The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This document describes how to troubleshoot commands/registers for issues specifically related to stacking port/cable problems and silent reloads.
Collect and analyze useful registers (for each ASIC and Core). There are three main ones:
show platform hardware fed switch active fwd-asic register read register-name <name>
The first bit tells us if asic is available or not. It is set as 0x1. If it is set as 0x0, then there are forward issues. Error counters or box are not able to recover packets properly.
Switch#sh platform hardware fed switch active fwd-asic register read register-name SifInfo For asic 0 core 0 Module 0 - SifInfo[0][0] available : 0x1 <---- should be 0x1 indicating balloting is completed headerVersion : 0x0 nodeAllLinksAvailable : 0x1 nodeId : 0x4 <---- asic ID (unique across all asics in the stack) numNodes : 0x8 <---- how many asics are there in whole stack serdesSpeed : 0x2 sifAllLinksAvailable : 0x1 sifSupStall : 0x0 wrappedAtRac0 : 0x0 <---- If a single stack port is down, 3 of 6 should wrap w/ value wrappedAtRac1 : 0x0 of 0x1. Will appears in groups for 0, 2 and 4 or 1, 3 and 5. wrappedAtRac2 : 0x0 wrappedAtRac3 : 0x0 wrappedAtRac4 : 0x0 wrappedAtRac5 : 0x0
Note: Each stack cable has six rac rings (ring access control), three outgoing/three incoming at 40Gig each. WrappedAtRac zero to five corresponds whether any stack link is down or not. If things are good, then it is showed as 0x0 (six links per asic, three outgoing, three incoming. For example, odd numbers are outgoing and even numbers are incoming or vice versa).
To check in detail each of the Racs, Critical aspects to verify are displayed; active/linkOk/syncOk bits which tell us if specific Rac has linked up or not (if OK then it is showed as 0x1).
Switch#sh plat hardware fed sw active fwd-asic register read register-name SifRacStatus For asic 0 core 0 Module 0 - SifRacStatus[0][0] active : 0x1 <---- available : 0x1 copyOk : 0x1 disabled : 0x0 insertOk : 0x1 linkOk : 0x1 <---- messageOk : 0x1 noDataOnRing : 0x0 pcsAlignmentOk : 0x1 pcsCodewordSync : 0xf reOrderOk : 0x1 slapId : 0x0 stripOk : 0x1 syncOk : 0x1 <---- toPbcOk : 0x1 transmitOk : 0x1
See if Rac is powered down or not. Check for the greenPowerDisable parameter. This shows 0x0 for all Racs (at least for Nyquist platform). There are some exceptions where it is expected to see Racs power down or greenPowerDisable parameter showed as 0x1 due to HW limitation on the stack cable itself, such as 3650 switch which is the lower end box. Then the stack cable just supports two Racs per asic. The remaining two Racs are powered down.
Switch#sh plat hardware fed sw active fwd-asic register read register-name SifRacControl For asic 0 core 0 Module 0 - SifRacControl[0][0] copyEn : 0x1 deployToken : 0x0 disablePmaChecks : 0x0 forceSync : 0x0 greenPowerDisable : 0x0 <---- init : 0x0 initRacInfoLinkedList : 0x0 insertEn : 0x1 messageEn : 0x1 reOrderEn : 0x1 stripEn : 0x1 toPbcEn : 0x1 transmitEn : 0x1
This is triggered because there is a link change in the system (Up/Down situation). The interrupt is handled at the software level. It is processed to see if there is any link related changes, and then it is published (log generated).
