Cisco Nexus 9000 Series NX-OS Release Notes, Release 10.4(4)M

Available Languages

Download Options

  • PDF
    (880.6 KB)
    View with Adobe Reader on a variety of devices
Updated:October 19, 2024

Bias-Free Language

The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.

Available Languages

Download Options

  • PDF
    (880.6 KB)
    View with Adobe Reader on a variety of devices
Updated:October 19, 2024
 

 

Note:      The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product.

Introduction

This document describes the features, issues, and limitations of Cisco NX-OS software Release 10.4(4)M for use on the Cisco Nexus 9000 Series switches.

Date

Description

October 19, 2024

Release 10.4(4)M became available.

Software Features

There are no new software features introduced in Cisco NX-OS Release 10.4(4)M.

Hardware Features

The Cisco Nexus 92348GC-FX3 switch (N9K-C92348GC-FX3) is a 1-RU fixed-port, L2/L3 switch, designed for deployment in data centers. This switch has 48x 100M/1G BASE-T downlink ports, 4x 10/25 Gbps SFP28+ uplink ports, 2x 40/100 Gbps QSFP28+ uplink ports, and will deliver 696 Gbps of total bandwidth.

This switch includes these user-replaceable components.

    Fan modules (3) with the following airflow choices.

    Port-side intake airflow with burgundy coloring (NXA-SFAN-30CFM-PI)

    Port-side exhaust airflow with blue coloring (NXA-SFAN-30CFM-PE)

    Power supply modules (two—one for operations and one for redundancy [1+1]) with these choices (a mix of AC and DC power sources is supported. However, do not mix airflow directions):

    350-W AC power supply with port-side intake airflow (burgundy coloring) (NXA-PAC-350W-PI2)

    350-W AC power supply with port-side exhaust airflow (blue coloring) (NXA-PAC-350W-PE2)

    350-W PHV power supply with port-side intake airflow (burgundy coloring) (NXA-PHV-350W-PI)

    350-W PHV power supply with port-side exhaust airflow (blue coloring) (NXA-PHV-350W-PE)

    440-W DC power supply with port-side intake airflow (burgundy coloring) (NXA-PDC-440W-PI)

    440-W DC power supply with port-side exhaust airflow (blue coloring) (NXA-PDC-440W-PE)

For details on Cisco Nexus 92348GC-FX3 switch, see the Cisco Nexus NX-OS Mode Switch Hardware Installation Guide.

Unsupported Features on N9K-C92348GC-FX3

The following features are not supported on N9K-C92348GC-FX3 in Cisco NX-OS Release 10.4(4)M.

    MPLS

    VXLAN

    Analytics

    container-tracker

    Edge Virtual Bridge (evb)

    hardware-telemetry

    macsec

    nbm

    netflow

    ngoam

    nv overlay

    ptp

    security-group

    vmtracker

    vn-segment-vlan-based

    fcoe

    fcoe-npv

Release Image

In Cisco NX-OS Release 10.4(4)M, the following two 64-bit images are supported:

    The 64-bit Cisco NX-OS image filename with “nxos64-cs” as the prefix (for example, nxos64-cs.10.4.4.M.bin) is supported on all Cisco Nexus 9000 series switches except Cisco Nexus 9500 -R and -R2 switches and cards.

    The 64-bit Cisco NX-OS image filename with "nxos64-msll” as the prefix (for example, nxos64-msll.10.4.4.M.bin) is supported on Cisco Nexus 9000 Series -R and -R2 modular switches.

Note:      The 32-bit image is no longer supported.

Open Issues

Click the bug ID to access the Bug Search Tool and see additional information about the bug.

Bug ID

Headline

CSCwj58944

IPV6 RNH is not updated after ipv6 neighbors are cleared

CSCwk49611

Delayed linkup seen with 100G-SR4 on BV ports

CSCwk49982

NLB Source traffic failed to forward and gets flooded within nlb vlan

CSCwk76266

IGMP proxy reports not generated for L2TRM

CSCwm05315

reload of vPC peer causing transient loop of v6 traffic leading to incorrect Mac learn on VPC port

CSCwm40478

N9K-X9636C-RX: Traffic Punt with default route + uRPF

CSCwm49373

EVPN prefix fails to advertise when dup paths with same GWIPs are shared between RR via iBGP

CSCwm53422

VSH crashes when running show tech port manager

CSCwm55263

queue-limit dynamic 0 drops packets with minimal traffic on interface

CSCwm59420

VLAN Tag on GRE tunneled traffic is changed to Native VLAN for broadcast traffic on N9K

CSCwm63977

Unable to ping SVI with forwarding mode set to Warp

CSCwm72527

N9K-C93216TC-FX2:Uplink ports not link up with QSFP-H40G-CU3M

Resolved Issues

Click the bug ID to access the Bug Search Tool and see additional information about the bug.

Bug ID

Headline

CSCvz47575

Traceback TACACS-3-L3VM_LIBINIT Seen After AAA Failures

CSCvz72834

Cisco NX-OS Software DHCPv6 Relay Agent Denial of Service Vulnerability

CSCwc19270

N93108TC-FX3P in FEX mode displays incomplete port speed capabilities

CSCwd27446

DME CC for interfaces is failing resulting in telemetry data collection errors

CSCwh18936

Add Syslog for Incorrect Partitioning Detected

CSCwh77779

Cisco NX-OS Software Python Parser Escape Vulnerability

CSCwh77780

Cisco NX-OS Software Python Parser Escape Vulnerability

CSCwh77783

Cisco NX-OS Bash Privilege Escalation Vulnerability

CSCwh90029

Error fetching entries from hardware -- forwarding l2 table utilization instance all

CSCwi06810

MAC address table doesn't change via GARP during MAC move

CSCwi61233

High Info interrupts trigger throttle logic resulting DMA starvation and CPU busy

CSCwi71532

laser shuts down even break link is enabled post peer link shutdown

CSCwi85849

During PTP sync process, the switch updates the clock identity field but keeps sending unsynced time

CSCwi89071

Unable to see RBAC policy regex configuration in the running config.

