The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This document describes the features, issues, and exceptions of Cisco NX-OS Release 9.3(7) software for use on Cisco Nexus 9000 Series switches.
Note: The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product.
The following table lists the changes to this document.
Table 1. Changes to this Document
Date |
Description |
April 25, 2024 |
Added CSCwh50989 and CSCwe53655 to Open Issues. |
July 18, 2023 |
Added flex link to the Enhanced Features section. |
October 5, 2021 |
Added details about Thousand Eyes (TE) Integration feature in the New and Enhanced Software Features section. |
March 11, 2021 |
Cisco NX-OS Release 9.3(7) became available. |
New and Enhanced Software Features
New Features |
|
Feature |
Description |
RPC to get generate diff between candidate and running datastores |
Introduced Cisco NETCONF RPC - get_diff that enables a NETCONF server to return the difference between configuration databases. This new option instructs the switch to calculate on-box configuration difference in candidate or running datastore.
For more information, see the Cisco Nexus 9000 Series NX-OS Programmability Guide, Release 9.3(x). |
Thousand Eyes (TE) Integration |
Introduced Thousand eyes integration support with Cisco Nexus 9000 Series switches. For product overview look at:
It is a must to install the following general SMU when TE integration is performed:
nxos.CSCvz52812-n9k_ALL-1.0.0-9.3.7.lib32_n9000.tar
For SMU installation please refer to the following guide:
|
The enhanced features listed below are existing features introduced in earlier releases but enhanced with new support in Cisco NX-OS Release 9.3(7).
Enhanced Features |
|
Feature |
Description |
SNMPv3 encryption with SHA256 |
Introduced HMAC-SHA-256 authentication protocol support for SNMPv3.
For more information, see the Cisco Nexus 9000 Series NX-OS System Management Configuration Guide, Release 9.3(x) . |
MACsec with QSA |
Added MACsec support when QSA is enabled in Cisco Nexus N9K-C9364C and N9K-C9336C-FX2 platform switches.
Cisco Nexus N9k-C9364C and N9K-C9336C-FX2 supports MACSEC with QSA and 10G link combination from Cisco NX-OS Releasee 9.3(7).
For more information, see the Cisco Nexus 9000 Series Security Configuration Guide, Release 9.3(x). |
Flex Link |
Added support for flex link on Cisco N9K-C93180YC-FX3 platform switch.
For more information, see Cisco Nexus 9000 Series NX-OS Layer 2 Switching Configuration Guide, Release 9.3(x). |
FEX |
Added support for FEX on Cisco Nexus 93180YC-FX3S platform switch. This switch can be used in either FEX mode or TOR mode. For more information on converting the switch from one mode to another. Note: The Cisco Nexus 93180YC-FX3S switch in software FEX mode supports 25-G FEX connectivity to the host for single-point-of-management. For more information, see the Cisco Nexus 2000 Series NX-OS Fabric Extender Configuration Guide for Cisco Nexus 9000 Series Switches, Release 9.3(x). |
The following new hardware are introduced in Cisco NX-OS Release 9.3(7):
● NXA-SFAN-65CFM-PI Fan for N9K-C9336C-FX2
● NXA-SFAN-65CFM-PE Fan for N9K-C9336C-FX2
Note: To enable or disable displaying the serial number of the NXA-SFAN-65CFM-PI or NXA-SFAN-65CFM-PE fan, enter the hardware fan-sprom command.
Bug ID |
Description |
Headline: Unsupported TCAM region config added when ISSU from 9.2.4 to 9.3.4
Symptoms: Following lines exist in running-config and cannot be removed: hardware access-list tcam region ing-racl-lite 534756472 double-widehardware access-list tcam region ing-short 189402400 double-widehardware access-list tcam region ing-ifacl-ipv4-lite 1hardware access-list tcam region ing-ifacl-ipv6-lite 32784hardware access-list tcam region ing-cntacl 1hardware access-list tcam region ing-mvpn 370590546 double-widehardware access-list tcam region ing-l2-l3-qos 28hardware access-list tcam region hw-telemetry 1
Workaround: Perform write-erase followed by reload. |
|
Headline: "no negotiate auto" is removed from RJ-45 member interface and not from PO
Symptoms: If a RJ-45 port is member of a port-channel, with "no negotiate auto" configuration on the port-channel and member interfaces, that configuration gets removed from the member interface, but not from the port-channel after ISSU from a pre-9.3(4) or pre-7.0(3)I7(8) image to later images.
"show running interface e<x/y>" would not have "no negotiate auto" config "show running interface po<>" would have "no negotiate auto" config "no channel-group <>" config on the member interface will not take effect
Workaround: - Remove "no negotiate auto" config from port-channel interface with RJ45 ports
Workaround for Post-ISSU (if the pre-ISSU workaround is not applied): - Remove "no negotiate auto" config from port-channel interface with RJ45 ports - Run "channel-group " config on all members again |
|
Headline: 1G GLC-TE port was not coming up on N9K-C93360YC-FX2 after unplug and replug the SFP
Symptoms: Connect C2960X to Nexus 9000 with GLC-TE. Keep the connection up first and then unplug and replug the SFP on Nexus 9000 side. The port will not come up untill you shut /no shut the port on Nexus 9000 side.