Switch#sh plat hardware fed sw active fwd-asic register read register-name SifExceptionInterruptA4 For asic 0 core 0 Module 0 - SifExceptionInterruptA4[0][0] sifRac0LinkOkChange : 0x0 sifRac0LinkedListSpill : 0x0 sifRac0SyncOkChange : 0x1 sifRac0TransitFifoSpill : 0x0 sifRac1LinkOkChange : 0x0 sifRac1LinkedListSpill : 0x0 sifRac1SyncOkChange : 0x1 sifRac1TransitFifoSpill : 0x0 sifRac2LinkOkChange : 0x0 sifRac2LinkedListSpill : 0x0 sifRac2SyncOkChange : 0x1 sifRac2TransitFifoSpill : 0x0 sifRac3LinkOkChange : 0x0 sifRac3LinkedListSpill : 0x0 sifRac3SyncOkChange : 0x1 sifRac3TransitFifoSpill : 0x0 sifRac4LinkOkChange : 0x0 sifRac4LinkedListSpill : 0x0 sifRac4SyncOkChange : 0x1 sifRac4TransitFifoSpill : 0x0 sifRac5LinkOkChange : 0x0 sifRac5LinkedListSpill : 0x0 sifRac5SyncOkChange : 0x1 sifRac5TransitFifoSpill : 0x0
This is the hardware interrupt which give us details when balloting is done (balloting = asic initialization process). After A8 is completed, the system checks if asic available bit is properly set. If not, then balloting is run again.
Note: When the maximum number is reached, the switch is reloaded with some error saying HW available bit was not set or Balloting did not complete.
Switch#sh plat hardware fed sw active fwd-asic register read register-name SifExceptionInterruptA8 For asic 0 core 0 Module 0 - SifExceptionInterruptA8[0][0] sifBallotDone : 0x0 sifBallotOverallTimerExpires : 0x0 sifBallotPerStateTimerExpires : 0x0 sifBallotSpeedChangeNeeded : 0x0 sifBallotStart : 0x1 sifDebugSent : 0x0 sifEastNeighborChange : 0x1 sifMessageReceiveBufferCreditsEmpty : 0x0 sifMessageReceived : 0x1 sifMessageSent : 0x1 sifNodeIdChanged : 0x1 sifOob3in2DropCntOverflow : 0x0 sifOobFlushDropCntOverflow : 0x0 sifOobStackSifCreditDropCntOverflow : 0x0 sifOobStackSifMtuDropCntOverflow : 0x0 sifOobSupSifMtuDropCntOverflow : 0x0 sifRacInfoLinkedListInitDone0 : 0x1 sifRacInfoLinkedListInitDone1 : 0x1 sifRacInfoLinkedListInitDone2 : 0x1 sifRacInfoLinkedListInitDone3 : 0x1 sifRacInfoLinkedListInitDone4 : 0x1 sifRacInfoLinkedListInitDone5 : 0x1 sifSegmentBuffer0LinkedListSpill : 0x0 sifSegmentBuffer1LinkedListSpill : 0x0 sifSegmentBufferLinkedListInitDone0 : 0x1 sifSegmentBufferLinkedListInitDone1 : 0x1 sifStackTopologyChange : 0x1 sifUnmappedDestIndex : 0x0 sifWestNeighborChange : 0x1
The next command displays SIF Counters that involve SDP messages and SIF management messages. Focus on the failed messages, if any.
Switch#show platform software sif switch active r0 counters Stack Interface (SIF) Counters ------------------------------ Stack Discovery Protocol (SDP) Messages --------------------------------------- Message Tx Success Tx Fail Rx Success Rx Fail ------------------------------------------------------------------------------ Discovery 0 0 0 0 Neighbor 0 0 0 0 Forward 455966 0 1355818 107 --------------------------------------- SIF Management Messages ----------------------- Message Success Fail -------------------------------------------------- Link Status 16 0 Link Management 0 0 Chassis Num 1 0 Topo Change 3 0 Active Declare 1 0 Template set 2 0
There is an additional command that could be run and displays information only when an interrupt goes beyond the threshold. The command is show platform software sif switch active R0 exceptions
. Here is the output when no issues are present on the Interrupts:
Switch#
Switch#show platform software sif switch active R0 exceptions
Switch#
When interrupts are present, the output is similar to the next script. Keep in mind interrupts are expected in some scenarios (bootup, plug/unplug, and so on), so if there is a real issue and continous interrupts, execute the command repeatedly for a period of seconds/minutes.
