- Finding Feature Information
- Information About Cisco Data Collection Manager
- How to Configure Cisco Data Collection Manager
- Configuring an SNMP Bulkstat Data Set
- Configuring an SNMP BulkStat Instance Set
- Configuring an SNMP BulkStat Filter Set
- Configuring a Command BulkStat Data Set
- Configuring a BulkStat Data Group
- Configuring a Bulkstat Profile
- Configuring Bulkstat Calendar Scheduling
- Configuring a Bulkstat Resource Limit
- Configuration Examples for Cisco Data Collection Manager
- Additional References for Cisco Data Collection Manager
- Feature Information for Cisco Data Collection Manager
- Glossary
Cisco Data Collection Manager
The Cisco Data Collection Manager (DCM) feature provides a scalable data collection framework for collecting data from Cisco devices. The DCM supports a profile-based configuration that allows users to set parameters for collecting, processing, and exporting the data. The DCM also supports a flexible data process mechanism that allows users to derive information from raw data, and calculate baselines, summaries, statistical distribution, and percentiles. The integrated monitoring feature of DCM allows users to monitor multiple data sources, such as Simple Network Management Protocol (SNMP) MIB objects and show command output. The DCM supports the export of collected data based on transfer configurations through multiple data export mechanisms, such as FTP, TFTP, and Internet Protocol Flow Information Export (IPFIX).
- Finding Feature Information
- Information About Cisco Data Collection Manager
- How to Configure Cisco Data Collection Manager
- Configuration Examples for Cisco Data Collection Manager
- Additional References for Cisco Data Collection Manager
- Feature Information for Cisco Data Collection Manager
- Glossary
Finding Feature Information
Your software release may not support all the features documented in this module. For the latest caveats and feature information, see Bug Search Tool and the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the feature information table.
Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to www.cisco.com/go/cfn. An account on Cisco.com is not required.
Information About Cisco Data Collection Manager
Cisco Data Collection Manager
Overview of Cisco Data Collection Manager
Cisco Data Collection Manager (DCM) is an efficient and reliable data collection agent that is embedded in managed devices, such as routers and switches. DCM works on a push model, which is based on a subscribe-and-notify data pattern, as opposed to the pull model, which is based on a request-and-response data pattern, in traditional SNMP-based network management.
Configuration and Deployment
The Bulkstat client application is implemented using the DCM core services to retrieve data and export it to the user. The Bulkstat client provides the only available user interface for DCM access. The client also provides CLI access through a new set of configuration commands and MIB access through the CISCO-DATA-COLLECTION-MIB. You can configure the data to be exported as a file. Also, you can configure the data to be processed and the processed file to be collected by the NMS.
Data Collection
The Data Collection Manager (DCM) provides data subscription services for multiple data sources, such as the Simple Network Management Protocol (SNMP) MIB objects and the output of show commands. The DCM allows you to configure the data that needs to be collected. The DCM also allows you to specify when and at what interval the data should be collected.
Data Processing
The Data Collection Manager (DCM) supports advanced on-board data processing that includes baseline calculation, summary calculation, statistical distribution, and percentile computation. The DCM is integrated with CISCO-EXPRESSION-MIB to externally create and customize MIB objects for monitoring and to support the CLI to define expressions.
Data Export and Retrieval
The Data Collection Manager (DCM) provides data retrieval management to ensure that the data collection does not impact device resources. The DCM can export data in a file format using multiple export protocols such as FTP, TFTP, Secure copy protocol (SCP), and Secure File Transfer Protocol (SFTP). The DCM provides a query mechanism with which data can be selectively exported based on the configured time interval and other selection criteria. The DCM application also provides data filtering services and exports the filtered data. You can also set primary and secondary destinations for exporting the collected data in a raw or processed format. Snapshots of the collected data can be stored for later retrieval.
Performance Management Solutions
The Data Collection Manager (DCM) can be used to manage various aspects of performance management. The following list provides a few scenarios.
Traffic Engineering
The primary goal of traffic engineering is to control traffic flow and provide Class of Service (CoS) and Quality of Service (QoS) to the end user, while using network resources optimally. It is the responsibility of the network management server (NMS) to provide low-level management through traffic conditioning, packet shaping, queue management, and other functions that regulate traffic flow through the network. The DCM can be used to collect data with a high granularity to help the NMS make dynamic traffic engineering decisions.
Capacity Planning and Trend Analysis
The key priorities for network operators today are acceleration in new service introduction, reduction in the complexity of deployment and management of services, and reduction in the capital or operational overhead expenditure. These services require unique capabilities that are specific to a particular network operator and the ability to provide specific service characteristics on a per-consumer basis. It is important to identify trends in the network traffic, forecast future traffic levels, assess whether the existing network capacity is sufficient to handle the projected load, and automatically redesign the network to support future traffic demands. The DCM can be used to collect resource variables that are important for effective capacity trend information, such as memory, queue depth, broadcast volume, buffer, Frame Relay congestion notification, and backplane utilization.
Diagnostics
The streaming function of the DCM can be used for real-time troubleshooting. Also, the DCM facilitates data retrieval for selective periods and aids in troubleshooting.