Workaround: Shut /no shut the port on Nexus 9000 side. |
|
Headline: SNMP Crash in Nexus 9000 after ISSU Upgrade
Symptoms: Nexus9000 C9504, supervisor "N9K-SUP-A" crashed in during no disruptive upgrade from 7.0(3)I4(7) to 7.0(3)I7(9) aborting the ISSU.
Workaround: None |
|
Headline: Installing multiple SMUs do not remain committed after reload.
Symptoms: When installing multiple SMUs they do not remain committed after reload.
Workaround: Upgrade to a version that contains the fixes natively. |
|
Headline: Nexus 9000 aclqos cores - ERSPAN w/source VLAN mapped to VNI on certain ports
Symptoms: Gen1 Nexus 9000 models may see a core file from the aclqos process when trying to do an ERSPAN on a VLAN mapped to a VNI, using ports from speicifc ASICs.
Workaround: None |
|
Headline: Module ejector interrupt storm causing plfm mgr crash
Symptoms: Marginal seating of IO module can lead to ejector button driven interrupt storm which causes platform manager to crash.
Workaround: Reseat module to verify good connection, verify chassis grounding, etc. |
|
Headline: BGP flaps (with holdtimer expired) every time a new leaf is added or reloaded
Symptoms: VXLAN spine and leaf mode on infrastructure of Nexus 93180YC works fine without any problem. The issue arises when reloading leaf X or introducing a new leaf, this will make that a random leaf of the network connected to same spines loses BGP connection. This happens randomly, affecting different leafs.The evpn architecture implemented is based on a bgp ipv4 underlay, making it possible to announce the loopbacks of the Nexus serving as termination for the VTEPs.
Workaround: None |
|
Headline: HW Multipath table is not programming some links.
Symptoms: Available paths seen on show ip route for equal cost paths are not being fully utilized.
Workaround: Bundle uplinks in L3 port-channel |
|
Headline: MAC Mobility Seq is not updated correctly upon MAC moves
Symptoms: MAC Mobility sequence number is not correctly updated on EVPN routes when a host moves from one site to another.Missing the correct Sequence number might lead BGP to select non-optimum paths.
Workaround: None |
|
Headline: Bringing up SPAN session silently fails when sFlow data sources are configured
Symptom: A Nexus 9000 series switch configured with sFlow data sources is not able to administratively bring SPAN sessions online. This is expected behavior and is a documented limitation. If at least one sFlow data source is configured, the SPAN sessions cannot be brought up. However, no error message or feedback is presented if one attempts to bring a SPAN session up while an sFlow data source is configured.
Workaround: There is no known workaround for this issue. This defect introduces an error message to the CLI of the switch when one attempts to bring a SPAN session up while sFlow data sources are configured on the switch. |
|
Headline: SPAN session administrative status becomes stuck when brought up alongside sFlow data sources
Symptom: A Nexus 9000 series switch configured with sFlow data sources is not able to administratively bring SPAN sessions online. This is expected behavior and is a documented limitation. If at least one sFlow data source is configured, the SPAN sessions cannot be brought up. However, if one removes all sFlow data sources from the switch's configuration and attempts to administratively bring the SPAN session up, the SPAN session will remain in a down state.
Workaround: Administratively shutting down the SPAN session (even though it's technically already administratively shut down), then attempt to bring it back up. |
|
Headline: `udld disable` on breakout interfaces is removed from running configuration after upgrade
Symptom: UDLD operational on a 4x10G interface that was previously configured to have udld disabled.
Workaround:None |
|
Headline: CFS HAP reset and core file during system switchover
Symptom: A Nexus 9500 switch on 7.0(3)I7(x) version may undergo a HAP reset and generate a core file on performing a system switchover.
Workaround: None |
|
Headline: Nexus9300 unexpect options ( port 1 216 ) are set on show run all
Symptom: When configuring "hardware rate-limiter access-list-log XXX" the port 1 216 are set on show run all like below.
---hardware rate-limiter layer-3 glean 100 module 1 port 1 216hardware rate-limiter layer-3 multicast local-groups 3000 module 1 port 1 216hardware rate-limiter access-list-log 100 module 1 port 1 216hardware rate-limiter bfd 10000 module 1 port 1 216hardware rate-limiter fex 12000 module 1 port 1 216hardware rate-limiter span 50 module 1 port 1 216hardware rate-limiter sflow 40000 module 1 port 1 216hardware rate-limiter vxlan-oam 1000 module 1 port 1 216hardware rate-limiter 100M-Ethports 10000 module 1 port 1 216hardware rate-limiter DOT1X 3000 module 1 port 1 216hardware rate-limiter mpls-oam 300 module 1 port 1 216hardware rate-limiter netflow 120000 module 1 port 1 216---But it is not possible to even configure "... port 1 216" on the device.---switch# conf tEnter configuration commands, one per line. End with CNTL/Z.switch(config)# hardware rate-limiter layer-3 glean 100 module 1 port 1 216 ^% Invalid number, range is (1:48) at '^' marker.switch(config)# ---
Workaround: Write erase and then reload the device. |
|
Headline: BGP remote-as route-map will be delete after default afi
Symptom: The BGP neighbor remote-as route-map will be deleted after the default afi show running config neighbor 10.1.1.0/24 remote-as route-map CLI is run.