Switch#show platform software sif switch active r0 exceptions ******************************* Asicnum: 0 SIF INT : SIFEXCEPTIONINTERRUPTA1_SIFRAC5PMARECEIVEFIFOSPILL3_FIELD_IDX Occurred count: 1 First Time: Fri May 18 08:03:23 2018 Last Time: Fri May 18 08:03:23 2018 --------------------------------- SIF INT : SIFEXCEPTIONINTERRUPTA1_SIFRAC5PMARECEIVEFIFOSPILL2_FIELD_IDX Occurred count: 1 First Time: Fri May 18 08:03:23 2018 Last Time: Fri May 18 08:03:23 2018 --------------------------------- SIF INT : SIFEXCEPTIONINTERRUPTA1_SIFRAC5PMARECEIVEFIFOSPILL1_FIELD_IDX Occurred count: 1 First Time: Fri May 18 08:03:23 2018 Last Time: Fri May 18 08:03:23 2018 --------------------------------- SIF INT : SIFEXCEPTIONINTERRUPTA1_SIFRAC5PMARECEIVEFIFOSPILL0_FIELD_IDX Occurred count: 1 First Time: Fri May 18 08:03:23 2018 Last Time: Fri May 18 08:03:23 2018
This table details the most common SIF exceptions from show platform software sif switch active R0 exceptions
:
Exception# | FieldName | Severity | Usage | Description |
0 | sifRac{0:5}PmaTransmitFifoSpill{0:3} | major | Statistic | This fires if the push-pull FIFO between the system clock and serdes clock spills. This cannot occur. If it does, it is likely an indicator that the Serdes clock has been disabled (either by programming or a faulty Serdes.) If this is not due to a programming issue, it is a major issue. But the SIF self-heals. And the net result of a small issue is a lost segment or in extreme cases a re-init. If this was not a small issue, and it is still occuring, then after processing this CHIEF, it re-fires, telling you the condition is still occurring at this point. This transmit link is toast. |
1 | sifRac{0:5}PmaReceiveFifoSpill{0:3} | major | Statistic | This fires if the push-pull FIFO between the system clock and serdes clock spills. This cannot occur. If it does, it is likely an indicator that the Serdes clock has been disabled (either by programming or a faulty Serdes.) If this is not due to a programming issue, it is a major issue. But the SIF self-heals. And the net result of a small issue is a lost segment or in extreme cases a re-init. If this was not a small issue, and it is still occuring, then after processing this CHIEF, it re-fires, telling you the condition is still occurring at this point. This transmit link is toast. |
2 | sifRac{0:5}SerdesLossOfLock{0:3} | major | Statistic | To be used in correlation with sifRac{0:5}PmaReceiveFifoSpill{0:3} to inform about the condition of the received Serdes clocks w.r.t. normal operation condition. If they are out-of-spec, then the IdleDensity Timer cannot compensate for the difference. In general, this is an problem checker to ensure the assumption that the receiever Serdes are working properly is actually true. |
3 | sifRac{0:5}ClockLossOfLock{0:3} | major | Statistic | To be used in correlation with sifRac{0:5}PmaReceiveFifoSpill{0:3} to inform about the condition of the received Serdes clocks w.r.t. normal operation condition. If they are out-of-spec, then the IdleDensity Timer cannot compensate for the difference. In general, this is an problem checker to ensure the assumption that the receiever Serdes are working properly is actually true. |
4 | sifRac{0:5}syncOkChange | minor | Monitor | Indication of link-flap |
sifRac{0:5}linkOkChange | minor | Monitor | Indication of link-flap | |
sifRac{0:5}linkedListSpill | major | Monitor | Rac linked lists that are part of the reorder algorithm have exceeded the maximum entries possible. This is real bad and means that the reorder is now tail-dropping data segments and OOB messages on this RAC. This cannot occur unless the stack is mis-configured or the linked list has experienced a soft error. See Exception 9 and10. | |
sifRac{0:5}transitFifoSpill | major | Statistic | The transitFifo reponsible for moving data through the SIF to other nodes has spilled this is likely due to a mis-configuration of the IdleDensityTimer w.r.t. to the actual Serdes clock ppm (parts per million) offset for this switch vs. its neighbor. | |
