- About this Guide
- Chapter 1, Install the Shelf and Backplane Cable
- Chapter 2, Install Cards and Fiber-Optic Cable
- Chapter 3, Connect the PC and Log Into the GUI
- Chapter 4, Turn Up a Node
- Chapter 5, Turn Up a Network
- Chapter 6, Create Circuits and VT Tunnels
- Chapter 7, Manage Circuits
- Chapter 8, Manage Alarms
- Chapter 9, Monitor Performance
- Chapter 10, Change Card Settings
- Chapter 11, Change Node Settings
- Chapter 12, Upgrade Cards and Spans
- Chapter 13, Convert Network Configurations
- Chapter 14, Add and Remove Nodes
- Chapter 15, Maintain the Node
- Chapter 16, Power Down the Node
- Chapter 17, DLPs A1 to A99
- Chapter 18, DLPs A100 to A199
- Chapter 19, DLPs A200 to A299
- Chapter 20, DLPs A300 to A399
- Chapter 21, DLPs A400 to A499
- Chapter 22, DLPs A500 to A599
- Chapter 23, DLPs A600 to A699
- Appendix A, CTC Information and Shortcuts
- Before You Begin
- NTP-A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
- NTP-A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards
- NTP-A118 Modify Alarm Interface Controller-International Settings
- NTP-A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection
- NTP-A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards
- NTP-A321 Change Card or PPM Service State
- NTP-A322 Manage Pluggable Port Modules
- NTP-A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards
Change Card Settings
This chapter explains how to change line provisioning, thresholds, service states, and line rates on Cisco ONS 15454 cards.
Before You Begin
Before performing any of the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15454 Troubleshooting Guide as necessary.
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1. A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards—As needed, complete this procedure to change line and threshold settings for all electrical cards (EC-1, DS-1, DS-3, DS3i-N-12, and DS3XM).
2. A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards—As needed, complete this procedure to change line and threshold settings for all optical cards.
3. A118 Modify Alarm Interface Controller-International Settings—As needed, complete this procedure to change external alarms and controls and/or orderwire settings.
4. A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection—As needed, complete this procedure to change the protection type on DS-1 or DS-3 cards.
5. A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards—As needed, complete this procedure to change FC_MR-4 card port and threshold settings.
6. A321 Change Card or PPM Service State—As needed, complete this procedure to change the service state on a card or pluggable port module (PPM).
7. A322 Manage Pluggable Port Modules—As needed, complete this procedure to provision a multirate PPM, assign the optical line rate, change the optical line rate, and delete PPMs.
8. A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards—As needed, complete this procedure to provision the node's cross-connect mode if mixed mode grooming is required.
NTP-A88 Modify Line Settings and PM Parameter Thresholds for Electrical Cards
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to change the electrical card settings. If you are already logged in, proceed to Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Step 3 Perform any of the following tasks as needed:
•A165 Change Line and Threshold Settings for a DS1-14 or DS1N-14 Card
•A166 Change Line and Threshold Settings for a DS3-12 or DS3N-12 Card
•A167 Change Line and Threshold Settings for a DS3E-12 or DS3N-12E Card
•A168 Change Line and Threshold Settings for the DS3XM-6 Card
•A387 Change Line and Threshold Settings for the DS3XM-12 Card
•A526 Change Line and Threshold Settings for the DS3i-N-12 Cards
•A388 Change Line and Threshold Settings for the DS3/EC1-48 Cards
•A169 Change Line and Threshold Settings for the EC1-12 Card
•A376 Change Line and Threshold Settings for the DS1/E1-56 Cards
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-A89 Modify Line Settings and PM Parameter Thresholds for Optical Cards
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to change the OC-N card settings. If you are already logged in, proceed to Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Step 3 Perform any of the following tasks as needed:
•A379 Change Line Transmission Settings for OC-N Cards
•A171 Change Threshold Settings for OC-N Cards
•A459 Change Optics Thresholds Settings for OC-192 and MRC-12 Cards
•A527 Change the OC-N Card ALS Maintenance Settings
•A172 Change an Optical Port to SDH
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-A118 Modify Alarm Interface Controller-International Settings
Purpose |
This procedure provisions the AIC-I card to receive input from or send output to external devices wired to the backplane (called external alarms and controls or environmental alarms). It also changes orderwire settings. |
Tools/Equipment |
None |
Prerequisite Procedures |
A258 Provision External Alarms and Controls on the Alarm Interface Controller-International |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite or remote |
Security Level |
Provisioning or higher |
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to change the AIC-I card settings. If you are already logged in, continue with Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Step 3 Perform any of the following tasks as needed:
•A208 Change External Alarms Using the AIC-I Card
•A209 Change External Controls Using the AIC-I Card
•A210 Change AIC-I Card Orderwire Settings
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-A91 Upgrade DS-1 and DS-3 Protect Cards from 1:1 Protection to 1:N Protection
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to convert the DS-1 or DS-3 cards from 1:1 to 1:N protection. If you are already logged in, continue with Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Step 3 Perform any of the following tasks as needed:
•A176 Convert DS1-14 Cards From 1:1 to 1:N Protection
•A177 Convert DS3-12 Cards From 1:1 to 1:N Protection
•A178 Convert DS3-12E Cards From 1:1 to 1:N Protection
•A448 Convert DS3XM-6 or DS3XM-12 Cards From 1:1 to 1:N Protection
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-A315 Modify Port Settings and PM Parameter Thresholds for FC_MR-4 Cards
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to change the OC-N card settings. If you are already logged in, continue with Step 2.