Workaround: This is not an issue. The route-map is actually in effect. |
|
Headline: Random link flaps on N9K-C93108TC-EX with QSFP-4x10G-AOC
Symptom: Random L1 link flaps on N9K-C93108TC-EX with QSFP-4x10G-AOC
Workaround:Disable/blacklist/admin-down all not-connected/unused breakout ports to reduce the frequency of link flap. |
|
Headline: N9k VXLAN - Non-Zero ESI value can result in blackholing.
Symptom: Example output:
N9K-VTEP# show mac address-table vlan 2431 | i beefC 2431 dead.beef.aaaa dynamic 0 F F nve1(192.168.50.10 192.168.50.11) <- - - MAC is associated with two NVE peers. N9K-VTEP# show l2route evpn mac evi 2431 mac dead.beef.aaaa detailFlags -(Rmac):Router MAC (Stt):Static (L):Local (R):Remote (V):vPC link(Dup):Duplicate (Spl):Split (Rcv):Recv (AD):Auto-Delete (D):Del Pending(S):Stale (C):Clear, (Ps):Peer Sync (O):Re-Originated (Nho):NH-Override(Pf):Permanently-Frozen, (Orp): OrphanTopology Mac Address Prod Flags Seq No Next-Hops----------- -------------- ------ ------------- ---------- ----------------2431 dead.beef.aaaa BGP Rcv 0 192.168.50.10 Route Resolution Type: ESI Forwarding State: Resolved (PL) Resultant PL: 192.168.50.10, 192.168.50.11 <- - - Two Resultant PL entries. Sent To: L2FM ESI : 03aa.aaaa.aaaa.aa00.0001 <- - - ESI is present. N9K-VTEP# show hardware mac address-table 1 vlan 2431 address dead.beef.aaaaFE | VLAN | MAC | Dynamic | Port |Location Index| | | | | | |---+------+---------------+---------+---------+--------------+0 2431 dead.beef.aaaa dynamic <- - - Egress port does not exist.Remove one of the remote VTEP and it works: N9K-VTEP# show l2route evpn mac evi 2431 mac dead.beef.aaaa detailFlags -(Rmac):Router MAC (Stt):Static (L):Local (R):Remote (V):vPC link(Dup):Duplicate (Spl):Split (Rcv):Recv (AD):Auto-Delete (D):Del Pending(S):Stale (C):Clear, (Ps):Peer Sync (O):Re-Originated (Nho):NH-Override(Pf):Permanently-Frozen, (Orp): OrphanTopology Mac Address Prod Flags Seq No Next-Hops----------- -------------- ------ ------------- ---------- ----------------2431 dead.beef.aaaa BGP Rcv 0 192.168.50.10 Route Resolution Type: ESI Forwarding State: Resolved (PL) Resultant PL: 192.168.50.10 <- - - One Resultant PL entries. Sent To: L2FM ESI : 03aa.aaaa.aaaa.aa00.0001 <- - - ESI is present. N9K-VTEP# show hardware mac address-table 1 vlan 2431 address dead.beef.aaaaFE | VLAN | MAC | Dynamic | Port |Location Index| | | | | | |---+------+---------------+---------+---------+--------------+0 2431 dead.beef.aaaa dynamic nve1 <- - - Egress port is now populated.
Workaround: Do not use ESI. ESI is not currently supported on Cloudscale platforms. For Nexus 9000 switches vPC can be used instead of ESI for dual homing and redundancy. |
|
Headline: Nexus 9500 EX/FX SVI unicast counters do not work
Symptom: Unicast SVI counters remain 0 in `show interface` and `show interface` and the `show vlan id X counters`.
Workaround: None |
|
Headline: SSH Connection Rejected with FIPS enabled using any ssh key
Symptom: SSH connections will be rejected if FIPS feature is enabled on version 9.3.7. This issue is similar to CSCvu10721 but ssh is also rejected for ecdsa key.
Workaround: Downgrade to version 9.3.6 or earlier, or upgrade to 10.1.1. Issue will be resolved in next NXOS release, 9.3.8.
|
|
Headline: l2fm process crash after l2fm_mcec_get_mac_handler
Symptom: l2fm process crashed after vPC came online:
%$ VDC-1 %$ %ASCII-CFG-2-CONF_CONTROL: System ready %$ VDC-1 %$ %VPC-2-PEER_KEEP_ALIVE_RECV_FAIL: In domain 100, VPC peer keep-alive receive has failed %$ VDC-1 %$ %VPC-2-PEER_KEEP_ALIVE_RECV_FAIL: In domain 100, VPC peer keep-alive receive has failed (message repeated 1 time) %$ VDC-1 %$ %VPC-2-PEER_KEEP_ALIVE_RECV_FAIL: In domain 100, VPC peer keep-alive receive has failed (message repeated 1 time) ... %$ VDC-1 %$ %SYSMGR-2-SERVICE_CRASHED: Service "l2fm" (PID 7824) hasn't caught signal 11 (core will be saved).