SLA Management
A service level agreement (SLA) includes a what-if analysis for network changes and application changes, baselining and trending for defined performance variables, exception management for defined capacity and performance variables, and QoS management. The DCM can be used to collect periodic data for reporting purposes.
Bulkstat
Two challenges that network providers usually face are data gathering and data analysis. Network providers need to gather large volumes of data to analyze the performance of the network and to have operational control over their network. Large service providers are strengthening their data gathering and analysis infrastructure. Traditionally, Simple Network Management Protocol (SNMP) agents are used to expose management data on managed systems. But, SNMP is not well suited for gathering large volumes of data, especially over short time intervals.
For example, service providers charge customers depending on the network usage. Also this data must be available on customer request. Accounting applications based on SNMP polling models consume significant network bandwidth because they poll large volumes of data frequently. The SNMP protocol data unit (PDU) is a complex data type specific to SNMP and is expensive to process because the SNMP objects and tables must be sorted in a lexicographic order. All the entries in SNMP MIB tables are lexicographically ordered by their object identifiers, because there is an implied ordering in the MIB based on the order of the object identifiers.
In such cases, the need to continuously poll large or bulk SNMP statistics can be avoided by using applications known as collectors to retrieve data.
The Bulkstat application is one such collector that uses the services of the Data Collection Manager (DCM) to provide the following functions:
-
Collecting SNMP MIB object values and the output of show commands.
-
Processing the collected data to create summary, percentiles, and auto-baselined values.
-
Exporting collected data through simple file transfer.
-
Scheduling calendar events for data collection and export.
The Bulkstat application provides command-line access through a set of new configuration commands and exclusive MIB access through CISCO-DATA-COLLECTION-MIB to collect SNMP data.
You can configure Bulkstat for the following functions:
-
Specify the way Bulkstat retrieves bulk statistics.
-
Specify the time interval in seconds at which Bulkstat transfers data to receivers.
-
Specify the maximum size of the bulk statistics file.
-
Specify the context, instance, and period at which the system retrieves bulk statistics.
-
Configure file-related parameters.
-
Configure the interface type on which you want to collect statistics.
-
View the parameters that Bulkstat uses to collect statistics by using the show bulkstat commands.
Bulkstat Configuration Elements
The following list shows the elements that you can configure using the Bulkstat interface:
Data Set
This section describes the data set elements that you can configure to collect Simple Network Management Protocol (SNMP) data and CLI data. Only objects having the same index elements can be grouped in a single object list.
SNMP Data
The SNMP data set contains the following fields:
Name |
Description |
Configuration Status |
---|---|---|
Objects |
Specifies the object to be collected. Multiple objects can be configured to form a data set. The textual name of the object can be used for configuring an object. If the device does not recognize the textual name, the object identifier (OID) format can be used for configuring the name. |
Mandatory |
Object alias |
Specifies the optional alias name that each object can have. |
Optional |
Note | Only objects having the same index elements can be grouped in a single data set. For example, the objects ifDescr and cieIfSpeedReceive belong to different tables, but they are indexed by ifIndex. Hence the two objects can be grouped in the same data set. ifDescr and entPhysicalDescr cannot be grouped in the same data set, because ifDescr is indexed by ifIndex and entPhysicalDescr is indexed by entPhysicalIndex. Objects from tables having sparse dependency can also be grouped in the same data set. Similar SNMP data elements can be linked to multiple subscriptions. Each subscription can collect different entries for the objects based on the instance configuration and context configuration. |
CLI Data
The CLI data set contains the following fields:
Name |
Description |
Configuration Status |
---|---|---|
CLI |
Specifies the CLI command for which the show output needs to be collected. More than one CLI can be specified in the same data set. |
Mandatory |
Instance Set
This section specifies the instance set elements that you can configure to collect Simple Network Management Protocol (SNMP) data. More than one instance of the same type can be added to the set. Combinations of types of instance set elements are not supported.
The SNMP Instance set contains the following fields:
Name |
Description |
Configuration Status |
---|---|---|
Exact |
Specifies the instance for which the data should be collected. More than one instance can be specified, but only fully qualified instances should be specified. |
Optional |
Wildcard |
Specifies all instances for all objects under the object configured in the data set. |
Optional |
Range |
Specifies the start and end instances. All instances within the range, including the start and end, are collected, but only fully qualified instances should be specified. |
Optional |
Repetition |
Specifies the start of the repetition and the number of repetitions. All instances from the start until the number of repetitions within the subtree are collected. |
Optional |
Interface |
Specifies the interface instead of the index. The ifIndex assigned to the interface will be used as an index. This can be used for MIB objects indexed by ifIndex. |
Optional |
Filter Set
This section describes the filter configuration per object.
The filter set elements that you can configure to collect Simple Network Management Protocol (SNMP) data are described here. More than one filter of the same type can be added to the set.
Name |
Description |
Status |
---|---|---|
Object match |
Specifies the value to be used to match against the value retrieved for the object during collection. The value provided needs to match the type of the object. If there is an error in the type matching, the configuration is not accepted. More than one value can be specified for an object, and more than one object can have matching values. |
Optional |
Process Set
For detailed information, see the topic “Data Processing.”
Data Group
This section describes the data group, which contains the data-group name, data-group type, data set, instance set, filter set, polling interval, SNMP context, and other processing options.
