PDF(265.9 KB) View with Adobe Reader on a variety of devices
ePub(82.1 KB) View in various apps on iPhone, iPad, Android, Sony Reader, or Windows Phone
Mobi (Kindle)(83.1 KB) View on Kindle device or Kindle app on multiple devices
Updated:July 17, 2015
Bias-Free Language
The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
Release Notes for SPA100 Series Analog Telephone Adapters Firmware Version 1.3.5(XU)
Firmware Released: September 2014
Document Revised: July 2015
These Release Notes provide information about SPA100 Series Analog Telephone Adapters firmware version 1.3.5(XU).
IMPORTANT
As with any firmware release, read these release notes before upgrading the firmware. Cisco also recommends backing up the configuration before any firmware upgrade.
Changes in Firmware Version 1.3.5(XU) from 1.3.2(XU)
Improvement in reboot time for SPA122, to increase in RC provisioning speed.
User is able to add configurable prefix to syslog. For example: $PN, $MA, etc.
Support SIP Notify event. When the parameter <Provisioning Enable> is set to “no”, SPA can resync to turn on provisioning remotely. Note: This feature applies only to RC unit.
Support logs over TLS.
Support SSL email.
Enhancement to include device MAC address in syslog messages.
Report low memory availability via syslog, and show memory usage on the web page.
Support firmware upgrade using HTTP 302 redirection.
Caller ID can be updated while creating a conference.
Support Call Hold reminder when the caller makes the second call while the first call is on hold.
Open Secure Sockets Layer (SSL) open source library used in the ATA is upgraded to 1.0.1g in order to support TLS 1.2.
LED pattern is added specifically for RC status in SPA122-RC to allow users to view and monitor the RC process.
The SIP parameter “Hook Flash MIME Type” is set to application/broadsoft, so that the Metaswitch server recognizes the flashhook event.
Add a new parameter “Feature Key Sync” for FXS. The default value is no. This parameter enables synchronization of DND and CFWD (forward all, forward busy, and forward no answer) settings between ATA and the proxy server. Any change in the fields on the ATA is notified to the proxy and vice versa.
Support “Conference Bridge URL”. The default setting is blank. After setting it to a valid URL, the user can establish a 3-way conference by hookflash of FXS port. For n>3, user can add participants by making new calls.
Hardware and Firmware Compatibility Matrix
SPA112/SPA122
(3 types of devices)
SN Range
1.3.5p(XU), 1.3.5p, 1.3.2p
1.3.5(XU), 1.3.5, 1.3.4, 1.3.3, 1.3.2n
1.3.2(XU), 1.3.2 or earlier
Device 1
(128MB Flash + New Si3217x-B SLIC)
SPA112
CCQ18400001 to CCQ1841033K
After CCQ18500DAE
SPA122
CCQ1834031U to CCQ1834037D
CCQ1847066I to CCQ184707YA
CCQ184902ED to CCQ184904UL
CCQ184904UM to CCQ184904Y3
CCQ184904Y4 to CCQ184904Y5
After CCQ185001YH
Yes
No
No
Device 2
(128MB Flash + Old Si3217x-B SLIC)
SPA112
CCQ175106J3 to CCQ175106OM
CCQ181607OO to CCQ181607U7
CCQ18240E34 to CCQ18400000
CCQ1841033L to CCQ18500D9K
SPA122
CCQ174602V3 to CCQ1746030M
CCQ181502B7 to CCQ181502GQ
CCQ182002W3 to CCQ1834031T
CCQ1834037E to CCQ18470660
CCQ184707YB to CCQ184902EC
CCQ184904UM to CCQ184904UL
CCQ184904Y4 to CCQ184904Y3
CCQ184904Y6 to CCQ185001YH
Yes
Yes
No
Device 3
(32MB Flash + Old Si3217x-B SLIC)
SPA112: Before CCQ182002W2
SPA122: Before CCQ181805KR
Yes
Yes
Yes
Note Do not upgrade any device to an unsupported firmware version as detailed in the Hardware and Firmware Compatibility Matrix table.
Note 1.3.2p is identical to 1.3.2 and additionally supports 128MB flash and new SLIC. 1.3.2n is based on 1.3.2; both have the same feature set, except that 1.3.2n supports 128MB flash while 1.3.2 does not. 1.3.5p is based on 1.3.5; both have the same feature set, except that 1.3.5p supports new SLIC while 1.3.5 does not. 1.3.5p(XU), 1.3.5(XU), 1.3.2(XU): SRTP functionality has been removed, and it cannot be configured or provisioned in firmware versions that are designated with XU in the filename.
Note New devices have a label that reads S/W: Must use 1.3.5(004p) or later.