CSCwj08246

NFP process reloaded unexpectedly after processing a config flow

CSCwj24274

N9K BGP route metric in RIB does not update after MED change when using Multipath

CSCwj27559

9.3(13): DME cc Failure seen for nxapi use-vrf management on FX3

CSCwj33002

N9K - Memory leak in tahusd process after EVPN uplink flap on FX3/GX/GX2/HX switch

CSCwj33847

Configuring Auto Neg on 25G 2.5M turns off fec, expected fec to be in fc-fec

CSCwj34504

"link debounce link-up time xx" config disappear after performing conf replace

CSCwj34531

Nexus 9k Switch Reloads Due To TAHUSD process

CSCwj37244

VXLAN - Traffic to IP x.x.137.2 is wrongly intercepted by OAM Sup ACL

CSCwj37487

problem in sub-interface creation when service-reflect interface config for mvrf nat

CSCwj42402

SR MPLS: ipfib process core after interface and router ISIS flap

CSCwj42765

10.4(3)F: Mcast traffic drop after running clear ip mroute * command on MVPN handoff device

CSCwj43716

10.4(3): NGOAM is getting service not responding error when peer nodes are not older version

CSCwj45146

SSH login triggers TACACS "temporary failure in name resolution" after upgrade

CSCwj49714

N9K: Traffic redirected to Ethernet1/1 if PACL has redirect option to a port missing XCVR

CSCwj50127

NXOS PSU shows shutdown though PSU is working

CSCwj50490

VXLAN EVPN GX - OV Table mis-programming causes BUM traffic to fail after VPC peer reload

CSCwj50611

N9k SR mNAT traffic may leave interface without NAT during an OIF change

CSCwj53632

feature hardware-telemetry causing Mac Moves: L2FM-4-L2FM_MAC_MOVE

CSCwj56953

10.5(1): in Underlay, explicit weight assignment to all available paths does not work

CSCwj57371

N9K VXLAN: A short loop occurs at the moment the peer-link is up after VPC peer restart

CSCwj59760

Yang Model get_diff "source" and "target" have Incorrect Information

CSCwj65063

Login with "admin" user with incorrect password allowed when "none" aaa authentication is configured

CSCwj67317

Multicast traffic dropping at Nexus 9500 FM-G due to ELAM VLAN_XLATE_MISS

CSCwj68588

9332-GX2B: DoM not supported error with 3rd party 100G AOC

CSCwj69012

DHCP Discover packets are being dropped with custom COPP policy on a purely L2 Nexus 9k

CSCwj69659

One way CDP neighborship seen between Nexus 9500 (L3) & Catalyst 3850(L2) when VLAN 1 is tagged.

CSCwj70267

N9K: ARP issue with Fabric Peering in VxLAN EVPN VPC set up

CSCwj73810

While adding IP unnumbered interface using Netconfic, an error generate

CSCwj77571

400G DR4 Finisar and Finisar+ on Nexus 9000 shows incorrect `show int transceiver` detail outputs

CSCwj78936

Config-sync fails to import running-config into Switch-Profile

CSCwj79046

N9K:duplicate "no errdisable detect cause acl-exception" in startup-config

CSCwj82709

"no mac address-table loop-detect nve port-down" cannot be configure on NXOS 10.2.5 or 10.4.3

CSCwj83432

[N9K] QSFP-100G-ZR4: Same value with Rx Power "High alarm" and "High warning" threshold

CSCwj84211

N9K-C9348GC-FXP - Ingress drops all packets with Bad Preamble tag

CSCwj88820

Nexus 93180YC-FX3 : L2 IGMP joins are dropped when L3 GRE tunnel is configured

CSCwj88901

Bad config applied to previous context if next config context contains syntax error in config file

CSCwj89859

N9K PBR IPv4 ACEs of icam will count without any PBR configuration.

CSCwj89920

Adding ITU channel config prevents port-channel creation on N9K switch.

CSCwj89973

N9K NX-OS 10.4(3) vman crash after upgrade, due to third-party transceiver being inserted

CSCwj90902

Telemetry suddenly stops working due to memory leak

CSCwj92155

Not able to remove the PIM RP-address config

CSCwj95850

N9K-C9348GC-FXP - Ingress drops all packets with Bad Preamble tag

CSCwk02394

SSH session/console pause indefinitely during configuring netflow

CSCwk02635

N9300 FHR may fail to create SG state for one of the sources sending traffic to same group

CSCwk03048

N9k TCAM Carving for e-racl must not be allowed for mpls extended ecmp

CSCwk03361

Unable to create a TACACS user due to the directory /var full with a power supply debug logfile.

CSCwk04005

VxLan: vPC fabric peering flap after time change

CSCwk04520

n9k: "DCBX No ACK in 100 PDU" seen after upgrade from 9.3.x to 10.3.4a

CSCwk07305

Packets with MPLS-SR label dropped on P routers

CSCwk11030

Storm control gets triggered when unplug/replug the cable of a port

CSCwk12313

Nexus generates VPC PKA packet with source IP not present on device

CSCwk15087

MST priority value get removed after changing vlan in a instance.

CSCwk27865

Archive feature doesn't work when $ is specified within password

CSCwk29697

KLM_pss installation delay seen (potentially leading to boot failure)

CSCwk30154

Stats for ACE matching different ether type not updated in MAC ACL

CSCwk32265

nxos/N9K-X9400-16W: Port 15 and 16 do not correctly forwarding traffic after reload

CSCwk34847

Nexus 9000 crash due to "tahusd" process crash @ tah_sdk_hea_aclqos_hex_print

CSCwk35857

Traffic blackholed after module or chassis reload EOR R linecards with custom MAC config

CSCwk36818

N9K - Memory leak in TAHUSD_MTRACK_TYPE_STATS_DMA_HDLR

CSCwk45686

Twamp not working in a server-N9k setup.

