version-incompatible
Type: management

cfprFaultInst device-1-shared-storage-error

Message

device $chassis1$, error accessing shared-storage

Fault Details

Severity: warning
Cause: device-shared-storage-error
Type: management

cfprFaultInst device-2-shared-storage error

Message

device $chassis2$, error accessing shared-storage

Fault Details

Severity: warning
Cause: device-shared-storage-error
Type: management

cfprFaultInst device-3-shared-storage-error

Message

device $chassis3$, error accessing shared-storage

Fault Details

Severity: warning
Cause: device-shared-storage-error
Type: management

cfprFaultInst ha-ssh-keys-mismatched

Message

Fabric Interconnect $id$, management services, mismatched SSH keys

Fault Details

Severity: major
Cause: ha-ssh-keys-mismatched
Type: management

cfprFaultInst FPRM process failure

Message

FPRM process $name$ failed on FI $switchId$

Fault Details

Severity: critical
Cause: FPRM process failure
Type: management

cfprFaultInst mEpLogLog

Message

Log capacity on $[ancestor:equipment:IOCard:side]$ IOM $[ancestor:equipment:IOCard:chassisId]$/$[ancestor:equipment:IOCard:id]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:RackUnit:id]$ is $capacity$

Fault Details

Severity: info
Cause: log-capacity
Type: operational

cfprFaultInst mEpLogVeryLow

Message

Log capacity on $[ancestor:equipment:IOCard:side]$ IOM $[ancestor:equipment:IOCard:chassisId]$/$[ancestor:equipment:IOCard:id]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:RackUnit:id]$ is $capacity$

Fault Details

Severity: info
Cause: log-capacity
Type: operational

cfprFaultInst mEpLogFull

Message

Log capacity on $[ancestor:equipment:IOCard:side]$ IOM $[ancestor:equipment:IOCard:chassisId]$/$[ancestor:equipment:IOCard:id]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:RackUnit:id]$ is $capacity$

Fault Details

Severity: info
Cause: log-capacity
Type: operational

cfprFaultInst transferError

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ $type$ transfer failed: $operState$

Server $[ancestor:compute:RackUnit:id]$ $type$ transfer failed: $operState$

Fault Details

Severity: info
Cause: file-transfer-failed
Type: operational

cfprFaultInst MisConnect

Message

Management Port $id$ in server $[ancestor:compute:RackUnit:id]$ is mis connected

Fault Details

Severity: warning
Cause: link-misconnected
Type: operational

cfprFaultInst Missing

Message

Connection to Management Port $id$ in server $[ancestor:compute:RackUnit:id]$ is missing

Fault Details

Severity: warning
Cause: link-missinglink-missing
Type: operational

cfprFaultInst New

Message

New connection discovered on Management Port $id$ in server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: warning
Cause: new-link
Type: operational

cfprFaultInst disabled

Message

Management Connection $type$ in server $[ancestor:compute:RackUnit:id]$ is not operational

Fault Details

Severity: warning
Cause: another-connection-already-enabled
Type: operational

cfprFaultInst unused

Message

Management Connection $type$ in server $[ancestor:compute:RackUnit:id]$ is unused

Fault Details

Severity: info
Cause: connection-unused
Type: operational

cfprFaultInst unsupportedConnectivity

Message

Unsupported connectivity for management connection $type$ in server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: minor
Cause: unsupported-connectivity
Type: operational

cfprFaultInst unsupportedDimmBlacklisting

Message

Dimm blacklisting is not supported on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Dimm blacklisting is not supported on server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: info
Cause: incompatible-server-firmware
Type: environmental

cfprFaultInst namedInbandVlanUnresolved

Message

$configMessage$

Fault Details

Severity: minor
Cause: named-inband-vlan-unresolved
Type: management

cfprFaultInst inbandUnsupportedServer

Message

$configMessage$

Fault Details

Severity: minor
Cause: inband-unsupported-server
Type: management

cfprFaultInst inbandUnsupportedFirmware

Message

$configMessage$

Fault Details

Severity: minor
Cause: unsupported-cimc-firmware
Type: management

cfprFaultInst Configuration backup outdated

Message

Config backup may be outdated

Fault Details

Severity: minor
Cause: config backup outdated
Type: management

cfprFaultInst Configuration import failed

Message

Importing configuration failed: $errMsg

Fault Details

Severity: major
Cause: config import failed
Type: management

cfprFaultInst processRestarted

Message

Process $name$ got terminated with exit signal $exitSignal$ and restarted $retries$ times

Fault Details

Severity: warning
Cause: process-terminated
Type: management

cfprFaultInst loadErrors

Message

Load errors: File parse errors: $fileParseFailures$, provider load failures: $providerLoadFailures$, XML element load errors: $loadErrors$.

Fault Details

Severity: major
Cause: load-catalog-failed
Type: management

cfprFaultInst NoSnmpPolicyForCallhome

Message

FPR Manager cannot apply Callhome policy if SNMP Policy is not configured or if SNMP Syscontact has an empty value. The Callhome policy from FPR Central has not been applied.

Fault Details

Severity: minor
Cause: callhome-config-error
Type: configuration

cfprFaultInst linkState

Message

Virtual interface $id$ link state is down

Fault Details

Severity: major
Cause: vif-down
Type: management

cfprFaultInst mgmtifdown

Message

$failureReason$

Fault Details

Severity: major
Cause: mgmtif-down
Type: management

cfprFaultInst ArpTargetsNotValid

Message

Invalid ARP Targets configured for Management Interface Polling. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: arp-targets-config-error
Type: management

cfprFaultInst NdiscTargetsNotValid

Message

Invalid NDISC Targets configured for Management Interface Polling. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: ndisc-targets-config-error
Type: management

cfprFaultInst gracePeriodWarning

Message

FPR domain $name$ registered with FPR Central has entered into the grace period.

Fault Details

Severity: warning
Cause: license-graceperiod-entered
Type: management

cfprFaultInst gracePeriodWarning2

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 10 days

Fault Details

Severity: warning
Cause: license-graceperiod-10days
Type: management

cfprFaultInst gracePeriodWarning3

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 30 days

Fault Details

Severity: warning
Cause: license-graceperiod-30days
Type: management

cfprFaultInst gracePeriodWarning4

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 60 days

Fault Details

Severity: warning
Cause: license-graceperiod-60days
Type: management

cfprFaultInst gracePeriodWarning5

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 90 days

Fault Details

Severity: major
Cause: license-graceperiod-90days
Type: management

cfprFaultInst gracePeriodWarning6

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 119 days

Fault Details

Severity: critical
Cause: license-graceperiod-119days
Type: management

cfprFaultInst gracePeriodWarning7

Message

Grace period for FPR Domain $name$ registered with FPR Central has expired. Please acquire a license for the same.

Fault Details

Severity: critical
Cause: license-graceperiod-expired
Type: management

cfprFaultInst gracePeriodWarning1

Message

FPR Domain $name$ is registered with FPR Central without a valid license.

Fault Details

Severity: critical
Cause: license-insufficient
Type: management

cfprFaultInst linkState

Message

Virtual interface $vifId$ link is down; reason $stateQual$

Fault Details

Severity: minor
Cause: vif-down
Type: management

cfprFaultInst vmNetworkReferenceIncorrect

Message

VM Network $[ancestor:extvmm:VMNetwork:name]$ references $vmNetworkDefName$ that is already being referenced by another VM Network

Fault Details

Severity: warning
Cause: vm-network-reference-incorrect
Type: management

cfprFaultInst empty

Message

FC pool $purpose$ $name$ is empty

Fault Details

Severity: minor
Cause: empty-poolt
Type: server

cfprFaultInst imageMissing

Message

$type$ image with vendor $hwVendor$, model $hwModel$ and version $version$ is deleted

Fault Details

Severity: major
Cause: image-deleted
Type: management

cfprFaultInst imageUnusable

Message

backup image is unusable. reason: $operStateQual$

Fault Details

Severity: major
Cause: image-unusable
Type: management

cfprFaultInst cantBoot

Message

unable to boot the startup image. End point booted with backup image

Fault Details

Severity: major
Cause: image-cannot-boot
Type: management

cfprFaultInst activateStatusFailed

Message

Activation failed and Activate Status set to failed.

Fault Details

Severity: major
Cause: activation-failed
Type: management

cfprFaultInst cimcFirmwareMismatch

Message

Aggregate blade CIMC firmware mismatch. Firmware: $cimcVersion$

Fault Details

Severity: critical
Cause: cimc-firmware-mismatch
Type: management

cfprFaultInst pldFirmwareMismatch

Message

Aggregate blade board controller firmware mismatch. Firmware: $pldVersion$

Fault Details

Severity: critical
Cause: pld-firmware-mismatch
Type: management

cfprFaultInst defaultHostPackageMissing

Message

Default host firmware package is missing or deleted.

Fault Details

Severity: major
Cause: defaultHostpackMissing
Type: management

cfprFaultInst bundleVersionMissing

Message

Platform version is empty in platform firmware package

Fault Details

Severity: critical
Cause: defaultPlaformVersionMissing
Type: management

cfprFaultInst adapterUpgradeRequired

Message

Adapter $[ancestor:adaptor:Unit:id]$ on Security Module $[ancestor:compute:Blade:slotId]$ requires a critical firmware upgrade. Please see Adapter Bootloader Upgrade instructions in the FXOS Release Notes posted with this release.

Fault Details

Severity: critical
Cause: adapter-boot-upgrade-required
Type: management

cfprFaultInst ImageVersionMismatch

Message

Mismatched $mismatchType$ image version $[ancestor:firmware:Running:version]$ detected. Expected version $installedImageVersion$ from FXOS $installedPackageVersion$.

Fault Details

Severity: major
Cause: image-version-mismatch
Type: management

cfprFaultInst ImageVersionMismatch

Message

Mismatch in Running and Startup image Version detected, activation required

Fault Details

Severity: major
Cause: image-version-mismatch
Type: management

cfprFaultInst ImageVersionMismatch

Message

Mismatch in Manager image Running and Startup Version detected

Fault Details

Severity: major
Cause: image-version-mismatch
Type: management

cfprFaultInst unidentifiable-fru

Message

Adapter $id$ in server $[ancestor:compute:RackUnit:id]$ has unidentified FRU

Adapter $id$ in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has unidentified FRU

Fault Details

Severity: major
Cause: unidentifiable-fru
Type: server

cfprFaultInst unidentifiable-fru

Message

Adapter extension $id$ in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has unidentified FRU

Fault Details

Severity: major
Cause: unidentifiable-fru
Type: server

cfprFaultInst missing

Message

Adapter $id$ in server $[ancestor:compute:RackUnit:id]$ presence: $presence$

Adapter $id$ in server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ presence: $presence$

Fault Details

Severity: warning
Cause: equipment-missing
Type: equipment

cfprFaultInst missing

Message

Adapter extension $id$ in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ presence: $presence$

Fault Details

Severity: warning
Cause: equipment-missing
Type: equipment

cfprFaultInst AdaptorReachability

Message

Adapter $[ancestor:compute:RackUnit:id]$/$id$ is unreachable

Adapter $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$/$id$ is unreachable

Fault Details

Severity: info
Cause: connectivity-problem
Type: connectivity

cfprFaultInst link-down

Message

Adapter $transport$ host interface $[ancestor:compute:RackUnit:id]$/$[ancestor:adaptor:Unit:id]$/$id$ link state: $linkState$, Associated external interface link state: $vcAdminState$

Adapter $transport$ host interface $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$/$[ancestor:adaptor:Unit:id]$/$id$ link state: $linkState$, Associated external interface link state: $vcAdminState$

Fault Details

Severity: major
Cause: link-down
Type: network

cfprFaultInst link-down

Message

Adapter uplink interface $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$/$[ancestor:adaptor:Unit:id]$/$id$ on security module $[ancestor:compute:Blade:slotId]$ link state: $linkState$. Please check switch blade-facing port status. Resetting security module might be required.

Fault Details

Severity: critical
Cause: link-down
Type: network

cfprFaultInst MisConnect

Message

Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ mis-connected

Fault Details

Severity: warning
Cause: link-misconnected
Type: network

cfprFaultInst Missing

Message

Connection to Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ missing

Fault Details

Severity: warning
Cause: link-missing
Type: network

cfprFaultInst MisConnect

Message

Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ mis-connected

Fault Details

Severity: warning
Cause: link-misconnected
Type: network

cfprFaultInst Missing

Message

Connection to Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ missing

Fault Details

Severity: warning
Cause: link-missing
Type: network

cfprFaultInst empty

Message

IP pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst empty

Message

iqn pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst empty

Message

MAC pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst degraded

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst server-bad-memorry

Message

Physical memory size $currCapacity$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is smaller than expected.

Physical memory size $currCapacity$ on server $[ancestor:compute:RackUnit:id]$ is smaller than expected.