Data Profile
This section describes the data profile that is used to group multiple data groups. This is done to simplify the configuration and to aggregate data of similar nature. A data profile can have multiple data groups. A data group can have constraints in the data specified in the element. If two sets of data need to be written to the same file, the respective data groups should be linked as part of a single profile.
The data profile has the following fields:
Name |
Description |
Status |
---|---|---|
Data groups |
Specifies the data group to be linked to this profile. Multiple data groups can be linked to a single profile. |
Mandatory before activating a profile |
Transfer interval |
Specifies the transfer periodic interval in seconds. In case of recurring transfer, the data is transferred when the transfer interval expires. |
Optional Default interval transfer raw data is 1800. |
Process interval |
Specifies the process periodic interval in seconds. The data is processed during every collection interval as soon as it is collected. When the process interval expires, the processed data is written into a file and transferred. |
Optional Default interval transfer processes data is 3600. |
Primary URL |
Specifies the URL of the primary management station. The files containing the collected data are transferred to this URL when the transfer interval expires. |
Mandatory |
Secondary URL |
Specifies the URL of the secondary management station to be used in case the transfer to the primary management station fails. |
Optional |
Schema |
Specifies the file data format. The schemaASCII option is supported. |
Optional Default format is schemaAscii. |
Retry |
Specifies the number of times that the transfer is retried in case of transfer failures to both primary and secondary management stations. This command has an effect only if the retain command is configured in the profile. The retry interval is computed by dividing the retention time by the number of retries. For example, if the file is retained for 60 minutes and the retry is 6 times, the transfer is attempted every 10 minutes, until the transfer succeeds or the file is removed. |
Optional Default retry value is retry is 3. |
Buffer-size |
Specifies the maximum size to which the file containing the collected data can grow. When it reaches the limit, the file is closed and the transfer is attempted based on the transfer configuration associated with the data group or profile. |
Optional |
Retention memory |
Specifies the time, in seconds, to retain the file in the memory. |
Optional |
Retention USB |
Specifies the time, in seconds, to retain the file in the USB. This option is available only if the device supports the USB drive. |
Optional |
Resource Limit
The Bulkstat application allows you to configure memory resource limit in percentage. Bulkstat will deactivate all profiles if the remaining memory is less than specified limit.
By default, the resource limit is set at 95 percentage of the total available memory to accommodate for high memory usage on certain platforms.
Calendar Scheduling
The Bulkstat application allows you to schedule each subscription for collection. A subscription can be scheduled for one-time collection or periodic collection. A periodic subscription can be repeated infinitely or for a specified number of repetitions. A timer is instantiated for every activated subscription.
Name |
Description |
Configuration Status |
---|---|---|
One shot |
Specifies that the data is collected for a specified collection interval. |
Optional |
Recurring |
Specifies that the data is collected regularly at the specified time, day, month, and for a specified collection interval. |
Optional |
Predefined Data Sets and Data Groups
In NG3K devices, a Simple Network Management Protocol (SNMP) MIB table having large number of objects will result in large number of lines of bulkstat configuration needed to collect these objects. For example, if the SNMP table contains 40 objects, then we need 41 lines of configuration for bulkstat data set, 2 lines for an instance set and a minimum of 3 lines for a data group. So, there would be a total of 46 lines of configuration required to collect a SNMP table containing 40 objects. This can slow down the system as it takes a longer time to generate the output of Cisco IOS nonvolatile generation commands and results in a large output.
Configuring predefined data-sets and data-groups as required by the users is a solution for this issue as predefined configurations do not appear in the output of show bulkstat commands. The predefined data-sets, data-groups, and instance-sets would be present only if all the SNMP objects in the set are present in the SNMP table.
Note |
|
Following is an example of predefined data-sets and data-groups:
-
bulkstat data _pd_MobileStationDS type snmp
-
bulkstat data _pd_MobileStationStatsDS type snmp
-
bulkstat data _pd_ClientDS type snmp
-
bulkstat data _pd_MobilityDS type snmp
-
bulkstat data-group _pd_MobileStationDG
-
bulkstat data-group _pd_MobileStationStatsDG
-
bulkstat data-group _pd_ClientDG
-
bulkstat data-group _pd_MobilityDG
Displaying Predefined Configurations
The following three commands are used to display the predefined data-sets and data-groups:
SNMP Data Collection
The Data Collection Manager (DCM) is used to collect the Simple Network Management Protocol (SNMP) MIB Object data. This collection is supported through both Bulkstat CLI and CISCO-DATA-COLLECTION-MIB. This allows a network management server (NMS) application to configure a set of MIB objects and a set of instances whose values need to be collected on a periodic basis. You can configure the collected data to be periodically sent to the NMS through file export.
CLI Data Collection
You can configure the Data Collection Manager (DCM) module to collect show command output through the Bulkstat CLI. The DCM captures the raw show command output and periodically exports the data through the ASCII file format.
Data Processing
Data processing allows users to derive information from raw SNMP data, by calculating summaries and percentiles.
Service providers rely on monitored SNMP data to alert network management systems (NMSs) of changing network conditions. By periodically monitoring the device data and comparing it against a set of thresholds, the network can automatically alert the operators, thereby allowing efficient operations.