Step 2 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Step 3 Perform any of the following tasks as needed:
•A438 Change General Port Settings for the FC_MR-4 Card
•A439 Change Distance Extension Port Settings for the FC_MR-4 Card
•A440 Change Enhanced FC/FICON Port Settings for the FC_MR-4 Card
•A357 Create FC_MR-4 RMON Alarm Thresholds
•A358 Delete FC_MR-4 RMON Alarm Thresholds
Step 4 As needed, complete the "NTP-A108 Back Up the Database" procedure.
Stop. You have completed this procedure.
NTP-A321 Change Card or PPM Service State
Note On the OC192-XFP and MRC-12 cards, the pluggable-port module (PPM) is equivalent to an optical port.
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to change the card service state.
Step 2 From node view, click the Inventory tab.
Step 3 Choose an Admin state from the Admin State drop-down list for the card or PPM that you want to change: IS (In-Service) or OOS,MT (Out-of-Service,Maintenance).
Step 4 Click Apply.
Step 5 If an error message appears indicating that the card state cannot be changed from its current state, click OK.
Depending on the Admin State you choose, the card or port/PPM transitions to a different service state. For more information about the service states and card state transitions, refer to the "Administrative and Service States" appendix of the Cisco ONS 15454 Reference Manual.
Stop. You have completed this procedure.
NTP-A322 Manage Pluggable Port Modules
Purpose |
This procedure provisions, changes, and deletes pluggable port modules (PPMs) for the MRC-12 and OC192-XFP cards. (OC-192XFPs are single-rate PPMs, and therefore can only be deleted.) |
Tools/Equipment |
None |
Prerequisite Procedures |
A461 Preprovision an SFP or XFP Device or |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite or remote |
Security Level |
Provisioning or higher |
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to provision, change, or delete PPMs. If you are already logged in, continue with Step 2.
Step 2 From the View menu, choose Go to Network View.
Step 3 Click the Alarms tab:
a. Verify that the alarm filter is not turned on. See the "DLP-A227 Disable Alarm Filtering" task as necessary.
b. Verify that no unexplained conditions appear on the network. If unexplained conditions appear, resolve them before continuing. Refer to the Cisco ONS 15454 Troubleshooting Guide.
c. Complete the "DLP-A532 Export CTC Data" task to export alarm and condition information.
Step 4 As needed, complete the "DLP-A444 Provision a PPM on the MRC-12 Card" task. Single-rate PPMs do not require provisioning.
Step 5 As needed, complete the "DLP-A445 Provision the Optical Line Rate on the MRC-12 Card" task to assign an OC-3, OC-12, or OC-48 line rate to a multirate PPM.
Step 6 As needed, complete the "DLP-A446 Change the Optical Line Rate on the MRC-12 Card" task to change the line rate on a multirate PPM. You cannot change the optical line rate on single-rate PPMs.
Step 7 As needed, complete the "DLP-A447 Delete a PPM from the MRC-12 or OC192-XFP Card" task.
Stop. You have completed this procedure.
NTP-A354 Set or Check Cross-Connect Mode for XC-VXC-10G Cards
Step 1 Complete the "DLP-A60 Log into CTC" task at the node where you want to change the XC-VXC-10G card settings. If you are already logged in, continue with Step 2.
Step 2 Navigate to the node view in CTC.
Step 3 Click Provisioning > Cross-Connect. The Cross-Connect dialog box is displayed.
Step 4 If necessary, click the Mixed Mode radio button in the Cross-Connect dialog box and click Apply.
Stop. You have completed this procedure.