Fault Details

Severity: major
Cause: bad-memory-detect
Type: equipment

cfprFaultInst inoperable

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: major
Cause: equiment-inoperable
Type: equipment

cfprFaultInst disabled

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operState: $operState$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ operaState: $operState$

Fault Details

Severity: major
Cause: equipment-disabled
Type: equipment

cfprFaultInst thermalThresholdNonCritical

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: info
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Buffer Unit $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Buffer Unit $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: info
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Buffer Unit $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Buffer Unit $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Buffer Unit $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Buffer Unit $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Memory array $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Memory array $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Memory array $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Memory array $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Memory array $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Memory array $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: critical
Cause: voltage-problem
Type: environmental

cfprFaultInst inoperable

Message

Fabric Interconnect $id$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst removed

Message

Fabric Interconnect $id$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-removed
Type: equipment

cfprFaultInst samconfig

Message

The Supervisor's sam.config file stored in the /opt partition is not accessible

Fault Details

Severity: critical
Cause: file-missing
Type: configuration

cfprFaultInst resourceStatus

Message

Vlan-Port Resource exceeded

Fault Details

Severity: critical
Cause: limit-reached
Type: management

cfprFaultInst resourceStatusWarning

Message

Total Available Vlan-Port Count on switch $switchId$ is below 10%

Fault Details

Severity: warning
Cause: near-max-limit
Type: management

cfprFaultInst inventoryFailed

Message

Fabric Interconnect $id$ inventory is not complete $inventoryStatus$

Fault Details

Severity: major
Cause: inventory-failed
Type: equipment

cfprFaultInst thermalThresholdCritical

Message

Fabric Interconnect $id$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst memoryerror

Message

Fabric Interconnect $id$ memory less than expected! Total Memory: $totalMemory$ and Expected Memory: $expectedMemory$

Fault Details

Severity: major
Cause: memory-error
Type: equipment

cfprFaultInst extraprimaryvlans

Message

Fabric Interconnect $id$: Number of primary vlans exceeds the max limit on the FI: Number of Primary Vlans: $primaryVlanCount$ and Max primary vlans allowed: $maxPrimaryVlanCount$

Fault Details

Severity: major
Cause: extra-primary-vlans
Type: equipment

cfprFaultInst extrasecondaryvlans

Message

Fabric Interconnect $id$: Number of secondary vlans exceeds the max limit on the FI: Number of secondary vlans: $secondaryVlanCount$ and Max secondary vlans allowed: $maxSecondaryVlanCount$

Fault Details

Severity: major
Cause: extra-secondary-vlans
Type: equipment

cfprFaultInst extrasecondaryvlansperprimary

Message

Number of secondary vlans associated with the primary vlan $id$ in Fabric Interconnect $switchId$ exceeds the max limit: Number of secondary vlans: $secVlanPerPrimaryVlanCount$ and Max secondary vlans allowed in a primary vlan: 30

Fault Details

Severity: minor
Cause: extra-secondary-vlans-per-primary
Type: equipment

cfprFaultInst failedBladeBootup

Message

Slot $slotId$, boot up failed - recovery in progress

Fault Details

Severity: major
Cause: bootup-failure
Type: server

cfprFaultInst failedBootupRecovery

Message

Slot $slotId$, boot up failed - exceeded max number of retrie

Fault Details

Severity: major
Cause: bootup-failure
Type: server

cfprFaultInst suspendModeActive

Message

FPRM is suspended from receiving updates from FPR Central.

Fault Details

Severity: warning
Cause: suspend-mode-entered
Type: management

cfprFaultInst duplicatedAssigned

Message

ID is duplicated assigned for multiple servers(Check FPRC for details)

Fault Details

Severity: major
Cause: duplicated-assigned
Type: server

cfprFaultInst link-down

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: link-down
Type: network

cfprFaultInst failed

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: port-failed
Type: network

cfprFaultInst hardware-failure

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: hardware-failure

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: hardware-failure

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: hardware-failure

Fault Details

Severity: major
Cause: port-failed
Type: network

cfprFaultInst sfp-not-present

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$

Fault Details

Severity: info
Cause: port-failed
Type: network

fprFaultInst invalid-sfp

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ role : $ifRole$ transceiver type:$xcvrType$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ role : $ifRole$ transceiver type:$xcvrType$$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ role : $ifRole$ transceiver type:$xcvrType$$

Fault Details

Severity: major
Cause: unsupported-transceiver
Type: network

cfprFaultInst hardware-failure

Message

IOM $transport$ interface $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: $stateQual$

Fabric Interconnect $transport$ interface $portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

IOM $transport$ interface $portId$ on fex $[ancestor:equipment:Fex:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: interface-failed
Type: network

cfprFaultInst down

Message

$type$ port-channel $portId$ on fabric interconnect $switchId$ oper state: $operState$, reason: $stateQual$

$type$ port-channel $portId$ on fabric interconnect $switchId$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: operational-state-down
Type: network

cfprFaultInst down

Message

$[ancestor:fabric:DceSwSrv:type]$ port-channel $portId$ on fabric interconnect $[ancestor:fabric:DceSwSrv:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: operational-state-down
Type: network

cfprFaultInst down

Message

$transport$ VIF $id$ on server $[ancestor:fabric:Locale:chassisId]$ / $[ancestor:compute:Blade:slotId]$ of switch $switchId$ down, reason: $stateQual$

$transport$ VIF $id$ on server $[ancestor:compute:RackUnit:id]$ of switch $switchId$ down, reason: $stateQual$

Fault Details

Severity: major
Cause: link-down
Type: network

cfprFaultInst mgmt-vif-down

Message

IOM $[ancestor:fabric:Locale:chassisId]$ / $[ancestor:fabric:Locale:slotId]$ ($switchId$) management VIF $id$ down, reason $stateQual$

Fault Details

Severity: major
Cause: cmc-vif-down
Type: network

cfprFaultInst PowerGroupCapInsufficient

Message

Chassis $id$ cannot be capped as group cap is low. Please consider raising the cap.

Fault Details

Severity: major
Cause: group-cap-insufficient
Type: environmental

cfprFaultInst ChassisFirmwareProblem

Message

Chassis $id$ cannot be capped as at least one of the CMC or CIMC or BIOS firmware version is less than 1.4. Please upgrade the firmware for cap to be applied.

Fault Details

Severity: major
Cause: old-chassis-component-firmware
Type: environmental

cfprFaultInst ChassisPsuInsufficient

Message

Chassis $id$ cannot be capped as at least two PSU need to be powered

Fault Details

Severity: major
Cause: psu-insufficient
Type: environmental

cfprFaultInst ChassisPsuInsufficient

Message

Chassis $[ancestor:equipment:Chassis:id]$ cannot be capped as the available PSU power is not enough for the chassis and the blades. Please correct the problem by checking input power or replace the PSU

Fault Details

Severity: major
Cause: psu-insufficient
Type: environmental

cfprFaultInst ChassisPsuRedundanceFailure

Message

Chassis $id$ was configured for redundancy, but running in a non-redundant configuration.

Fault Details

Severity: major
Cause: psu-redundancy-fail
Type: environmental

cfprFaultInst PowerBudgetCmcProblem

Message

Power cap application failed for chassis $[ancestor:equipment:Chassis:id]$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerBudgetBmcProblem

Message

Power cap application failed for server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Power cap application failed for server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerCapReachedCommit

Message

P-State lowered as consumption hit power cap for server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

P-State lowered as consumption hit power cap for server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: info
Cause: power-consumption-hit-limit
Type: environmental

cfprFaultInst TStateTransition

Message

Blade $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant

Rack server $[ancestor:compute:RackUnit:id]$ has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant

Fault Details

Severity: critical
Cause: no-ack-from-bios
Type: environmental

cfprFaultInst PowerBudgetDiscFail

Message

Insufficient power available to discover server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Insufficient power available to discover server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: critical
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerPolicyApplicationFail

Message

Insufficient budget to apply no-cap priority through policy $name$. Blades will continue to be capped

Fault Details

Severity: minor
Cause: no-cap-fail
Type: environmental

cfprFaultInst PowerGroupInsufficientBudget

Message

insufficient budget for power group $name$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerGroupBudgetIncorrect

Message

admin committed insufficient for power group $name$, using previous value $operCommitted$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst ChassisPsuMixedMode

Message

Chassis $[ancestor:equipment:Chassis:id]$ has a mix of high-line and low-line PSU input power sources.

Fault Details

Severity: critical
Cause: psu-mixed-mode
Type: environmental

cfprFaultInst inoperable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst thermalNonCritical

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: info
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalCriticalThreshold

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst voltageThresholdNonCritical

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdCritical

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdNonRecoverable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: critical
Cause: voltage-problem
Type: environmental

cfprFaultInst identity-unestablishable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has an invalid FRU

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ has an invalid FRU

Fault Details

Severity: warning
Cause: identity-unestablishable
Type: equipment

cfprFaultInst disabled

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operState: $operState$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ operState: $operState$

Fault Details

Severity: major
Cause: equipment-disabled
Type: environmental

cfprFaultInst vnicConfigFail

Message

Failed to set the oper state for vnic(s) $failedCfgVnics$.

Fault Details

Severity: major
Cause: vnic-config-failed
Type: server

cfprFaultInst internalMgmtVnicConfigFail

Message

Failed to allocate internal mgmt vnic for application instance $[ancestor:sd:AppInstance:appName]$-$[ancestor:sd:AppInstance:identifier]$ on slot $[ancestor:sd:Slot:slotId]$

Fault Details

Severity: warning
Cause: internal-mgmt-vnic-config-fail
Type: server

cfprFaultInst externalLduLinkVnicConfigFail

Message

Failed to allocate vnic for ExternalLduLink $name$ in LogicalDevice $[ancestor:sd:LogicalDevice:ldName]$(type:$type$) for $appName$ on slot $[ancestor:sd:Ldu:slotId]$

Fault Details

Severity: warning
Cause: external-ldu-link-vnic-config-fail
Type: server

cfprFaultInst appLduLinkEndpoint1VnicConfigFail

Message

Failed to allocate vnic for AppLduLink $name$ in LogicalDevice $[ancestor:sd:LogicalDevice:ldName]$(type:$type$) for $appName$ on slot $[ancestor:sd:Ldu:slotId]$

Fault Details

Severity: warning
Cause: app-ldu-link-endpoint1-vnic-config-fail
Type: server

cfprFaultInst appLduLinkEndpoint2VnicConfigFail

Message

Failed to allocate vnic for AppLduLink $name$ in LogicalDevice $[ancestor:sd:LogicalDevice:ldName]$(type:$type$) for main app on slot $[ancestor:sd:Ldu:slotId]$

Fault Details

Severity: warning
Cause: app-ldu-link-endpoint2-vnic-config-fail
Type: server

cfprFaultInst vnicPreAllocationFail

Message

Failed to pre-allocate vnic for application instance $[ancestor:sd:AppInstance:appName]$-$[ancestor:sd:AppInstance:identifier]$ on slot $[ancestor:sd:AppInstance:slotId]$ (type:$portType$)

Fault Details

Severity: warning
Cause: vnic-preAllocation-fail
Type: server

cfprFaultInst differentResourcesInProfile

Message

$resourceFaultMsg$

Fault Details

Severity: warning
Cause: different-resources-in-profile
Type: server

cfprFaultInst providergroup

Message

For $dn$: Server Group with name $name$ already exist, You need to specify a unique name for this object.

Fault Details

Severity: major
Cause: provider-group-already-exists
Type: security

cfprFaultInst providergroupsize

Message

For $dn$: Server Group $name$ has $size$ provider references. Authentication might fail, if this provider group is used with auth-domain.

Fault Details

Severity: warning
Cause: provider-group-size-empty
Type: security

cfprFaultInst servergroup

Message

For $dn$: $realm$ Server Group with name $providerGroup$ doesn't exist or is not deployed.

Fault Details

Severity: critical
Cause: invalid-server-group
Type: security

cfprFaultInst status

Message

$name$ Keyring's certificate is invalid, reason: $certStatus$.

Fault Details

Severity: major
Cause: invalid-Keyring-certificate
Type: security

cfprFaultInst tp-auto-import-failure

Message

TrustPoints Auto Import Failure.

Fault Details

Severity: warning
Cause: invalid-tp-auto-import
Type: security

cfprFaultInst tp-auto-import-attempt

Message

Last TrustPoints Auto Import Attempt.

Fault Details

Severity: info
Cause: tp-auto-import
Type: security

cfprFaultInst modulus

Message

$name$ Keyring's RSA modulus is invalid.

Fault Details

Severity: major
Cause: invalid-Keyring-modulus
Type: security

cfprFaultInst ec

Message

$name$ Keyring's ECDSA elliptic-curve is invalid.

Fault Details

Severity: major
Cause: invalid-Keyring-ec
Type: security

cfprFaultInst status

Message

$name$ Trustpoint's cert-chain is invalid, reason: $certStatus$.

Fault Details

Severity: major
Cause: invalid-trustpoint-cert-chain
Type: security

cfprFaultInst roleNotDeployed

Message

Role $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: critical
Cause: role-config-error
Type: security

cfprFaultInst localeNotDeployed

Message

Locale $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: critical
Cause: locale-config-error
Type: security

cfprFaultInst localeOrgNotPresent

Message

Locale Org $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: warning
Cause: locale-org-config-error
Type: security

cfprFaultInst userRoleNotDeployed

Message

For user: $[ancestor:aaa:User:name]$ role $name$ can't be assigned. Error: $configStatusMessage$.

For Ldap Group: $[ancestor:aaa:LdapGroup:name]$ role $name$ can't be assigned. Error: $configStatusMessage$.

Fault Details

Severity: critical
Cause: user-role-config-error
Type: security

cfprFaultInst userLocaleNotDeployed

Message

For user: $[ancestor:aaa:User:name]$ locale $name$ can't be assigned. Error: $configStatusMessage$.

For Ldap Group: $[ancestor:aaa:LdapGroup:name]$ locale $name$ can't be assigned. Error: $configStatusMessage$.

Fault Details

Severity: critical
Cause: user-locale-config-error
Type: security

cfprFaultInst KeyRingNotDeployed

Message

Keyring $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: critical
Cause: keyring-config-error
Type: security

cfprFaultInst SyscontactEmpty

Message

FPR Manager cannot deploy an empty value of SNMP Syscontact when Callhome is enabled. The previous value $sysContact$ for SNMP Syscontact has been retained.

