This document will cover several areas to analyze when troubleshooting Cisco Business Wireless (CBW) mesh networks.
If you have a traditional wireless network, you should check out Troubleshooting a Traditional Cisco Business Wireless Network.
Mesh wireless networks are awesome, but let’s face it, things happen! Just like any wireless network, a number of things can cause problems. Sometimes there is a simple fix, while others might be more complicated.
If you are unfamiliar with terms in this document, check out Cisco Business: Glossary of New Terms.
Ready for some troubleshooting? Let’s dig in!
This toggled section highlights tips for beginners.
Log into the Web User Interface (UI) of the Primary AP. To do this, open a web browser and enter https://ciscobusiness.cisco.com You may receive a warning before proceeding. Enter your credentials.You can also access the Primary AP by entering https://[ipaddress] (of the Primary AP) into a web browser.
If you have questions about a field in the user interface, check for a tool tip that looks like the following:
Navigate to the menu on the left-hand side of the screen, if you don’t see the menu button, click this icon to open the side-bar menu.
These devices have companion apps that share some management features with the web user interface. Not all features in the Web user interface will be available in the App.
If you still have unanswered questions, you can check our frequently asked questions document. FAQ
This is the easiest way to troubleshoot but is often overlooked. Even though these may appear to be obvious, it is good to start with the basics.
Every SSID requires sending a beacon frame every 100 milliseconds (ms), which can eat up a lot of channel utilization.
It is best to limit the total number of SSIDs on the AP to 1-2 SSIDs per radio or per AP, even though the mesh network can support up to a physical limit of 16 SSIDs per radio.
Perhaps you have tried to log into ciscobusiness.cisco, and are encountering problems. Check out these simple suggestions:
Firmware, also referred to as software, comes embedded on your access point. Upgrading firmware improves the performance and stability of your AP. Upgrades may include new features or fix a vulnerability that was experienced in the previous version of the software. Is it really that important? Absolutely! It is so vital that all the links for upgrades were added in the Firmware Version section of this article. This could be a simple solution to try if you are having network problems. You may have issues when adding the first Mesh Extender to a network if there is a firmware version mismatch, so why not update them all right away!
It is extremely important to update all Mesh Extenders before updating the Primary Capable APs.
You can upgrade the firmware in a number of ways, but it is recommended that you use Cisco.com for the upgrade. If you would like assistance in upgrading firmware, check out Update Software of a Cisco Business Wireless Access Point.
Sometimes an upgrade doesn’t go smoothly. There are some simple things you can try:
The AP must be able to communicate with other devices to be effective. A simple way to check this is to perform a ping.
Ping the AP from at least two clients that are connected (associated) to that particular access point.
Ping from the router to the access point IP address to see if end-to-end connectivity is available. Ping from the router to the wireless clients associated with the AP to check if they can be reached from the main network.
Even though you probably assigned a static IP address to your Primary AP, this AP still needs to have access to a DHCP server. This DHCP server must be operational and reachable from the LAN Ethernet port of the AP. This is necessary so the Primary AP can provide IP addresses for all APs and clients that join the network. If you see a blinking red light on the Primary after a reboot, this could be your problem.
Even though a static IP address can be chosen for CBW management, it only applies to the managemetnt IP address. Every access point, including mesh extenders need a separate IP address for its access point functionality. The management MAC address is 00:00:5e:00:01:01.
Even if all CBW addresses are configured as static, adding a new AP or mesh extender still requires a DHCP server for the initial installation of the new device, even if you plan to change it to a static IP address later.
It’s possible that there are more clients needing an IP address than are available in the DHCP pool. See the section How to View or Change the Pool of IP Addresses for DHCP section the article Best Practices for Setting Static IP Addresses on Cisco Business Hardware for more information.
There may be times where too many DHCP addresses are cached, which can also prevent clients from getting an IP address. To learn more about this, check out Tips to Keep the ARP Table Available for DHCP IP Addressing. You may also reboot the router if this is more convenient.
If you use Windows, select your wireless connection from the Network Connections panel and verify that its status is Enabled.
Detailed guidance can be found at the Microsoft Support Forum for troubleshooting wireless network connectivity at the clicking on the following link: Fix Wi-Fi connection issues in Windows.
