The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.

Available Languages

Download Options

  • PDF
    (572.5 KB)
    View with Adobe Reader on a variety of devices
Updated:May 7, 2020
 

 

Product overview

The Cisco Nexus® 7000 Series Switches are the foundation of the Cisco® Unified Fabric solution. Designed to meet the requirements of mission-critical data centers, these switches deliver exceptional availability, outstanding scalability, and the proven and comprehensive Cisco NX-OS Software data center switching feature set.

The Cisco Nexus 7700 Switches are the latest extension to the Cisco Nexus 7000 Series modular switches. With more than 83 Terabits per second (Tbps) of overall switching capacity, the Cisco Nexus 7700 Switches delivers the highest-capacity 10, 40, and 100 Gigabit Ethernet ports in the industry, with up to 768 native 10-Gbps ports, 384 40-Gbps ports, or 192 100-Gbps ports. This high system capacity is designed to meet the scalability requirements of the largest cloud environments.

The Cisco Nexus 7700 switches (Figure 1) have operational and feature consistency with the existing Cisco Nexus 7000 Series Switches, using common system architecture, the same Application-Specific Integrated Circuit (ASIC) technology, and the same proven Cisco NX-OS Software releases.

Cisco Nexus 7700 Switches

Figure 1.            

Cisco Nexus 7700 Switches

Features and benefits

Powered by Cisco NX-OS, the Cisco Nexus 7700 switches deliver a comprehensive set of features with nonstop operations in four chassis form factors:

      Cisco Nexus 7700 2-Slot Switch: A 2-slot switch with two front-accessible module slots with front-to-back airflow and an integrated cable management system

      Cisco Nexus 7700 6-Slot Switch: A 6-slot switch with six front-accessible module slots with front-to-back airflow and an integrated cable management system

      Cisco Nexus 7700 10-Slot Switch: A 10-slot switch with 10 front-accessible module slots with front-to-back airflow and an integrated cable management system

      Cisco Nexus 7700 18-Slot Switch: An 18-slot switch with 18 front-accessible module slots and front-to-back airflow with integrated cable management system

All Cisco Nexus 7000 Series chassis use a passive mid-plane architecture, providing physical connectors and copper traces for interconnecting the fabric modules and I/O modules for direct data transfer. All inter-module switching is performed via crossbar fabric ASICs on the individual I/O modules and fabric modules.

A scalable, fully distributed fabric architecture uses up to six fabric modules to deliver up to 1.32 Tbps per slot of bandwidth in the Cisco Nexus 7700 6-, 10-, and 18-slot switches on day one. In case of the Cisco Nexus 7700 2‑slot chassis, the fabric modules are not required since it uses a single I/O module. The midplane design on the 2‑, 6-, 10-, and 18-slot chassis supports flexible technology upgrades as your needs change, providing ongoing investment protection. Future fabric modules will allow higher bandwidth capabilities on the platform.

Cisco Nexus 7700 2-Slot Switch

      The Cisco Nexus 7700 2-Slot Switch, with one I/O module slots, supports up to 48 x 1 and 10 Gigabit Ethernet ports, 24 x 40 Gigabit Ethernet ports, or 12 x 100 Gigabit Ethernet ports, to meet the demands of small campus and data center deployments in a compact 3 Rack Units (RU) footprint.

      The Cisco Nexus 7700 2-Slot Switch has one dedicated half-slot supervisor.

      The Cisco Nexus 7700 2-slot chassis does not include any fabric modules as it has a single module only. The system is capable of supporting all current and future Cisco Nexus 7700 modules at full line-rate switching capacity.

      Front-to-back airflow helps ensure that the Cisco Nexus 7702 addresses the requirement for hot-aisle and cold-aisle deployments, to help provide efficient cooling.

      The system uses one fan tray for cooling. The fan tray is composed of three independent variable-speed fans that automatically adjust to the ambient temperature, helping to reduce power consumption in well-managed facilities while supporting optimum operation of the switch.

      The system supports an optional door and air filter to help ensure clean airflow through the system. The addition of the air filter satisfies Network Equipment Building Standards (NEBS) requirements.

      The Cisco Nexus 7700 2-Slot Switch can have up to two 3- or 3.5-kilowatt (KW) power supplies. The redundant power supply configuration provides more flexibility in power redundancy configuration.