CSCwk49219

Type 2 route for RMACs with Next hop set to vIP address is not generated for IPv6 Fabric underlay

CSCwk49778

Getting an error when trying to enable log-neighbor-changes command

CSCwk50423

TLS Client Hello advertises curves not allowed by CC

CSCwk52635

Removing VLAN on one pair causing other pair to suspend all VLANs on port-channel in pvlan trunk

CSCwk56902

Configuring 'udld diable' thru configure-replace it returns an empty patch and nothing configuring

CSCwk59961

MMODE config failure with large range of interface configs

CSCwk61156

QinQ traffic disrupted afer removing "switchport trunk allow-multi-tag" command

CSCwk61235

Critical CVE in component openssh. Upgrade to latest version.

CSCwk64527

10.5(1): Permission denied error seen on show interface | json on network-operator other than admin

CSCwk69444

Rapid memory leak in securityd and component(libpython3.8.so.1.0)

CSCwk70281

NXOS: port-security mac-address config accepted but not applied

CSCwk72984

10.5(1): N9K-X9400-8D: 4x100g DR4 HBO/SBO, all 4 lanes are not up on LEM reload/power cycle

CSCwk73210

 private-vlans suspended on vpc primary side after switch bootup

CSCwk74555

host-proxy configurations doesnt work properly after trigger of pim restart

CSCwk76333

N9K traffic interrupt due to delayed phy port down when admin shutdown E1-48 PO member port

CSCwk77003

N9K delay forwarding of IGMP proxy v3 report when "ip igmp snooping v3-report-suppression" enabled

CSCwk78700

BGP does not pass Tunnel Encapsulation attribute to Cloudsec from the best path in BRIB

CSCwk82500

Nexus SNMP Transceiver Polling causes SNMPD process crash

CSCwk84750

Memory Leak on snmpd process

CSCwk88760

static igmp/mld snooping not work when flexlink UP/Standby state changed

CSCwk99030

GX/GX2 platforms leak ucast PIM register messages to s/w in switching path

CSCwm00544

Nexus N9K-X9716D-GX Failed 100G to 400G Conversion

CSCwm04251

Parent Missing for OID 1.3.6.1.2.1.47.1.1.1.1.4 in N9K-C93600CD-GX

CSCwm05051

QinQ inner-vlan stripped egress with system dot1q-tunnel transit

CSCwm05197

DHCP packet not able to traverse a n9k with ip address dhcp on a svi

CSCwm05521

TAHUSD crash with "show" commands on BearValley ports

CSCwm06182

QDD-2X100-SR4-S - Breakout interfaces lanes shutdown when sibling interfaces are shutdown.

CSCwm06460

Unable to remove "fabric forwarding mode anycast-gateway" from a L3VNI

CSCwm11106

clean up traces in "show hardware internal tah event-history xcvr <port>"

CSCwm11587

VPC fabric peer sends TCP packets with DSCP value 0

CSCwm11668

Running "show logging onboard card-boot-history" and similar commands on FX3 in fex mode crashes FEX

CSCwm12994

'clear hardware internal forwarding adjacency statistics default-route' command throws error

CSCwm13904

Unable to install nxapi certificate

CSCwm24449

Missprogramming Infra-VLAN is redirecting traffic to CPU on Nexus 9K.

CSCwm27313

Multicast traffic gets delayed to forward upon receiving v3 proxy report

CSCwm29927

NTP configuration with use-vrf management fails with FQDN

CSCwm30659

Twampv6 not working in 10.2(4) release

CSCwm35057

In 9k vpc, remove and readd peer-gateway on both sides results in stale sdk-l2 entry

CSCwm37332

PTP out of sync on a breakout interface

CSCwm39756

L2 multicast traffic is not forwarded to vPC Fabric peer switch.

CSCwm45137

Observing tahusd crash & box reload while running sh tech all post upgrading SSD firmware

CSCwm47657

Nexus responds with timeout instead of "Bad context specified" when SNMP query uses context

CSCwm49356

IGMP flooding through TAP interfaces

CSCwm50407

Host Route learning is failing when vPC peer switch is down for orphan host

CSCwm60250

Memory Leak in l2fm Process Shared Library libutils.so on Nexus 9k Switches

CSCwm68391

N9K crashes with IPFIB Segmentation Fault when processing iBGP Updates with unreachable NHs

CSCwm72260

Implement recovery mechanism for traffic going over same incoming interface

CSCwm77153

Nexus 9500 - ethport-channel core with ascii reload

General/Known Issues

Click the bug ID to access the Bug Sefarch Tool and see additional information about the bug.

Bug ID

Description

CSCwi95977

DME CC failure for mutiisite virtual rmac

CSCwi95768

Loopback Ping is not working after enabling MPLS LDP at Interface 

CSCwh36396

Third Party 40G SWDM4 transceiver may take between 40-60 secs to link up

CSCwh88451

URIB crashed on urib_chlist_segv_handler after restarting bgp and urib together

CSCwi57646

ESG_SGACL: Source of MAC detail is not seen in json output of MAC table

CSCwi87175

slight drop in L2 multicast performance in pualaner switch

CSCwi24238

With NDFC/auto-config, VPC peer-link stays down on disable 'feature tunnel-encryption'

CSCvt37624

'The BGP instance is not in expected state' after quick bgp unconfig / reconfig with 700K ipv4 pfx

CSCwi22304

TTL is not decremented for decap L3 VPN traffic on N9K-C9800.

CSCwh44244

DME inconsistency in sys/mplsta-[eth1/7/1] object after some CLI sequence

Device Hardware

The following tables list the Cisco Nexus 9000 Series hardware that Cisco NX-OS Release 10.4(4)M supports. For additional information about the supported hardware, see the Hardware Installation Guide for your Cisco Nexus 9000 Series device.

Table 1.        Cisco Nexus 9800 Switches

Product ID

Description

N9K-C9808

16-RU modular switch with slots for up to 8 Line Cards in addition to 2 supervisors, 8 fabric modules, 4 fan trays, and 3 power trays.

N9K-C9804

10-RU modular switch with slots for up to 4 Line Cards in addition to 2 supervisors, 8 fabric modules, 4 fan trays, and 2 power trays.