Fault Details

Severity: warning
Cause: snmp-config-error
Type: configuration

cfprFaultInst commTimeZoneInvalid

Message

Timezone:$timezone$ is invalid

Fault Details

Severity: minor
Cause: timezone-file-not-exists
Type: configuration

cfprFaultInst TelemetryRegistrationFailed

Message

Auto registration of device for telemetry failed. Error: $errorMessage$

Fault Details

Severity: major
Cause: telemetry-registration-failed
Type: security

cfprFaultInst TelemetryUnregistrationFailed

Message

Failed to unregister the device with the cloud. Error: $errorMessage$

Fault Details

Severity: major
Cause: telemetry-unregistration-failed
Type: security

cfprFaultInst TelemetryGetDataFailed

Message

Failed to get telemetry data from application. Error: $errorMessage$

Fault Details

Severity: major
Cause: Telemetry-get-data-failed
Type: security

cfprFaultInst TelemetrySendDataFailed

Message

Failed to send telemetry data. Error: $errorMessage$

Fault Details

Severity: major
Cause: Telemetry-send-data-failed
Type: security

cfprFaultInst commNtpConfigurationFailed

Message

Ntp Configuration failed, please check the error message in Ntp host

Fault Details

Severity: major
Cause: ntp-config-failed
Type: configuration

cfprFaultInst localUserNotDeployed

Message

Local User $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: user-config-error
Type: security

cfprFaultInst snmpUserNotDeployed

Message

SNMP User $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: snmp-user-config-error
Type: configuration

cfprFaultInst commSvcNotDeployed

Message

Communication Service configuration can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: comm-svc-config-error
Type: configuration

cfprFaultInst ipsecConnInvalidKey

Message

Invalid keyring $keyring$ for IPSec connection $name$

Fault Details

Severity: major
Cause: ipsec-config-error
Type: configuration

cfprFaultInst ipsecConnInvalidCert

Message

Invalid Cert of keyring $keyring$ for IPSec connection $name$

Fault Details

Severity: major
Cause: ipsec-config-error
Type: configuration

cfprFaultInst ipsecAuthorInvalidTp

Message

Invalid trustpoint $tpName$ for IPSec

Fault Details

Severity: major
Cause: ipsec-config-error
Type: configuration

cfprFaultInst passwordEncryptionKeyNotSet

Message

The password encryption key has not been set.

Fault Details

Severity: warning
Cause: password-encryption-key-not-set
Type: configuration

cfprFaultInst SSh3desUsageNotRecommended

Message

Ssh-server is configured with 3des as encrypt alogrithm. 3des is deprecated and the usage is disallowed after 2023.

Fault Details

Severity: warning
Cause: ssh-3des-usage-not-recommended
Type: configuration

cfprFaultInst Sshc3desUsageNotRecommended

Message

Ssh-client is configured with 3des as encrypt alogrithm. 3des is deprecated and the usage is disallowed after 2023.

Fault Details

Severity: warning
Cause: ssh-3des-usage-not-recommended
Type: configuration

cfprFaultInst smaHeartbeat

Message

Security module $slotId$ - network adapter 1 is not responding

Fault Details

Severity: major
Cause: slot-not-responding
Type: server

cfprFaultInst bladeNotWorking

Message

Security Module $slotId$ is in failed state. Error: $errorMsg$

Fault Details

Severity: major
Cause: blade-not-working
Type: server

cfprFaultInst adapter2NotResponding

Message

$errorMsg$

Fault Details

Severity: major
Cause: adapter-2-not-responding
Type: server

cfprFaultInst platformNotSupported

Message

Security Module Discovery failed in slot $slotId$. The running FXOS version does not support the platform; The final supported version is 2.12.

Fault Details

Severity: major
Cause: platform-not-supported
Type: server

cfprFaultInst moduleNotSupported

Message

Security Module Discovery failed in slot $slotId$. The running FXOS version does not support the security module; The final supported version is 2.12.

Fault Details

Severity: major
Cause: module-not-supported
Type: server

cfprFaultInst diskFormatFailed

Message

Disk format is failed on slot $slotId$

Fault Details

Severity: major
Cause: disk-format-failed
Type: server

cfprFaultInst CclSubnetNotSupported

Message

Customization Cluster Control Link Subnet is not supported by the application

Fault Details

Severity: major
Cause: ccl-subnet-not-supported
Type: server

cfprFaultInst bladeSwap

Message

Blade swap detected on slot $slotId$

Fault Details

Severity: critical
Cause: blade-swap
Type: server

cfprFaultInst switchConfigFail

Message

Switch configuration failed for Logical Device. Error: $switchErrorMsg$

Fault Details

Severity: critical
Cause: switch-config-failed
Type: server

cfprFaultInst failedConversion

Message

Unrecoverable error during conversion of App Instance $appName$-$startupVersion$ on slot $[ancestor:sm:Slot:slotId]$ during FXOS upgrade

Fault Details

Severity: critical
Cause: conversion-failed
Type: server

cfprFaultInst appNotResponding

Message

App Instance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$ is not responding

Fault Details

Severity: major
Cause: appinstance-not-responding
Type: server

cfprFaultInst appInstallFailed

Message

Failed to install App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-install-failed
Type: server

cfprFaultInst appStartFailed

Message

Failed to start App Instance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-start-failed
Type: server

cfprFaultInst appUpdateFailed

Message

Failed to update App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-update-failed
Type: server

cfprFaultInst appStopFailed

Message

Failed to stop App Instance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-stop-failed
Type: server

cfprFaultInst appFaultState

Message

AppInstance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$ is in failed state. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-fault-state
Type: server

cfprFaultInst appNotInstalled

Message

App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$ is not installed. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-not-installed
Type: server

cfprFaultInst AppInstanceError

Message

Error in App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$. $errorMsg$

Fault Details

Severity: minor
Cause: appinstance-error
Type: server

cfprFaultInst conflictConfig

Message

The external-port-link $name$ conflict with the application. $errorDescription$. To correct it, synchronize and remove the conflict sub-interface, save and deploy from Firepower Management Center. Remove and recreate external-port-link $name$ from MIO, then, synchronize it again from Firepower Management Center.

Fault Details

Severity: major
Cause: external-port-link-conflict-configuration
Type: server

cfprFaultInst incompleteConfig

Message

Logical Device $name$ is not configured correctly. $errorMsg$

Fault Details

Severity: major
Cause: logical-device-incomplete-configuration
Type: server

cfprFaultInst LogicalDeviceError

Message

Error in Logical Device $name$. $errorMsg$

Fault Details

Severity: minor
Cause: logical-device-error
Type: server

cfprFaultInst appInstanceUnsupported

Message

App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$ is not supported in the current bundle. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-unsupported
Type: server

cfprFaultInst appImageCorrupted

Message

The application image $appId$ is corrupted

Fault Details

Severity: major
Cause: app-img-corrupted
Type: server

cfprFaultInst softwareIncompatible

Message

$versionIncompatibleErrorMgr$

Fault Details

Severity: major
Cause: software-version-incompatible
Type: server

cfprFaultInst hwCryptoNotOperable

Message

Hardware crypto is enabled but not operable on $[ancestor:sm:AppInstance2:appName]$-$[ancestor:sm:AppInstance2:identifier]$. Reason: HwCryptoVersion is '$hwCryptoVersion$'.

Fault Details

Severity: major
Cause: hardware-crypto-version-unsupported-or-failure
Type: server

cfprFaultInst hotfixInstallFailed

Message

Failed to install Hotfix $version$ on $[ancestor:sm:AppInstance2:appName]$-$[ancestor:sm:AppInstance2:identifier]$ in slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: hotfix-install-failed
Type: server

cfprFaultInst HotfixErro

Message

Error in Hotfix $version$ on appInstance $[ancestor:sm:AppInstance2:appName]$-$[ancestor:sm:AppInstance2:identifier]$ in slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: minor
Cause: hotfix-error
Type: server

cfprFaultInst Error0

Message

$operStr$ failed on slot $[ancestor:sm:Slot:slotId]$:$errorMsg$

Fault Details

Severity: major
Cause: generic-error
Type: server

cfprFaultInst Error1

Message

Sync Data External Port Link is enabled on $[ancestor:sm:AppInstance2:identifier]$ with error: $errorMsg$ on slot $[ancestor:sm:Slot:slotId]$. Please 'set link-state-sync disabled' on the Logical Device.

Fault Details

Severity: major
Cause: generic-error
Type: server

cfprFaultInst CloudRegistrationFailed

Message

Failed to register the device with the cloud. Error: $errorMessage$

Fault Details

Severity: major
Cause: Cloud-registration-failed
Type: server

cfprFaultInst CloudUnregistrationFailed

Message

Failed to unregister the device with the cloud. Error: $errorMessage$

Fault Details

Severity: major
Cause: Cloud-unregistration-failed
Type: server

cfprFaultInst unsignedCSPLicenseInstalled

Message

Unsigned CSP License Installed $[ancestor:sm:UnsignedCspLicense:licenseFileName]$

Fault Details

Severity: major
Cause: license-installed
Type: server

cfprFaultInst config-failed

Message

Eth vNIC $name$, service profile $[ancestor:ls:Server:name]$ failed to apply configuration

Fault Details

Severity: minor
Cause: configuration-failed
Type: configuration

cfprFaultInst pinningMismatch

Message

Hard pinning target for eth vNIC $name$, service profile $[ancestor:ls:Server:name]$ does not have all the required vlans configured

Fault Details

Severity: warning
Cause: pinning-mismatch
Type: configuration

cfprFaultInst pinningMisconfig

Message

Hard pinning target for eth vNIC $name$, service profile $[ancestor:ls:Server:name]$ is missing or misconfigured

Fault Details

Severity: major
Cause: pinning-misconfig
Type: configuration

cfprFaultInst vlanAccessFault

Message

The named vlan $name$ for vNIC $[ancestor:vnic:Ether:name]$ cannot be accessed from org $[ancestor:org:Org:name]$

Fault Details

Severity: major
Cause: inaccessible-vlan-referenced
Type: configuration

cfprFaultInst vlanUnresolvable

Message

The named vlan $name$ for vNIC $[ancestor:vnic:Ether:name]$ cannot be resolved$

Fault Details

Severity: warning
Cause: referenced-vlan-unresolvable
Type: configuration

cfprFaultInst remoteVlanUnresolvable

Message

The named vlan $name$ for vNIC $[ancestor:vnic:Ether:name]$ cannot be resolved remotely$

Fault Details

Severity: warning
Cause: referenced-remote-vlan-unresolvable
Type: configuration

cfprFaultInst InvalidVlan

Message

Invalid Vlan in the allowed vlan list

Fault Details

Severity: major
Cause: invalid-vlan-in-the-allowed-vlan-list
Type: configuration

cfprFaultInst vlanConflictPermit

Message

There are multiple vlans with id $id$ have different accessability configured.

Fault Details

Severity: warning
Cause: vlan-conflict-permit
Type: configuration

cfprFaultInst profileConfigIncorrect

Message

The Port Profile $name$ has an invalid configuration.

Fault Details

Severity: warning
Cause: profile-config-incorrect
Type: configuration

cfprFaultInst config-failed

Message

iSCSI vNIC $name$, service profile $[ancestor:ls:Server:name]$ has duplicate iqn name $initiatorName$

Fault Details

Severity: major
Cause: configuration-failed
Type: configuration

cfprFaultInst virtualization-conflict

Message

Multiple connection policies cannot be assigned to the same Eth vNIC

Fault Details

Severity: major
Cause: multiple-connection-policies
Type: configuration

cfprFaultInst virtualization-netflow-conflict

Message

Netflow and VMQ/SRIOV-USNIC policies cannot be assigned to the same Eth vNIC

Fault Details

Severity: major
Cause: multiple-connection-policies
Type: configuration

cfprFaultInst iscsi-config-failed

Message

Service Profile $[ancestor:ls:Server:name]$ configuration failed due to iSCSI issue $iscsiConfigIssues$

Fault Details

Severity: major
Cause: configuration-failed
Type: configuration

cfprFaultInst empty

Message

UUID suffix pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst failed

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) virtual network interface allocation failed.

Server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) virtual network interface allocation failed.

Fault Details

Severity: major
Cause: insufficient-resources
Type: server

cfprFaultInst insufficientlyEquipped

Message

Server $id$ (service profile: $assignedToDn$) has insufficient number of DIMMs, CPUs and/or adapters

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has insufficient number of DIMMs, CPUs and/or adaptersd.

Fault Details

Severity: minor
Cause: insufficiently-equipped
Type: equipment

cfprFaultInst identityUnestablishable

Message

Server $id$ (service profile: $assignedToDn$) has an invalid FRU

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has an invalid FRU

Fault Details

Severity: minor
Cause: identity-unestablishable
Type: equipment

cfprFaultInst powerError

Message

Motherboard of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) power: $operPower$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) power: $operPower$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst powerFail

Message

Motherboard of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) power: $power$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) power: $power$

Fault Details

Severity: critical
Cause: power-problem
Type: environmental

cfprFaultInst thermalProblem

Message

Motherboard $faultQualifier$ of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) thermal: $thermal$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) thermal: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst powerUsageProblem

Message

Motherboard $faultQualifier$ of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) powerUsage: $powerUsage$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) powerUsage: $powerUsage$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst powerProblem

Message

Server $id$ (service profile: $assignedToDn$) oper state: $operState$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) oper state: $operState$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst thermalProblem

Message

Server $id$ (service profile: $assignedToDn$) oper state: $operState$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) oper state: $operState$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental
 

cfprFaultInst biosPostTimeout

Message

Server $id$ (service profile: $assignedToDn$) BIOS failed power-on self test

Blade $chassisId$/$slotId$ (service profile: $assignedToDn$) BIOS failed power-on self test

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst discoveryFailed

Message

Server $id$ (service profile: $assignedToDn$) discovery: $discovery$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) discovery: $discovery$

Fault Details

Severity: major
Cause: discovery-failed
Type: operational

cfprFaultInst associationFailed

Message

Service profile $assignedToDn$ failed to associate with server $id$

Service profile $assignedToDn$ failed to associate with server $chassisId$/$slotId$

Fault Details

Severity: critical
Cause: association-failed
Type: configuration

cfprFaultInst disassociationFailed

Message

Failed to disassociate server $id$

Failed to disassociate server $chassisId$/$slotId$

Fault Details

Severity: major
Cause: disassociation-failed
Type: configuration

cfprFaultInst inoperable

Message

Server $id$ (service profile: $assignedToDn$) health: $operability$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) health: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst UnassignedMissing

Message

Server $id$ (no profile) missing

Server $chassisId$/$slotId$ (no profile) missing

Fault Details

Severity: minor
Cause: equipment-missing
Type: equipment

cfprFaultInst AssignedMissing

Message

Server $id$ (service profile: $assignedToDn$) missing

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) missing

Fault Details

Severity: major
Cause: equipment-missing
Type: equipment

cfprFaultInst Unidentified

Message

Server $id$ (service profile: $assignedToDn$) has an invalid FRU: $presence$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has an invalid FRU: $presence$

Fault Details

Severity: minor
Cause: identity-unestablishable
Type: equipment

cfprFaultInst UnassignedInaccessible

Message

Server $id$ (no profile) inaccessible

Server $chassisId$/$slotId$ (no profile) inaccessible

Fault Details

Severity: warning
Cause: equipment-inaccessible
Type: equipment

cfprFaultInst AssignedInaccessible

Message

Server $id$ (service profile: $assignedToDn$) inaccessible

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) inaccessible

Fault Details

Severity: minor
Cause: equipment-inaccessible
Type: equipment

cfprFaultInst NetworkMisconfigured

Message

Server $id$ (service profile: $assignedToDn$) inaccessible

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) inaccessible

Fault Details

Severity: minor
Cause: equipment-inaccessible
Type: equipment

cfprFaultInst AdapterMismatch

Message

Server $id$ (service profile: $assignedToDn$) has invalid adapter combinaton

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has invalid adapter combination

Fault Details

Severity: critical
Cause: adaptor-mismatch
Type: equipment

cfprFaultInst cmosVoltageThresholdCritical

Message

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $cmosVoltage$

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:RackUnit:id]$ is $cmosVoltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst cmosVoltageThresholdNonRecoverable

Message

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $cmosVoltage$

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:RackUnit:id]$ is $cmosVoltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageThresholdUpperNonRecoverable

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageThresholdLowerNonRecoverable

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageUpperThresholdCritical

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageLowerThresholdCritical

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst empty

Message

server pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst post-failure

Message

Server $id$ POST or diagnostic failure

Server $chassisId$/$slotId$ POST or diagnostic failure

Fault Details

Severity: major
Cause: equipment-problem
Type: server

cfprFaultInst inoperable

Message

RTC Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst thermalNonCritical

Message

IO Hub on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

IO Hub on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

IO Hub on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst powerCycleRequired

Message

Board controller upgraded, manual a/c power cycle required on server $[ancestor:compute:Physical:serverId]$

Fault Details

Severity: critical
Cause: boardCtrlUpgraded
Type: generic

cfprFaultInst vmediaMountFailed

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) vmedia mapping $mappingName$ has failed.