5 | sifRac{0:5}missingToken | major | Statistic | The Stack conch shell has been lost, corrupted, re-depolyed, and so. This is likely an indication that a bit-hit on the stack hit a SifTokenDesc. This is a very unlikely thing to happen. The SIF can be configured to deal with this in different ways. Either re-ballot and start over, re-deploy a token, or allow the SIF to re-deploy. |
sifRac{0:5}duplicateToken | major | Statistic | ||
sifRac{0:5}tokenDeployed | info | Statistic | ||
6 | sifRac{0:5}RwCrcErrorCntOverflow | minor | Statistic | Likely all indicators of the stack cable or neighbor box being comproimsed. Broken out to this detail largely for debugging. In the course of normal operation syncOkChange and linkOkChange are all you need to know. In collecting LONG-TERM-BER, you have to monitor and count these when the counters roll-over for proper counting of bit-errors. It is possible that when an invalidRw or pcsCodeWordError is present, the CRC is not checked. That way you can sum all these registers for BER. |
sifRac{0:5}DataCrcErrorCntOverflow | minor | Statistic | ||
sifRac{0:5}InvalidRwErrorCntOverflow | minor | Statistic | ||
sifRac{0:5}PcsCodeWordErrorCntOverflow | minor | Statistic | ||
7 | sifRac{0:5}RdispErrorCntOverflow | minor | Statistic | |
sifRac{0:5}PrbsUnLockErrorCntOverflow | info | Statistic | Bring up stats for use in helping find the best configuration of the IBM HSS macros to find the optimal programmings. | |
sifRac{0:5}PrbsBitErrorCntOverflow | info | Statistic | ||
sifRac{0:5}ErrorCaptureCntOverflow | info | Lab | Bring up stats for capturing the form of errored ringWords for inspection to see what is happening on the Stack. | |
8 | sifRacInfoLinkedListInitDone{0:5} | info | Monitor | HW initialization of the RAC linked list is complete. |
sifDroppedSegmentCntOverflow | info | Statistic | ||
sifPbcInconsistentSopEopCntOverflow | info | Statistic | Worst case scenario. Check for data arrival as per protocol form from PBC. | |
sifPbcErrorCntOverflow | info | Statistic | ||
sifSupInconsistentSopEopCntOverflow | info | Statistic | Worst case scenario. Check for data arrival as per protocol form from SUP (OOBM). | |
sifSupErrorCntOverflow | info | Statistic | ||
sifReorderInconsistentSopEopCntOverflow | info | Statistic | Indication that the missing segment indicator has rolled over. | |
sifDebugSent | info | Lab | Bring up indication for insertion of debug Segments onto the stack. | |
sifMessageSent | info | Lab | Due to the automated nature of the OOBM, these are really only useful in lab situations. | |
sifMessageReceived | info | Lab | ||
sifMessageDropped | info | Lab | ||
sifMessageReceiveBufferCreditsEmpty | minor | Monitor | Please refresh Credits if this fires. The credit level is actively monitored so that this does not trip. | |
sifUnmappedDestIndex | minor | Statistic | During the Copy/Strip, it couldn not map the destIndex and a portCopy was set to '0' and portStrip set to '1'. This indicates a configuration issue. | |
sifSegmentBuffer{0:1}linkedListSpill | major | Monitor | Segment linked lists that are part of reorder have exceeded the maximum entries possible. This is an indication that the reorder is now tail-dropping data segments and OOB messages. This cannot occur unless the stack is mis-configured or the linked list has experienced a soft-error. See Exception 9 and 10. | |
sifSegmentBufferLinkedListInitDone{0:1] | info | Monitor | HW initialization of the segment linked list is complete. | |
sifBallotDone | info | Monitor | Indication Balloting has completed. | |
sifBallotSpeedChangeNeeded | info | Monitor | Since the last successful ballot, a new speed is required on the stack link. This means that a Node has entered the stack has changed the dynamic of the stack speed. Either by being slower than the current speed, the stack has to adjust down. Or by being faster than it was previously. It can be the result of a new shorter cable. | |
sifEastNeighborChange | info | Monitor | Monitor for stack bring-up, merge, and wrap scenarios. | |
sifWestNeighborChange | info | Monitor | ||
sifNodeIdChanged | info | Monitor | Indication that as a result of the last ballot, the SifInfo.nodeId has been changed. | |