Table 2.        Cisco Nexus 9800 Series Line Cards

Product ID

Description

N9K-X9836DM-A

Cisco Nexus 9800 36-port 400G QSFP-DD Line Card with MACsec.

N9K-X98900CD-A

Cisco Nexus 9800 14-port 400G QSFP-DD + 34-port 100G QSFP28 Line Card.

Table 3.        Cisco Nexus 9800 Series Fabric Modules

Product ID

Description

N9K-C9808-FM-A

Cisco Nexus 9800 Fabric Module for 8-slot Chassis

N9K-C9804-FM-A

Cisco Nexus 9800 Fabric Module for 4-slot Chassis

Table 4.        Cisco Nexus 9800 Supervisor Module

Product ID

Description

N9K-C9800-SUP-A

Cisco Nexus 9800 Platform Supervisor Module

Table 5.        Cisco Nexus 9800 Fans and Fan Trays

Product ID

Description

N9K-C9808-FAN-A

Cisco Nexus 9800 8-slot chassis fan tray (1st Generation)

N9K-C9804-FAN-A

Cisco Nexus 9800 4-slot chassis fan tray (1st Generation)

Table 6.        Cisco Nexus 9800 Power Supplies

Product ID

Description

NXK-HV6.3KW20A-A

Cisco Nexus 9800 6,300W 20A AC and HV Power Supply

Table 7.        Cisco Nexus 9500 Switches

Product ID

Description

N9K-C9504

7-RU modular switch with slots for up to 4 Line Cards in addition to two supervisors, 2 system controllers, 3–6 fabric modules, 3 fan trays, and up to 4 power supplies.

N9K-C9508

13-RU modular switch with slots for up to 8 Line Cards in addition to two supervisors, 2 system controllers, 3–6 fabric modules, 3 fan trays, and up to 8 power supplies.

N9K-C9516

21-RU modular switch with slots for up to 16 Line Cards in addition to two supervisors, 2 system controllers, 3–6 fabric modules, 3 fan trays, and up to 10 power supplies.

Table 8.        Cisco Nexus 9500 Cloud Scale Line Cards

Product ID

Description

Maximum Quantity

Cisco Nexus 9504

Cisco Nexus 9508

Cisco Nexus 9516

N9K-X9716D-GX

Cisco Nexus 9500 16-port 400G QSFP-DD Line Card

4

8

N/A

N9K-X9736C-FX

Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

16

N9K-X9788TC-FX

Cisco Nexus 9500 48-port 1/10-G BASE-T Ethernet and 4-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

16

N9K-X97160YC-EX

Cisco Nexus 9500 48-port 10/25-Gigabit Ethernet SFP28 and 4-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

16

N9K-X9732C-FX

Cisco Nexus 9500 32-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

16

N9K-X9732C-EX

Cisco Nexus 9500 32-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

16

N9K-X9736C-EX

Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

16

Table 9.        Cisco Nexus 9500 R-Series Line Cards

Product ID

Description

Maximum Quantity

Cisco Nexus 9504

Cisco Nexus 9508

N9K-X9636C-R

Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

N9K-X9636C-RX

Cisco Nexus 9500 36-port 40/100 Gigabit Ethernet QSFP28 Line Card

4

8

N9K-X9636Q-R

Cisco Nexus 9500 36-port 40-Gigabit Ethernet QSFP Line Card

4

8

N9K-X96136YC-R

Cisco Nexus 9500 16-port 1/10 Gigabit, 32-port 10/25 Gigabit, and 4-port 40/100 Gigabit Ethernet Line Card

4

8

N9K-X9624D-R2

Cisco Nexus 9500 24-port 400-Gigabit QDD Line Card

Not supported

8

Table 10.     Cisco Nexus 9500 Cloud Scale Fabric Modules

Product ID

Description

Minimum

Maximum

N9K-C9504-FM-E

Cisco Nexus 9504 100-Gigabit cloud scale fabric module

4

5

N9K-C9504-FM-G

Cisco Nexus 9500 4-slot 1.6Tbps cloud scale fabric module

4

5

N9K-C9508-FM-E

Cisco Nexus 9508 100-Gigabit cloud scale fabric module

4

5

N9K-C9508-FM-E2

Cisco Nexus 9508 100-Gigabit cloud scale fabric module

4

5

N9K-C9508-FM-G

Cisco Nexus 9500 8-slot 1.6Tbps cloud-scale fabric module

4

5

N9K-C9516-FM-E2

Cisco Nexus 9516 100-Gigabit cloud scale fabric module

4

5

Table 11.     Cisco Nexus 9500 R-Series Fabric Modules

Product ID

Description

Minimum

Maximum

N9K-C9504-FM-R

Cisco Nexus 9504 100-Gigabit R-Series fabric module

4

6

N9K-C9508-FM-R

Cisco Nexus 9508 100-Gigabit R-Series fabric module

4

6

N9K-C9508-FM-R2

Cisco Nexus 9508 400-Gigabit R-Series fabric module

4

6

Table 12.     Cisco Nexus 9500 Supervisor Modules

Supervisor

Description

Maximum

N9K-SUP-A

1.8-GHz supervisor module with 4 cores, 4 threads, and 16 GB of memory

2

N9K-SUP-A+

1.8-GHz supervisor module with 4 cores, 8 threads, and 16 GB of memory

2

N9K-SUP-B

2.2-GHz supervisor module with 6 cores, 12 threads, and 24 GB of memory

2

N9K-SUP-B+

1.9-GHz supervisor module with 6 cores, 12 threads, and 32 GB of memory

2

Note:      N9K-SUP-A and N9K-SUP-A+ are not supported on Cisco Nexus 9504 and 9508 switches with -R and -R2 Line Cards.