Summary
You can enable summary processing on the collected object value and calculate minimum, maximum, and average values. A summary is calculated for only those objects that are marked as process capable in the data group and uses the absolute or delta value as per the object configuration.
Distribution
You can enable distribution processing on the collected object value by specifying the object type, minimum value, maximum value, and the number of buckets to distribute the value. Based on the configuration, counters are maintained per bucket and are incremented whenever the data falls into a bucket range.
Percentile
You can enable percentile processing on the collected object value. A percentile is calculated on every process interval expiry. Distribution configuration is mandatory to enable percentile processing. Percentile computation is done assuming that the distribution is normal.
Auto-baseline
You can enable baseline processing on the collected object value. The baseline internally uses all summary, distribution, and percentile calculations to provide baseline values. You can configure either baseline processing or other forms of processing, such as summary, distribution, and percentile calculations.
The auto-baseline feature in DCM calculates the baseline values for variables of interest on the device and allows network management applications or network operators to retrieve the baseline values. The baseline values can be displayed in terms of percentiles or a median with standard deviation.
File Data Export
The file data export feature on the Data Collection Manager (DCM) exports the collected data based on the transfer configurations. Data can be exported in various formats, and Bulkstat files are one such format to collect data. The format in which the data is inserted into the file conforms to the schemaAscii format described in CISCO-DATA-COLLECTION-MIB and CISCO-BULK-FILE-MIB. The data sequence in which the data is stored is determined based on the sequence in which the data is received.
The Cisco File Transfer module is responsible for transferring the files as per the transfer configuration. This module interfaces with the Cisco IOS IFS module to transfer the file to the specified URL. A file can be retained in the device whether the transfer was a success or a failure.
File names are created using the following format:
How to Configure Cisco Data Collection Manager
Configuring an SNMP Bulkstat Data Set
The first step in configuring the Simple Network Management Protocol (SNMP) periodic data collection and transfer mechanism is to configure one or more data sets. A data set is used to group objects of similar types, based on the data source. The data set is defined outside of the data group. This external definition gives the user the flexibility to use the same data set across multiple data groups and to collect the output for different instances and different contexts.
Note | All objects in an SNMP data set must be indexed by the same MIB index. However, the objects in the data set must not belong to the same MIB or the MIB table. |
Perform this task to configure the SNMP Bulkstat data set.
1.
enable
2.
configure
terminal
3.
bulkstat
data
data-set-name
type
snmp
4.
object
oid [alias
alias-name]
5.
end
DETAILED STEPS
Command or Action | Purpose | |||
---|---|---|---|---|
Step 1 |
enable
Example: Device> enable |
Enables privileged EXEC mode. | ||
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. | ||
Step 3 |
bulkstat
data
data-set-name
type
snmp
Example: Device(config)# bulkstat data interface-stats type snmp |
Defines an SNMP Bulkstat data set and enters SNMP bulk statistics data set configuration mode. The creation of an SNMP Bulkstat data set creates a row in the cdcDGBaseObjectEntry table in the SNMP MIB.
| ||
Step 4 |
object
oid [alias
alias-name]
Example: Device(config-bs-ds-snmp)# object 1.3.6.1.2.1.2.2.1.11 Example: Device(config-bs-ds-snmp)# object ifDescr Example: Device(config-bs-ds-snmp)# object ifInOctets Example: Device(config-bs-ds-snmp)# object 1.3.6.1.2.1.2.2.1.10 alias ifInOctets Example: Device(config-bs-ds-snmp)# object 1.3.6.1.2.1.2.2.1.10 alias interfaceInBytes |
Adds a MIB object to the SNMP Bulkstat data set. If the object is already present in the data set, this command replaces the old object configuration with the new configuration. | ||
Step 5 |
end
Example: Device(config-bs-ds-snmp)# end |
Exits SNMP Bulkstat data set configuration mode and returns to privileged EXEC mode. |
Configuring an SNMP BulkStat Instance Set
The Simple Network Management Protocol (SNMP) instance set specifies the instances for which the data should be collected. Each subscription can collect different entries for specified objects based on the instance configuration. While more than one instance of the same type can be added to the instance set, a combination of different types is not supported.
Perform this task to configure the SNMP Bulkstat instance set.
1.
enable
2.
configure
terminal
3.
bulkstat
instance
instance-set-name
type
snmp
4.
exact
oid
oid
5.
exact
interface
interface-id
6.
wildcard
7.
wildcard
oid
oid
8.
wildcard
interface
interface-id
9.
repetition
oid
oid
max
value
10.
range
start
oid
end
oid
11.
end
DETAILED STEPS
Command or Action | Purpose | |||||
---|---|---|---|---|---|---|
Step 1 |
enable
Example: Device> enable |
Enables privileged EXEC mode. | ||||
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. | ||||
Step 3 |
bulkstat
instance
instance-set-name
type
snmp
Example: Device(config)# bulkstat instance exact type snmp |
Defines an SNMP Bulkstat instance set and enters SNMP Bulkstat instance set configuration mode. The creation of an SNMP Bulkstat instance set creates a row in the cdcDGInstanceEntry table in the SNMP MIB.
