THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
20-Mar-19 |
Initial Release |
Affected OS Type | Affected Software Product | Affected Release | Affected Release Number | Comments |
---|---|---|---|---|
NON-IOS |
NX-OS System Software |
7 |
7.0(3)I7(1), 7.0(3)I7(2), 7.0(3)I7(3), 7.0(3)I7(4), 7.0(3)I7(5) |
The fix is to upgrade the EPLD of the system to the EPLD packaged with NX-OS releases 7.0(3)I7(5a), 9.2(2) and later. |
NON-IOS |
NX-OS System Software |
9 |
9.2(1) |
The fix is to upgrade the EPLD of the system to the EPLD packaged with NX-OS releases 7.0(3)I7(5a), 9.2(2) and later. |
NON-IOS |
APIC Software |
3.0 |
3.0(1k), 3.0(2h), 3.0(2k), 3.0(2n) |
The fix is to upgrade the EPLD of the system to the EPLD packaged with ACI releases 3.2(5d) or 4.1(1x) |
NON-IOS |
APIC Software |
3.1 |
3.1(1i), 3.1(2m), 3.1(2o), 3.1(2p), 3.1(2q), 3.1(2s), 3.1(2t), 3.1(2u) |
The fix is to upgrade the EPLD of the system to the EPLD packaged with ACI releases 3.2(5d) or 4.1(1x) |
NON-IOS |
APIC Software |
3.2 |
3.2(1l), 3.2(1m), 3.2(2l), 3.2(2o), 3.2(3i), 3.2(3n), 3.2(3o), 3.2(3r), 3.2(3s), 3.2(4d), 3.2(4e) |
The fix is to upgrade the EPLD of the system to the EPLD packaged with ACI releases 3.2(5d) or 4.1(1x) |
Defect ID | Headline |
---|---|
CSCvm94301 | N9K-C9348GC-FXP has no console access after software upgrade or CLI reload |
CSCvn26568 | Update BIOS and EPLD for ACI Leaf |
The N9K-C9348GC-FXP switch might fail to boot after a reload or disruptive software upgrade. The console will be unresponsive and all LEDs will be off, except for the Power LEDs.
This condition can only be triggered during a reload (not a hard power cycle) and does not impact a switch that is up and running. This is triggered by a firmware bug in the power supply unit (PSU) timing sequence and is addressed by an electronic programmable logic device (EPLD) software update.
The console will be unresponsive.
In order to recover the system, complete one of these options:
The fix is to upgrade the EPLD of the system to the EPLD packaged with NX-OS release 7.0(3)I7(5a), 9.2(2), or later.
Application Centric Infrastructure (ACI)
The fix is to upgrade the ACI version to 3.2(5x), 4.1(1x) , or later.
Upgrade the Software
The fix for this issue is available as an EPLD firmware upgrade. An upgrade to the NX-OS alone is not sufficient. Cisco recommends for the customer to upgrade the NX-OS code and then upgrade the EPLD version.
See Recommended Cisco NX-OS Release for Cisco Nexus 9000 Series Switches and EPLD Installation Procedure for more information.
For ACI, EPLD upgrades are automatically completed with the ACI version upgrade.
This affects N9K-C9348GC-FXP with IO FPGA less than 0x08.
In order to find the Product ID, enter the show mod | grep active command. An example is shown here.
switch# show mod | grep active 1 54 48x100/1G + 4x10G/25G + 2x40G/100G Et N9K-C9348GC-FXP active *
In order to view the IO FPGA version, enter the slot 1 show hardware internal version command. An example is shown here.
switch# slot 1 show hardware internal version ------------------------------------------------------------------- Name InstanceNum Version Date ------------------------------------------------------------------- Homewood 0 0x01 POE 0 0x00 IO FPGA 0 0x06 20170615 MI FPGA 0 0x08 20170515 CPLD1 0 0x01 CPLD2 0 0x01