sifStackTopologyChange | info | Monitor | Monitor for stack bring-up, merge, and wrap scenarios. | |
9 | sifRacInfoBuffer{0:5}EccCorrected | major | Monitor | sifRacInfoBuffer{0:5} was hit with a soft-error. This is bad, but the worst-case result is some out-of-order packets or later packet drops in the egress datapath. Resetting Doppler is not required here. |
sifRacInfoBuffer{0:5}EccDetected | major | Monitor | ||
sifRacInfoLinkedListBuffer{0:5}EccCorrected | major | Monitor | sifRacInfoLinkedListBuffer{0:5} was hit with a soft-error. Depending on the over-arching HA guideline for this SW load, you want to Reset Doppler. This can cause performance issues to SifReorder. | |
sifRacInfoLinkedListBuffer{0:5}EccDetected | major | Monitor | ||
sifSegmentLinkedListBuffer{0:1}EccCorrected | major | Monitor | sifRacInfoLinkedListBuffer{0:5} was hit with a soft-error. Depending on the over-arching HA guideline for this SW load, you want to Reset Doppler. This can cause performance issues to SifReorder. | |
sifSegmentLinkedListBuffer{0:1}EccDetected | major | Monitor | ||
10 | DestinationIndexTabeParityError | major | Monitor | Memory was hit with a parity error. Reload contents and recognize that some packets can have mis-copied/stripped as a result. Reset Doppler is probably not required. |
GlobalToLocalPortTable | major | Monitor | ||
CpuIndexTable | major | Monitor | ||
HashTableA | major | Monitor | ||
HashTableB | major | Monitor | ||
MessageQueueFifo | major | Monitor | Message control memories were hit with a soft-error. This is a transient issue that can lead to a mis-forwarded or out-of-order OOB. This can self heal and does not require a Doppler reset as new users of the entries here can overwrite the old ones. | |
MessageQueueLinkBuffer | major | Monitor |
This is found in EDCS-757121:NG3K SIF Driver Software Functional Specification.
to understand details for each register.
Cli to monitor health of stack ports:
show platform hardware fed switch <> fwd-asic register read register-name SifSerdesHssMacroStatus
show platform hardware fed switch <> fwd-asic register read register-name SifInfo
show platform hardware fed switch <> fwd-asic register read register-name SifRacStatus
show platform hardware fed switch <> fwd-asic register read register-name SifRacControl
show platform hardware fed switch <> fwd-asic register read register-name SifExceptionInterruptA8
show platform hardware fed switch <> fwd-asic register read register-name SifExceptionInterruptA4
show platform hardware fed switch <> fwd-asic register read register-name SifStatistics
show platform hardware fed switch <> fwd-asic register read register-name SifRacInsertedCnt
show platform hardware fed switch <> fwd-asic register read register-name SifRacCopiedCnt
show platform hardware fed switch <> fwd-asic register read register-name SifRacPmaControl
show platform hardware fed switch <> fwd-asic register read register-name SifBallotWatchDogTimer
show platform hardware fed switch <> fwd-asic register read register-name SifPbcSifErrorCnt
show platform hardware fed switch <> fwd-asic register read register-name SifMessageStatus
show platform hardware fed switch <> fwd-asic register read register-name SifControl
show platform hardware fed switch <> fwd-asic register read register-name SupStackInterfaceControl
show platform hardware fed switch <> fwd-asic register read register-name SifSifPbcCnt0
show platform hardware fed switch <> fwd-asic register read register-name SifSifPbcCnt<>
show platform hardware fed switch <> fwd-asic register read register-name SifSifPbcDroppedCnt
show platform hardware fed switch <> fwd-asic register read register-name SifSerdesHssChannelStatusRx
show platform hardware fed switch <> fwd-asic register read register-name SifSerdesHssChannelStatusTx
show platform hardware fed switch <> fwd-asic register read register-name SifRacDataCrcErrorCnt
show platform hardware fed switch <> fwd-asic register read register-name SifgRacRwCrcErrorCnt
show platform software sif switch <> R0 counters
show platform software sif switch <> R0 exceptions
.
