The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.

Available Languages

Download Options

  • PDF
    (4.4 MB)
    View with Adobe Reader on a variety of devices
Updated:April 26, 2022
 

 

Introduction

Cisco Nexus Dashboard Fabric Controller (NDFC) is an application that runs on the Nexus Dashboard (ND) and enables controlling, automating, monitoring, visualization, and troubleshooting of networks built on the Cisco Nexus Data Center switches.

Nexus Dashboard Insights (NDI) is a unified monitoring and analytics tool that reduces mean time to detect (MTTD) and mean time to resolve (MTTR) network issues by providing comprehensive visibility into the infrastructure, reliable issue analysis, and definitive suggestions for addressing day2 operation challenges of complex data center networks. Nexus Dashboard Insights processes and analyzes telemetry data continuously streamed from all the devices in the infrastructure to provide network operators with real-time monitoring and analytics of the network. It also offers lifecycle management suggestions and foresight into infrastructure change management.

This paper details the best deployment configurations, and settings to implement Nexus Dashboard Insights for your NDFC managed or monitored NX-OS network sites. To enable streaming telemetry data from all the devices on the sites, specific configurations and pre-requisite settings are required on NDFC and devices. We use a typical two-tier (spine and leaf) network fabric as an example in this white paper to illustrate the necessary configuration on the NDFC controller and the switches to prepare the sites for Nexus Dashboard Insights. As a network site can be fully managed or only monitored by NDFC, the white paper discusses the configuration for both the NDFC managed mode and monitored mode.

DiagramDescription automatically generated

Software and Hardware Product Versions

The example in this white paper has the following product software versions:

     Nexus Dashboard Fabric Controller version 12.0.2f

     Nexus Dashboard version 6.0.2.1928

     Nexus Dashboard Insights version 2.1(2d)

For more information about supported software versions and compatibilities of related products, refer to the Cisco Nexus Dashboard and Services Compatibility Matrix at the following link: https://www.cisco.com/c/dam/en/us/td/docs/dcn/tools/dcn-apps/index.html.

For support of the required features, we are using all cloud-scale switches.

NDFC and NDI co-hosting on the same ND cluster is not supported for the above versions. Co-hosting both the applications on the same ND cluster will be supported in future releases.

As both NDFC and NDI applications are running on separate ND clusters, ND-NDFC and ND-NDI will be used to context switch between the two applications.

Pre-Requisites for NDFC Sites Configuration

Nexus Dashboard nodes provide the following two interfaces for connectivity:

     Management or Out-of-band or bond1br Interface

     Data or Fabric or in-band or bond0br Interface

ND-NDFC nodes require one IP each for the above two interface types from their respective subnets. The clusters must be Layer-2 adjacent respectively on the two interfaces.

To configure NDFC, refer to configuration guides located at https://www.cisco.com/c/en/us/support/cloud-systems-management/nexus-dashboard-fabric-controller-12/model.html.

For NDFC deployments and considerations along with DCNM to NDFC migration, refer to https://www.cisco.com/c/en/us/td/docs/dcn/whitepapers/cisco-nexus-dashboard-fabric-controller-deployment-guide.html.

Below is the summary of pre-requisites to prepare NDFC and its managed or monitored network sites for onboarding onto the Nexus Dashboard and use with Nexus Dashboard Insights:

     Configure routable loopback interfaces on switches for NDI hosting ND data network connectivity

Nexus Dashboard data network needs IP reachability to the network site and the NDFC. A routable loopback interface is used on the network site switches for this connectivity and to source telemetry data. We could use a dedicated loopback interface or an existing loopback interface on the switches. Configuring or usage of a loopback interface for both monitored and managed modes are discussed in further sections.

The round-trip time (RTT) between the Nexus Dashboard cluster and the network site must not exceed 50ms for Nexus Dashboard Insights to run for the network site properly.

     Enable and Configure NTP (Network Time Protocol) in the network

NTP is an essential clock service that syncs all the elements of the network site. NTP service is not only required for setting up the NDFC cluster and managing network site switches, but also for software telemetry to work. It maintains the consistency and coherence of logs between the switches and the NDFC controller. NTP configurations and verifications for monitored and managed modes are discussed in further sections.

     Enable and Configure PTP (Precision Time protocol) in the network

Nexus Dashboard Insights requires a microsecond-level accurate PTP clock for the network site to perform flow analytics across the site and calculate the end-to-end network latency of the flows.

For NDFC managed or monitored NX-OS network site, the PTP grandmaster needs to be an external device that can provide at least a microsecond-level clock.

The PTP configurations and verifications are discussed in the next sections for both NDFC managed and monitored network sites.

The following sections discuss in detail the configuration and verification for each of the pre-requisite requirements.