Server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) vmedia mapping $mappingName$ has failed.$

Fault Details

Severity: major
Cause: vmediaMountInaccessible
Type: server
 

The following are MIB faults of Firepower 2100 and Secure Firewall 3100 devices:

cfprFaultInst degraded

Message

Fabric Interconnect $id$, HA Cluster interconnect link failure

Fault Details

Severity: major
Cause: link-down
Type: network

cfprFaultInst down

Message

Fabric Interconnect $id$, HA Cluster interconnect total link failure

Fault Details

Severity: critical
Cause: link-down
Type: network

cfprFaultInst election-failure

Message

Fabric Interconnect $id$, election of primary managemt instance has failed

Fault Details

Severity: critical
Cause: election-failure
Type: management

cfprFaultInst management-services-failure

Message

Fabric Interconnect $id$, management services have failed

Fault Details

Severity: critical
Cause: management-services-failure
Type: management

cfprFaultInst management-services-unresponsive

Message

Fabric Interconnect $id$, management services are unresponsive

Fault Details

Severity: critical
Cause: management-services-unresponsive
Type: management

cfprFaultInst ha-not-ready

Message

Fabric Interconnect $id$, HA functionality not ready

Fault Details

Severity: major
Cause: ha-not-ready
Type: management

cfprFaultInst version-incompatible

Message

Fabric Interconnect $id$, management services, incompatible versions

Fault Details

Severity: critical
Cause: version-incompatible
Type: management

cfprFaultInst device-1-shared-storage-error

Message

device $chassis1$, error accessing shared-storage

Fault Details

Severity: warning
Cause: device-shared-storage-error
Type: management

cfprFaultInst device-2-shared-storage error

Message

device $chassis2$, error accessing shared-storage

Fault Details

Severity: warning
Cause: device-shared-storage-error
Type: management

cfprFaultInst device-3-shared-storage-error

Message

device $chassis3$, error accessing shared-storage

Fault Details

Severity: warning
Cause: device-shared-storage-error
Type: management

cfprFaultInst ha-ssh-keys-mismatched

Message

Fabric Interconnect $id$, management services, mismatched SSH keys

Fault Details

Severity: major
Cause: ha-ssh-keys-mismatched
Type: management

cfprFaultInst FPRM process failure

Message

FPRM process $name$ failed on FI $switchId$

Fault Details

Severity: critical
Cause: FPRM process failure
Type: management

cfprFaultInst mEpLogLog

Message

Log capacity on $[ancestor:equipment:IOCard:side]$ IOM $[ancestor:equipment:IOCard:chassisId]$/$[ancestor:equipment:IOCard:id]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:RackUnit:id]$ is $capacity$

Fault Details

Severity: info
Cause: log-capacity
Type: operational

cfprFaultInst mEpLogVeryLow

Message

Log capacity on $[ancestor:equipment:IOCard:side]$ IOM $[ancestor:equipment:IOCard:chassisId]$/$[ancestor:equipment:IOCard:id]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:RackUnit:id]$ is $capacity$

Fault Details

Severity: info
Cause: log-capacity
Type: operational

cfprFaultInst mEpLogFull

Message

Log capacity on $[ancestor:equipment:IOCard:side]$ IOM $[ancestor:equipment:IOCard:chassisId]$/$[ancestor:equipment:IOCard:id]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $capacity$

Log capacity on Management Controller on server $[ancestor:compute:RackUnit:id]$ is $capacity$

Fault Details

Severity: info
Cause: log-capacity
Type: operational

cfprFaultInst transferError

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ $type$ transfer failed: $operState$

Server $[ancestor:compute:RackUnit:id]$ $type$ transfer failed: $operState$

Fault Details

Severity: info
Cause: file-transfer-failed
Type: operational

cfprFaultInst MisConnect

Message

Management Port $id$ in server $[ancestor:compute:RackUnit:id]$ is mis connected

Fault Details

Severity: warning
Cause: link-misconnected
Type: operational

cfprFaultInst Missing

Message

Connection to Management Port $id$ in server $[ancestor:compute:RackUnit:id]$ is missing

Fault Details

Severity: warning
Cause: link-missinglink-missing
Type: operational

cfprFaultInst New

Message

New connection discovered on Management Port $id$ in server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: warning
Cause: new-link
Type: operational

cfprFaultInst disabled

Message

Management Connection $type$ in server $[ancestor:compute:RackUnit:id]$ is not operational

Fault Details

Severity: warning
Cause: another-connection-already-enabled
Type: operational

cfprFaultInst unused

Message

Management Connection $type$ in server $[ancestor:compute:RackUnit:id]$ is unused

Fault Details

Severity: info
Cause: connection-unused
Type: operational

cfprFaultInst unsupportedConnectivity

Message

Unsupported connectivity for management connection $type$ in server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: minor
Cause: unsupported-connectivity
Type: operational

cfprFaultInst unsupportedDimmBlacklisting

Message

Dimm blacklisting is not supported on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Dimm blacklisting is not supported on server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: info
Cause: incompatible-server-firmware
Type: environmental

cfprFaultInst namedInbandVlanUnresolved

Message

$configMessage$

Fault Details

Severity: minor
Cause: named-inband-vlan-unresolved
Type: management

cfprFaultInst inbandUnsupportedServer

Message

$configMessage$

Fault Details

Severity: minor
Cause: inband-unsupported-server
Type: management

cfprFaultInst inbandUnsupportedFirmware

Message

$configMessage$

Fault Details

Severity: minor
Cause: unsupported-cimc-firmware
Type: management

cfprFaultInst loadErrors

Message

Load errors: File parse errors: $fileParseFailures$, provider load failures: $providerLoadFailures$, XML element load errors: $loadErrors$.

Fault Details

Severity: major
Cause: load-catalog-failed
Type: management

cfprFaultInst failed

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) virtual network interface allocation failed.

Server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) virtual network interface allocation failed.

Fault Details

Severity: major
Cause: insufficient-resources
Type: server

cfprFaultInst insufficientlyEquipped

Message

Server $id$ (service profile: $assignedToDn$) has insufficient number of DIMMs, CPUs and/or adapters

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has insufficient number of DIMMs, CPUs and/or adaptersd.

Fault Details

Severity: minor
Cause: insufficiently-equipped
Type: equipment

cfprFaultInst identityUnestablishable

Message

Server $id$ (service profile: $assignedToDn$) has an invalid FRU

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has an invalid FRU

Fault Details

Severity: minor
Cause: identity-unestablishable
Type: equipment

cfprFaultInst powerError

Message

Motherboard of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) power: $operPower$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) power: $operPower$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst powerFail

Message

Motherboard of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) power: $power$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) power: $power$

Fault Details

Severity: critical
Cause: power-problem
Type: environmental

cfprFaultInst thermalProblem

Message

Motherboard $faultQualifier$ of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) thermal: $thermal$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) thermal: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst powerUsageProblem

Message

Motherboard $faultQualifier$ of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) powerUsage: $powerUsage$

Motherboard of server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) powerUsage: $powerUsage$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst powerProblem

Message

Server $id$ (service profile: $assignedToDn$) oper state: $operState$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) oper state: $operState$

Fault Details

Severity: major
Cause: power-problem
Type: environmental
 

cfprFaultInst biosPostTimeout

Message

Server $id$ (service profile: $assignedToDn$) BIOS failed power-on self test

Blade $chassisId$/$slotId$ (service profile: $assignedToDn$) BIOS failed power-on self test

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst discoveryFailed

Message

Server $id$ (service profile: $assignedToDn$) discovery: $discovery$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) discovery: $discovery$

Fault Details

Severity: major
Cause: discovery-failed
Type: operational

cfprFaultInst associationFailed

Message

Service profile $assignedToDn$ failed to associate with server $id$

Service profile $assignedToDn$ failed to associate with server $chassisId$/$slotId$

Fault Details

Severity: critical
Cause: association-failed
Type: configuration

cfprFaultInst disassociationFailed

Message

Failed to disassociate server $id$

Failed to disassociate server $chassisId$/$slotId$

Fault Details

Severity: major
Cause: disassociation-failed
Type: configuration

cfprFaultInst inoperable

Message

Server $id$ (service profile: $assignedToDn$) health: $operability$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) health: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst UnassignedMissing

Message

Server $id$ (no profile) missing

Server $chassisId$/$slotId$ (no profile) missing

Fault Details

Severity: minor
Cause: equipment-missing
Type: equipment

cfprFaultInst AssignedMissing

Message

Server $id$ (service profile: $assignedToDn$) missing

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) missing

Fault Details

Severity: major
Cause: equipment-missing
Type: equipment

cfprFaultInst Unidentified

Message

Server $id$ (service profile: $assignedToDn$) has an invalid FRU: $presence$

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has an invalid FRU: $presence$

Fault Details

Severity: minor
Cause: identity-unestablishable
Type: equipment

cfprFaultInst NetworkMisconfigured

Message

Server $id$ (service profile: $assignedToDn$) has mis-configured network vif resources

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has mis-configured network vif resources

Fault Details

Severity: minor
Cause: vif-ids-mismatch
Type: equipment

cfprFaultInst AdapterMismatch

Message

Server $id$ (service profile: $assignedToDn$) has invalid adapter combinaton

Server $chassisId$/$slotId$ (service profile: $assignedToDn$) has invalid adapter combination

Fault Details

Severity: critical
Cause: adaptor-mismatch
Type: equipment

cfprFaultInst cmosVoltageThresholdCritical

Message

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $cmosVoltage$

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:RackUnit:id]$ is $cmosVoltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst cmosVoltageThresholdNonRecoverable

Message

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $cmosVoltage$

Possible loss of CMOS settings: CMOS battery voltage on server $[ancestor:compute:RackUnit:id]$ is $cmosVoltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageThresholdUpperNonRecoverable

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageThresholdLowerNonRecoverable

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageUpperThresholdCritical

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst motherBoardVoltageLowerThresholdCritical

Message

Motherboard input voltage(12V/5V/3V) in server $[ancestor:compute:RackUnit:id]$ is $voltage$

Motherboard $faultQualifier$ input voltage(12V/5V/3V) in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst empty

Message

server pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst post-failure

Message

Server $id$ POST or diagnostic failure

Server $chassisId$/$slotId$ POST or diagnostic failure

Fault Details

Severity: major
Cause: equipment-problem
Type: server

cfprFaultInst inoperable

Message

RTC Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst thermalNonCritical

Message

IO Hub on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

IO Hub on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

IO Hub on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst powerCycleRequired

Message

Board controller upgraded, manual a/c power cycle required on server $[ancestor:compute:Physical:serverId]$

Fault Details

Severity: critical
Cause: boardCtrlUpgraded
Type: generic

cfprFaultInst vmediaMountFailed

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ (service profile: $[ancestor:compute:Blade:assignedToDn]$) vmedia mapping $mappingName$ has failed.

Server $[ancestor:compute:RackUnit:id]$ (service profile: $[ancestor:compute:RackUnit:assignedToDn]$) vmedia mapping $mappingName$ has failed.$

Fault Details

Severity: major
Cause: vmediaMountInaccessible
Type: server

cfprFaultInst NoSnmpPolicyForCallhome

Message

FPR Manager cannot apply Callhome policy if SNMP Policy is not configured or if SNMP Syscontact has an empty value. The Callhome policy from FPR Central has not been applied.