Workaround: Disconnect vPC peer link and upgrade both peers separately. |
|
Headline: Revert reserved MAC blocking behavior for VRRP macs on SVIs Symptoms: User is not able to configure VRRP VMAC on SVI interfaces. Workarounds: None. |
|
Headline: Custom COPP causing transit traffic to be punted to the CPU on Nexus 9300-GX2 Symptoms: When custom-COPP policy contains ACL rules which match on Layer 4 destination or source port, transit traffic also hits the COPP and the packets are copied to CPU. This causes duplication of traffic as CPU also routes the copied packets to the destination. Workarounds: Custom COPP policy using src/dst match mitigates punt for transit traffic. |
Bug ID |
Description |
Headline: Nexus 9000/3000 NXOS : Micron_M500IT Bootflash in read only mode Symptoms: Nexus 9000/3000 switch bootflash goes into read-only mode with Micron_M500IT SSD drive after 28,224 power-on-hours (POH) for the first time. The bootflash will stop responding causing failure of operations such as config changes/save, read/write operations etc. Workarounds: Reload the switch. However, this failure will reappear after 1008 hours of operation. |
|
Headline: Port-channel load-balancing for MPLS tagged traffic on L2 transit N9k FX/EX switches · Enable feature mpls segment-routing (without further label switching use). · MPLS SR and VPC features are mutually exclusive. So device must be no VPC enabled. |
|
Headline: msdp owned (s,g) mroute does not inherit pim oif from (*,g) Symptoms: Receivers are not getting multicast stream. MSDP owned (S,G) mroute sync'd by MSDP peer/RP/Catalyst to RP/Nexus, does not inherit OIF from (*,G). Issue is specific to few groups, some groups are working fine too. interface Ethernet x/y ip igmp static-oif multicast_group source multicast_sender_ip |
|
Headline: 100G FR: Transceiver not coming up between C93600CD-GX and Mellanox switch Symptoms: Mellanox side is using a breakout cable breaking out from 400G into 4x100G. From Mellanox side one leg is connected to another vendor switch (port is up), the other 100G connected to N9k is down. |
|
Headline: BFD is blocked over Unnumbered Interfaces |
|
Headline: Non-MPLS device does not perform 5-tuple hashing for MPLS packets passing through. (FX,EX) |
|
Headline: Need to add a cli to view SFP details on N9K Mgmt0 port |
|
Headline: no vpc domain 20 removes previously configure vpc domain 10 without any warning |
|
Headline: NFM process crashes leads to hap-reset |
|
Headline: Nexus 9000 "Fabric Port Class X Output Drop Packets" counter constantly incrementing |
|
Headline: SVI goes down as soon as access interfaces goes down and only flex link stays up |
|
Headline: N9k EX - Dhcp snooping binding not refresh |
|
Headline: NXOS rfc1583compatibility not consistent with IOS/XE implementation |
|
Headline: after changing VPC HIF ports to orphan, Flood traffic crossing MCT does not egress HIF |
|
Headline: VXLAN: MAC address learned on Fabric Layer3 interfaces |
|
Headline: N9K - NXAPI : %SAFE_STR CONSTRAINT: strncpy_s: slen is zero, error code=401 |
|
Headline: Nexus switch "ipfib" crash |
|
Headline: NX93180LC - GLC-TEs not working after upgrade to 9.3.5 (notconnected) on even ports only |
|
Headline: Observing PTP port flap which is connected to STU(GM) |
|
Headline: CAP_FEATURE_MULTIHOP_BFD capability is not getting removed from the system after disabling BFD |
|
Headline: Incorrect Forwarding on Hardware. VXLAN Flood & Learn. IPFIB process stuck and MTS queue build up. |
|
Headline: NXOS: VLAN Manager crashes with VLAN mapping configuration change |
|
Headline: N9k IPv6 Neighbor Discovery COPP looks at mac & ipv6 addr that it does not own |
|
Headline: Hairpin of L2 multicast NLB KA frames on the same interface it was received |
|
Headline: HSRP vmac is not cleared and remains as static entry after shutting down SVI. |
|
Headline: N9K-C9348GC link up delay after reloaded |
|
Headline: N9K-PAC-650W for N9k reporting Fail/Shut status |
|
Headline: EOR - default v6 route not correctly programmed in hw with template-service-provider |
|
Headline: segmentation fault on call home service turn on after enabling smart license |
|
Headline: 'vpc orphan-port suspend' configuration can't be removed on interfaces associated to vPC PO |
|
Headline: vPC BGW : multisite bgp-if is up for 30s after peer-link failure on vpc secondary |
|