      The I/O module, supervisor module, and power supplies are accessible from the front, and the fan tray is accessible from the back of the chassis.

      The I/O module, supervisor module, and power supplies are inter-changeable across all Cisco Nexus 7700 chassis.

Cisco Nexus 7700 6-Slot Switch

      The Cisco Nexus 7700 6-Slot Switch, with up to four I/O module slots, supports up to 192 x 1 and 10 Gigabit Ethernet ports, 96 x 40 Gigabit Ethernet ports, and 48 x 100 Gigabit Ethernet ports, meeting the demands of small to medium data center deployments in a compact 9 Rack Units (RU) footprint.

      The Cisco Nexus 7700 6-Slot Switch has two dedicated half-slot supervisors to provide full redundancy, stateful supervisor switchover, and hitless In-Service Software Upgrade (ISSU) capabilities.

      The Cisco Nexus 7706 has six fabric module slots to provide simultaneously active fabric channels to each of the I/O and supervisor modules. Through the parallel forwarding fabric architecture, the Cisco Nexus 7706 can achieve 10.5 Tbps of forwarding capacity or more.

      Front-to-back airflow helps ensure that the Cisco Nexus 7706 addresses the requirement for hot-aisle and cold-aisle deployments to help provide efficient cooling.

      The system uses three redundant fan trays for cooling. Each fan tray is composed of independent variable-speed fans that automatically adjust to the ambient temperature, helping reduce power consumption in well-managed facilities while helping enable optimum operation of the switch. The system also allows hot swapping of fan trays without negatively affecting the system.

      The system supports an optional door and air filter to help ensure clean airflow through the system. The addition of the air filter satisfies Network Equipment Building Standards (NEBS) requirements.

      The Cisco Nexus 7700 6-Slot Switch can have up to four 3- or 3.5-(kW) power supplies. The smaller power supply configuration provides more flexibility and greater control in power provisioning. The four power supply bays are designed for future growth.

      I/O modules, supervisor modules, and power supplies are accessible from the front, and fabric modules and fan trays are accessible from the back of the chassis.

Cisco Nexus 7700 10-Slot Switch

      The Cisco Nexus 7700 10-Slot Switch, with up to eight I/O module slots, supports up to 384 x 1 and 10 Gigabit Ethernet ports, 192 x 40 Gigabit Ethernet ports, and 96 x 100 Gigabit Ethernet ports, to meet the demands of large data center deployments.

      The Cisco Nexus 7700 10-Slot Switch has two dedicated half-slot supervisors to provide full redundancy, stateful supervisor switchover, and hitless In-Service Software Upgrade (ISSU) capabilities.

      The Cisco Nexus 7710 has six fabric module slots to provide simultaneously active fabric channels to each of the I/O and supervisor modules. Through the parallel forwarding fabric architecture, the Cisco Nexus 7710 can achieve 21 Tbps of forwarding capacity or more.

      Front-to-back airflow helps ensure that the Cisco Nexus 7710 addresses the requirement for hot-aisle and cold-aisle deployments to help provide efficient cooling.

      The system uses three redundant fan trays for cooling. Each fan tray is composed of independent variable-speed fans that automatically adjust to the ambient temperature, to help reduce power consumption in well-managed facilities while helping to enable optimum operation of the switch. The system also allows hot swapping of fan trays without negatively affecting the system.

      The system supports an optional door and air filter to promote clean airflow through the system. The addition of the air filter satisfies Network Equipment Building Standards (NEBS) requirements.

      The Cisco Nexus 7700 10-Slot Switch can have up to eight 3- or 3.5-(kW) power supplies. The smaller power supply configuration provides more flexibility and greater control in power provisioning. The eight power supply bays are designed for future growth, and most common configurations do not require the use of all power supply units for redundant power configurations.

      I/O modules, supervisor modules, and power supplies are accessible from the front, and fabric modules and fan trays are accessible from the back of the chassis.

Cisco Nexus 7700 18-Slot Switch

      The Cisco Nexus 7700 18-Slot Switch, with up to 16 I/O module slots, supports up to 768 x 1 and 10 Gigabit Ethernet ports, 384 x 40 Gigabit Ethernet ports, and 192 x 100 Gigabit Ethernet ports, to meet the demands of the largest data center deployments.