Fault Details

Severity: minor
Cause: callhome-config-error
Type: configuration

cfprFaultInst linkState

Message

Virtual interface $id$ link state is down

Fault Details

Severity: major
Cause: vif-down
Type: management

cfprFaultInst satellite-connection-absent

Message

No link between IOM port $chassisId$/$slotId$/$portId$ and fabric interconnect $switchId$:$peerSlotId$/$peerPortId$

Fault Details

Severity: major
Cause: satellite-connection-absent
Type: connectivity
 

cfprFaultInst satellite-wiring-problem

Message

Invalid connection between IOM port $chassisId$/$slotId$/$portId$ and fabric interconnect $switchId$:$peerSlotId$/$peerPortId$

Fault Details

Severity: info
Cause: satellite-mis-connected
Type: connectivity

cfprFaultInst satellite-wiring-numbers-unexpected

Message

Chassis discovery policy conflict: Link IOM $chassisId$/$slotId$/$portId$ to fabric interconnect $switchId$:$peerSlotId$/$peerPortId$ not configured

Fault Details

Severity: info
Cause: unexpected-number-of-links
Type: connectivity

cfprFaultInst powerSupplyProblem

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ power: $power$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ power: $power$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ power: $power$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ power: $power$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst offline

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ power: $power$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ power: $power$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ power: $power$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ power: $power$

Fault Details

Severity: warning
Cause: equipment-offline
Type: environmental

cfprFaultInst powerSupplyShutdown

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ shutdown reason:$powerStateQualifier$

Fault Details

Severity: major
Cause: equipment-offline
Type: environmental

cfprFaultInst fanModuleUnidentified

Message

Fan module inserted unidentified

Fault Details

Severity: major
Cause: fan-module-unidentified
Type: equipment

cfprFaultInst psuUnidentified

Message

Power supply inserted into slot $id$ unidentified

Fault Details

Severity: major
Cause: psu-unidentified
Type: equipment

cfprFaultInst psuFanProblem

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ Fan Status: $psuFanStatus$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ Fan Status: $psuFanStatus$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ Fan Status: $psuFanStatus$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ Fan Status: $psuFanStatus$

Fault Details

Severity: major
Cause: psu-fan-problem
Type: equipment

cfprFaultInst identity-unestablishable

Message

Chassis $id$ has an invalid FRU

Fault Details

Severity: major
Cause: identity-unestablishable
Type: equipment

cfprFaultInst identity-unestablishable

Message

Fex $id$ has an invalid FRU

Fault Details

Severity: major
Cause: identity-unestablishable
Type: equipment

cfprFaultInst fex-unsupported

Message

Fex $id$ with model $model$ is unsupported

Fault Details

Severity: major
Cause: fex-unsupported
Type: equipment

cfprFaultInst degraded

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst degraded

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fan $id$ in fex $[ancestor:equipment:Fex:id]$ operability: $operability$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

Chassis $id$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst boot-problem

Message

Chassis $id$ operability: $operability$

Fault Details

Severity: major
Cause: boot-problem
Type: equipment
 

cfprFaultInst inoperable

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst inoperable

Message

Fan $id$ under chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Fan $id$ in fex $[ancestor:equipment:Fex:id]$ operability: $operability$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst inoperable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ operability: $operability$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ operability: $operability$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ operability: $operability$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst removed

Message

$side$ IOM $chassisId$/$id$ ($switchId$) is removed

Fault Details

Severity: critical
Cause: equipment-removed
Type: equipment

cfprFaultInst inaccessible

Message

$side$ IOM $chassisId$/$id$ ($switchId$) is inaccessible

Fault Details

Severity: critical
Cause: equipment-inaccessible
Type: equipment

cfprFaultInst post-failure

Message

$side$ IOM $chassisId$/$id$ ($switchId$) POST failure

Fault Details

Severity: major
Cause: equipment-problem
Type: equipment

cfprFaultInst post-failure

Message

fex $id$ POST failure

Fault Details

Severity: major
Cause: equipment-problem
Type: equipment

cfprFaultInst missing

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ presence: $presence$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ presence: $presence$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ presence: $presence$

Fault Details

Severity: critical
Cause: equipment-missing
Type: equipment

cfprFaultInst missing

Message

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ presence: $presence$

Fan $id$ in fex $[ancestor:equipment:Fex:id]$ presence: $presence$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ presence: $presence$

Fault Details

Severity: critical
Cause: equipment-missing
Type: equipment

cfprFaultInst missing

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ presence: $presence$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ presence: $presence$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ presence: $presence$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ presence: $presence$

Fault Details

Severity: critical
Cause: equipment-missing
Type: equipment

cfprFaultInst thermalProblem

Message

$side$ IOM $chassisId$/$id$ ($switchId$) operState: $operState$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

$side$ IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Chassis thermal state is $thermal$. $faultMsg$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

$side$ IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Fan module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Fan module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fan module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ temperature: $thermal$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ temperature: $thermal$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst voltageThresholdNonCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ voltage: $voltage$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ voltage: $voltage$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ voltage: $voltage$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ voltage: $voltage$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ voltage: $voltage$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ voltage: $voltage$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdNonRecoverable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ voltage: $voltage$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ voltage: $voltage$

Power supply $id$ in fex $[ancestor:equipment:Fex:id]$ voltage: $voltage$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: critical
Cause: voltage-problem
Type: environmental

cfprFaultInst perfThresholdNonCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ output power: $perf$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ output power: $perf$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ output power: $perf$

Fault Details

Severity: minor
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdCritical

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ output power: $perf$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ output power: $perf$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ output power: $perf$

Fault Details

Severity: major
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdNonRecoverable

Message

Power supply $id$ in chassis $[ancestor:equipment:Chassis:id]$ output power: $perf$

Power supply $id$ in fabric interconnect $[ancestor:network:Element:id]$ output power: $perf$

Power supply $id$ in server $[ancestor:compute:RackUnit:id]$ output power: $perf$

Fault Details

Severity: critical
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdNonCritical

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: info
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdCritical

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: info
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdNonRecoverable

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: info
Cause: performance-problem
Type: equipment

cfprFaultInst perfThresholdLowerNonRecoverable

Message

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under chassis $[ancestor:equipment:Chassis:id]$ speed: $perf$

Fan $id$ in fabric interconnect $[ancestor:network:Element:id]$ speed: $perf$

Fan $id$ in Fan Module $[ancestor:equipment:FanModule:tray]$-$[ancestor:equipment:FanModule:id]$ under server $[ancestor:compute:RackUnit:id]$ speed: $perf$

Fault Details

Severity: critical
Cause: performance-problem
Type: equipment

cfprFaultInst firmwareUpgrade

Message

Chassis controller in IOM $chassisId$/$id$ ($switchId$) firmware upgrade problem: $upgradeStatus$

Fault Details

Severity: major
Cause: firmware-upgrade-problem
Type: equipment

cfprFaultInst unsupportedConnectivity

Message

Current connectivity for chassis $id$ does not match discovery policy: $configState$

Fault Details

Severity: major
Cause: unsupported-connectivity-configuration
Type: connectivity

cfprFaultInst unacknowledged

Message

Chassis $id$ connectivity configuration: $configState$

Fault Details

Severity: warning
Cause: equipment-unacknowledged
Type: connectivity

cfprFaultInst unsupportedConnectivity

Message

IOM $chassisId$/$id$ ($switchId$) current connectivity does not match discovery policy or connectivity is unsupported: $configState$

Fault Details

Severity: major
Cause: unsupported-connectivity-configuration
Type: connectivity

cfprFaultInst autoUpgradingFirmware

Message

IOM $chassisId$/$id$ ($switchId$) is auto upgrading firmware

Fault Details

Severity: major
Cause: auto-firmware-upgrade
Type: connectivity

cfprFaultInst unacknowledged

Message

IOM $chassisId$/$id$ ($switchId$) connectivity configuration: $configState$

Fault Details

Severity: warning
Cause: equipment-unacknowledged
Type: connectivity

cfprFaultInst peerDisconnected

Message

IOM $chassisId$/$id$ ($switchId$) peer connectivity: $peerCommStatus$

Fault Details

Severity: warning
Cause: equipment-disconnected
Type: connectivity

cfprFaultInst identity

Message

Chassis $id$ has a mismatch between FRU identity reported by Fabric/IOM vs. FRU identity reported by CMC

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst invalid-fru

Message

Chassis $id$ has a empty value for FRU identity reported by CMC.

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst powerProblem

Message

Power state on chassis $id$ is $power$

Fault Details

Severity: major
Cause: power-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Chassis thermal state is $thermal$. $faultMsg$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Thermal condition on chassis $id$. $thermalStateQualifier$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Thermal condition on chassis $id$. $thermalStateQualifier$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst identity

Message

$side$ IOM $chassisId$/$id$ ($switchId$) has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst identity

Message

Fex $id$ has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst identity

Message

Fan Module $tray$-$id$ in chassis $[ancestor:equipment:Chassis:id]$ has a malformed FRU

Fan Module $tray$-$id$ in server $[ancestor:compute:RackUnit:id]$ has a malformed FRU

Fan Module $tray$-$id$ in fabric interconnect $[ancestor:network:Element:id]$ has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst identity

Message

Power supply $id$ on chassis $[ancestor:equipment:Chassis:id]$ has a malformed FRU

Power supply $id$ on server $[ancestor:compute:RackUnit:id]$ has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst PowerThreshold

Message

Power supply $id$ on chassis $[ancestor:equipment:Chassis:id]$ has exceeded its power threshold

Power supply $id$ on server $[ancestor:compute:RackUnit:id]$ has exceeded its power threshold

Fault Details

Severity: critical
Cause: power-problem
Type: equipment

cfprFaultInst InputError

Message

Power supply $id$ on chassis $[ancestor:equipment:Chassis:id]$ has disconnected cable or bad input voltage

Power supply $id$ on server $[ancestor:compute:RackUnit:id]$ has disconnected cable or bad input voltage

Fault Details

Severity: critical
Cause: power-problem
Type: equipment

cfprFaultInst PowerOff

Message

Switch card is powered down.

Fault Details

Severity: critical
Cause: power-down
Type: equipment

cfprFaultInst Mismatch

Message

EPM card in slot $id$ mismatch the previous EPM card, need reboot the box

Fault Details

Severity: critical
Cause: unsupported
Type: equipment

cfprFaultInst Unsupported

Message

Switch/EPM card in slot $id$ is not supported or recognized

Fault Details

Severity: critical
Cause: unsupported
Type: equipment
 

cfprFaultInst Act2LiteFail

Message

Failed Identification Test in slot - $id$ ($descr$). The module in this slot may not be a genuine product. warranties and support programs only apply to genuine products. If its determined that your insertion of non genuine modules into a product is the cause of a support issue, support under your warranty may be denied or under a support program such as SmartNet.

Fault Details

Severity: critical
Cause: act2-fail
Type: equipment

cfprFaultInst CriticalError

Message

Health LED of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ shows error. Reason: $healthLedStateQualifier

Health LED of server $[ancestor:compute:RackUnit:id]$ shows error. Reason: $healthLedStateQualifier$

Fault Details

Severity: critical
Cause: health-led-amber-blinking
Type: equipment

cfprFaultInst SlaveTpm

Message

Server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$, has a Tpm present on the Slave Board.

Fault Details

Severity: info
Cause: tpm-on-slave-board
Type: equipment

cfprFaultInst MinorError

Message

Health LED of server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ shows error. Reason: $healthLedStateQualifier

Health LED of server $[ancestor:compute:RackUnit:id]$ shows error. Reason: $healthLedStateQualifier$

Fault Details

Severity: minor
Cause: health-led-amber
Type: equipment

cfprFaultInst removed

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) is removed

Fault Details

Severity: critical
Cause: equipment-removed
Type: equipment

cfprFaultInst thermalProblem

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) operState: $operState$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst identity

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) has a malformed FRU

Fault Details

Severity: critical
Cause: fru-problem
Type: equipment

cfprFaultInst cpuThermalThresholdCritical

Message

$side$ FI IOM $chassisId$/$id$ ($switchId$) processor temperature exceeded the limit

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst mgmtifdown

Message

Management interface on Fabric Interconnect $id$ is $operState$

Fault Details

Severity: major
Cause: mgmtif-down
Type: management

cfprFaultInst ArpTargetsNotValid

Message

Invalid ARP Targets configured for Management Interface Polling. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: arp-targets-config-error
Type: management

cfprFaultInst NdiscTargetsNotValid

Message

Invalid NDISC Targets configured for Management Interface Polling. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: ndisc-targets-config-error
Type: management

cfprFaultInst gracePeriodWarning

Message

FPR domain $name$ registered with FPR Central has entered into the grace period.

Fault Details

Severity: warning
Cause: license-graceperiod-entered
Type: management

cfprFaultInst gracePeriodWarning2

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 10 days

Fault Details

Severity: warning
Cause: license-graceperiod-10days
Type: management

cfprFaultInst gracePeriodWarning3

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 30 days

Fault Details

Severity: warning
Cause: license-graceperiod-30days
Type: management

cfprFaultInst gracePeriodWarning4

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 60 days

Fault Details

Severity: warning
Cause: license-graceperiod-60days
Type: management

cfprFaultInst gracePeriodWarning5

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 90 days

Fault Details

Severity: major
Cause: license-graceperiod-90days
Type: management

cfprFaultInst gracePeriodWarning6

Message

FPR Domain $name$ registered with FPR Central is running in the grace period for more than 119 days

Fault Details

Severity: critical
Cause: license-graceperiod-119days
Type: management

cfprFaultInst gracePeriodWarning7

Message

Grace period for FPR Domain $name$ registered with FPR Central has expired. Please acquire a license for the same.

Fault Details

Severity: critical
Cause: license-graceperiod-expired
Type: management

cfprFaultInst gracePeriodWarning1

Message

FPR Domain $name$ is registered with FPR Central without a valid license.

Fault Details

Severity: critical
Cause: license-insufficient
Type: management

cfprFaultInst misplacedInChassisSlot

Message

Server, vendor($vendor$), model($model$), serial($serial$) in slot $chassisId$/$slotId$ presence: $presence$.