| ||||
Step 4 | exact
oid
oid
Example: Device(config-bs-is-snmp)# exact oid 1.2.3 Example: Device(config-bs-is-snmp)# exact oid 1 |
(Optional) Indicates that the specified instance, when appended to the object list, is the complete OID. | ||||
Step 5 | exact
interface
interface-id
Example: Device(config-bs-is-snmp)# exact interface Gigabitethernet 0/0 sub-if |
(Optional) Specifies an interface name and number, for example interface Ethernet 0, instead of specifying the ifIndex OID for the interface. | ||||
Step 6 | wildcard
Example: Device(config-bs-is-snmp)# wildcard |
(Optional) Specifies whether an object used for evaluating an expression is to be wildcarded during an event configuration. | ||||
Step 7 | wildcard
oid
oid
Example: Device(config-bs-is-snmp)# wildcard oid 1.2.3 Example: Device(config-bs-is-snmp)# wildcard oid 1 |
(Optional) Indicates that all subindices of the specified OID belong to this schema. | ||||
Step 8 | wildcard
interface
interface-id
Example: Device(config-bs-is-snmp)# wildcard interface Gigabitethernet 0/0 sub-if |
(Optional) Specifies an interface name and number, for example interface Ethernet 0, instead of specifying the ifIndex OID for the interface. | ||||
Step 9 | repetition
oid
oid
max
value
Example: Device(config-bs-is-snmp)# repetition oid 1.2.3.4 max 2000 |
(Optional) Configures data collection to repeat get-next for the maximum number of instances starting from the specified oid instance. | ||||
Step 10 | range
start
oid
end
oid
Example: Device(config-bs-is-snmp)# range start 1.2.3.4 end 1.2.3.6 |
(Optional) Configures a range of instances for which the data is collected. | ||||
Step 11 |
end
Example: Device(config-bs-is-snmp)# end |
Exits SNMP Bulkstat instance set configuration mode and returns to privileged EXEC mode. |
Configuring an SNMP BulkStat Filter Set
The Simple Network Management Protocol (SNMP) filter set specifies the filter configuration for every SNMP object.
Perform this task to configure the SNMP Bulkstat filter set.
1.
enable
2.
configure
terminal
3.
bulkstat
filter
filter-set-name
4.
match
object-name
{eq
line
|
start
line
| not
{eq
line
|
start
line}}
5.
end
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 |
enable
Example: Device> enable |
Enables privileged EXEC mode. |
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. |
Step 3 |
bulkstat
filter
filter-set-name
Example: Device(config)# bulkstat filter ifType |
Defines an SNMP Bulkstat filter set and enters SNMP Bulkstat filter set configuration mode. |
Step 4 |
match
object-name
{eq
line
|
start
line
| not
{eq
line
|
start
line}}
Example: Device(config-bs-fs)# match ifType eq 6767 Example: Device(config-bs-fs)# match ifDescr start "Ethernet" Example: Device(config-bs-fs)# match ifType not eq 2 |
(Optional) Specifies a value to be used to match against the value retrieved for the object during collection. |
Step 5 |
end
Example: Device(config-bs-fs)# end |
Exits SNMP Bulkstat filter set configuration mode and returns to privileged EXEC mode. |
Configuring a Command BulkStat Data Set
The command Bulkstat data set specifies the show commands for which the output is to be collected. You can specify more than one command in the same data set.
Perform this task to add show commands.
1.
enable
2.
configure
terminal
3.
bulkstat
data
data-set-name
type
command
4.
add
cmd
command-line
5.
end
DETAILED STEPS
Command or Action | Purpose | |||
---|---|---|---|---|
Step 1 |
enable
Example: Device> enable |
Enables privileged EXEC mode. | ||
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. | ||
Step 3 |
bulkstat
data
data-set-name
type
command
Example: Device(config)# bulkstat data show-snmp type command |
Defines a command Bulkstat data set and enters command Bulkstat data set configuration mode.
| ||
Step 4 | add
cmd
command-line
Example: Device(config-bs-ds-cmd)# add cmd show snmp Example: Device(config-bs-ds-cmd)# add cmd show ip interface brief |
| ||
Step 5 |
end
Example: Device(config-bs-ds-cmd)# end |
Exits command Bulkstat data set configuration mode and returns to privileged EXEC mode. |
Configuring a BulkStat Data Group
The Bulkstat data group element is used to group the data set, filter set, and instance set and also to specify the processing options.
Perform this task to configure the Bulkstat data group.