Prepare NDFC Managed Network Sites for Nexus Dashboard Insights

NDFC supports managed mode which requires discovering nodes, adding them to a fabric and assigning fabric roles. In managed mode, NDFC manages the switch configuration. It deploys the config-profiles based on a set of inputs provided in the fabric building process and monitor the network site.

This section will help prepare an NDFC managed network site for Nexus Dashboard and Nexus Dashboard Insights. It details each of the below steps in order:

     Create fabric

     Discover switches

     Create routable loopback interfaces on switches

     Configure NTP

     Configure PTP

Create Fabric

This section allows you to create a controlled SDN fabric that can be managed and monitored by NDFC.

1.     On the Fabric Controller UI, choose LAN > Fabrics. From the Actions drop-down list, select Create Fabric.

Graphical user interface, application, tableDescription automatically generated

2.     Enter the Fabric Name.

Graphical user interface, text, applicationDescription automatically generated

3.     Click Choose Template. Select the template of interest and click Select. NDFC supports multiple fabric types of fabrics (for example: LAN classic, VxLAN fabrics and so on).

For this paper we use a VxLAN fabric.

4.     In the Select Fabric Template pop-up choose Easy_Fabric template to add a managed VxLAN fabric.

Graphical user interface, text, applicationDescription automatically generated

5.     Enter appropriate values for the chosen template. For example: Easy_Fabric. Click Save to submit the configuration.

Graphical user interface, applicationDescription automatically generated

Refer to Easy Provisioning of VxLAN BGP EVPN Fabrics in the Cisco Nexus Dashboard Fabric Controller for LAN Configuration Guide for more details on how to create and configure a VxLAN BGP EVPN Fabric on NDFC.

Discover Switches in the Fabric

NDFC uses a single seed or multiple IPs in the fabric and dynamically discover the switches for a set number of hops defined in ‘Max Hops’ or also a list of all switch IPs in the fabric with a hop count ‘0’. It allows you to select the switches to be added to the fabric.

1.     On the Fabric Controller UI, choose LAN > Switches. From the Actions drop-down list, select Add Switches.

Graphical user interface, text, application, email, websiteDescription automatically generated

2.     On the Add Switches screen, click Choose Fabric to choose a fabric to which the switches must be associated.

Graphical user interface, text, applicationDescription automatically generated

3.     Select the fabric intended to discover the switches and click Select.

Graphical user interface, applicationDescription automatically generated

4.     Provide a seed IP (management IP) of any switch in the fabric to be discovered. Choose the Authentication protocol used to login to switches and provide Username/Password. Select the number of hops from the seed to determine the detection boundary. Check the Preserve Config check box to keep the existing configs on the switch (brownfield deployment) or uncheck the option to clean up the configuration on the switches (greenfield. deployment).

Graphical user interface, applicationDescription automatically generated

5.     Click Discover Switches.

6.     Select all the switches intended to be part of the fabric and click on Add Switches.

7.     Chose LAN > Switches to ensure that the switches are discovered and are associated with the correct fabric. You can also choose LAN > Fabrics. Double click on the fabric to view Fabric Overview. Click on Switches tab to view the switches associated with the specific Fabric.

Graphical user interfaceDescription automatically generated

8.     On the Switches page, click Actions > Set Role to assign roles to the switches.

Alternatively, on the Topology page, right click on the appropriate switch and assign roles.

Graphical user interface, applicationDescription automatically generated

9.     From the pop-up choose the intended role and click Select.

Graphical user interface, applicationDescription automatically generated

10.  After setting the role, on the Switches page. select the switches and click Actions > Deploy.

Graphical user interface, tableDescription automatically generated

11.  From the Deploy Configuration screen, preview the configurations by clicking on Pending Config and click Deploy to be guided to deployment progress screen.

Graphical user interface, application, tableDescription automatically generated

Configure Routable Loopback Interface on Switches

For managed easy fabrics, NDFC deploys an underlay routing loopback and VTEP loopback on the switches. To deploy Nexus Dashboard Insights for the NDFC site, either of the loopback is leveraged when there is IP reachability to the data network of the Nexus Dashboard cluster.

1.     Choose LAN > Fabrics. From Actions drop-down list, choose Edit Fabric.

Graphical user interface, applicationDescription automatically generated

2.     On the Protocols tab and enable loopback IDs. Click Save.

Graphical user interface, application, emailDescription automatically generated

3.     Save and deploy the fabric to get loopback IDs created.

4.     Login to the switch to check if the loopback mentioned above is created on the switches and can ping the Nexus Dashboard cluster.