Fault Details

Severity: warning
Cause: server-moved
Type: equipment

cfprFaultInst serverIdentificationProblem

Message

Problem identifying server in slot $chassisId$/$slotId$

Fault Details

Severity: warning
Cause: server-identification-problem
Type: equipment
 

cfprFaultInst PrimaryVlanMissingForIsolated

Message

Primary Vlan can not be resolved for isolated vlan $name$

Fault Details

Severity: minor
Cause: primary-vlan-missing-for-isolated
Type: network

cfprFaultInst PrimaryVlanMissingForCommunity

Message

Primary Vlan can not be resolved for community vlan $name$

Fault Details

Severity: minor
Cause: primary-vlan-missing-for-community
Type: network

cfprFaultInst empty

Message

LAN Pin Group $name$ is empty

Fault Details

Severity: minor
Cause: empty-pin-group
Type: server

cfprFaultInst down

Message

$[ancestor:fabric:EthLan:type]$ Member $slotId$/$aggrPortId$/$portId$ of Port-Channel $[ancestor:fabric:EthLanPc:portId]$ on fabric interconnect $[ancestor:fabric:EthLan:id]$ is down, membership: $membership$

$[ancestor:fabric:EthLan:type]$ Member $slotId$/$portId$ of Port-Channel $[ancestor:fabric:EthLanPc:portId]$ on fabric interconnect $[ancestor:fabric:EthLan:id]$ is down, membership: $membership$

Fault Details

Severity: major
Cause: membership-down
Type: network

cfprFaultInst down

Message

$[ancestor:fabric:EthEstc:type]$ Member $slotId$/$aggrPortId$/$portId$ of Port-Channel $[ancestor:fabric:EthEstcPc:portId]$ on fabric interconnect $[ancestor:fabric:EthEstc:id]$ is down, membership: $membership$

$[ancestor:fabric:EthEstc:type]$ Member $slotId$/$portId$ of Port-Channel $[ancestor:fabric:EthEstcPc:portId]$ on fabric interconnect $[ancestor:fabric:EthEstc:id]$ is down, membership: $membership$

Fault Details

Severity: major
Cause: membership-down
Type: network

cfprFaultInst down

Message

Pin target is a non-existent interface

Fault Details

Severity: warning
Cause: invalid-target
Type: network

cfprFaultInst down

Message

$[ancestor:fabric:DceSwSrv:type]$ Member $slotId$/$aggrPortId$/$portId$ of Port-Channel $[ancestor:fabric:DceSwSrvPc:portId]$ on fabric interconnect $[ancestor:fabric:DceSwSrv:id]$ is down, membership: $membership$

$[ancestor:fabric:DceSwSrv:type]$ Member $slotId$/$portId$ of Port-Channel $[ancestor:fabric:DceSwSrvPc:portId]$ on fabric interconnect $[ancestor:fabric:DceSwSrv:id]$ is down, membership: $membership$

Fault Details

Severity: major
Cause: membership-down
Type: network

cfprFaultInst spanConfigFail

Message

Configuration for traffic monitor $name$ failed, reason: $configFailReason$

Fault Details

Severity: major
Cause: config-error
Type: network

cfprFaultInst epTransModeFail

Message

Port constraint violation on switch $id$: $confQual$

Fault Details

Severity: critical
Cause: config-error
Type: network

cfprFaultInst mismatch-a

Message

VLAN $name$ has $overlapStateForA$ with another vlan under lan-cloud/appliance-cloud for the fabric interconnect A

Fault Details

Severity: major
Cause: vlan-mismatch
Type: network

cfprFaultInst mismatch-b

Message

VLAN $name$ has $overlapStateForB$ with another vlan under lan-cloud/appliance-cloud for the fabric interconnect B

Fault Details

Severity: major
Cause: vlan-mismatch
Type: network

cfprFaultInst errorAssocPrimary

Message

VLAN $name$ is in error state because the associated primary vlan $assocPrimaryVlanState$

Fault Details

Severity: major
Cause: vlan-error-assoc-primary
Type: network

cfprFaultInst errorMisconfigured

Message

Interface $name$ is $operState$. Reason: $operStateReason$

Fault Details

Severity: critical
Cause: interface-misconfigured
Type: network

cfprFaultInst missingPrimaryVlan

Message

Primary vlan missing from fabric: $switchId$, port: $slotId$/$aggrPortId$/$portId$.

Primary vlan missing from fabric: $switchId$, port: $slotId$/$portId$.

Fault Details

Severity: major
Cause: missing-primary-vlan
Type: management

cfprFaultInst udldLinkDown

Message

UDLD state for ether port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $switchId$ is: $udldOperState$.

UDLD state for ether port $slotId$/$portId$ on fabric interconnect $switchId$ is: $udldOperState$.

Fault Details

Severity: warning
Cause: udld-link-down
Type: network
 

cfprFaultInst missingPrimaryVlan

Message

Primary vlan missing from fabric: $switchId$, port-channel: $portId$.

Fault Details

Severity: major
Cause: missing-primary-vlan
Type: management

cfprFaultInst overlapping-vlan

Message

On Fabric: $switchId$, Port: $slotId$/$aggrPortId$/$portId$ following overlapping VLANs detected: $overlappingVlans$

On Fabric: $switchId$, Port: $slotId$/$portId$ following overlapping VLANs detected: $overlappingVlans$

Fault Details

Severity: info
Cause: configuration-error
Type: network

cfprFaultInst overlapping-vlan

Message

Overlapping VLANs detected on Fabric: $switchId$, Port: $portId$ in configured VLANs: $overlappingVlans$

Fault Details

Severity: info
Cause: configuration-error
Type: network

cfprFaultInst misconfigured-mcast-policy

Message

VLAN $name$ multicast policy $mcastPolicyName$ is non-default.

Fault Details

Severity: major
Cause: vlan-mcast-policy-misconfigured
Type: network

cfprFaultInst NamedVlanUnresolved

Message

VLAN $name$ for VLAN group $[ancestor:fabric:NetGroup:name]$ cannot be resolved to any existing vlans.

Fault Details

Severity: warning
Cause: named-vlan-unresolved
Type: network

cfprFaultInst down

Message

$[ancestor:fabric:EthLan:type]$ Member $slotId$/$portId$ of Management Port-Channel $[ancestor:fabric:EthLanPc:portId]$ on firepower is down, membership: $membership$

Fault Details

Severity: major
Cause: membership-down
Type: network

cfprFaultInst empty

Message

FC pool $purpose$ $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst imageMissing

Message

$type$ image with vendor $hwVendor$, model $hwModel$ and version $version$ is deleted

Fault Details

Severity: major
Cause: image-deleted
Type: management

cfprFaultInst imageUnusable

Message

backup image is unusable. reason: $operStateQual$

Fault Details

Severity: major
Cause: image-unusable
Type: management

cfprFaultInst cantBoot

Message

unable to boot the startup image. End point booted with backup image

Fault Details

Severity: major
Cause: image-cannot-boot
Type: management

cfprFaultInst activateStatusFailed

Message

Activation failed and Activate Status set to failed.

Fault Details

Severity: major
Cause: activation-failed
Type: management

cfprFaultInst cimcFirmwareMismatch

Message

Aggregate blade CIMC firmware mismatch. Firmware: $cimcVersion$

Fault Details

Severity: critical
Cause: cimc-firmware-mismatch
Type: management

cfprFaultInst pldFirmwareMismatch

Message

Aggregate blade board controller firmware mismatch. Firmware: $pldVersion$

Fault Details

Severity: critical
Cause: pld-firmware-mismatch
Type: management

cfprFaultInst defaultHostPackageMissing

Message

Default host firmware package is missing or deleted.

Fault Details

Severity: major
Cause: defaultHostpackMissing
Type: management

cfprFaultInst bundleVersionMissing

Message

Platform version is empty in platform firmware package

Fault Details

Severity: critical
Cause: defaultPlaformVersionMissing
Type: management

cfprFaultInst infraBundleValidationFailure

Message

Software Pack upgrade failed validation

Fault Details

Severity: major
Cause: defaultInfraBundleValidationFailed
Type: management

cfprFaultInst infraBundleUpgradeFailure

Message

Software Pack upgrade failure: $upgradeStatus$

Fault Details

Severity: critical
Cause: defaultInfraBundleUpgradeFailure
Type: management

cfprFaultInst firmwareUpgradeFailure

Message

Failed to upgrade Firmware Image

Fault Details

Severity: critical
Cause: defaultFirmwareUpgradeFailure
Type: management

cfprFaultInst tooManyKeysInstalled

Message

Too many keys on the system Primary/Backup Release Keys($numPrimaryReleaseKeys$, $numBackupReleaseKeys$)

Fault Details

Severity: info
Cause: tooManyKeysOnSystem
Type: management

cfprFaultInst devkeysInstalled

Message

System is installed with development keys

Fault Details

Severity: info
Cause: devkeysInstalledOnSystem
Type: management

cfprFaultInst devkeysInstalled

Message

System is installed with development keys

Fault Details

Severity: info
Cause: devkeysInstalledOnSystem
Type: management

cfprFaultInst fpgaGoldenTooOld

Message

FPGA Golden Version $fpgaGoldenVersion$ must be upgraded to Version $fpgaGoldenRequiredVersion$ or newer.

Fault Details

Severity: major
Cause: fpgaGoldenFailedUpgrade
Type: management

cfprFaultInst unidentifiable-fru

Message

Adapter $id$ in server $[ancestor:compute:RackUnit:id]$ has unidentified FRU

Adapter $id$ in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has unidentified FRU

Fault Details

Severity: major
Cause: unidentifiable-fru
Type: server

cfprFaultInst unidentifiable-fru

Message

Adapter extension $id$ in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has unidentified FRU

Fault Details

Severity: major
Cause: unidentifiable-fru
Type: server

cfprFaultInst missing

Message

Adapter $id$ in server $[ancestor:compute:RackUnit:id]$ presence: $presence$

Adapter $id$ in server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ presence: $presence$

Fault Details

Severity: warning
Cause: equipment-missing
Type: equipment

cfprFaultInst missing

Message

Adapter extension $id$ in server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ presence: $presence$

Fault Details

Severity: warning
Cause: equipment-missing
Type: equipment

cfprFaultInst AdaptorReachability

Message

Adapter $[ancestor:compute:RackUnit:id]$/$id$ is unreachable

Adapter $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$/$id$ is unreachable

Fault Details

Severity: info
Cause: connectivity-problem
Type: connectivity

cfprFaultInst link-down

Message

Adapter $transport$ host interface $[ancestor:compute:RackUnit:id]$/$[ancestor:adaptor:Unit:id]$/$id$ link state: $linkState$, Associated external interface link state: $vcAdminState$

Adapter $transport$ host interface $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$/$[ancestor:adaptor:Unit:id]$/$id$ link state: $linkState$, Associated external interface link state: $vcAdminState$

Fault Details

Severity: major
Cause: link-down
Type: network

cfprFaultInst link-down

Message

Adapter uplink interface $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$/$[ancestor:adaptor:Unit:id]$/$id$ on security module $[ancestor:compute:Blade:slotId]$ link state: $linkState$. Please check switch blade-facing port status. Resetting security module might be required.

Fault Details

Severity: critical
Cause: link-down
Type: network

cfprFaultInst MisConnect

Message

Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ mis-connected

Fault Details

Severity: warning
Cause: link-misconnected
Type: network

cfprFaultInst Missing

Message

Connection to Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ missing

Fault Details

Severity: warning
Cause: link-missing
Type: network

cfprFaultInst MisConnect

Message

Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ mis-connected

Fault Details

Severity: warning
Cause: link-misconnected
Type: network

cfprFaultInst Missing

Message

Connection to Adapter $[ancestor:adaptor:Unit:id]$ eth interface $id$ in server $[ancestor:compute:RackUnit:id]$ missing

Fault Details

Severity: warning
Cause: link-missing
Type: network

cfprFaultInst empty

Message

IP pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst empty

Message

iqn pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst failed

Message

Service profile $name$ failed

Fault Details

Severity: major
Cause: server-failed
Type: server

cfprFaultInst discoveryFailed

Message

Service profile $name$ discovery failed

Fault Details

Severity: major
Cause: discovery-failed
Type: server

cfprFaultInst configFailure

Message

Service profile $name$ configuration failed due to $configQualifier$

Fault Details

Severity: major
Cause: configuration-failure
Type: server

cfprFaultInst maintenanceFailed

Message

Service profile $name$ maintenance failed

Fault Details

Severity: major
Cause: maintanence-failed
Type: server

cfprFaultInst removed

Message

Service profile $name$ underlying resource removed

Fault Details

Severity: major
Cause: equipment-removed
Type: server

cfprFaultInst inaccessible

Message

Service profile $name$ cannot be accessed

Fault Details

Severity: major
Cause: server-inaccessible
Type: server

cfprFaultInst associationFailed

Message

Service profile $name$ association failed for $pnDn$

Fault Details

Severity: major
Cause: association-failed
Type: server

cfprFaultInst assignmentRequirementsNotMet

Message

Assignment of service profile $[ancestor:ls:Server:name]$ to server $pnDn$ failed

Fault Details

Severity: minor
Cause: assignment-failed
Type: server

cfprFaultInst unassociated

Message

Service profile $name$ is not associated

Fault Details

Severity: warning
Cause: unassociated
Type: server

cfprFaultInst svnicNotPresent

Message

Service profile $name$ does not contain service vnics for netflow.