      The Cisco Nexus 7700 18-Slot Switch has two dedicated half-slot supervisors to provide full redundancy, stateful supervisor switchover, and hitless In-Service Software Upgrade (ISSU) capabilities.

      The Cisco Nexus 7700 18-Slot Switch has six fabric module slots to provide simultaneously active fabric channels to each of the I/O and supervisor modules. Through the parallel forwarding fabric architecture, the Cisco Nexus 7700 18-Slot Switch can achieve 42 Tbps of forwarding capacity or more.

      Front-to-back airflow helps ensure that the Cisco Nexus 7700 18-Slot Switch addresses the requirement for hot-aisle and cold-aisle deployments to support efficient cooling.

      The system uses three redundant fan trays for cooling. Each fan tray is composed of independent variable‑speed fans that automatically adjust to the ambient temperature, to reduce power consumption in well-managed facilities while helping to enable optimum operation of the switch. The system also allows hot swapping of fan trays without negatively affecting the system.

      The system supports an optional door and air filter to help ensure clean airflow through the system. The addition of the air filter satisfies NEBS requirements.

      The Cisco Nexus 7700 18-Slot Switch can have up to sixteen 3- or 3.5-kW power supplies. The smaller power supply configuration provides more flexibility and greater control in power provisioning. The 16 power supply bays are designed for future growth, and most common configurations do not require the use of all power supply units for redundant power configurations.

      I/O modules, supervisor modules, and power supplies are accessible from the front, and fabric modules and fan trays are accessible from the back of the chassis.

Common Components on Cisco Nexus 7700 Switches

All Cisco Nexus 7700 Switches have the following components:

      An integrated cable management system, custom designed for the 2-, 6-, 10-, and 18-slot switches, supports the cabling requirements of a fully configured system at either or both sides of the switch, providing outstanding flexibility. All system components can easily be removed with the cabling in place, providing ease of maintenance with no disruption.

      A series of LEDs at the top of the chassis (except in case of the Cisco Nexus 7700 2-slot chassis) provides a clear summary of the status of the major system components, alerting operators to the need to conduct further investigation. These LEDs report the power supply, fan, fabric, supervisor, and I/O module status.

Energy-Efficient Design

The Cisco Nexus 7700 Switches use 3.5-kW and 3-kW power supplies that are 96 and 90 percent efficient or greater, so less power is dissipated as heat, and more power is available for the system to use than with typical power supplies. These high-efficiency power supplies allow smaller power configuration and provide flexible power provisioning.

The fan trays in the switches have variable speed fans that adjust to compensate for changing thermal characteristics and use less power at typical operating conditions. Standard fan trays are included as part of the Nexus 7700 2-, 6-, 10-, and 18-slot chassis. The Nexus 7700 6-, 10-, and 18-slot chassis also support optional generation 2 fan trays. All fan trays provide NEBS compliance in combination with the rest of the components of the chassis for specific system configurations. Additionally, the generation 2 fan trays provide NEBS Level-3 acoustic compliance and short term operation at 55C for the Nexus 7700 6-, 10-, and 18-slot chassis if configured with the Nexus 7700 M3 100G I/O modules or future I/O modules.

Consolidation of multiple switches to Cisco Nexus 7700 Switches is made possible by the high density of ports on the switches combined with high-performance device virtualization, comprehensive reliability, and availability features. This consolidation capability provides multiple benefits such as reduced power, cooling, and space requirements to save on costs.

Product specifications

Table 1 lists the product specifications for the Cisco Nexus 7700 Switches.

Table 1.        Product specifications

Item

Specification

 

