THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
13-Jan-16 |
Initial Release |
10.0 |
09-Oct-17 |
Migration to new field notice system |
10.1 |
26-Jul-18 |
Updated the Defect Information Section |
Affected Product ID | Comments |
---|---|
N5K-C5596T-FA |
|
N5K-C5596UP |
|
N5K-C5596UP-FA |
|
UCS-FI-6296UP |
Defect ID | Headline |
---|---|
CSCun00720 | UCS 6296 FI System fails to boot after a power cycle |
CSCun66310 | Nexus 5596: System fails to boot after a power cycle |
Some Nexus 5596 and Unified Computing System Fabric Interconnect (UCS FI) 6296 systems fail to boot after a software upgrade, reload, or power cycle. This problem is rare in occurrence but has been seen in the field.
The failure signature is no console output and the status LED remains solid green.
The issue is only seen on N5K-C5596UP, N5K-C5596T, and UCS-FI-6296UP. This DOES NOT affect the Nexus 50x0, Nexus 5548, Nexus 5600 Series, UCS FI 6100 Series, or UCS FI 6248.
There are two power controller devices in the system and each controller device controls four ASIC devices 0.9V power rails on board. It was found that the firmware on the two controllers have different soft-start compensation parameters.
In order to correct the issue a script needs to be run on the system to update the controller settings. This can be done in the field, but requires assistance from the Technical Assistance Center (TAC).
After a power cycle there is no console output and the status LED remains solid green.
Refer to the "How to Identify Affected Products" section for instructions on how to view the version of an in-service product.
If the hardware shows the Updated Hardware Version or later, no action is required.
If the hardware shows the Impacted Hardware Version or earlier, please call TAC or your account team for further assistance. The controller configuration settings can be corrected in the field with TAC assistance.
Enter this command in nxos mode and see the table in order to determine if the hardware is impacted:
5596(nxos)# show sprom sup | inc H/W H/W Version : 1.0 5596(nxos)#
PID | Impacted Hardware Versions | Updated HW Versions (Not Impacted) |
---|---|---|
UCS-FI-6296UP | 1.0 | 1.1 |
N5K-C5596UP | 1.0 | 1.1 |
N5K-C5596T | 1.1 | 1.2 |
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Cisco Notification Service—Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.
Unleash the Power of TAC's Virtual Assistance