THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
29-Mar-17 |
Initial Release |
10.0 |
11-Oct-17 |
Migration to new field notice system |
Affected OS Type | Affected Release | Affected Release Number | Comments |
---|---|---|---|
NON-IOS |
5.4.0.8 |
||
NON-IOS |
6.0.1 |
Defect ID | Headline |
---|---|
CSCuz99094 | Infinite loop in arj_read_main_header() |
Firepower sensors that run Software Version 6.0.1 or earlier might experience SFDataCorrelator threads that become unresponsive.
Firepower sensors that run Software Version 6.0.1 or earlier might experience SFDataCorrelator threads that become unresponsive. This can cause failures in these Firepower sensor functions: GeoDB updates, URL categories/reputations, user-to-ip mapping updates, and policy deployments.
Policy updates cannot be applied to the Firepower sensor.
Disable "inspect archives" in the advanced settings of the File Policy settings.
Upgrade the Firepower Sensor to Software Version 6.1.0 or later. This software is available from Cisco Software Central for customers with a valid service contract.
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Cisco Notification Service—Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.