Headline: Unknown Unicast brief report doesn't indicate L2 miss |
|
Headline: Nexus 9K - Unable To Boot NXOS Version 9.x From USB |
|
Headline: N9500:other end port of mgmt port with shutdown force is up |
|
Headline: Nexus N9K-X9536PQ T2-EOR-LC card crashing and causing bcm-crash core |
|
Headline: ip routing multicast holddown 0 does not propagate in running config |
|
Headline: Elysian_TOR: Wrong delivery order and incorrect Timestamp(T1) carried by Follow-up pkt |
|
Headline: High memory usage by "MRIB" process on 9.3(3) |
|
Headline: On N9K-C9332C - 100G macsec links stop forwarding traffic |
|
Headline: STOMP generated on heavenly when using 1G xcvr |
|
Headline: Nexus 9000 forwards ARP traffic received on suspended interface, causing Layer 2 loop |
|
Headline: ISIS routes are not removed from routing table when the interface goes down. |
|
Headline: src_mac is 00:00:00:00:00:00 afer PBR routing after rebooting of one Nexus in VPC pair |
|
Headline: N9k:-FX and Other Platforms - DHCP Binding lease will not refresh |
|
Headline: cosmetic: Next Hop v6 Filter does not work properly on the show ip route output. |
|
Headline: Vfc interface mode can't be set to E |
|
Headline: N9k: port-security does not effect on the VPC port-channel |
|
Headline: After upgrade 9.x N9k cannot be downgraded via install all |
|
Headline: Nexus 9000 floods ARP Request with unicast destination MAC to VLAN |
|
Headline: Incorrect NIV programming after changing from VPC HIF to orphan port |
|
Headline: segmentation fault for Tunnel Manager (TM) Daemon in CLI for Tunnel mgr process |
|
Headline: No negotiate auto command missing after upgrade to 7.0(3)I7(9) |
|
Headline: N9K - Some 'redistribute direct' prefixes not advertised to eBGP peer. |
|
Headline: Nexus 9K Linecard Memory Leak in /tmp/logs/l2mcast_lib.log |
|
Headline: ON portfast enabled interface STP goes through BLK-LRN-FWD convergence after VPC sec turns Op. Prim |
|
Headline: 'lcnd: Vxlan-InnerIp size xx is less than expected' is shown in syslog |
|
Headline: Unicast traffic punted to CPU due to HW ADJ pointing to global glean adj |
|
Headline: 9736C-FX imposing two FCS headers on RX frames after link flap |
Known Issues
Bug ID |
Description |
10G QSA link in PCS mode is not working even without Macsec configuration. |
|
On Cisco Nexus N2K-C2348TQ HIFs fail to utilize redundant Port-Channel links, to NIF, during link failover events. |
The following tables list the Cisco Nexus 9000 Series hardware that Cisco NX-OS Release 9.3(7) supports. For additional information about the supported hardware, see the Hardware Installation Guide for your Cisco Nexus 9000 Series device.
Table 1. Cisco Nexus 9500 Switches
Bug ID |
Description |
N9K-C9504 |
7.1-RU modular switch with slots for up to 4 line cards in addition to two supervisors, 2 system controllers, 3 to 6 fabric modules, 3 fan trays, and up to 4 power supplies. |
N9K-C9508 |
13-RU modular switch with slots for up to 8 line cards in addition to two supervisors, 2 system controllers, 3 to 6 fabric modules, 3 fan trays, and up to 8 power supplies. |
N9K-C9516 |
21-RU modular switch with slots for up to 16 line cards in addition to two supervisors, 2 system controllers, 3 to 6 fabric modules, 3 fan trays, and up to 10 power supplies. |
Table 2. Cisco Nexus 9500 Cloud Scale Line Cards
Product ID |
Description |
Maximum Quantity |
||
Cisco Nexus |
Cisco Nexus |
Cisco Nexus |
||
N9K-X97160YC-EX |
Cisco Nexus 9500 48-port 10/25-Gigabit Ethernet SFP28 and 4-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
16 |
N9K-X9732C-EX |
Cisco Nexus 9500 32-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
16 |
N9K-X9732C-FX |
Cisco Nexus 9500 32-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
16 |
N9K-X9736C-EX |
Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
16 |
N9K-X9736C-FX |
Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
16 |
N9K-X9788TC-FX |
Cisco Nexus 9500 48-port 1/10-G BASE-T Ethernet and 4-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
16 |
Table 3. Cisco Nexus 9500 R-Series Line Cards
Product ID |
Description |
Maximum Quantity |
|
Cisco Nexus 9504 |
Cisco Nexus9508 |
||
N9K-X9636C-R |
Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
N9K-X9636C-RX |
Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
N9K-X9636Q-R |
Cisco Nexus 9500 36-port 40 Gigabit Ethernet QSFP line card |
4 |
8 |