After you are in the Linux Shell, proceed with the next script:
[Switch_2_RP_0:~]$ dope.sh Num Asics: 0 Cat9300 platform dope vft **************************************************** DOPpler Examiner http://wwwin-dopplersdk.cisco.com **************************************************** Detecting number of asics...found 1 asics asic-0: phy_addr=0x87f80000000 virt_addr=0x7f84d746f000 Loading Library : libasd2_DL.so ... Success. (null) ASIC Layer libraries successfully loaded!!! ASIC version: 0x448 Starting ASIC Driver create Driver and Device Init Completed. dope[0,0]> rdsp SifControl <------- rdsp <register name>
The previous script is reading switch one, asic zero. Change this performing this script:
dope[0,0]> asic 1 <--- changes to asic 1
dope[1,0]>
Note: Dope.sh (Doppler shell) is the lowest level in the hardware programming. This is how you read the ring values directly from the hardware. Use the Other Stacking Registers in the prior script after the rdsp
command to get the most granular data (if needed).
Whenever there is a silent reload (no crashdump/system_report generated), there are crash tracelogs displaying some specific files to get more information related to what could cause the event.
We can start looking at stack_mgr_R0 first and see from its perspective the reason for the reload. Such as:
We can now move to pvp logs. Use the timestamps extracted from stack_mgr_R0 (specifically when reload occurred) and look through pvp_F0 and pvp_R0 to identify when the processes termination sequence started before it executes all the reload orchestration sequence. Such as:
Note: It can show pvp_F0 and pvp_R0.
Note: Make sure to check both because you could see linux_iosd_image process terminating in pvp_R0, but a different process within pvp_F0 was terminated before. This is a key factor because the very first process that is killed. Then it can point to the trigger of the problem.
Within pvp_F0 and pvp_R0, there is also an exit code provided after the process dead/held-down. For real process crashes, exit codes 129 and so are used. This is how pvp is aware that crashdump/system_report needs to be created. With no crashdump/system_report, the exit code normally is zero. Such as:
After identifying the culprit process, go to the process related btrace logs and check for more details.
It is possible for a single bad cable between two switches to cause any switch in the stack to reload due to lost keepalives.
Stack traces, or switches, actively experiencing the issue produces these errors:
The bookkeep checks every one second for the last time it heard from each switch in the stack (from the perspective of the switch running the bookkeep). After 8000 msec of no keepalives, we start printing traces that peers have not been heard. At 16000 msec, the switches in question reload for lost keepalives.
9300-1#sh switch stack-ports sum Load for five secs: 8%/4%; one minute: 9%; five minutes: 9% Time source is NTP, 11:53:11.196 EDT Thu May 17 2018 Sw#/Port# Port Status Neighbor Cable Length Link OK Link Active Sync OK #Changes to LinkOK In Loopback ------------------------------------------------------------------------------------------------------------------- 1/1 OK 2 100cm Yes Yes Yes 2 No 1/2 OK 8 300cm Yes Yes Yes 143 No <----------- 2/1 OK 3 50cm Yes Yes Yes 1 No 2/2 OK 1 100cm Yes Yes Yes 1 No 3/1 OK 4 50cm Yes Yes Yes 1 No 3/2 OK 2 50cm Yes Yes Yes 1 No 4/1 OK 5 50cm Yes Yes Yes 1 No 4/2 OK 3 50cm Yes Yes Yes 1 No 5/1 OK 6 50cm Yes Yes Yes 1 No 5/2 OK 4 50cm Yes Yes Yes 1 No 6/1 OK 7 50cm Yes Yes Yes 1 No 6/2 OK 5 50cm Yes Yes Yes 1 No 7/1 OK 8 50cm Yes Yes Yes 1 No 7/2 OK 6 50cm Yes Yes Yes 1 No 8/1 DOWN NONE 300cm No No Yes 116 No <---------------- 8/2 OK 7 50cm Yes Yes Yes 1 No
This timeout was also seen where there was a large amount of instability in the stack link between to switches, eventally causing one switch to believe the stack port was up and able to pass traffic, but the other thinking it was down.
The stack-ring operates in both a clockwise and counter-clockwise direction. Traffic on the ring can take either path regardless of its destination. This means that if switch 2 wants to send a keepalive to switch 1, it can go through switches 3, 4, 5, 6, 7, 8 and then 1, or just from from 2 directly to 1. Return traffic from switch 1 to switch 2 that happens to hash toward switch 8 would have been dropped, leading to the timeouts seen in the previous script.