Cisco Nexus Dashboard Fabric Controller Verified Scalability
Verified Scale Limits for Release 12.0.1a
This section provides verified scalability values for various deployment types for Cisco Nexus Dashboard Fabric Controller, Release 12.0.1a.
The values are validated on testbeds that are enabled with a reasonable number of features and aren’t theoretical system limits for Cisco Nexus Dashboard Fabric Controller software or Cisco Nexus/MDS switch hardware and software. When you try to achieve maximum scalability by scaling multiple features at the same time, results might differ from the values that are listed here.
Nexus Dashboard Server Resource (CPU/Memory) Requirements
Deployment Type | Node Type | CPUs | Memory | Storage (Throughput: 40-50MB/s) |
---|---|---|---|---|
Fabric Discovery | Virtual Node (vND) – app OVA |
16vCPUs |
64GB |
550GB SSD |
Physical Node (pND) (PID: SE-NODE-G2) |
2x 10-core 2.2G Intel Xeon Silver CPU |
256 GB of RAM |
4x 2.4TB HDDs 400GB SSD 1.2TB NVME drive |
|
Fabric Controller | Virtual Node (vND) – app OVA | 16vCPUs | 64GB | 550GB SSD |
Physical Node (pND) (PID: SE-NODE-G2) |
2x 10-core 2.2G Intel Xeon Silver CPU |
256 GB of RAM |
4x 2.4TB HDDs 400GB SSD 1.2TB NVME drive |
|
SAN Controller |
Virtual Node (vND) – app OVA (without SAN Insights) |
16vCPUs | 64GB | 550GB SSD |
Data Node (vND) – Data OVA (with SAN Insights) |
32vCPUs |
128GB |
3TB SSD | |
Physical Node (pND) (PID: SE-NODE-G2) |
2x 10-core 2.2G Intel Xeon Silver CPU |
256 GB of RAM |
4x 2.4TB HDDs 400GB SSD 1.2TB NVME drive |
Scale Limits for Fabric Controller
Profile |
Deployment Type |
Verified Limit |
---|---|---|
Fabric Controller (Non-Production) |
1-Node vND |
<= 25 switches (Non-Production) |
Fabric Controller |
3-Node vND (app OVA) |
80 Switches |
Fabric Controller |
3-Node pND (SE) |
80 Switches |
Scale Limits for Fabric Discovery
Profile |
Deployment Type |
Verified Limit |
---|---|---|
FabricDiscovery |
1-Node vND (app OVA) |
<= 25 switches (Non-Production) |
Fabric Discovery |
3-Node vND (app OVA) |
80 Switches |
Fabric Discovery |
3-Node pND (SE) |
80 Switches |
Description | Verified Limit | ||
---|---|---|---|
Fabric Underlay Overlay | |||
Switches |
80 | ||
Physical Interfaces | 5000 | ||
Layer-3 scenario: Networks | 1000 | ||
Layer 2 scenario: Networks | 1500 | ||
Layer-3 scenario: VRFs | 500
|
||
VRF instances for external connectivity | 300 | ||
Endpoint Locator | |||
Endpoints | 50000 | ||
IPAM Integrator application | 150 networks with a total of 4K IP allocations on the Infoblox server | ||
Multi-Site Domain |
|||
Sites |
8 |
Refer to the following table if you are transitioning a Cisco Nexus 9000 Series switches based VXLAN EVPN fabric management to NDFC. Before the migration, your fabric was an NFM managed or CLI configured fabric.
Description | Verified Limit |
---|---|
Fabric Underlay and Overlay | |
Switches per fabric | 80 |
Physical Interfaces | 5000 |
VRF instances | 100 |
Overlay networks | 500 |
VRF instances for external connectivity | 100 |
Endpoint Locator | |
Endpoints | 50000 |
IPAM Integrator application | 150 networks with a total of 4K IP allocations on the Infoblox server |
Scale Limits for IPFM Fabrics
Description |
Verified Limit |
||
---|---|---|---|
Number of nodes |
35 (2 spines and 33 leafs) |
||
Number of routes |
32000 |
||
Host Policy |
|||
Sender |
8000 |
||
Receiver |
8000 |
||
PIM |
512 |
||
Flow Policy |
2000 |
||
ASM group-range |
20 |
||
NBM Static Flows |
|||
Per switch maximum (receiver leaf where the static OIF will be programmed) mroutes |
1500 |
||
Per fabric maximum mroutes |
8000 |
||
VRFs |
16 |
||
RTP Flow Monitoring with ACL |
|||
ACL |
128 IPv4 ACL entries or 64 IPv6 entries (total 128 TCAM spaces)
|
Scale Limits for SAN Controller
Profile |
Deployment Type |
Verified Limit |
---|---|---|
SAN Controller |
1-Node vND (app OVA) |
80 Switches, 20K Ports |
SAN Controller |
3-Node vND (app OVA) |
80 Switches, 20KPorts |
Profile |
Deployment Type |
Verified Limit |
---|---|---|
SAN Controller |
1-Node vND (data OVA) |
80K ITLs/ITNs |
SAN Controller |
1-Node pND (SE) |
120K ITLs/ITNs |
SAN Controller |
3-Node vND (data OVA) |
150K ITLs/ITNs |
SAN Controller |
3-Node pND (SE) |
250K ITLs/ITNs |