General
|
CLLI Code
|
Enter a string holding the CLLI code.
|
Site Address
|
Enter the site address.
|
Evolved Mesh
|
By default, this option is unchecked. When you enable this feature on the network, it is automatically enabled on the associated
sites of the network.
|
Status
|
Displays the status of the network. It shows whether the network is Up or Down.
|
Weight Lbs
|
Displays the weight of all the units of the site, in pounds.
|
Node Protection
|
Choose the Node Protection. The available options are:
-
Same shelf
-
Separated shelves
|
Mpo16Lc
|
Displays the fan-out module. The default option is MF-MPO-16LC.
The MPO-16 to 16-LC fan-out module is a double slot module with one MPO-16 connector (COM) and eight LC duplex connectors.
The MPO-16 connector is compatible with the SMR20 FS EXP and 16-AD-CCO FS units.
|
Mpo16ToMpo8 |
Choose the required Mpo16 to Mpo8 converter. The available options are:
-
MPO16ToMPO8Cable
-
MF-2MPO_ADP
|
Cascaded SMR |
Enable this option to add Layer-2 contentionless sides.
|
Flex Spectrum
|
By default, this check-box remains checked for newly created network. You cannot edit it.
|
Grooming Site |
When you enable this option, it indicates that OTN traffic can be groomed at this site.
|
MR-MXP BreakOut Cable
|
Check this check box to use the ONS-MPO-MPOLC-10 breakout cable to interconnect the client ports of the MR-MXP card with the
NCS2K-MF-MPO-20LC passive module.
|
8X10G-FO
|
Check this check box to use the NCS2K-MF-8X10G-FO passive module only for 10G on the client-side of the NCS2K-400G-XP card.
By default, this passive module is enabled.
|
Bill of Material
|
Enable NCS
|
This feature enables NCS features on all sites in the network.
|
Use PAYG
|
The Pay As You Grow (PAYG) functionality significantly reduces the initial setup cost and enables the purchase of another
wavelength capacity on a need basis.
PAYG enables port-based cost or licensing for SMR-9 and SMR-20 cards.
|
Connection Verification
|
Enable this check box to:
-
Validate the correct optical interconnection between the optical cards inside a Flex ROADM.
-
Measure the insertion loss of the external passive path.
-
Validate the quality of the connections to the patch panel.
-
Check if the insertion loss is within expected value.
The following cards support connection verification:
-
SMR20 FS CV
-
MF-DEG-5-CV
-
MF-MPO-16LC-CV
-
MF-UPG-4-CV
|
New FS-SMR PID
|
By default, this check-box remains checked for newly created network. You cannot edit it. This option enables displaying of
new SMR-20 PID in the BOM page.
You can enable this option when you unlock an mpz network where SMR-20 is selected, during upgrade or release upgrade.
|
Layout
|
Chassis Type
|
Choose the type of chassis. The available options are:
-
M6, and M15 Chassis for OLA
-
M6 Chassis for ROADM and Traffic
-
M15 Chassis for ROADM and Traffic
-
Auto for all nodes
Note
|
Chassis type is not supported for the passthrough site.
|
|
Power Supply
|
Choose the type of Power Supply. The available options are based on the chassis type:
-
Auto for all type of chassis
-
AC Power, DC power for M15 and M2 chassis
-
AC Power, DC Power, AC2 Power, DC40 Power, and DC20 Power for M6 chassis
|
Controller Card
|
Choose the type of the controller card.
For NCS 2000 site, the default controller card is TNCS-2. The available options are based on the chassis type chosen. By default,
controller cards that are supported by M15 chassis are listed. The available options are:
-
Auto
-
TNC/TSC, TNC-E/TSC-E, TNCS, TNCS-0, TNCS-2, and TNCS-20 for M2 chassis
-
TNC/TSC, TNC-E/TSC-E, TNCS, TNCS-0, TNCS-2, and TNCS-20 for M6 chassis
-
TNCS, TNCS-0 TNCS-2, TNCS-20 for M15 chassis
|
Redundant Controller Card
|
Choose whether to use a redundant controller card.
|
Layout Template
|
Choose the required layout template.
Note
|
After the chosen layout template is applied, all layout properties will be reset and disabled.
|
Note
|
After design analysis, if the applied layout template is not considered for card placement in the layout, check for the error
message (noncritical) under the Elements > Messages tab. If you see a template-related error which indicates that there is a mismatch between the cards that are defined in template
and the cards that are created on the site, perform the following:
-
Export the template from the Layout page, and modify it as required.
-
Import the modified template using the Manage > Layout Template option.
-
Switch to Design mode and apply the template to the site using the Entity Editor.
-
Reanalyze the network to get the correct layout populated.
|
|
UTS AC Power Cables
|
Choose the type of cables to be used for the AC power supply. Cables are listed based on the country type and the Chassis
type selected.
|
Redundant Power Scheme
|
Choose the redundant power scheme from the drop-down list to configure the number of working and protected power units for
the chassis.
