LEDs

Switch Chassis LEDs

The BCN, STS, and ENV, LEDs are located on the left side of the front of the switch. The port LEDs appear as triangles pointing up or down to the nearest port.

LED

Color

Status

BCN

Flashing blue

The operator has activated this LED to identify this switch in the chassis.

Off

This switch is not being identified.

STS

Green

The switch is operational.

Flashing amber

The switch is booting up.

Amber

Temperature exceeds the minor alarm threshold.

Red

Temperature exceeds the major alarm threshold.

Off

The switch is not receiving power.

ENV

Green

Fans and power supply modules are operational.

Amber

At least one fan or power supply module is not operating.

(port)

Green

Port admin state is 'Enabled', SFP is present and the interface is connected (that is, cabled, and the link is up).

Amber

Port admin state is 'Disabled, or the SFP is absent, or both.

Off

Port admin state is 'Enabled' and SFP is present, but interface is not connected.

Fan Module LEDs

The fan module status LED is located below the air holes on the front of the module.

LED Color Status

Status

Green

The fan module is operational.

Red

The fan module is not operational (fan is probably not functional).

Off

Fan module is not receiving power.

Power Supply LEDs

The power supply LEDs are located on the lower right portion of the power supply. LEDs indicate the status for the module as shown in the following table.

LED

Status

Green

Power supply is on and outputting power to the switch.

Flashing green

Power supply is connected to an AC power source but not outputting power to the switch. The power supply may not be properly installed in the chassis.

off

Either all the installed power supplies are not receiving power or an uninstalled power supply is not receiving power.

Flashing amber

Power supply is operating but a warning condition has occurred—possibly one of the following conditions:

  • High temperature

  • High power

  • Slow power supply fan

  • Low voltage

  • Power supply is installed in the chassis but was disconnected from the power source.

Off

Power supply is installed without a connection to a power source.

Amber

Power supply failure—possibly one of the following conditions:

  • Over voltage

  • Over current

  • Over temperature

  • Power supply fan failure.