Table 13.     Cisco Nexus 9500 System Controller

Product ID

Description

Quantity

N9K-SC-A

Cisco Nexus 9500 Platform System Controller Module

2

Table 14.     Cisco Nexus 9500 Fans and Fan Trays

Product ID

Description

Quantity

N9K-C9504-FAN

Fan tray for 4-slot modular chassis

3

N9K-C9504-FAN2

Fan tray that supports the Cisco N9K-C9504-FM-G fabric module

3

N9K-C9508-FAN

Fan tray for 8-slot modular chassis

3

N9K-C9508-FAN2

Fan tray that supports the Cisco N9K-C9508-FM-G fabric module

3

N9K-C9516-FAN

Fan tray for 16-slot modular chassis

3

Table 15.     Cisco Nexus 9500 Fabric Module Blanks with Power Connector

Product ID

Description

Minimum

Maximum

N9K-C9504-FAN-PWR

Cisco Nexus 9500 4-slot chassis 400G cloud scale fan tray power connector

1

2

N9K-C9508-FAN-PWR

Cisco Nexus 9500 4-slot chassis 400G cloud scale fan tray power connector

1

2

Table 16.     Cisco Nexus 9500 Power Supplies

Product ID

Description

Quantity

Cisco Nexus Switches

N9K-PAC-3000W-B

3-KW AC power supply

Up to 4

Up to 8

Up to 10

Cisco Nexus 9504

Cisco Nexus 9508

Cisco Nexus 9516

N9K-PDC-3000W-B

3-KW DC power supply

Up to 4

Up to 8

Up to 10

Cisco Nexus 9504

Cisco Nexus 9508

Cisco Nexus 9516

N9K-PUV-3000W-B

3-KW Universal AC/DC power supply

Up to 4

Up to 8

Up to 10

Cisco Nexus 9504

Cisco Nexus 9508

Cisco Nexus 9516

N9K-PUV2-3000W-B

3.15-KW Dual Input Universal AC/DC Power Supply

Up to 4

Up to 8

Up to 10

Cisco Nexus 9504

Cisco Nexus 9508

Cisco Nexus 9516

Table 17.     Cisco Nexus 9400 Switches

Product ID

Description

N9K-C9408

4-RU, 8-slot centralized modular chassis switch, which is configurable with up to 128 200-Gigabit QSFP56 (256 100 Gigabit by breakout) ports or 64 400-Gigabit ports.

N9K-C9400-SUP-A

Cisco Nexus 9400 Supervisor Card

N9K-C9400-SW-GX2A

Cisco Nexus 9400 25.6Tbps Switch Card

N9K-X9400-8D

Cisco Nexus 9400 8p 400G QSFP-DD LEM

N9K-X9400-16W

Cisco Nexus 9400 16p 200G QSFP56 LEM

N9K-X9400-22L

Cisco Nexus 9400 LEM with 22 10G/25G/50G ports.

Table 18.     Cisco Nexus 9200 and 9300 Switches

Cisco Nexus Switch

Description

N9K-C92348GC-X

The Cisco Nexus 92348GC-X switch (N9K-C92348GC-X) is a 1-RU switch that supports 696 Gbps of bandwidth and over 250 mpps.

The 1GBASE-T downlink ports on the 92348GC-X can be configured to work as 100 Mbps, 1-Gbps ports.

The 4 ports of SFP28 can be configured as 1/10/25-Gbps and the two-ports of QSFP28 can be configured as 40- and 100-Gbps ports.

The Cisco Nexus 92348GC-X is ideal for Big Data customers that require a Gigabit Ethernet ToR switch with local switching.

N9K-C93400LD-H1

1-RU fixed-port, L2/L3 switch with 48 50G SFP56 ports and 4 400G QSFP-DD uplink ports.

N9K-C93108TC-FX3

1 RU fixed-port switch Forty-eight 100M/1G/10GBASE-T ports (ports 1–48), Six 40/100-Gigabit ports QSFP28 (ports 49–54), Two management ports (one 10/100/1000BASE-T port and one SFP port), One console port (RS-232), and one USB port.

N9K-C9332D-H2R

1-RU fixed-port switch with 400-Gigabit QSFP-DD ports (32), 10-Gigabit SFP+ ports (2), Management ports (one 10/100/1000BASE-T port and one SFP port), console port (RS-232), and USB port.

N9K-C9348GC-FX3

1 RU fixed-port switch 48 10/100/1000M copper RJ-45 downlink ports, 4 10-/25G SFP28 uplink ports, and 2 40-/100G QSFP28 uplink ports.

N9K-C9348GC-FX3PH

1-RU fixed-port switch 40 10M/100M/1G copper RJ-45 downlink ports that support PoE/PoE+/PoE++ and 8 10M/100M copper RJ-45 downlink ports that support PoE/PoE+/PoE++, 4 10-/25G SFP28 uplink ports, and 2 40-/100G QSFP28 uplink ports.

N9K-C93180YC-FX3H

1-RU fixed-port switch with 24 100M/1/10/25-Gigabit Ethernet SFP28 ports (ports 1–24), 6 10/25/40/50/100-Gigabit QSFP28 ports (ports 49–54), One management port (one 10/100/1000BASE-T port), and One console port (RS-232)

N9K-C9316D-GX

1-RU switch with 16x400/100/40-Gbps ports.

N9K-C9364C-GX

2-RU fixed-port switch with 64 100-Gigabit SFP28 ports.

N9K-C93600CD-GX

1-RU fixed-port switch with 28 10/40/100-Gigabit QSFP28 ports (ports 1–28), 8 10/40/100/400-Gigabit QSFP-DD ports (ports 29–36)

N9K-C9364C

2-RU Top-of-Rack switch with 64 40-/100-Gigabit QSFP28 ports and 2 1-/10-Gigabit SFP+ ports.

  Ports 1 to 64 support 40/100-Gigabit speeds.
  Ports 49–64 support MACsec encryption.
  Ports 651–64and66 support 1/10 Gigabit speeds.

N9K-C9364C-H1

2-RU fixed-port switch with 64 100G SFP28 ports.

N9K-C9332C

1-RU fixed switch with 32 40/100-Gigabit QSFP28 ports and 2 fixed 1/10-Gigabit SFP+ ports.

N9K-C9332D-GX2B

1-Rack-unit (1-RU) spine switch with 32p 400/100-Gbps QSFP-DD ports and 2p 1/10 SFP+ ports.