Fault Details

Severity: warning
Cause: svnic-not-present
Type: server

cfprFaultInst server-unfulfilled

Message

Server $pnDn$ does not fulfill Service profile $name$ due to $configQualifier$

Fault Details

Severity: warning
Cause: server-failed
Type: server

cfprFaultInst unresolvableScheduler

Message

Schedule $schedName$ referenced by maintenance policy $name$ does not exist

Fault Details

Severity: warning
Cause: non-existent-scheduler
Type: server

cfprFaultInst kvmPolicyUnsupported

Message

Kvm mgmt policy not supported by current CIMC version

Fault Details

Severity: minor
Cause: unsupported-cimc-firmware
Type: server

cfprFaultInst empty

Message

MAC pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst degraded

Message

Detected non-standard memory configuration, going to failsafe mode: performance $operability$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst degraded

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst identity-unestablishable

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has an invalid FRU

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ has an invalid FRU

Fault Details

Severity: warning
Cause: identity-unestablishable
Type: equipment
 

cfprFaultInst inoperable

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$

Fault Details

Severity: major
Cause: equiment-inoperable
Type: equipment

cfprFaultInst disabled

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operState: $operState$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ operaState: $operState$

Fault Details

Severity: major
Cause: equipment-disabled
Type: equipment

cfprFaultInst thermalThresholdNonCritical

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: info
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonCritical

Message

Buffer Unit $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Buffer Unit $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: info
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdCritical

Message

Buffer Unit $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Buffer Unit $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

DIMM $location$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

DIMM $location$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Buffer Unit $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Buffer Unit $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst voltageThresholdNonCritical

Message

Memory array $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Memory array $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdCritical

Message

Memory array $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Memory array $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdNonRecoverable

Message

Memory array $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Memory array $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: critical
Cause: voltage-problem
Type: environmental

cfprFaultInst inoperable

Message

Fabric Interconnect $id$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst removed

Message

Fabric Interconnect $id$ operability: $operability$

Fault Details

Severity: critical
Cause: equipment-removed
Type: equipment

cfprFaultInst resourceStatus

Message

Vlan-Port Resource exceeded

Fault Details

Severity: critical
Cause: limit-reached
Type: management

cfprFaultInst resourceStatusWarning

Message

Total Available Vlan-Port Count on switch $switchId$ is below 10%

Fault Details

Severity: warning
Cause: near-max-limit
Type: management

cfprFaultInst inventoryFailed

Message

Fabric Interconnect $id$ inventory is not complete $inventoryStatus$

Fault Details

Severity: major
Cause: inventory-failed
Type: equipment

cfprFaultInst thermalThresholdCritical

Message

Fabric Interconnect $id$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst memoryerror

Message

Fabric Interconnect $id$ memory less than expected! Total Memory: $totalMemory$ and Expected Memory: $expectedMemory$

Fault Details

Severity: major
Cause: memory-error
Type: equipment

cfprFaultInst extraprimaryvlans

Message

Fabric Interconnect $id$: Number of primary vlans exceeds the max limit on the FI: Number of Primary Vlans: $primaryVlanCount$ and Max primary vlans allowed: $maxPrimaryVlanCount$

Fault Details

Severity: major
Cause: extra-primary-vlans
Type: equipment

cfprFaultInst extrasecondaryvlans

Message

Fabric Interconnect $id$: Number of secondary vlans exceeds the max limit on the FI: Number of secondary vlans: $secondaryVlanCount$ and Max secondary vlans allowed: $maxSecondaryVlanCount$

Fault Details

Severity: major
Cause: extra-secondary-vlans
Type: equipment

cfprFaultInst extrasecondaryvlansperprimary

Message

Number of secondary vlans associated with the primary vlan $id$ in Fabric Interconnect $switchId$ exceeds the max limit: Number of secondary vlans: $secVlanPerPrimaryVlanCount$ and Max secondary vlans allowed in a primary vlan: 30

Fault Details

Severity: minor
Cause: extra-secondary-vlans-per-primary
Type: equipment

cfprFaultInst failed

Message

Management interface is down!

Fault Details

Severity: major
Cause: port-failed
Type: network

cfprFaultInst failedBladeBootup

Message

Slot $slotId$, boot up failed - recovery in progress

Fault Details

Severity: major
Cause: bootup-failure
Type: server

cfprFaultInst failedBootupRecovery

Message

Slot $slotId$, boot up failed - exceeded max number of retrie

Fault Details

Severity: major
Cause: bootup-failure
Type: server

cfprFaultInst suspendModeActive

Message

FPRM is suspended from receiving updates from FPR Central.

Fault Details

Severity: warning
Cause: suspend-mode-entered
Type: management

cfprFaultInst duplicatedAssigned

Message

Duplicated ID is assigned for multiple blades

Fault Details

Severity: major
Cause: duplicated-assigned
Type: server

cfprFaultInst link-down

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: minor
Cause: link-down
Type: network

cfprFaultInst failed

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: minor
Cause: port-failed
Type: network

cfprFaultInst hardware-failure

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: hardware-failure

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: hardware-failure

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: hardware-failure

Fault Details

Severity: major
Cause: port-failed
Type: network

cfprFaultInst sfp-not-present

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$

Fault Details

Severity: info
Cause: port-failed
Type: network

fprFaultInst invalid-sfp

Message

$transport$ port $portId$ on chassis $[ancestor:equipment:Chassis:id]$ role : $ifRole$ transceiver type:$xcvrType$

$transport$ port $slotId$/$aggrPortId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ role : $ifRole$ transceiver type:$xcvrType$$

$transport$ port $slotId$/$portId$ on fabric interconnect $[ancestor:network:Element:id]$ role : $ifRole$ transceiver type:$xcvrType$$

Fault Details

Severity: major
Cause: unsupported-transceiver
Type: network

cfprFaultInst hardware-failure

Message

IOM $transport$ interface $portId$ on chassis $[ancestor:equipment:Chassis:id]$ oper state: $operState$, reason: $stateQual$

Fabric Interconnect $transport$ interface $portId$ on fabric interconnect $[ancestor:network:Element:id]$ oper state: $operState$, reason: $stateQual$

IOM $transport$ interface $portId$ on fex $[ancestor:equipment:Fex:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: interface-failed
Type: network

cfprFaultInst down

Message

$type$ port-channel $portId$ on fabric interconnect $switchId$ oper state: $operState$, reason: $stateQual$

$type$ port-channel $portId$ on fabric interconnect $switchId$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: operational-state-down
Type: network

cfprFaultInst down

Message

$[ancestor:fabric:DceSwSrv:type]$ port-channel $portId$ on fabric interconnect $[ancestor:fabric:DceSwSrv:id]$ oper state: $operState$, reason: $stateQual$

Fault Details

Severity: major
Cause: operational-state-down
Type: network

cfprFaultInst down

Message

$transport$ VIF $id$ on server $[ancestor:fabric:Locale:chassisId]$ / $[ancestor:compute:Blade:slotId]$ of switch $switchId$ down, reason: $stateQual$

$transport$ VIF $id$ on server $[ancestor:compute:RackUnit:id]$ of switch $switchId$ down, reason: $stateQual$

Fault Details

Severity: major
Cause: link-down
Type: network

cfprFaultInst mgmt-vif-down

Message

IOM $[ancestor:fabric:Locale:chassisId]$ / $[ancestor:fabric:Locale:slotId]$ ($switchId$) management VIF $id$ down, reason $stateQual$

Fault Details

Severity: major
Cause: cmc-vif-down
Type: network

cfprFaultInst PowerGroupCapInsufficient

Message

Chassis $id$ cannot be capped as group cap is low. Please consider raising the cap.

Fault Details

Severity: major
Cause: group-cap-insufficient
Type: environmental

cfprFaultInst ChassisFirmwareProblem

Message

Chassis $id$ cannot be capped as at least one of the CMC or CIMC or BIOS firmware version is less than 1.4. Please upgrade the firmware for cap to be applied.

Fault Details

Severity: major
Cause: old-chassis-component-firmware
Type: environmental

cfprFaultInst FirmwareMismatch

Message

Firmware on blade $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ does not allow chassis level power capping. Please consider upgrading to at least 1.4 version

Fault Details

Severity: major
Cause: old-firmware
Type: environmental

cfprFaultInst ChassisPsuInsufficient

Message

Chassis $id$ cannot be capped as at least two PSU need to be powered

Fault Details

Severity: major
Cause: psu-insufficient
Type: environmental

cfprFaultInst ChassisPsuInsufficient

Message

Chassis $[ancestor:equipment:Chassis:id]$ cannot be capped as the available PSU power is not enough for the chassis and the blades. Please correct the problem by checking input power or replace the PSU

Fault Details

Severity: major
Cause: psu-insufficient
Type: environmental

cfprFaultInst ChassisPsuRedundanceFailure

Message

Chassis $id$ was configured for redundancy, but running in a non-redundant configuration.

Fault Details

Severity: major
Cause: psu-redundancy-fail
Type: environmental

cfprFaultInst PowerBudgetCmcProblem

Message

Power cap application failed for chassis $[ancestor:equipment:Chassis:id]$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerBudgetBmcProblem

Message

Power cap application failed for server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Power cap application failed for server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerCapReachedCommit

Message

P-State lowered as consumption hit power cap for server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

P-State lowered as consumption hit power cap for server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: info
Cause: power-consumption-hit-limit
Type: environmental

cfprFaultInst TStateTransition

Message

Blade $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant

Rack server $[ancestor:compute:RackUnit:id]$ has been severely throttled. CIMC can recover if budget is redeployed to the blade or by rebooting the blade. If problem persists, please ensure that OS is ACPI compliant

Fault Details

Severity: critical
Cause: no-ack-from-bios
Type: environmental

cfprFaultInst PowerBudgetDiscFail

Message

Insufficient power available to discover server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Insufficient power available to discover server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerPolicyApplicationFail

Message

Insufficient budget to apply no-cap priority through policy $name$. Blades will continue to be capped

Fault Details

Severity: minor
Cause: no-cap-fail
Type: environmental

cfprFaultInst PowerGroupInsufficientBudget

Message

insufficient budget for power group $name$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst PowerGroupBudgetIncorrect

Message

admin committed insufficient for power group $name$, using previous value $operCommitted$

Fault Details

Severity: major
Cause: power-cap-fail
Type: environmental

cfprFaultInst ChassisPsuMixedMode

Message

Chassis $[ancestor:equipment:Chassis:id]$ has a mix of high-line and low-line PSU input power sources.

Fault Details

Severity: critical
Cause: psu-mixed-mode
Type: environmental

cfprFaultInst inoperable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst thermalNonCritical

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: info
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalCriticalThreshold

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: major
Cause: thermal-problem
Type: environmental

cfprFaultInst thermalThresholdNonRecoverable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ temperature: $thermal$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ temperature: $thermal$

Fault Details

Severity: minor
Cause: thermal-problem
Type: environmental

cfprFaultInst voltageThresholdNonCritical

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: minor
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdCritical

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: major
Cause: voltage-problem
Type: environmental

cfprFaultInst voltageThresholdNonRecoverable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ voltage: $voltage$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ voltage: $voltage$

Fault Details

Severity: critical
Cause: voltage-problem
Type: environmental

cfprFaultInst identity-unestablishable

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ has an invalid FRU

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ has an invalid FRU

Fault Details

Severity: warning
Cause: identity-unestablishable
Type: equipment

cfprFaultInst disabled

Message

Processor $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operState: $operState$

Processor $id$ on server $[ancestor:compute:RackUnit:id]$ operState: $operState$

Fault Details

Severity: major
Cause: equipment-disabled
Type: environmental
 

cfprFaultInst providergroup

Message

For $dn$: Server Group with name $name$ already exist, You need to specify a unique name for this object.

Fault Details

Severity: major
Cause: provider-group-already-exists
Type: security

cfprFaultInst providergroupsize

Message

For $dn$: Server Group $name$ has $size$ provider references. Authentication might fail, if this provider group is used with auth-domain.

Fault Details

Severity: warning
Cause: provider-group-size-empty
Type: security

cfprFaultInst servergroup

Message

For $dn$: $realm$ Server Group with name $providerGroup$ doesn't exist or is not deployed.

Fault Details

Severity: critical
Cause: invalid-server-group
Type: security

cfprFaultInst status

Message

$name$ Keyring's certificate is invalid, reason: $certStatus$.

Fault Details

Severity: major
Cause: invalid-Keyring-certificate
Type: security

cfprFaultInst modulus

Message

$name$ Keyring's RSA modulus is invalid.

Fault Details

Severity: major
Cause: invalid-Keyring-modulus
Type: security

cfprFaultInst ec

Message

$name$ Keyring's ECDSA elliptic-curve is invalid.

Fault Details

Severity: major
Cause: invalid-Keyring-ec
Type: security

cfprFaultInst status

Message

$name$ Trustpoint's cert-chain is invalid, reason: $certStatus$.

Fault Details

Severity: major
Cause: invalid-trustpoint-cert-chain
Type: security

cfprFaultInst roleNotDeployed

Message

Role $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: critical
Cause: role-config-error
Type: security

cfprFaultInst localeNotDeployed

Message

Locale $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: critical
Cause: locale-config-error
Type: security

cfprFaultInst localeOrgNotPresent

Message

Locale Org $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: warning
Cause: locale-org-config-error
Type: security

cfprFaultInst userRoleNotDeployed

Message

For user: $[ancestor:aaa:User:name]$ role $name$ can't be assigned. Error: $configStatusMessage$.

For Ldap Group: $[ancestor:aaa:LdapGroup:name]$ role $name$ can't be assigned. Error: $configStatusMessage$.

Fault Details

Severity: critical
Cause: user-role-config-error
Type: security

cfprFaultInst userLocaleNotDeployed

Message

For user: $[ancestor:aaa:User:name]$ locale $name$ can't be assigned. Error: $configStatusMessage$.

For Ldap Group: $[ancestor:aaa:LdapGroup:name]$ locale $name$ can't be assigned. Error: $configStatusMessage$.

Fault Details

Severity: critical
Cause: user-locale-config-error
Type: security

cfprFaultInst KeyRingNotDeployed

Message

Keyring $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: critical
Cause: keyring-config-error
Type: security

cfprFaultInst SyscontactEmpty

Message

FPR Manager cannot deploy an empty value of SNMP Syscontact when Callhome is enabled. The previous value $sysContact$ for SNMP Syscontact has been retained.

Fault Details

Severity: warning
Cause: snmp-config-error
Type: configuration

cfprFaultInst commTimeZoneInvalid

Message

Timezone:$timezone$ is invalid

Fault Details

Severity: minor
Cause: timezone-file-not-exists
Type: configuration
 

cfprFaultInst commNtpConfigurationFailed

Message

Ntp Configuration failed, please check the error message in Ntp host

Fault Details

Severity: major
Cause: ntp-config-failed
Type: configuration

cfprFaultInst commDeviceRegistrationPending

Message

Device registration with manager '$name$' pending.

Fault Details

Severity: info
Cause: device-registration-pending
Type: configuration

cfprFaultInst commDeviceRegistrationFailed

Message

Device registration with manager '$name$' failed, please check error messages in syslog.

Fault Details

Severity: major
Cause: device-registration-failed
Type: configuration

cfprFaultInst commDeviceUnRegistrationFailed

Message

Device unregistration with manager '$name$' failed, please check error messages in syslog.

Fault Details

Severity: major
Cause: device-unregistration-failed
Type: configuration

cfprFaultInst localUserNotDeployed

Message

Local User $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: user-config-error
Type: security

cfprFaultInst EncryptAlgoInvalid

Message

Encryption algorithm $cliEncryptAlgo$ is not supported when CC mode is enabled.