leaf11# show run interface loopback 0

interface loopback0 >>> Check if the loopback 0 is created

  description Routing loopback interface

  ip address 10.2.0.1/32 >>> IP address dynamically allocated

  ip router ospf UNDERLAY area 0.0.0.0

  ip pim sparse-mode

 

leaf11# show interface loopback 0

loopback0 is up >>> Check status of the loopback 0

admin state is up,

  Hardware: Loopback

  Description: Routing loopback interface

  Internet Address is 10.2.0.1/32

  MTU 1500 bytes, BW 8000000 Kbit , DLY 5000 usec

  reliability 255/255, txload 1/255, rxload 1/255

  Encapsulation LOOPBACK, medium is broadcast

  Auto-mdix is turned off

    346284 packets input 30982434 bytes

    0 multicast frames 0 compressed

    0 input errors 0 frame 0 overrun 0 fifo

    0 packets output 0 bytes 0 underruns

    0 output errors 0 collisions 0 fifo

    0 out_carrier_errors

 

leaf11# ping 192.168.1.201 source-interface loopback 0 >> checking reachability to the Nexus Dashboard

PING 192.168.1.201 (192.168.1.201): 56 data bytes

64 bytes from 192.168.1.201: icmp_seq=0 ttl=62 time=0.738 ms

64 bytes from 192.168.1.201: icmp_seq=1 ttl=62 time=0.45 ms

64 bytes from 192.168.1.201: icmp_seq=2 ttl=62 time=0.483 ms

64 bytes from 192.168.1.201: icmp_seq=3 ttl=62 time=0.429 ms

64 bytes from 192.168.1.201: icmp_seq=4 ttl=62 time=0.367 ms

 

--- 192.168.1.201 ping statistics ---

5 packets transmitted, 5 packets received, 0.00% packet loss

round-trip min/avg/max = 0.367/0.493/0.738 ms

Network Time Protocol (NTP) Configuration

For a network site managed by NDFC, enable and configure NTP on the NDFC. The NDFC will push the NTP configs to all the switches.

1.     On the NDFC UI, choose LAN > Fabrics. Select the fabric (SJ-Managed).

2.     From Actions drop-down list, choose Edit Fabric.

Graphical user interface, applicationDescription automatically generated

3.     Click on Manageability tab to fill in the NTP server IP and VRF details and click Save.

Graphical user interface, text, application, emailDescription automatically generated

4.     Click on LAN > Topology. Select Fabric (SJ-Managed). From Actions drop-down list, select Recalculate and Deploy.

Graphical user interfaceDescription automatically generated

5.     Toggle on the Configuration to see the switches turn green (Success).

Graphical user interface, applicationDescription automatically generated

Precision Time Protocol (PTP) Configuration

When PTP is enabled, it becomes the default clock even if NTP is enabled on the switches. PTP requires a source loopback used for exchanging PTP packets and a PTP domain ID that defines boundaries of the PTP messages. NDFC offers easy site setup for enabling PTP.

1.     Choose LAN > Fabrics. Select the fabric (SJ-Managed). From the drop-down list, select Edit Fabric.

Graphical user interface, applicationDescription automatically generated

2.     Click on Advanced tab and select Enable Precision Time Protocol (PTP). Provide the PTP source loopback ID, PTP domain ID. Click Save.

This enables PTP globally and on core-facing interfaces.

Graphical user interface, application, emailDescription automatically generated

 

Graphical user interface, text, application, emailDescription automatically generated

3.     Choose LAN > Topology. Select Fabric (SJ-Managed). From the Actions drop-down list, click Recalculate and Deploy to ensure switches are configured with the required PTP settings as configured in the NDFC.

Graphical user interfaceDescription automatically generated

4.     After the switches turn green (Success), login to the switches to confirm the configuration and clock settings.

Graphical user interface, applicationDescription automatically generated

Prepare NDFC Monitored Network Sites for Nexus Dashboard Insights

NDFC supports monitored mode which requires discovering nodes and adding them to a fabric. In monitored mode, NDFC does not manage the switch configuration and typically only helps monitor the fabric. This mode can work complementary to any configuration tools and methods used as it is agnostic of the switch configurations. For a NDFC monitored network site, users need to deploy and verify the needed switch configuration for Nexus Dashboard and Nexus Dashboard Insights by themselves.

This section helps to prepare a NDFC monitored fabric for Nexus Dashboard and Nexus Dashboard Insights. It details each of the below steps in order:

     Create fabric

     Discover switches

     Configure Routable Loopback Interfaces on the switches

     Configure NTP

     Configure PTP

Create Fabric

This section shows you how to create a NDFC monitored fabric.

1.     Choose LAN > Fabrics. From the Actions drop-down list, select Create Fabric.

The Add Fabric screen appears.

Graphical user interface, applicationDescription automatically generated

2.     Enter fabric name and click Choose Template.

Graphical user interface, text, applicationDescription automatically generated

NDFC supports multiple fabric types (for example: LAN classic, VxLAN fabrics and so on). For this section we use a monitored VxLAN fabric as an example.

3.     Choose External_Fabric template to add a monitored VxLAN fabric.

Graphical user interface, text, applicationDescription automatically generated

4.     In the General Parameters tab, populate the BGP AS# used in the site.

5.     Check the Fabric Monitor Mode check box to enable Fabric in monitored mode.

6.     Click Save.

Graphical user interface, text, application, emailDescription automatically generated

Note:       Since the fabric is only monitored by the NDFC, switches on this fabric are expected to be configured by the user and NDFC does not deploy any configurations to the switches in this mode.