Cisco Nexus 7700 2-Slot Chassis

Cisco Nexus 7700 6-Slot Switch

Cisco Nexus 7700 10-Slot Switch

Cisco Nexus 7700 18-Slot Switch

Port count

48 x 10 Gbps, 24 x 40 Gbps, and 12 x 100 Gbps

192 x 10 Gbps, 96 x 40 Gbps, and 48 x 100 Gbps

384 x 10 Gbps, 192 x 40 Gbps, and 96 x 100 Gbps

768 x 10 Gbps, 384 x 40 Gbps, and 192 x 100 Gbps

Product compatibility

  Supports all Cisco Nexus 7700 switch modules except the following:
  N77-F248XP-23E
  Does not use fabric modules
  Supports all Cisco Nexus 7700 Series Supervisor and I/O modules
  Supports Cisco Nexus 7700 Series Fabric-2 modules
  Supports Cisco Nexus 7700 Series Fabric 3 modules
  Supports all Cisco Nexus 7700 Series Supervisor and I/O modules
  Supports Cisco Nexus 7700 Series Fabric-2 modules
  Supports Cisco Nexus 7700 Series Fabric 3 modules
  Supports all Cisco Nexus 7700 Series Supervisor and I/O modules
  Supports Cisco Nexus 7700 Series Fabric-2 modules

Software compatibility

Cisco NX-OS Software Release 7.2 or later

Cisco NX-OS Software Release 6.2.6 or later

Cisco NX-OS Software Release 6.2.2 or later

Cisco NX-OS Software Release 6.2.2 or later

Options

  Door air filter
  Lockable front module doors
  Door air filter
  Lockable front module doors
  Door air filter
  Lockable front module doors
  Door air filter
  Lockable front module doors
  Power supply center cable management

System forwarding capacity

No fabric modules

All I/O modules are line rate

21 Tbps

42 Tbps

83 Tbps

Max local switching capacity*

2.4 Tbps

2.4 Tbps

2.4 Tbps

1.2 Tbps

Max inter-slot switching capacity*

n/a

2.4 Tbps

2.4 Tbps

1.2 Tbps

Reliability and availability

Online insertion and removal (OIR) of redundant power supplies

OIR of all redundant components: supervisor and fabric modules, power supplies, and fan trays

OIR of all redundant components: supervisor and fabric modules, power supplies, and fan trays

OIR of all redundant components: supervisor and fabric modules, power supplies, and fan trays

MIBs

Supports Simple Network Management Protocol Version 3 (SNMPv3), v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

Supports SNMPv3, v2c, and v1 (see Cisco NX-OS Software release notes for details about specific MIB support)

Network management

Cisco Data Center Network Manager (DCNM)

Cisco Data Center Network Manager (DCNM)

Cisco Data Center Network Manager (DCNM)

Cisco Data Center Network Manager (DCNM)

Programming interfaces

  XML
  Scriptable command-line interface (CLI)
  Cisco DCNM web services
  Python
  Tool Command Language (TCL)
  Cisco IOS ® Embedded Event Manager (EEM)
  Cisco One Platform Kit (OnePK )
  OpenFlow
  XML
  Scriptable CLI
  Cisco DCNM web services
  Python
  TCL
  Cisco IOS EEM
  Cisco OnePK
  OpenFlow
  XML
  Scriptable CLI
  Cisco DCNM web services
  Python
  TCL
  Cisco IOS EEM
  Cisco OnePK
  OpenFlow
  XML
  Scriptable CLI
  Cisco DCNM web services
  Python
  TCL
  Cisco IOS EEM
  Cisco OnePK
  OpenFlow