There are some default settings that might cause connection issues in some older devices. You can try changing the following settings.
Make sure you are in Expert View for these settings.
Navigate to Advanced > RF Optimization. Toggle on RF Optimization.
Scroll down to the bottom of this screen. Within each radio Data Rates, remove support for lower control rates to remove older legacy wireless mode clients, such as 802.11b clients.
A notification will come up that older devices are not supported. The further to the right you slide, the less that can connect.
When you conducted the Day Zero configurations for your mesh network, a BGN was automatically created. It is the same as the first Service Set Identifier (SSID) you entered, up to the first 10 characters. This BGN is used within APs to associate and make sure the APs are staying connected properly. If you set up your Primary AP and then join subordinate APs, the BGN should automatically match with no further configurations needed.
If you perform a reset to factory default on the Primary AP, or move APs from one configured network to another, this can cause a mismatch of BGNs.
When an AP tries to join a network in a scenario where the BGN doesn’t match any networks available, the subordinate AP will still attempt to temporarily join the network with the strongest signal. The AP will be able to join the network if it is Allow Listed and approved.
Once the AP has joined the network, since the BGN doesn’t match, the subordinate AP will continue to look for a matching BGN every 10 to 15 minutes. This will cause the connection to drop and then join again if a matching BGN isn’t found. This can cause a lot of problems with connectivity in the wireless network, especially when there might be a stronger wireless signal coming from another wireless network.
As a simple solution, for all APs to work together, you should make sure the BGN on all APs match exactly. To clear out the BGN on the other APs, you can do a factory reset on them, or you can manually change each one to match.
It is recommended that BGNs get assigned to the mesh extenders with the most hops be configured first, working up to the least number of hops. After that, the Primary Capable APs BGNs should be assigned. The Primary AP BGN should be configured last. You can view and change them one at a time by performing the following steps.
Log into the AP and enter your credentials.
Switch to Expert View by clicking on the arrow icon.
Navigate to Wireless Settings > Access Points. Click on the edit icon of the AP you want to edit or view.
A pop-up will ask for confirmation that you want to edit the AP configuration. Select Yes.
Click the Mesh tab. Here you can view and change the Bridge Group Name. If you make changes, be sure you click Apply.
Repeat the steps for each AP in the network you want to check. Click the save icon to permanently save any changes. Keep in mind that when a bridge group name is assigned, the device performs a reboot. Since a reboot interrupts Wi-Fi, it is not recommended during business hours.
In order to connect other Primary-capable APs and mesh extenders, you need to create an Allow List on a Primary AP that includes the Media Access Control (MAC) address of all the APs.
In addition, subordinate APs need to be Allow Listed so that the Primary AP can access and upgrade the other APs, which is essential to keep the network up and running.
This Allow List, along with all APs having the same Bridge Group Name (BGN), helps the APs connect efficiently and consistently. To add a Media Access Control (MAC) address and label it as Allow List, complete the following steps.
You need to know the MAC address of the AP. If you know the MAC address of your AP, you can skip to Step 4.
A MAC address includes numbers and letters in pairs, separated by colons.
On most APs, the MAC address can be found on the outside of the actual AP. On the 142ACM and 143ACM you need to slide out the power apparatus to view the MAC address. To do this, apply light pressure on the AP where the arrows indicate. Slide and lift the power component out.
On the 142ACM and 143ACM, you will see the MAC address in the locations pointed out below.
Enter the following information:
Interference can cause issues on wireless networks and can come from more sources than ever before. Microwaves, security cameras, smartwatches, motion detectors, or even fluorescent bulbs can cause interference.
How much they affect the network can depend on many factors including the amount of power emitted if the object is constantly on, or if it is intermittent. The stronger the signal or the more frequently it is on the more problems that can arise.
Rogue APs and rogue clients can cause problems if there are too many on the same channel as well.
Interference can be a major inhibitor to wireless performance, creating security vulnerabilities and wireless network instability.
There are tools available to monitor the channel(s) you are currently utilizing. You have the ability to change channels as well. Check out the following articles for more information.
The following chart lists the expected coverage areas in an open space. If you deploy your network in an area that is not open, reduce these values by 20-30%.