For NCS 2000 site, the options available are based on the chassis type. For M15 chassis, the options available are 1+0, 1+1,
2+0, 2+1, 3+0, 3+1, 2+2, 3+1 is the default redundancy power scheme for M15 DC chassis and 2+2 is the default redundancy power
scheme for M15 AC chassis. For example, if you choose 3+1 redundant power scheme, there are 3 working power units and 1 protected
power unit.
For M6 chassis, the options available are Auto, Yes, and No.
|
Raman Adapter Share
|
This option is available only for the OLA site. By default, this check box remains checked. This option indicates that MF-2LC-ADP
can be shared with EDRA amplifiers and not with RAMAN amplifiers irrespective of the default selection.
|
ECU Type
|
Choose the External Connection Unit (ECU) type from the drop-down list. The options available are based on the chassis type.
By default, the ECU applicable for M15 is listed.
-
ECU—Has 12 USB 2.0 ports and supports IEEE1588v2 PTP, time-of-day (ToD), and pulse-per-second (PPS) inputs.
-
ECU-S—Similar to ECU except that it has eight USB 2.0 ports and two USB 3.0 ports.
-
ECU60-S—Variant of ECU-S introduced for the NCS 2006 when the shelf is powered at –60VDC nominal input voltage.
ECU-S and ECU60-S are supported only for M6 chassis.
|
MF Unit
|
Choose the mechanical frame for the passive optical modules from the drop-down list. The options available are Auto, MF-6RU/MF-10RU,
and MF-1RU.
-
The NCS2K-MF-1RU has four slots for the passive optical modules.
-
The NCS2K-MF-6RU supports up to 14 single-slot passive optical modules such as any combination of NCS2K-MF-DEG-5, CS2K-MF-UPG-4,
or Connection Verification (CV) units.
-
The NCS2K-MF10-6RU supports up to 10 double-slot passive optical modules such as NCS2K-MF-MPO-16LC=.
|
Chassis Disaggregation
|
If you check this check-box, ROADM and transponder cards are placed in different chassis.
|
Map
|
X Coordinate
|
It represents the longitudinal location of the site. Longitude can be positive or negative (-180 to 180). Negative is west
of Greenwich, and positive is eastward.
|
Y Coordinate
|
It represents the latitudinal location of the site. Latitude can be positive or negative (- 90–90), north and south of the
Equator.
|
Position Lock
|
Check this check box to lock the site position on the map.
|
C Band
|
Shared SMR Port
|
Check this check box to connect Contentionless unit 16-AD-CCOFS and Colored unit MD-48-ODD/Even to the same MPO port of SMR-20.
When Shared SMR port is enabled, MD-48-ODD/EVEN unit connects to the specific side of SMR-20 through MPO-8LC and UPG-4 instead
of directly connecting to SMR-20 through MPO-16LC.
Note
|
Shared SMR port becomes disabled, if
-
Degree Mesh Type property is PPMESH8-5AD
-
Or, Site Type property is SMR-9 and Scalable Upto Degree property is 8
|
|
Degree Mesh Type
|
Choose the mesh type for Flex NG-DWDM site. The available options are:
DEG-5/UPG-4 is the default value.
|
Site Type
|
Displays the type of the site. For example, OLT.
|
L0 Platform
|
Displays the platform.
|
Degree Type
|
Displays the type of degree. For example, BRK-8.
|
Pre Equip Degree
|
This parameter determines the number of degrees to be considered for the site hardware placement on day 0.
The values can be None, Auto, 4, 8, 12 or 16. The default option is None. If you choose None, only the sides that are present
in the Cisco ONP GUI are shown. The values in the drop-down list are populated based on the value of scalable up to degree parameter.
|
SVO
|
Chassis License Flush Out
|
Allows you to flush out the existing chassis license and purchase new chassis license.
|
SVO Pluggables
|
You can choose one of the following options from the drop-down list. When you choose Auto, ONS_SC+-10G_SR is the default option.
-
Auto
-
ONS-SC +- 10G-SR
-
ONS-SC +-10G-LR
Note
|
The SVO pluggables are not applicable for UCS-based SVO network design.
|
|
Cisco NMS
|
SVO Full License
|
Enable this check box to add High Availability (Feature and License), Connection Verification license, Flex Spectrum license,
and OTDR license packaged in it.
|
High Availability
|
Enable this check box to add the High Availability feature to the license package.
|
Connection Verification License
|
Enable this check box to add the Connection Verification feature to the license package.
|
Flex Spectrum License
|
Enable this check box to add the Flex Spectrum feature to the license package. For SSON networks, Flex Spectrum license is
enabled by default.
|
OTDR License
|
Enable this check box to add the OTDR feature to the license package.
|
3rd party NMS
|
3rd party Full License
|
Enable this check box to add NBI (North Bound Interface), Alarm Correlation, Performance Monitoring, and Circuit Provisioning
features to the license package.
|
NBI
|
Enable this check box to add the NBI feature to the license package.
|
Alarm Correlation
|
Enable this check box to add the Alarm Correlation feature to the license package.
|
Performance Monitoring
|
Enable this check box to add the Performance Monitoring feature to the license package.
|
Circuit Provisioning
|
Enable this check box to add the Circuit Provisioning feature to the license package.
|