Discover Switches in the Fabric

NDFC can use a single seed or multiple IPs in the fabric and dynamically discover the switches for a set number of hops defined in Max Hops or also a list of all switch IPs in the fabric with a hop count ‘0’ can also serve the purpose. It allows selection of switches to be added to the fabric.

1.     Choose LAN > Switches. From the Actions drop-down list, select Add Switches.

Graphical user interface, text, application, email, websiteDescription automatically generated

The above step will pop-up a new window to allow user to choose a fabric that the discovered switches will belong to.

2.     Click Choose Fabric.

Graphical user interface, text, applicationDescription automatically generated

3.     From the list of Fabrics, select the fabric intended to discover the switches to. Click Select.

Graphical user interface, text, applicationDescription automatically generated

4.     Enter a seed IP (management IP) of any switch in the fabric to be discovered. Choose the Authentication Protocol used to login to switches and provide Username/Password. Select the number of hops from the seed to determine the detection boundary.

Related image, diagram or screenshot

5.     Click Discover Switches.

6.     Select all the switches intended to be part of the fabric and click Add Switches.

Graphical user interface, applicationDescription automatically generated

7.     Click LAN > Switches. The Switches that are discovered and part of the fabric intended are displayed. You can view the switches associated with the Fabric from LAN > Fabrics > Fabrics Overview > Switches tab also.

TableDescription automatically generated

After the switches are added to the fabric, assign roles to the switches by selecting the switch/switches and choosing the intended role, such as Spine, Leaf, Border Gateway and so on.

8.     Click on LAN > Switches. Double click on the switch to view Switch Overview. From Actions drop-down list, select Set Role.

Configure a Routable Loopback Interface on Switches

Each switch in the network site needs a routable loopback interface to source the telemetry data to the Nexus Dashboard Insights. Any existing loopback on the switches with the required IP connectivity to the Nexus Dashboard Data Network could be used or users can create a new loopback for the purpose.

For a NDFC monitored fabric, users need to configure and manage such a loopback interface on the switches by themselves. Below shows the procedure.

1.     Configure a loopback interface on the switches

leaf21(config)# interface loopback 0

leaf21(config-if)# description Routing loopback interface

leaf21(config-if)# ip address 20.2.0.1/32

leaf21(config-if)# ip router ospf underlay area 0.0.0.0

 

leaf21# show run interface loopback 0 >> check for

interface loopback0

  description Routing loopback interface

  ip address 20.2.0.1/32

  ip router ospf underlay area 0.0.0.0

 

leaf21# show interface loopback 0

loopback0 is up

admin state is up,

  Hardware: Loopback

  Description: Routing loopback interface

  Internet Address is 20.2.0.1/32

  MTU 1500 bytes, BW 8000000 Kbit , DLY 5000 usec

  reliability 255/255, txload 1/255, rxload 1/255

  Encapsulation LOOPBACK, medium is broadcast

  Auto-mdix is turned off

    1031148 packets input 96462171 bytes

    0 multicast frames 0 compressed

    0 input errors 0 frame 0 overrun 0 fifo

    0 packets output 0 bytes 0 underruns

    0 output errors 0 collisions 0 fifo

    0 out_carrier_errors

2.     Check if the loopback created can reach the Nexus Dashboard Data Network by pinging the Nexus Dashboard Data Network IP address from the loopback interface. In the example below, the IP address 192.168.1.201 is one of the Nexus Dashboard Data Network IP addresses. If there is no firewalls or other network devices blocking the ICMP traffic, the ping should succeed.

leaf21# ping 192.168.1.201 source-interface loopback 0 

PING 192.168.1.201 (192.168.1.201): 56 data bytes

64 bytes from 192.168.1.201: icmp_seq=0 ttl=62 time=0.56 ms

64 bytes from 192.168.1.201: icmp_seq=1 ttl=62 time=0.431 ms

64 bytes from 192.168.1.201: icmp_seq=2 ttl=62 time=0.38 ms

64 bytes from 192.168.1.201: icmp_seq=3 ttl=62 time=0.449 ms

64 bytes from 192.168.1.201: icmp_seq=4 ttl=62 time=0.379 ms

 

--- 192.168.1.201 ping statistics ---

5 packets transmitted, 5 packets received, 0.00% packet loss

round-trip min/avg/max = 0.379/0.439/0.56 ms

Note:       For an effective verification, make sure the ping is sourced from the Loopback interface.

Network Time Protocol (NTP) Configuration

You must enable NTP and configure the NTP server on each switch in the network site that’s monitored by the NDFC, also need to make sure all the switches have the consistent NTP configuration and is synced to the same NTP server.