N9K-C9348D-GX2A

48p 40/100/400-Gigabit QSFP-DD ports and 2p 1/10G/10G SFP+ ports

N9K-C9364D-GX2A

64p 400/100-Gigabit QSFP-DD ports and 2p 1/10 SFP+ ports

N9K-C93180YC-FX3

48 1/10/25 Gigabit Ethernet SFP28 ports (ports 1–48)

6 10/25/40/50/100-Gigabit QSFP28 ports (ports 49–54)

N9K-C93180YC-FX3S

48 1/10/25 Gigabit Ethernet SFP28 ports (ports 1–48)

6 10/25/40/50/100-Gigabit QSFP28 ports (ports 49–54)

N9K-C9336C-FX2-E

1-RU switch with 36 40-/100-Gb QSFP28 ports

N9K-C9336C-FX2

1-RU switch with 36 40-/100-Gb Ethernet QSFP28 ports

N9K-C93360YC-FX2

2-RU switch with 96 10-/25-Gigabit SFP28 ports and 12 40/100-Gigabit QSFP28 ports

N9K-C93240YC-FX2

1.2-RU Top-of-Rack switch with 48 10-/25-Gigabit SFP28 fiber ports and 12 40-/100-Gigabit Ethernet QSFP28 ports.

N9K-C93216TC-FX2

2-RU switch with 96 100M/1G/10G RJ-45 ports, 12 40/100-Gigabit QSFP28 ports, 2 management ports (one RJ-45 and one SFP port), 1 console port, and 1 USB port.

N9K-C93180YC-FX

1-RU Top-of-Rack switch with 10-/25-/32-Gigabit Ethernet/FC ports and 6 40-/100-Gigabit QSFP28 ports. You can configure the 48 ports as 1/10/25-Gigabit Ethernet ports or as FCoE ports or as 8-/16-/32-Gigabit Fibre Channel ports.

N9K-C93180YC-FX-24

1 RU 24 1/10/25-Gigabit Ethernet SFP28 front panel ports and 6 fixed 40/100-Gigabit Ethernet QSFP28 spine-facing ports. The SFP28 ports support 1-, 10-, and 25-Gigabit Ethernet connections and 8-, 16-, and 32-Gigabit Fibre Channel connections.

N9K-C93108TC-FX

1-RU Top-of-Rack switch with 48 100M/1/10GBASE-T (copper) ports and 6 40-/100-Gigabit QSFP28 ports

N9K-C93108TC-FX-24

1 RU 24 1/10GBASE-T (copper) front panel ports and 6 fixed 40/100-Gigabit Ethernet QSFP28 spine-facing ports.

N9K-C93108TC-FX3P

1-RU fixed-port switch with 48 100M/1/2.5/5/10GBASE-T ports and 6 40-/100-Gigabit QSFP28 ports

N9K-C9348GC-FXP0F[1]

Cisco Nexus 9300 with 48p 100M/1 G, 4p 10/25 G SFP+ and 2p 100 G QSFP

Table 19.     Cisco Nexus 9200 and 9300 Fans and Fan Trays

Product ID

Description

Quantity

Cisco Nexus Switches

NXA-SFAN-30CFM-PE

Fan module with port-side exhaust airflow (blue coloring)

3

9348GC-FX3

NXA-SFAN-30CFM-PI

Fan module with port-side intake airflow (burgundy coloring)

3

9348GC-FX3

NXA-SFAN-30CFM-PE

Fan module with port-side exhaust airflow (blue coloring)

3

9348GC-FX3PH

NXA-SFAN-30CFM-PI

Fan module with port-side intake airflow (burgundy coloring)

3

9348GC-FX3PH

NXA-SFAN-35CFM-PI

Fan module with port-side intake airflow (burgundy coloring)

6

 

5

 

4

9332D-H2R

 

93400LD-H1

 

93108TC-FX3

NXA-SFAN-35CFM-PE

Fan module with port-side exhaust airflow (blue coloring)

6

 

5

 

4

9332D-GX2B

 

93400LD-H1

 

93108TC-FX3

NXA-SFAN-35CFM-PI

Fan module with port-side intake airflow (burgundy coloring)

6

9332D-GX2B

NXA-FAN-160CFM-PE

Fan module with port-side exhaust airflow (blue coloring)

3

9364C [1F[2]]
93360YC-FX2

NXA-FAN-160CFM-PI

Fan module with port-side intake airflow (burgundy coloring)

3

9364C [1]

93360YC-FX2

NXA-FAN-160CFM2-PE

Fan module with port-side exhaust airflow (blue coloring)

4

9364C-GX

NXA-FAN-160CFM2-PI

Fan module with port-side intake airflow (burgundy coloring)

4

9364C-GX

NXA-FAN-30CFM-B

Fan module with port-side intake airflow (burgundy coloring)

3

93108TC-FX [1]
93180YC-FX [1]
9348GC-FXP [1]

NXA-FAN-30CFM-F

Fan module with port-side exhaust airflow (blue coloring)

3

93108TC-FX [1]
93180YC-FX [1]
9348GC-FXP

NXA-FAN-35CFM-PE

Fan module with port-side exhaust airflow (blue coloring)

4

 

 

 

 

 

 

6

92300YC [1]
9332C [1]
93180YC-FX3S [2F[3]]
93180YC-FX3
93108TC-FX3P
93180YC-FX3H

9336C-FX2-E
9316D-GX
93600CD-GX

 

NXA-FAN-35CFM-PI

Fan module with port-side intake airflow (burgundy coloring)

 

 

 

 

 

 

 

Fan module with port-side exhaust airflow (blue coloring)

4

 

 

 

 

6

 

 

6

92300YC [1]
9332C [1]
93180YC-FX3S [2]
93180YC-FX3
93108TC-FX3P
93180YC-FX3H

9316D-GX
93600CD-GX

 

9336C-FX2-E

NXA-FAN-65CFM-PE

Fan module with port-side exhaust airflow (blue coloring)

3

93240YC-FX2 [1]
9336C-FX2 [1]

NXA-FAN-65CFM-PI

Fan module with port-side exhaust airflow (burgundy coloring)