Fault Details

Severity: major
Cause: encryption-algo-not-supported
Type: configuration

cfprFaultInst snmpUserNotDeployed

Message

SNMP User $name$ can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: snmp-user-config-error
Type: configuration

cfprFaultInst commSvcNotDeployed

Message

Communication Service configuration can't be deployed. Error: $configStatusMessage$

Fault Details

Severity: major
Cause: comm-svc-config-error
Type: configuration

cfprFaultInst ipsecConnInvalidKey

Message

Invalid keyring $keyring$ for IPSec connection $name$

Fault Details

Severity: major
Cause: ipsec-config-error
Type: configuration

cfprFaultInst ipsecConnInvalidCert

Message

Invalid Cert of keyring $keyring$ for IPSec connection $name$

Fault Details

Severity: major
Cause: ipsec-config-error
Type: configuration

cfprFaultInst ipsecAuthorInvalidTp

Message

Invalid trustpoint $tpName$ for IPSec

Fault Details

Severity: major
Cause: ipsec-config-error
Type: configuration

cfprFaultInst smaHeartbeat

Message

Security module $slotId$ - network adapter 1 is not responding

Fault Details

Severity: major
Cause: slot-not-responding
Type: server

cfprFaultInst bladeNotWorking

Message

Security Module $slotId$ is in failed state. Error: $errorMsg$

Fault Details

Severity: major
Cause: blade-not-working
Type: server

cfprFaultInst diskFormatFailed

Message

Disk format is failed on slot $slotId$

Fault Details

Severity: major
Cause: disk-format-failed
Type: server

cfprFaultInst bladeSwap

Message

Blade swap detected on slot $slotId$

Fault Details

Severity: critical
Cause: blade-swap
Type: server

cfprFaultInst switchConfigFail

Message

Switch configuration failed for Logical Device. Error: $switchErrorMsg$

Fault Details

Severity: critical
Cause: switch-config-failed
Type: server

cfprFaultInst failedConversion

Message

Unrecoverable error during conversion of App Instance $appName$-$startupVersion$ on slot $[ancestor:sm:Slot:slotId]$ during FXOS upgrade

Fault Details

Severity: critical
Cause: conversion-failed
Type: server

cfprFaultInst appNotResponding

Message

App Instance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$ is not responding

Fault Details

Severity: major
Cause: appinstance-not-responding
Type: server

cfprFaultInst appInstallFailed

Message

Failed to install App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-install-failed
Type: server

cfprFaultInst appStartFailed

Message

Failed to start App Instance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-start-failed
Type: server

cfprFaultInst appUpdateFailed

Message

Failed to update App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-update-failed
Type: server

cfprFaultInst appStopFailed

Message

Failed to stop App Instance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-stop-failed
Type: server

cfprFaultInst AppInstanceError

Message

Error in App Instance $appName$-$identifier$ with version $startupVersion$ on slot $[ancestor:sm:Slot:slotId]$. $errorMsg$

Fault Details

Severity: minor
Cause: appinstance-error
Type: server

cfprFaultInst appFaultState

Message

AppInstance $appName$-$identifier$ with version $runningVersion$ on slot $[ancestor:sm:Slot:slotId]$ is in failed state. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-fault-state
Type: server

cfprFaultInst incompleteConfig

Message

Logical Device $name$ is not configured correctly. $errorMsg$

Fault Details

Severity: major
Cause: logical-device-incomplete-configuration
Type: server
 

cfprFaultInst LogicalDeviceError

Message

Error in Logical Device $name$. $errorMsg$

Fault Details

Severity: minor
Cause: logical-device-error
Type: server

cfprFaultInst licenseAgreementNotAccepted

Message

End User License Agreement not accepted for Application $name$.$version$

Fault Details

Severity: major
Cause: license-agreement-not-accepted
Type: server

cfprFaultInst appInstanceUnsupported

Message

App Instance $appName$ on slot $[ancestor:sm:Slot:slotId]$ is not supported in the current bundle. Error: $errorMsg$

Fault Details

Severity: major
Cause: appinstance-unsupported
Type: server

cfprFaultInst appImageCorrupted

Message

The application image $appId$ is corrupted

Fault Details

Severity: major
Cause: app-img-corrupted
Type: server

cfprFaultInst inoperable

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst degraded

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: warning
Cause: equipment-degraded
Type: equipment

cfprFaultInst thermalThresholdCritical

Message

SSD thermal state is $thermal$. $faultMsg$

Fault Details

Severity: critical
Cause: thermal-problem
Type: environmental

cfprFaultInst unusable

Message

Local disk $id$ on server $[ancestor:compute:Physical:serverId]$ is not usable by the operating system

Fault Details

Severity: minor
Cause: equipment-inoperable
Type: equipment

cfprFaultInst capacityExceeded

Message

Disk usage for partition $name$ on fabric interconnect $[ancestor:network:Element:id]$ exceeded 70%

Fault Details

Severity: minor
Cause: capacity-exceeded
Type: environmental

cfprFaultInst capacityWarning

Message

Disk usage for partition $name$ on fabric interconnect $[ancestor:network:Element:id]$ exceeded 90%

Fault Details

Severity: critical
Cause: capacity-exceeded
Type: environmental

cfprFaultInst filesystemIssues

Message

Partition $name$ on fabric interconnect $[ancestor:network:Element:id]$ has file system errors

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst configuration-error

Message

Flash Life on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ flashStatus: $flashStatus$

Fault Details

Severity: info
Cause: configuration-error
Type: equipment

cfprFaultInst degraded

Message

Flash Life on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ flashStatus: $flashStatus$

Fault Details

Severity: warning
Cause: equipment-degraded
Type: equipment

cfprFaultInst degraded

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst relearnAborted

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst relearnFailed

Message

RAID Battery on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

RAID Battery on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst patrolReadFailed

Message

Controller $id$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ had a patrol read failure. Reason: $operQualifierReason$

Controller $id$ on server $[ancestor:compute:RackUnit:id]$ had a patrol read failure. Reason: $operQualifierReason$

Fault Details

Severity: warning
Cause: operation-failed
Type: equipment

cfprFaultInst inoperable

Message

Controller $id$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $operQualifierReason$

Controller $id$ on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $operQualifierReason$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst rebuildFailed

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-offline
Type: equipment

cfprFaultInst copybackFailed

Message

Local disk $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Local disk $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-offline
Type: equipment

cfprFaultInst missing

Message

Local disk $id$ missing on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

Local disk $id$ missing on server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: major
Cause: equipment-missing
Type: equipment

cfprFaultInst inoperable

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: critical
Cause: equipment-inoperable
Type: equipment

cfprFaultInst degraded

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst reconstructionFailed

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst consistencyCheckFailed

Message

Virtual drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ operability: $operability$. Reason: $operQualifierReason$

Virtual drive $id$ on server $[ancestor:compute:RackUnit:id]$ operability: $operability$. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

FlexFlash Controller $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $operQualifierReason$ Status: $controllerHealth$

FlexFlash Controller $id$ on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $operQualifierReason$ Status: $controllerHealth$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst inoperable

Message

FlexFlash Card $slotNumber$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $operQualifierReason$

FlexFlash Card $slotNumber$ on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $operQualifierReason$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst missing

Message

FlexFlash Card $slotNumber$ missing on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$

FlexFlash Card $slotNumber$ missing on server $[ancestor:compute:RackUnit:id]$

Fault Details

Severity: info
Cause: equipment-missing
Type: equipment

cfprFaultInst degraded

Message

FlexFlash Virtual Drive RAID degraded on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$. Reason: $raidState$

FlexFlash Virtual Drive RAID degraded on server $[ancestor:compute:RackUnit:id]$. Reason: $raidState$

Fault Details

Severity: minor
Cause: equipment-degraded
Type: equipment

cfprFaultInst inoperable

Message

FlexFlash Virtual Drive on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is inoperable. Reason: $raidState$

FlexFlash Virtual Drive on server $[ancestor:compute:RackUnit:id]$ is inoperable. Reason: $raidState$

Fault Details

Severity: major
Cause: equipment-inoperable
Type: equipment

cfprFaultInst unhealthy

Message

FlexFlash Drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is unhealthy. Reason: $operQualifierReason$ Status: $operationState$

FlexFlash Drive $id$ on server $[ancestor:compute:RackUnit:id]$ is unhealthy. Reason: $operQualifierReason$ Status: $operationState$

Fault Details

Severity: minor
Cause: equipment-unhealthy
Type: equipment

cfprFaultInst mismatch

Message

FlexFlash Controller $id$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ has SD cards with different sizes.

FlexFlash Controller $id$ on server $[ancestor:compute:RackUnit:id]$ has SD cards with different sizes.

Fault Details

Severity: major
Cause: equipment-unhealthy
Type: equipment

cfprFaultInst unhealthy

Message

FlexFlash Drive $id$ on server $[ancestor:compute:Blade:chassisId]$/$[ancestor:compute:Blade:slotId]$ is unhealthy. Reason: $operQualifierReason$ Status: $operationState$

FlexFlash Drive $id$ on server $[ancestor:compute:RackUnit:id]$ is unhealthy. Reason: $operQualifierReason$ Status: $operationState$

Fault Details

Severity: major
Cause: equipment-unhealthy
Type: equipment

cfprFaultInst unhealthy

Message

FlexFlash Card $slotNumber$ on server $[ancestor:compute:Blade:chassisId]$ /$[ancestor:compute:Blade:slotId]$ is unhealthy. Reason: $cardHealth$

FlexFlash Card $slotNumber$ on server $[ancestor:compute:RackUnit:id]$ is unhealthy. Reason: $cardHealth$

Fault Details

Severity: minor
Cause: equipment-unhealthy
Type: equipment

cfprFaultInst disk-unidentified

Message

Disk inserted into slot $id$ unidentified

Fault Details

Severity: major
Cause: equipment
Type: equipment

cfprFaultInst sed-locked-auth-fail

Message

Local Disk $id$ is locked, please use raid add command or reboot device to unlock the disk (all data will be lost after unlock!)

Fault Details

Severity: critical
Cause: equipment
Type: equipment

cfprFaultInst sed-config-auth-fail

Message

Local Disk $id$ has no or invalid SED password, please use raid remove-secure with PSID command or reboot device to revert the disk (all data will be lost after revert!)

Fault Details

Severity: critical
Cause: equipment
Type: equipment

cfprFaultInst sed-config-sec-cmd-fail

Message

Local Disk $id$ security command failed, please reboot the device.

Fault Details

Severity: critical
Cause: equipment
Type: equipment

cfprFaultInst sed-config-sp-busy

Message

Local Disk $id$ security provider is in busy state, please reboot the device.

Fault Details

Severity: critical
Cause: equipment
Type: equipment

cfprFaultInst sed-config-disabled

Message

Local Disk $id$ self-encryption(SED) feature is disabled

Fault Details

Severity: major
Cause: equipment
Type: equipment

cfprFaultInst disk-not-sed

Message

Local Disk $id$ is not a self-encryption drive(SED)

Fault Details

Severity: major
Cause: equipment
Type: equipment

cfprFaultInst empty

Message

UUID suffix pool $name$ is empty

Fault Details

Severity: minor
Cause: empty-pool
Type: server

cfprFaultInst config-failed

Message

Eth vNIC $name$, service profile $[ancestor:ls:Server:name]$ failed to apply configuration

Fault Details

Severity: minor
Cause: configuration-failed
Type: configuration

cfprFaultInst pinningMismatch

Message

Hard pinning target for eth vNIC $name$, service profile $[ancestor:ls:Server:name]$ does not have all the required vlans configured

Fault Details

Severity: warning
Cause: pinning-mismatch
Type: configuration

cfprFaultInst pinningMisconfig

Message

Hard pinning target for eth vNIC $name$, service profile $[ancestor:ls:Server:name]$ is missing or misconfigured

Fault Details

Severity: major
Cause: pinning-misconfig
Type: configuration

cfprFaultInst vlanAccessFault

Message

The named vlan $name$ for vNIC $[ancestor:vnic:Ether:name]$ cannot be accessed from org $[ancestor:org:Org:name]$

Fault Details

Severity: major
Cause: inaccessible-vlan-referenced
Type: configuration

cfprFaultInst vlanUnresolvable

Message

The named vlan $name$ for vNIC $[ancestor:vnic:Ether:name]$ cannot be resolved$

Fault Details

Severity: warning
Cause: referenced-vlan-unresolvable
Type: configuration

cfprFaultInst remoteVlanUnresolvable

Message

The named vlan $name$ for vNIC $[ancestor:vnic:Ether:name]$ cannot be resolved remotely$

Fault Details

Severity: warning
Cause: referenced-remote-vlan-unresolvable
Type: configuration

cfprFaultInst InvalidVlan

Message

Invalid Vlan in the allowed vlan list

Fault Details

Severity: major
Cause: invalid-vlan-in-the-allowed-vlan-list
Type: configuration

cfprFaultInst vlanConflictPermit

Message

There are multiple vlans with id $id$ have different accessability configured.

Fault Details

Severity: warning
Cause: vlan-conflict-permit
Type: configuration

cfprFaultInst profileConfigIncorrect

Message

The Port Profile $name$ has an invalid configuration.

Fault Details

Severity: warning
Cause: profile-config-incorrect
Type: configuration

cfprFaultInst config-failed

Message

iSCSI vNIC $name$, service profile $[ancestor:ls:Server:name]$ has duplicate iqn name $initiatorName$

Fault Details

Severity: major
Cause: configuration-failed
Type: configuration

cfprFaultInst virtualization-conflict

Message

Multiple connection policies cannot be assigned to the same Eth vNIC

Fault Details

Severity: major
Cause: multiple-connection-policies
Type: configuration

cfprFaultInst virtualization-netflow-conflict

Message

Netflow and VMQ/SRIOV-USNIC policies cannot be assigned to the same Eth vNIC

Fault Details

Severity: major
Cause: multiple-connection-policies
Type: configuration

cfprFaultInst iscsi-config-failed

Message

Service Profile $[ancestor:ls:Server:name]$ configuration failed due to iSCSI issue $iscsiConfigIssues$

Fault Details

Severity: major
Cause: configuration-failed
Type: configuration