In NDFC monitored mode, all the switches in the network site must be configured with an NTP server.

spine12# config terminal

Enter configuration commands, one per line. End with CNTL/Z.

spine12(config)# ntp server 72.163.32.44 use-vrf management

Precision Time Protocol (PTP) Configuration

For NDFC managed or monitored network site, an external PTP grandmaster that provides a clock source with at least microsecond accuracy is required. When PTP is enabled, it is the default clock even if NTP is enabled on the switches. PTP requires a source loopback used for exchanging PTP packets and a PTP domain ID that defines the boundaries of the PTP messages.

For NDFC monitored network site, you must configure PTP on each network switch as NDFC doesn’t manage the switch configuration. This section describes how to configure PTP on an NX-OS switch. 

1.     Enable feature PTP:

leaf21# configure terminal

Enter configuration commands, one per line. End with CNTL/Z.

leaf21(config)#  feature ptp  -> Enabling feature ptp

2.     Configure PTP domain ID and PTP source interface (a routable loopback)

leaf21(config)# ptp domain 1  -> PTP domain ID

leaf21(config)# ptp source 10.2.0.1-> PTP source IP

3.     Configure PTP under core facing interfaces and ttag under Host facing interfaces:

interface Ethernet1/1  -> Core facing interface

  ptp

interface Ethernet1/33 -> host facing interface

  ttag

  ttag-strip

NTP and PTP verifications

With either managed or monitored mode fabrics, verifications on the switch remain the same.

     NTP verifications: Login to the switches to confirm the configuration and clock settings. Verify below commands for NTP setup on the switch as the clock time source.

leaf21(config)# show run ntp

!Command: show running-config ntp

!No configuration change since last restart

!Time: Sun Feb 6 21:54:40 2022

version 9.3(7) Bios:version 05.40

ntp server 72.163.32.44 use-vrf management -> Verify the configuration

 

leaf11(config)# show clock

21:53:34.997 UTC Sun Feb 6 2022

Time source is NTP -> Verify NTP is the time source

 

leaf11(config)# show ntp peers

----------------------------------------------------

     Peer IP Address          Serv/Peer

----------------------------------------------------

     72.163.32.44         Server (configured)  -> Verify the server is configured

     PTP Verifications: After enabling PTP either through NDFC or CLI configurations, verify below commands for PTP on the switch as the clock time source.

leaf11# show run ptp

feature ptp. -> Verify that PTP is enabled and configured on the interfaces

ptp source 10.0.0.1

ptp domand 0

interface Ethernet1/1

    ptp

interface Ethernet1/33

    ttag

    ttag-strip

leaf11# show clock

01:56:04.353 UTC sun Feb 6 2022

Time source is PTP -> Verify PTP is the time source

 

leaf11# show ptp clock foreign-masters record

P1=Priority1, P2=Priority2, C=Class, A=Accuracy,

OSLV=Offset-Sclaed-Log-Variance, SR=Steps-Removed

GM=Is grandmaster

 

----------   -------------------   ---   ----   ----   ---   -----   ----------

Interface         Clock-ID         P1    P2     C      A     OSLV    SR

----------   -------------------   ---   ----   ----   ---   -----   ----------

Eth1/1    2c:4f:52:ff:fe:56:61:1f  255   255    248    254   65535   1

 

-> Verify if it can reach the grand master on its ptp configured interfaces

 

leaf11# show ptp clock

PTP Device Type : boundary-clock

PTP Device Encapsulation : NA

PTP Source IP Address : 10.2.0.1  -> Verify if source loopback IP is as configured

Clock Identity : d4:78:9b:ff:fe:19:87:c3

Clock Domain: 0

Slave Clock Operation : Two-step

Master Clock Operation : Two-step

Clave-Only Clock Mode : Disabled

Number of PTP ports: 3

Priority1 : 255

Priority2 : 255

Clock Quality:

        Class : 248

        Accuracy : 254

        Offset (log variance) :

Offset From Master : 12

Mean Path Delay : 168

Steps removed : 2

Correction range : 100000

MPD range : 1000000000

Local clock time: Fri Aug 27 01:56:08 2021

PTP clock state             : Locked

 

leaf11# show ptp parent

PTP PARENT PROPERTIES

Parent Clock:

Parent Clock Identity: 2c:4f:52:ff:fe:56:61:1f

Parent Port Number: 4

Observed Parent Offset (log variance): NA

Observed Parent Clock Phase Change Rate: N/A

 

Parent IP: 10.2.0.4

Grandmaster Clock:

Grandmaster Clock Identity: 00:ee:ab:ff:fe:3a:16:e7  -> Get the Grandmaster clock ID