N9K-X96136YC-R |
Cisco Nexus 9500 16-port 1/10 Gigabit, 32-port 10/25 Gigabit, and 4-port 40/100 Gigabit Ethernet line card |
4 |
8 |
Table 4. Cisco Nexus 9500 Classic Line Cards
Product ID |
Description |
Maximum Quantity |
||
Cisco Nexus |
Cisco Nexus |
Cisco Nexus |
||
N9K-X9408C-CFP2 |
Line card with 8 100 Gigabit CFP2 ports |
4 |
8 |
16 |
N9K-X9432C-S |
Cisco Nexus 9500 32-port 40/100 Gigabit Ethernet QSFP28 line card |
4 |
8 |
N/A |
N9K-X9432PQ |
Cisco Nexus 9500 32-port 40 Gigabit Ethernet QSFP+ line card |
4 |
8 |
16 |
N9K-X9636PQ |
Cisco Nexus 9500 36-port 40 Gigabit Ethernet QSFP+ line card |
4 |
8 |
N/A |
N9K-X9464PX |
Cisco Nexus 9500 48 1/10-Gigabit SFP+ and 4-port 40-Gigabit Ethernet QSFP+ line card |
4 |
8 |
16 |
N9K-X9464TX |
Cisco Nexus 9500 48 port 1/10-Gigabit BASE-T Ethernet and 4-port 40-Gigabit Ethernet QSFP+ line card |
4 |
8 |
16 |
N9K-X9464TX2 |
Cisco Nexus 9500 48 port 1/10-Gigabit BASE-T Ethernet and 4-port 40-Gigabit Ethernet QSFP+ line card |
4 |
8 |
16 |
N9K-X9536PQ |
Cisco Nexus 9500 36-port 40 Gigabit Ethernet QSFP+ line card |
4 |
8 |
16 |
N9K-X9564PX |
Cisco Nexus 9500 48 1/10-Gigabit SFP+ and 4 port 40-Gigabit Ethernet QSFP+ line card |
4 |
8 |
16 |
N9K-X9564TX |
Cisco Nexus 9500 48 port 1/10-Gigabit BASE-T Ethernet and 4 port 40-Gigabit Ethernet QSFP+ line card |
4 |
8 |
16 |
Table 5. Cisco Nexus 9500 Cloud Scale Fabric Modules
Product ID |
Description |
Minimum |
Maximum |
Table 6. Cisco Nexus 9500 R-Series Fabric Modules
Product ID |
Description |
Minimum |
Maximum |
Table 7. Cisco Nexus 9500 Fabric Modules
Product ID |
Description |
Minimum |
Maximum |
N9K-C9504-FM |
Cisco Nexus 9504 40-Gigabit fabric module |
3 |
6 |
N9K-C9508-FM |
Cisco Nexus 9508 40-Gigabit fabric module |
3 |
6 |
N9K-C9516-FM |
Cisco Nexus 9516 40-Gigabit fabric module |
3 |
6 |
N9K-C9504-FM-S |
Cisco Nexus 9504 100-Gigabit fabric module |
4 |
4 |
N9K-C9508-FM-S |
Cisco Nexus 9508 100-Gigabit fabric module |
4 |
4 |
Table 8. Cisco Nexus 9500 Fabric Module Blanks with Power Connector
Product ID |
Description |
Minimum |
Maximum |
Cisco Nexus 9508 Fabric blank with Fan Tray Power Connector module |
|||
Cisco Nexus 9516 Fabric blank with Fan Tray Power Connector module |
Table 9. Cisco Nexus 9500 Supervisor Modules
Supervisor |
Description |
Quantity |
N9K-SUP-A |
1.8-GHz supervisor module with 4 cores, 4 threads, and 16 GB of memory |
2 |
N9K-SUP-A+ |
1.8-GHz supervisor module with 4 cores, 8 threads, and 16 GB of memory |
2 |
N9K-SUP-B |
2.2-GHz supervisor module with 6 cores, 12 threads, and 24 GB of memory |
2 |
N9K-SUP-B+ |
1.9-GHz supervisor module with 6 cores, 12 threads, and 32 GB of memory |
2 |
NOTE: N9K-SUP-A and N9K-SUP-A+ are not supported on Cisco Nexus 9504 and 9508 switches with -R line cards.
Table 10. Cisco Nexus 9500 System Controller
Product ID |
Description |
Quantity |
N9K-SC-A |
Cisco Nexus 9500 Platform System Controller Module |
2 |
Table 11. Cisco Nexus 9500 Fans and Fan Trays
Product ID |
Description |
Quantity |
Table 12. Cisco Nexus 9500 Power Supplies
Product ID |
Description |
Quantity |
Cisco Nexus Switches |
Table 13. Cisco Nexus 9200 and 9300 Fans and Fan Trays
Product ID |
Description |
Quantity |
Cisco Nexus Switches |
Fan 1 module with port-side intake airflow (burgundy coloring) |
|||
Fan 2 module with port-side intake airflow (burgundy coloring) |
|||
Fan 3 module with port-side intake airflow (burgundy coloring) |
|||
|
Fan module with port-side exhaust airflow (blue coloring)
|
||
Fan module with port-side intake airflow (burgundy coloring) |
|||
|
Fan module with port-side exhaust airflow (blue coloring)
|
||
Fan module with port-side intake airflow (burgundy coloring) |
|||
Fan module with port-side intake airflow (burgundy coloring) |
92160YC-X |
||
92160YC-X |
|||
93108TC-FX3P 93180YC-FX3Sb |
|||
Fan module with port-side intake airflow (burgundy coloring) |
93108TC-FX3P 93180YC-FX3Sb |
||
Fan module with port-side exhaust airflow (burgundy coloring) |
aFor specific fan speeds see the Overview section of the Hardware Installation Guide.
b This switch runs with +1 redundancy mode so that if one fan fails, the switch can sustain operation. But if a second fan fails, this switch is not designed to sustain operation. Hence before waiting for the major threshold temperature to be hit, the switch will power down due to entering the fan policy trigger command.