Resolved Issues
Identifier
Headline
CSCuf02996
Resync error retry delay is applicable even after profile rule is modified.
CSCue99038
Reset button factory reset is not always effective.
CSCue99016
Web Access Admin Access is disabled from web-GUI but not from config.
CSCuo85817
DNS retry optimization for RC provisioning.
CSCup79722
The default value of LLDP is different from the configuration generated by the SPC tool.
CSCuq14803
SPA112: Admin access not available in the configuration file generated by the SPC tool.
CSCtz07722
SRP references in the administration guide changed to SPA100.
CSCtz15389
Blind Transfer: When a complete number is entered, the ATA sends a SIP INVITE message with the Refer-To target equals to *98 target_number.
CSCud44154
SPA122 fails to load the first profile rule when both the profile rules are changed.
CSCuh26401
SPA112: IVR option 170 does not work properly.
CSCuo42957
SPA112: PSTN Caller ID is not displayed on the phone connected to SPA112/SPA122.
CSCuo44768
IVR Menu Options 1911 and 1921 are not valid anymore.
CSCuo49341
SPA122-RC: Power LED Indicator on RC devices to check the status of RC provisioning process.
CSCuo77458
SPA122-RC: DNS retry missed the first value in the Resync Error Retry Delay.
CSCuo85834
Monitor and document the SPA122-RC Provisioning Time Optimization. (Reduce the RC provisioning time by at least 2 minutes. NOTE: The complete RC device provisioning time should be between 5 - 7 minutes.)
CSCuo44802
Obsolete Link for Music Coupler needs to be updated.
CSCuq87602
SPA1xx&SPA232D: Some parameters for supplementary Service do not work.
CSCuj33644
SPA1xx: version-style conditional expression broken on XU image.
Known Issues
Identifier
Headline
CSCul21696
T38 fax fails with model “Cannon MX850,” but successful with other models like Brother FAX 8360P, Xerox WorkCentre Pro 575, Panasonic UF-9000, and HP Officejet 7110.
CSCtq39251
The volume is 2dbm lower than the SPA2102 with default settings.
CSCuf54553
FQDN is required in the profile rule after setting Restricted Access Domains.
CSCul61825
The SPA100/200 series does not support RFC2543 Call Hold. (NOTE: Re-INVITE message always has the device ip address in its SDP and not 0.0.0.0.)
CSCuq06381
SPA122-RC: To get the new configuration on RC, power cycle is needed after custom reset.
CSCuq17200
SPA112&122: The minor version number in brackets () is ignored while upgrading using “Upgrade Rule.”
CSCuq21428
SPA112: Cannot change Web Utility Access and Remote Management Port via resync.
Note 1: Firmware Downgrade Limitation
The devices with the following PID and TAN (or later TAN number) cannot be downgraded to a version older than 1.3.3.
PID
TAN
SPA112-BR
74-11115-01 G0
SPA122-BR
74-11116-01 F0
SPA112
74-9317-02 G0
SPA122
74-9318-02 G0
SPA122-RC
74-9319-02 G0
Note 2: 2K Certificate
Server Certification
If the device is upgraded to 1.3.3 or later (no hardware related), the server could request a server certification signed by the “Cisco 2k Small Business CA” or keep using certificate signed by 1k CA. Be careful, it is optional because the new singed 2k server certificate is not compatible with old firmware (before 1.3.3). While the server certificates signed by 1k CA are working for all firmware, before and after 1.3.3.
Client Certification
SPA112&122&232D with SN CCQ18230001 and after have a built-in 2k Client Certificate. Then server must update the new Combined CA if the client certification is required. The new Combined CA is compatible with the old 1k & 2k certificate, that means it works for all the devices.
Upgrade the Firmware
Follow these instructions to upgrade the phone adapter.
Step 2 Launch a web browser, and enter the LAN IP addresses of the phone adapter.
Step 3 Log in to the Configuration Utility.
Step 4 Click Administration in the menu bar, and then click Firmware Upgrade in the navigation tree.
Step 5 Click Browse and select the location of the upgrade file that you downloaded.
Step 6 Click the Upgrade button to upgrade the firmware.
Note Upgrading the firmware may take several minutes. Until the process is complete, DO NOT turn off the power, press the hardware reset button, or click the Back button in your current browser.
Behavior During Times of Network Congestion
Anything that degrades network performance can affect voice and video quality, and in some cases, can cause a call to drop. Sources of network degradation can include, but are not limited to, the following activities:
Administrative tasks, such as an internal port scan or security scan
Attacks that occur on your network, such as a Denial of Service attack
To reduce or eliminate any adverse effects to the devices, schedule administrative network tasks during a time when the devices are not being used or exclude the devices from testing.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)