Grandmaster Clock Quality

        Class : 248

        Accuracy : 254

        Offset (log variance) : 65535

        Priority1: 255

        Priority2: 255

spine12# show ptp clock foreign-masters record

P1=Priority1, P2=Priority2, C=Class, A=Accuracy,

OSLV=Offset-Scaled-Log-Variance, SR=Steps-Removed

GM=Is grandmaster

----------   ---------------------   ---   ----   ----   ---   -----   ----------

Interface         Clock-ID           P1    P2     C      A     OSLV    SR

----------   ---------------------   ---   ----   ----   ---   -----   ----------

Eth1/4     00:ee:ab:ff:fe:3a:16:e7   255   255    248    254   65535   1      GM

-> Check the Grandmaster clock ID and confirm the right Grandmaster registration on clients

Onboarding NDFC Network Site to Nexus Dashboard

Before adding an NDFC network site to Nexus Dashboard, the following status need to be confirmed:

     All NDFC servers are healthy: OK

     Nexus dashboard cluster has configured fabric connectivity and has cluster health: OK

The following procedure provides instructions to add NDFC site to the Nexus Dashboard:

1.     On Nexus Dashboard UI, click Admin Console > Sites > Add Site.

Graphical user interface, applicationDescription automatically generated

2.     Select Site Type as NDFC. In the Hostname/IP address field provide the NDFC in-band IP address configured on the ‘eth2’ interface of the NDFC server. Provide Username and Password of the NDFC server.

Graphical user interface, text, application, emailDescription automatically generated

3.     Click Select Sites to choose the sites to onboard onto the Nexus Dashboard. Click Select.

Graphical user interface, applicationDescription automatically generated

 

Chosen sites now are onboarded onto the Nexus Dashboard.

Graphical user interface, text, application, email, websiteDescription automatically generated

Enabling Nexus Dashboard Insights for a NDFC Network Site

The below workflow shows tasks involved to enable Nexus Dashboard Insights service for a NDFC network site:

     Configure the required persistent IP addresses on the Nexus Dashboard

     Install and Enable the Nexus Dashboard Insights service on the Nexus Dashboard (only required if the Insights service has not been installed or enabled yet).

     Enable the Nexus Dashboard Insights service for the site

Configuring persistent IP addresses in Nexus Dashboard

Nexus Dashboard Insights requires 6 mandatory persistent IP addresses for software and hardware telemetry services for a NDFC managed or monitored network site. The 6 persistent IP addresses are assigned to 3 UTR (Software Telemetry) application services and 3 flow collector (Hardware Telemetry) application services. These are mandatory for Nexus Dashboard Insights operations. A 7th persistent IP address is required if IPv6 is used for the assurance data collection and transport between the network site and the Nexus Dashboard. These persistent IP addresses help with retaining the same IP addresses for the Nexus Dashboard Insights services even if the internal microservice pods are relocated to different Nexus Dashboard nodes.

These persistent IP addresses are in the Nexus Dashboard Data Network subnet. They must be configured on the Nexus Dashboard prior to enabling the Nexus Dashboard Insights app.

1.     On the Nexus Dashboard UI, click Admin Console

TextDescription automatically generated with medium confidence

2.     Choose Infrastructure > Cluster Configuration.

3.     Edit External Service Pools to add 6 IP addresses from the data network subnet.

Graphical user interface, applicationDescription automatically generated

4.     Click Save.

After the persistent IP addresses are added to the Nexus Dashboard, the Nexus Dashboard Insights App can be installed and enabled on the Nexus Dashboard.

Note:       If Nexus Dashboard Insights is used for a NDFC managed/monitored network site, it’s required that the Nexus Dashboard nodes are Layer-2 adjacent to one another in the Data Network. In another word, the Nexus Dashboard nodes need to be in the same IP subnet for their Data Network.  This is needed to allow the persistent IP addresses to move among the Nexus Dashboard nodes.

Installing and Enabling Nexus Dashboard Insights App

1.     Choose Admin Console > Services > App Store tab.

You can Install the Nexus Dashboard Insights App.

Graphical user interface, application, websiteDescription automatically generated

If the Nexus Dashboard cannot reach the Cisco App Store directly due to network connectivity constrains, you can install Nexus Dashboard Insights app offline.

2.     Download the application from the Cisco DC App Center at https://dcappcenter.cisco.com/ to your local directory or a web server. To install the app on the Nexus Dashboard, perform the following steps:

a.     On the Nexus Dashboard UI, choose Admin Console > Services > Installed Services.

b.    Click Actions and choose Upload Service.

c.     On Upload Service screen, choose Local for location if the app image file is on your local computer. Alternatively, choose Remote if the app file is on a webserver, then provide the URL for the file.

d.    Click Upload button to start the upload and installation.

Graphical user interface, text, application, emailDescription automatically generated

3.     After Nexus Dashboard Insights is installed, click Enable.

Graphical user interface, applicationDescription automatically generated

4.     Choose the deployment profile. Select the appropriate profile by reading the description and complying to the Resource Requirement provided for each of the Deployment Profile. Click Enable again to apply certificates and start services required for Nexus Dashboard Insights.