Table 14. Cisco Nexus 9200 and 9300 Power Supplies
Product ID |
Description |
Quantity |
Cisco Nexus Switches |
NXA-PAC-500W-PE |
500-W AC power supply with port-side exhaust airflow (blue coloring) |
2 |
93108TC-EX |
NXA-PAC-500W-PI |
500-W AC power supply with port-side intake airflow (burgundy coloring) |
2 |
93108TC-EX |
N9K-PAC-650W |
650-W AC power supply with port-side intake (burgundy coloring) |
2 |
9332PQ |
N9K-PAC-650W-B |
650-W AC power supply with port-side exhaust (blue coloring) |
2 |
9332PQ |
NXA-PAC-650W-PE |
650-W power supply with port-side exhaust (blue coloring) |
2 |
92160YC-X |
NXA-PAC-650W-PI |
650-W power supply with port-side intake (burgundy coloring) |
2 |
92160YC-X |
NXA-PAC-750W-PE |
750-W AC power supply with port-side exhaust airflow (blue coloring) 1 |
2 |
9336C-FX2 |
NXA-PAC-750W-PI |
750-W AC power supply with port-side exhaust airflow (burgundy coloring) 1 |
2 |
9336C-FX2 |
NXA-PAC-1100W-PE2 |
1100-W AC power supply with port-side exhaust airflow (blue coloring) |
2 |
93240YC-FX2 |
NXA-PAC-1100W-PI2 |
1100-W AC power supply with port-side intake airflow (burgundy coloring) |
2 |
93240YC-FX2 |
NXA-PAC-1100W-PI |
Cisco Nexus 9000 PoE 1100W AC PS, port-side intake |
2 |
93108TC-FX3P |
NXA-PAC-1100W-PE |
Cisco Nexus 9000 PoE 1100W AC PS, port-side exhaust |
2 |
93108TC-FX3P |
NXA-PAC-1900W-PI |
Cisco Nexus 9000 PoE 1900W AC PS, port-side intake |
2 |
93108TC-FX3P |
N9K-PAC-1200W |
1200-W AC power supply with port-side intake airflow (burgundy coloring) |
2 |
93120TX |
N9K-PAC-1200W-B |
1200-W AC power supply with port-side exhaust airflow (blue coloring) |
2 |
93120TX |
NXA-PAC-1200W-PE |
1200-W AC power supply with port-side exhaust airflow (blue coloring) |
2 |
9272Q |
NXA-PAC-1200W-PI |
1200-W AC power supply with port-side intake airflow (burgundy coloring) |
2 |
9272Q |
N9K-PUV-1200W |
1200-W Universal AC/DC power supply with bidirectional airflow (white coloring) |
2 |
92160YC-X |
NXA-PDC-930W-PE |
930-W DC power supply with port-side exhaust airflow (blue coloring) |
2 |
9272Q |
NXA-PDC-930W-PI |
930-W DC power supply with port-side intake airflow (burgundy coloring) |
2 |
9272Q |
NXA-PDC-1100W-PE |
1100-W DC power supply with port-side exhaust airflow (blue coloring) |
2 |
93240YC-FX2 |
NXA-PDC-1100W-PI |
1100-W DC power supply with port-side intake airflow (burgundy coloring) |
2 |
93240YC-FX2 |
UCSC-PSU-930WDC |
930-W DC power supply with port-side intake (green coloring) |
2 |
92160YC-X |
UCS-PSU-6332-DC |
930-W DC power supply with port-side exhaust (gray coloring) |
2 |
92160YC-X |
NXA-PHV-1100W-PE |
1100-W AC power supply with port-side exhaust airflow (blue coloring) |
2 |
93240YC-FX2 |
NXA-PHV-1100W-PI |
1100-W AC power supply with port-side intake airflow (burgundy coloring) |
2 |
93240YC-FX2 |
NXA-PAC-2KW-PE |
2000-W AC power supply with port-side exhaust airflow (blue coloring) |
2 |
9364C-GX |
NXA-PAC-2KW-PI |
2000-W AC power supply with port-side intake airflow (burgundy coloring) |
2 |
9364C-GX |
NXA-PDC-2KW-PE |
2000-W DC power supply with port-side exhaust airflow (blue coloring |
2 |
9364C-GX |
NXA-PDC-2KW-PI |
2000-W DC power supply with port-side intake airflow (burgundy coloring) |
2 |
9364C-GX |
N2200-PAC-400W |
400-W AC power supply with port-side exhaust airflow (blue coloring) |
2 |
92348GC-X |
N2200-PAC-400W-B |
400-W AC power supply with port-side intake airflow (burgundy coloring) |
2 |
92348GC-X |
N2200-PDC-350W-B |
350-W DC power supply with port-side intake airflow |
2 |
92348GC-X |
N2200-PDC-400W |
400-W DC power supply with port-side exhaust airflow (blue coloring) |
2 |
92348GC-X |
Table 15. Cisco Nexus 9200 and 9300 Switches
Table 16. Cisco Nexus 9000 Series Uplink Modules
Cisco Nexus Switch |
Description |
An enhanced version of the Cisco Nexus N9K-M6PQ uplink module. |
|
Cisco Nexus 9300 uplink module with 12 40-Gigabit Ethernet QSPF+ ports. |
To determine which transceivers and cables are supported by a switch, see the Transceiver Module (TMG) Compatibility Matrix. To see the transceiver specifications and installation information, see the Install and Upgrade Guides.
Cisco Network Insights for Data Center
Cisco NX-OS Release 9.3(7) supports the Cisco Network Insights Advisor (NIA) and Cisco Network Insights for Resources (NIR) on Cisco Nexus 9200, 9300-EX, and 9300-FX platform switches and 9500 platform switches with -EX/FX line cards. For more information, see the Cisco Network Insights documentation.
To perform a software upgrade or downgrade, follow the instructions in the Cisco Nexus 9000 Series NX-OS Software Upgrade and Downgrade Guide, Release 9.3(x). For information about an In Service Software Upgrade (ISSU), see the Cisco NX-OS ISSU Support Matrix.