1.
enable
2.
configure
terminal
3.
bulkstat
data-group
data-group-name
4.
collect type {command
|
snmp} {{data
data-set-name
filter
filter-set-name} |
instance
instance-set-name}
5.
context
context-name
6.
interval
polling
polling-interval
7.
discard
8.
process
9.
end
DETAILED STEPS
Command or Action | Purpose | |||
---|---|---|---|---|
Step 1 |
enable
Example: Device> enable |
Enables privileged EXEC mode. | ||
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. | ||
Step 3 |
bulkstat
data-group
data-group-name
Example: Device(config)# bulkstat data-group if-dg |
Defines a Bulkstat data group and enters Bulkstat data group configuration mode.
| ||
Step 4 | collect type {command
|
snmp} {{data
data-set-name
filter
filter-set-name} |
instance
instance-set-name}
Example: The following example shows how to configure the Bulkstat to collect the output of the show snmp command with filter set. Device(config-bs-dg)# collect type command data show-snmp filter Ethernet Example: The following example shows how to configure the Bulkstat to collect SNMP objects. Device(config-bs-dg)# collect type snmp data interface-stats instance ins-exact filter ifType Example: Device(config-bs-dg)# collect type snmp data User-Stats
| |||
Step 5 | context
context-name
Example: Device(config-bs-dg)# context ctx-name |
Specifies the management context from which to obtain data for this data group. | ||
Step 6 | interval
polling
polling-interval
Example: Device(config-bs-dg)# interval polling 100 |
Specifies the collection periodic interval in seconds. In case of recurring collection, the data is collected at the expiration of the collection interval until the collection is stopped. | ||
Step 7 | discard
Example: Device(config-bs-dg)# discard |
Specifies whether to discard the raw data. | ||
Step 8 | process
Example: Device(config-bs-dg)# process |
Configures process-related parameters for a data group. | ||
Step 9 | end
Example: Device(config-bs-dg)# end |
Exits Bulkstat data group configuration mode and returns to privileged EXEC mode. |
Configuring a Bulkstat Profile
The profile element is used to group multiple data groups. This grouping simplifies the configuration and aggregates data of a similar nature. If two sets of data need to be written to the same file, the respective data groups should be linked as part of a single profile.
Perform this task to configure the Bulkstat profile:
1.
enable
2.
configure
terminal
3.
bulkstat
profile
profile-name
4.
data-group
{
data-group-name
|
pre-defined-data-group-name
[interval polling
{seconds}]}
5.
interval
transfer
{process
| raw
}{seconds}}
6.
file
format
schemaASCII
7.
file
retain
{disk
url
|
memory
seconds}
8.
file
size
bytes
9.
file
transfer
{retry
number
|
url
{primary
url
|
secondary
url
}}
10.
enable
11.
end
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | enable
Example: Device > enable |
Enables privileged EXEC mode. |
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. |
Step 3 |
bulkstat
profile
profile-name
Example: Device(config)# bulkstat profile if-stats |
Creates a profile with the given name and enters Bulkstat profile configuration mode. If the profile is already created, this command sets the context for the existing profile. |
Step 4 | data-group
{
data-group-name
|
pre-defined-data-group-name
[interval polling
{seconds}]}
Example: Device(config-bs-profile)# data-group if-dg |
Specifies the data group to be linked to this profile. Multiple data groups can be linked to a single profile. Interval polling of pre-defined data-groups can be configured at the profile level, and this will modify interval polling of the actual pre-defined data-group. |
Step 5 | interval
transfer
{process
| raw
}{seconds}}
Example: Device(config-bs-profile)# interval transfer raw 100 Example: Device(config-bs-profile)# interval transfer process 4000 |
Specifies the transfer periodic interval in seconds. In case of recurring transfer, the data is transferred at the expiration of the transfer interval until the transfer is stopped. |
Step 6 | file
format
schemaASCII
Example: Device(config-bs-profile)# file format schemaASCII |
Configures the file-related parameter for a profile. |
Step 7 | file
retain
{disk
url
|
memory
seconds}
Example: Device(config-bs-profile)# file retain memory 2000 |
Configures the file-related parameter retainfor a profile. |
Step 8 | file
size
bytes
Example: Device(config-bs-profile)# file size 2048 |
Configures the file-related parameter for a profile. |
Step 9 | file
transfer
{retry
number
|
url
{primary
url
|
secondary
url
}}
Example: Device(config-bs-profile)# file transfer url primary tftp://10.0.0.1/dcm/cpu-stats |
Configures the file related parameter transfer for a profile. |
Step 10 | enable
Example: Device(config-bs-profile)# enable |
Enables the profile for collection and transfer. |
Step 11 | end
Example: Device(config-bs-profile)# end |
Exits Bulkstat data profile configuration mode and returns to privileged EXEC mode. |
Configuring Bulkstat Calendar Scheduling
Perform this task to configure Bulkstat calendar scheduling.
1.
enable
2.
configure
terminal
3.
bulkstat
schedule
schedule-name
at
time-of-day {date |
week |
month date {oneshot |
recurring} |
oneshot |
recurring}
4.
profile profile-name
start
{oneshot
| recurring
number}
5.
profile profile-name
stop
6.
end
DETAILED STEPS
Command or Action | Purpose | |||
---|---|---|---|---|
Step 1 |
enable
Example: Device > enable |
Enables privileged EXEC mode. | ||
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. | ||
Step 3 |
bulkstat
schedule
schedule-name
at
time-of-day {date |
week |
month date {oneshot |
recurring} |
oneshot |
recurring}
Example: Device(config)# bulkstat schedule mycal at 18:30 feb 05 oneshot |
Defines the Bulkstat calendar scheduler set and enters Bulkstat event scheduler configuration mode.
| ||
Step 4 |
profile profile-name
start
{oneshot
| recurring
number}
Example: R1(config-bs-schedule)# profile cpu-process start recurring 5 |
Creates a profile and sets the condition to enable the profile for a one-time event or enables the profile for multiple events. | ||
Step 5 |
profile profile-name
stop
Example: R1(config-bs-schedule)# profile cpu-process stop |
Disables the profile. | ||
Step 6 |
end
Example: Device(config-bs-schedule)# end |
Exits Bulkstat event scheduler configuration mode and returns to privileged EXEC mode. |
Configuring a Bulkstat Resource Limit
Perform this task to configure memory resource limit in percentage of the total available memory.