In all networks, you need to work on a strong signal between clients and the APs. In a mesh network, you also need to make sure there is a strong signal between the various APs between each other. If one of the “hops” doesn’t have a great signal, a higher signal to noise ratio, you will need to troubleshoot that. You may need to adjust the location or check to see what is causing interference.
Navigate to Monitoring > Network Summary > Access Points and click on any access point in the table to check the associated client signal strength.
Once the Access Point View opens, look over the information under Performance Summary.
You can also gather information on all mesh extender Hop counts and Signal to Noise Ratio. Navigate to Monitoring > Network Summary > Mesh Extender.
Being aware of events can help ensure the network runs smoothly and prevent failures. Syslogs are useful for network troubleshooting, debugging packet flow, and to monitor events.
These logs can be viewed on the Web User Interface (UI) of the Primary AP and if configured, on remote log servers. Events are typically erased from the system when rebooted if they are not saved on a remote server.
If you would like more information, check out Setting Up System Message Logs (Syslogs) on a CBW Network.
A feature that is available on this CBW equipment is to download a support bundle. A support bundle is a tool that can be helpful in troubleshooting. It provides the AP boot-up logs and specifies the configurations applied. To get a complete picture, this might need to be done on every AP.
Before downloading the support bundle on the Primary AP, make sure you are running the most current release of firmware. To update firmware, select the correct link under Applicable Devices | Firmware Version. If you would like assistance in upgrading firmware, check out Update Software of a Cisco Business Wireless Access Point.
To download the tech support bundle specific to access point functionality, select Monitoring > Access Points. Select the AP you would like to access.
Under the Tech Support section, select Start.
When the download is complete, you will see the Tech Support Status is Completed. Select the Download button to download the files. At this point, even if the download happens to fail, it is deleted from the memory of the AP. This would happen if you don’t allow pop-ups.
In the Download folder of your computer files, you will see a tech support .tgz file. The files inside this folder need to be extracted.
Right-click and select the unzip application that you would like to use. In this example, 7-Zip was used. Select to extract the files to the location you select. By default, the files are sent to the Downloads folder.
(Alternative View) If you have a core crash, you might see these folders instead.
Once the files have been extracted from the .tgz file, they will be in a .tar file. This file will need to be extracted again.
You will see the tech_support folder. Double-click on the folder to open the files.
Within the support bundle, the cli_file (configuration file), msg/syslogs (event logs), and startlog provide the most relevant information. The files you see may vary. An example is shown here.
Right-click on the file you would like to unzip. In this example, the file will be unzipped into a folder for tech_support.
The tech_support folder will appear. Double-click to open the folder.
Right-click on the file and select a text file reader. In this example, we used Edit with Notepad++.
The Primary AP tech support bundle is the main source of diagnostics. To download the tech support bundle that is built into the Primary AP or the virtual controller bundle, navigate to Advanced > Primary AP Tools. Select the Troubleshooting Files tab. Select Download Support Bundle. For Transfer Mode, select HTTP or FTP. Click Apply settings. Click on the Save icon.
Change the 802.11r settings on the CBW Network
Access the Web User Interface (UI) by entering the IP address of the Primary Access Point into a web browser. Make sure you are not on a Virtual Private Network (VPN) or this will not work. If you encounter security warnings, select the prompts to proceed.
In the upper right-hand of the Web UI, click on the opposing arrows to switch to expert view.
A pop-up window will appear, asking if you want to select expert view. Click OK.
Select WLANs and the edit icon for the WLAN you want to edit.
A pop-up window will appear, asking if you want to continue. Click Yes.
Click on the Advanced tab. Click on the drop-down menu for 802.11r and select Enabled.
Click Apply.
To permanently save these settings, click the save icon on the top right of your screen.
An option of last resort, that should only be done to remedy the most severe issues such as losing the ability to gain access to the management portal, is to perform a hardware reset on the router.
When you reset to factory default settings you lose all configurations. You will need to set up the router again from scratch so make sure you have the connection details.
The process on the new CBW APs is a little different than you may have experienced on other APs. For details on the reset, check out the article Reset a CBW AP back to Factory Default Settings.
It was our intention to give you several different options for troubleshooting your mesh network. Mission accomplished! You should now have connectivity and can move on with your day.