Physical specifications

  Required rack space: 3RU
  2-slot switch: 1 dedicated supervisor module and 1 I/O module
  No fabric modules
  2 power supply slots
  Dimensions (H x W x D): 5.15 x 17.3 x 29.1 in. (13.08 x 43.9 x 73.9 cm)
  Chassis depth, including cable management and chassis doors, is 35.1 in. (89.15 cm)
  Unit is rack-mountable in a standard 19-inch (482.6-mm) EIA rack; unit is also 2-post rack-mountable
  Weight
  Chassis only: 37.5 lb (17 kg)
  Fan Tray: 13.5 lb (6.1 kg)
  Supports 3-kW AC and DC and 3.5-kW HV AC/DC power supplies
  Required rack space: 9RU
  6-slot switch: 2 dedicated supervisor modules and 4 I/O modules
  6 fabric module slots
  4 power supply slots
  Dimensions (H x W x D): 15.6 x 17.3 x 32 in. (39.62 x 43.9 x 81.3 cm)
  Chassis depth, including cable management and chassis doors, is 38 in. (96.52 cm)
  Additional depth with Generation 2 fan tray is 1.75 in. (4.5 cm)
  Unit is rack-mountable in a standard 19-inch (482.6-mm) EIA rack; unit is also 2-post rack-mountable
  Weight
  Chassis only: 145 lb (65.8 kg)
  Fabric Module: 5.6 lb (2.5 kg)
  Fan Tray: 5.3 lb (2.4 kg)
  Fan Tray (Generation 2): 7.75 lb (3.5 kg)
  Supports 3-kW AC and DC and 3.5-kW HV AC/DC power supplies
  Required rack space: 14RU
  10-slot switch: 2 dedicated supervisor modules and 8 I/O modules
  6 fabric module slots
  8 power supply slots
  Dimensions (H x W x D): 24.35 x 17.3 x 34 in. (61.85 x 43.9 x 86.4 cm)
  Chassis depth, including cable management and chassis doors, is 40 in. (101.6 cm)
  Additional depth with Generation 2 fan tray is 1.75 in. (4.5 cm)
  Unit is rack-mountable in a standard 19-inch (482.6-mm) EIA rack
  Weight
  Chassis only: 160 lb (72.6 kg)
  Fabric Module: 11 lb (5.0 kg)
  Fan Tray: 8.5 (3.9 kg)
  Fan Tray (Generation 2): 12 lb (5.4 kg)
  Supports 3-kW AC and DC and 3.5-kW HV AC/DC power supplies
  Required rack space: 26RU
  18-slot switch: 2 dedicated supervisor modules and 16 I/O modules
  6 fabric module slots
  16 power supply slots
  Dimensions (H x W x D): 45.25 x 17.3 x 35 in. (114.9 x 43.9 x 88.9 cm)
  Chassis depth, including cable management and chassis doors, is 41 in. (104.1 cm)
  Additional depth with Generation 2 fan tray is 1.75 in. (4.5 cm)
  Unit is rack-mountable in a standard 19-inch (482.6-mm) EIA rack
  Weight
  Chassis only: 300 lb (136.0 kg)
  Fabric Module: 20 lb (9.1 kg)
  Fan Tray: 13.5 lb (6.1 kg)
  Fan Tray (Generation 2): 17.75 lb (8.1 kg)
  Supports 3-kW AC and DC and 3.5-kW HV AC/DC power supplies

Environmental specifications

  Airflow direction: Front to back
  Operating temperature: 32 to 104°F (0 to 40°C)
  Operational relative humidity: 5 to 90%, noncondensing
  Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
  Seismic: Zone 4 per GR63
  Floor loading: 24 lbs per sq. ft.
  Operational vibration
  GR63, Section 5.4.2
  ETS 300 019-1-3, Class 3.1, Section 5.5
  Storage altitude: -1000 to 30,000 ft.
  Storage temperature: -40 to 158°F (-40 to 70°C)
  Storage relative humidity: 5 to 95%, noncondensing
  Heat dissipation: Maximum 6650 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration)
  Airflow direction: Front to back
  Operating temperature: 32 to 104°F (0 to 40°C)
  Operational relative humidity: 5 to 90%, noncondensing
  Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
  Seismic: Zone 4 per GR63
  Floor loading: 92 lbs per sq. ft.
  Operational vibration
  GR63, Section 5.4.2
  ETS 300 019-1-3, Class 3.1, Section 5.5
  Storage altitude: -1000 to 30,000 ft.
  Storage temperature: -40 to 158°F (-40 to 70°C)
  Storage relative humidity: 5 to 95%, noncondensing
  Heat dissipation: Maximum 26,280 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration)
  Airflow direction: Front to back
  Operating temperature: 32 to 104°F (0 to 40°C)
  Operational relative humidity: 5 to 90%, noncondensing
  Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
  Seismic: Zone 4 per GR63
  Floor loading: 122 lbs per sq. ft.
  Operational vibration
  GR63, Section 5.4.2
  ETS 300 019-1-3, Class 3.1, Section 5.5
  Storage altitude: -1000 to 30,000 ft.
  Storage temperature: - 40 to 158°F (-40 to 70°C)
  Storage relative humidity: 5 to 95%, noncondensing
  Heat dissipation: Maximum 52,500 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration)
  Airflow direction: Front to back
  Operating temperature: 32 to 104°F (0 to 40°C)
  Operational relative humidity: 5 to 90%, noncondensing
  Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
  Seismic: Zone 4 per GR63
  Floor loading: 230 lbs per sq. ft.
  Operational vibration
  GR63, Section 5.4.2
  ETS 300 019-1-3, Class 3.1, Section 5.5
  Storage altitude: -1000 to 30,000 ft.
  Storage temperature: -40 to 158°F (-40 to 70°C)
  Storage relative humidity: 5 to 95%, noncondensing
  Heat dissipation: Maximum 96,160 BTUs per hour (actual dissipation will be lower, depending on the chassis configuration)

