THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
06-May-22 |
Initial Release |
Affected Product ID | Comments |
---|---|
CS-CODEC-PRO+ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-KITPRO-K9 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-K9 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-KITPRO-P60-K9 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-K7 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR-K9 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR+ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR= |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO= |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-K9++ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR++ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO++ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-MM-K9 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-KITPRO-PTZ4K-K9 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR+ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR= |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODEC-PRO-NR++ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODECPRO-NR-K7= |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODECPRO-NR-K7+ |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
CS-CODECPRO-NR-K7 |
Customers are recommended to install software version 10.11.5.2 or later, which increases the power supply fan speed in order to improve the internal ventilation. |
Defect ID | Headline |
---|---|
CSCwb41132 | Codec Pro, improved internal heat control |
Inadequate cooling can cause the power supply in the Codec Pro to overheat and fail, which results in unrecoverable failure of the device.
A number of factors can cause the power supply to overheat, such as installation location, air temperature, and air flow rate.
The device might unexpectedly shut down and become unresponsive.
If the device is operational, install software Version 10.11.5.2 or later, which increases the power supply fan speed in order to improve internal cooling. If the device has already failed, follow the normal Return Material Authorization (RMA) process as per your service agreement or warranty terms, as there is no workaround once the failure has occurred.
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
My Notifications—Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.
Unleash the Power of TAC's Virtual Assistance