Exceptions
Cisco Nexus 9200, 9300-EX, and 9300-FX Platform Switches
● ACL filters to span subinterface traffic on the parent interface
● FEX (not supported for Cisco Nexus 9200 platform switches)
● GRE v4 payload over v6 tunnels
● IP-in-IP (not supported on the Cisco Nexus 92160 switch)
● Maximum Transmission Unit (MTU) checks for packets received with an MPLS header
● NetFlow (not supported on Cisco Nexus 9200 platform switches)
● Packet-based statistics for Traffic Storm Control (only byte-based statistics are supported)
● PVLANs (not supported on Cisco Nexus 9200 platform switches)
● PXE boot of the Cisco NX-OS image from the loader (not supported for Cisco Nexus 9272PQ and 92160YC switches)
● Q-in-VNI (not supported on Cisco Nexus 9200 platform switches)
● Q-in-Q for VXLAN (not supported on Cisco Nexus 9200 and 9300-EX platform switches)
● Q-in-VNI (not supported on Cisco Nexus 9200 platform switches)
● Resilient hashing for port channels
● SVI uplinks with Q-in-VNI (not supported for Cisco Nexus 9300-EX platform switches)
● Traffic Storm Control for copy-to-CPU packets
● Traffic Storm Control with unknown multicast traffic
● Tx SPAN for multicast, unknown multicast, and broadcast traffic
● VACL redirects for TAP aggregation
Cisco Nexus 9300-FX3 Platform Switches
The following features are not supported for the Cisco Nexus 9300-FX3 Platform switches:
● ACL with DSCP Wildcard Mask
● ARP Suppression with Reflective Relay
● Dynamic ACL - Named ACL support for applying blacklist/limited VLAN access for devices
● ECMP Hashing based on GRE Inner IP Header
● Enhanced ISSU
● Enhanced Policy-Based Routing (ePBR)
● ePBR Multi-Hop
● ePBR with Probes
● ePBR with User-Defined Probes
● IPv6 MIB support (IP-MIB)
● Multicast Service Reflection (Ingress, PIM-border, Egress)
● Multiple LLDP neighbors per physical interface
● Secure VXLAN EVPN Multi-Site using CloudSec
● Selective Q-in-VNI + Advertise PIP on a VTEP
● Selective Q-in-VNI + VXLAN VLAN on the same port
● Standard ISSU
● Symmetric Hashing - ECMP (Inner DA)
● Unidirectional Ethernet (UDE)
● VXLAN EVPN with downstream VNI
● VXLAN over parent interface that also carries sub-interfaces
Cisco Nexus 9300-GX Platform Switches
The following features are not supported for the Cisco Nexus 9300-GX platform switches:
● Autonegotiation on all ports
● FC-FEC for Cisco Nexus 9316D-GX and 93600CD-GX switches is not supported on the second lane of the 50x2 breakout port.
● FEX
● Multicast over GRE
Cisco Nexus N9K-X9408PC-CFP2 Line Card and 9300 Platform Switches
● FEX (supported on some Cisco Nexus 9300 platform switches)
● Flows other than 40G
● Multichassis EtherChannel Trunk (MCT)
● Precision Time Protocol (PTP)
● PVLAN (supported on Cisco Nexus 9300 platform switches)
● Shaping support on 100g port is limited
● SPAN destination/ERSPAN destination IP
FEX Modules
The following features are not supported for FEX modules:
● Active-Active FEX and straight-through FEX are not supported on the Cisco Nexus 92348GC switch.
● For Cisco Nexus 9500 platform switches, 4x10-Gb breakout for FEX connectivity is not supported.
Cisco Nexus N9K-X96136YC-R Line Card
Cisco Nexus N9K-X9736C-FX Line Card
● Ports 29-36 do not support 1 Gbps speed.
Cisco Nexus 9500 Cloud Scale (EX/FX) Line Cards
The following features are not supported for Cisco Nexus 9500 platform switches with -EX/FX line cards:
● IPv6 support for policy-based routing
● SPAN port-channel destinations
Cisco Nexus 9000 Series documentation: Cisco Nexus 9000 Series Switches
Cisco Nexus 9000 and 3000 Series NX-OS Switch License Navigator: Cisco Nexus 9000 and 3000 Series NX-OS Switch License Navigator
Cisco Nexus 9000 Series Software Upgrade and Downgrade Guide: Cisco Nexus 9000 Series NX-OS Software Upgrade and Downgrade Guide, Release 9.3(x)
Cisco Nexus 9000 Series FPGA/EPLD Upgrade Release Notes: Cisco Nexus 9000 Series FPGA/EPLD Upgrade Release Notes, Release 9.3(7)
Cisco Nexus 3000 and 9000 Series NX-API REST SDK User Guide and API Reference: Cisco Nexus NX-API Reference
Cisco NX-OS Supported MIBs: ftp://ftp.cisco.com/pub/mibs/supportlists/nexus9000/Nexus9000MIBSupportList.html
Supported FEX modules: Cisco Nexus 9000 Series Switch FEX Support Matrix
Licensing Information: Cisco NX-OS Licensing Guide
To provide technical feedback on this document, or to report an error or omission, please send your comments to nexus9k-docfeedback@cisco.com. We appreciate your feedback.
Legal Information
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1721R)
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.
© 2021 Cisco Systems, Inc. All rights reserved.