Graphical user interface, applicationDescription automatically generated

For more information, refer to Nexus Dashboard Insights User Guide.

Enabling Nexus Dashboard Insights Service for NDFC Site

Perform this procedure on the Nexus Dashboard Insights UI.

1.     Create a site group and add the NDFC site to the group.

If this is the first site group on the Nexus Dashboard Insights, the following screen is displayed to guide the user to add the site group.

2.     Click on Configure Site Group on the screen to start the process.

Graphical user interface, text, application, websiteDescription automatically generated

Alternatively, click on the gearbox on the top right corner, and select Site Groups > Manage. Select Add New Site Group.

3.     Click Configure Site Groups and review the prerequisites for Insights.

4.     Click Let’s Get Started > Configure > Add New Site Group to provide a Name for the Site group.

5.     Select Add Site(s). Click on +Add Member > Select Member to select the sites from Nexus Dashboard. Chose the site to be added.

6.     Click Select.

Graphical user interface, application, emailDescription automatically generated

7.     After the site is added to the Site Group, click Enable and configure.

8.     Enter the fabric type and credentials.

9.     Provide the Loopback interface information that is configured in the previous section.

This Loopback interface IP address must be reachable to the Nexus Dashboard Data Network.

10.  Click Save. The status changes to Enable.

11.  Click on the menu (…) option and select Configure Site Group to view the site that is enabled with Nexus Dashboard Insights services.

Graphical user interface, application, websiteDescription automatically generated

Enabling Bug Scan, Best Practices, and Assurance Analysis

1.     After the site-group is configured, to enable Bug Scan feature, click Bug Scan > (Edit) > Enabled and provide parameters for the Start and End time along with frequency of scan.

2.     Click Save.

3.     Click Run Now to initiate bug scan.

Related image, diagram or screenshot

4.     To enable Best Practices checks, click on Best Practices > (Edit) > Enabled and provide parameters for Start and End time along with frequency of best practice checks.

5.     Click Save.

6.     Click Run Now to initiate an instant best practice check in the requested site.

Related image, diagram or screenshot

7.     To enable Assurance Analysis, click on Assurance Analysis > (Edit) > Enabled and provide parameters for Start and End time along with frequency of best practice checks and timeout parameter for how long to run the job.

8.     Click Save.

9.     Click Run Now to initiate an instant Assurance Analysis in the requested site.

Related image, diagram or screenshot

Enabling Software and Flow Telemetry

Nexus Dashboard Insights provides intuitive and simple software and flow telemetry enabling with NDFC network sites.

Enabling Software Telemetry

1.     When configuring the site-group, after the site is enabled and Configuration Status is OK, Nexus Dashboard Insights generates the required configuration per switch to enable software telemetry.

In NDFC managed mode, the generated software telemetry configurations are automatically deployed on the switches. In NDFC monitored mode, the switches must be manually configured with the generated configurations.

2.     To check the status of the software telemetry configuration for NDFC managed sites, click on Node Status and select the node to see Success for successful operation of configuration.

Related image, diagram or screenshot

3.     To fetch generated configurations to use for NDFC monitored mode network sites, click on the visual statuses under Node Status.

Graphical user interface, application, TeamsDescription automatically generated

4.     Click on any switch/node and check for SOFTWARE TELMETRY CONFIGURATION STATUS under Status.

Graphical user interface, applicationDescription automatically generated

5.     To fetch the auto-generated configurations, click View Expected Configuration > Software Telemetry tab. To copy the configuration to the clipboard, click Copy Configuration.

Graphical user interface, text, application, emailDescription automatically generated

6.     Repeat the process for each of the switches in the NDFC monitored mode network site.

Enabling Flow Telemetry

1.     In the Configure Site Group page, click Flows > (Edit) on the desired site.

2.     Choose the desired flow collection mode.

Graphical user interface, application, TeamsDescription automatically generated

3.     Under the Flow Telemetry Rules create a rule name and then populate the 5-tuple information

Graphical user interface, applicationDescription automatically generated with medium confidence

4.     Click Save.

NDI auto-generates the configurations required on the switches in the network sites for enabling the created rules.

If the network sites are in NDFC managed mode, the auto-generated flow telemetry configurations are auto deployed on the switches by NDFC. If the sites are in NDFC monitored mode, the required configuration must be deployed to the switches.

5.     To fetch the auto-generated configuration, in the Configure Site Group page click on General > Site under Collection Status -> Node Status   -> Switch/Node -> View Expected Configuration.

Graphical user interface, applicationDescription automatically generated

6.     Select Flow Telemetry tab.

Configuration with ACLs per rules created in the previous step is auto-generated along with collector information, bucket IDs, ports and other parameters such as filters and frequency of information collection.

Related image, diagram or screenshot

It copies configuration to the default clipboard. Use it to configure the switch in NDFC monitored mode network site.