 

Regulatory compliance

  EMC compliance
  FCC Part 15 (CFR 47) (USA) Class A
  ICES-003 (Canada) Class A
  EN55022 (Europe) Class A
  CISPR22 (International) Class A
  AS/NZS CISPR22 (Australia and New Zealand) Class A
  VCCI (Japan) Class A
  KN22 (Korea) Class A
  CNS13438 (Taiwan) Class A
  CISPR24
  EN55024
  EN50082-1
  EN61000-3-2
  EN61000-3-3
  EN61000-6-1
  EN300 386

Environmental standards

  NEBS criteria levels *
  SR-3580 NEBS Level 3 (GR-63-CORE and GR-1089-CORE)
  Verizon NEBS compliance *
  Telecommunications Carrier Group (TCG) checklist
  Century Link NEBS requirements *
  Telecommunications Carrier Group (TCG) checklist
  ATT NEBS requirements *
  ATT TP76200 level 3
  ETSI *
  ETSI 300 019-2-1, Class 1.2 storage
  ETSI 300 019-2-2, Class 2.3 transportation
  ETSI 300 019-2-3, Class 3.2 stationary use

* Validation in progress

Safety

  UL/CSA/IEC/EN 60950-1
  AS/NZS 60950

Warranty

Cisco Nexus 7700 Switches come with the standard Cisco 1-year limited hardware warranty

* Based on Nexus 7700 Series Fabric 3 Modules for the 6-slot and 10-slot chassis. Based on Nexus 7700 Fabric 2 Modules for the 18-slot chassis.

Software requirements

All Cisco Nexus 7000 Series Switches are supported by Cisco NX-OS Software and Cisco Data Center Network Manager. Check Cisco NX-OS Software release notes (http://www.cisco.com/c/en/us/support/switches/nexus-7000-series-switches/products-release-notes-list.html) and Cisco DCNM release notes (http://www.cisco.com/c/en/us/support/cloud-systems-management/prime-data-center-network-manager/products-release-notes-list.html) for details.

For the latest information about recommended releases, see: http://www.cisco.com/en/US/docs/switches/datacenter/sw/nx-os/recommended_releases/recommended_nx-os_releases.html.

Ordering information

To place an order, visit the Cisco Ordering webpage. To download software, visit the Cisco Software Center. Table 2 provides ordering information.

Table 2.        Ordering information

Product Name

Part Number

System

Cisco Nexus 7700 Switches 2-Slot Chassis, including fan tray, no power supply

N77-C7702

Cisco Nexus 7700 Switches 2-Slot Chassis, including fan tray, no power supply spare

N77-C7702=

Cisco Nexus 7700 Switches 2-Slot Fan Tray

N77-C7702-FAN

Cisco Nexus 7700 Switches 2-Slot Fan Tray Spare

N77-C7702-FAN=

Cisco Nexus 7700 Switches 6-Slot Chassis, including fan trays, no power supply

N77-C7706

Cisco Nexus 7700 Switches 6-Slot Chassis, including fan trays, no power supply spare

N77-C7706=

Cisco Nexus 7700 Switches 6-Slot Fan Tray

N77-C7706-FAN

Cisco Nexus 7700 Switches 6-Slot Fan Tray Spare

N77-C7706-FAN=

Cisco Nexus 7700 Switches 6-Slot Fan Tray (Generation 2)

N77-C7706-FAN-2

Cisco Nexus 7700 Switches 6-Slot Fan Tray (Generation 2) Spare

N77-C7706-FAN-2=

Cisco Nexus 7700 Switches 10-Slot Chassis, including fan trays, no power supply

N77-C7710

Cisco Nexus 7700 Switches 10-Slot Chassis, including fan trays, no power supply spare