1.
enable
2.
configure
terminal
3.
bulkstat resource
limit
memory memory-usage-percentage
4.
end
DETAILED STEPS
Command or Action | Purpose | |||
---|---|---|---|---|
Step 1 |
enable
Example: Device> enable |
Enables privileged EXEC mode. | ||
Step 2 |
configure
terminal
Example: Device# configure terminal |
Enters global configuration mode. | ||
Step 3 |
bulkstat resource
limit
memory memory-usage-percentage
Example: Device(config)# bulkstat resource limit memory 45 |
Defines the memory resource limit.
| ||
Step 4 | end
Example: Device(config)# end | Exits global configuration mode and returns to privileged EXEC mode. |
Configuration Examples for Cisco Data Collection Manager
Example: Collecting Sorted CPU Processes
The following is sample output that shows the configuration tasks that you need to perform to collect data about the processes in the cpu in the device, such as a router or a switch in a sorted order. The polling interval is set for 300 seconds, while the interval at which the raw data is transferred is set at 1500 seconds.
Device> enable Device# configure terminal Device(config)# bulkstat data show-cpu type command Device(config-bs-ds-cmd)# add cmd show processes cpu sorted Device(config-bs-ds-cmd)# exit Device(config)# bulkstat data-group show-cpu Device(config-bs-dg)# collect type command data show-cpu Device(config-bs-dg)# interval polling 300 Device(config-bs-dg)# process Device(config-bs-dg-proc)# exit Device(config-bs-dg)# exit Device(config)# bulkstat profile show-cpu Device(config-bs-profile)# data-group show-cpu Device(config-bs-profile)# interval transfer raw 1500 Device(config-bs-profile)# enable Device(config-bs-profile)# end Device#
Example: Collecting SNMP Interface Statistics
The following shows the configuration steps that you need to perform to collect SNMP interface statistics for the specified interface, Ethernet. The polling interval is set at 30 seconds, while the interval at which the raw data is transferred is set at 60 seconds.
Device> enable Device# configure terminal Device(config)# bulkstat data if-mib type snmp Device(config-bs-ds-snmp)# object ifDescr Device(config-bs-ds-snmp)# object ifInOctets Device(config-bs-ds-snmp)# object ifOutOctets Device(config-bs-ds-snmp)# exit Device(config)# bulkstat instance if-mib type snmp Device(config-bs-is-snmp)# wildcard Device(config-bs-ds-snmp)# exit Device(config)# bulkstat filter if-mib Device(config-bs-fs)# match ifDescr start "Ethernet" Device(config-bs-fs)# exit Device(config)# bulkstat data-group if-group Device(config-bs-dg)# interval polling 30 Device(config-bs-dg)# collect type snmp data if-mib instance if-mib filter if-mib Device(config-bs-dg)# exit Device(config)# bulkstat profile snmp_profile Device(config-bs-profile)# file transfer url primary tftp://10.64.68.12/dcm_data/ Device(config-bs-profile)# interval transfer raw 60 Device(config-bs-profile)# data-group if-group Device(config-bs-profile)# enable Device(config-bs-profile)# end Device#
Example: Configuring the Processing Show Commands Output
The following shows the configuration steps that you need to perform and to display the result of the show data-group command:
Device> enable Device# configure terminal Device(config)# bulkstat data ds1 type snmp Device(config-bs-ds-snmp)# object 1.3.6.1.2.1.2.2.1.16 alias ifOutOctets Device(config-bs-ds-snmp)# object 1.3.6.1.2.1.2.2.1.10 alias ifInOctets Device(config-bs-ds-snmp)# exit Device(config)# bulkstat instance is1 type snmp Device(config-bs-is-snmp)# wildcard Device(config-bs-ds-snmp)# exit Device(config)# bulkstat data-group dg1 Device(config-bs-dg)# collect type snmp data ds1 instance is1 Device(config-bs-dg)# interval polling 15 Device(config-bs-dg)# process Device(config-bs-dg-proc)# enable percentile Device(config-bs-dg-proc)# object 1.3.6.1.2.1.2.2.1.16 sample absolute Device(config-bs-dg-proc-obj)# buckets 250 Device(config-bs-dg-proc-obj)# exit Device(config-bs-dg-proc)# exit Device(config-bs-dg)# exit Device(config)# bulkstat profile profile1 Device(config-bs-profile)# data-group dg1 Device(config-bs-profile)# interval transfer process 1800 Device(config-bs-profile)# file size 1024000 Device(config-bs-profile)# enable Device(config-bs-profile)# end Device# show bulkstat data-group dg1 process summary Data-Group dg1 Process data Objectname : 1.3.6.1.2.1.2.2.1.16 Number of samples: 4 Summary Data : Instance Min Max Sum Average -------------------------------------------------------- 436752384 11376 11376 45504 11376.000 436867072 11376 11376 45504 11376.000 436871168 11376 11376 45504 11376.000 436887552 11376 11376 45504 11376.000 436809728 11376 11376 45504 11376.000 436830208 11376 11376 45504 11376.000 436920320 11376 11376 45504 11376.000 436891648 11376 11376 45504 11376.000 436793344 11376 11376 45504 11376.000 436899840 11376 11376 45504 