7.     Repeat the process for all the switches in the NDFC monitored mode network site.

Verifying Software and Flow Telemetry configurations

Verifications on the Nexus Dashboard Insights

In the NDFC managed mode, the configurations auto generated by NDI to enable software and flow telemetry would be deployed on all the switches in the site and status would reflect success on clicking on the status for each of the switches.

Graphical user interface, text, application, emailDescription automatically generated

In the NDFC monitored mode, although the configurations are auto generated by NDI to enable software and flow telemetry the configuration on the switches is manual. The status in this case would be monitoring.

Graphical user interface, text, application, emailDescription automatically generated

Verifications on Switches in the Network Site

Whether the switches are configured manually in NDFC monitored mode or configurations are auto deployed in NDFC managed mode, switch verification methods remain consistent for the two modes.

Software Telemetry Configuration Verifications:

Run show run telemetry on each of the switches to match the configuration to NDI-generated configuration.

Verify the correct receiver IP and port are configured on the switch and is connected.

spine21# show telemetry transport

Session Id      IP Address      Port       Encoding     Transport  Status   

--------------------------------------------------------------------------------

0               192.168.1.71    57500      GPB-compact  gRPC       Connected

0               192.168.1.71    57500      GPB          gRPC       Connected

--------------------------------------------------------------------------------

Retry buffer Size:             10485760           

Event Retry Messages (Bytes):  0                  

Timer Retry Messages (Bytes):  0                  

Total Retries sent:            0                  

Total Retries Dropped:         0                  

Hardware Telemetry Configuration Verifications:

Verify that collectors, port and ACL information are configured.

 

Expected Running-Configuration

Configured status

Collectors

flow exporter telemetryExp_0

  destination 192.168.1.75

  transport udp 5640

  source loopback0

  dscp 44

flow exporter telemetryExp_1

  destination 192.168.1.73

  transport udp 5640

  source loopback0

  dscp 44

flow exporter telemetryExp_2

  destination 192.168.1.74

  transport udp 5640

  source loopback0

  dscp 44

spine21# show flow exporter

Flow exporter telemetryExp_0:

    Destination: 192.168.1.75

    VRF: default    Destination UDP Port 5640

    Source Interface loopback0 (20.2.0.2)

    DSCP 44

Flow exporter telemetryExp_1:

    Destination: 192.168.1.73

    VRF: default    Destination UDP Port 5640

    Source Interface loopback0 (20.2.0.2)

    DSCP 44

Flow exporter telemetryExp_2:

    Destination: 192.168.1.74

    VRF: default    Destination UDP Port 5640

    Source Interface loopback0 (20.2.0.2)

    DSCP 44

Feature Prio: Analytics

Flow Records

flow record telemetryRec

  match ip source address

  match ip destination address

  match ip protocol

  match transport source-port

  match transport destination-port

  collect counter bytes

  collect counter packets

spine21# show flow record

Flow record telemetryRec:

    No. of users: 1

    Template ID: 256

    Fields:

        match ip source address

        match ip destination address

        match ip protocol

        match transport source-port

        match transport destination-port

ACL Filters

ip access-list telemetryipv4acl

 

31 permit 97 131.1.101.0/27 131.1.201.0/24

30 permit 97 131.1.201.0/24 131.1.101.0/27

spine21# show flow filter

Filter telemetryFP:

    Ipv4 ACL: telemetryipv4acl

    Ipv6 ACL: telemetryipv6acl

Conclusion

There is a set of pre-requisite configurations for an NDFC managed or monitored network site before it can run Nexus Dashboard Insights properly. This white paper discusses the details of such required configuration. It can be used as a reference to get your NDFC managed or monitored network sites ready for Nexus Dashboard Insights. It also provides step-by-step guidance on how to add a network site to Nexus Dashboard Insights and how to enable Nexus Dashboard Insights services, such as bug scan, software telemetry, and flow telemetry functions.

Related Content

Nexus Dashboard 2.1.x User Guide

https://www.cisco.com/c/en/us/td/docs/dcn/nd/2x/user-guide/cisco-nexus-dashboard-user-guide-211.html

Nexus Dashboard Insights 6.0.x Deployment Guide

https://www.cisco.com/c/dam/en/us/td/docs/dcn/ndi/6x/deployment-guide/cisco-ndi-deployment-guide-release-602.pdf

Getting your Cisco DCNM Fabrics Ready for Nexus Dashboard Insights

https://www.cisco.com/c/en/us/td/docs/dcn/whitepapers/cisco-nexus-dashboard-fabric-controller-deployment-guide.html

Cisco Nexus Dashboard Fabric Controller 12

https://www.cisco.com/c/en/us/support/cloud-systems-management/nexus-dashboard-fabric-controller-12/model.html

Legal Information

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)

Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.

© 2022 Cisco Systems, Inc. All rights reserved.

Learn more