3

93240YC-FX2
9336C-FX2 [1]

Table 20.     Cisco Nexus 9200 and 9300 Power Supplies

Product ID

Description

Quantity

Cisco Nexus Switches

NXA-PDC-715W-PI

715-W DC power supply with port-side intake airflow (blue coloring)

2

93108TC-FX3P

NXA-PDC-440W-PE

440-W DC power supply with port-side exhaust airflow (blue coloring)

2

9348GC-FX3
9348GC-FX3PH

NXA-PDC-440W-PI

440-W DC power supply with port-side intake airflow (burgundy coloring)

2

9348GC-FX3

9348GC-FX3PH

NXA-PHV-350W-PE

350-W AC power supply with port-side exhaust airflow (blue coloring)

2

9348GC-FX3
9348GC-FX3PH

NXA-PHV-350W-PI

350-W AC power supply with port-side intake airflow (burgundy coloring)

2

9348GC-FX3

9348GC-FX3PH

NXA-PAC-350W-PE2

350-W AC power supply with port-side exhaust airflow (blue coloring)

2

9348GC-FX3
9348GC-FX3PH

NXA-PAC-350W-PI2

350-W AC power supply with port-side intake airflow (burgundy coloring)

2

9348GC-FX3

9348GC-FX3PH

NXA-PAC-1900W-PE

1900-W AC power supply with port-side exhaust airflow (blue coloring)

2

9348GC-FX3

9348GC-FX3PH

NXA-PAC-1900W-PI

1900-W AC power supply with port-side intake airflow (burgundy coloring)

2

9348GC-FX3

9348GC-FX3PH

NXA-PHV-2KW-PI

2000-W HVDC power supply with port-side intake airflow (burgundy coloring)

2

9332D-H2R

93400LD-H1

NXA-PAC-1500W-PE

1500-W AC power supply with port-side exhaust airflow (blue coloring)

2

9332D-GX2B

NXA-PAC-1500W-PI

1500-W AC power supply with port-side intake airflow (burgundy coloring)

2

9332D-GX2B

NXA-PAC-500W-PE

500-W AC power supply with port-side exhaust airflow (blue coloring)

2

93180YC-FX
93108TC-FX3

NXA-PAC-500W-PI

500-W AC power supply with port-side intake airflow (burgundy coloring)

2

93180YC-FX
93108TC-FX3

NXA-PAC-650W-PE

650-W AC power supply with port-side exhaust (blue coloring)

2

92300YC
93180YC-FX3S
93180YC-FX3

93180YC-FX3H

NXA-PAC-650W-PI

650-W AC power supply with port-side intake (burgundy coloring)

2

92300YC
93180YC-FX3S
93180YC-FX3

93180YC-FX3H

NXA-PAC-750W-PE

750-W AC power supply with port-side exhaust airflow (blue coloring) 1

2

9336C-FX2
9336C-FX2-E
9332C
93240YC-FX2

NXA-PAC-750W-PI

750-W AC power supply with port-side intake airflow (burgundy coloring) 1

2

9336C-FX2
9336C-FX2-E
9332C
93240YC-FX2

NXA-PAC-1100W-PE2

1100-W AC power supply with port-side exhaust airflow (blue coloring)

2

93240YC-FX2
9332C
9316D-GX
9336C-FX2
9336C-FX2-E
93600CD-GX

NXA-PAC-1100W-PI2

1100-W AC power supply with port-side intake airflow (burgundy coloring)

2

93240YC-FX2
9332C
9316D-GX
9336C-FX2
9336C-FX2-E
93600CD-GX

NXA-PAC-1100W-PI

Cisco Nexus 9000 PoE 1100W AC PS, port-side intake

2

93108TC-FX3P

NXA-PAC-1100W-PE

Cisco Nexus 9000 PoE 1100W AC PS, port-side exhaust

2

93108TC-FX3P

NXA-PAC-1900W-PI

Cisco Nexus 9000 PoE 1900W AC PS, port-side intake

2

93108TC-FX3P

NXA-PAC-1200W-PE

1200-W AC power supply with port-side exhaust airflow (blue coloring)

2

93360YC-FX2
9364C

NXA-PAC-1200W-PI

1200-W AC power supply with port-side intake airflow (burgundy coloring)

2

93360YC-FX2
9364C

NXA-PAC-1400W-PE

1400-W AC power supply with port-side exhaust airflow (blue coloring)

2

93400LD-H1

NXA-PAC-1400W-PI

1400-W AC power supply with port-side intake airflow (burgundy coloring)

2

93400LD-H1

N9K-PUV-1200W

1200-W Universal AC/DC power supply with bidirectional airflow (white coloring)

2

92300YC
93108TC-FX
93360YC-FX2
93180YC-FX3S
93180YC-FX
9364C
93108TC-FX3

NXA-PDC-930W-PE

930-W DC power supply with port-side exhaust airflow (blue coloring)

2

93360YC-FX2
93180YC-FX3S
93180YC-FX
9364C
93180YC-FX3H
93108TC-FX3

NXA-PDC-930W-PI

930-W DC power supply with port-side intake airflow (burgundy coloring)

2

93360YC-FX2
93180YC-FX3S
93180YC-FX
9364C
93180YC-FX3H
93108TC-FX3

NXA-PDC-1100W-PE

1100-W DC power supply with port-side exhaust airflow (blue coloring)

2

93240YC-FX2
93600CD-GX
9316D-GX
9332C
9336C-FX2
9336C-FX2-E

NXA-PDC-1100W-PI

1100-W DC power supply with port-side intake airflow (burgundy coloring)

2

93240YC-FX2
93600CD-GX
9316D-GX
9332C
9336C-FX2
9336C-FX2-E

NXA-PHV-1100W-PE

1100-W AC power supply with port-side exhaust airflow (blue coloring)

2

93240YC-FX2
9336C-FX2

NXA-PHV-1100W-PI

1100-W AC power supply with port-side intake airflow (burgundy coloring)