11376.000 436817920 11376 11376 45504 11376.000 436768768 11376 11376 45504 11376.000 436785152 11376 11376 45504 11376.000 436772864 11376 11376 45504 11376.000 436736000 11376 11376 45504 11376.000 436731904 11376 11376 45504 11376.000 436838400 11376 11376 45504 11376.000 436858880 11376 11376 45504 11376.000 436756480 11376 11376 45504 11376.000 436740096 11376 11376 45504 11376.000 436776960 11376 11376 45504 11376.000 436834304 11376 11376 45504 11376.000 436875264 11376 11376 45504 11376.000 436924416 11376 11376 45504 11376.000 Device# show bulkstat data-group dg1 process distribution Data-Group dg1 Process data Objectname : 1.3.6.1.2.1.2.2.1.16 Number of samples: 9 Distribution Data: * Buckets with no data are not shown Instance Number of Range Range buckets start end ------------------------------------------------------- 436752384 250 0 4294967295 Bucket Bucket Bucket Count Index Start End ------------------------------------------------------ 1 0.000 17179869.180 9 Instance Number of Range Range buckets start end ------------------------------------------------------- 436867072 250 0 4294967295 Bucket Bucket Bucket Count Index Start End ------------------------------------------------------ 1 0.000 17179869.180 9 Device# show bulkstat data-group dg1 process percentile Data-Group dg1 Process data Objectname : 1.3.6.1.2.1.2.2.1.16 Number of samples: 11 Percentile Data: Instance : 436752384 Percentile Values: P[000.000] = 11376.000 P[000.130] = 11376.000 P[002.280] = 11376.000 P[015.870] = 11376.000 P[050.000] = 11376.000 P[084.130] = 11376.000 P[097.720] = 11376.000 P[099.870] = 11376.000 P[100.000] = 11376.000 Instance : 436867072 Percentile Values: P[000.000] = 11376.000 P[000.130] = 11376.000 P[002.280] = 11376.000 P[015.870] = 11376.000 P[050.000] = 11376.000 P[084.130] = 11376.000 P[097.720] = 11376.000 P[099.870] = 11376.000 P[100.000] = 11376.000 Instance : 436871168 Percentile Values: P[000.000] = 11376.000 P[000.130] = 11376.000 P[002.280] = 11376.000 P[015.870] = 11376.000 P[050.000] = 11376.000 P[084.130] = 11376.000 P[097.720] = 11376.000 P[099.870] = 11376.000 P[100.000] = 11376.000
Additional References for Cisco Data Collection Manager
Related Documents
Related Topic |
Document Title |
---|---|
Cisco IOS commands |
|
BSDCM commands: Complete command syntax, command mode, command history, defaults, usage guidelines, and examples |
|
Periodic MIB data collection and transfer mechanism |
SNMP Configuration Guide |
Standards and RFCs
Standard/RFC |
Title |
---|---|
IETF Standard |
Exporting MIB Variables using the IPFIX Protocol |
RFC 2982 |
Distributed Management Expression MIB |
MIBs
MIB |
MIBs Link |
---|---|
To locate and download MIBs for selected platforms, Cisco software releases, and feature sets, use Cisco MIB Locator found at the following URL: http://www.cisco.com/go/mibs |
Technical Assistance
Description |
Link |
---|---|
The Cisco Support and Documentation website provides online resources to download documentation, software, and tools. Use these resources to install and configure the software and to troubleshoot and resolve technical issues with Cisco products and technologies. Access to most tools on the Cisco Support and Documentation website requires a Cisco.com user ID and password. |
Feature Information for Cisco Data Collection Manager
The following table provides release information about the feature or features described in this module. This table lists only the software release that introduced support for a given feature in a given software release train. Unless noted otherwise, subsequent releases of that software release train also support that feature.
Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to www.cisco.com/go/cfn. An account on Cisco.com is not required.
Feature Name |
Releases |
Feature Information |
---|---|---|
Cisco Data Collection Manager |
DCM 2.0 provides users an option to collect management data from various sources (SNMP, CLI), optionally process the data (max, min, avg, and percentile), and export the collected/processed/summarized data in multiple export formats (ASCII file, IPFIX stream, and so on). DCM 2.0 replaces the traditional PULL (polling) model with a PUSH model for collection of management information. |
Glossary
DATA GROUP—A collection of data set, instance set, filter set, and process set.
DATA SET—A collection of data-related configurations. A data set can be of multiple types: SNMP, command, and expression.
FILTER SET—A collection of filter-related configurations.
INSTANCE SET—A collection of instance-related configurations for SNMP.
PROCESS SET—A collection of data-processing-related configurations.
PROFILE—A collection of data group, transfer, and storage.
STORAGE—A collection of storage-related configurations.
TRANSFER—A collection of transfer-related configurations.