N77-C7710=

Cisco Nexus 7700 Switches -10-Slot Fan Tray

N77-C7710-FAN

Cisco Nexus 7700 Switches -10-Slot Fan Tray Spare

N77-C7710-FAN=

Cisco Nexus 7700 Switches -10-Slot Fan Tray (Generation 2)

N77-C7710-FAN-2

Cisco Nexus 7700 Switches -10-Slot Fan Tray (Generation 2) Spare

N77-C7710-FAN-2=

Cisco Nexus 7700 Switches 18-Slot Chassis, including fan trays, no power supply

N77-C7718

Cisco Nexus 7700 Switches 18-Slot Chassis, including fan trays, no power supply spare

N77-C7718=

Cisco Nexus 7700 Switches -18-Slot Fan Tray

N77-C7718-FAN

Cisco Nexus 7700 Switches -18-Slot Fan Tray Spare

N77-C7718-FAN=

Cisco Nexus 7700 Switches -18-Slot Fan Tray (Generation 2)

N77-C7718-FAN-2

Cisco Nexus 7700 Switches -18-Slot Fan Tray (Generation 2) Spare

N77-C7718-FAN-2=

Cisco Nexus 7700 Switches 2-Slot Accessories

Cisco Nexus 7702 Center Mount Kit (for 2-post rack mounting)

N77-C7702-CMK

Cisco Nexus 7702 Center Mount Kit (for 2-post rack mounting) Spare

N77-C7702-CMK=

Cisco Nexus 7702 Front Door Air Filter Spare

N77-C7702-FDAFLT=

Cisco Nexus 7702 Front Air Filter Kit Spare

N77-C7702-AFLT=

Cisco Nexus 7702-Rack Mount Kit Spare

N77-C7702-RMK=

Cisco Nexus 7702 Cable Management Kit Spare

N77-C7702-CAB=

Cisco Nexus 7702 Front Door Kit Spare

N77-C7702-FDK=

Cisco Nexus 7702 Accessory Kit Spare

N77-C7702-ACC-KIT=

Cisco Nexus 7702 Shipping Package Spare

N77-C7702-SHPPKG=

Cisco Nexus 7700 Switches 6-Slot Accessories

Cisco Nexus 7706 Center Mount Kit (for 2-post rack mounting)