2

93240YC-FX2
9336C-FX2

NXA-PAC-2KW-PE

2000-W AC power supply with port-side exhaust airflow (blue coloring)

2

9364C-GX

 

NXA-PAC-2KW-PI

2000-W AC power supply with port-side intake airflow (burgundy coloring)

2

9364C-GX
9332D-H2R

NXA-PDC-2KW-PE

2000-W DC power supply with port-side exhaust airflow (blue coloring

2

9364C-GX

93400LD-H1

NXA-PDC-2KW-PI

2000-W DC power supply with port-side intake airflow (burgundy coloring)

2

9364C-GX

9332D-H2R

93400LD-H1

N2200-PAC-400W

400-W AC power supply with port-side exhaust airflow (blue coloring)

2

92348GC-X

N2200-PAC-400W-B

400-W AC power supply with port-side intake airflow (burgundy coloring)

2

92348GC-X

N2200-PDC-350W-B

350-W DC power supply with port-side intake airflow

2

92348GC-X

N2200-PDC-400W

400-W DC power supply with port-side exhaust airflow (blue coloring)

2

92348GC-X

Compatibility Information

Fabric Module and Line Card compatibility details are listed below:

Table 21.     Cisco Nexus 9500 Cloud Scale Line Cards

Product ID

N9K-C9504-FM-G

N9K-C9508-FM-G

N9K-C9504-FM-E

N9K-C9508-FM-E

N9K-C9508-FM-E2

N9K-C9516-FM-E2

N9K-X9716D-GX

4

4

No

No

No

No

N9K-X9736C-FX

5

5

5

5

5

5

N9K-X97160YC-EX

4

4

4

4

4

4

N9K-X9788TC-FX

4

4

4

4

4

4

N9K-X9732C-EX

4

4

4

4

4

4

N9K-X9732C-FX

4

5 (n+1 redundancy)

4

5 (n+1 redundancy)

4

5 (n+1 redundancy)

4

5 (n+1 redundancy)

4

5 (n+1 redundancy)

4

5 (n+1 redundancy)

Table 22.     Cisco Nexus 9500 R-Series Line Cards

Product ID

N9K-C9504-FM-R

N9K-C9508-FM-R

N9K-X9636C-RX

6

6

N9K-X9636Q-R

4

6 (n+2 redundancy)

4

6 (n+2 redundancy)

N9K-X9636C-R

5

6 (n+1 redundancy)

5

6 (n+1 redundancy)

N9K-X96136YC-R

6

6

Table 23.     Cisco Nexus 9500 R2-Series Line Cards

Product ID

N9K-C9508-FM-R2

N9K-X9624D-R2

6

Optics

For information about transceivers and cables supported on a switch, see the Transceiver Module (TMG) Compatibility Matrix. For the transceiver specifications and installation information, see the Install and Upgrade Guides.

Cisco Nexus Dashboard Insights for Data Center

Cisco NX-OS Release 10.4(4)M supports the Cisco Nexus Dashboard Insights on Cisco Nexus 9300-FX, 9300-FX2, 9300-FX3, 9300-GX, 9300-GX2, 9400, and 9800 platform switches and 9500 platform switches with -EX/FX/GX Line Cards. See the Cisco Nexus Insights documentation.

Upgrade and Downgrade

To perform a software upgrade or downgrade, follow the instructions in the Cisco Nexus 9000 Series NX-OS Software Upgrade and Downgrade Guide, Release 10.4(x). For information about an In Service Software Upgrade (ISSU), see the Cisco NX-OS ISSU Support Matrix.

Related Content

Document Title

Description

Cisco Nexus 9000 Series Switches

Cisco Nexus 9000 Series Switches documentation

Cisco NX-OS Software Strategy and Lifecycle Guide

Cisco NX-OS Software Release and Image-naming Convention

Cisco Nexus 3000 and 9000 Series NXAPI REST SDK User Guide and API Reference

Cisco Nexus 3000 and 9000 Series NX-NX-API REST SDK User Guide and API Reference

·       Cisco NX-OS Licensing Guide

·       Cisco Nexus 9000 and 3000 Series NX-OS Switch License Navigator

·       Cisco Nexus Smart Licensing Using Policy User Guide

Licensing Information

Note:      When you downgrade from Cisco NX-OS Release 10.4(4)M to an earlier release, the features that use the ACI+NX-OS Essentials, Advantage, and add-on licenses or the Hardware Streaming Telemetry license continue to work in honor mode in the downgraded version. In addition, the output of the show license usage command continues to include entries for these unsupported licenses.

Cisco Nexus 9000 Series NX-OS Software Upgrade and Downgrade Guide

Cisco Nexus 9000 Series Software Upgrade and Downgrade Guide, Release 10.4(x)

Cisco Nexus 9000 Series FPGA/EPLD Upgrade Release Notes

Cisco Nexus 9000 Series FPGA/EPLD Upgrade Release Notes, Release 10.4(4)M

https://cisco.github.io/cisco-mibs/supportlists/nexus9000/Nexus9000MIBSupportList.html

Cisco NX-OS Supported MIBs

Cisco Nexus 9000 Series Switch FEX Support Matrix

Supported FEX modules

Cisco Nexus 9000 Series Hardware Installation Guides

Cisco Nexus 9000 Series Hardware Installation Guides

Documentation Feedback

To provide technical feedback on this document, or to report an error or omission, please send your comments to nexus9k-docfeedback@cisco.com. We appreciate your feedback.

Legal Information

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: https://www.cisco.com/c/en/us/about/legal/trademarks.html. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1721R)

Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.

© 2024 Cisco Systems, Inc. All rights reserved.



[1] For N9K-C9348GC-FXP the PSU SPROM is not readable when the PSU is not connected. The model displays as "UNKNOWN" and status of the module displays as "shutdown."
[2] For specific fan speeds see the Overview section of the Hardware Installation Guide.
[3] This switch runs with +1 redundancy mode so that if one fan fails, the switch can sustain operation. But if a second fan fails, this switch is not designed to sustain operation. Hence before waiting for the major threshold temperature to be hit, the switch will power down due to entering the fan policy trigger command.

Learn more