N77-C7706-CMK

Cisco Nexus 7706 Center Mount Kit (for 2-post rack mounting) Spare

N77-C7706-CMK=

Cisco Nexus 7706 Front Door Air Filter Spare

N77-C7706-FDAFLT=

Cisco Nexus 7706 Front & Side Air Filter

N77-C7706-AFLT

Cisco Nexus 7706 Front & Side Air Filter Spare

N77-C7706-AFLT=

Cisco Nexus 7706-Rack Mount Kit Spare

N77-C7706-RMK=

Cisco Nexus 7706 Cable Management and Top LED Kit Spare

N77-C7706-CAB-TOP=

Cisco Nexus 7706 Front Door Kit

N77-C7706-FDK

Cisco Nexus 7706 Front Door Kit Spare

N77-C7706-FDK=

Cisco Nexus 7706 Bottom Support Kit Spare

N77-C7706-BSK=

Cisco Nexus 7706 Accessory Kit Spare

N77-C7706-ACC-KIT=

Cisco Nexus 7706 Shipping Package Spare

N77-C7706-SHPPKG=

Cisco Nexus 7700 Switches 10-Slot Accessories

Cisco Nexus 7710 Front Door Air Filter Spare

N77-C7710-FDAFLT=

Cisco Nexus 7710 Front & Side Air Filter

N77-C7710-AFLT

Cisco Nexus 7710 Front & Side Air Filter Spare

N77-C7710-AFLT=

Cisco Nexus 7710-Rack Mount Kit Spare

N77-C7710-RMK=

Cisco Nexus 7710 Cable Management and Top LED Kit Spare

N77-C7710-CAB-TOP=

Cisco Nexus 7710 Front Door Kit

N77-C7710-FDK

Cisco Nexus 7710 Front Door Kit Spare

N77-C7710-FDK=

Cisco Nexus 7710 Bottom Support Kit Spare

N77-C7710-BSK=

Cisco Nexus 7710 Accessory Kit Spare

N77-C7710-ACC-KIT=

Cisco Nexus 7710 Shipping Package Spare

N77-C7710-SHPPKG=

Cisco Nexus 7700 Switches 18-Slot Accessories

Cisco Nexus 7718 Power Cable Management

N7K-C7718-PCM

Cisco Nexus 7718 Power Cable Management Spare

N7K-C7718-PCM=

Cisco Nexus 7718 Front Door Air Filter Spare

N77-C7718-FDAFLT=

Cisco Nexus 7718 Front & Side Air Filter

N77-C7718-AFLT

Cisco Nexus 7718 Front & Side Air Filter Spare

N77-C7718-AFLT=

Cisco Nexus 7718-Rack Mount Kit Spare

N77-C7718-RMK=

Cisco Nexus 7718 Cable Management and Top LED Kit Spare

N77-C7718-CAB-TOP=

Cisco Nexus 7718 Front Door Kit

N77-C7718-FDK

Cisco Nexus 7718 Front Door Kit Spare

N77-C7718-FDK=

Cisco Nexus 7718 Bottom Support Kit Spare

N77-C7718-BSK=

Cisco Nexus 7718 Accessory Kit Spare

N77-C7718-ACC-KIT=

Cisco Nexus 7718 Shipping Package Spare

N77-C7718-SHPPKG=

Blank Panel Covers

Cisco Nexus 7700 Switches Supervisor Blank Slot Cover

N77-SUP-BLANK

Cisco Nexus 7700 Switches Supervisor Blank Slot Cover Spare

N77-SUP-BLANK=

Cisco Nexus 7700 Switches Module Blank Slot Cover

N77-MODULE-BLANK

Cisco Nexus 7700 Switches Module Blank Slot Cover Spare

N77-MODULE-BLANK=

Cisco Nexus 7700 Switches 3 KW Power Supply Blank Slot Cover with Handle

N77-3KPS-BLANK-H

Cisco Nexus 7700 Switches 3 KW Power Supply Blank Slot Cover with Handle Spare

N77-3KPS-BLANK-H=

 

Cisco environmental sustainability

Information about Cisco’s environmental sustainability policies and initiatives for our products, solutions, operations, and extended operations or supply chain is provided in the “Environment Sustainability” section of Cisco’s Corporate Social Responsibility (CSR) Report.

Reference links to information about key environmental sustainability topics (mentioned in the “Environment Sustainability” section of the CSR Report) are provided in the following table:

Sustainability topic

Reference

Information on product material content laws and regulations

Materials

Information on electronic waste laws and regulations, including products, batteries, and packaging

WEEE compliance

Cisco makes the packaging data available for informational purposes only. It may not reflect the most current legal developments, and Cisco does not represent, warrant, or guarantee that it is complete, accurate, or up to date. This information is subject to change without notice.

Service and Support

Cisco offers a wide range of services to help accelerate your success in deploying and optimizing the Cisco Nexus 7700 in your data center. Our innovative services are delivered through a unique combination of people, processes, tools, and partners, and are focused on helping you increase operation efficiency and improve your data center network. Cisco Advanced Services use an architecture-led approach to help you align your data center infrastructure with your business goals and provide long-term value. Cisco Smart Net Total Care Service helps you resolve mission-critical problems with direct access at any time to Cisco network experts and award-winning resources. With this service, you can take advantage of the Cisco Smart Call Home service capability, which offers proactive diagnostic information and real-time alerts for your Cisco Nexus 7700 switches. Spanning the entire network lifecycle, Cisco Services helps increase investment protection, optimize network operations, provide migration support, and strengthen your IT expertise. For more information about Cisco Data Center Services, visit http://www.cisco.com/go/dcservices.

Cisco Capital

Flexible payment solutions to help you achieve your objectives

Cisco Capital makes it easier to get the right technology to achieve your objectives, enable business transformation and help you stay competitive. We can help you reduce the total cost of ownership, conserve capital, and accelerate growth. In more than 100 countries, our flexible payment solutions can help you acquire hardware, software, services and complementary third-party equipment in easy, predictable payments. Learn more.

For more information

For more information about the Cisco Nexus 7700 switches, visit the product homepage at http://www.cisco.com/go/nexus or contact your account representative.

Learn more